Upload
others
View
7
Download
0
Embed Size (px)
Citation preview
CA
BLE
TR
AY S
YS
TEM
S 2
014
GR
P
NX
007
5 01
_GB
Ebo Systems S.A.S.Zone Industrielle BP 5F-54920 Villers-la-Montagne
Tel: +33 382440107Fax: +33 382261041
GRP CABLE TRAY SYSTEMSGLASS REINFORCED POLYESTER
2014
GRP
ALL PRODUCTS ARE CERTIFIED
competent.innovative.
customized.
Ebo Systems Ebo SystemsEbo Systems
CA
BLE
TR
AY S
YS
TEM
S 2
014
GR
P
NX
007
5 01
_GB
Ebo Systems S.A.S.Zone Industrielle BP 5F-54920 Villers-la-Montagne
Tel: +33 382440107Fax: +33 382261041
GRP CABLE TRAY SYSTEMSGLASS REINFORCED POLYESTER
2014
GRP
ALL PRODUCTS ARE CERTIFIED
competent.innovative.
customized.
Ebo Systems Ebo SystemsEbo Systems
ICONS
Please ask for the Certifications VDE/UL
AL Aluminium (N = naturally anodized, * = powdercoated in RAL colors)P Electrotechnical Porcelain MS Brass CU Copper
E1 Material Code.: 1.4016Stainless SteelE2 Material Code.: 1.4310
Founded in 1959 in Switzerland ( Zurich), EBO Systems was one of the first companies in Europe to specialise in the design and manufacturing of profiles for the support and installation of electric cables.
In 1972, a new production facility, specialised in the production of cable management systems, was set up at Villers-La-Montagne in France, in order to face up the increasing demand from different markets.
Since 1980 EBO Systems continues to invest and evolves to provide the best solution for the market, in addition to the hot press moulding technique, EBO Systems introduced the pultrusion technique and become the only manufacturer to supply to the customer two ranges of products.
To expand its range of products it develops and standardizes a new mix halogen-free and self-extinguishing which generates very little smoke in case of fire hazard.
Always at the forefront of new technologies Ebo Systems invests in an automated production of hot press moulding to reduce manufacturing lead times, increase quality and get the most competitive prices.With always the same goal: the customer satisfaction.
Ebo Systems joined in 2010 the German Niedax Group, one of the leading specialists in steel cables trays, thus strengthening its international presence.
E3 Material Code.: 1.4301, 1.4303E5 Material Code.: 1.4571E6 Material Code.: 1.4529
E4 Material Code.: 1.4401, 1.4404 E7 Material Code.: 1.4547E8 Material Code.: 1.4430E9 Material Code.: 1.4362
Steel Ebo Systems, always ahead…
But it is also …
Projets…
B Steel, bareV Steel, galvanized according to DIN 50 961, blued G Steel, galvanized according to DIN 50 961, passivatedS Steel, pre-galvanized according to DIN EN 10 327F Steel, hot dip galvanized after fabrication (HDGAF) according to DIN EN ISO 1461 (Replacement for DIN 50 976)
Steel, black-oxide finishSB
All products in this catalog are classified according to the EAN code (13 digits). The first 7 digits indicate the country (40 = Germany) and the manufacturer‘s code (13339 = Niedax). The following six digits are the product code. example EAN code of the product TK = 40 60.85 13339 183708.
0914
E10 Material Code.: 1.4307E11 Material Code.: 1.4034
FG
COLOR Steel, pre-galvanized and powdercoated
Steel, geomet® galvanized
CDV Steel, wire galvanized
Hardware
Fast Install
Siderail Height in mm
Wire Diameter in mm
Info
New
Installation Instructions
Reference Note
Pipe Diameter in mm
Cover hole and depth in mm
Discontinued model
No halogen
No silicone
C R W L WA N PComplete model-No. white creme white light grey white aluminium aluminium aluminiumfor the colour RAL 9010 RAL 9001 RAL 7035 RAL 9006 natural anodized plate-finishedidentity on stock O t h e r R A L c o l o u r s o n r e q u e s t s . F o r p o s s i b l e c o l o u r d i v e r g e n c e s w e a s s u m e n o l i a b i l i t y .
From Paris to Singapore via Dubai, EBO Systems is present in more than 27 countries becoming the global supplier of your projects in energy, transport and industrial building.
An efficient customer servicewith a unique contact who takes in consideration the customers requests, needs, specifications for your national and international projects.
A Research & Development department Able to give advices and propose personal study upstream, during and after your project, and provide a technical assistance on-site.
A logistics departmentwith a good experience of delive-ries around the world.
Respect for the environnement Ebo Systems engages in environ-nemental quality certification Iso 14001 and proceeds to products recycling.
Ebo Systems are tools of advanced production technology, combined with human expertise to over 50 years ...
STANDARD COLORES SURFACE IN ALUMINUM
F8 Steel, mechanical zinc plated / passivatedHigh quality coating. Corrosion resistance measured by means of a test salt spray according to DIN 50 021 (ASTM-B117-90) is at least 500 hours.
F9
F10
Steel, mechanical zinc plated / passivatedHigh quality coating. Corrosion resistance measured by means of a test salt spray according to DIN 50021 (ASTM-B117-90) is at least 600 hours.Steel, electrical mechanical / passivatedZinc coating thickness of 5 microns, electrolytically applied and clear passivated according to BS EN 12329 2000 FE/ZN5//A.
F6 Natural colorUntreated material against corrosion.
F7 Steel, plastic coatingEVA (Ethylene Vinyl Acetate Copolymer Saponifies) Levasint ®) resistance to fire according to DIN 4102.
F1 Steel, zinc coating and chromateSteel, zinc coating & chromate Thickness of zinc is between 8-12 microns, elec-trolytic galvanizing & additionally chromated. Corrosion resistance measured by using a salt spray test according to DIN 50021 (ASTM-B117-90) at least 72 hours.
F2 Steel, hot dip galvanizedThickness of zinc between 50-70 microns, after immersion machining in a bath of molten zinc.
F3 Stainless steel (material number. 1.4401 [316])Indoor use / Outdoor in humid environments and moderately aggressive.
F5 BrassFor indoor use only.
F4 Steel, coatedDekor-lacquer interior use in dry environments and not corrosive.
K10 PVC - PolyvinylchlorideK21 PUR - Polyurethane
K11 ABS - Acrilonitrile-Butadiene-Styrene
K13
K14
K15
K16
K17
K18
K19
K20
K12
K22 PET - Polyethylene Terephtalate, halogen free
K23
C1
Sales conditions 1. Opposability These sales conditions are sent with our bid to all purchasers to raise an order. Consequently, raising an order implies full , unreserved acceptance of these conditions, excluding any other type of document such as a brochure or catalogue, which only give approximate information. No special condition can have priority over these conditions, except if formal written approval is received from Ebo Systems. Furthermore, the purchaser renounces his own general purchasing conditions. The fact that Ebo Systems does not invoke, at a given moment, one of the present conditions, cannot be interpreted as being a renunciation of future invocations of such a condition
2. Contract validity Bids by Ebo Systems are only valid for a duration of 2 (two) months unless specified otherwise. Orders are only definitively accepted when they have been confirmed in writing by Ebo Systems and where applicable, after payment of the agreed advance. The fact that the purchaser does not reply within 8 (eight) days following the sending of written conformation, is equal to express acceptance by the purchaser. Should an order that has become definitive be cancelled, the entire purchase price will be invoiced to the purchaser and become immediately payable. Ebo Systems none the less reserves the right, in case of a drop in the credit rating of the purchaser, or if Ebo Systems has legi timate reason to consider that the purchaser will be incapable of paying the purchase price at the agreed deadlines: • either to cancel an order in progress, even if definitive • or to demand first rate guarantees, or a payment before delivery, it being understood that payment means effective cashing of the payment instrument. The order is specifically intended for the purchaser and cannot be transferred without prior written approval from Ebo Systems.
3. Object of the delivery Ebo Systems reserves the right to make any change to the presentation, shape, size and design at any time it considers useful to its products without being obliged to modify ordered goods being manufactured. Ebo Systems also reserves the right to modify, without prior warning, the products defined in its pamphlets and catalogues. None the less, in case of changes to standards or improvements to products ordered before delivery Ebo Systems reserves the right to make the technical changes necessary without the object ordered being modified
4. Shipment Any increase to cost of shipment, to taxes or miscellaneous duties occurring during performance of the contract is entirely paid by the purchaser except if there are special or contrary provisions in the price legislation. Special packaging, maritime freight or insurance where applicable, shall be invoiced at the tariff in force at the moment of shipment
5. Delivery turnaround times 5.1 Delivery turnaround times are given for information purposes and are not guaranteed. Ebo Systems is authorized to make global or partial deliveries. Overshooting of delivery times cannot give rise to compensation and interest, nor discounts or cancellations of orders, unless contrary provisions are agreed in writing with the purchaser. Ebo Systems may be released from its commitment to deliver in case of force majeur. Without this list being comprehensive, force majeur includes: war, uprisings, strikes or combined action by the personnel of the suppliers of Ebo Systems or service suppliers Ebo Systems uses to carry out orders 5.2 In all cases, delivery within the agreed turnaround times can only take place if the purchaser has fully satisfied all his commitments to Ebo Systems, no matter what the reason, especially those resulting from article 2 of these conditions.
6. Delivery costs and risks Goods are delivered in compliance with Incoterms I.C.C. dated January 2000. As of the delivery, as defined in Article 4 of these conditions, the goods travel at the expense and risk of the purchaser, who is responsible in case of damage or missing articles to make any necessary reservations and to take all steps to preserve his rights of action against the shipper. The shipper designated by Ebo Systems, works on the behalf of, at the expense of and risk of the purchaser. Unless prior written instructions are received from the purchaser, repeated for each shipment and reception confirmed by Ebo Systems, Ebo Systems is not bound to take out any insurance, declaration of value or make any declaration of interest at delivery on behalf of the purchaser, no matter what might be the value of the goods shipped. The costs relating to the services undertaken by Ebo Systems on behalf of the purchaser are fully invoiced to the purchaser. In no case whatsoever can Ebo Systems be held responsible for the method of payment selected and the tariff applied by the shipper.
7. Reception Notwithstanding any prejudice to the measures to take with regard to the shipper, claims for missing articles, visible defects or non-compliance of goods delivered with regard to goods ordered or the bill of lading, must be made in writing and sent by registered letter with acknowledgement, within 8 (eight) days following delivery of such goods. Beyond this period of time, no claim will be accepted. The purchaser shall leave Ebo Systems leeway to confirm these faults and to remedy them. The purchaser promises not to take any action himself, not bring in a third party for this purpose.
8. Return of products No return of products shall be carried out without prior written authorization from Ebo Systems. The cost and risk of return of products is always at the expense of the purchaser. In case of visible defects or the non-conformity of delivered goods, duly recorded by Ebo systems under the condition scheduled in Article 7 of these conditions, the purchaser may obtain reimbursement of the price paid, excluding any indemnity and compensation. On the other hand, if the claims made by the purchaser are not substantiated, Ebo Systems has the right to invoice him for all non-substantiated travel, goods inspection and transport expenses.
9. Guarantee Ebo Systems are ISO 9001 certified. Products are guaranteed against any functional fault for a duration of 6 (six) months as of the date of delivery. Under this guarantee, the only commitment encumbering Ebo Systems will be the reimbursement of the purchase price, excluding any compensation, no matter what it might be. In no case whatsoever can the liability of Ebo Systems exceed the price of the products. To be taken into account, any defective product under guaranteed must be returned at the expense and risk of the purchaser with a return note, once accepted by Ebo Systems.
10. Guarantee exclusions Any demand with an aim to implementing the guarantee can only be accepted if the purchaser is up to date with his financial commitments with regard to Ebo Systems. Defects and damage caused by normal wear, accidental causes, negligence, malicious intent, implementation not in compliance with good works practice, protection and safety standards, regulations in force, repair by third parties or even defective maintenance shall be excluded from the guarantee.
11. Price Products are provided at the price rate in force on the date of the order. Prices are net, ex plant, special packaging in addition.
12. Payment methods Invoices are payable cash on reception, by check, signed and accepted letter of credit, protest not being necessary or any other accepted method of payment. In case of payment by letters of credit, the purchaser is bound to return the letters accepted and signed within a maximum of 7 (seven) days. Payment according to these general sales conditions is not simply the fact of paying by check or by letter of credit, but its effective cashing at the scheduled date. Any drop to the purchaser credit rating may substantiate the demand for first rate guarantees or cash payment when ordering or payment by sight draft prior to execution of orders received or before the due date of issued invoices. Ebo Systems reserves the right at all times, according to the risks involved, to set a maximum credit allowance for each purchaser, it being understood that these modalities are valid for all orders in progress. The refusal by the purchaser to meet these conditions gives Ebo Systems the right either to cancel all or part of the orders or to demand immediate payment of all sums due.
13. Late payment or failure to pay In case of late payment, Ebo Systems may suspend all orders in progress without any prejudice to any other means of action. Any sum not paid at the scheduled payment time will give rise by full right and without any prior warning, to payment of late payment interest at a rate equal to one and a half times the legal interest rate in force in France, from the due date up to the payment date. In case of failure to pay forty-eight hours after formal notice without response, the sale shall be cancelled by full right if considered necessary by Ebo Systems, who can request restitution of products, without prejudice for other compensation. The resolution will not simply affect the order involved but also all previous orders whether delivered or being delivered and related payment, whether due or not. In case of payment by letter of credit, the returned letter shall be considered as a refusal to accept, assimilated to a failure to pay. Non-payment of a single invoice or at a payment date will result in the immediate payment of all sums due without other warnings. In all preceding cases, the sums due for other reasons or any other cause become immediately payable if Ebo Systems does not opt for the resolution of the corresponding orders. The purchaser shall reimburse, other than the principle and the interest, all expenses caused by the recovery by litigation of sums due, as well as a 15% (fifteen percent) penalty of the unpaid sum. In no case may payments be suspended or be the subject of any compensation without prior written approval from Ebo Systems. All partial payments shall first used to pay compensation and penalties, then the sums with the oldest due payment date. No failure to pay, or late payment, can be justif ied later by a claim. Lastly, reference to the stipulations made in Article 2 of these general sales conditions is made.
14. Transfer of risks Transfer of risks takes place as of the moment the goods are made available to the purchaser at a location agreed upon with Ebo Systems at the date, or within the stipulated time frame, or as of the moment such goods have been delivered to the terminal of the forwarder, agreed with the purchaser. As of this moment, the goods are shipped at the risk and the expense of the purchaser.
15. Right of ownership Ebo Systems reserves the ownership of delivered goods until the full payment of the sum due by the purchaser is received. The purchaser is bound to keep goods in perfect condition and to insure goods on behalf of the owner against all usual risks, especially loss, destruction or theft, with the indemnity being delegated in case of a problem to Ebo Systems. Ebo Systems must immediately be informed about any accident. The purchaser promises to immediately inform Ebo Systems in the case of settlement or judicial winding-up, in case of seizure or any other procedure initiated by a third party and to inform Ebo Systems of the exact location where delivered goods not yet paid for are stored. The purchaser promises not to use delivered unpaid for goods as security and in general not to carry out any operation likely to cause prejudice to the right of ownership of Ebo Systems. In case of resale of delivered goods, whether or not the purchaser is authorized, the purchaser declares now to declare to Ebo Systems the debt resulting from the sale to a sub-purchaser and authorizes Ebo Systems to cash the price paid by the sub-purchaser, up to the total sum of his debt with the purchaser. The purchaser promises to inform Ebo Systems immediately of the exact and complete identity of any sub-purchaser, who will be informed by the purchaser of the right of ownership by Ebo Systems, at the latest at the moment of signing the contract. Any violation by the purchaser with regard to the obligations stipulated in this clause or in the general sales conditions shall be sanctioned by full rights by the event of default. The claim by Ebo Systems to the goods of which the ownership is reserved is by means of registered letter with acknowledgement, sent to the purchaser, requiring him to return the goods in his possession to Ebo Systems. The claim of goods under reserve of ownership neither constitutes a resolution nor cancellation to the sales contract. The claim may be made by Ebo Systems in case of non-observance of any of the commitments by the purchaser, especially non-acceptance of a letter of credit, in which case Ebo Systems will have all legal rights to think that the purchaser is not capable of observing the agreed payment dates. All expenses caused by the claiming of goods or their corresponding sum are at the exclusive cost of the purchaser.
16. Court of competent jurisdiction and applicable law The court of competent jurisdiction is expressly allocated to the courts of BRIEY - France, who will decide on the application of French law unless Ebo Systems decides to nominate another court of competent jurisdiction.
ICONS
Please ask for the Certifications VDE/UL
AL Aluminium (N = naturally anodized, * = powdercoated in RAL colors)P Electrotechnical Porcelain MS Brass CU Copper
E1 Material Code.: 1.4016Stainless SteelE2 Material Code.: 1.4310
Founded in 1959 in Switzerland ( Zurich), EBO Systems was one of the first companies in Europe to specialise in the design and manufacturing of profiles for the support and installation of electric cables.
In 1972, a new production facility, specialised in the production of cable management systems, was set up at Villers-La-Montagne in France, in order to face up the increasing demand from different markets.
Since 1980 EBO Systems continues to invest and evolves to provide the best solution for the market, in addition to the hot press moulding technique, EBO Systems introduced the pultrusion technique and become the only manufacturer to supply to the customer two ranges of products.
To expand its range of products it develops and standardizes a new mix halogen-free and self-extinguishing which generates very little smoke in case of fire hazard.
Always at the forefront of new technologies Ebo Systems invests in an automated production of hot press moulding to reduce manufacturing lead times, increase quality and get the most competitive prices.With always the same goal: the customer satisfaction.
Ebo Systems joined in 2010 the German Niedax Group, one of the leading specialists in steel cables trays, thus strengthening its international presence.
E3 Material Code.: 1.4301, 1.4303E5 Material Code.: 1.4571E6 Material Code.: 1.4529
E4 Material Code.: 1.4401, 1.4404 E7 Material Code.: 1.4547E8 Material Code.: 1.4430E9 Material Code.: 1.4362
Steel Ebo Systems, always ahead…
But it is also …
Projets…
B Steel, bareV Steel, galvanized according to DIN 50 961, blued G Steel, galvanized according to DIN 50 961, passivatedS Steel, pre-galvanized according to DIN EN 10 327F Steel, hot dip galvanized after fabrication (HDGAF) according to DIN EN ISO 1461 (Replacement for DIN 50 976)
Steel, black-oxide finishSB
All products in this catalog are classified according to the EAN code (13 digits). The first 7 digits indicate the country (40 = Germany) and the manufacturer‘s code (13339 = Niedax). The following six digits are the product code. example EAN code of the product TK = 40 60.85 13339 183708.
0914
E10 Material Code.: 1.4307E11 Material Code.: 1.4034
FG
COLOR Steel, pre-galvanized and powdercoated
Steel, geomet® galvanized
CDV Steel, wire galvanized
Hardware
Fast Install
Siderail Height in mm
Wire Diameter in mm
Info
New
Installation Instructions
Reference Note
Pipe Diameter in mm
Cover hole and depth in mm
Discontinued model
No halogen
No silicone
C R W L WA N PComplete model-No. white creme white light grey white aluminium aluminium aluminiumfor the colour RAL 9010 RAL 9001 RAL 7035 RAL 9006 natural anodized plate-finishedidentity on stock O t h e r R A L c o l o u r s o n r e q u e s t s . F o r p o s s i b l e c o l o u r d i v e r g e n c e s w e a s s u m e n o l i a b i l i t y .
From Paris to Singapore via Dubai, EBO Systems is present in more than 27 countries becoming the global supplier of your projects in energy, transport and industrial building.
An efficient customer servicewith a unique contact who takes in consideration the customers requests, needs, specifications for your national and international projects.
A Research & Development department Able to give advices and propose personal study upstream, during and after your project, and provide a technical assistance on-site.
A logistics departmentwith a good experience of delive-ries around the world.
Respect for the environnement Ebo Systems engages in environ-nemental quality certification Iso 14001 and proceeds to products recycling.
Ebo Systems are tools of advanced production technology, combined with human expertise to over 50 years ...
STANDARD COLORES SURFACE IN ALUMINUM
F8 Steel, mechanical zinc plated / passivatedHigh quality coating. Corrosion resistance measured by means of a test salt spray according to DIN 50 021 (ASTM-B117-90) is at least 500 hours.
F9
F10
Steel, mechanical zinc plated / passivatedHigh quality coating. Corrosion resistance measured by means of a test salt spray according to DIN 50021 (ASTM-B117-90) is at least 600 hours.Steel, electrical mechanical / passivatedZinc coating thickness of 5 microns, electrolytically applied and clear passivated according to BS EN 12329 2000 FE/ZN5//A.
F6 Natural colorUntreated material against corrosion.
F7 Steel, plastic coatingEVA (Ethylene Vinyl Acetate Copolymer Saponifies) Levasint ®) resistance to fire according to DIN 4102.
F1 Steel, zinc coating and chromateSteel, zinc coating & chromate Thickness of zinc is between 8-12 microns, elec-trolytic galvanizing & additionally chromated. Corrosion resistance measured by using a salt spray test according to DIN 50021 (ASTM-B117-90) at least 72 hours.
F2 Steel, hot dip galvanizedThickness of zinc between 50-70 microns, after immersion machining in a bath of molten zinc.
F3 Stainless steel (material number. 1.4401 [316])Indoor use / Outdoor in humid environments and moderately aggressive.
F5 BrassFor indoor use only.
F4 Steel, coatedDekor-lacquer interior use in dry environments and not corrosive.
K10 PVC - PolyvinylchlorideK21 PUR - Polyurethane
K11 ABS - Acrilonitrile-Butadiene-Styrene
K13
K14
K15
K16
K17
K18
K19
K20
K12
K22 PET - Polyethylene Terephtalate, halogen free
K23
C1
Sales conditions 1. Opposability These sales conditions are sent with our bid to all purchasers to raise an order. Consequently, raising an order implies full , unreserved acceptance of these conditions, excluding any other type of document such as a brochure or catalogue, which only give approximate information. No special condition can have priority over these conditions, except if formal written approval is received from Ebo Systems. Furthermore, the purchaser renounces his own general purchasing conditions. The fact that Ebo Systems does not invoke, at a given moment, one of the present conditions, cannot be interpreted as being a renunciation of future invocations of such a condition
2. Contract validity Bids by Ebo Systems are only valid for a duration of 2 (two) months unless specified otherwise. Orders are only definitively accepted when they have been confirmed in writing by Ebo Systems and where applicable, after payment of the agreed advance. The fact that the purchaser does not reply within 8 (eight) days following the sending of written conformation, is equal to express acceptance by the purchaser. Should an order that has become definitive be cancelled, the entire purchase price will be invoiced to the purchaser and become immediately payable. Ebo Systems none the less reserves the right, in case of a drop in the credit rating of the purchaser, or if Ebo Systems has legi timate reason to consider that the purchaser will be incapable of paying the purchase price at the agreed deadlines: • either to cancel an order in progress, even if definitive • or to demand first rate guarantees, or a payment before delivery, it being understood that payment means effective cashing of the payment instrument. The order is specifically intended for the purchaser and cannot be transferred without prior written approval from Ebo Systems.
3. Object of the delivery Ebo Systems reserves the right to make any change to the presentation, shape, size and design at any time it considers useful to its products without being obliged to modify ordered goods being manufactured. Ebo Systems also reserves the right to modify, without prior warning, the products defined in its pamphlets and catalogues. None the less, in case of changes to standards or improvements to products ordered before delivery Ebo Systems reserves the right to make the technical changes necessary without the object ordered being modified
4. Shipment Any increase to cost of shipment, to taxes or miscellaneous duties occurring during performance of the contract is entirely paid by the purchaser except if there are special or contrary provisions in the price legislation. Special packaging, maritime freight or insurance where applicable, shall be invoiced at the tariff in force at the moment of shipment
5. Delivery turnaround times 5.1 Delivery turnaround times are given for information purposes and are not guaranteed. Ebo Systems is authorized to make global or partial deliveries. Overshooting of delivery times cannot give rise to compensation and interest, nor discounts or cancellations of orders, unless contrary provisions are agreed in writing with the purchaser. Ebo Systems may be released from its commitment to deliver in case of force majeur. Without this list being comprehensive, force majeur includes: war, uprisings, strikes or combined action by the personnel of the suppliers of Ebo Systems or service suppliers Ebo Systems uses to carry out orders 5.2 In all cases, delivery within the agreed turnaround times can only take place if the purchaser has fully satisfied all his commitments to Ebo Systems, no matter what the reason, especially those resulting from article 2 of these conditions.
6. Delivery costs and risks Goods are delivered in compliance with Incoterms I.C.C. dated January 2000. As of the delivery, as defined in Article 4 of these conditions, the goods travel at the expense and risk of the purchaser, who is responsible in case of damage or missing articles to make any necessary reservations and to take all steps to preserve his rights of action against the shipper. The shipper designated by Ebo Systems, works on the behalf of, at the expense of and risk of the purchaser. Unless prior written instructions are received from the purchaser, repeated for each shipment and reception confirmed by Ebo Systems, Ebo Systems is not bound to take out any insurance, declaration of value or make any declaration of interest at delivery on behalf of the purchaser, no matter what might be the value of the goods shipped. The costs relating to the services undertaken by Ebo Systems on behalf of the purchaser are fully invoiced to the purchaser. In no case whatsoever can Ebo Systems be held responsible for the method of payment selected and the tariff applied by the shipper.
