ConventionalFire Alarm Systems
8/9/2019 Conventional Catalogue
2/44
Contents
Introduction 3-7
Premier SX Conventional
Fire Alarm Panel 8
Premier Elite Conventional
Fire Alarm Panel 9
Premier Conventional Repeater Panel 10
Premier M Plus 8-24 ZoneConventional Fire Alarm Panel 11
Premier M Plus Repeater Panel 12
Premier 48 M Plus 24-48 Zone
Conventional Fire Alarm Panel 13
Premier 48 M Plus Repeater Panel 14
Premier MX ConventionalFire Alarm Panel 15
Fyreye Extra Conventional
Optical Smoke Detector 16
Fyreye Extra Conventional Rate of
Rise and Fixed Heat Detectors 17
Fyreye Extra Conventional
Opto-Heat Detector 18
Fyreye Conventional
Ultra-Violet Flame Detector 19
Fyreye Conventional Detector Bases 20
Zeta Remote LED Indicator 21
Fyreye 50 & 100m Reective Beam
Smoke Detector 22-23
Fyreye 50 & 100m Auto-aligning Beam
Smoke Detector Systems 50 & 100m 24-25
Zeta UV/IR Optical Flame Detectors 26-27
Zeta Conventional Manual Call Points 28
Zeta Conventional
Weatherproof Call Point 29
Zeta Conventional Explosion Proof
Manual Call Point 30
Miditone ConventionalElectronic Sounder 31
Miditone Conventional Combined
Electronic Sounder & Flasher 32
Securetone Conventional
Electronic Sounder 33
Secure Light Xenon Flasher 34
Maxitone Conventional Sounder and
Combined Sounder & Flasher 35
Zeta Conventional Fire Alarm Bells 36
Zeta Flame Proof Siren 37
Zeta Flame Proof Gong Bell 38
Zeta Magnetic Door Holders 39
Zeta Duct Unit 40
Premier Power Pack EN 54-4 Power
Supply with LCD Screen 41
Batteries 42
8/9/2019 Conventional Catalogue
3/44
Introduction
Zeta Alarm Systems, a trading name of GLT Exports Ltd, was founded
in 1985 and is a privately held UK manufacturer of Fire Alarm, GasDetection and Emergency Systems.
Our brand name is well known throughout the industry and is acclaimed in over forty
countries worldwide. We are currently represented in the UK, Europe, Africa, theMiddle East, Southern Asia & South America and this list continues to grow.
Complete System Supplier
To meet the requirements of our ever-changing market,
we pride ourselves on being a complete systemsupplier. This means our customers can rely on us for
their entire system requirements.
One of the main advantages of using a complete system
supplier, compared with a component supplier, is that
system wide compatibility is assured and there is one
point of contact.
Marketing our products as systems has played a vital
role in our worldwide success.
The Future
Our continued inward investment and constant
endeavour to offer the very best products is recognisedby our increased turnover and prot margin year-on-
year. Our mission is to support our existing & future
customers by providing them with the highest qualityproducts, at the most competitive prices.
Customer Support & Product Warranty
We value our customers greatly and to ensure they have
the best experience we have a dedicated support team
who are able to assist with sales, technical or logistical
queries.
Our products carry a full 24 month manufacturers’guarantee from the date of purchase. Our networkof authorised agents is fully trained on the use of our
products and will provide a helpful & friendly service.
Research & Development
As with all electronic equipment there is an ever
present drive to manufacture products that areincreasingly effective whilst becoming more cost
sensitive. To meet this objective we spend a signicantpercentage of our prots on the continued development
of products, whether it be introducing new items, or
improving existing ones. We have a team of engineers &
designers all of whom have vast industry knowledge &
experience.
As a manufacturer we always follow the market needs
closely to evaluate how we should adapt our product
range. This, combined with welcomed customer
feedback, has proved to be a successful formula for
meeting the current and future industry needs.
Statement Of Quality Policy
We maintain a Quality System, which conforms to BS EN
ISO9001:2008. We are committed, where applicable,
to manufacture in compliance with all appropriate
legislation & regulatory requirements.
3
8/9/2019 Conventional Catalogue
4/44
Fire Detection &Alarm Systems BS5839
Risk AssessmentThe ‘Fire precautions (Workplace) Regulations’ require
any business employing ve or more persons to hold a
written ‘Fire Risk Assessment’ and ‘Emergency Plan’.
This must be periodically reviewed.
The local re brigade can enforce compliance, and
close any building that does not meet this act.
In the event of a re in a building without a written
‘Fire Risk Assessment’, those responsible may face nes
and imprisonment, and/or private litigation.
What the law requires you to do:
Complete a re risk assessment for your work
place (considering all employees, the public,
disabled people and people with special needs).
Identify and record any signicant ndings or
persons at risk.
Provide and maintain re precautions.
Provide information, instruction and training.
Nominate persons responsible to implementyour emergency plan.
Consult employees about the above nominations
and your proposals to improve re precautions.
Inform other employees who may have work
places in the building about any signicant risks
which may affect their safety and co-operate with
them to reduce/control these risks.
If you are not an employer, but control premises
which contain more than one workplace, you are
responsible for complying with re regulations.
You must establish a suitable means of
contacting the emergency services.
Your employees must co-operate to ensure the
workplace is safe from re and its effects.
Introduction to FireAlarm Systems
Fire alarm systems are used to detect are, and to signal a warning alarm to the
appropriate source.
In general, there are 3 types of system;
1. Manual Fire Alarm Systems – which rely on manualcall points to signal an alarm
2. Life Protection Fire Alarm Systems – these aredesigned to protect the occupants of a building
3. Property Protection Fire Alarm Systems – theseare designed to protect buildings
The warning may be simply ringing re alarm sirens,
however if a building is likely to be unoccupied, it may
be more appropriate to signal to a monitoring station,
or at least send a message to the building owner via
telephone.
8/9/2019 Conventional Catalogue
5/44
If the total oor area is greater than300m2:
The maximum area for a zone is 2000m2
If a stairwell (or similar) extends beyond one oor itshould be a separate zone.
If a zone covers more than one re compartmentthen the zone boundaries should follow thecompartment boundaries.
The search distance within the zone in order toascertain the position of the re should not exceed60m. Remember that the use of Remote Indicatorlamps may help to reduce the distance travelled.
If a building is divided between occupiers, zonesmust not be shared between them.
System ZoningInformation
60m Max.
Manual Call PointsA ‘Manual Call Point’ is a device which enables
personnel to raise an alarm in the event of a re
incident by pressing a frangible element to activate the
alarm system.
Manual Call Points should be installed at a height of
1.2m above oor level at easily accessible, conspicuous
positions, on exit routes, at the entry oor landings of
staircases and at all exits to the open air.
Manual Call Points should be spaced so that one may
always be found within a maximum distance of 45m
apart or 25m for disabled person.
1.2m - 1.4m
45m Max. or25m Max. for disabled person
The following guide lines should be observed:
If the total oor area of the building is less
than 300m2 then the building needs only one zone,
regardless of the number of storeys.
In order to aid identication of the source of a possible
re, the protected building should be divided into
‘zones’. When deciding on a suitable zoning scheme
for a building, consideration should be given to the
size, any existing re routines, escape routes, zone
accessibility, and structural re compartmentation.
5
8/9/2019 Conventional Catalogue
6/44
Detector Information
Automatic Detectors
When deciding on the type of detector to be used in any area it is important to remember that the detector has to
discriminate between a genuine re and the normal conditions existing therein.
Smoke Detectors
In open spaces under at horizontal ceilings, every
point should lie within 7.5m of a smoke detector.
Smoke detection should be generally avoided in the
following areas to avoid unwanted alarms. They shouldbe protected by means of other detectors such as heat
detectors.
