7/21/2019 Cooper
http://slidepdf.com/reader/full/cooper-56e064ac34cb3 1/8
Description:Cooper Wheelock’s PA/VA Voice System operates in conjunctionwith the Cooper 6000 Fire Alarm Control Panel (FACP) to pro-vide automatic response in a building for emergencies.
The system includes all necessary features to provide and effec-tive evacuation system. The Cooper Wheelock PA/VA can beeasily customized for conguration and applications in any high
rise specication.User friendly controls allow the Fire Department Authority toeasily take command for evacuation or relocation procedures oremergencies. Emergency response teams can monitor the situ-ation until professional help arrives at the scene.
The Cooper Wheelock PA/VA system includes capacity for 6channels simultaneous audio, exibility provides for public ad-dress announcements, stay-in-place, evacuation, or automaticmessages.
Warden Stations and Fire Fighters telephones can be conguredas required, Area of Rescue can reassure physically challengedoccupants that help is being dispatched to their location.
Public Address/Voice Announcement High Rise Evacuation System
• Works with Analog/Addressable and Microprocessor basedFire Alarm Panels
• Easy Installation and Operation
• Fully Supervised
• Natural Sound Voice Recordings
• Modular Systems - components added as needed• Integrated 2 Channel Digital Message Repeater
• True Multiplex 6 Channel Distributed Audio
• Live Microphone Page to any zone
• Fast RS-485 Communications Protocol
• Integrated Fire Phone, Area of Rescue and Fan & DamperControl capability
• Up to 4 Minute Message Capability
• Works with 12VDC or 24VDC Fire Alarm Panel
• 3 Minute Message Restart on Microphone Key
• Built in Alarm and Alert Signals
Features:
System CongurationBasic System Includes:
• Master Panel
• Master Mic Control
• 16 switch control points
• Dual Channel DMR
• High speed communication loop
• Distributed Panel (HMX)
• 4 Output Zones (may be congured for 8)
• Dual Channel Audio Interface
• Dual Channel Amplication
Optional:• Integrated Fire Phone
• Area-of-Rescue
• Number of distributed panesl to be detereminedby building specications
• Maximim System Conguration - Up to 250
Distributed Panels (HMX) and up to 1000switch points
Master Panel
7/21/2019 Cooper
http://slidepdf.com/reader/full/cooper-56e064ac34cb3 2/8
Distributed panel congurationsHMX-MP16Master Panel, 16 Switch Control
HMX-MP32Master Panel, 32 Switch Control
HMX-MP48
Master Panel, 48 Switch ControlHMX-MP64Master Panel, 64 Switch Control
HMX-MP80Master Panel, 80 Switch Control
HMX-MP96Master Panel, 96 Switch Control
HMX-MP16/PMaster Panel, 16 Switch Control, Master Fire Phone
HMX-MP32/PMaster Panel, 32 Switch Control, Master Fire Phone
HMX-MP64/PMaster Panel, 64 Switch Control, Master Fire Phone
HMX-MP80/PMaster Panel, 80 Switch Control, Master Fire Phone
HMX-MP96/PMaster Panel, 96 Switch Control, Master Fire Phone
System CongurationBasic System Includes:
• Master Panel
• Master Mic Control
• 16 switch control points
• Dual Channel DMR• High speed communication loop
Optional:• Integrated Fire Phone
• Area-of-Rescue
• Maximim System Conguration - Up to 1000Monitor and Control Points
Technical SpecicationsPrimary Power 220 VACBattery Power 24 VDCElectrical Ratings All circuits @ 24 VDC
Communications Bus RS-485 Standard 1M Bauddata rate, category 5 cable
Voltage 5V peak-to-peak maxCurrent 50mA maxImpedence 120 OhmsFrequency 1.024 MHzBackbox dimensions 36.8 W x 68.6 H x 10.2 D cmColor Cool Grey 1 C
Master Panel Standby Alarm
MX-DCC 80mA 80mAMX-ASC 30mA 30mA
MX-MFP 10mA 10mA
MX-SSC 25mA 25mAMX-SLC 6mA 6mAMX-MMC 45mA 45mAMX-IOI 20mA 20mA
Panel optionsCards may be added as job requirements demand
HMX-MP16Master Panel, 16 Switch Control
HMX-MP32Master Panel, 32 Switch Control
HMX-MP48Master Panel, 48 Switch Control
HMX-MP64Master Panel, 64 Switch Control
HMX-MP80Master Panel, 80 Switch Control
HMX-MP96
Master Panel, 96 Switch ControlHMX-MP16/PMaster Panel, 16 Switch Control, Master Fire Phone
HMX-MP32/PMaster Panel, 32 Switch Control, Master Fire Phone
HMX-MP64/PMaster Panel, 64 Switch Control, Master Fire Phone
HMX-MP80/PMaster Panel, 80 Switch Control, Master Fire Phone
HMX-MP96/PMaster Panel, 96 Switch Control, Master Fire Phone
Master Panel
7/21/2019 Cooper
http://slidepdf.com/reader/full/cooper-56e064ac34cb3 3/8
Master PanelPublic Address/Voice Announcement High Rise Evacuation System
In the Master Panel systemcomponents are mounted to aremovable back plate. The doorand front panel are removable.This enables eld wiring to beinstalled cleanly.Connections to the User Interfacecomponents (Switch/LED banks,Mic/System control and MasterFire Phone) is accomplished withribbon cables. The front panelmounts separately on a continuoushinge so once installed the accessfor system programming is easilyaccommodated.