7. Reception Notwithstanding any prejudice to the measures to take with regard to the shipper, claims for missing articles, visible defects or non-compliance of goods delivered with regard to goods ordered or the bill of lading, must be made in writing and sent by registered letter with acknowledgement, within 8 (eight) days following delivery of such goods. Beyond this period of time, no claim will be accepted. The purchaser shall leave Ebo Systems leeway to confirm these faults and to remedy them. The purchaser promises not to take any action himself, not bring in a third party for this purpose.
8. Return of products No return of products shall be carried out without prior written authorization from Ebo Systems. The cost and risk of return of products is always at the expense of the purchaser. In case of visible defects or the non-conformity of delivered goods, duly recorded by Ebo systems under the condition scheduled in Article 7 of these conditions, the purchaser may obtain reimbursement of the price paid, excluding any indemnity and compensation. On the other hand, if the claims made by the purchaser are not substantiated, Ebo Systems has the right to invoice him for all non-substantiated travel, goods inspection and transport expenses.
9. Guarantee Ebo Systems are ISO 9001 certified. Products are guaranteed against any functional fault for a duration of 6 (six) months as of the date of delivery. Under this guarantee, the only commitment encumbering Ebo Systems will be the reimbursement of the purchase price, excluding any compensation, no matter what it might be. In no case whatsoever can the liability of Ebo Systems exceed the price of the products. To be taken into account, any defective product under guaranteed must be returned at the expense and risk of the purchaser with a return note, once accepted by Ebo Systems.
10. Guarantee exclusions Any demand with an aim to implementing the guarantee can only be accepted if the purchaser is up to date with his financial commitments with regard to Ebo Systems. Defects and damage caused by normal wear, accidental causes, negligence, malicious intent, implementation not in compliance with good works practice, protection and safety standards, regulations in force, repair by third parties or even defective maintenance shall be excluded from the guarantee.
11. Price Products are provided at the price rate in force on the date of the order. Prices are net, ex plant, special packaging in addition.
12. Payment methods Invoices are payable cash on reception, by check, signed and accepted letter of credit, protest not being necessary or any other accepted method of payment. In case of payment by letters of credit, the purchaser is bound to return the letters accepted and signed within a maximum of 7 (seven) days. Payment according to these general sales conditions is not simply the fact of paying by check or by letter of credit, but its effective cashing at the scheduled date. Any drop to the purchaser credit rating may substantiate the demand for first rate guarantees or cash payment when ordering or payment by sight draft prior to execution of orders received or before the due date of issued invoices. Ebo Systems reserves the right at all times, according to the risks involved, to set a maximum credit allowance for each purchaser, it being understood that these modalities are valid for all orders in progress. The refusal by the purchaser to meet these conditions gives Ebo Systems the right either to cancel all or part of the orders or to demand immediate payment of all sums due.
13. Late payment or failure to pay In case of late payment, Ebo Systems may suspend all orders in progress without any prejudice to any other means of action. Any sum not paid at the scheduled payment time will give rise by full right and without any prior warning, to payment of late payment interest at a rate equal to one and a half times the legal interest rate in force in France, from the due date up to the payment date. In case of failure to pay forty-eight hours after formal notice without response, the sale shall be cancelled by full right if considered necessary by Ebo Systems, who can request restitution of products, without prejudice for other compensation. The resolution will not simply affect the order involved but also all previous orders whether delivered or being delivered and related payment, whether due or not. In case of payment by letter of credit, the returned letter shall be considered as a refusal to accept, assimilated to a failure to pay. Non-payment of a single invoice or at a payment date will result in the immediate payment of all sums due without other warnings. In all preceding cases, the sums due for other reasons or any other cause become immediately payable if Ebo Systems does not opt for the resolution of the corresponding orders. The purchaser shall reimburse, other than the principle and the interest, all expenses caused by the recovery by litigation of sums due, as well as a 15% (fifteen percent) penalty of the unpaid sum. In no case may payments be suspended or be the subject of any compensation without prior written approval from Ebo Systems. All partial payments shall first used to pay compensation and penalties, then the sums with the oldest due payment date. No failure to pay, or late payment, can be justif ied later by a claim. Lastly, reference to the stipulations made in Article 2 of these general sales conditions is made.
14. Transfer of risks Transfer of risks takes place as of the moment the goods are made available to the purchaser at a location agreed upon with Ebo Systems at the date, or within the stipulated time frame, or as of the moment such goods have been delivered to the terminal of the forwarder, agreed with the purchaser. As of this moment, the goods are shipped at the risk and the expense of the purchaser.
15. Right of ownership Ebo Systems reserves the ownership of delivered goods until the full payment of the sum due by the purchaser is received. The purchaser is bound to keep goods in perfect condition and to insure goods on behalf of the owner against all usual risks, especially loss, destruction or theft, with the indemnity being delegated in case of a problem to Ebo Systems. Ebo Systems must immediately be informed about any accident. The purchaser promises to immediately inform Ebo Systems in the case of settlement or judicial winding-up, in case of seizure or any other procedure initiated by a third party and to inform Ebo Systems of the exact location where delivered goods not yet paid for are stored. The purchaser promises not to use delivered unpaid for goods as security and in general not to carry out any operation likely to cause prejudice to the right of ownership of Ebo Systems. In case of resale of delivered goods, whether or not the purchaser is authorized, the purchaser declares now to declare to Ebo Systems the debt resulting from the sale to a sub-purchaser and authorizes Ebo Systems to cash the price paid by the sub-purchaser, up to the total sum of his debt with the purchaser. The purchaser promises to inform Ebo Systems immediately of the exact and complete identity of any sub-purchaser, who will be informed by the purchaser of the right of ownership by Ebo Systems, at the latest at the moment of signing the contract. Any violation by the purchaser with regard to the obligations stipulated in this clause or in the general sales conditions shall be sanctioned by full rights by the event of default. The claim by Ebo Systems to the goods of which the ownership is reserved is by means of registered letter with acknowledgement, sent to the purchaser, requiring him to return the goods in his possession to Ebo Systems. The claim of goods under reserve of ownership neither constitutes a resolution nor cancellation to the sales contract. The claim may be made by Ebo Systems in case of non-observance of any of the commitments by the purchaser, especially non-acceptance of a letter of credit, in which case Ebo Systems will have all legal rights to think that the purchaser is not capable of observing the agreed payment dates. All expenses caused by the claiming of goods or their corresponding sum are at the exclusive cost of the purchaser.
16. Court of competent jurisdiction and applicable law The court of competent jurisdiction is expressly allocated to the courts of BRIEY - France, who will decide on the application of French law unless Ebo Systems decides to nominate another court of competent jurisdiction.
are characterized by their extreme resistance because no other material is as strong as fi berglass reinforced polyesterIn extreme conditions such as heat, sunlight (UV), cold or exposure to chemicals, material performs its function and formany years.
The support systems of glass fi ber cables offer maximum fl exibility and effi ciency. The wide range of products can meet the different applications of cables trays systems. A full range of standard fi ttings allows easy many confi gurations. Special sizes are available on demand.
Ebo has been certifi ed since 1994 according to ISO 9001.What does this mean for you as a client:
In the treatment of our products PRV, we recommend the use of protective clothing: gloves, goggles, mask, long-sleeved shirts and cottontrousers, to avoid possible skin irritation by dust.!
Cable tray systemsin Glass Reinforced Polyester
• Ongoing evaluation and classifi cation of suppliers• The systematic control of raw materials and semi-fi nished goods receipt• A regular review of technical data of materials in the laboratory• Perfect control of the manufacturing• Monitoring of the manufacturing process• fi nal inspection before shipment Other certifi cations are available on our web site: www.ebo-systems.com
GFKHigh temperature resistance (-80 ° C à +130 ° C)
• high mechanical resistance
• high chemical resistance
• high dielectric strength
• Corrosion resistance
• extremely insulating material
• halogen free
• UV resistance
• food security
• low weight
• low thermal conductivity
• simple and without burr when changes
• extraordinary long lifetime
• self-extinguishing material
• no electrolytic corrosion
• no need to earth
• without toxic fumes
• optimal transportation and handling
Qualities and advantages
mechanical resistance thanks to a mixture of special resinmade of pressed polyester reinforced with fi berglassInterlocking and self-adjustable coupling, no screws required19 dimensions of cable trays available from stock perforated or not perforated188 fi ttings availablesupporting distance of maximum 1,5 m
Cable tray systems K²
Application areas wastewater treatment plant, chemical, offshore, tunnels, solar and photovoltaic installations, industrial facilities, power plants, mines,farms and food production.
Available in widths50 - 600 mm
20 50 80 110K23
made of pultruded polyester reinforced with fi berglassQuick assembly with clip in jointing piecesExpansion joint automatically setCable trays with or without perforationsFast fi x clip on lidssupporting distance of maximum 4 m
Cable tray systems KP
Application areas wastewater treatment plant, chemical, offshore, tunnels, solar and photovoltaic installations, industrial facilities, power plants, mines,farms and food production.
K23 50 80 40 Available in widths60 - 300 mm
made of pultruded polyester reinforced with fi berglass30 dimensions of cable ladders available from stock perforated or not perforatedDelivered assembledPossibility of on-site assembly, signifi cant reduction in transport costsUnique patented clip-in rungs assembly, without metallic or thermoplastic partsNo risk to damage cables when pulling them into the laddersBetter resistance to vibrationsReversed rungs availableFittings available in all dimensionsSupporting distance of maximum 6 m
Cable ladder systems UL 53 80 100 150K23Available in widths150 - 900 mm
Application areaswastewater treatment plant, chemical, offshore, tunnels, solar and photovoltaic installations, industrial facilities, power plants, mines,farms and food production.
SYSTEMS OVERVIEW
made in pultruded polyester reinforced with fi berglass8 dimensions availablemaintenance of cables through a system of clampsextremely resistant
Trunking system LFG 40 50 80K23
Application areasamong others: water treatment plants, sewage farms and food production, refi neries, oil & gas platforms,Off Shore, solar and photovoltaic installation, Tunnel
Available in widths57 - 300 mm
Ground ducts Press moulded GRP BK/BKS 140 155 176 191K23Available in widths200 - 400 mm
made in pressed polyester reinforced with fi berglassInterlocking and self-adjustable coupling, no screws requiredAnchor attachement in concrete pre-mountedExtremely impact and frost-resistant
Application areasamong others: business bridge construction, tunnel, mining and port facilities.
Stand-System SPmade in pultruded polyester reinforced with fi berglassinsulating, no need to earthslightresistant short circuit of 30 kV, certifi cate provided by IPH Berlin
Application areasamong others: railways, trains, subways
K23 150 Available in widths150 und 250 mm
made in pultruded polyester reinforced with fi berglassfi re retardantself-extinguishing materiallow thermal conductivitymaximal supporting distance 1.5mcertifi ed E30, conform to the standard DIN 4105-12
Application areasamong others: industrial plants railways, and road tunnels
Cable tray handrail systems MC K23
53 53
NOTES
Alphabetical table of contents page 6Type listing page 8-12
Support system Support and bracket Profi l Bracket Fixing plates
Cable tray system K2
Cable trays Covers Separators Accessoires Fittings
Cable tray system KP Cable trays Covers Separators Accessoires Fittings
Cable ladder system UL Cable ladders Covers Separators Accessoires Fittings
Trunking system LFG Wall mounted cable tray Separators Fittings
Ground ducts BK/BKS Cable trays Covers Separators Accessoires
Cable troughing SPLong span aerial cable trays
Handrail system MC Handrail profi l End fi ttings Accessories
Information Thermoset resins Plastic Zinc plating technique
KKKK2
KPKPKPKPULULULULLFGLFGLFGLFGLFGBK/BKSBK/BKSBK/BKSBK/BKSBK/BKSBK/BKSSPSPSPSPMCMCINFOThermoset resins INFOThermoset resins
TK
i
TABLE OF CONTENTS IN ALPHABETICAL ORDER
6
Anchor bolt 24A
Anchor fixing plate included bolts 23
Bolt 98B
Cable tray for a ground installation 111C
Ceiling support 20, 24Ceiling support and wall bracket 17Ceiling support profile 21-22Clipsable handrail end cap 124Clipsable splice plate 59, 63, 103,
126Cover fixing 50, 69, 97, 99,
110-111Cover fixing clip 50-51, 69, 96,
110Cover for cable ground duct 110Cover for cable trays and cable ladders 46, 94Cover for horizontal elbow 90° 94Cover for horizontal elbow 90°, large radius 46, 66Cover for horizontal elbow 90°, small radius 47
Dome head bolt 52, 70, 98D
End cap for cable tray 59, 63, 104E
End cap for GRP cable ladder 76, 80, 84, 89End cap for GRP cable tray 30, 35, 40End cap, (clippable) 126
Fork-type self-locking plier 99F
GRP adjustable elbow 78, 82, 87, 92G
GRP adjustable splice plate 31, 35, 40GRP bracket 18-19GRP cable ladders 76, 80, 84, 89GRP cable trays 30, 35, 40, 58,
62GRP changing elevation 33, 38, 43, 60,
64GRP cover for cable tray 66GRP cover for changing elevation 48-49, 67-68GRP cover for cross 96GRP cover for horizontal elbow 45°, small radius 46, 66GRP cover for left hand reduction 50, 69GRP cover for right hand reduction 50, 68GRP cover for tee junction 96GRP cover for tee junction, large radius 49, 68GRP cover for vertical adjustable elbow 94-95GRP cover for vertical inside elbow 47, 66-67GRP cover for vertical outside elbow 48, 67GRP cross for cable ladder 77, 81, 86, 91GRP elbow 45°, small radius 60, 63GRP elbow 90° 78, 82, 86, 91GRP elbow 90°, large radius 60, 64GRP fixing rail 25GRP ground duct 109GRP horizontal splice plate 76, 80, 85, 90GRP left hand reduction 32, 38, 42GRP right hand reduction 32, 37, 42GRP separator 31, 36, 41, 77,
81, 85, 90,104, 109
GRP support 19
GRP tee junction cable ladder 77, 81, 85, 90G
GRP tee junction for cable tray, large radius 31, 36, 41, 63GRP tee junction for cable tray, small radius 31, 36GRP tee junction, small radius 59GRP trunking 103GRP vertical adjustable or vertical fixed anglesplice plate
79, 83, 92
GRP vertical adjustable or with fixed angle spliceplate
87
GRP vertical inside elbow 33, 39, 43, 60,64
GRP vertical outside elbow 34, 39, 43, 61,64
GRP vertical splice plate 33, 38, 42
Handrail 123-124, 126H
Handrail end cap 123Hanger 21Hanger and wall bracket 17Hexagon head bolt 52, 70, 98Hold down clamp for cables 103Hold down clamp for cables E30 125Horizontal elbow 45° 32, 37, 41Horizontal elbow 90° 105Horizontal elbow 90°, large radius 32, 37, 42Horizontal elbow 90°, small radius 32, 37, 41Horizontal splice plate 31, 36, 41Horizontal stainless steel splice plate 77, 81, 85, 90
Ladder fixing hold down clamp 98L
Lighting support 125
Mounting plate 34, 39, 44M
Polyamid bolt 123P
Profile U 5050 22-23Protective end cap 18, 21
Rack for cables 70R
Reducer 78, 82, 87, 92Riveted handrail end cap 124
Separating stud 52, 70S
Separator 59, 63Splice plate 59, 123Stainless steel vertical splice plate V4A 33, 38, 42Steel cover for cable tray 111Steel tape for cover 97
Tee junction cover, small radius 49, 68T
The half end cap must be clipped 125The half end cap must be riveted 124
Vertical inside elbow 90° 104V
Vertical outside elbow 90° 104Vertical splice plate 79, 83, 88, 93
Wall-mounted angle plate 96, 99, 123W
Wall-mounted angle plate E30 126
51
Fixation de couvercle
Utilisable pour : Couvercles de chemins de câbles KKD... et KPD...Couvercle des pièces de forme KKCD..., KKBD..., KKWD..., KKBAD..., KKBID...,KKETD..., KKSTD..., KKSSD..., KKRLD... und KKRRD..
DF M
K01
Réf. Art. Coli-sage mini.
50 p.
CodeEAN
957927
Poids100uni.
pc.
kg
0,2
Pour la fixation du couvercle, il est necessaire de percer un trou de diamètre 8,2 mm. Dans desconditions difficiles, comme par exemple en cas de vents forts, il faudra augmenter le nombre defixations.
Fixation de couvercle
Utilisable pour : Couvercles de chemins de câbles KKD... et KPD...Couvercle des pièces de forme KKCD..., KKBD..., KKWD..., KKBAD..., KKBID...,KKETD..., KKSTD..., KKSSD..., KKRLD... und KKRRD..
DFUB 5.5X19 E4
N E4
Réf. Art. Coli-sage mini.
CodeEAN
062065
Poids100uni.
kg
0,64
Pour la fixation du couvercle, il est necessaire de percer un trou de diamètre 8,2 mm. Dans desconditions difficiles, comme par exemple en cas de vents forts, il faudra augmenter le nombre defixations.
Clip de fixation de couvercleinox
pour la fixation des couvercles de chemins de câbles et des pièces de forme
Utilisable pour : Couvercles de chemins de câbles KKD...
DF 1060 E4
E4
Réf. Art. Coli-sage mini.
50 p.
CodeEAN
957910
Poids100uni.
pc.
kg
1,1
Lors de la fixation, dans des conditions normales, il faut prendre soin de monter un clip par m enquiconce. Dans des conditions difficiles, comme par exemple en cas de vents forts, il faudraaugmenter le nombre de clips.
NOTES
7
8
Nr. de modéle Code EAN Page952991 109BK 140.200953004 109BK 176.300953011 109BK 176.400956029 110BKDR 200956043 111BKDR 200-5 F956074 111BKDR 200-8 F956036 110BKDR 300956050 111BKDR 300-5 F956081 111BKDR 300-8 F948543 110BKDR 400956067 111BKDR 400-5 F956098 111BKDR 400-8 F968336 98BKM 6X30 E4962303 111BKS 155.200962310 111BKS 191.300962327 111BKS 191.400057672 109BKT 140057689 109BKT 140/M057696 109BKT 176057719 109BKT 176/M957897 50DF 100 E4957897 96DF 100 E4957910 51DF 1060 E4957903 96DF 150 E4957873 50DF 50 E4957873 69DF 50 E4957873 96DF 50 E4957880 50DF 80 E4957880 69DF 80 E4957880 96DF 80 E4948550 110DF 94-4 E4957866 110DF 94-C E4957927 50DF M957927 69DF M957927 99DF M957927 110DF M062065 50DFUB 5.5X19 E4062065 69DFUB 5.5X19 E4062065 97DFUB 5.5X19 E4062065 111DFUB 5.5X19 E4968145 97DFW 100.150968152 97DFW 100.200968169 97DFW 100.300968176 97DFW 100.400968183 97DFW 100.450968190 97DFW 100.500968206 97DFW 100.600968213 97DFW 100.750968220 97DFW 100.900968237 97DFW 150.150968244 97DFW 150.200968251 97DFW 150.300968268 97DFW 150.400968275 97DFW 150.450968282 97DFW 150.500968299 97DFW 150.600968305 97DFW 150.750968312 97DFW 150.900968022 97DFW 53.150968039 97DFW 53.200968046 97DFW 53.300968053 97DFW 53.400968060 97DFW 53.500968077 97DFW 53.600968084 97DFW 80.150968091 97DFW 80.200968107 97DFW 80.300968114 97DFW 80.400968121 97DFW 80.500968138 97DFW 80.600962693 52FKM 6X16 E4962693 70FKM 6X16 E4962693 98FKM 6X16 E4962709 52FKM 6X20 E4962709 70FKM 6X20 E4962709 98FKM 6X20 E4962716 52FKM 8X20 K01962716 70FKM 8X20 K01962716 98FKM 8X20 K01955848 18FPAM 100955855 18FPAM 150