Contamination in dusty areas may cause unwanted
alarms and reduce the life of the detector.
Damp or humid conditions such as showers, bathrooms
and external areas should be avoided as the water
vapour may cause unwanted alarms and reduce the life
of the detector.
Detectors should not be mounted where gases, vapours
or fumes are present.
Detectors should never be used at low temperature
where ice or condensation can affect detector
sensitivity.
Kitchens, garages, welding shops and boiler houses
should generally be avoided.
5.3m
10.6m
112m²
(10.6m x
10.6m)
7.5m
Room
boundary
Heat Detectors General
In open spaces under at horizontal ceilings, every
point should lie within 5.3m of a heat detector.
Heat detectors are designed to either detect a
rapid rise in temperature or to operate at a xedtemperature. Although they provide a slower response
time than smoke detectors they do provide a method of
protection for areas where smoke detectors cannot be
used.
Heat detectors should not be used for the protection of
life or where extensive property loss may be expected.
‘Rate of Rise’ Heat Detectors
‘Rate of Rise’ heat detectors respond to both rapid
increases of temperature and to xed top temperature.
‘Fixed Temperature’ Heat Detectors
Fixed temperature heat detectors are available with
different temperature settings, and are normally
installed in kitchens, boiler rooms, etc.
3.8m
7.5m
56.3m²
(7.5m x
7.5m)
5.3m
Room
boundary
8/9/2019 Conventional Catalogue
7/44
Fire Alarm SoundersFire Alarm Sounders should be installed throughout the
building with an even distribution, to generally provide
a minimum sound level of 65dB(A) or 5dB(A) above any
background noise which is likely to persist for more
than 30 seconds.
Where the alarm may have to arouse sleeping persons
e.g. Hotel bedrooms, nursing homes, etc, a minimum
sound level of 75dB(A) is required, at the bed head with
all the doors shut.
All re alarm sounders in a building should produce the
same sound, distinct from any other audible warning
devices in the building.
Where re alarm sounders are required in extremely
noisy areas e.g. Machine shops, it may be necessary to
install additional ‘Visual Indication Beacons’.
65dB(A)@ 500Hz - 1000Hz
+5dB(A)@ 500Hz - 1000Hz
Background noise
75dB(A)
Detection In Apex RoofsIf the ceiling is pitched or sloping, smoke will tend
to rise towards the highest point (apex) of the roof,
therefore detection should be placed in the apex. As
the slope tends to reduce the delay before smoke or
heat reaches the detectors, it is permissible to use a
greater spacing between the detectors mounted there.
Limits of Ceiling Height
Small Apex= Standard Spacing
Apex
600mm
SmokeDetector
Large Apex= Extended Spacing
Cabling
The operation of a Fire Alarm and Detection
System’ depends on the cabling and connections
between the components. It is essential that
connection between Manual Call Points and
Detectors function correctly when they are
operated.
Cables within the system are required to functioncorrectly for signicant periods after being
attacked by re. These include the power supply
cables to the control panel, the detection circuits
and the re alarm sounder circuits. Thus the
cables chosen must be correctly rated to withstand
these conditions.
7
8/9/2019 Conventional Catalogue
8/44
Premier SX Conventional Fire Alarm Panel(NPSX1, NPSX2, NPSX4, NPSX6, NPSX8)
The Premier SX control panel range is available
in 1, 2, 4, 6 and 8 zones, housed in a light grey
ame retardant ULV0 enclosure, designed to
meet modern architectural surroundings, with
a removable hinged door.
The Premier SX has been designed with ease of
installation in mind, in addition to the robust electronic
design expected from Zeta Alarm Systems.
Model NPSX1 NPSX2 NPSX4 NPSX6 NPSX8
Part No. 37-050 37-051 37-052 37-053 37-054
Mains Voltage 230V AC +10% / -15% @ 50/60Hz
System Voltage 24V DC (nominal)
Zone Voltage 21V DC (nominal)Sounder Alarm Output 2 x 400mA @ 24V DC (nominal)
Fault Relay Output 1 x relay SELV @ 1A maximum
Fire Relay Output 1 x relay SELV @ 1A maximum
Zone Capacity 32 devices per zone
Remote Sounder Activation Via N/O contact (class change)
Sounder Activation Delay 0-9 minutes in 1 minute increments
Zone End Of Line IN4002 Diode (cathode stripe to +)
Sounder End Of Line 10K resistor
Charger Voltage 28.4V @ 20°C (with battery disconnected)
Zone Short Circuit Protection 100mACharger Short Circuit Protection Battery voltage less than 20V
Enclosure Size 355 (l) x 275 (h) x 100 (d) mm
Weight 3.25kg (excluding batteries)
Features
LPCB Approved to EN54 parts 2 & 4
One man test facility
Disablement facility for zones & sounders
Space for up to 7Ahr batteries
Sounder delay option (0 – 9 min) Panel can be ush mounted
73mm 100mm
Wall MountFlush Mount
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
9/44
Premier Elite Conventional Fire Alarm Panel(PE1, PE2, PE4, PE6, PE8)
The Premier Elite 1-8 zone re alarm
panels are ideal for small to medium sized
installations. They meet all the requirements
of EN54 parts 2 & 4, and come in an
attractively styled enclosure.
The zonal output card gives a drive voltage to operate
zonal alarm relays, or a hardwired repeater panel.
Model PE1 PE2 PE4 PE6 PE8
Part No. 37-040 37-041 37-042 37-043 37-044
Detection Zones 1 2 4 6 8
Mains Voltage 230V AC +10%/-15% @ 50/60Hz
System Voltage 24V DC (nominal) 29V DC (nominal)
Zone Voltage 22V DC (nominal)
Sounder Alarm Output 2 x 400mA @ 24V DC (nominal)
Fault Relay Output N/A 1 x relay SELV @ 1A maximum
Fire Relay Output 1 x relay SELV @ 1A maximum
Zone Capacity 20 Devices 32 Devices
Remote Sounder Activation N/A Via N/O Contacts
Sounder Activation Delay N/A 0-9 minutes in 1 minute increments
Zone End Of Line 10K resistor IN4002 Diode (cathode stripe to +)
Sounder End Of Line 10K resistor 10K resistor
Charger Voltage 27.6V DC (No Batt Connected) 28.4V @ 25°C (No Battery Connected)
Zone Short Circuit Protection N/A 100mA
Charger Short Circuit Protection N/A Batteries less than 21V
Operating Temperature 0°C to 50°C
Enclosure Size 355 x 275 x 100mm
Weight 2.5kg (excluding batteries) 3.25kg (excluding batteries)
Features
Fault relay (4, 6 & 8 zone only)
Alarm relay
Current limited charger to prevent at batteriesdrawing too much current (4, 6 & 8 zone only)
Built in diode base compatibility (4, 6 & 8 zoneonly)
Sounder delay facility (4, 6 & 8 zone only)
Connection to optional add on zonal output card
(4, 6 & 8 zone only)
Zone disablement facility (4, 6 & 8 zone only)
One man test facility (4, 6 & 8 zone only)
73mm 100mm
Wall MountFlush Mount
9
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
10/44
Premier Conventional Repeater Panel(PRE-REP)
Model PRE-REP
Part No. 37-045
Supply Voltage 20–35V DCSupply Voltage 29V DC (nominal)
Connections
A+
0V
GA
CF-
TN-
Z1- to Z8-
Supply +VE
Supply –VE
General Alarm
Common Fault
Tone (Buzzer Active)
Zonal Alarm
Operating Temperature -0°C to 50°C
Enclosure Size 355 x 275 x 100mm
Weight 1kg
The Premier Repeater panel is a hard-wired
repeater panel for use with the Premier SX (all
sizes), and the Premier Elite (4-8 zone) panels.