HMX-MP64P Master Panel - Ribbon Cable Connection Detail
NetComm Loop Wiring (Style 4)
NetComm Loop Wiring (Style 7)
7/21/2019 Cooper
http://slidepdf.com/reader/full/cooper-56e064ac34cb3 4/8
7/21/2019 Cooper
http://slidepdf.com/reader/full/cooper-56e064ac34cb3 5/8
7/21/2019 Cooper
http://slidepdf.com/reader/full/cooper-56e064ac34cb3 6/8
Distribution PanelPublic Address/Voice Announcement High Rise Evacuation System
Description:ooper Wheelock’s PA/VA Voice System operates in conjunction
with the Cooper 6000 Fire Alarm Control Panel (FACP) to pro-ide automatic response in a building for emergencies.
he system includes all necessary features to provide and effec-ve evacuation system. The Cooper Wheelock PA/VA can be
asily customized for conguration and applications in any highse specication.
User friendly controls allow the Fire Department Authority toasily take command for evacuation or relocation procedures ormergencies. Emergency response teams can monitor the situ-tion until professional help arrives at the scene.
he Cooper Wheelock PA/VA system includes capacity for 6hannels simultaneous audio, exibility provides for public ad-ress announcements, stay-in-place, evacuation, or automatic
messages.
Warden Stations and Fire Fighters telephones can be congureds required, Area of Rescue can reassure physically challengedccupants that help is being dispatched to their location.
• Works with Analog/Addressable and Microprocessor basedFire Alarm Panels
• Easy Installation and Operation
• Fully Supervised
• Natural Sound Voice Recordings
• Modular System - components added as needed
• Integrated 2 Channel Digital Message Repeater
• True Multiplex 6 Channel Distributed Audio
• Live Microphone Page to any zone
• Fast RS485 Communications Protocol
• Integrated Fire Phone, Area of Rescue and Fan & DamperControl capability
• Up to 4 Minute Message Capacity
• Works with 12VDC or 24VDC Fire Alarm Panel
• 3 Minute Message Restart on Microphone Key
• Built-In Alarm and Alert Sounds
Features:
Distributed panel congurationsHMX-DPS25Single Channel, 25W
HMX-DPS50Single Channel, 50W
HMX-DPS100Single Channel, 100W
HMX-DPS200
Single Channel, 200WHMX-DPS25/PSingle Channel, 25W, Fire Phone
HMX-DPS50/PSingle Channel, 50W, Fire Phone
HMX-DPS100/PSingle Channel, 100W, Fire Phone
HMX-DPS200/PSingle Channel, 200W, Fire Phone
HMX-DP25Double Channel, 25W
HMX-DP50Double Channel, 50W
HMX-DP100Double Channel, 100W
HMX-DP25/PDouble Channel, 25W, Fire Phone
HMX-DP50/PDouble Channel, 50W, Fire Phone
HMX-DP100/PDouble Channel, 100W, Fire Phone
Panel optionsCards may be added as job requirements demand
HMX-MBK Motherboard Relay CardExpands MX-MBR output 8 Class B or 4 Class A cir-cuitsHMX-FPI Phone Interface CardIncluded in /P panels, up to 3 additional cards may beadded
HMX-FPO Fire Phone Output CardUsed with additional MX-FPI’s
HMX-AMIIncluded with basic panel, additional cards give theability to control multiple modules or accommodate full6 channel operation
Specications are subject to change without notice. Specications areprovided for information only and no responsibility is assumed by CooperWheelock.
7/21/2019 Cooper
http://slidepdf.com/reader/full/cooper-56e064ac34cb3 7/8
ystem CongurationBasic System Includes:
• Distribution Panel (HMX-DP)
• 4 Output Zones (may be congured for 8)
• Dual Channel Audio Interface
• Dual/Single Channel Amplication
Optional:• Integrated Fire Phone
• 4 Circuits expandable to 8, 12 or 16
• Area-of-Rescue
• Maximim System Conguration - Up to 256Distributed Panels (HMX-DP)
Technical SpecicationsPrimary Power 220 VACBattery Power 24 VDCBattery Charging Maximum charging current from CWX-25/50 is 800mAMax. Battery Size 17Ah. for CWX-25/50, 24Ah for CWx-100Electrical Ratings All circuits @ 24 VDC
Communications Bus RS-485 Standard 1M Baud data rate, category 5 cable
Voltage 5V peak-to-peak maxCurrent 50mA maxImpedence 120 OhmsFrequency 1.024 MHzBackbox dimensions 36.8 W x 68.6 H x 10.2 D cmColor Cool Grey 1 C
Master Panel Standby Alarm
MX-DCC 55mA 55mAMX-MBR 10mA 55mAMX-AMI 10mA 10mAMX-FPI 13mA 135mA
Distribution PanelPublic Address/Voice Announcement High Rise Evacuation System
Public Address/Voice Announcement Fire Phone Equipment
ire Phone accessories give the Cooper Wheelock PA/VAystem two way communication capability.
ire Phone Jacks are mounted on a single gang plate.
ixed telephone and warden stations are available in Sur-ace/Semi-Flush cabinet with a Thumb Turn latch.