Nr. de modéle Code EAN Page955862 18FPAM 200955879 18FPAM 300955725 18FPAP 100/AC955732 18FPAP 150/AC955749 18FPAP 200/AC955756 18FPAP 250/AC955763 18FPAP 300/AC955770 18FPAP 400/AC955787 18FPAP 500/AC955794 18FPAP 600/AC955985 25FPAR 1000/AC955992 25FPAR 2000/AC955961 25FPAR 500/AC955978 25FPAR 750/AC962662 24FPBGV 10 E4963102 19FPCO 100/AC963119 19FPCO 150/AC963126 19FPCO 200/AC963133 19FPCO 300/AC955886 24FPDS 200/AC955893 24FPDS 300/AC955909 24FPDS 400/AC955916 24FPDS 500/AC955923 24FPES 200/AC955930 24FPES 300/AC955947 24FPES 400/AC955954 24FPES 500/AC963140 19FPPS967056 22HDS 50.50 C1KG962266 21HDS 50.50 E5931705 21HDS 50.50 F858880 20HU 5050/1000967063 21HU 5050/1000 C1KG965960 20{HU 5050/1000 E5}858903 20HU 5050/1100967070 21HU 5050/1100 C1KG858927 20HU 5050/1200967087 21HU 5050/1200 C1KG858941 20HU 5050/1500967094 21HU 5050/1500 C1KG858705 20HU 5050/200967100 21HU 5050/200 C1KG945757 20{HU 5050/200 E5}858965 20HU 5050/2000967117 21HU 5050/2000 C1KG858729 20HU 5050/250967124 21HU 5050/250 C1KG858743 20HU 5050/300967131 21HU 5050/300 C1KG945702 20{HU 5050/300 E5}858767 20HU 5050/400967148 21HU 5050/400 C1KG945764 20{HU 5050/400 E5}858781 20HU 5050/500967155 21HU 5050/500 C1KG945771 20{HU 5050/500 E5}858804 20HU 5050/600967162 21HU 5050/600 C1KG945788 20{HU 5050/600 E5}858828 20HU 5050/700967179 21HU 5050/700 C1KG858842 20HU 5050/800967186 21HU 5050/800 C1KG965953 20{HU 5050/800 E5}858866 20HU 5050/900967193 21HU 5050/900 C1KG347025 21K 5050347056 18KA 100-600952144 40KK 110.100952151 40KK 110.200952168 40KK 110.300952175 40KK 110.400952182 40KK 110.500952199 40KK 110.600952007 30KK 20.050952014 30KK 50.050952021 30KK 50.100952038 30KK 50.150952045 30KK 50.200952052 30KK 50.300952069 35KK 80.100
Nr. de modéle Code EAN Page952076 35KK 80.150952083 35KK 80.200952090 35KK 80.250952106 35KK 80.300952113 35KK 80.400952120 35KK 80.500952137 35KK 80.600953288 42KKB 110.100953295 42KKB 110.200953301 42KKB 110.300953318 42KKB 110.400953325 42KKB 110.500953332 42KKB 110.600953165 32KKB 50.100953172 32KKB 50.150953189 32KKB 50.200953196 32KKB 50.300953202 37KKB 80.100953219 37KKB 80.150953226 37KKB 80.200953233 37KKB 80.250953240 37KKB 80.300953257 37KKB 80.400953264 37KKB 80.500953271 37KKB 80.600953967 43KKBA 110.100953974 43KKBA 110.200953981 43KKBA 110.300953998 43KKBA 110.400954001 43KKBA 110.500954018 43KKBA 110.600953837 34KKBA 50.050953844 34KKBA 50.100953851 34KKBA 50.150953868 34KKBA 50.200953875 34KKBA 50.300953882 39KKBA 80.100953899 39KKBA 80.150953905 39KKBA 80.200953912 39KKBA 80.250953929 39KKBA 80.300953936 39KKBA 80.400953943 39KKBA 80.500953950 39KKBA 80.600956753 48KKBAD 110.100956760 48KKBAD 110.200956777 48KKBAD 110.300956784 48KKBAD 110.400956791 48KKBAD 110.500956807 48KKBAD 110.600956623 48KKBAD 50.050956623 67KKBAD 50.050956630 48KKBAD 50.100956630 67KKBAD 50.100956647 48KKBAD 50.150956647 67KKBAD 50.150956654 48KKBAD 50.200956654 67KKBAD 50.200956661 48KKBAD 50.300956661 67KKBAD 50.300956678 48KKBAD 80.100956678 67KKBAD 80.100956685 48KKBAD 80.150956685 67KKBAD 80.150956692 48KKBAD 80.200956692 67KKBAD 80.200956708 48KKBAD 80.250956708 67KKBAD 80.250956715 48KKBAD 80.300956715 67KKBAD 80.300956722 48KKBAD 80.400956722 67KKBAD 80.400956739 48KKBAD 80.500956739 67KKBAD 80.500956746 48KKBAD 80.600956746 67KKBAD 80.600956371 46KKBD 100956371 66KKBD 100956388 46KKBD 150956388 66KKBD 150956395 46KKBD 200
LIST OF ITEMS
model no. EAN code model no. EAN code model no. EAN code
9
Nr. de modéle Code EAN Page956395 66KKBD 200956401 46KKBD 250956401 66KKBD 250956418 46KKBD 300956418 66KKBD 300956425 46KKBD 400956425 66KKBD 400956432 46KKBD 500956432 66KKBD 500956449 46KKBD 600956449 66KKBD 600954155 43KKBI 110.100954162 43KKBI 110.200954179 43KKBI 110.300954186 43KKBI 110.400954193 43KKBI 110.500954209 43KKBI 110.600954025 33KKBI 50.050954032 33KKBI 50.100954049 33KKBI 50.150954056 33KKBI 50.200954063 33KKBI 50.300954070 39KKBI 80.100954087 39KKBI 80.150954094 39KKBI 80.200954100 39KKBI 80.250954117 39KKBI 80.300954124 39KKBI 80.400954131 39KKBI 80.500954148 39KKBI 80.600956944 47KKBID 110.100956951 47KKBID 110.200956968 47KKBID 110.300956975 47KKBID 110.400956982 47KKBID 110.500956999 47KKBID 110.600956814 47KKBID 50.050956814 66KKBID 50.050956821 47KKBID 50.100956821 66KKBID 50.100956838 47KKBID 50.150956838 66KKBID 50.150956845 47KKBID 50.200956845 66KKBID 50.200956852 47KKBID 50.300956852 66KKBID 50.300956869 47KKBID 80.100956869 67KKBID 80.100956876 47KKBID 80.150956876 67KKBID 80.150956883 47KKBID 80.200956883 67KKBID 80.200956890 47KKBID 80.250956890 67KKBID 80.250956906 47KKBID 80.300956906 67KKBID 80.300956913 47KKBID 80.400956913 67KKBID 80.400956920 47KKBID 80.500956920 67KKBID 80.500956937 47KKBID 80.600956937 67KKBID 80.600953523 41KKC 110.100953530 41KKC 110.200953547 41KKC 110.300953554 41KKC 110.400953561 41KKC 110.500953578 41KKC 110.600953400 32KKC 50.100953417 32KKC 50.150953424 32KKC 50.200953431 32KKC 50.300953448 37KKC 80.100953455 37KKC 80.150953462 37KKC 80.200953479 37KKC 80.250953486 37KKC 80.300953493 37KKC 80.400953509 37KKC 80.500953516 37KKC 80.600956456 46KKCD 100
Nr. de modéle Code EAN Page956456 66KKCD 100956463 46KKCD 150956463 66KKCD 150956470 46KKCD 200956470 66KKCD 200956487 46KKCD 250956487 66KKCD 250956494 46KKCD 300956494 66KKCD 300956500 46KKCD 400956500 66KKCD 400956517 46KKCD 500956517 66KKCD 500956524 46KKCD 600956524 66KKCD 600956111 46KKD 100956111 94KKD 100956128 46KKD 150956128 94KKD 150956135 46KKD 200956135 94KKD 200956142 46KKD 250956142 94KKD 250956159 46KKD 300956159 94KKD 300956166 46KKD 400956166 94KKD 400956173 94KKD 450956104 94KKD 50956180 46KKD 500956180 94KKD 500956197 46KKD 600956197 94KKD 600956210 94KKD 750956234 94KKD 900954452 43KKET 110.100954469 43KKET 110.200954476 43KKET 110.300954483 43KKET 110.400954490 43KKET 110.500954506 43KKET 110.600954339 33KKET 50.100954346 33KKET 50.150954353 33KKET 50.200954360 33KKET 50.300954377 38KKET 80.100954384 38KKET 80.150954391 38KKET 80.200954407 38KKET 80.250954414 38KKET 80.300954421 38KKET 80.400954438 38KKET 80.500954445 38KKET 80.600957125 49KKETD 110.100957132 49KKETD 110.200957149 49KKETD 110.300957156 49KKETD 110.400957163 49KKETD 110.500957170 49KKETD 110.600957002 48KKETD 50.100957002 67KKETD 50.100957019 48KKETD 50.150957019 67KKETD 50.150957026 48KKETD 50.200957026 67KKETD 50.200957033 48KKETD 50.300957033 67KKETD 50.300957040 49KKETD 80.100957040 68KKETD 80.100957057 49KKETD 80.150957057 68KKETD 80.150957064 49KKETD 80.200957064 68KKETD 80.200957071 49KKETD 80.250957071 68KKETD 80.250957088 49KKETD 80.300957088 68KKETD 80.300957095 49KKETD 80.400957095 68KKETD 80.400957101 49KKETD 80.500957101 68KKETD 80.500
Nr. de modéle Code EAN Page957118 49KKETD 80.600957118 68KKETD 80.600955640 40KKGH 110955626 31KKGH 50955633 35KKGH 80955152 42KKGV 110955138 33KKGV 50955145 38KKGV 80955671 41KKIH 110 E4955657 31KKIH 50 E4955664 36KKIH 80 E4955183 42KKIV 110 E4955169 33KKIV 50 E4955176 38KKIV 80 E4955329 40KKKE 110.100955336 40KKKE 110.200955343 40KKKE 110.300955350 40KKKE 110.400955367 40KKKE 110.500955374 40KKKE 110.600955190 30KKKE 50.050955206 30KKKE 50.100955213 30KKKE 50.150955220 30KKKE 50.200955237 30KKKE 50.300955244 35KKKE 80.100955251 35KKKE 80.150955268 35KKKE 80.200955275 35KKKE 80.250955282 35KKKE 80.300955299 35KKKE 80.400955305 35KKKE 80.500955312 35KKKE 80.600952342 40KKL 110.100952359 40KKL 110.200952366 40KKL 110.300952373 40KKL 110.400952380 40KKL 110.500952397 40KKL 110.600952205 30KKL 20.050952212 30KKL 50.050952229 30KKL 50.100952236 30KKL 50.150952243 30KKL 50.200952250 30KKL 50.300952267 35KKL 80.100952274 35KKL 80.150952281 35KKL 80.200952298 35KKL 80.250952304 35KKL 80.300952311 35KKL 80.400952328 35KKL 80.500952335 35KKL 80.600962532 42KKRL 110.200954988 42KKRL 110.300954995 42KKRL 110.400955008 42KKRL 110.500955015 42KKRL 110.600954919 32KKRL 50.200954926 32KKRL 50.300954933 38KKRL 80.200954940 38KKRL 80.300954957 38KKRL 80.400954964 38KKRL 80.500954971 38KKRL 80.600957323 50KKRLD 200957323 69KKRLD 200957330 50KKRLD 300957330 69KKRLD 300957347 50KKRLD 400957347 69KKRLD 400957354 50KKRLD 500957354 69KKRLD 500957361 50KKRLD 600957361 69KKRLD 600962549 42KKRR 110.200955091 42KKRR 110.300955107 42KKRR 110.400955114 42KKRR 110.500955121 42KKRR 110.600955022 32KKRR 50.200
model no. EAN code model no. EAN code model no. EAN code
11
Nr. de modéle Code EAN Page187508 17KTA 400967261 17KTA 400 C1KG842667 17KTA 400 E5187607 17KTA 450967278 17KTA 450 C1KG187706 17KTA 500967285 17KTA 500 C1KG917402 17KTA 500 E5187805 17KTA 550967292 17KTA 550 C1KG187904 17KTA 600967308 17KTA 600 C1KG917426 17KTA 600 E5728305 17KTAM 100 E5728404 17KTAM 200 E5728503 17KTAM 300 E5728602 17KTAM 400 E5191956 23KU 5050967315 23KU 5050 C1KG967322 23KU 5050 E5948567 103LFG 40.060948574 103LFG 50.100948581 103LFG 50.150948598 103LFG 50.200948604 103LFG 80.100948611 103LFG 80.150948628 103LFG 80.200948635 103LFG 80.300967605 104LFGAC 40.060948833 104LFGAC 50.100948840 104LFGAC 50.150948857 104LFGAC 50.200948864 104LFGAC 80.100948871 104LFGAC 80.150948888 104LFGAC 80.200948895 104LFGAC 80.300948758 104LFGIC 40.060948765 104LFGIC 50.100948772 104LFGIC 50.150948789 104LFGIC 50.200948796 104LFGIC 80.100948802 104LFGIC 80.150948819 104LFGIC 80.200948826 104LFGIC 80.300948710 103LFGKH 100948727 103LFGKH 150948734 103LFGKH 200948741 103LFGKH 300948703 103LFGKH 60948659 104LFGT 50968343 104LFGT 50/M948666 104LFGT 80968350 104LFGT 80/M948901 105LFGWC 40.060948918 105LFGWC 50.100948925 105LFGWC 50.150948932 105LFGWC 50.200948949 105LFGWC 80.100948956 105LFGWC 80.150948963 105LFGWC 80.200948970 105LFGWC 80.300963034 44MP 110963010 34MP 50963027 39MP 80968398 123PR M860/PA6965489 123PR-MC 10968367 123PR-MC 10 GH968374 123PR-MC 10 GM968381 123PR-MC 10 KE965496 124PR-MC 22966158 125PR-MC 22 BA966219 125PR-MC 22 HBV966172 124PR-MC 22 KE966196 124PR-MC 22 KE/C966202 125PR-MC 22 KE/CP966189 124PR-MC 22 KE/P965502 126PR-MC 30968404 126PR-MC 30 HBV966226 126PR-MC 30 IH966233 126PR-MC 30 KE962730 52SKM 10X30 E4
Nr. de modéle Code EAN Page962730 70SKM 10X30 E4962730 98SKM 10X30 E4962747 52{SKM 10X40 E4}962747 70{SKM 10X40 E4}962747 98{SKM 10X40 E4}957934 52TB957934 70TB967339 23U 5050/1000 C1KG966028 22U 5050/1000 E5L918706 22U 5050/1000 F967346 23U 5050/1100 C1KG918720 22U 5050/1100 F967353 23U 5050/1200 C1KG918744 22U 5050/1200 F967360 23U 5050/1500 C1KG918768 22U 5050/1500 F967377 23U 5050/2000 C1KG918782 22U 5050/2000 F967384 23U 5050/300 C1KG965977 22U 5050/300 E5L918560 22U 5050/300 F859306 22U 5050/3000 F967391 23U 5050/400 C1KG965984 22U 5050/400 E5L918584 22U 5050/400 F967407 23U 5050/500 C1KG965991 22U 5050/500 E5L918607 22U 5050/500 F967414 23U 5050/600 C1KG966004 22U 5050/600 E5L918621 22U 5050/600 F966035 22U 5050/6000 E5L859320 22U 5050/6000 F967421 23U 5050/700 C1KG918645 22U 5050/700 F967438 23U 5050/800 C1KG966011 22U 5050/800 E5L918669 22U 5050/800 F967445 23U 5050/900 C1KG918683 22U 5050/900 F958184 84UL 100.150958191 84UL 100.150/3958207 84UL 100.200958214 84UL 100.200/3958221 84UL 100.300958238 84UL 100.300/3958245 84UL 100.400958252 84UL 100.400/3958269 84UL 100.450958276 84UL 100.450/3958283 84UL 100.500958290 84UL 100.500/3958306 84UL 100.600958313 84UL 100.600/3958344 84UL 100.750958351 84UL 100.750/3958382 84UL 100.900958399 84UL 100.900/3958405 89UL 150.150965168 89UL 150.150/3958412 89UL 150.200965175 89UL 150.200/3958429 89UL 150.300965182 89UL 150.300/3958436 89UL 150.400965199 89UL 150.400/3958443 89UL 150.450965205 89UL 150.450/3958450 89UL 150.500965212 89UL 150.500/3958467 89UL 150.600965229 89UL 150.600/3958481 89UL 150.750965243 89UL 150.750/3958504 89UL 150.900965267 89UL 150.900/3957958 76UL 53.150/3957965 76UL 53.200957972 76UL 53.200/3957989 76UL 53.300957996 76UL 53.300/3
Nr. de modéle Code EAN Page958009 76UL 53.400958016 76UL 53.400/3958023 76UL 53.500958030 76UL 53.500/3958047 76UL 53.600958054 76UL 53.600/3958061 80UL 80.150958078 80UL 80.150/3958085 80UL 80.200958092 80UL 80.200/3958108 80UL 80.300958115 80UL 80.300/3958122 80UL 80.400958139 80UL 80.400/3958146 80UL 80.500958153 80UL 80.500/3958160 80UL 80.600958177 80UL 80.600/3958672 86ULB 100.150958689 86ULB 100.200958696 86ULB 100.300958702 86ULB 100.400958719 86ULB 100.450958726 86ULB 100.500958733 86ULB 100.600958757 86ULB 100.750958771 86ULB 100.900958788 91ULB 150.150958795 91ULB 150.200958801 91ULB 150.300958818 91ULB 150.400958825 91ULB 150.450958832 91ULB 150.500958849 91ULB 150.600958863 91ULB 150.750958887 91ULB 150.900958559 78ULB 53.150958566 78ULB 53.200958573 78ULB 53.300958580 78ULB 53.400958597 78ULB 53.500958603 78ULB 53.600958610 82ULB 80.150958627 82ULB 80.200958634 82ULB 80.300958641 82ULB 80.400958658 82ULB 80.500958665 82ULB 80.600959013 87ULBA 100.150959020 87ULBA 100.200959037 87ULBA 100.300959044 87ULBA 100.400959051 87ULBA 100.450959068 87ULBA 100.500959075 87ULBA 100.600959099 87ULBA 100.750959112 87ULBA 100.900959129 92ULBA 150.150959136 92ULBA 150.200959143 92ULBA 150.300959150 92ULBA 150.400959167 92ULBA 150.450959174 92ULBA 150.500959181 92ULBA 150.600959204 92ULBA 150.750959228 92ULBA 150.900958894 78ULBA 53.150958900 78ULBA 53.200958917 78ULBA 53.300958924 78ULBA 53.400958931 78ULBA 53.500958948 78ULBA 53.600958955 82ULBA 80.150958962 82ULBA 80.200958979 82ULBA 80.300958986 82ULBA 80.400958993 82ULBA 80.500959006 82ULBA 80.600957538 95ULBAD 100.150957545 95ULBAD 100.200957552 95ULBAD 100.300
10
Nr. de modéle Code EAN Page955039 32KKRR 50.300955046 37KKRR 80.200955053 37KKRR 80.300955060 37KKRR 80.400955077 37KKRR 80.500955084 37KKRR 80.600957378 50KKRRD 200957378 68KKRRD 200957385 50KKRRD 300957385 68KKRRD 300957392 50KKRRD 400957392 68KKRRD 400957408 50KKRRD 500957408 68KKRRD 500957415 50KKRRD 600957415 68KKRRD 600954780 31KKSS 50.050954797 31KKSS 50.100954803 31KKSS 50.150954810 31KKSS 50.200954827 31KKSS 50.300954834 36KKSS 80.100954841 36KKSS 80.150954858 36KKSS 80.200954865 36KKSS 80.250954872 36KKSS 80.300957279 49KKSSD 100957279 68KKSSD 100957286 49KKSSD 150957286 68KKSSD 150957293 49KKSSD 200957293 68KKSSD 200957309 49KKSSD 250957309 68KKSSD 250957316 49KKSSD 300957316 68KKSSD 300957262 49KKSSD 50957262 68KKSSD 50954698 41KKST 110.100954704 41KKST 110.200954711 41KKST 110.300954728 41KKST 110.400954735 41KKST 110.500954742 41KKST 110.600954575 31KKST 50.100954582 31KKST 50.150954599 31KKST 50.200954605 31KKST 50.300954612 36KKST 80.100954629 36KKST 80.150954636 36KKST 80.200954643 36KKST 80.250954650 36KKST 80.300954667 36KKST 80.400954674 36KKST 80.500954681 36KKST 80.600957187 49KKSTD 100957187 68KKSTD 100957194 49KKSTD 150957194 68KKSTD 150957200 49KKSTD 200957200 68KKSTD 200957217 49KKSTD 250957217 68KKSTD 250957224 49KKSTD 300957224 68KKSTD 300957231 49KKSTD 400957231 68KKSTD 400957248 49KKSTD 500957248 68KKSTD 500957255 49KKSTD 600957255 68KKSTD 600953042 41KKT 110953073 41KKT 110/M953028 31KKT 50953059 31KKT 50/M953035 36KKT 80953066 36KKT 80/M953776 41KKW 110.100953783 41KKW 110.200953790 41KKW 110.300
Nr. de modéle Code EAN Page953806 41KKW 110.400953813 41KKW 110.500953820 41KKW 110.600953646 32KKW 50.050953653 32KKW 50.100953660 32KKW 50.150953677 32KKW 50.200953684 32KKW 50.300953691 37KKW 80.100953707 37KKW 80.150953714 37KKW 80.200953721 37KKW 80.250953738 37KKW 80.300953745 37KKW 80.400953752 37KKW 80.500953769 37KKW 80.600956548 47KKWD 100956555 47KKWD 150956562 47KKWD 200956579 47KKWD 250956586 47KKWD 300956593 47KKWD 400956531 47KKWD 50956609 47KKWD 500956616 47KKWD 600967612 58KP 40.060952472 58KP 40.060/6952403 58KP 50.100952489 58KP 50.100/6952410 58KP 50.150952496 58KP 50.150/6952427 58KP 50.200952502 58KP 50.200/6952434 62KP 80.100952519 62KP 80.100/6952441 62KP 80.150952526 62KP 80.150/6952458 62KP 80.200952533 62KP 80.200/6952465 62KP 80.300952540 62KP 80.300/6953349 60KPB 50.100/P953356 60KPB 50.150/P953363 60KPB 50.200/P953370 64KPB 80.100/P967643 64KPB 80.150/P953387 64KPB 80.200/P953394 64KPB 80.300/P954216 61KPBA 50.100/P954223 61KPBA 50.150/P954230 61KPBA 50.200/P954247 64KPBA 80.100/P967674 64KPBA 80.150/P954254 64KPBA 80.200/P954261 64KPBA 80.300/P954278 60KPBI 50.100/P954285 60KPBI 50.150/P954292 60KPBI 50.200/P954308 64KPBI 80.100/P967667 64KPBI 80.150/P954315 64KPBI 80.200/P954322 64KPBI 80.300/P953585 60KPC 50.100/P953592 60KPC 50.150/P953608 60KPC 50.200/P953615 63KPC 80.100/P967636 63KPC 80.150/P953622 63KPC 80.200/P953639 63KPC 80.300/P956258 66KPD 100956265 66KPD 150956272 66KPD 200956289 66KPD 300956241 66KPD 60954513 60KPET 50.100/P954520 60KPET 50.150/P954537 60KPET 50.200/P954544 64KPET 80.100/P967650 64KPET 80.150/P954551 64KPET 80.200/P954568 64KPET 80.300/P
Nr. de modéle Code EAN Page955695 59KPGH 40955695 103KPGH 40955701 59KPGH 50955701 103KPGH 50955718 63KPGH 80955718 103KPGH 80955688 59KPIH 40 E5955381 59KPKE 40.060955381 104KPKE 40.060955398 59KPKE 50.100955398 104KPKE 50.100955404 59KPKE 50.150955404 104KPKE 50.150955411 59KPKE 50.200955411 104KPKE 50.200955428 63KPKE 80.100955428 104KPKE 80.100955435 63KPKE 80.150955435 104KPKE 80.150955442 63KPKE 80.200955442 104KPKE 80.200955459 63KPKE 80.300955459 104KPKE 80.300952557 58KPL 40.060952632 58KPL 40.060/6952564 58KPL 50.100952649 58KPL 50.100/6952571 58KPL 50.150952656 58KPL 50.150/6952588 58KPL 50.200952663 58KPL 50.200/6952595 62KPL 80.100952670 62KPL 80.100/6952601 62KPL 80.150952687 62KPL 80.150/6952618 62KPL 80.200952694 62KPL 80.200/6952625 62KPL 80.300952700 62KPL 80.300/6954889 59KPSS 50.100/P954896 59KPSS 50.150/P954902 59KPSS 50.200/P954759 63KPST 80.100/P967629 63KPST 80.150/P954766 63KPST 80.200/P954773 63KPST 80.300/P953127 59KPT 50953141 59KPT 50/M953134 63KPT 80953158 63KPT 80/M955466 70KR 100955541 70KR 100/M955473 70KR 150955558 70KR 150/M955480 70KR 200955565 70KR 200/M955497 70KR 250955572 70KR 250/M955503 70KR 300955589 70KR 300/M955510 70KR 400955596 70KR 400/M955527 70KR 500955602 70KR 500/M955534 70KR 600955619 70KR 600/M186907 17KTA 100967209 17KTA 100 C1KG842605 17KTA 100 E5187003 17KTA 150967216 17KTA 150 C1KG187102 17KTA 200967223 17KTA 200 C1KG842629 17KTA 200 E5187201 17KTA 250967230 17KTA 250 C1KG187300 17KTA 300967247 17KTA 300 C1KG842643 17KTA 300 E5187409 17KTA 350967254 17KTA 350 C1KG
LIST OF ITEMS
model no. EAN code model no. EAN code model no. EAN code
11
Nr. de modéle Code EAN Page187508 17KTA 400967261 17KTA 400 C1KG842667 17KTA 400 E5187607 17KTA 450967278 17KTA 450 C1KG187706 17KTA 500967285 17KTA 500 C1KG917402 17KTA 500 E5187805 17KTA 550967292 17KTA 550 C1KG187904 17KTA 600967308 17KTA 600 C1KG917426 17KTA 600 E5728305 17KTAM 100 E5728404 17KTAM 200 E5728503 17KTAM 300 E5728602 17KTAM 400 E5191956 23KU 5050967315 23KU 5050 C1KG967322 23KU 5050 E5948567 103LFG 40.060948574 103LFG 50.100948581 103LFG 50.150948598 103LFG 50.200948604 103LFG 80.100948611 103LFG 80.150948628 103LFG 80.200948635 103LFG 80.300967605 104LFGAC 40.060948833 104LFGAC 50.100948840 104LFGAC 50.150948857 104LFGAC 50.200948864 104LFGAC 80.100948871 104LFGAC 80.150948888 104LFGAC 80.200948895 104LFGAC 80.300948758 104LFGIC 40.060948765 104LFGIC 50.100948772 104LFGIC 50.150948789 104LFGIC 50.200948796 104LFGIC 80.100948802 104LFGIC 80.150948819 104LFGIC 80.200948826 104LFGIC 80.300948710 103LFGKH 100948727 103LFGKH 150948734 103LFGKH 200948741 103LFGKH 300948703 103LFGKH 60948659 104LFGT 50968343 104LFGT 50/M948666 104LFGT 80968350 104LFGT 80/M948901 105LFGWC 40.060948918 105LFGWC 50.100948925 105LFGWC 50.150948932 105LFGWC 50.200948949 105LFGWC 80.100948956 105LFGWC 80.150948963 105LFGWC 80.200948970 105LFGWC 80.300963034 44MP 110963010 34MP 50963027 39MP 80968398 123PR M860/PA6965489 123PR-MC 10968367 123PR-MC 10 GH968374 123PR-MC 10 GM968381 123PR-MC 10 KE965496 124PR-MC 22966158 125PR-MC 22 BA966219 125PR-MC 22 HBV966172 124PR-MC 22 KE966196 124PR-MC 22 KE/C966202 125PR-MC 22 KE/CP966189 124PR-MC 22 KE/P965502 126PR-MC 30968404 126PR-MC 30 HBV966226 126PR-MC 30 IH966233 126PR-MC 30 KE962730 52SKM 10X30 E4