It is display only (no controls) and indicates power,
general fault, general re & the zone in alarm. It also
has an internal buzzer to indicate that it requires
attention.
It comes supplied with an interface card to connect to
the Premier SX and Premier Elite (4-8 zone) panels.
Features
Zonal indication for re
Common fault indication
Surface or semi ush xing
73mm 100mm
Wall MountFlush Mount
0
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
11/44
Premier M Plus 8-24 Zone Conventional FireAlarm Panel (PMP8, PMP16, PMP24)
The Premier M Plus control panels are designed
to full the requirements of EN54 parts 2 & 4
as well as being easy to install, operate and
maintain.
Being of modular construction, the basic M Plus panel
has 8 zone capacity, expandable to 16, 20 and 24 zones.
The Premier M Plus is suitable for surface mounting or
semi-ush tting (with just the door protruding).
Model PMP8 PMP16 PMP24
Part No. 37-020 37-022 37-024
Detection Zones 8 16 24
Mains Voltage 230V AC +10% / -15% @ 50/60 Hz
System Voltage 24V DC (nominal)
Zone Voltage 21V DC
Sounder Alarm Output 4 x 150mA @ 24V DC
Fault Relay Output 1 x relay SELV @ 1A maximum
Fire Relay Output 1 x relay SELV @ 1A maximum
Zone Capacity 32 Devices
Remote Sounder Activation N/A
Sounder Activation Delay 0 – 9 minutes in 1 minute increments
Zone End Of Line IN4002 Diode
Sounder End Of Line 10KΩ Resistor
Charger Voltage 28.4V DC (batteries disconnected)
Zone Short Circuit Protection 100mA
Charger Short Circuit Protection Batteries less than 20V
Charger Size 3.0 Amp
Operating Temperature 0°C - 50°C
Enclosure Size 485 x 477.5 x 125mm
Features
4 Common sounder circuits (150mA each)
Optional add-on zonal sounder circuits (50mAMax.)
Serial repeater output
Auxiliary supply (29 Volts, 250mA)
Zone & sounder disablement facility
Sounder delay facility
Zonal to common timer (when tted with zonalsounder boards)
One man test mode
11
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
12/44
Premier M Plus Repeater Panel(PMP-REP, PMP-REP/M)
Model PMP-REP PMP-REP/M
Part No. 37-026 37-027
Functions Display & control Control only
Supply Voltage 20-30V DC
Max. Quantity Per System 1 5
Connections
Serial Repeater A
Serial Repeater B
+24V DC
0V
Operating Temperature 0°C to 50°C
Enclosure Size 375 x 335 x 125mm
Weight TBC
The Premier M Plus repeater is available in 2
versions – standard & multiple.
The standard repeater offers display & control
functions, however it is limited to one per system.
The second version allows multiple repeaters on the
same system however they do not have any control
functions (i.e. they cannot be used to silence or reset
the system).
A single repeater can be powered from the panels’
auxiliary 24V supply. If more than one repeater is to be
used, a separate 24V is required.
2
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
13/44
Premier 48 M Plus 24-48 Zone ConventionalFire Alarm Panel (PMP48/24, PMP48/32, PMP48/40, PMP48/48)
The Premier 48 M Plus control panels are designed to
full the requirements of EN54 parts 2 & 4 as well as
being easy to install, operate & maintain.
Being of modular design, the basic panel has 24 zones
built in and it can be expanded to 32, 40 & 48 zones.
The construction of the panel is epoxy painted steel
enclosure, with top & rear cable entries.
Model PMP48/24 PMP48/32 PMP48/40 PMP48/48
Part No. 37-030 37-032 37-034 37-036
Detection Zones 24 32 40 48
Supply Voltage 230V AC +10%/-15% @ 50/60 Hz
System Voltage 29V DC (nominal)
Zone Voltage 21V DC
Sounder Alarm Output 4 X 400mA @ 24V DC
Fault Relay Output 1 relay SELV @ 1A (normally energised)
Fire Relay Output 1 relay SELV @ 1A maximum
Other Connections Class Change Input (N/O Contact) / F.A.R.E. Output / Serial Repeater Output (4 Wire)
Zone Capacity Up to 32 devices
Remote Sounder Activation N/A
Sounder Activation Delay 0 to 9 minutes
Zone End Of Line 100μF capacitor
Sounder End Of Line 10K resistor
Charger Voltage 28.4V DC (Batteries disconnected)
Zone Short Circuit Protection 100mA
Charger Short Circuit Protection Batteries less than 20V
Charger Size 3 Amp
IP Rating IP43
Operating Temperature 0°C to 50°C
Enclosure Size 675 x 480 x 135mm
Weight 13kg
Features
4 common sounder circuits (400mA each) Optional add-on zonal sounder circuits (50mAMax)
Serial repeater output
Auxiliary supply (29 Volts, 250mA)
Zone & sounder disablement facility
Sounder delay facility
Zonal to common timer (when tted with zonalsounder boards)
One man test mode
13
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
14/44
Premier 48 M Plus Repeater Panel(PMP48-REP, PMP48-REP/M)
Model PMP48-REP PMP48-REP/M
Part No. 37-037 37-038
Functions Display & control Control only
Supply Voltage 20–30V DC
Maximum Quantity Per System 1 5
Connections
Serial Repeater A
Serial Repeater A
+24V DC
0V
Operating Temperature 0°C to 50°C
Enclosure Size 480 x 330 x 60mm
Weight 4.8kg
The Premier 48 M Plus repeater is available in
2 versions – standard & multiple.
The standard repeater offers display & control
functions, however is limited to one per system.
The second version allows multiple repeaters on the
same system however they do not have any control
functions (i.e. they cannot be used to silence or reset
the system).
A single repeater can be powered from the panels’
auxiliary 24V supply. If more than one repeater is to be
used, a separate 24V is required.
4
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
15/44
Premier MX Conventional Fire Alarm Panel(MX-16 & MX-32)
The Premier MX ranges of panels are available
in either 16 or 32 zone versions and have been
approved by LPCB to EN54 parts 2 & 4.
The panels offer an extensive range of conguration
options whilst remaining easy to install and congure.
Features
LPCB Approved to EN54 parts 2 & 4
Zonal one-man test facility
Latching or non-latching zones
Delayed or non delayed zone operation
Standard or intrinsically safe zone mode
Short circuit to re mode for compatibility withold detectors
Zonal or common alarm operation (requiresoutput expansion PCBs)
Latching or non-latching fault modes
Fault routing, re routing & re protectionrelays can be programmed as 24V output(monitored) or volt free
Fault routing, re routing & re protectionrelays can have delayed operation in anyconguration
The panel is available as ush mount on request
Repeater panel option (up to 5 maximum perpanel)
Model MX-16 MX-32
Part No. 37-140 37-142
Detection Zones 16 32
Supply Voltage 230V AC +/- 10%
System Voltage 24V DC (Nominal)
Zone Voltage 24V DC (Nominal) Relay, SELV @ 1A
Zone End of Line 22uF, 35V Axial Capacitor
Sounder Output 4 X 1.0A @ 24V DC
Sounder EOL 3K9 Resistor
Aux DC Output 24V DC (Nominal) 1A
Repeater option Yes
Panel Inputs
Remote
Evacuation
Remote Silence
Alarms
Remote Reset
Class Change
Panel Outputs
Fault Routing
Relay, SELV @ 1A
Fire Routing
Relay, SELV @ 1A
Fire Protection Relay,
SELV @ 1A
Disablement Active(Open Collector
Output)
Evacuation Active
(Open Collector
Output)
Buzzer Active (Open
Collector Output)
RS 485 Repeater
Connection
Operating
Temperature
-5°C to 40°C
Size 325 x 370 x 126mm 400 x 441 x 131mm
Weight 7.05kg 9.35kg
15
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
16/44
Fyreye Extra ConventionalOptical Smoke Detector (FEOE2000)
The Fyreye Extra optical smoke detector uses
a pulsing IR LED & photodiode to detect IR
scatter caused by smoke entering the chamber.