Ordering InformationMX-FJ Telephone Jack SG PlateBrushed Stainless Steel Single Gang Plate
MX-FH Portable HandsetColor - Red(6 mount in MX-TC cabinet)
MX-TC Telephone CabinetHolds 6 MX-FH Portable HandsetCabinet: Charcoal Gray - std. -R Red(Surface/Semi-Flush Mount/Key 27 x 14-1/2 x 4”)
MX-FS Fire Phone StationCoil cord / Thumb Turn LatchCabinet: Red(Surface/Semi-Flush Mount 12-3/4 x 7-1/4 x 3-3/4”)
MX-WS Armored Cable / Thumb Turn LatchCabinet: Red(Surface/Semi-Flush Mount 12-3/4 x 7-1/4 x 3-3/4”)
7/21/2019 Cooper
http://slidepdf.com/reader/full/cooper-56e064ac34cb3 8/8
UL®73 Branchport Avenue
ong Branch, NJ 07740hone: (800) 631-2148ax: (732) 222-2588
www.cooperwheelock.com
WE ENCOURAGE AND SUPPORT NICET CERTIFICATION3 YEAR WARRANTY
Made in USA
Evac System 01/07
Table 1: Average RMS CurrentE70/E90SpeakerStrobes
E70 Strobe Current - Wall Mount E90 Strobe Current - Ceiling Mount
241575W 24MCW 24MCWH 24MCC 24MCCH
1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd
24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270
UL max* 0.090 0.060 0.092 0.165 0.220 0.300 .0420 0.065 0.105 0.189 0.249 0.300 0.420
Table 2: E70/E90 UL Reverberant dBA @ 10 Feet**
watts 1/8 1/4 1/2 1 2
E Speaker 77 81 83 86 89
E Speaker Strobe 76 80 82 85 88
**dBA ratings are based on testing under UL Standard 1480.
* RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range(16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the maxcurrent is usually at the maximum listed voltage (33v for 24v units). For unltered FWR ratings, see installation instructions.
Model OrderCode
WallMount
CeilingMount
Strobe Sync w/SM, DSM orPS-24-8MC
StrobeCandela
ModelColorRED
ModelColorWhite
ModelColor Nickel
Mounting Op-tions
Agency Approvals
UL MEA CSFM FM BFP
70-24MCW-FR 9022 X - X 15/30/75/110 X - - L,O,P,Q,R,U,Y X X X X X
70-24MCW-FW 9023 X - X 15/30/75/110 - X - L,O,P,Q,R,U,Y X X X X X
70-24MCW-FN 3099 X - X 15/30/75/110 - - X Q,U X X X X X
70-241575W-FR 7871 X - X 15 (75 on Axis) X - - L,O,P,Q,R,U,Y X X X X X
70-241575W-FW 7876 X - X 15 (75 on Axis) - X - L,O,P,Q,R,U,Y X X X X X
70-241575W-FN 3100 X - X 15 (75 on Axis) - - X L,O,P,Q,R,U,Y X X X X X70-R 7866 X X - - X - - Q,U X X X X X
70-W 7868 X X - - - X - Q,U X X X X X
70-N 3108 X X - - - - X Q,U X X X X X
70-24MCWH-FR 3470 X - X 135/185 X - - L,O,P,Q,R,U,Y X X X X *
70-24MCWH-FW 3474 X - X 135/185 - X - L,O,P,Q,R,U,Y X X X X *
70-24MCWH-FN 0059 X - X 135/185 - - X Q,U X X X X *
90-24MCC-FW 3166 - X X 15/30/75/95 - X - Q,U,V X X X X *
90-24MCC-FR 3165 - X X 15/30/75/95 X - - Q,U,V X X X X *
90-24MCC-FN 3185 - X X 15/30/75/95 - - X Q,U,V X X X X *
90-W 7869 X X - - - X - Q,U,V X X X X X
90-R 7867 X X - - X - - Q,U,V X X X X X
90-N 3109 X X - - - - X Q,U,V X X X X X
90-24MCCH-FW 3471 - X X 115/177 - X - Q,U,V X X X X *
90-24MCCH-FR 3481 - X X 115/177 X - - Q,U,V X X X X *
90-24MCCH-FN 0062 - X X 115/177 - - X Q,U,V X X X X *
Low Prole Speakers & Speaker Strobes
Description:Series E Speakers and Speaker Strobes aredesigned for high effeciency sound output withfield selectable input voltage (25/75 VRMS)and field selectable taps from 1/8 to 2 watts.
trobe Options:• Single Candela Wall 1575
• Multi-candela 15/30/75/110 (wall)or 15/30/75/95 (ceiling)