Nr. de modéle Code EAN Page962730 70SKM 10X30 E4962730 98SKM 10X30 E4962747 52{SKM 10X40 E4}962747 70{SKM 10X40 E4}962747 98{SKM 10X40 E4}957934 52TB957934 70TB967339 23U 5050/1000 C1KG966028 22U 5050/1000 E5L918706 22U 5050/1000 F967346 23U 5050/1100 C1KG918720 22U 5050/1100 F967353 23U 5050/1200 C1KG918744 22U 5050/1200 F967360 23U 5050/1500 C1KG918768 22U 5050/1500 F967377 23U 5050/2000 C1KG918782 22U 5050/2000 F967384 23U 5050/300 C1KG965977 22U 5050/300 E5L918560 22U 5050/300 F859306 22U 5050/3000 F967391 23U 5050/400 C1KG965984 22U 5050/400 E5L918584 22U 5050/400 F967407 23U 5050/500 C1KG965991 22U 5050/500 E5L918607 22U 5050/500 F967414 23U 5050/600 C1KG966004 22U 5050/600 E5L918621 22U 5050/600 F966035 22U 5050/6000 E5L859320 22U 5050/6000 F967421 23U 5050/700 C1KG918645 22U 5050/700 F967438 23U 5050/800 C1KG966011 22U 5050/800 E5L918669 22U 5050/800 F967445 23U 5050/900 C1KG918683 22U 5050/900 F958184 84UL 100.150958191 84UL 100.150/3958207 84UL 100.200958214 84UL 100.200/3958221 84UL 100.300958238 84UL 100.300/3958245 84UL 100.400958252 84UL 100.400/3958269 84UL 100.450958276 84UL 100.450/3958283 84UL 100.500958290 84UL 100.500/3958306 84UL 100.600958313 84UL 100.600/3958344 84UL 100.750958351 84UL 100.750/3958382 84UL 100.900958399 84UL 100.900/3958405 89UL 150.150965168 89UL 150.150/3958412 89UL 150.200965175 89UL 150.200/3958429 89UL 150.300965182 89UL 150.300/3958436 89UL 150.400965199 89UL 150.400/3958443 89UL 150.450965205 89UL 150.450/3958450 89UL 150.500965212 89UL 150.500/3958467 89UL 150.600965229 89UL 150.600/3958481 89UL 150.750965243 89UL 150.750/3958504 89UL 150.900965267 89UL 150.900/3957958 76UL 53.150/3957965 76UL 53.200957972 76UL 53.200/3957989 76UL 53.300957996 76UL 53.300/3
Nr. de modéle Code EAN Page958009 76UL 53.400958016 76UL 53.400/3958023 76UL 53.500958030 76UL 53.500/3958047 76UL 53.600958054 76UL 53.600/3958061 80UL 80.150958078 80UL 80.150/3958085 80UL 80.200958092 80UL 80.200/3958108 80UL 80.300958115 80UL 80.300/3958122 80UL 80.400958139 80UL 80.400/3958146 80UL 80.500958153 80UL 80.500/3958160 80UL 80.600958177 80UL 80.600/3958672 86ULB 100.150958689 86ULB 100.200958696 86ULB 100.300958702 86ULB 100.400958719 86ULB 100.450958726 86ULB 100.500958733 86ULB 100.600958757 86ULB 100.750958771 86ULB 100.900958788 91ULB 150.150958795 91ULB 150.200958801 91ULB 150.300958818 91ULB 150.400958825 91ULB 150.450958832 91ULB 150.500958849 91ULB 150.600958863 91ULB 150.750958887 91ULB 150.900958559 78ULB 53.150958566 78ULB 53.200958573 78ULB 53.300958580 78ULB 53.400958597 78ULB 53.500958603 78ULB 53.600958610 82ULB 80.150958627 82ULB 80.200958634 82ULB 80.300958641 82ULB 80.400958658 82ULB 80.500958665 82ULB 80.600959013 87ULBA 100.150959020 87ULBA 100.200959037 87ULBA 100.300959044 87ULBA 100.400959051 87ULBA 100.450959068 87ULBA 100.500959075 87ULBA 100.600959099 87ULBA 100.750959112 87ULBA 100.900959129 92ULBA 150.150959136 92ULBA 150.200959143 92ULBA 150.300959150 92ULBA 150.400959167 92ULBA 150.450959174 92ULBA 150.500959181 92ULBA 150.600959204 92ULBA 150.750959228 92ULBA 150.900958894 78ULBA 53.150958900 78ULBA 53.200958917 78ULBA 53.300958924 78ULBA 53.400958931 78ULBA 53.500958948 78ULBA 53.600958955 82ULBA 80.150958962 82ULBA 80.200958979 82ULBA 80.300958986 82ULBA 80.400958993 82ULBA 80.500959006 82ULBA 80.600957538 95ULBAD 100.150957545 95ULBAD 100.200957552 95ULBAD 100.300
model no. EAN code model no. EAN code model no. EAN code
11
Nr. de modéle Code EAN Page187508 17KTA 400967261 17KTA 400 C1KG842667 17KTA 400 E5187607 17KTA 450967278 17KTA 450 C1KG187706 17KTA 500967285 17KTA 500 C1KG917402 17KTA 500 E5187805 17KTA 550967292 17KTA 550 C1KG187904 17KTA 600967308 17KTA 600 C1KG917426 17KTA 600 E5728305 17KTAM 100 E5728404 17KTAM 200 E5728503 17KTAM 300 E5728602 17KTAM 400 E5191956 23KU 5050967315 23KU 5050 C1KG967322 23KU 5050 E5948567 103LFG 40.060948574 103LFG 50.100948581 103LFG 50.150948598 103LFG 50.200948604 103LFG 80.100948611 103LFG 80.150948628 103LFG 80.200948635 103LFG 80.300967605 104LFGAC 40.060948833 104LFGAC 50.100948840 104LFGAC 50.150948857 104LFGAC 50.200948864 104LFGAC 80.100948871 104LFGAC 80.150948888 104LFGAC 80.200948895 104LFGAC 80.300948758 104LFGIC 40.060948765 104LFGIC 50.100948772 104LFGIC 50.150948789 104LFGIC 50.200948796 104LFGIC 80.100948802 104LFGIC 80.150948819 104LFGIC 80.200948826 104LFGIC 80.300948710 103LFGKH 100948727 103LFGKH 150948734 103LFGKH 200948741 103LFGKH 300948703 103LFGKH 60948659 104LFGT 50968343 104LFGT 50/M948666 104LFGT 80968350 104LFGT 80/M948901 105LFGWC 40.060948918 105LFGWC 50.100948925 105LFGWC 50.150948932 105LFGWC 50.200948949 105LFGWC 80.100948956 105LFGWC 80.150948963 105LFGWC 80.200948970 105LFGWC 80.300963034 44MP 110963010 34MP 50963027 39MP 80968398 123PR M860/PA6965489 123PR-MC 10968367 123PR-MC 10 GH968374 123PR-MC 10 GM968381 123PR-MC 10 KE965496 124PR-MC 22966158 125PR-MC 22 BA966219 125PR-MC 22 HBV966172 124PR-MC 22 KE966196 124PR-MC 22 KE/C966202 125PR-MC 22 KE/CP966189 124PR-MC 22 KE/P965502 126PR-MC 30968404 126PR-MC 30 HBV966226 126PR-MC 30 IH966233 126PR-MC 30 KE962730 52SKM 10X30 E4
Nr. de modéle Code EAN Page962730 70SKM 10X30 E4962730 98SKM 10X30 E4962747 52{SKM 10X40 E4}962747 70{SKM 10X40 E4}962747 98{SKM 10X40 E4}957934 52TB957934 70TB967339 23U 5050/1000 C1KG966028 22U 5050/1000 E5L918706 22U 5050/1000 F967346 23U 5050/1100 C1KG918720 22U 5050/1100 F967353 23U 5050/1200 C1KG918744 22U 5050/1200 F967360 23U 5050/1500 C1KG918768 22U 5050/1500 F967377 23U 5050/2000 C1KG918782 22U 5050/2000 F967384 23U 5050/300 C1KG965977 22U 5050/300 E5L918560 22U 5050/300 F859306 22U 5050/3000 F967391 23U 5050/400 C1KG965984 22U 5050/400 E5L918584 22U 5050/400 F967407 23U 5050/500 C1KG965991 22U 5050/500 E5L918607 22U 5050/500 F967414 23U 5050/600 C1KG966004 22U 5050/600 E5L918621 22U 5050/600 F966035 22U 5050/6000 E5L859320 22U 5050/6000 F967421 23U 5050/700 C1KG918645 22U 5050/700 F967438 23U 5050/800 C1KG966011 22U 5050/800 E5L918669 22U 5050/800 F967445 23U 5050/900 C1KG918683 22U 5050/900 F958184 84UL 100.150958191 84UL 100.150/3958207 84UL 100.200958214 84UL 100.200/3958221 84UL 100.300958238 84UL 100.300/3958245 84UL 100.400958252 84UL 100.400/3958269 84UL 100.450958276 84UL 100.450/3958283 84UL 100.500958290 84UL 100.500/3958306 84UL 100.600958313 84UL 100.600/3958344 84UL 100.750958351 84UL 100.750/3958382 84UL 100.900958399 84UL 100.900/3958405 89UL 150.150965168 89UL 150.150/3958412 89UL 150.200965175 89UL 150.200/3958429 89UL 150.300965182 89UL 150.300/3958436 89UL 150.400965199 89UL 150.400/3958443 89UL 150.450965205 89UL 150.450/3958450 89UL 150.500965212 89UL 150.500/3958467 89UL 150.600965229 89UL 150.600/3958481 89UL 150.750965243 89UL 150.750/3958504 89UL 150.900965267 89UL 150.900/3957958 76UL 53.150/3957965 76UL 53.200957972 76UL 53.200/3957989 76UL 53.300957996 76UL 53.300/3
Nr. de modéle Code EAN Page958009 76UL 53.400958016 76UL 53.400/3958023 76UL 53.500958030 76UL 53.500/3958047 76UL 53.600958054 76UL 53.600/3958061 80UL 80.150958078 80UL 80.150/3958085 80UL 80.200958092 80UL 80.200/3958108 80UL 80.300958115 80UL 80.300/3958122 80UL 80.400958139 80UL 80.400/3958146 80UL 80.500958153 80UL 80.500/3958160 80UL 80.600958177 80UL 80.600/3958672 86ULB 100.150958689 86ULB 100.200958696 86ULB 100.300958702 86ULB 100.400958719 86ULB 100.450958726 86ULB 100.500958733 86ULB 100.600958757 86ULB 100.750958771 86ULB 100.900958788 91ULB 150.150958795 91ULB 150.200958801 91ULB 150.300958818 91ULB 150.400958825 91ULB 150.450958832 91ULB 150.500958849 91ULB 150.600958863 91ULB 150.750958887 91ULB 150.900958559 78ULB 53.150958566 78ULB 53.200958573 78ULB 53.300958580 78ULB 53.400958597 78ULB 53.500958603 78ULB 53.600958610 82ULB 80.150958627 82ULB 80.200958634 82ULB 80.300958641 82ULB 80.400958658 82ULB 80.500958665 82ULB 80.600959013 87ULBA 100.150959020 87ULBA 100.200959037 87ULBA 100.300959044 87ULBA 100.400959051 87ULBA 100.450959068 87ULBA 100.500959075 87ULBA 100.600959099 87ULBA 100.750959112 87ULBA 100.900959129 92ULBA 150.150959136 92ULBA 150.200959143 92ULBA 150.300959150 92ULBA 150.400959167 92ULBA 150.450959174 92ULBA 150.500959181 92ULBA 150.600959204 92ULBA 150.750959228 92ULBA 150.900958894 78ULBA 53.150958900 78ULBA 53.200958917 78ULBA 53.300958924 78ULBA 53.400958931 78ULBA 53.500958948 78ULBA 53.600958955 82ULBA 80.150958962 82ULBA 80.200958979 82ULBA 80.300958986 82ULBA 80.400958993 82ULBA 80.500959006 82ULBA 80.600957538 95ULBAD 100.150957545 95ULBAD 100.200957552 95ULBAD 100.300
12
Nr. de modéle Code EAN Page957569 95ULBAD 100.400957576 95ULBAD 100.450957583 95ULBAD 100.500957590 95ULBAD 100.600957613 95ULBAD 100.750957637 95ULBAD 100.900059089 95ULBAD 150.150059096 95ULBAD 150.200059119 95ULBAD 150.300059126 95ULBAD 150.400059133 95ULBAD 150.450059140 95ULBAD 150.500059157 95ULBAD 150.600059164 95ULBAD 150.750059171 95ULBAD 150.900059188 94ULBAD 53.150059195 94ULBAD 53.200059218 94ULBAD 53.300059225 94ULBAD 53.400059232 94ULBAD 53.500059249 94ULBAD 53.600059256 95ULBAD 80.150059263 95ULBAD 80.200059270 95ULBAD 80.300059287 95ULBAD 80.400059294 95ULBAD 80.500059317 95ULBAD 80.600957422 94ULBD 150957439 94ULBD 200957446 94ULBD 300957453 94ULBD 400957460 94ULBD 450957477 94ULBD 500957484 94ULBD 600957507 94ULBD 750957521 94ULBD 900960170 85ULGH 100960187 90ULGH 150960156 76ULGH 53960163 80ULGH 80960255 87ULGV 100960262 92ULGV 150960231 79ULGV 53960248 83ULGV 80960217 85ULIH 100 E4960224 90ULIH 150 E4960194 77{ULIH 53 E4}960200 81ULIH 80 E4960293 88ULIV 100 E4960309 93ULIV 150 E4960279 79ULIV 53 E4960286 83ULIV 80 E4965526 84ULKE 100.150965533 84ULKE 100.200965540 84ULKE 100.300965557 84ULKE 100.400965564 84ULKE 100.450965571 84ULKE 100.500965588 84ULKE 100.600965595 84ULKE 100.700965601 84ULKE 100.750965618 84ULKE 100.800965625 84ULKE 100.900965632 89ULKE 150.150965649 89ULKE 150.200
Nr. de modéle Code EAN Page965656 89ULKE 150.300965663 89ULKE 150.400965670 89ULKE 150.450965687 89ULKE 150.500965694 89ULKE 150.600965717 89ULKE 150.750965731 89ULKE 150.900965748 76ULKE 53.150965755 76ULKE 53.200965762 76ULKE 53.300965779 76ULKE 53.400965786 76ULKE 53.500965793 76ULKE 53.600965809 80ULKE 80.150965816 80ULKE 80.200965823 80ULKE 80.300965830 80ULKE 80.400965847 80ULKE 80.500965854 80ULKE 80.600960316 98ULKG960323 98ULKH E4960330 96ULKV E4960347 99ULP 100960019 87ULRU 100.100960026 87ULRU 100.150960033 87ULRU 100.200960040 87ULRU 100.300960057 87ULRU 100.400960064 87ULRU 100.500960071 87ULRU 100.600960088 92ULRU 150.100960095 92ULRU 150.150960101 92ULRU 150.200960118 92ULRU 150.300960125 92ULRU 150.400960132 92ULRU 150.500960149 92ULRU 150.600959914 78ULRU 53.100959921 78ULRU 53.150959938 78ULRU 53.200959945 78ULRU 53.300959952 78ULRU 53.400959969 82ULRU 80.100959976 82ULRU 80.150959983 82ULRU 80.200959990 82ULRU 80.300960002 82ULRU 80.400959358 85ULTE 100.150959365 85ULTE 100.200959372 85ULTE 100.300959389 85ULTE 100.400959396 85ULTE 100.450959402 85ULTE 100.500959419 85ULTE 100.600959433 85ULTE 100.750959457 85ULTE 100.900959464 90ULTE 150.150959471 90ULTE 150.200959488 90ULTE 150.300959495 90ULTE 150.400959501 90ULTE 150.450959518 90ULTE 150.500959525 90ULTE 150.600959549 90ULTE 150.750959563 90ULTE 150.900
Nr. de modéle Code EAN Page959235 77ULTE 53.150959242 77ULTE 53.200959259 77ULTE 53.300959266 77ULTE 53.400959273 77ULTE 53.500959280 77ULTE 53.600959297 81ULTE 80.150959303 81ULTE 80.200959310 81ULTE 80.300959327 81ULTE 80.400959334 81ULTE 80.500959341 81ULTE 80.600957644 96ULTED 150957651 96ULTED 200957668 96ULTED 300957675 96ULTED 400957682 96ULTED 450957699 96ULTED 500957705 96ULTED 600957729 96ULTED 750957743 96ULTED 900958535 85ULTL 100958542 90ULTL 150958511 77ULTL 53958528 81ULTL 80959693 86ULX 100.150959709 86ULX 100.200959716 86ULX 100.300959723 86ULX 100.400959730 86ULX 100.450959747 86ULX 100.500959754 86ULX 100.600959778 86ULX 100.750959792 86ULX 100.900959808 91ULX 150.150959815 91ULX 150.200959822 91ULX 150.300959839 91ULX 150.400959846 91ULX 150.450959853 91ULX 150.500959860 91ULX 150.600959884 91ULX 150.750959907 91ULX 150.900959570 77ULX 53.150959587 77ULX 53.200959594 77ULX 53.300959600 77ULX 53.400959617 77ULX 53.500959624 77ULX 53.600959631 81ULX 80.150959648 81ULX 80.200959655 81ULX 80.300959662 81ULX 80.400959679 81ULX 80.500959686 81ULX 80.600957750 96ULXD 150957767 96ULXD 200957774 96ULXD 300957781 96ULXD 400957798 96ULXD 450957804 96ULXD 500957811 96ULXD 600957835 96ULXD 750957859 96ULXD 900728909 99WWU 150/8 E5
LIST OF ITEMS
model no. EAN code model no. EAN code model no. EAN code
51
Fixation de couvercle
Utilisable pour : Couvercles de chemins de câbles KKD... et KPD...Couvercle des pièces de forme KKCD..., KKBD..., KKWD..., KKBAD..., KKBID...,KKETD..., KKSTD..., KKSSD..., KKRLD... und KKRRD..
DF M
K01
Réf. Art. Coli-sage mini.
50 p.
CodeEAN
957927
Poids100uni.
pc.
kg
0,2
Pour la fixation du couvercle, il est necessaire de percer un trou de diamètre 8,2 mm. Dans desconditions difficiles, comme par exemple en cas de vents forts, il faudra augmenter le nombre defixations.
Fixation de couvercle
Utilisable pour : Couvercles de chemins de câbles KKD... et KPD...Couvercle des pièces de forme KKCD..., KKBD..., KKWD..., KKBAD..., KKBID...,KKETD..., KKSTD..., KKSSD..., KKRLD... und KKRRD..
DFUB 5.5X19 E4
N E4
Réf. Art. Coli-sage mini.
CodeEAN
062065
Poids100uni.
kg
0,64
Pour la fixation du couvercle, il est necessaire de percer un trou de diamètre 8,2 mm. Dans desconditions difficiles, comme par exemple en cas de vents forts, il faudra augmenter le nombre defixations.
Clip de fixation de couvercleinox
pour la fixation des couvercles de chemins de câbles et des pièces de forme
Utilisable pour : Couvercles de chemins de câbles KKD...
DF 1060 E4
E4
Réf. Art. Coli-sage mini.
50 p.
CodeEAN
957910
Poids100uni.
pc.
kg
1,1
Lors de la fixation, dans des conditions normales, il faut prendre soin de monter un clip par m enquiconce. Dans des conditions difficiles, comme par exemple en cas de vents forts, il faudraaugmenter le nombre de clips.
NOTES
13
Support System
Ceiling bracket and wall bracket
Brackets
Profi les
Mounting plates
TKTKTKTK14
CABLE TRAY SYSTEM GFK
Compatible with our different ranges of cable trays, our supporting systems are available in
several fi nishes and different support structures. A range of support structures ranging from hot-dip
galvanized steel and epoxy, through the stainless steel, loaded polyester reinforced fi berglass.
Dimensions and perforations supports are suitable for EBO Systems cables trays.
The load capacities are variable according to the type of installation (ceiling, wall ...).
Profi les
Mounting plates
15
Overview brackets and hangers
Hangers and wall supports - average load KTAM 17
Hangers and wall supports, standard KTA 17
GRP brackets, pultruded FPAP 18
GRP brackets, pressed FPAM 18
GRP brackets, pultruded, Z Profi l FPCO 19
GRP support, pultruded FPPS 19
Hangers, U profi le HU 5050 20/21
Hangers-profi les HDS 21/22
Profi l U 5050 22/23
Anchor fi xing plate KU 5050 23
GRP hangers, U profi l FPES 24
GRP hangers, pultruded, Profi l C FPDS 24
STAINLESS STEEL Fixing system SS anchor bolt FPBGV 24
Track C-Profi l, opening of 15 mm, perforated FPAR 25
Protective cover KA 18
Protective cover K 5050 21
SYSTEM
ACCESSORIES
The classifi cation of brackets and hangers into categories like light, medium and heavy is only an indication for their typical usage. For engineering purposes exact calculations of overall loads considering the weight of the cable, the weight of the tray and the support span are mandatory. In the event that the support structures and loads of cables are uniformly distributed, the supporting capacity of the bracket must be calculated as follows: load F = (cables weight + weight of the various components of the support installation) x support distance
Load ratings shown in this catalog are valid only for proper anchorage to the building structure. Please refer to the general information section and consult site management or structural enginee-ring for details about the building structure and local regulations.
!16
SUPPORT SYSTEM
17
Hanger and wall bracketmiddle range
Warning: different properties for various lengths
for a wall mounting or a ceiling mounting
KTAM 100 E5
60 110 1,2 2 FLM 6x12 E5KTAM 200 E5 80 210 1,2 2 FLM 6x12 E5KTAM 300 E5 85 310 1,2 2 FLM 6x12 E5KTAM 400 E5 115 410 1,2 2 FLM 6x12 E5
E5
E5E5E5
Item ref. Height LengthL
adj. at L/2
Accessories/bolts
includedmm mm kN
Min. pack.
20 p.20 p.20 p.20 p.
EANcode
728305728404728503728602
Weight 100 units
pc.
16,5130,6144,3373,59
The load capacities are only valid if the main supporting part is sufficiently and correctly fixed,particularly the ceiling supports.
Ceiling support and wall bracketstandard range
for a wall mounting and for a ceiliing mounting
Mounting accessories required for cable ladder UL : ULKG, M10x30 V4A (to be ordered separatly )
KTA 100
45 40 110 2,5 2 FLM 6x12KTA 150 45 40 160 2,5 2 FLM 6x12KTA 200 55 40 210 2,5 2 FLM 6x12KTA 250 55 40 260 2,5 2 FLM 6x12KTA 300 65 50 310 2,5 2 FLM 6x12KTA 350 65 50 360 2,5 2 FLM 6x12KTA 400 75 50 410 2,5 2 FLM 6x12KTA 450 75 50 460 2,5 2 FLM 6x12KTA 500 90 50 510 2,5 2 FLM 6x12KTA 550 90 50 560 2,5 2 FLM 6x12KTA 600 90 50 610 2,5 2 FLM 6x12KTA 100 E5
45 40 110 2,5 2 FLM 6x12 E5KTA 200 E5 55 40 210 2,5 2 FLM 6x12 E5KTA 300 E5 65 50 310 2,5 2 FLM 6x12 E5KTA 400 E5 90 50 410 2,5 2 FLM 6x12 E5KTA 500 E5 110 50 510 2,5 2 FLM 6x12 E5KTA 600 E5 110 50 610 2,5 2 FLM 6x12 E5
F
FFFFFFFFFF
E5
E5E5E5E5E5
Item ref. Height WidthB
LengthL
adj. at L/2
Accessories/bolts
includedmm mm mm kN
Min. pack.
20 p.20 p.20 p.20 p.20 p.20 p.20 p.10 p.10 p.10 p.10 p.20 p.20 p.20 p.20 p.20 p.20 p.
EANcode
186907187003187102187201187300187409187508187607187706187805187904842605842629842643842667917402917426
Weight 100 units
pc. /
13,6016,9025,2029,8055,8062,7075,2083,80
106,70129,20122,8014,8025,9255,6980,00
120,00135,00
The load capacities are only valid if the main supporting part is sufficiently and correctly fixed,particularly the ceiling supports.
Oblong holes dimensions LL 7x40 mm in the KTA 100-600 seriesOblong holes dimensions LL 7x15 mm in the KTA 150-550 series (intermediate sizes) and in thealuminum finish KTA 100-600
Ceiling support and wall bracketepoxy, standard
for a wall mounting on supporting rail FPAR and on ceiling support FPES / FPDS
Mounting accessories required for cable ladder UL: ULKG, M6x30 V4A (to be ordered separatly )Mounting accessories required for cable ladder UL: ULKG, M10x30 V4A (to be ordered separatly )
KTA 100 C1KG
7032 45 40 110 2,5 2 FLM 6x12 E5KTA 150 C1KG 7032 45 40 160 2,5 2 FLM 6x12 E5KTA 200 C1KG 7032 55 40 210 2,5 2 FLM 6x12 E5KTA 250 C1KG 7032 55 40 260 2,5 2 FLM 6x12 E5KTA 300 C1KG 7032 65 50 310 2,5 2 FLM 6x12 E5KTA 350 C1KG 7032 65 50 360 2,5 2 FLM 6x12 E5KTA 400 C1KG 7032 75 50 410 2,5 2 FLM 6x12 E5KTA 450 C1KG 7032 75 50 460 2,5 2 FLM 6x12 E5KTA 500 C1KG 7032 90 50 510 2,5 2 FLM 6x12 E5KTA 550 C1KG 7032 90 50 560 2,5 2 FLM 6x12 E5KTA 600 C1KG 7032 90 50 610 2,5 2 FLM 6x12 E5
C1
C1C1C1C1C1C1C1C1C1C1
Item ref. RAL colour
Height WidthB
LengthL
adj. at L/2
Accessories/bolts
includedmm mm mm kN
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
967209967216967223967230967247967254967261967278967285967292967308
Weight 100 units
pc
13,116,424,428,853,960,772,881,1
103,3125,0118,8
The load capacities are only valid if the main supporting part is sufficiently and correctly fixed,particularly the ceiling supports.
Oblong holes dimensions LL 7x40 mm in the KTA 100-600 seriesOblong holes dimensions LL 7x15 mm in the KTA 150-550 series (intermediate sizes) and in thealuminum finish KTA 100-600
18
SUPPORT SYSTEM
Protective end cap
The end caps must prescripted in areas where the risk of hazard is important!
to protect the profile ends
KA 100-600
yellowK10
Item ref. Colour Min. pack.
10 p.
EANcode
347056
Weight 100 units
1,4
GRP bracketpultruded
for a wall mounting and for a ceiliing mounting
Used for: Hanger FPES… and FPDS…
Fixing accessories for cables trays ( to be ordered separately ) : for cables trays K² and KP : M6x20 V4A
FPAP 100/AC
7032 110 1,25FPAP 150/AC 7032 160 1,25FPAP 200/AC 7032 210 1,25FPAP 250/AC 7032 260 1,25FPAP 300/AC 7032 310 1,25
K23
K23K23K23K23
Item ref. RAL colour
LengthL
adj. at L/2
mm kN
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
955725955732955749955756955763
Weight 100 units
pc. pc/
47,054,558,565,072,2
The load capacities are only valid if the main supporting part is sufficiently and correctly fixed,particularly the ceiling supports.
GRP bracketpultruded
for a wall mounting and for a ceiliing mounting
Used for: Hanger FPES… and FPDS…
FPAP 400/AC
7032 410 1,25FPAP 500/AC 7032 510 1,25FPAP 600/AC 7032 610 1,25
K23
K23K23
Item ref. RAL colour
LengthL
adj. at L/2
mm kN
Min. pack.
1 p.1 p.1 p.
EANcode
955770955787955794
Weight 100 units
pc
161,5174,5186,0
The load capacities are only valid if the main supporting part is sufficiently and correctly fixed,particularly the ceiling supports.
GRP bracketpressed
for a wall mounting and for a ceiliing mounting
Used for: Hanger FPES… and FPDS…
FPAM 100
7032 50 55 120 1,25FPAM 150 7032 60 55 170 1,25FPAM 200 7032 70 55 220 1,25FPAM 300 7032 90 55 320 1,25
K23
K23K23K23
Item ref. RAL colour
Height WidthB
LengthL
adj. at L/2
mm mm mm kN
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
955848955855955862955879
Weight 100 units
pc.
17183650
The load capacities are only valid if the main supporting part is sufficiently and correctly fixed,particularly the ceiling supports.