The detector is particularly suitable for detecting
optically dense smoke, involving materials such as soft
furnishings, PVC, plastic, foam and all similar materials
which produce small visible particles (0.5 to 10μm).
The detector will work with most modern re alarm
control panels and comes supplied with a locking grub
screw to prevent unauthorised head removal.
The Fyreye Extra range of detectors has an extra LED to
improve detector identication in an alarm condition.
Features
Designed to meet EN54 requirements
Attractive design
Dual LEDs for 360° visibility
Lockable base to stop unauthorised removal
Compatible with all Fyreye bases
Model FEOE2000
Part No. 80-022
Detector Class Optical Smoke
Design Standard EN54 part 7
Approval DIFTOperating Voltage 9-33V DC
Quiescent Current 65μA
Alarm Current @ 24V DC 53mA MAX
Operating Temperature -10°C to +50°C
Minimum Continuous Temperature 0°C
Maximum Humidity 95% RH non-condensing
Alarm Condition 2.4% obscuration per metre
Coverage 100m2
IP Rating IP43
Start-up Time 10 SecondsSize (with Base) 100 x 37mm (101 x 53mm)
Weight (with Base) 95g (153g)
37mm100mm
6
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
17/44
Fyreye Extra Conventional Rate of Rise andFixed Heat Detectors (FEHE2000 & FEFHE2000)
The Fyreye Rate of Rise heat detector
(FEHE2000) uses a thermistor arrangement
to sense a quick rise in temperature and also
a nal threshold temperature of 57°C. The
Fyreye xed heat detector (FEFHE2000) has a
single thermistor arrangement that gives an
alarm at a temperature of 90°C.
The detectors will work with most modern re alarm
control panels and comes supplied with a locking grub
screw to prevent unauthorised head removal.
The Fyreye Extra range of detectors has an extra LED to
improve detector identication in an alarm condition.
Model FEHE2000 FEFHE2000
Part No. 80-038 80-039
Detector Class Rate of Rise & Fixed Heat Detector Fixed Heat Only
Design Standard EN54 part 5
Approval DIFTOperating Voltage 9-33V DC
Quiescent Current 40μA
Alarm Current @ 24V DC 34mA
Operating Temperature -10°C to +50°C
Minimum Continuous Temperature 0°C
Maximum Humidity 95% RH non-condensing
Alarm Condition Rate of rise or xed heat trigger @ 57°C Fixed heat trigger @90°C
Coverage 50m²
IP Rating IP43
Start-up Time 10 SecondsSize (with Base) 100 x 48 mm (101 x 64 mm)
Weight (with Base) 75g (133g)
Features
Designed to meet EN54 requirement
Lockable to base to stop unauthorised removal
Remote LED output
Dual LEDs for 360° visibility
Compatible with all Fyreye bases
48mm100mm
17
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
18/44
Fyreye Extra ConventionalOpto-Heat Detector (FEOH2000)
The Fyreye Extra opto-heat detector
incorporates both an optical chamber and
heat sensing element with advanced detection
technology & discrimination algorithms. This
multisensor is the perfect replacement for
ionisation detectors.
The detector will work with most modern re alarm
control panels and comes supplied with a locking grub
screw to prevent unauthorised head removal.
The Fyreye Extra range of detectors has an extra LED to
improve detector identication in an alarm condition.
Features
Advanced electronic technology used tominimise false alarms
Designed to meet EN54 requirement
Built-in 10 seconds alarm verication
Lockable to base to stop unauthorised removal
Remote LED output
Dual LEDs for 360° visibility
Compatible with all Fyreye bases
Model FEOH2000
Part No. 80-025
Detector Class Optical / Heat
Design Standard EN54
Approval DIFTOperating Voltage 17-20V DC
Quiescent Current 100μA
Alarm Current @ 24V DC 70mA MAX
Operating Temperature -20°C to +60°C
Minimum Continuous Temperature 0°C
Maximum Humidity 95% RH non-condensing
Alarm Condition 3% obscuration per metre
Coverage 100m²
IP Rating IP43
Start-up Time 10 SecondsSize (with Base) 100 x 50mm (100 x 66mm)
Weight (with Base) 95g (153g)
50mm100mm
8
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
19/44
Fyreye ConventionalUltra-Violet Flame Detector (FEUV2000)
Model FEUV2000Part No. 80-045
Detector Class Ultra Violet Flame Detector
Operating Voltage 12-28V DC
Quiescent Current 320μA
Alarm Current @ 24V DC 45-50mA
Operating Temperature 0°C to 45°C
Minimum Continuous Temperature 0°C
Maximum Humidity 95% RH non-condensing
Alarm Condition 10 seconds for 30mm ame @ 4 metres
Detection Angle 120°UV Sensitivity 185-260nm
Size (with Base) 98 x 36mm (98 x 52mm)
Weight (with Base) 85g (143g)
The Fyreye ultra-violet am detector is
particularly suited to applications where
ames can be expected to develop initially
rather than smoke. This is typically due to the
nature of the materials being protected for
instance camera lm, computer, audio & video
tapes or disks.
The detector is for indoor use only and should not
be exposed to spurious sources of UV, such as sparks,
uncovered halogen lights, lightening, etc. as these maytrigger a false alarm.
Due to the operational nature of ame detectors it is
generally recommended to t just one detector per
zone.
Features
Low prole shape
The detector is solar blind and incorporates an
electronic lter to eliminate unwanted alarmsfrom naturally occurring phenomena
Fast response time
High immunity to electrical noise & RFinterference
UV EMISSIONPOINT
VERTICAL VIEWING
(top fig.)
HORIZONTAL
VIEWING
(bottom fig.)
90°90°
60°60°
30°30°
0°
ANODE
CATHODE
90°90°
60°60°
30°30°
0°
ANODE
CATHODE
Horizontal & Vertical Detector Field Of View
19
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
20/44
Fyreye Conventional Detector Bases(FE-CB, FE-DB, FE-RB)
Model FE-CB FE-CB/S FE-CB/D FE-DB FE-DB/S FE-DB/D FE-RB
Part No. 80-050 80-050S 80-050D 80-052 80-052S 80-052D 80-054
Type Common base Diode base Relay base
Supply Voltage 9-33V DC 24V DC
Quiescent Current @ 24V 0μA
Alarm Current @ 24V 0mA 15mA
Relay Max Switching Power N/A 30W, 50VA
Relay Max Switching Power N/A 30W, 50VA
Relay Max Switching Current N/A 1A resistive
Relay Max Switching Voltage N/A 50V AC
Relay Minimum Capability N/A 10μA, 10mV
Relay Dropout Voltage N/A
8/9/2019 Conventional Catalogue
21/44
Zeta Remote LED Indicator(ZT-RL)
Model ZT-RL
Part No. 48-023
Input Voltage 5 – 30vdc
Quiescent Current 0mA
Alarm Current 12mAOperating Temperature 0°C - 50°C
Max Humidity 95% Relative Humidity Non-condensing
IP Rating IP41
Size 85 x 85 x 70mm
Weight 113g
Remote LEDs indicators are used in
installations where a detector going to alarm is
likely to occur out of sight (for instance behind
a locked door or in a ceiling void). In these
instances the indicator will then show the
location of the alarm.
