Condumax II Transportable 97149 US Datasheet-V1

Embed Size (px)

Citation preview

  • 8/10/2019 Condumax II Transportable 97149 US Datasheet-V1

    1/4

    www.michell.com

    Process Analyzers

    Condumax II TransportableHydrocarbon & Water Dew-Point Analyzer

    Transportable natural gas dew-point analyzer system for operation in the field. Suitable for IECZone 1 or 2 hazardous area, NEC Class I, Division 1 Groups B, C, D.

    Applications

    Spot-check measurements of HC and water dewpoint

    Field verification of installed on-line dew-pointanalyzers

    Flexibility for periodic measurements at any gas

    source

    Producer process stage profiling to optimizeefficiency

    A complete transportable natural gas dew-point analysis system for field spot-check measurements. Periodic online operationwhen located in a temperature maintained analyzer house. Measurements and functionality are instantly accessible throughintegrated alphanumeric display and touch-glass HMI interface including log of dew-point readings for operator review.

    Highlights

    Field transportable self-contained dew-pointanalyzer system

    Simultaneous HC and water dew-pointmeasurements in a single analyzer

    Automatic objective measurements by industry

    proven principles

    Parameter specific sensors ensure continuity ofHC and water dew-point readings

    Self-contained sample handling, conditioning andanalysis package

    0.5C (0.9F) HC dew-point accuracy

    Fundamental cooled mirror principle

  • 8/10/2019 Condumax II Transportable 97149 US Datasheet-V1

    2/4

    www.michell.com

    Process Analyzers

    The Industry Standard HCDP/WDPAnalyzer

    The Condumax II fulfills the demands of natural gasproducers and pipeline transmission companies for reliableon-line monitoring of natural gas hydrocarbon and water dewpoint.

    Condumax II is the industrys analyzer of choice to

    ensure conformance of these key gas quality parameters,from production processing, through trans-continentalpipeline networks into final distribution and utilization bymajor consumers such as power generators. Throughoutthe midstream industry Michell hydrocarbon dew-pointanalyzers are installed as permanent analyzers, providingmeasurements six times every hour 24/7/365.

    Transportable Condumax II for FieldValidation

    The Condumax II Transportable addresses the furtherneeds of natural gas users as the industry evolves. Withan increased proportion of alternative fuel sources suchas biogas, and greater reliance on LNG imports into gasnetworks which traditionally received gas solely from fixedupstream producers, the attention to ensuring accurate

    measurement of dew point has never been more critical.This increased complexity of supply chains has expandedthe number of potential measurement points each requiringconformity to specification. The Condumax II Transportableoffers the flexibility to make investigative spot-checkmeasurements at any location, to even the smallest and mostremote gas source. Furthermore, for the gas producer, theCondumax II Transportable can be used to profile individualprocess stages to ensure optimum efficiency.

    Quality Assurance with a New TransferStandard

    The Condumax II Transportable also enables establishedusers of permanent on-line dew-point analyzers to carry outperiodic comparative measurements in the field to verifymeasurement performance against the certified factorylaboratory calibration of the Condumax II to all users.

    The Condumax II Transportable offers automaticmeasurements of high sensitivity and objectivity whereverthey are needed in a simple to use, self-contained, samplehandling, conditioning and analysis package.

    Sample Conditioning System

    Complete integration of Condumax II Main Unit

    System configuration for connection direct to transmissionpipeline natural gas at typically 70 barg (1015 psig)pressure

    Simultaneous water dew-point measurement at processpressure. Integration of water dew-point sample flow in

    series for analysis at full line pressure

    Process pressure gauge, 100 barg (1450 psig) scale

    Coalescing filter with by-pass needle valve and systemdrain

    Sample gas pressure reduction via electrically-heatedregulator for analysis of HC dew point at intermediatepressure (cricondentherm condition), adjustment range upto 35 barg (507 psig) fitted (analysis pressure indicatedby Condumax II Main Unit)

    Sample flow control with armored rotameter

    *To assure correct measurement performance ofthis system in outdoor field use, the ambient air

    temperature must be at least 5C (9F) above boththe hydrocarbon dew-point temperature of the

    process gas sample at the cricondentherm condition,typically 27 barg (391 psig), and water dew-point at

    full process line pressure.