19
GRP bracketpultruded, Z-profile
for the horizontal mounting of cable trays
Used for: Only for the cable trays KK… and KP…
Mounting accessories required for cable tray K2 and KP : M6x20 V4A ( to be ordered separatly )
FPCO 100/AC
7032 100FPCO 150/AC 7032 150FPCO 200/AC 7032 200FPCO 300/AC 7032 300
K23
K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
963102963119963126963133
Weight 100 units
pc
556877
100
GRP supportpultruded, Z-profile
The support is universal
for the horizontal mounting of cable trays
Used for: Only for the cable trays KK… and KP… and UL…
Mounting accessories required for cable tray K2 and KP : M6x20 V4A ( to be ordered separatly )
FPPS
7032K23
Item ref. RAL colour
Min. pack.
1 p.
EANcode
963140
Weight 100 units
pc
0
20
SUPPORT SYSTEM
Ceiling supportProfile U
Load F in kN
Def
lect
ion
f in
mm
In case of symetrical loads, the deflection is not significant.
Total length = U profile length, included fixing plate.HU 5050/200, has limited space for equipment in cable trays (bracket length & height)Used for: Rail FPAR and wall mounted bracket FPAP
Rail and wall mounted bracket KTA...
Load diagram : deflection of the hanger in case of one-sided charges
HU 5050/200
205HU 5050/250 255HU 5050/300 305HU 5050/400 405HU 5050/500 505HU 5050/600 605HU 5050/700 705HU 5050/800 805HU 5050/900 905HU 5050/1000 1005HU 5050/1100 1105HU 5050/1200 1205HU 5050/1500 1505HU 5050/2000 2005HU 5050/200 E5
205HU 5050/300 E5 305HU 5050/400 E5 405HU 5050/500 E5 505HU 5050/600 E5 605HU 5050/800 E5 805HU 5050/1000 E5 1005
F
FFFFFFFFFFFFF
E5
E5E5E5E5E5E5
Item ref. Total length L
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
858705858729858743858767858781858804858828858842858866858880858903858927858941858965945757945702945764945771945788965953965960
Weight 100 units
pc. pc/
93,08105,23117,38141,68165,97190,27214,57238,87263,17287,46311,76336,06408,95530,4486,02
108,48130,92153,38175,83220,74265,65
The load data are only valid in case of a sufficiently strong fixing of the supporting part. The share ofloads in the building must be defined with the contractor. You must follow the guidelines anddefinitions in force.
In order to avoid the deformation of ceiling support during the mounting of brackets, it is necessaryfor mechanical reason, to take into account of the thickness of the ceiling support when screwing thehexagonal bolts. for static reasons and to facilitate the mounting of end caps, the bracket must be mounted at x=50 mmabove the ceiling support end.To prevent the deformation of the ceiling support profile when installing the brackets, it isrecommended to use hexagonal head bolts for mechanical reasons. Serie of oblong holes (13x40 mm) on 3 profile sides.
21
Hangerepoxy, U-profile
Load F in kN
Def
lect
ion
f in
mm
In case of symetrical loads, the deflection is not significant.
Total length = U profile length, included fixing plate.HU 5050/200, has limited space for equipment in cable trays (bracket length & height)Used for: Hangers FPES / FPDS and wall bracket FPAP
Rail FPAR and wall mounted bracket FPAP
Load diagram : deflection of the hanger in case of one-sided charges
HU 5050/200 C1KG
7032 205HU 5050/250 C1KG 7032 255HU 5050/300 C1KG 7032 305HU 5050/400 C1KG 7032 405HU 5050/500 C1KG 7032 505HU 5050/600 C1KG 7032 605HU 5050/700 C1KG 7032 705HU 5050/800 C1KG 7032 805HU 5050/900 C1KG 7032 905HU 5050/1000 C1KG 7032 1005HU 5050/1100 C1KG 7032 1105HU 5050/1200 C1KG 7032 1205HU 5050/1500 C1KG 7032 1505HU 5050/2000 C1KG 7032 2005
C1
C1C1C1C1C1C1C1C1C1C1C1C1C1
Item ref. RAL colour
Total length L
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
967100967124967131967148967155967162967179967186967193967063967070967087967094967117
Weight 100 units
pc
88,099,5
111,0133,9156,9179,9202,9225,8248,8271,8294,8317,7386,6501,5
Protective end cap
The end caps must prescripted in areas where the risk of hazard is important!
to protect the profile ends
Used for: Profile U 5050/… and hanger HU 5050/…
K 5050
yellowK10
Item ref. Colour Min. pack.
10 p.
EANcode
347025
Weight 100 units
pc.
3
To facilitate the assembly of end caps, a minimum space of 50 mm is required between the bracketbottom and the ceiling support end.
Ceiling support profile
Used for: Profile U 5050/… and hanger HU 5050/…
HDS 50.50 F
1 SKM 10x80 F, 2 UGM 10HDS 50.50 E5
1 SKM 10x90 E4, 2 UGM 10F
E5
Item ref. Accessories/bolts
included
Min. pack.
50 p.50 p.
EANcode
931705962266
Weight 100 units
pc. pc/
7,56,8
In order to avoid the deformation of ceiling support during the mounting of brackets, it is necessaryfor mechanical reason, to take into account of the thickness of the ceiling support when screwing thehexagonal bolts. To prevent the deformation of the ceiling support profile when installing the brackets, it isrecommended to use hexagonal head bolts for mechanical reasons.
21
Pendardepoxy, Profil U
Charge F en KN
Déf
lexi
on f
en m
m
Dans le cas de charges à peu près symétriques, la déflexion est à peine mesurable.
Longueur totale = la longueur du profil U, plaque de fixation compriseHU 5050/200, dispose d'un espace restreint pour l'equipement en chemins de câbles (lalongueur des pendards - la hauteur des consoles)Utilisable pour : Pendard FPES / FPDS et console murale FPAP
Rail FPAR et console murale FPAP
Diagramme des charges : flexion du pendard dans le cas d'une charge unilatérale.
HU 5050/200 C1KG
7032 205HU 5050/250 C1KG 7032 255HU 5050/300 C1KG 7032 305HU 5050/400 C1KG 7032 405HU 5050/500 C1KG 7032 505HU 5050/600 C1KG 7032 605HU 5050/700 C1KG 7032 705HU 5050/800 C1KG 7032 805HU 5050/900 C1KG 7032 905HU 5050/1000 C1KG 7032 1005HU 5050/1100 C1KG 7032 1105HU 5050/1200 C1KG 7032 1205HU 5050/1500 C1KG 7032 1505HU 5050/2000 C1KG 7032 2005
C1
C1C1C1C1C1C1C1C1C1C1C1C1C1
Réf. Art. Cou-leurRAL
Longueur totale L
mm
Coli-sage mini.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
CodeEAN
967100967124967131967148967155967162967179967186967193967063967070967087967094967117
Poids100uni.
pc
kg
88,099,5
111,0133,9156,9179,9202,9225,8248,8271,8294,8317,7386,6501,5
Embout de protection
Les embouts de protection sont à prescrire dans les zones où le risque d'accident estimportant !
pour la protection des extrémités de profils
Utilisable pour : Profil U 5050/... et pendard HU 5050/...
K 5050
jauneK10
Réf. Art. Couleur Coli-sage mini.
10 p.
CodeEAN
347025
Poids100uni.
pc.
kg
3
Pour faciliter le montage des embouts de protection, un écart d'au moins 50 mm est à respecter entrela partie inférieure de la console et le bout du pendard.
Profil du pendard
Utilisable pour : Profil U 5050/... et pendard HU 5050/...
HDS 50.50 F
1 SKM 10x80 F, 2 UGM 10HDS 50.50 E5
1 SKM 10x90 E4, 2 UGM 10F
E5
Réf. Art. Accessoires/Boulonnerie
incluse
Coli-sage mini.
50 p.50 p.
CodeEAN
931705962266
Poids100uni.
pc. pc/
kg
7,56,8
Dans le but d'éviter la déformation des pendards au moment du montage des consoles, il estnécessaire pour des raisons statiques, de tenir compte de l'épaisseur du profil du pendard au momentdu serrage avec les boulons à têtes hexagonales.Pour empêcher la déformation du profil du pendard lors du montage des consoles, il faut utiliser desboulons à tête hexagonale pour des raisons mécaniques.
22
SUPPORT SYSTEM
Ceiling support profileepoxy
Used for: Profile U 5050/... C1KG and hanger HU 5050/… C1KG
HDS 50.50 C1KG
7032 1 SKM 10x90 E4, 2 UGM 10C1
Item ref. RAL colour
Accessories/bolts
included
Min. pack.
10 p.
EANcode
967056
Weight 100 units
pc
7,5
To prevent the deformation of the ceiling support profile when installing the brackets, it isrecommended to use hexagonal head bolts for mechanical reasons.
Profile U 5050
for the manufacturing of ceiling supports and supporting systems made of different elements
U 5050/300 F
300U 5050/400 F 400U 5050/500 F 500U 5050/600 F 600U 5050/700 F 700U 5050/800 F 800U 5050/900 F 900U 5050/1000 F 1000U 5050/1100 F 1100U 5050/1200 F 1200U 5050/1500 F 1500U 5050/2000 F 2000U 5050/3000 F 3000U 5050/6000 F 6000U 5050/300 E5L
300U 5050/400 E5L 400U 5050/500 E5L 500U 5050/600 E5L 600U 5050/800 E5L 800U 5050/1000 E5L 1000U 5050/6000 E5L 6000
F
FFFFFFFFFFFFF
E5
E5E5E5E5E5E5
Item ref. LengthL
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.2 m3 m6 m1 p.1 p.1 p.1 p.1 p.1 p.6 m
EANcode
918560918584918607918621918645918669918683918706918720918744918768918782859306859320965977965984965991966004966011966028966035
Weight 100 units
pc. pc/ m/
72,9097,20
121,50145,79170,09194,38218,68242,98267,28291,58364,47242,98242,98242,9867,3789,82
112,28134,73179,64224,55224,55
Serie of oblong holes (13x40 mm) on 3 profile sides
23
Profile U 5050epoxy
for the manufacturing of ceiling supports and supporting systems made of different elements
U 5050/300 C1KG
7032 300U 5050/400 C1KG 7032 400U 5050/500 C1KG 7032 500U 5050/600 C1KG 7032 600U 5050/700 C1KG 7032 700U 5050/800 C1KG 7032 800U 5050/900 C1KG 7032 900U 5050/1000 C1KG 7032 1000U 5050/1100 C1KG 7032 1100U 5050/1200 C1KG 7032 1200U 5050/1500 C1KG 7032 1500U 5050/2000 C1KG 7032 2000
C1
C1C1C1C1C1C1C1C1C1C1C1
Item ref. RAL colour
LengthL
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 m
EANcode
967384967391967407967414967421967438967445967339967346967353967360967377
Weight 100 units
pc
72,0096,00
120,00144,00168,00192,00216,00128,33141,17154,00359,00229,73
Serie of oblong holes (13x40 mm) on 3 profile sides
Anchor fixing plate included bolts
for the mounting on straight ceilings
Used for: Profile U 5050/…
KU 5050
105 5 2 FLM 10x25 FKU 5050 E5
105 5 2 FLM 10x25 E5F
E5
Item ref. Total length L
thickness of top
plates (th)
Accessories/bolts
includedmm mm
Min. pack.
1 p.1 p.
EANcode
191956967322
Weight 100 units
pc. /
76,8578,75
Serie of oblong holes (13x40 mm) on 3 profile sides
Anchor fixing plate included boltsepoxy
for the mounting on straight ceilings
Used for: Profile U 5050/... C1KG
KU 5050 C1KG
7032 105 5 2 SKM 10x25 E5C1
Item ref. RAL colour
Total length L
thickness of top
plates (th)
Accessories/bolts
includedmm mm
Min. pack.
1 p.
EANcode
967315
Weight 100 units
pc
72,7
Serie of oblong holes (13x40 mm) on 3 profile sides
24
SUPPORT SYSTEM
Ceiling supportpultruded, C-profile
Total length = L + 53 millimetersThe ceiling support fixing to the ceiling with screws require the use of a large washer, to beordered separetly
for a mounting on 1 side of the support
Used for: Bracket FPAP…/AC and FPAM…/AC
Mounting accessories required : FPBGV10 V4A ( to be ordered separately )Other lengths are available on request
FPES 200/AC
7032 200 1,5FPES 300/AC 7032 300 1,5FPES 400/AC 7032 400 1,5FPES 500/AC 7032 500 1,5
K23
K23K23K23
Item ref. RAL colour
LengthL
Admissible load
F in tractionmm kN
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
955923955930955947955954
Weight 100 units
pc
7592
110127
Ceiling supportpultruded, double C-profile
Total length = L + 53 millimetersThe ceiling support fixing to the ceiling with screws require the use of a large washer, to beordered separetly
to mount on the both support sides
Used for: Bracket FPAP…/AC and FPAM…/AC
Mounting accessories required : FPBGV10 V4A ( to be ordered separately )Other lengths are available on request
FPDS 200/AC
7032 200 2 x 1,5FPDS 300/AC 7032 300 2 x 1,5FPDS 400/AC 7032 400 2 x 1,5FPDS 500/AC 7032 500 2 x 1,5
K23
K23K23K23
Item ref. RAL colour
LengthL
Admissible load
F in tractionmm kN
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
955886955893955909955916
Weight 100 units
pc
7696
175205
Anchor bolt
for fixing the cables on the C profile
Used for: Bracket FPAP/AC, FPAM/AC and FPAR/AC
FPBGV 10 E4
30E4
Item ref. LengthL
mm
Min. pack.
25 p.
EANcode
962662
Weight 100 units
pc
6,6
25
GRP fixing railpultruded, C-profile, slot width 15 mm, perforated
FPAR 500/AC
7032 500 1,5FPAR 750/AC 7032 750 1,5FPAR 1000/AC 7032 1000 1,5FPAR 2000/AC 7032 2000 1,5
K23
K23K23K23
Item ref. RAL colour
LengthL
Admissible load
F in tractionmm kN
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
955961955978955985955992
Weight 100 units
pc
5276
168244
KK2Cable tray systems available in height 20 50 80 110
KSystemSystem
KKK²K²KCable trays
Dividers
Fittings
Covers
Accessoires
26
CABLE TRAY SYSTEM GFK
The cable tray system K² EBO Systems (hot press moulding) offers the widest and most complete
range of the GRP market. Its unique interlocking and self-adjusting couplers allows a screwless
connection between the cable tray lengths, and a support distance of up to 1.5 m.
Covers
Accessoires
27
Available siderail heights 20 50 80 110
GRP-Cable tray, pressed, perforated KKL 30 30 35 40
GRP-Cable tray, pressed, not perforated KK 30 30 35 40
GRP-Encap, pressed KKKE ––––– 30 35 40
GRP-Splice plate, pressed, horizontal KKGH ––––– 31 35 40
STAINLESS STEEL-Splice plate-horizontal KKIH ––––– 31 36 41
GRP-Divider, pressed KKT... ––––– 31 36 41
GRP-T, pressed, small radius KKSS ––––– 31 36 –––––
GRP-T, pressed, big radius KKST ––––– 31 36 41
GRP-Elbow 45°, pressed, horizontal KKC ––––– 32 37 41
GRP-Elbow 90°, pressed, big radius KKB ––––– 32 37 42
GRP-Elbow 90°, pressed, small radius KKW ––––– 32 37 41
GRP-Reducer, pressed, right KKRR ––––– 32 37 42
GRP-Reducer, pressed, left KKRL ––––– 32 38 42
GRP-Splice plate, vertical KKGV ––––– 33 38 42
STAINLESS STEEL-Splice plate, vertical KKIV ––––– 33 38 42
GRP-Changing elevation KKET ––––– 33 38 43
GRP-Inside elbow 90°, pressed KKBI ––––– 33 39 43
GRP-Outside elbow 90°, pressed KKBA ––––– 34 39 43
GRP-Mounting plate, pressed MP ––––– 34 39 44
Cover clip DF... 50/51
Separating stud TB 52*
Dome head bolt FKM 52*
Hexagon head bolt SKM 52*
Cover fi xing insert DF M 50*
Cover clip DFUB 52*
Covers for cables ladders UL systems are available from page 46.
* suitable for all heights
SYSTEM
ACCESSORIES
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
80 1105020
NEW
28
CABLE TRAY SYSTEM K²
KKST...
KK...
KKB...
KKSS...
KKRR...
KKET...
KKBI...
KKKE...
KKBA...
KKETD...
KKC...
KKETD...
KKD...
29
30
CABLE TRAY SYSTEM K²
GRP cable trayspressed, perforated, equipped with a shaped coupler
KKL 20.050
7032 20 50 3 830K23
Item ref. RAL colour
Height WidthB
Materialthickness
(th)
Operatingcross cut
mm mm mm mm²
Min. pack.
3 m
EANcode
952205
Weight 100 units
m
47
The splice plates KKGH must be fixed on the base.Due to the expansion of the material, the following points during installation must be observed:Please take into account an expansion joint of 8 mm for dilatation.For fixing the cables trays on brackets, you need to drill a 9 mm diameter hole for the fixing of thecable tray base with bolts M6x20 V4A .Warning: the deflection is measured with a junction position between 2 cable trays at a distance L/5from the support. If this distance is not respected, it is necessary to raise the deflection values byapprox. 30%.
GRP cable trayspressed, not perforated, with interlocking coupler,
KK 20.050
7032 20 50 3 830K23
Item ref. RAL colour
Height WidthB
Materialthickness
(th)
Operatingcross cut
mm mm mm mm²
Min. pack.
3 m
EANcode
952007
Weight 100 units
m
47
The splice plates KKGH must be fixed on the baseDue to the expansion of the material, the following points during installation must be observed :Please take into account an expansion joint of 8 mm for dilatation. For the fixing of cable trays onbrackets, a 9 mm diameter hole must be drilled in the cable tray base to fix them with bolts M6x20V4A.Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5from the support. If this distance is not respected, it is necessary to raise the deflection values byapprox. 30%.
GRP cable trayspressed, perforated, equipped with a shaped coupler
KKL 50.050
7032 50 50 0,05 3 1500KKL 50.100 7032 50 100 0,3 3 3700KKL 50.150 7032 50 150 0,3 3 5900KKL 50.200 7032 50 200 0,3 3 8100KKL 50.300 7032 50 300 0,3 3 12500
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
Admissible load
F at L=1,5 m
Materialthickness
(th)
Operatingcross cut
mm mm kN/m mm mm²
Min. pack.
3 m3 m3 m3 m3 m
EANcode
952212952229952236952243952250
Weight 100 units
m
66,494,6
128,0137,4210,0
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5from the support. If this distance is not respected, it is necessary to raise the deflection values byapprox. 30%.
GRP cable trayspressed, not perforated, with interlocking coupler
KK 50.050
7032 50 50 0,05 3 1500KK 50.100 7032 50 100 0,3 3 3700KK 50.150 7032 50 150 0,3 3 5900KK 50.200 7032 50 200 0,3 3 8100KK 50.300 7032 50 300 0,3 3 12500
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
Admissible load
F at L=1,5 m
Materialthickness
(th)
Operatingcross cut
mm mm kN/m mm mm²
Min. pack.
3 m3 m3 m3 m3 m
EANcode
952014952021952038952045952052
Weight 100 units
m
7098
125152210
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5from the support. If this distance is not respected, it is necessary to raise the deflection values byapprox. 30%.
End cap for GRP cable traypressed
for the closing of the cable tray ends
Used for: Cable trays KK…, KKL… H50 mm
Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
KKKE 50.050
7032 50 50KKKE 50.100 7032 50 100KKKE 50.150 7032 50 150KKKE 50.200 7032 50 200KKKE 50.300 7032 50 300
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
955190955206955213955220955237
Weight 100 units
pc
2,06,04,0
11,517,0
31
GRP adjustable splice platepressed, horizontal
Need: 2 pieces for each cut
for the horizontal connection of cable trays and fittings H50 mm lengthwise
Mounting accessories required : 4 bolts M6x20 V4A ( to be ordered separately )
KKGH 50
7032 35K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955626
Weight 100 units
2,4
for the cable tray connection with an expansion joint
Horizontal splice platehorizontal
Need: 2 pieces for each cut
for the horizontal connection of cable trays and fittings H50 mm and for the changes of directions.
Mounting accessories required : 4 bolts M6x16 V4A ( to be ordered separately )
KKIH 50 E4
38E4
Item ref. Height
mm
Min. pack.
1 set
EANcode
955657
Weight 100 units
1,4
for the length adjustment, please leave a space between cable trays.
GRP separatorpressed
The divider KKT 50 is delivered not mounted, it can be fixed in the cable tray with a bolt M 6x16V4A each meter.The divider KKT50/M can be delivered pre-mounted ( riveted ), the position inside the cabletray must be defined in the purchase order.
to separate cables with different functions and / or to separate voltages
KKT 50
7032 42KKT 50/M 7032 42
K23
K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m3 m
EANcode
953028953059
Weight 100 units
m
3838
GRP tee junction for cable tray, small radiuspressed, with interlocking coupler
KKSS 50.050
7032 50 50KKSS 50.100 7032 50 100KKSS 50.150 7032 50 150KKSS 50.200 7032 50 200KKSS 50.300 7032 50 300
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
954780954797954803954810954827
Weight 100 units
pc
1510202530
During the installation, you must take care to position a support at each cable tray end and to fix themwith bolts M 6x16 V4A.
GRP tee junction for cable tray, large radiuspressed, with interlocking coupler
KKST 50.100
7032 50 100KKST 50.150 7032 50 150KKST 50.200 7032 50 200KKST 50.300 7032 50 300
K23
K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
954575954582954599954605
Weight 100 units
pc
60,067,776,6
100,0
During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.
32
CABLE TRAY SYSTEM K²
Horizontal elbow 45°pressed, with interlocking coupler
The piece is provided with a sleeve riveted on one side only.
KKC 50.100
7032 50 100 100KKC 50.150 7032 50 150 175KKC 50.200 7032 50 200 200KKC 50.300 7032 50 300 225
K23
K23K23K23
Item ref. RAL colour
Height WidthB
Radius R
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
953400953417953424953431
Weight 100 units
pc
20253060
To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
Horizontal elbow 90°, small radiuspressed, with interlocking coupler
KKW 50.050
7032 50 50KKW 50.100 7032 50 100KKW 50.150 7032 50 150KKW 50.200 7032 50 200KKW 50.300 7032 50 300
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
953646953653953660953677953684
Weight 100 units
pc
1021354080
During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
Horizontal elbow 90°, large radiuspressed, with interlocking coupler
KKB 50.100
7032 50 100 125 100KKB 50.150 7032 50 150 200 175KKB 50.200 7032 50 200 225 200KKB 50.300 7032 50 300 250 225
K23
K23K23K23
Item ref. RAL colour
Height WidthB
C Radius R
mm mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
953165953172953189953196
Weight 100 units
pc
37,060,070,0
134,8
During the assembly, we recommend to support each end of fitting at each cable entry.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
GRP right hand reductionpressed, with interlocking coupler
KKRR 50.200
7032 50 200KKRR 50.300 7032 50 300
K23
K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.
EANcode
955022955039
Weight 100 units
pc
90114
During the assembly, every reducer must be supported at each end.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
GRP left hand reductionpressed, with interlocking coupler
KKRL 50.200
7032 50 200KKRL 50.300 7032 50 300
K23
K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.
EANcode
954919954926
Weight 100 units
pc
90114
During the assembly, every reducer must be supported at each end.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
33
GRP vertical splice platepressed, horizontal
Need: 2 pieces for each cut
for the vertical connection of cable trays and fittings H50 with an angle adjustment.
Mounting accessories required : 4 bolts M6x20 V4A ( to be ordered separately )
KKGV 50
7032 35K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955138
Weight 100 units
5
Stainless steel vertical splice plate V4Avertical
Need: 2 pieces for each cut
for the horizontal connection of cable trays and fittings H50 mm and for the changes of directions.
Mounting accessories required : 4 bolts M6x16 V4A ( to be ordered separately )
KKIV 50 E4
38E4
Item ref. Height
mm
Min. pack.
1 set
EANcode
955169
Weight 100 units
3
GRP changing elevationpressed, with interlocking coupler
Composed with different pieces, the changing elevation can be mounted in different heights
KKET 50.100
7032 50 100 160 480 800KKET 50.150 7032 50 150 160 480 800KKET 50.200 7032 50 200 160 480 800KKET 50.300 7032 50 300 160 480 800
K23
K23K23K23
Item ref. RAL colour
Height WidthB
HeightH1
HeightH2
HeightH3
mm mm mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
954339954346954353954360
Weight 100 units
pc
210216259263
During the assembly, every fitting must be supported at each end and in the fitting center. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.The part height depends on the height and the configuration usedH1 = 160 mm =>L1 = 785 mm ( a cut is necessary )H2 = 480 mm =>L2 = 1100 mmH3 = 800 mm =>L3 = 970 mm
GRP vertical inside elbowpressed, with interlocking coupler
KKBI 50.050
7032 50 50KKBI 50.100 7032 50 100KKBI 50.150 7032 50 150KKBI 50.200 7032 50 200KKBI 50.300 7032 50 300
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
954025954032954049954056954063
Weight 100 units
pc
11,737,561,077,090,9
During the assembly, we recommend to support each end of fitting at each cable entry.Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
34
CABLE TRAY SYSTEM K²
GRP vertical outside elbowpressed, with interlocking coupler
KKBA 50.050
7032 50 50KKBA 50.100 7032 50 100KKBA 50.150 7032 50 150KKBA 50.200 7032 50 200KKBA 50.300 7032 50 300
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
953837953844953851953868953875
Weight 100 units
pc
11,532,034,951,074,0
During the assembly, we recommend to support each end of fitting at each cable entry.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
Mounting platepressed, easy to install, with pre-mounted fixing clamps
The mounting plate is in GRP, only the mounting lug are in stainless steel V4A
for the installation of equipment or junction boxes
MP 50
7032 50E4 K23
Item ref. RAL colour
Height
mm
Min. pack.