Features
Twin LED’s
Surface or ush mounting
21
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
22/44
Fyreye 50 & 100m Reective BeamSmoke Detector (ZT-50RZ, ZT-100RZ, ZT-50RV & ZT-100RV)
The Fyreye reective beam detectors comprise
of a single unit incorporating an infrared
transmitter & receiver. The signal is reected
by a prism and analysed for smoke presence.
Should a predetermined level be reached then
the detector will signal an alarm.
The system is designed to be mounted so that the beam
will project between 0.3 and 0.6 metres below the
ceiling and parallel to it. Lateral detection may be up to
7.5 metres either side of the beam.
Features
50 or 100 metre reective beam smoke detector
VdS approved
Complies fully to;
BS 5839 part 5
EN54 part 12
Single compact housing
Horizontal or vertical mounting
12-24V DC operation
Low current consumption
Latching or non latching alarm
Reector targeting mode to ease set-up
Microprocessor controlled
Automatic contamination compensation
Selectable sensitivity
Robust construction
126mm 120mm
1 4 0 m m
2 1 0 m m
70mm
100mm
1 0 0 m
m
9.5mm
2
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
23/44
Model ZT-50RZ ZT-100RZ ZT-50RV ZT-100RV
Part No. 47-050 47-051 47-050A 47-051A
Range 5-50m 50-100m 5-50m 50-100m
Number of Wires 2 4
Supply Voltage 10.2V to 30V DC
Quiescent Current
8/9/2019 Conventional Catalogue
24/44
Fyreye 50 & 100m Auto-aligning Beam SmokeDetector Systems 50 & 100m (ZT-5000R & ZT-5000R/100)
Features Worldwide approvals including EN54:12 andUL268
Up to 4 detectors per system controller
Each detector congurable from 8m to 100m
Integral LASER
Auto-align fast automatic beam alignment
Auto-optimise building movement andcontamination compensation
Low level system controller 20mm cable gland knockouts on systemcontroller
2-wire interface from system controller todetector
Additional System Components
ZT-5000R/DH - 47-072 - Fyreye Auto-aligning SingleBeam Detector Head 50m
ZT-5000R/100/DH - 47-073 - Fyreye Auto-aligningSingle Beam Detector Head 100m
ZT-5000R/LRK - 47-074 - Fyreye Auto-aligning BeamDetector Long Range Kit
The system consists of 2 parts; the beam detector itself
and a low level control unit.
The system can be fully customised, according to local
conditions and installation guidelines; alarm thresholds
(sensitivity) and time to alarm/fault can be set from the
low level system controller.
Each detector head is independently congurable from
8m through to 100m and has its own individual re
threshold. The system controller retains one set of re
and fault relays that is common to all detectors that are
installed.
The system is supplied as either a 50 or 100 metreversion with a single detector head. Additional heads
and a long range kit (additional prisms to allow the
detector head to reach 100m) are available separately.
Based on the proven technology of the
standard Fyreye reective beam detectors, the
Fyreye auto-aligning beam detector has been
designed to help improve ease of installation.
The system is ideally suited for the protection of
large areas where the use of traditional detection
technologies would prove to be too difcult and/or
costly to install.
The system combines an infrared transmitter and
receiver in the same discrete unit and operates by
projecting a well-dened beam to a reective prism,
which returns the beam to the receiver for analysis.
Smoke in the beam path causes a drop in power, which,
if below a pre-determined level, results in an alarm
signal.
4
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
25/44
Model ZT-5000R ZT-5000R/100
Part No. 47-070 47-071
Range 50m 100m
Number of Wires 4
Supply Voltage 14-28V DC
Operating Current8-12mA (low current mode with 1 detector)48-52mA (high current mode with 1-4 detectors)
Operating Temperature -20°C to 55°C
Storage Temperature -40°C to 85°C
Max Humidity 85% RH non-condensing
Max Wind Speed Not affected
Alarm Current 35mA (typical)
Fire Output Volt free relay contact
Fault Output Volt free relay contact
Beam Misalignment Tolerance @ 35% Detector ± 0.8°, Prism ± 5.0°
Alarm Thresholds 2.50dB (25%), 3.74dB (35%) & 6.02dB (50%)
Optical Wavelengths 850nm
Construction Flame Retardant ABS (Grey / Black)
IP Rating IP54
Detector Size 135 x 135 x 135mm
Detector Weight 0.5kg
Controller Size 202 x 230 x 81mm
Controller Weight 0.9kg
135mm 135mm
202mm 81mm
2 3 0 mm
1 3 5 mm
25
8/9/2019 Conventional Catalogue
26/44
Zeta UV/IR Optical Flame Detectors(VS-200P & VS-200EX)
Features
UV/IR spectrum for medium distance detectionand high false alarm immunity
Compact & lighter design
User selectable sensitivity & functions
Multiple output options (relays for alarm & fault,0-20mA (stepped) and RS-485/RS-232 spectrummonitoring)
ATEX approved by DNV for explosion-proof (VS-
200EX UV/IR only)
CE certied
TypicalApplications
Non-hazardous (VS-200P)
Parking buildings
Warehouse
Waste disposal facilities
Culture centres
Hazardous (VS-200EX)
Offshore oil & gasinstallations
Onshore oil & gasinstallations andpipelines
Petrochemical plants
Chemical plants
Shipbuilding facility
Automotive industry
Storage tank farms
Power generationfacility
Petrochemical plants
Painting industry
Warehouse
Waste disposal facility
Explosive & munitions
The VS-200P & VS-200EX UV/IR ame detectors
detect fuel & gas res at long distances with
the highest immunity to false alarms. The
detectors can detect a 0.1m² gasoline pan reat 30m in less than 5 seconds.
VS-200P VS-200EX
6
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
27/44
Model VS-200P VS-200EX
Part No. 47-150 47-151
Spectrum Response UV /IR (Dual Bands)
Spectrum Response
(at highest sensitivity settingfor 0.1m² pan re)
Fueln-Heptane
Gasoline
Diesel
LPG*
Distance30m
30m
20m
20m
FuelEthanol
IPA
Methanol
Distance20m
25m
20m
*0.5m high / 0.2m width plume re
Response Time Typically 5 seconds
Adjustable Time Delay Up to 20 seconds
Sensitivity Range 4 sensitivity ranges for 0.1m² n-Heptane pan re from 15m to 65m
Field of View Horizontal 90°, Vertical 90°
Built-in-Test Manual (optionally Automatic)
Temperature Range Operating/Storage: -40°C to 75°C
Humidity Up to 95% non-condensing
Operating Voltage 24VDC norminal (17-31VDC)
Power Consumption Standby: max. 35mA, Alarm: max. 75mA
Cable Entry 1 x M20 (ISO)
Wiring AWG 16-26 (Str 1.5mm² to 0.13mm²)
Electromagnetic Compatibility EMI/RFI protected to EN61000 series
Electrical Interface The detector includes twelve(12) terminals with four(4) wiring options
Relays Alarm, Fault. SPST volt-free contacts rated 5A at 30VDC or 250VAC
0-20mA (stepped)
Non-isolated “Source” conguration
Fault:Normal:
Alarm:
0 +1mA4mA±10%
20mA±10%
Bit Fault:
Warning:Resistance
Loop:
2mA±10%16mA±10%
Max. 800Ω
Materials Polycarbonate Enclosure
Heavy duty copper free aluminium (less than 1%) with bright grey
anodizing nish
Enclosure options - Stainless Steel 316L with electro polish nish
Mounting (Tilt Mount) Stainless Steel
Heavy duty copper free aluminium (less than 1%) with grey epoxy
enamel nish
Options - Stainless Steel 316L with electro polish nish
DimensionsDetector: 80 x 82 X 86
mmDetector: 83(d) x 126(l) mm
Weight
Detector : 0.3kg (1.0kg
with cable gland /
1m-length cable / TiltMount)
Detector (aluminium): 1.1 kg (1.4 kg with Ex cable gland /
1m-length
Detector (St. SUS316L): 2.0 kg
Tilt mount (aluminium/ St.): 0.3kg / 0.7kg
Water and Dust IP66 per EN60529 IP66 and IP67 per EN60529
EMI/RFI CE MarkingATEX Ex II 2 G
Exd IIC T6, -40°C to +75°C (DNV 09 ATEX 0000)
PerformanceEN54-10 (designed tomeet)
KFI (Korea)
EN54-10 (designed to meet)
27
8/9/2019 Conventional Catalogue
28/44
Zeta Conventional Manual Call Points(ZT-CP2, ZT-CP2/W, ZT-CP1 & ZT-CP1/W)
The Zeta conventional manual call point has
a modern design and has been approved by
BSI to EN54 part 11. It is a resettable call
point that signals an alarm with a yellow ag
entering the window area and a red alarm LED.