  • 8/10/2019 Condumax II Transportable 97149 US Datasheet-V1

    3/4

    www.michell.com

    Process Analyzers

    System Connections

    Minimessstainless steel braided, micro-bore hoses

    Sampling system connection: Minimessquick connect

    Set of 3 hoses: Sample inlet, coalescing filter drain /by-pass and sample gas exhaust

    Length: 3m (9.8ft) (each hose)

    Process connection: 316 stainless steel, 1/4 NPT male

    Gas wetted bore: PTFE, 2mm internal diameter

    System Package

    Custom designed and built carry case of heavy dutyconstruction in 316 stainless steel with six vibrationabsorbing feet on base (for transportation) and on oneedge (for upright analyzer system operation)

    Removable case lid secured by four toggle latches. Sixcarry handles for ease of mobility by two persons andtransportation between sites by automobile

    Power consumption:

  • 8/10/2019 Condumax II Transportable 97149 US Datasheet-V1

    4/4

    Process Analyzers

    Michell Instruments adopts a continuous development programme which sometimes necessitates specification changes without notice.Issue no: Condumax II Transportable_97149_V1_US_0913

    2013 Michell Instruments

    Michell Instruments, Inc319 Newburyport Turnpike, Suite 207, Rowley, MA 01969Tel: 978 484 0005, Fax: 978 843 7669, Email: [email protected], Web:www.michell.com/us

    Technical Specifications

    Condumax II Main UnitAnalyzer

    Hydrocarbon Dew-Point Measurement

    Measuring technique Dark Spot fixed sample analysis; Directphoto-detection of hydrocarbon condensate athydrocarbon dew-point temperature

    Sensor cooling Automatic via 3-stage Peltier effect electroniccooler under adaptive control

    Maximum range Up to 55C (131F) measurement depressionfrommain unit operating temperature

    Resolution 0.1C, 0.1F

    Accuracy 0.5C (0.9F) hydrocarbon dew point(single and multiple condensible componentanalysis)

    Sample flow 0.03 to 0.06 m3/hr(0.5 to 1.0 Nl/min / 1.05 to 2.11 scfh)- low flow alarm standard

    Measurement frequency 6 cycles/hour (recommended)12 cycles/hour (maximum)

    Water Dew-Point Measurement

    Measuring technique Michell Ceramic Moisture Sensor

    Unit selectionDew point

    Moisture contentC and F water dew pointlbs/MMscf; mg/m3, ppmV(conversion method IGT#8 or ISO18453)

    Resolution 0.1C, 0.1F dew point0.1 lbs/MMscf, 1 mg/m3 ppmV

    Range Calibrated from -100 to +20C (-148 to +68F)dew point

    Accuracy 1C (1.8F) from -59 to +20C(-74 to +68F) dew point2C (3.6F) from -100 to -60C(-148 to -76F)dew point

    Pressure Measurement(s)Hydrocarbon dew-point analysis pressure

    Units MPa, barg, psig

    Resolution 0.1 MPa and barg, 1 psig

    AccuracyHydrocarbon dew point

    Water dew point0.25 barg0.5 barg

    Hydrocarbon and Water Dew-Point Analyzer

    Sample gas supply Natural gas up to 100 barg (1450 psig),pressure regulated in sampling system

    Enclosure Travel case is stainless steel 316 materialconstruction with removable lid for access andrubber feet for transportation / operation;Instrument is EExd cast enclosure with

    removable viewing port: internally heated forcondensation protection

    Gas connections Sample inlet, filter by-pass outlet, systemdrain.Sample system for: 1/4 NPT female ports,Quick connect Minimesshoses,Process connections: 1/4 NTP male

    Operating environment Indoors/outdoors 0 to +40C (+32 to +104F);Max 95% RH*See cautionary note on page 2

    Power supply 110 or 230 V AC, 50/60 Hz, 300 W

    Weight 60kg (132lbs) (approx)

    Logged data

    Each log

    Visual review

    150 data logs, sufficient for minimum 24 hourperiod (stored in volatile memory);HC dew point and analysis pressure, water dewpoint and process line pressure;HMI display with automatic statistical analysis;maximum, minimum, average values forduration of log period

    Integrated display/keyboard

    Touch screen with vacuum fluorescent display

    Outputs Modbus RTU, RS485 @ 9600 baud rate;Two 4-20 mA linear (non-isolated) outputs,user configurable for any combination of dewpoint or pressure parameters;Additional connection junction box requiredexternally

    Alarms Process and analyzer status via softwareregister and display annotation. Integratedlow flow alarms for each sample flow Analyzerstatus fault flag 23 mA on mA output 1;Comprehensive analyzer status messagesappear on HMI display;Additional connection junction box requiredexternally

    Certification

    Hazardous areacertification

    ATEX II 2 G EExd IIB + H2 T4 Tamb =-40 to +60C

    CCSAUScertified to Class I, Div 1, Groups B, C& D, T4

    Transportable CD2 with Water DP (ISO18453) andmaterial certificates ATEX (230 V AC)

    CD2PSS-AT-HW-MC

    Transportable CD2 with Water DP (IGT#8) andmaterial certificates CSA (110 V AC)

    CD2PSS-CS-HW-MC

    Accessories

    Item Product / Description

    SSF-CF-LON-10PK Coalescing Filter Cartridge (pack of 10)

    Condumax II Transportable

    Order Codes