1 p.
EANcode
963010
Weight 100 units
pc
17
35
GRP cable trayspressed, perforated, equipped with a shaped coupler, with reinforced sidewalls (5 mm)
Thanks to the cable trays' straps it can be used for high frequency according to UTEC15-900 (classe D, frequency 16 MHz).L = support distance ( in m )
KKL 80.100
7032 80 100 0,5 3 6500KKL 80.150 7032 80 150 0,5 3 10200KKL 80.200 7032 80 200 0,5 3 13900KKL 80.250 7032 80 250 0,5 3 17600KKL 80.300 7032 80 300 0,5 3 21300KKL 80.400 7032 80 400 1,0 4 27600KKL 80.500 7032 80 500 1,0 4 34800KKL 80.600 7032 80 600 1,0 4 42000
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Admissible load
F at L=1,5 m
Materialthickness
(th)
Operatingcross cut
mm mm kN/m mm mm²
Min. pack.
3 m3 m3 m3 m3 m3 m3 m3 m
EANcode
952267952274952281952298952304952311952328952335
Weight 100 units
m
122,0161,0180,0218,7281,0380,0480,0540,0
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5from the support. If this distance is not respected, it is necessary to raise the deflection values byapprox. 30%.
GRP cable trayspressed, equipped with a shaped coupler, with reinforced sidewalls (5 mm)
Thanks to the cable trays' straps it can be used for high frequency according to UTEC15-900 (classe D, frequency 16 MHz).L = support distance ( in m )
KK 80.100
7032 80 100 0,5 3 6500KK 80.150 7032 80 150 0,5 3 10200KK 80.200 7032 80 200 0,5 3 13900KK 80.250 7032 80 250 0,5 3 17600KK 80.300 7032 80 300 0,5 3 21300KK 80.400 7032 80 400 1,0 4 27600KK 80.500 7032 80 500 1,0 4 34800KK 80.600 7032 80 600 1,0 4 42000
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Admissible load
F at L=1,5 m
Materialthickness
(th)
Operatingcross cut
mm mm kN/m mm mm²
Min. pack.
3 m3 m3 m3 m3 m3 m3 m3 m
EANcode
952069952076952083952090952106952113952120952137
Weight 100 units
m
127165195220230390460470
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5from the support. If this distance is not respected, it is necessary to raise the deflection values byapprox. 30%.
End cap for GRP cable traypressed
for the closing of the cable tray ends
Used for: Cable trays KK…, KKL… H80 mm
Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
KKKE 80.100
7032 80 100KKKE 80.150 7032 80 150KKKE 80.200 7032 80 200KKKE 80.250 7032 80 250KKKE 80.300 7032 80 300KKKE 80.400 7032 80 400KKKE 80.500 7032 80 500KKKE 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
955244955251955268955275955282955299955305955312
Weight 100 units
pc
6,09,0
12,014,017,521,026,035,0
GRP adjustable splice platepressed, horizontal
Need: 2 pieces for each cut
for the horizontal connection of cable trays and fittings H80mm lengthwise
Mounting accessories required : 4 bolts M6x16 V4A ( to be ordered separately )
KKGH 80
7032 65K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955633
Weight 100 units
3,7
for the cable tray connection with an expansion joint
36
CABLE TRAY SYSTEM K²
Horizontal splice platehorizontal
Need: 2 pieces for each cut
for the horizontal connection of cable trays and fittings H80 mm and for the changes of directions.
Mounting accessories required : 4 bolts M6x16 V4A ( to be ordered separately )
KKIH 80 E4
7032 65E4
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955664
Weight 100 units
3,6
for the length adjustment, please leave a space between cable trays.
GRP separatorpressed
The divider KKT 80 is delivered not mounted, it can be fixed in the cable tray with a bolt M 6x16V4A each meter.The divider KKT80/M can be delivered pre-installed (riveted), the position inside the cabletray must be defined in the purchase order.
to separate cables with different functions and / or to separate voltages
KKT 80
7032 67KKT 80/M 7032 67
K23
K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m3 m
EANcode
953035953066
Weight 100 units
m
4040
GRP tee junction for cable tray, small radiuspressed, with interlocking coupler
KKSS 80.100
7032 80 100KKSS 80.150 7032 80 150KKSS 80.200 7032 80 200KKSS 80.250 7032 80 250KKSS 80.300 7032 80 300
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
954834954841954858954865954872
Weight 100 units
pc
1827222832
During the installation, you must take care to position a support at each cable tray end and to fix themwith bolts M 6x16 V4A.
GRP tee junction for cable tray, large radiuspressed, with interlocking coupler
KKST 80.100
7032 80 100KKST 80.150 7032 80 150KKST 80.200 7032 80 200KKST 80.250 7032 80 250KKST 80.300 7032 80 300KKST 80.400 7032 80 400KKST 80.500 7032 80 500KKST 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
954612954629954636954643954650954667954674954681
Weight 100 units
pc
78,088,090,0
101,0108,5130,0145,0164,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.
37
Horizontal elbow 45°pressed, with interlocking coupler
The piece is provided with a sleeve riveted on one side only.
KKC 80.100
7032 80 100 100KKC 80.150 7032 80 150 175KKC 80.200 7032 80 200 200KKC 80.250 7032 80 250 275KKC 80.300 7032 80 300 225KKC 80.400 7032 80 400 250KKC 80.500 7032 80 500 250KKC 80.600 7032 80 600 250
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Radius R
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
953448953455953462953479953486953493953509953516
Weight 100 units
pc
22,029,550,070,0
100,0151,0280,0300,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
Horizontal elbow 90°, small radiuspressed, with interlocking coupler
KKW 80.100
7032 80 100KKW 80.150 7032 80 150KKW 80.200 7032 80 200KKW 80.250 7032 80 250KKW 80.300 7032 80 300KKW 80.400 7032 80 400KKW 80.500 7032 80 500KKW 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
953691953707953714953721953738953745953752953769
Weight 100 units
pc
2735536286
125195240
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
Horizontal elbow 90°, large radiuspressed, with interlocking coupler
KKB 80.100
7032 80 100 125 100KKB 80.150 7032 80 150 200 175KKB 80.200 7032 80 200 225 200KKB 80.250 7032 80 250 300 275KKB 80.300 7032 80 300 250 225KKB 80.400 7032 80 400 325 250KKB 80.500 7032 80 500 325 250KKB 80.600 7032 80 600 325 250
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
C Radius R
mm mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
953202953219953226953233953240953257953264953271
Weight 100 units
pc
41,543,590,0
146,5170,0272,0377,0442,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
GRP right hand reductionpressed, with interlocking coupler
KKRR 80.200
7032 80 200KKRR 80.300 7032 80 300KKRR 80.400 7032 80 400KKRR 80.500 7032 80 500KKRR 80.600 7032 80 600
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
955046955053955060955077955084
Weight 100 units
pc
92124165190220
During the assembly, every reducer must be supported at each end.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
38
CABLE TRAY SYSTEM K²
GRP left hand reductionpressed, with interlocking coupler
KKRL 80.200
7032 80 200KKRL 80.300 7032 80 300KKRL 80.400 7032 80 400KKRL 80.500 7032 80 500KKRL 80.600 7032 80 600
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
954933954940954957954964954971
Weight 100 units
pc
92114163184220
During the assembly, every reducer must be supported at each end.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
GRP vertical splice platepressed, vertical
Need: 2 pieces for each cut
for the vertical connection of cable trays and fittings H80 with an angle adjustment.
Mounting accessories required : 4 bolts M6x20 V4A ( to be ordered separately )
KKGV 80
7032 65K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955145
Weight 100 units
9
Stainless steel vertical splice plate V4Avertical
Need: 2 pieces for each cut
for the horizontal connection of cable trays and fittings H80 mm and for the changes of directions.
Mounting accessories required : 4 bolts M6x16 V4A ( to be ordered separately )
KKIV 80 E4
65E4
Item ref. Height
mm
Min. pack.
1 set
EANcode
955176
Weight 100 units
8
GRP changing elevationpressed, with interlocking coupler
Composed with different pieces, the changing elevation can be mounted in different heights
KKET 80.100
7032 80 100 160 480 800KKET 80.150 7032 80 150 160 480 800KKET 80.200 7032 80 200 160 480 800KKET 80.250 7032 80 250 160 480 800KKET 80.300 7032 80 300 160 480 800KKET 80.400 7032 80 400 160 480 800KKET 80.500 7032 80 500 160 480 800KKET 80.600 7032 80 600 160 480 800
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
HeightH1
HeightH2
HeightH3
mm mm mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
954377954384954391954407954414954421954438954445
Weight 100 units
pc
190250259340344420500596
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.The part height depends on the height and the configuration usedH1 = 160 mm =>L1 = 785 mm ( a cut is necessary )H2 = 480 mm =>L2 = 1100 mmH3 = 800 mm =>L3 = 970 mm
39
GRP vertical inside elbowpressed, with interlocking coupler
KKBI 80.100
7032 80 100KKBI 80.150 7032 80 150KKBI 80.200 7032 80 200KKBI 80.250 7032 80 250KKBI 80.300 7032 80 300KKBI 80.400 7032 80 400KKBI 80.500 7032 80 500KKBI 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
954070954087954094954100954117954124954131954148
Weight 100 units
pc
53647590
102123145170
During the assembly, we recommend to support each end of fitting at each cable entry.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
GRP vertical outside elbowpressed, with interlocking coupler
KKBA 80.100
7032 80 100KKBA 80.150 7032 80 150KKBA 80.200 7032 80 200KKBA 80.250 7032 80 250KKBA 80.300 7032 80 300KKBA 80.400 7032 80 400KKBA 80.500 7032 80 500KKBA 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
953882953899953905953912953929953936953943953950
Weight 100 units
pc
4655627374
100113134
During the assembly, we recommend to support each end of fitting at each cable entry.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
Mounting platepressed, easy to install, with pre-mounted fixing clamps
The mounting plate is in GRP, only the mounting lug are in stainless steel V4A
for the installation of equipment or junction boxes
MP 80
7032 80E4 K23
Item ref. RAL colour
Height
mm
Min. pack.
1 p.
EANcode
963027
Weight 100 units
pc
17
40
CABLE TRAY SYSTEM K²
GRP cable trayspressed, perforated, equipped with a shaped coupler, with reinforced sidewalls (5 mm)
Thanks to the cable trays' straps it can be used for high frequency according to UTEC15-900 (classe D, frequency 16 MHz).L = support distance ( in m )
KKL 110.100
7032 110 100 1,2 4 8500KKL 110.200 7032 110 200 1,2 4 18800KKL 110.300 7032 110 300 1,2 4 29100KKL 110.400 7032 110 400 1,2 4 39400KKL 110.500 7032 110 500 1,2 4 49700KKL 110.600 7032 110 600 1,2 4 60000
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Admissible load
F at L=1,5 m
Materialthickness
(th)
Operatingcross cut
mm mm kN/m mm mm²
Min. pack.
3 m3 m3 m3 m3 m3 m
EANcode
952342952359952366952373952380952397
Weight 100 units
m
230300370440510580
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5from the support. If this distance is not respected, it is necessary to raise the deflection values byapprox. 30%.
GRP cable trayspressed, equipped with a shaped coupler, with reinforced sidewalls (5 mm)
Thanks to the cable trays' straps it can be used for high frequency according to UTEC15-900 (classe D, frequency 16 MHz).L = support distance ( in m )
KK 110.100
7032 110 100 1,2 4 8500KK 110.200 7032 110 200 1,2 4 18800KK 110.300 7032 110 300 1,2 4 29100KK 110.400 7032 110 400 1,2 4 39400KK 110.500 7032 110 500 1,2 4 49700KK 110.600 7032 110 600 1,2 4 60000
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Admissible load
F at L=1,5 m
Materialthickness
(th)
Operatingcross cut
mm mm kN/m mm mm²
Min. pack.
3 m3 m3 m3 m3 m3 m
EANcode
952144952151952168952175952182952199
Weight 100 units
m
230300380450520600
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5from the support. If this distance is not respected, it is necessary to raise the deflection values byapprox. 30%.
End cap for GRP cable traypressed
for the closing of the cable tray ends
Used for: Cable trays KK…, KKL… H110 mm
Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
KKKE 110.100
7032 110 100KKKE 110.200 7032 110 200KKKE 110.300 7032 110 300KKKE 110.400 7032 110 400KKKE 110.500 7032 110 500KKKE 110.600 7032 110 600
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
955329955336955343955350955367955374
Weight 100 units
pc
101318222726
GRP adjustable splice platepressed, horizontal
Need: 2 pieces for each cut
for the horizontal connection of cable trays and fittings H110 mm lengthwise
Mounting accessories required : 4 bolts M6x20 V4A ( to be ordered separately )
KKGH 110
7032 89K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955640
Weight 100 units
2
for the cable tray connection with an expansion joint
41
Horizontal splice platehorizontal
Need: 2 pieces for each cut
Mounting accessories required : 4 bolts M6x16 V4A ( to be ordered separately )
KKIH 110 E4
80E4
Item ref. Height
mm
Min. pack.
1 set
EANcode
955671
Weight 100 units
16,6
for the length adjustment, please leave a space between cable trays.
GRP separatorpressed
The divider KKT 110 is delivered not mounted, it can be fixed in the cable tray with a boltM 6x16 V4A each meter.The divider KKT110/M can be delivered pre-mounted ( riveted ), the position inside the cabletray must be defined in the purchase order.
to separate cables with different functions and / or to separate voltages
KKT 110
7032 102KKT 110/M 7032 102
K23
K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m3 m
EANcode
953042953073
Weight 100 units
pc m/
4040
GRP tee junction for cable tray, large radiuspressed, with interlocking coupler
KKST 110.100
7032 110 100KKST 110.200 7032 110 200KKST 110.300 7032 110 300KKST 110.400 7032 110 400KKST 110.500 7032 110 500KKST 110.600 7032 110 600
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
954698954704954711954728954735954742
Weight 100 units
pc
78,0120,0128,5200,0170,0190,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.
Horizontal elbow 45°pressed, with interlocking coupler
The piece is provided with a sleeve riveted on one side only.
KKC 110.100
7032 110 100 200KKC 110.200 7032 110 200 200KKC 110.300 7032 110 300 225KKC 110.400 7032 110 400 250KKC 110.500 7032 110 500 250KKC 110.600 7032 110 600 250
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Radius R
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
953523953530953547953554953561953578
Weight 100 units
pc
22,065,0
108,5197,0313,0342,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mm
Horizontal elbow 90°, small radiuspressed, with interlocking coupler
KKW 110.100
7032 110 100KKW 110.200 7032 110 200KKW 110.300 7032 110 300KKW 110.400 7032 110 400KKW 110.500 7032 110 500KKW 110.600 7032 110 600
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
953776953783953790953806953813953820
Weight 100 units
pc m/
407086
125195240
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mm
42
CABLE TRAY SYSTEM K²
Horizontal elbow 90°, large radiuspressed, with interlocking coupler
KKB 110.100
7032 110 100 125 100KKB 110.200 7032 110 200 225 200KKB 110.300 7032 110 300 250 225KKB 110.400 7032 110 400 325 250KKB 110.500 7032 110 500 325 250KKB 110.600 7032 110 600 325 250
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
C Radius R
mm mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
953288953295953301953318953325953332
Weight 100 units
pc
98,0132,5217,0360,0490,0434,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
GRP right hand reductionpressed, with interlocking coupler
KKRR 110.200
7032 110 200KKRR 110.300 7032 110 300KKRR 110.400 7032 110 400KKRR 110.500 7032 110 500KKRR 110.600 7032 110 600
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
962549955091955107955114955121
Weight 100 units
pc
100124160180240
During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
GRP left hand reductionpressed, with interlocking coupler
KKRL 110.200
7032 110 200 500KKRL 110.300 7032 110 300 500KKRL 110.400 7032 110 400 500KKRL 110.500 7032 110 500 500KKRL 110.600 7032 110 600 500
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
Coverslength
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
962532954988954995955008955015
Weight 100 units
pc m/
100124200195220
During the assembly, we recommend to support each end of fitting at each cable entry.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
GRP vertical splice platepressed, vertical
Need: 2 pieces for each cut
for the vertical connection of cable trays and fittings H110 with an angle adjustment.
Mounting accessories required : 4 bolts M6x20 V4A ( to be ordered separately )
KKGV 110
7032 90K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955152
Weight 100 units
19
Stainless steel vertical splice plate V4Avertical, stainless steel
Need: 2 pieces for each cut
for the horizontal connection of cable trays and fittings H110 mm and for the changes of directions.
Mounting accessories required : 4 bolts M6x16 V4A ( to be ordered separately )
KKIV 110 E4
80E4
Item ref. Height
mm
Min. pack.
1 set
EANcode
955183
Weight 100 units
36
43
GRP changing elevationpressed, with interlocking coupler
Composed with different pieces, the changing elevation can be mounted in different heights
KKET 110.100
7032 110 100 160 480 800KKET 110.200 7032 110 200 160 480 800KKET 110.300 7032 110 300 160 480 800KKET 110.400 7032 110 400 160 480 800KKET 110.500 7032 110 500 160 480 800KKET 110.600 7032 110 600 160 480 800
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
HeightH1
HeightH2
HeightH3
mm mm mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
954452954469954476954483954490954506
Weight 100 units
pc
190210344420480596
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.The part height depends on the height and the configuration usedH1 = 160 mm =>L1 = 785 mm ( a cut is necessary )H2 = 480 mm =>L2 = 1100 mmH3 = 800 mm =>L3 = 970 mm
GRP vertical inside elbowpressed, with interlocking coupler
KKBI 110.100
7032 110 100KKBI 110.200 7032 110 200KKBI 110.300 7032 110 300KKBI 110.400 7032 110 400KKBI 110.500 7032 110 500KKBI 110.600 7032 110 600
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
954155954162954179954186954193954209
Weight 100 units
pc
53100123143175170
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
GRP vertical outside elbowpressed, with interlocking coupler
KKBA 110.100
7032 110 100KKBA 110.200 7032 110 200KKBA 110.300 7032 110 300KKBA 110.400 7032 110 400KKBA 110.500 7032 110 500KKBA 110.600 7032 110 600
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
953967953974953981953998954001954018
Weight 100 units
pc
4682
110130205138
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
44
CABLE TRAY SYSTEM K²
Mounting platepressed, easy to install, with pre-mounted fixing clamps
The mounting plate is in GRP, only the mounting lug are in stainless steel V4A
for the installation of equipment or junction boxes
MP 110
7032 110E4 K23
Item ref. RAL colour
Height
mm
Min. pack.
1 p.
EANcode
963034
Weight 100 units
pc
17
45
NOTES
46
CABLE TRAY SYSTEM COVERS K²
Cover for cable trays and cable ladderspressed
For a stronger assembly, the covers with a width above 400 mm are strengthened. Thesestrengthenings / ribs are visible on the outside face of the part.Used for: Cable tray H50, H80 and H110 mm, KK…, KKL… and cable ladder UL…H53, H80, H100
and H150 mm
KKD 100
7032 100KKD 150 7032 150KKD 200 7032 200KKD 250 7032 250KKD 300 7032 300KKD 400 7032 400KKD 500 7032 500KKD 600 7032 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
3 m3 m3 m3 m3 m3 m3 m3 m
EANcode
956111956128956135956142956159956166956180956197
Weight 100 units
pc
78105132152190243292338
For a strong and compliant assembly, we recommend to leave a minimum distance of 8 mm betweenthe covers and the sidewalls of cable trays. Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for horizontal elbow 45°, small radiuspressed
Used for: Elbow 45° H50, H80 and H110 mm, KKC… and KPC…/P
KKCD 100
7032 100KKCD 150 7032 150KKCD 200 7032 200KKCD 250 7032 250KKCD 300 7032 300KKCD 400 7032 400KKCD 500 7032 500KKCD 600 7032 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956456956463956470956487956494956500956517956524
Weight 100 units
pc
1223335051
138150173
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
Cover for horizontal elbow 90°, large radiuspressed
Used for: Horizontal elbow 90°, large radius, H50, H80 and H110, KKB… and KPB…/P
KKBD 100
7032 100KKBD 150 7032 150KKBD 200 7032 200KKBD 250 7032 250KKBD 300 7032 300KKBD 400 7032 400KKBD 500 7032 500KKBD 600 7032 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956371956388956395956401956418956425956432956449
Weight 100 units
pc
19,543,068,097,0
115,0241,0334,0403,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
47
Cover for horizontal elbow 90°, small radiuspressed
Used for: Horizontal elbow 90°, H50, H80 and H110, KKW…
KKWD 50
7032 50KKWD 100 7032 100KKWD 150 7032 150KKWD 200 7032 200KKWD 250 7032 250KKWD 300 7032 300KKWD 400 7032 400KKWD 500 7032 500KKWD 600 7032 600
K23
K23K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956531956548956555956562956579956586956593956609956616
Weight 100 units
pc
6,011,521,031,041,560,093,0
125,0187,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for vertical inside elbowpressed
Used for: Vertical inside elbow 50 mm high, KKBI… and KPBI…/P
KKBID 50.050
7032 50 50KKBID 50.100 7032 50 100KKBID 50.150 7032 50 150KKBID 50.200 7032 50 200KKBID 50.300 7032 50 300
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
956814956821956838956845956852
Weight 100 units
pc
520425063
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for vertical inside elbowpressed
Used for: Vertical inside elbow 80 mm high, KKBI… and KPBI…/P
KKBID 80.100
7032 80 100KKBID 80.150 7032 80 150KKBID 80.200 7032 80 200KKBID 80.250 7032 80 250KKBID 80.300 7032 80 300KKBID 80.400 7032 80 400KKBID 80.500 7032 80 500KKBID 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956869956876956883956890956906956913956920956937
Weight 100 units
pc
18,024,533,040,045,561,073,095,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for vertical inside elbowpressed
Used for: Vertical inside elbow 110 mm high, KKBI… and KPBI…/P
KKBID 110.100
7032 110 100KKBID 110.200 7032 110 200KKBID 110.300 7032 110 300KKBID 110.400 7032 110 400KKBID 110.500 7032 110 500KKBID 110.600 7032 110 600
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956944956951956968956975956982956999
Weight 100 units
pc
183050
100120130
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
48
CABLE TRAY SYSTEM COVERS K²
GRP cover for vertical outside elbowpressed
Used for: Vertical outside elbow H50 mm, KKBA… and KPBA…/P
KKBAD 50.050
7032 50 50KKBAD 50.100 7032 50 100KKBAD 50.150 7032 50 150KKBAD 50.200 7032 50 200KKBAD 50.300 7032 50 300
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
956623956630956647956654956661
Weight 100 units
pc
7,810,042,051,065,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for vertical outside elbowpressed
Used for: Vertical outside elbow H80 mm, KKBA… and KPBA…/P
KKBAD 80.100
7032 80 100KKBAD 80.150 7032 80 150KKBAD 80.200 7032 80 200KKBAD 80.250 7032 80 250KKBAD 80.300 7032 80 300KKBAD 80.400 7032 80 400KKBAD 80.500 7032 80 500KKBAD 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956678956685956692956708956715956722956739956746
Weight 100 units
pc
29,539,051,061,072,090,0
120,0136,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for vertical outside elbowpressed
Used for: Vertical outside elbow H110 mm, KKBA… and KPBA…/P
KKBAD 110.100
7032 110 100KKBAD 110.200 7032 110 200KKBAD 110.300 7032 110 300KKBAD 110.400 7032 110 400KKBAD 110.500 7032 110 500KKBAD 110.600 7032 110 600
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956753956760956777956784956791956807
Weight 100 units
pc
35507080
120130
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for changing elevationpressed
1 KKETD is composed of :- 1 GRP cover for inside elbow- 1 GRP cover for outside elbowUsed for: Changing elevation H50 mm KKET… and KPET…/P
KKETD 50.100
7032 50 100KKETD 50.150 7032 50 150KKETD 50.200 7032 50 200KKETD 50.300 7032 50 300
K23
K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
957002957019957026957033
Weight 100 units
pc
20414060
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
49
GRP cover for changing elevationpressed
1 KKETD is composed of :- 1 GRP cover for inside elbow- 1 GRP cover for outside elbowUsed for: Changing elevation H50 mm KKET… and KPET…/P
KKETD 80.100
7032 80 100KKETD 80.150 7032 80 150KKETD 80.200 7032 80 200KKETD 80.250 7032 80 250KKETD 80.300 7032 80 300KKETD 80.400 7032 80 400KKETD 80.500 7032 80 500KKETD 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957040957057957064957071957088957095957101957118
Weight 100 units
pc
23,531,740,544,047,061,098,0
120,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for changing elevationpressed
1 KKETD is composed of :- 1 GRP cover for inside elbow- 1 GRP cover for outside elbowUsed for: Changing elevation H110 mm KKET…
KKETD 110.100
7032 110 100KKETD 110.200 7032 110 200KKETD 110.300 7032 110 300KKETD 110.400 7032 110 400KKETD 110.500 7032 110 500KKETD 110.600 7032 110 600
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957125957132957149957156957163957170
Weight 100 units
pc
23,540,047,061,098,0
120,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for tee junction, large radiuspressed, with interlocking coupler
Used for: Cover for tee junction for H50, H80 and H110 mm, KKST… and KPST…/P
KKSTD 100
7032 100KKSTD 150 7032 150KKSTD 200 7032 200KKSTD 250 7032 250KKSTD 300 7032 300KKSTD 400 7032 400KKSTD 500 7032 500KKSTD 600 7032 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957187957194957200957217957224957231957248957255
Weight 100 units
pc
354252636578
100118
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
Tee junction cover, small radiuspressed, with interlocking coupler
Used for: Tee junction for H50 and H80 mm, KKSS… and KPSS…/P
KKSSD 50
7032 50KKSSD 100 7032 100KKSSD 150 7032 150KKSSD 200 7032 200KKSSD 250 7032 250KKSSD 300 7032 300
K23
K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957262957279957286957293957309957316
Weight 100 units
pc
5,08,09,5
13,014,515,5
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
50
CABLE TRAY SYSTEM COVERS K²
GRP cover for right hand reductionpressed
Used for: Right hand reduction H50, H80 and H110 mm, KKRR…
KKRRD 200
7032 200KKRRD 300 7032 300KKRRD 400 7032 400KKRRD 500 7032 500KKRRD 600 7032 600
K23
K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
957378957385957392957408957415
Weight 100 units
pc
50,579,0
119,0131,0160,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for left hand reductionpressed
Used for: Reduction H50, 80 and 110 mm, KKRL…
KKRLD 200
7032 200KKRLD 300 7032 300KKRLD 400 7032 400KKRLD 500 7032 500KKRLD 600 7032 600
K23
K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
957323957330957347957354957361
Weight 100 units
pc
4975
110147160
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
Cover fixing clipstainless steel
for fixing the cables tray covers and fittings
Used for: Cable tray cover KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... and KKRRD...