There are two versions available; the ZT-CP2 call points
comes complete with a protective Perspex cover as
well as a “snaplatch” catch that needs to be broken off
before the call point cover can be lifted (this acts as a
deterrent to malicious activations and forms a Type B
call point). Alternatively the ZT-CP1 is supplied withoutthe Perspex cover & “snaplatch” and is single action or
Type A call point.
The recommended colour for these call points is red
however white is also available to meet architectural
requirements.
Model ZT-CP2 ZT-CP2/W ZT-CP1 ZT-CP1/W
Part No. 43-300 43-314 43-301 43-317
Type Type B Type A
Element Type Resettable
Alarm ActivationBreak “snaplatch”, lift Perspex cover, press
elementPress element
Colour Red White Red White
Input Voltage 9-33V DC
Quiescent Current 0mA
Alarm Current Typical 35mA (maximum 51mA)
Alarm Load 470 Ω resistor
Operating Temperature -20°C to 50°C
Max Humidity 95% RH non-condensing
IP Rating IP43
Size 111 x 100 x 67mm 105 x 100 x 58mm
Weight 198g 175g
Features
BSI approved to EN54 part 11
Attractive design
8
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
29/44
Zeta Conventional Weatherproof Call Point(ZT-CP2/WP)
Model ZT-CP2/WP
Part No. 43-350
Type Type B
Element Type Resettable
Alarm Activation Break “snaplatch”, lift Perspex cover, press element
Colour Red
Input Voltage 9-33V DC
Quiescent Current 0mA
Alarm Current Typical 35mA (maximum 51mA)
Alarm Load 470 Ω resistor
Operating Temperature -20°C to 50°C
Max Humidity 95% RH non-condensing
IP Rating IP65Size 87 x 87 x 70mm
Weight 198g
The Zeta conventional weatherproof manual
call point is an IP65 rated call point which
complies with EN54 part 11. It is resettable
and signals an alarm with a yellow ag
entering the window area and a red alarm LED.
The call point comes complete with a protective Perspex
cover as well as a “snaplatch” catch that needs to be
broken off before the call point cover can be lifted (this
acts as a deterrent to malicious activations and forms a
Type B call point).
Features
Complies with EN54 part 11
Attractive design
Resettable element
Protective cover
29
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
30/44
Zeta Conventional Explosion ProofManual Call Point (ZT-BGU/WP/R & ZT-BGU/WP)
The Zeta conventional explosion proof manual
call point is manufactured from aluminium
with a built-in push button activator. The call
point is nished with red anti-corrosive epoxy
powder coating with 2 x 20mm cable entries.
This unit is equipped with a stainless steel
hammer and chain.
Two models are available; the ZT-BGU/WP/R with 470Ω
built-in resistor for connection to a standard re alarm
system or the ZTBGU/WP for mains connection.
Model ZT-BGU/WP/R ZT-BGU/WP
Part No. 43-300/WP 43-305/WP
Contact Rating 10 Amp
Voltage Rating 500V AV
Build-in Resistor 470Ω N/A
IP Rating IP65
Earthling 2No M6 eternal & 1No M5 internal
Size TBC
Weight 1.5kg
2 Nos.0.75″ET
B R E A
K G L
A S
S
I N
C ASE O F
F I RE185mm
105mm
4 Holes - ø7
Hammer
Chain
0
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
31/44
Miditone Conventional Electronic Sounder(ZMDD/8R & ZMDD/8W)
The Miditone sounder is a small, high output
conventional sounder which designed to meet
the requirements of EN54 part 3 and is CE
marked.
The sounder is a compact unit that ts a standard
European back box and can be either surface or ush
mounted. It has a choice of 8 tone patterns, selectable
by an internal dip switch and a sound output of 95dB @
1m with volume control.
It is available in red or white to meet architectural
requirements.
Features
Complies to EN54 part 3
95dB @ 1m sound output
8 Tone patterns
Flush or surface xing
Model ZMDD/8R ZMDD/8W
Part No. 42-040 42-040A
Sound Output See current consumption table
Colour Red White
Operating Voltage 9-30V DC
Quiescent Current 0mA
Alarm Current @ 24V See current consumption table
Operating Temperature -10°C to 50°C
Minimum Continuous Temperature 0°C
Maximum Humidity 95% RH Non Condensing
IP Rating IP43
Size (with Back Box) 85 x 85 x 35mm (85 x 85 x 67mm)
Weight (with Back Box) 100g (150g)
DIL Switch Settings (SW4 N/A)
1 2 3 Tone Description dB Level Current (mA)
Off Off Off Sweep Negative 1200- 500 Hz In 1 Second 97 (+/- 2dB) 21
On Off Off Alternating 554 and 440Hz 0.5s Each 95 (+/- 2dB) 17
Off On Off Continuous 660Hz 96 (+/- 2dB) 22
On On Off Alternating 554Hz @ 0.1s/440Hz @ 0.4s 94 (+/- 2dB) 17
Off Off On Intermittent 970Hz @ 0.5s On/Off 93 (+/- 2dB) 8-24
On Off On Continuous 970Hz 95 (+/- 2dB) 25.5Off On On Sweep Positive 800-970Hz 99 (+/- 2dB) 25
On On On Alternating 800 and 970Hz @ 0.25s Each 100 (+/- 2dB) 25
31
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
32/44
Miditone Conventional Combined ElectronicSounder & Flasher (ZMDF/8R, ZMDF/8A, ZMDF/8B, ZMDF/8C & ZMDF/8G)
The Miditone combined sounder & asher is a small, high
output conventional sounder & asher which is designed
to meet the requirements of EN54 part 3 and is CE
marked.
The device is a compact unit that ts a standard
European back box and can be either surface or ush
mounted. It has a choice of 8 tone patterns, selectable
by an internal dip switch and a sound output of 95dB
@ 1m with volume control. This is an ideal solution to
upgrade an existing sounder to a combined sounder &
asher.
It is available with either a red, amber, blue, clear or
green lens to meet architectural requirements.