DF 50 E4
55DF 80 E4 85DF 100 E4 110
E4
E4E4
Item ref. Height
mm
Min. pack.
50 p.50 p.50 p.
EANcode
957873957880957897
Weight 100 units
pc.
1,72,12,3
Under normal conditions, it is recommended to mount 1 clip each meter alternatively every 3 meters.Under extreme weather conditions, such as strong winds or storms, the quantity of clips must beincreased.
Cover fixing
Used for: Cover for cable tray KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... und KKRRD…
DF M
K01
Item ref. Min. pack.
50 p.
EANcode
957927
Weight 100 units
pc.
0,2
For fixing the cover, it is necessary to drill a 8,2 mm diameter hole for the diameter. In extremeweather conditions such as strong winds, for example, the quantity of clips must be increased.
Cover fixing
Used for: Cover for cable tray KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... und KKRRD…
DFUB 5.5X19 E4
N E4
Item ref. Min. pack.
50 p.
EANcode
062065
Weight 100 units
0,64
For fixing the cover, it is necessary to drill a 8,2 mm diameter hole for the diameter. In extremeweather conditions such as strong winds, for example, the quantity of clips must be increased.
51
Cover fixing clipstainless steel
for fixing the cables tray covers and fittings
Used for: Cable tray cover KKD…
DF 1060 E4
E4
Item ref. Min. pack.
50 p.
EANcode
957910
Weight 100 units
pc.
1,1
Under normal conditions, it is recommended to mount 1 clip each meter alternatively every 3 meters.Under extreme weather conditions, such as strong winds or storms, the quantity of clips must beincreased.
52
CABLE TRAY SYSTEM ACCESSOIRES K²
Separating studpultruded
Not suitable when the cable tray is mounted vertically (not horizontally)
for an easy mounting of cables and connections
TB
K01
Item ref. Min. pack.
1 p.
EANcode
957934
Weight 100 units
m
1
When mounting the separating stud, it is necesary to drill a 10 mm hole diameter in the base.
Dome head boltIncluded nut and washer
Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4
FKM 6X16 E4
6 16FKM 6X20 E4 6 20
E4
E4
Item ref. ThreadM
LengthL
mm
Min. pack.
100 p.100 p.
EANcode
962693962709
Weight 100 units
pc
1,21,4
Dome head boltIncluded nut and washer
Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4
FKM 8X20 K01
8 20K01
Item ref. ThreadM
LengthL
mm
Min. pack.
100 p.
EANcode
962716
Weight 100 units
pc
0,4
Hexagon head boltIncluded nut and washer
Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4
SKM 10X30 E4
10 30SKM 10X40 E4 10 40
E4
E4
Item ref. ThreadM
LengthL
mm
Min. pack.
100 p.100 p.
EANcode
962730962747
Weight 100 units
pc
4,55,1
53
NOTES
KPKPKPKPCable trays
Dividers
Fittings
Covers
Accessoires
Cable tray systems available in height 50 80 110
KPSystemSystem
KPKPKPKPKP54
CABLE TRAY SYSTEM GFK
The cable tray system KP EBO Systems (manufactured by pultrusion) provides maximum fl exibility
and effi ciency and a support distance of up to 4 m.
Its quickly assembly with clip in jointing pieces without screws included automatically an expansion
joint, greatly facilitates its installation.
Covers
Accessoires
55
Available siderail heights
GRP-Cable tray, pultruded, perfored KPL 58 58 62
GRP-Cable tray, pultruded, no-perfored KP 58 58 62
GRP-Encap, pultruded KPKE 59 59 63
GRP-Splice plate, pultruded, horizontal KPGH... 59 59 63
STAINLESS STEEL-Splice plate, horizontal KPIH 59 ––––– –––––
GRP-Divider, pultruded KPT... ––––– 59 63
GRP-T, pultruded, small radius KPSS ––––– 59 –––––
GRP-T, pultruded, big radius KPST ––––– ––––– 63
GRP-Elbow 45°, pressed, horizontal KPC ––––– 60 63
GRP-Elbow 90°, pressed, big radius KPB ––––– 60 64
GRP-Changing elevation, pressed KPET ––––– 60 64
GRP-Exterior changing elevation, pressed KPBI ––––– 60 64
GRP-Interior changing elevation, pressed KPBA ––––– 61 64
Cover clip DF... 69
Cover fi xing insert DF M 69*
Cover clip DFUB 69*
Rack, pressed KR 70*
Separating stud TB 70*
Dome head bolt FKM 70*
Hexagon head bolt SKM 70*
Covers for cables ladders UL systems are available from page 66.
SYSTEM
ACCESSORIES
* suitable for all heights
50 80 40
805040
805040
805040
805040
805040
805040
805040
805040
805040
805040
805040
805040
805040
NEW
56
CABLE TRAY SYSTEM KP
KPL...
KP...
KPKE...
KPB...
KPBA...
KPST...
KPT...
KPD...
KPET...
KPBI...
57
58
CABLE TRAY SYSTEM KP
GRP cable trayspultruded, perforated
L = fixing distance (m)
Load
q (k
N/m
)
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5 from thesupport. If this distance is not respected, it is necessary to raise the deflection values by approx. 30%.
The splice plates KPGH 50/ KPIH 50 V4A are not included in the cables trays, please order themseparately.
Load diagram : q = load evenly distributed cables (according to DIN EN IEC 61537 standard)
KPL 40.060
7032 40 60 2,0KPL 50.100 7032 50 100 2,5KPL 50.150 7032 50 150 2,5KPL 50.200 7032 50 200 2,5KPL 40.060/6 7032 40 60 2,0KPL 50.100/6 7032 50 100 2,5KPL 50.150/6 7032 50 150 2,5KPL 50.200/6 7032 50 200 2,5
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Materialthickness
(th)mm mm mm
Min. pack.
3 m3 m3 m3 m6 m6 m6 m6 m
EANcode
952557952564952571952588952632952649952656952663
Weight 100 units
pc m/
60,0104,1130,0166,060,0
104,1130,0166,0
Due to the expansion of the material, the following points during installation must be observed :The supporting systems must not be fixed close to the splice platesFor fixing the cables trays on brackets, you need to drill a 9 mm diameter hole for the fixing of thecable tray base with bolts M6x20 V4AWhen fixing the splice plates KPGH… and KPIH..., an expansion distance of about 3 mm must beconsidered.
GRP cable trayspultruded, not perforated
The splice plates KPGH 50/ KPIH 50 V4A are not included in the cables trays, please order themseparately.
KP 40.060
7032 40 60 2,0KP 50.100 7032 50 100 2,5KP 50.150 7032 50 150 2,5KP 50.200 7032 50 200 2,5KP 40.060/6 7032 40 60 2,0KP 50.100/6 7032 50 100 2,5KP 50.150/6 7032 50 150 2,5KP 50.200/6 7032 50 200 2,5
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Materialthickness
(th)mm mm mm
Min. pack.
3 m3 m3 m3 m6 m6 m6 m6 m
EANcode
967612952403952410952427952472952489952496952502
Weight 100 units
pc m/
6210013116260
100131162
Due to the expansion of the material, the following points during installation must be observed :The supporting systems must not be fixed close to the splice platesFor fixing the cables trays on brackets, you need to drill a 9 mm diameter hole for the fixing of thecable tray base with bolts M6x20 V4AWhen fixing the splice plates KPGH… and KPIH..., an expansion distance of about 3 mm must beconsidered.
59
End cap for cable traypultruded
for the cable tray ends
Used for: Cable tray H50, H80, KP…, KPL… and cable truncking LFG…
Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
KPKE 40.060
7032 40 60KPKE 50.100 7032 50 100KPKE 50.150 7032 50 150KPKE 50.200 7032 50 200
K23
K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
955381955398955404955411
Weight 100 units
pc
5,56,09,0
10,0
Clipsable splice platepressed, horizontal, fixing with bolts
for the connection of cable trays and fittings H40, with splice plates H40
Mounting accessories required : 2 bolts M6x20 V4A ( to be ordered separately )
KPGH 40
7032 25K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955695
Weight 100 units
4,5
During the assembly, an expansion gap of 3 mm for dilatation must be considered.
Clipsable splice platepultruded, horizontal
for the connection of cable trays and fittings H50, with splice plates H50During the assembly, an expansion gap of 3 mm is automatically taken in consideration.
KPGH 50
7032 39K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955701
Weight 100 units
6
Splice platehorizontal, stainless steel
Mounting accessories required : 2 bolts M6x20 V4A ( to be ordered separately )
KPIH 40 E5
40E5
Item ref. Height
mm
Min. pack.
1 set
EANcode
955688
Weight 100 units
2,3
During the assembly, an expansion gap of 3 mm for dilatation must be considered.
Separatorpultruded
The divider KPT50 is delivered not mounted, it can be fixed in the cable tray with a boltM 6x16V4A each meter.The divider KPT50/M could be delivered pre-installed (riveted), the position inside the cabletray should be defined with the order.
to separate cables with different functions and / or to separate voltages
KPT 50
7032 37KPT 50/M 7032 37
K23
K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m3 m
EANcode
953127953141
Weight 100 units
m
3636
GRP tee junction, small radiuspressed, with interlocking coupler
KPSS 50.100/P
7032 50 100KPSS 50.150/P 7032 50 150KPSS 50.200/P 7032 50 200
K23
K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.
EANcode
954889954896954902
Weight 100 units
pc
303540
During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.
60
CABLE TRAY SYSTEM KP
GRP elbow 45°, small radiuspressed, with interlocking coupler
KPC 50.100/P
7032 50 100 100KPC 50.150/P 7032 50 150 175KPC 50.200/P 7032 50 200 200
K23
K23K23
Item ref. RAL colour
Height WidthB
Radius R
mm mm mm
Min. pack.
1 p.1 p.1 p.
EANcode
953585953592953608
Weight 100 units
pc
153040
During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.
GRP elbow 90°, large radiuspressed, with interlocking coupler
KPB 50.100/P
7032 50 100 125 100KPB 50.150/P 7032 50 150 200 175KPB 50.200/P 7032 50 200 225 200
K23
K23K23
Item ref. RAL colour
Height WidthB
C Radius R
mm mm mm mm
Min. pack.
1 p.1 p.1 p.
EANcode
953349953356953363
Weight 100 units
pc
306080
During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.
GRP changing elevationpressed, in 2 pieces, with interlocking coupler
Composed with different pieces, the changing elevation can be mounted in different heights
KPET 50.100/P
7032 50 100 160 480 800KPET 50.150/P 7032 50 150 160 480 800KPET 50.200/P 7032 50 200 160 480 800
K23
K23K23
Item ref. RAL colour
Height WidthB
HeightH1
HeightH2
HeightH3
mm mm mm mm mm
Min. pack.
1 p.1 p.1 p.
EANcode
954513954520954537
Weight 100 units
pc m/
180184259
During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.The part height depends on the height and the configuration usedH1 = 160 mm =>L1 = 785 mm ( a cut is necessary )H2 = 480 mm =>L2 = 1100 mmH3 = 800 mm =>L3 = 970 mm
GRP vertical inside elbowpressed, with interlocking coupler
KPBI 50.100/P
7032 50 100KPBI 50.150/P 7032 50 150KPBI 50.200/P 7032 50 200
K23
K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.
EANcode
954278954285954292
Weight 100 units
pc
405060
During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
61
GRP vertical outside elbowpressed, with interlocking coupler
KPBA 50.100/P
7032 50 100KPBA 50.150/P 7032 50 150KPBA 50.200/P 7032 50 200
K23
K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.
EANcode
954216954223954230
Weight 100 units
pc
304050
During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.
62
CABLE TRAY SYSTEM KP
GRP cable trayspultruded, perforated
L = fixing distance (m)
Load
q (k
N/m
)
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5 from thesupport. If this distance is not respected, it is necessary to raise the deflection values by approx. 30%.
The splice plates KPGH…/ KPIH… V4A are not included in the cables trays, please order themseparately.
Load diagram : q = load evenly distributed cables (according to DIN EN IEC 61537 standard)
KPL 80.100
7032 80 100 2,5KPL 80.150 7032 80 150 2,5KPL 80.200 7032 80 200 2,5KPL 80.300 7032 80 300 3,2KPL 80.100/6 7032 80 100 2,5KPL 80.150/6 7032 80 150 2,5KPL 80.200/6 7032 80 200 2,5KPL 80.300/6 7032 80 300 3,2
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Materialthickness
(th)mm mm mm
Min. pack.
3 m3 m3 m3 m6 m6 m6 m6 m
EANcode
952595952601952618952625952670952687952694952700
Weight 100 units
m
180200234355180200234355
Due to the expansion of the material, the following points during installation must be observed :The supporting systems must not be fixed close to the splice platesFor fixing the cables trays on brackets, you need to drill a 9 mm diameter hole for the fixing of thecable tray base with bolts M6x20 V4AWhen fixing the splice plates KPGH…, an expansion distance of about 3 mm must be considered.
GRP cable trayspultruded, not perforated
The splice plates KPGH…/ KPIH… V4A are not included in the cables trays, please order themseparately.
KP 80.100
7032 80 100 2,5KP 80.150 7032 80 150 2,5KP 80.200 7032 80 200 2,5KP 80.300 7032 80 300 3,2KP 80.100/6 7032 80 100 2,5KP 80.150/6 7032 80 150 2,5KP 80.200/6 7032 80 200 2,5KP 80.300/6 7032 80 300 3,2
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Materialthickness
(th)mm mm mm
Min. pack.
3 m3 m3 m3 m6 m6 m6 m6 m
EANcode
952434952441952458952465952519952526952533952540
Weight 100 units
m
148200240363148200240363
Due to the expansion of the material, the following points during installation must be observed :The supporting systems must not be fixed close to the splice platesFor fixing the cables trays on brackets, you need to drill a 9 mm diameter hole for the fixing of thecable tray base with bolts M6x20 V4AWhen fixing the splice plates KPGH…, an expansion distance of about 3 mm must be considered.
63
End cap for cable traypultruded
for the cable tray ends
Used for: Cable tray H50, H80, KP…, KPL… and cable truncking LFG…
Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
KPKE 80.100
7032 80 100KPKE 80.150 7032 80 150KPKE 80.200 7032 80 200KPKE 80.300 7032 80 300
K23
K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
955428955435955442955459
Weight 100 units
pc
8111320
Clipsable splice platepultruded, horizontal
Need: 2 pieces for each cut
for the connection of cable trays and the fittings H80, with splice plates H80should be clipped on both cable trays sides.
KPGH 80
7032 69K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955718
Weight 100 units
22,5
During the assembly, an expansion gap of 3 mm for dilatation must be considered.
Separatorpultruded
The divider KPT80 is delivered not mounted, it can be fixed in the cable tray with a bolt M 6x16V4A each meter.The divider KPT80/M can be delivered pre-mounted (riveted ), the position inside the cabletray must be defined in the purchase order.
to separate cables with different functions and / or to separate voltages
KPT 80
7032 65KPT 80/M 7032 65
K23
K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m3 m
EANcode
953134953158
Weight 100 units
m
4242
GRP tee junction for cable tray, large radiuspressed, with interlocking coupler
KPST 80.100/P
7032 80 100KPST 80.150/P 7032 80 150KPST 80.200/P 7032 80 200KPST 80.300/P 7032 80 300
K23
K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
954759967629954766954773
Weight 100 units
pc
78,078,090,0
108,5
During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.
GRP elbow 45°, small radiuspressed, with interlocking coupler
The piece is provided with a sleeve riveted on one side only.
KPC 80.100/P
7032 80 100 100KPC 80.150/P 7032 80 150 175KPC 80.200/P 7032 80 200 200KPC 80.300/P 7032 80 300 225
K23
K23K23K23
Item ref. RAL colour
Height WidthB
Radius R
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
953615967636953622953639
Weight 100 units
pc
22324585
During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
64
CABLE TRAY SYSTEM KP
GRP elbow 90°, large radiuspressed, with interlocking coupler
KPB 80.100/P
7032 80 100 125 100KPB 80.150/P 7032 80 150 200 175KPB 80.200/P 7032 80 200 225 200KPB 80.300/P 7032 80 300 250 225
K23
K23K23K23
Item ref. RAL colour
Height WidthB
C Radius R
mm mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
953370967643953387953394
Weight 100 units
pc/
41,565,090,0
170,0
During the assembly, every fitting must be supported at each end, and also in the center.To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
GRP changing elevationpressed, in 2 pieces, with interlocking coupler
Composed with different pieces, the changing elevation can be mounted in different heights
KPET 80.100/P
7032 80 100 160 480 800KPET 80.150/P 7032 80 150 160 480 800KPET 80.200/P 7032 80 200 160 480 800KPET 80.300/P 7032 80 300 160 480 800
K23
K23K23K23
Item ref. RAL colour
Height WidthB
HeightH1
HeightH2
HeightH3
mm mm mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
954544967650954551954568
Weight 100 units
pc/
190230270350
During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.The part height depends on the height and the configuration usedH1 = 160 mm =>L1 = 785 mm ( a cut is necessary )H2 = 480 mm =>L2 = 1100 mmH3 = 800 mm =>L3 = 970 mm
GRP vertical inside elbowpressed, with interlocking coupler
KPBI 80.100/P
7032 80 100KPBI 80.150/P 7032 80 150KPBI 80.200/P 7032 80 200KPBI 80.300/P 7032 80 300
K23
K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
954308967667954315954322
Weight 100 units
pc
506580
102
During the assembly, every fitting must be supported at each end, and also in the center. To ensure a correct installation, the couplers must be fixed laterally by 4 bolts M6x16 V4A on eachtray end.
GRP vertical outside elbowpressed, with interlocking coupler
KPBA 80.100/P
7032 80 100KPBA 80.150/P 7032 80 150KPBA 80.200/P 7032 80 200KPBA 80.300/P 7032 80 300
K23
K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
954247967674954254954261
Weight 100 units
pc
40506080
During the assembly, every fitting must be supported at each end, at the cable entry. To ensure a correct installation, the couplers must be fixed laterally by 2 bolts M6x16 V4A on eachtray end.
65
NOTES
66
CABLE TRAY SYSTEM COVERS KP
GRP cover for cable traypultruded
for cable trays
Used for: GRP cable trays H40, H50 and H80 KP… and KPL… (perforated)
KPD 60
7032 60 2,0KPD 100 7032 100 2,5KPD 150 7032 150 2,5KPD 200 7032 200 2,5KPD 300 7032 300 2,5
K23
K23K23K23K23
Item ref. RAL colour
WidthB
Materialthickness
(th)mm mm
Min. pack.
3 m3 m3 m3 m3 m
EANcode
956241956258956265956272956289
Weight 100 units
pc m/
29,152,075,0
100,0145,0
To ensure a correct and strong installation of the cable trays and covers , a minimum distance of3 mm for dilatation must be considered for both parts. Fast fix clip of covers. In extreme windy conditions (strong winds, storms for example), werecommend to add cover clips DF…V4A.
GRP cover for horizontal elbow 45°, small radiuspressed
Used for: Elbow 45° H50, H80 and H110 mm, KKC… and KPC…/P
KKCD 100
7032 100KKCD 150 7032 150KKCD 200 7032 200KKCD 250 7032 250KKCD 300 7032 300KKCD 400 7032 400KKCD 500 7032 500KKCD 600 7032 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956456956463956470956487956494956500956517956524
Weight 100 units
pc
1223335051
138150173
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
Cover for horizontal elbow 90°, large radiuspressed
Used for: Horizontal elbow 90°, large radius, H50, H80 and H110, KKB… and KPB…/P
KKBD 100
7032 100KKBD 150 7032 150KKBD 200 7032 200KKBD 250 7032 250KKBD 300 7032 300KKBD 400 7032 400KKBD 500 7032 500KKBD 600 7032 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956371956388956395956401956418956425956432956449
Weight 100 units
pc
19,543,068,097,0
115,0241,0334,0403,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for vertical inside elbowpressed
Used for: Vertical inside elbow 50 mm high, KKBI… and KPBI…/P
KKBID 50.050
7032 50 50KKBID 50.100 7032 50 100KKBID 50.150 7032 50 150KKBID 50.200 7032 50 200KKBID 50.300 7032 50 300
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
956814956821956838956845956852
Weight 100 units
pc
520425063
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
67
GRP cover for vertical inside elbowpressed
Used for: Vertical inside elbow 80 mm high, KKBI… and KPBI…/P
KKBID 80.100
7032 80 100KKBID 80.150 7032 80 150KKBID 80.200 7032 80 200KKBID 80.250 7032 80 250KKBID 80.300 7032 80 300KKBID 80.400 7032 80 400KKBID 80.500 7032 80 500KKBID 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956869956876956883956890956906956913956920956937
Weight 100 units
pc
18,024,533,040,045,561,073,095,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for vertical outside elbowpressed
Used for: Vertical outside elbow H50 mm, KKBA… and KPBA…/P
KKBAD 50.050
7032 50 50KKBAD 50.100 7032 50 100KKBAD 50.150 7032 50 150KKBAD 50.200 7032 50 200KKBAD 50.300 7032 50 300
K23
K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
956623956630956647956654956661
Weight 100 units
pc
7,810,042,051,065,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for vertical outside elbowpressed
Used for: Vertical outside elbow H80 mm, KKBA… and KPBA…/P
KKBAD 80.100
7032 80 100KKBAD 80.150 7032 80 150KKBAD 80.200 7032 80 200KKBAD 80.250 7032 80 250KKBAD 80.300 7032 80 300KKBAD 80.400 7032 80 400KKBAD 80.500 7032 80 500KKBAD 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
956678956685956692956708956715956722956739956746
Weight 100 units
pc
29,539,051,061,072,090,0
120,0136,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for changing elevationpressed
1 KKETD is composed of :- 1 GRP cover for inside elbow- 1 GRP cover for outside elbowUsed for: Changing elevation H50 mm KKET… and KPET…/P
KKETD 50.100
7032 50 100KKETD 50.150 7032 50 150KKETD 50.200 7032 50 200KKETD 50.300 7032 50 300
K23
K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.
EANcode
957002957019957026957033
Weight 100 units
pc
20414060
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
68
CABLE TRAY SYSTEM COVERS KP
GRP cover for changing elevationpressed
1 KKETD is composed of :- 1 GRP cover for inside elbow- 1 GRP cover for outside elbowUsed for: Changing elevation H50 mm KKET… and KPET…/P
KKETD 80.100
7032 80 100KKETD 80.150 7032 80 150KKETD 80.200 7032 80 200KKETD 80.250 7032 80 250KKETD 80.300 7032 80 300KKETD 80.400 7032 80 400KKETD 80.500 7032 80 500KKETD 80.600 7032 80 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957040957057957064957071957088957095957101957118
Weight 100 units
pc
23,531,740,544,047,061,098,0
120,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for tee junction, large radiuspressed, with interlocking coupler
Used for: Cover for tee junction for H50, H80 and H110 mm, KKST… and KPST…/P
KKSTD 100
7032 100KKSTD 150 7032 150KKSTD 200 7032 200KKSTD 250 7032 250KKSTD 300 7032 300KKSTD 400 7032 400KKSTD 500 7032 500KKSTD 600 7032 600
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957187957194957200957217957224957231957248957255
Weight 100 units
pc
354252636578
100118
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
Tee junction cover, small radiuspressed, with interlocking coupler
Used for: Tee junction for H50 and H80 mm, KKSS… and KPSS…/P
KKSSD 50
7032 50KKSSD 100 7032 100KKSSD 150 7032 150KKSSD 200 7032 200KKSSD 250 7032 250KKSSD 300 7032 300
K23
K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957262957279957286957293957309957316
Weight 100 units
pc
5,08,09,5
13,014,515,5
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for right hand reductionpressed
Used for: Right hand reduction H50, H80 and H110 mm, KKRR…
KKRRD 200
7032 200KKRRD 300 7032 300KKRRD 400 7032 400KKRRD 500 7032 500KKRRD 600 7032 600
K23
K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
957378957385957392957408957415
Weight 100 units
pc
50,579,0
119,0131,0160,0
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
69
GRP cover for left hand reductionpressed
Used for: Reduction H50, 80 and 110 mm, KKRL…
KKRLD 200
7032 200KKRLD 300 7032 300KKRLD 400 7032 400KKRLD 500 7032 500KKRLD 600 7032 600
K23
K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
957323957330957347957354957361
Weight 100 units
pc
4975
110147160
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
Cover fixing clipstainless steel
for fixing the cables tray covers and fittings
Used for: Cable tray cover KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... and KKRRD...