Model ZMDF/8R ZMDF/8A ZMDF/8B ZMDF/8C ZMDF/8G
Part No. 42-024 42-024A 42-024B 42-02C 42-024G
Sound Output See current consumption table
Lens Colour Red Amber Blue Clear Green
Operating Voltage 17-30V DC
Quiescent Current 0mA
Alarm Current @ 24V See current consumption table
Operating Temperature -10°C to 50°C
Minimum Continuous Temperature 0°C
Maximum Humidity 95% RH non condensing
IP Rating IP43
Size (with Back Box) 85 x 85 x 35mm (85 x 85 x 67mm)
Weight (with Back Box) 112g (162g)
Features
Complies to EN54 part 3
95dB @ 1m sound output
8 tone patterns
Flush or surface xing
DIL Switch Settings (SW4 N/A)
1 2 3 Tone Description dB LEVEL CURRENT (mA)
Off Off Off Sweep Negative 1200- 500 Hz In 1 Second 102 (+/- 2dB) 35
On Off Off Alternating 554 and 440Hz 0.5s Each 100 (+/- 2dB) 27
Off On Off Continuous 660Hz 100 (+/- 2dB) 33
On On Off Alternating 554Hz @ 0.1s/440Hz @ 0.4s 98 (+/- 2dB) 26
Off Off On Intermittent 970Hz @ 0.5s On/Off 93 (+/- 2dB) 13 - 35
On Off On Continuous 970Hz 103 (+/- 2dB) 37
Off On On Sweep Positive 800-970Hz 103 (+/- 2dB) 45
On On On Alternating 800 and 970Hz @ 0.25s Each 103 (+/- 2dB) 42
2
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
33/44
Securetone Conventional Electronic Sounder(ZST/8R & ZST/8W)
The Securetone sounder is designed to be
aesthetically pleasing and unobtrusive. It has
an elegant round design and ts to its supplied
mounting plate with a bayonet action to avoid
unsightly screws.
It has 8 selectable tones with a volume adjust screw to
set the required sound level.
This product is designed to meet the requirements of
EN54 part 3 and is CE marked.
Features
8 selectable tones
Volume control
Model ZST/8R ZST/8W
Part No. 42-004 42-004A
Sound Output 100dBA @ 1 metre
Colour Red White
Operating Voltage 10-30V DC
Quiescent Current 0mA
Alarm Current @ 24V 35mA MAX
Operating Temperature -0°C to 50°C
Minimum Continuous Temperature 0°C
Maximum Humidity 95% RH Non Condensing
IP Rating IP43
Size (including Plate) 100 x 100 x 75mm (100 x 100 x 85mm)
Weight (including Plate) 230g (260g)
85mm
1 0 0 mm
33
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
34/44
Secure Light Xenon Flasher(ZTSL6/R & ZTSL6/A)
The Secure Light Xenon Flasher range is
designed to provide a visual warning at alarm
condition.
Both red and amber versions are available with the
lenses constructed of high-Impact and heat resistant
ACRYREX. The case is made of high-impact resistant ABS
plastic.
Features
Available in Red & Amber
Fits onto a standard outlet box
Model ZST/8R ZST/8W
Part No. 42-035 42-038
Colour Red AmberFlash Energy 3 Watt
Flash Frequency 60 times per minute
Operating Voltage 20-30V DC
Quiescent Current 0mA
Alarm Current @ 24V 100mA MAX
Operating Temperature -30°C to 60°C
Minimum Continuous Temperature 0°C
Maximum Humidity 95% RH Non Condensing
IP Rating IP54
Size 97 x 100mmWeight (including Plate) 231g
97mm
1 0 0 mm
4
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
35/44
Maxitone Conventional Sounder andCombined Sounder & Flasher (ZMT/8R, ZMT/8W & ZMTF/8R)
The Maxitone sounder is an ideal alternative
to re bells and for external use. It is housed
in an attractive horn comprises of ame
retardant ABS. Eight selectable tones and
volume control are featured to meet most
requirements.
The Maxitone is also available with transparent
polycarbonate front which will provide both visual and
audible alarm.
Model ZMT/8R ZMT/8W ZMTF/8R
Part No. 42-001 42-001A 42-032
Sound Output See current consumption table
Colour Red White Red
Operating Voltage 17-30V DCQuiescent Current 0mA
Alarm Current @
24VSee current consumption table
Operating
Temperature-20°C to 60°C
MinimumContinuous
Temperature
0°C
Maximum Humidity 95% RH non condensing
IP Rating IP65
Size 124 x 130 x 100mmWeight 357g
120mm
126mm
107mm
DIL SWITCH SETTINGS (SW4 N/A)
1 2 3 Tone Description dB LevelCurrent
(mA)
Off Off Off Sweep Negative 1200-500 Hz In 1 Second
101 (+/-2dB)
27
On Off Off Alternating 554 and
440Hz 0.5s Each
98 (+/-
2dB)20
Off On Off Continuous 660Hz101 (+/-
2dB)27
On On Off Alternating 554Hz @0.1s/440Hz @ 0.4s
98 (+/-2dB)
19
Off Off OnIntermittent 970Hz @
0.5s On/Off
98 (+/-
2dB)20
On Off On Continuous 970Hz103 (+/-
2dB)29.3
Off On OnSweep Positive 800-
970Hz
103 (+/-
2dB)38
On On OnAlternating 800 and
970Hz @ 0.25s Each
102 (+/-
2dB)35
Features
High output
8 selectable tones
Volume control
35
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
36/44
Zeta Conventional Fire Alarm Bells(ZTB6B, ZTB8B/230, ZTB8B & ZTB8B/WP)
The Zeta motorised re alarm bells combine
styling and functional efciency. They
incorporate a low power rotary centrifugal
mechanism, which gives a high sound output
with low current consumption at 24V dc.
The bells are available in 2 sizes; 6″ (152mm) and 8″
(203mm). These sizes suit a wide variety of installations.
There is a 230V ac version of the 6″ bell, and a 24V dc
Weatherproof version of the 8″ bell.
Features
Low current
Universally accepted re evacuation signal
Model ZTB6B ZTB8B/230 ZTB8B ZTB8B/WP
Part No. 41-003 41-004 41-005 41-006
Supply Voltage 18-30V dc 200-250V AC 18-30V dc
Diameter 6″ (152mm) 8″ (203mm)
Quiescent Current 25mA 28mA
Nominal Output @ 1M 95dB(A) 97dB(A)
Dimensions 152 x 152 x 55mm 203 x 203 x 55mm
Weight 860g 960g 1700g 1800g
ZTB6B ZTB8B
152mm 55mm
55mm
1 5 2 m m
203mm
2 0 3 m m
6
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
37/44
Zeta Flame Proof Siren(ZTSR/EXD24 & ZTSR/EXD230)
The Zeta ame proof siren is an explosion
proof siren available in either 24V or 230V
versions.
An intrinsically safe circuit is housed in the main
chamber and it is duly wired up to terminal chamber
through sealed bushes. The horn unit is placed on the
main chamber cover and the output signals are takenthrough sealed coils. Neoprene ‘0’ rings are provided for
the weather proof protection.
Model ZTSR/EXD24 ZTSR EXD230
Part No. 42-100/24 42-105/230
Type Of Protection Flame proof – Exd T6 IP 65
Area Classication Zone 1 & 2
Gas Groups Group I, II A, II B, II C
Apparatus
StandardIS - 2148
CMRI Certicate CMRI / TC / S / H388
Approvals CCE, DGFAS
Materials Cast Aluminium LM 6
Weight 5 Kg (approx.)
Size 170 (w) x 390 (h) x 240 (d) mm
IP Protection IP 65 to IS 13947 / 93
Finish Anti corrosive Epoxy – Powder Coated
Cable Entry 2 x ¾″ ETGasket Neoprene
Hardware Stainless Steel
Terminals4 x 2.5 sq. mm (standard) 6 x 2.5 sq.
mm (for looping)
Voltage 24 V DC 230 V AC – 50 Hz
Output Current 600mA Peak. Galvanically Isolated
Power Rating 18 Watts
Sound Output106 db 900 Hz On & Off alternativelyat 1C/s
EarthingExternal: 2 Nos.
- M6
Internal: 1 No. -
M5
170mm 240mm
3 9 0 mm
37
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
38/44
Zeta Flame Proof Gong Bell(ZTB8B/EXD/24)
The Zeta ame proof gong bell is an explosion
proof gong bell with a terminal chamber.
A highly reliable electric circuit is housed inside to
control the frequency of the gong operating spindle.
The operating spindle and dish are made out of stainless
steel thereby ensuring a long life.
The electric circuits are connected to terminals in
the terminal chamber through nipple. The covers are
provided with neoprene gaskets for weatherproof
protection.
Model ZTB8B/EXD
Part No. 41-075
Type Of Protection Flame proof – Exd T6 IP 65
Area Classication Zone 1 & 2
Apparatus Standard IS - 2148
Material Cast Aluminium LM 6
Weight 3 Kg (approx.)
Size 225(w) x 285(h) x 160(d) mm
IP Protection IP 65 to IS 13947 / 93
FinishAnti Corrosive Epoxy –
Powder coated
Cable Entry 1 X 3/4″ ET
Gasket Neoprene
Hardware Stainless steel
Voltage24V DC or 110V / 230V AC –
50 Hz
Power Rating 12 Watt
Sound Output 112db
Terminals 4 x 4 mm²
EarthingExternal: 2 Nos – M6 Internal:1 No. - M5
225mm 160mm
2 8 5 mm
8
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
39/44
Zeta Magnetic Door Holders(ZT-DR24 & ZT-DR240)
Model ZT-DR24 ZT-DR240
Part No. 50-001 50-002
Rated Voltage 24V DC 230V AC
Rated Current 65mA 6mA
Switch Through Aux Yes No
Needs Back EMF Diode Yes No
Holding Force 400 N
Size (Main Unit) 110 x 85 x 38mm
Dimensions (Keeper Plate) 55 x 55 x 50mm
Weight (Main Unit) 404g
Weight (Keeper Plate) 153g
The Zeta magnetic door holders are designed
to retain a re door open against the force of
its own closing device. In the event of a re,
the door holder magnet can be turned off bythe re alarm, allowing the door to shut.
The manual release button is changeable from the base
side to left or right. Cable entry is possible from rear
side by means of enclosed exits from the base side, left
or right.
An optional bracket is also available for oor or wall
mounting (ZT-BR).
Features
Tested according to EN1155
ZT-BR
39
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
40/44
Zeta Duct Unit(ZT-DU, ZT-DU/12 & ZT-DU/230)
The Zeta duct unit allows air in a ventilation
duct to be monitored for smoke via a smoke
detector mounted externally in a sealed
chamber. The unit comes supplied with 2
sampling probes (one in & one out) which are
mounted through the duct in the centre of the
air ow.
There are 3 versions of the unitavailable which are as follows;
ZT-DU – enclosure supplied with a Fyreye common base(FE-CB) allowing either a conventional or addressable
Fyreye detector to be connected and wired as part a
system.
ZT-DU/12 – enclosure c/w Fyeye base and relay boardwith form C relay outputs for alarm and for fault which
requires 12V power supply.
ZT-DU/230 - enclosure c/w Fyeye base and relay boardwith form C relay outputs for alarm and for fault which
requires 230V power supply.
Please note for reliable smoke detection the air speed in
the duct must be at least 2.5m/s.
Features
Fire and Fault relays
Option for latching or non-latching
Manual reset (latching option)
Model ZT-DU ZT-DU/12 ZT-DU/230
Part No. 48-011A 48-011B 48-011C
Supply Voltage N/A 12V 230V
Stand by current N/A 46mA (From 12v supply)
Alarm current N/A 86mA (From 12v supply)
Fault current N/A 26mA (From 12v supply)
Indications N/A Power, fault & alarm
Outputs N/A 1 x fault relay & 1 x alarm relay
Size 190 x 227 x 70mm
Weight 728g 989g
Direction of Airflow
Duct Wall
Test Point
0
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
41/44
Premier Power Pack EN 54-4 Power Supplywith LCD Screen (PP-2/12, PP-5/17)
The Premier Power Pack Power supply uses an
innovative design that allows the engineer to
view system status through the on board LCD
screen. The screen can display several power
supply parameters, including output voltage,
and output current.
The power supply itself uses a 3 state charger which
uses BOOST, FLOAT, and PULSE modes, depending on the
state of the battery.
The PSU will disconnect the batteries under mains failcondition, when the batteries are fully discharged to
prevent damage to the batteries.
The PSU will also monitor the battery for high internal
resistance, and signal a fault if that condition is
detected.Screen Information
System Normal Screen
Z E T A A L A R M S Y S T E M S
P R E M I E R P O W E R - P A C K
R A T I N G 3 0 V D C 2 . 0 A
S Y S T E M N O R M A L
Screen 1 - Main Information
M A I N S : O K B A T T S : O K
V ( A ) = 2 9 . 5 V ( B ) = 2 9 . 5
C U R R E N T 0 . 1 2 A M P S
Screen 2 - Battery Info
B A T T E R Y I M P : 0 . 0 0 3 7
C H A R G E R V O L T : 2 5 . 4 5 V
C H A R G E T Y P E : B O O S T
B A T T E R Y S T A T E : G O O D
Screen 3 - Misc.
E A R T H : 2 . 4 4 7 V G O O D
C H A R G E R C I R C U I T : O K
B A D B A T T E R Y L V L X . X R
Screen 4 - Software Information
S o f t w a r e P S U : 2 V 0 0
S o f t w a r e L C D : 2 V 0 0
Model PP-2/12 PP-5/17
Part No. 46-300 46-305
Input Voltage 170-264V AC 47-63 Hz
Output Voltage 28V DC Nominal 28V DC Nominal
Power Rating 75W 150W
Efciency 79% 86%
Total Power
Output2.0 Amp 5.0 Amp
Power Supply
Outputs2 Fused Outputs 2 Fused Outputs
Maximum Current
Per Output0.625mA 2.0 Amps
Battery Charging
Current750mA 920mA
Fault Relay Rating SELV 1A SELV 1A
IP Rating IP30 IP30
Size 375 x 335 x 128mm 375 x 403 x 128mm
41
Conventional Fire Alarm Systems /
8/9/2019 Conventional Catalogue
42/44
Batteries(Z20201, Z20301, Z20651, Z21251 & Z21751)
As re alarm systems are life safety systems,
they must have a battery backup to ensure full
functionality is maintained in the event of a
mains failure. All parts of the system (including
auxiliary power supplies) must have a battery
backup.
All the batteries stocked are 12V meaning that 2
batteries are required for a 24V systems. The standard
capacities available are 2.2Ah, 3.2Ah, 7Ah, 12Ah and
17Ah.
It is important to choose the correct battery size for the
system load to give the required standby time (usually
24 or 48 hours).
Model Z20201 Z20301 Z20651 Z21251 Z21751
Part No. 46-002 46-100 46-003 46-105 46-004
Type Sealed lead acid
Voltage 12V DC
Capacity 2.2 Ah 3.2 Ah 7.2 Ah 12 Ah 17 Ah
Size 178 x 34 x 65mm 132 x 59 x 65mm 151 x 65 x 98mm 150 x 98 x 103mm 178 x 75 x 168mm
Weight 1.0kg 1.25kg 2.5kg 3.5kg 5.8kg
Battery Calculation
To calculate the required battery backup, we use the equation:-
Battery Size (Standby time in Amp Hours) = 1.25 x [(TALM x IALM) + (TSBY x ISBY)]
Where:
TALM
= Maximum time in hours required for the alarm [½ hour is most common time]
IALM
= Total Alarm Current in amps for all alarm devices connected to the alarm
circuits
TSBY
= Standby time in hours for the system after mains failure [normally 24, 48 or 72
hr]
ISBY
= Quiescent current in amps of control panel in fault condition [because of mains
failure] PLUS all loop devices
2
Conventional Fire Alarm Systems /