DF 50 E4
55DF 80 E4 85
E4
E4
Item ref. Height
mm
Min. pack.
50 p.50 p.
EANcode
957873957880
Weight 100 units
pc.
1,72,1
Under normal conditions, it is recommended to mount 1 clip each meter alternatively every 3 meters.Under extreme weather conditions, such as strong winds or storms, the quantity of clips must beincreased.
Cover fixing
Used for: Cover for cable tray KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... und KKRRD…
DF M
K01
Item ref. Min. pack.
50 p.
EANcode
957927
Weight 100 units
pc.
0,2
For fixing the cover, it is necessary to drill a 8,2 mm diameter hole for the diameter. In extremeweather conditions such as strong winds, for example, the quantity of clips must be increased.
Cover fixing
Used for: Cover for cable tray KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... und KKRRD…
DFUB 5.5X19 E4
N E4
Item ref. Min. pack.
50 p.
EANcode
062065
Weight 100 units
0,64
For fixing the cover, it is necessary to drill a 8,2 mm diameter hole for the diameter. In extremeweather conditions such as strong winds, for example, the quantity of clips must be increased.
70
CABLE TRAY SYSTEM ACCESSOIRES KP
Rack for cablespressed, standard
The rack for cables KR is delivered not mounted and must be screwed on the cable tray basewith 2 bolts M…V4A at each meter.The rack for cables KR…/M can be delivered pre-mounted (riveted), the position must bedefined in the purchase order.
for fixing the cables with cable ties in the vertical rack
Used for: Cable tray H50, H80 and H110 mm, KK…, KKL…, KP…, KPL…
The mounting straps must be ordered separately
KR 100
7032 100KR 150 7032 150KR 200 7032 200KR 250 7032 250KR 300 7032 300KR 400 7032 400KR 500 7032 500KR 600 7032 600KR 100/M 7032 100KR 150/M 7032 150KR 200/M 7032 200KR 250/M 7032 250KR 300/M 7032 300KR 400/M 7032 400KR 500/M 7032 500KR 600/M 7032 600
K23
K23K23K23K23K23K23K23K23K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
955466955473955480955497955503955510955527955534955541955558955565955572955589955596955602955619
Weight 100 units
pc
2,43,14,06,06,7
11,016,020,02,43,14,06,06,7
11,016,020,0
For a wall or ceiling mounting, the cable tray supports must be adjusted properly in order to obtain allcable trays on a straight line.
Separating studpultruded
Not suitable when the cable tray is mounted vertically (not horizontally)
for an easy mounting of cables and connections
TB
K01
Item ref. Min. pack.
1 p.
EANcode
957934
Weight 100 units
m
1
When mounting the separating stud, it is necesary to drill a 10 mm hole diameter in the base.
Dome head boltIncluded nut and washer
Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4
FKM 6X16 E4
6 16FKM 6X20 E4 6 20
E4
E4
Item ref. ThreadM
LengthL
mm
Min. pack.
100 p.100 p.
EANcode
962693962709
Weight 100 units
pc
1,21,4
Dome head boltIncluded nut and washer
Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4
FKM 8X20 K01
8 20K01
Item ref. ThreadM
LengthL
mm
Min. pack.
100 p.
EANcode
962716
Weight 100 units
pc
0,4
Hexagon head boltIncluded nut and washer
Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4
SKM 10X30 E4
10 30SKM 10X40 E4 10 40
E4
E4
Item ref. ThreadM
LengthL
mm
Min. pack.
100 p.100 p.
EANcode
962730962747
Weight 100 units
pc
4,55,1
70
ACCESSOIRES POUR SYSTÈME DE CHEMINS DE CÂBLES KP
Ratelier pour câblespressé, standard
Le râteau pour câbles KR est livré non-monté et à visser dans le fond du socle à l'aide de 2boulons M...V4A par mètre.Le râteau pour câbles KR.../M peut être pré-monté en usine (riveté), le positionnement est àdéfinir au moment de la commande.
pour la fixation des câbles à l'aide de colliers dans le ratelier vertical
Utilisable pour : Chemins de câbles H50,H80 et H110 mm, KK..., KKL..., KP..., KPL...
Les colliers de fixation doivent être commandés séparément
KR 100
7032 100KR 150 7032 150KR 200 7032 200KR 250 7032 250KR 300 7032 300KR 400 7032 400KR 500 7032 500KR 600 7032 600KR 100/M 7032 100KR 150/M 7032 150KR 200/M 7032 200KR 250/M 7032 250KR 300/M 7032 300KR 400/M 7032 400KR 500/M 7032 500KR 600/M 7032 600
K23
K23K23K23K23K23K23K23K23K23K23K23K23K23K23K23
Réf. Art. Cou-leurRAL
LargeurB
mm
Coli-sage mini.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
CodeEAN
955466955473955480955497955503955510955527955534955541955558955565955572955589955596955602955619
Poids100uni.
pc
kg
2,43,14,06,06,7
11,016,020,02,43,14,06,06,7
11,016,020,0
En cas de montage mural ou au plafond, il faut prendre soin de poser correctement le chemin decâbles sur son support afin de former une surface plane
Tige de séparationpultrudée
Non adapté lorsque le chemin de câbles est monté à champ.
pour le montage facile de câbles et de liaisons
TB
K01
Réf. Art. Coli-sage mini.
1 p.
CodeEAN
957934
Poids100uni.
m
kg
1
Lors du montage, il est nécessaire de percer un trou traversant de diametre 10 mm pour l'installationdes tiges de séparation.
Bouloninclus écrou et rondelle
Egalement appelé : M6x16V4A pour FKM 6x16 E4, M6x20V4A pour FKM 6x20 E4, M8x20PA6pour FKM 8x20 K01, M10x30V4A pour SKM 10x30 E4
FKM 6X16 E4
6 16FKM 6X20 E4 6 20
E4
E4
Réf. Art. FiletageM
Long.L
mm
Coli-sage mini.
100 p.100 p.
CodeEAN
962693962709
Poids100uni.
pc
kg
1,21,4
Bouloninclus écrou et rondelle
Egalement appelé : M6x16V4A pour FKM 6x16 E4, M6x20V4A pour FKM 6x20 E4, M8x20PA6pour FKM 8x20 K01, M10x30V4A pour SKM 10x30 E4
FKM 8X20 K01
8 20K01
Réf. Art. FiletageM
Long.L
mm
Coli-sage mini.
100 p.
CodeEAN
962716
Poids100uni.
pc
kg
0,4
71
NOTES
Cable ladder
Divider
Fittings
Covers
Accessoires
ULULULULCable ladder systems available in height 53 80 100 150
ULSystemSystem
ULULULULUL72
CABLE TRAY SYSTEM GFK
To support important quantities of cables with large diameter, EBO Systems propose the cable ladder in Glass
Reinforced polyester GRP, with a support distance of up 6 m. The EBO Systems cable ladder allows to meet
the needs in the industry such as nuclear and thermal power plants but also in the oil and gas industry.
The unique patented clip-in rungs assembly, without metallic or thermoplastic parts who weak the cables ladders,
the cable ladder EBO Systems is the only one 100% GRP and could be easly assembled close to customers.
73
GRP-Cable Ladder, pultruded UL 76 80 84 89
GRP-Endcap, pressed ULKE 76 80 84 89
GRP-Splice plate, horizontal ULGH 76 80 85 90
Stainless steel-Splice plate, horizontal ULIH 77 81 85 90
GRP-Divider, pressed ULTL 77 81 85 90
GRP-T-, pultruded ULTE 77 81 85 90
GRP-Cross, pultruded ULX 77 81 86 91
GRP-Elbow 90°, pultruded ULB 78 82 86 91
GRP-Elbow, pultruded, vertical ULBA 78 82 87 92
GRP-Reducers, pultruded ULRU 78 82 87 92
GRP-Splice plate, pressed, vertical ULGV 79 83 87 92
Stainless steel-Splice plate, vertical ULIV 79 83 88 93
Cover clips DF 96
Vertical clamp ULKV 96
Cover fi x DFUB 97*
Cover clamp DFW 97
GRP-Hold down clamp ULKG 98* Hold down clamp ULKH 98*
Bolt BKM 98*
Dome head bolt FKM 98*
Hexagon head bolt SKM 98*
Cover fi xing insert DF M 99*
Vertical clamp WWU 99*
Fork-type self-locking plier ULP 99*
Covers for cables ladders UL systems are available from page 94.
SYSTEM
ACCESSORIES
Available siderail heights 53 80 100 150
53
53
53
53
53
53
53
53
53
53
53
53
80
80
80
100
80
80
80
80
80
80
80
80
80
100
100
150
150
150
100 150
100 150
100 150
100 150
100 150
100 150
100 150
100 150
100 150
* suitable for all heights
NEW
74
CABLE LADDER SYSTEM UL
UL...
ULKE...
ULRU...
ULB...
ULBA...
KKD...
ULTE...
ULBA...
ULX...
75
76
CABLE LADDER SYSTEM UL
GRP cable ladderspultruded, not perforated rungs
L = fixing distance (m)
Load
q (k
N/m
)
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5 from thesupport. If this distance is not respected, it is necessary to raise the deflection values by approx. 30%.
The cables ladders have the advantage to be 100% GRP (Glass Reinforced Polyester ), thanksto unique patented clip-in rungs assembly, without metallic or thermoplastic parts.The cables ladders are delivered with non perforated rungs. However the option of perforatedrungs is still possible, please contact us.
Load diagram : q = load evenly distributed cables (according to DIN EN IEC 61537 standard)
UL 53.150/3
7032 53 150 4 6,5 x 20UL 53.200/3 7032 53 200 4 6,5 x 20UL 53.300/3 7032 53 300 4 6,5 x 20UL 53.400/3 7032 53 400 4 6,5 x 20UL 53.500/3 7032 53 500 4 6,5 x 20UL 53.600/3 7032 53 600 4 6,5 x 20UL 53.200 7032 53 200 4 6,5 x 20UL 53.300 7032 53 300 4 6,5 x 20UL 53.400 7032 53 400 4 6,5 x 20UL 53.500 7032 53 500 4 6,5 x 20UL 53.600 7032 53 600 4 6,5 x 20
K23
K23K23K23K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Materialthickness
(th)
Side perforations
mm mm mm mm
Min. pack.
3 m3 m3 m3 m3 m3 m6 m6 m6 m6 m6 m
EANcode
957958957972957996958016958030958054957965957989958009958023958047
Weight 100 units
m
108,7116,0131,0145,0160,0175,0116,0131,0145,0160,0175,0
End cap for GRP cable ladderpultruded
Used for: Cable ladders UL…H53 L3 and UL…H53 L6
Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
ULKE 53.150
7032 53 150ULKE 53.200 7032 53 200ULKE 53.300 7032 53 300ULKE 53.400 7032 53 400ULKE 53.500 7032 53 500ULKE 53.600 7032 53 600
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
965748965755965762965779965786965793
Weight 100 units
pc
5,67,09,8
12,615,418,2
GRP horizontal splice platepressed, horizontal
Need: 2 pieces for each cut, to be ordered separatly
for connecting cable ladders and fittings H…, with splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULGH 53
7032 45 190K23
Item ref. RAL colour
Height LengthL
mm mm
Min. pack.
1 set
EANcode
960156
Weight 100 units
8,5
When fixing the splice plates ULIH… and ULGH..., an expansion distance of about 3 mm must beconsidered.
77
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H53
ULIH 53 E4
45 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960194
Weight 100 units
6,1
Mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 53
7032 30K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958511
Weight 100 units
m
60
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULTE 53.150
7032 53 150ULTE 53.200 7032 53 200ULTE 53.300 7032 53 300ULTE 53.400 7032 53 400ULTE 53.500 7032 53 500ULTE 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959235959242959259959266959273959280
Weight 100 units
pc
550590620720760830
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULX 53.150
7032 53 150 —ULX 53.200 7032 53 200 —ULX 53.300 7032 53 300 —ULX 53.400 7032 53 400 —ULX 53.500 7032 53 500 —ULX 53.600 7032 53 600 —
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
B+D
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959570959587959594959600959617959624
Weight 100 units
pc
687,5738,0775,0900,0950,0
1.050,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
77
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H53
ULIH 53 E4
45 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960194
Weight 100 units
6,1
Mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 53
7032 30K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958511
Weight 100 units
m
60
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULTE 53.150
7032 53 150ULTE 53.200 7032 53 200ULTE 53.300 7032 53 300ULTE 53.400 7032 53 400ULTE 53.500 7032 53 500ULTE 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959235959242959259959266959273959280
Weight 100 units
pc
550590620720760830
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULX 53.150
7032 53 150 —ULX 53.200 7032 53 200 —ULX 53.300 7032 53 300 —ULX 53.400 7032 53 400 —ULX 53.500 7032 53 500 —ULX 53.600 7032 53 600 —
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
B+D
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959570959587959594959600959617959624
Weight 100 units
pc
687,5738,0775,0900,0950,0
1.050,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
77
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H53
ULIH 53 E4
45 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960194
Weight 100 units
6,1
Mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 53
7032 30K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958511
Weight 100 units
m
60
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULTE 53.150
7032 53 150ULTE 53.200 7032 53 200ULTE 53.300 7032 53 300ULTE 53.400 7032 53 400ULTE 53.500 7032 53 500ULTE 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959235959242959259959266959273959280
Weight 100 units
pc
550590620720760830
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULX 53.150
7032 53 150 —ULX 53.200 7032 53 200 —ULX 53.300 7032 53 300 —ULX 53.400 7032 53 400 —ULX 53.500 7032 53 500 —ULX 53.600 7032 53 600 —
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
B+D
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959570959587959594959600959617959624
Weight 100 units
pc
687,5738,0775,0900,0950,0
1.050,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
77
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H53
ULIH 53 E4
45 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960194
Weight 100 units
6,1
Mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 53
7032 30K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958511
Weight 100 units
m
60
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULTE 53.150
7032 53 150ULTE 53.200 7032 53 200ULTE 53.300 7032 53 300ULTE 53.400 7032 53 400ULTE 53.500 7032 53 500ULTE 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959235959242959259959266959273959280
Weight 100 units
pc
550590620720760830
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULX 53.150
7032 53 150 —ULX 53.200 7032 53 200 —ULX 53.300 7032 53 300 —ULX 53.400 7032 53 400 —ULX 53.500 7032 53 500 —ULX 53.600 7032 53 600 —
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
B+D
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959570959587959594959600959617959624
Weight 100 units
pc
687,5738,0775,0900,0950,0
1.050,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
78
CABLE LADDER SYSTEM UL
GRP elbow 90°pultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
Available in radius 250 mm
ULB 53.150
7032 53 150ULB 53.200 7032 53 200ULB 53.300 7032 53 300ULB 53.400 7032 53 400ULB 53.500 7032 53 500ULB 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
958559958566958573958580958597958603
Weight 100 units
pc
160180200270310350
During the installation, you must take care to position a support under the elbow at each cable ladderend. If the bending radius is higher than 250 mm and if the width of cable ladder is higher than 400 mm, anadditional intermediary support is then necessary. The metallic splice plates must be fixed at each cable ladder end with 4 bolts M 6x20 V4A (to beordered separately).
GRP adjustable elbowpultruded, with integrated splice plates, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
ULBA 53.150
7032 53 150ULBA 53.200 7032 53 200ULBA 53.300 7032 53 300ULBA 53.400 7032 53 400ULBA 53.500 7032 53 500ULBA 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
958894958900958917958924958931958948
Weight 100 units
pc
8082869195
100
In order to guarantee a conform assembly, the metallic splice plates must be fixed at each cableladder end with 4 bolts M 6 x16 V4A and the composite splice plates must be fixed at each cableladder end with 4 bolts M 6 x 20 V4A (to be ordered separatelyIf the bending radius is higher than 250 mm and if the width of cable ladder is higher than 400 mm, anadditional intermediary support is then necessary.
Reducerpultruded
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering. The dimensions B1 and B2 allow to define the reduction size to use
to reduce or increase the cables ladder width
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULRU 53.100
7032 53 100ULRU 53.150 7032 53 150ULRU 53.200 7032 53 200ULRU 53.300 7032 53 300ULRU 53.400 7032 53 400
E4 K23
E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
959914959921959938959945959952
Weight 100 units
pc
3337435064
When mounting, the reducer must be supported by a bracket. The dimension B corresponds to thereduction. To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
79
GRP vertical adjustable or vertical fixed angle splice platepressed, vertical
Need: 2 pieces for each cut, to be ordered separatly
for connecting cable ladders and fittings H80, with adjustable or fixed splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULGV 53
7032 45K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
960231
Weight 100 units
27,5
Vertical splice platevertical, stainless steel
Need: 2 pieces for each cut, to be ordered separatly
for connecting cable ladders and fittings H53, with adjustable splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULIV 53 E4
45E4
Item ref. Height
mm
Min. pack.
1 set
EANcode
960279
Weight 100 units
30
80
CABLE LADDER SYSTEM UL
GRP cable ladderspultruded, not perforated rungs
L = fixing distance (m)
Load
q (k
N/m
)
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5 from thesupport. If this distance is not respected, it is necessary to raise the deflection values by approx. 30%.
The cables ladders have the advantage to be 100% GRP (Glass Reinforced Polyester ), thanksto unique patented clip-in rungs assembly, without metallic or thermoplastic parts.The cables ladders are delivered with non perforated rungs. However the option of perforatedrungs is still possible, please contact us.
Load diagram : q = load evenly distributed cables (according to DIN EN IEC 61537 standard)
UL 80.150/3
7032 80 150 4UL 80.200/3 7032 80 200 4UL 80.300/3 7032 80 300 4UL 80.400/3 7032 80 400 4UL 80.500/3 7032 80 500 4UL 80.600/3 7032 80 600 4UL 80.150 7032 80 150 4UL 80.200 7032 80 200 4UL 80.300 7032 80 300 4UL 80.400 7032 80 400 4UL 80.500 7032 80 500 4UL 80.600 7032 80 600 4
K23
K23K23K23K23K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Materialthickness
(th)mm mm mm
Min. pack.
3 m3 m3 m3 m3 m3 m6 m6 m6 m6 m6 m6 m
EANcode
958078958092958115958139958153958177958061958085958108958122958146958160
Weight 100 units
m
223230245260275290223230245260275290
End cap for GRP cable ladderpultruded
Used for: Cable ladders UL…H80 L3 and UL…H80 L6
Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
ULKE 80.150
7032 80 150ULKE 80.200 7032 80 200ULKE 80.300 7032 80 300ULKE 80.400 7032 80 400ULKE 80.500 7032 80 500ULKE 80.600 7032 80 600
K23
K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
965809965816965823965830965847965854
Weight 100 units
pc
8,510,614,819,123,327,6
GRP horizontal splice platepressed, horizontal
for connecting cable ladders and fittings H…, with splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULGH 80
7032 72 200K23
Item ref. RAL colour
Height LengthL
mm mm
Min. pack.
1 set
EANcode
960163
Weight 100 units
10
When fixing the splice plates ULIH… and ULGH..., an expansion distance of about 3 mm must beconsidered.
81
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H80
ULIH 80 E4
72 20x8 Ø 8E4
Item ref. Height For oblong perforations LL
perforation
mm mm mm
Min. pack.
1 set
EANcode
960200
Weight 100 units
6,1
mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 80
7032 57K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958528
Weight 100 units
m
60
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 80/ ULIH 80 V4A are not included in the cables ladders, please order themseparately.
ULTE 80.150
7032 80 150ULTE 80.200 7032 80 200ULTE 80.300 7032 80 300ULTE 80.400 7032 80 400ULTE 80.500 7032 80 500ULTE 80.600 7032 80 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959297959303959310959327959334959341
Weight 100 units
pc
550590653720780850
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 80/ ULIH 80 V4A are not included in the cables ladders, please order themseparately.
ULX 80.150
7032 80 150ULX 80.200 7032 80 200ULX 80.300 7032 80 300ULX 80.400 7032 80 400ULX 80.500 7032 80 500ULX 80.600 7032 80 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959631959648959655959662959679959686
Weight 100 units
pc
687,5738,0816,0900,0975,0820,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mm
77
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H53
ULIH 53 E4
45 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960194
Weight 100 units
6,1
Mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 53
7032 30K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958511
Weight 100 units
m
60
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULTE 53.150
7032 53 150ULTE 53.200 7032 53 200ULTE 53.300 7032 53 300ULTE 53.400 7032 53 400ULTE 53.500 7032 53 500ULTE 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959235959242959259959266959273959280
Weight 100 units
pc
550590620720760830
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULX 53.150
7032 53 150 —ULX 53.200 7032 53 200 —ULX 53.300 7032 53 300 —ULX 53.400 7032 53 400 —ULX 53.500 7032 53 500 —ULX 53.600 7032 53 600 —
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
B+D
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959570959587959594959600959617959624
Weight 100 units
pc
687,5738,0775,0900,0950,0
1.050,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
77
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H53
ULIH 53 E4
45 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960194
Weight 100 units
6,1
Mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 53
7032 30K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958511
Weight 100 units
m
60
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULTE 53.150
7032 53 150ULTE 53.200 7032 53 200ULTE 53.300 7032 53 300ULTE 53.400 7032 53 400ULTE 53.500 7032 53 500ULTE 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959235959242959259959266959273959280
Weight 100 units
pc
550590620720760830
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULX 53.150
7032 53 150 —ULX 53.200 7032 53 200 —ULX 53.300 7032 53 300 —ULX 53.400 7032 53 400 —ULX 53.500 7032 53 500 —ULX 53.600 7032 53 600 —
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
B+D
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959570959587959594959600959617959624
Weight 100 units
pc
687,5738,0775,0900,0950,0
1.050,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
77
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H53
ULIH 53 E4
45 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960194
Weight 100 units
6,1
Mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 53
7032 30K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958511
Weight 100 units
m
60
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULTE 53.150
7032 53 150ULTE 53.200 7032 53 200ULTE 53.300 7032 53 300ULTE 53.400 7032 53 400ULTE 53.500 7032 53 500ULTE 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959235959242959259959266959273959280
Weight 100 units
pc
550590620720760830
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULX 53.150
7032 53 150 —ULX 53.200 7032 53 200 —ULX 53.300 7032 53 300 —ULX 53.400 7032 53 400 —ULX 53.500 7032 53 500 —ULX 53.600 7032 53 600 —
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
B+D
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959570959587959594959600959617959624
Weight 100 units
pc
687,5738,0775,0900,0950,0
1.050,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
82
CABLE LADDER SYSTEM UL
GRP elbow 90°pultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 80/ ULIH 80 V4A are not included in the cables ladders, please order themseparately.
ULB 80.150
7032 80 150ULB 80.200 7032 80 200ULB 80.300 7032 80 300ULB 80.400 7032 80 400ULB 80.500 7032 80 500ULB 80.600 7032 80 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
958610958627958634958641958658958665
Weight 100 units
pc
220240270360400440
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP adjustable elbowpultruded, with integrated splice plates, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
ULBA 80.150
7032 80 150ULBA 80.200 7032 80 200ULBA 80.300 7032 80 300ULBA 80.400 7032 80 400ULBA 80.500 7032 80 500ULBA 80.600 7032 80 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
958955958962958979958986958993959006
Weight 100 units
pc
130136144150155161
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
Reducerpultruded
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering. The dimensions B1 and B2 allow to define the reduction size to use
to reduce or increase the cables ladder width
The splice plates ULGH 80/ ULIH 80 V4A are not included in the cables ladders, please order themseparately.
ULRU 80.100
7032 80 100ULRU 80.150 7032 80 150ULRU 80.200 7032 80 200ULRU 80.300 7032 80 300ULRU 80.400 7032 80 400
E4 K23
E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
959969959976959983959990960002
Weight 100 units
pc
4246516371
When mounting, the reducer must be supported by a bracket. The dimension B corresponds to thereduction. To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
83
GRP vertical adjustable or vertical fixed angle splice platepressed, vertical
Need: 2 pieces for each cut, to be ordered separatly
for connecting cable ladders and fittings H80, with adjustable or fixed splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULGV 80
7032 72K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
960248
Weight 100 units
27,5
Vertical splice platevertical, stainless steel
Need: 2 pieces for each cut, to be ordered separatly
for connecting cable ladders and fittings H80, with adjustable splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULIV 80 E4
72E4
Item ref. Height
mm
Min. pack.
1 set
EANcode
960286
Weight 100 units
30
84
CABLE LADDER SYSTEM UL
GRP cable ladderspultruded, not perforated rungs
L = fixing distance (m)
Load
q (k
N/m
)
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5 from thesupport. If this distance is not respected, it is necessary to raise the deflection values by approx. 30%.
The cables ladders have the advantage to be 100% GRP (Glass Reinforced Polyester ), thanksto unique patented clip-in rungs assembly, without metallic or thermoplastic parts.The cables ladders are delivered with non perforated rungs. However the option of perforatedrungs is still possible, please contact us.
Load diagram : q = load evenly distributed cables (according to DIN EN IEC 61537 standard)
UL 100.150/3
7032 100 150 5UL 100.200/3 7032 100 200 5UL 100.300/3 7032 100 300 5UL 100.400/3 7032 100 400 5UL 100.450/3 7032 100 450 5UL 100.500/3 7032 100 500 5UL 100.600/3 7032 100 600 5UL 100.750/3 7032 100 750 5UL 100.900/3 7032 100 900 5UL 100.150 7032 100 150 5UL 100.200 7032 100 200 5UL 100.300 7032 100 300 5UL 100.400 7032 100 400 5UL 100.450 7032 100 450 5UL 100.500 7032 100 500 5UL 100.600 7032 100 600 5UL 100.750 7032 100 750 5UL 100.900 7032 100 900 5
K23
K23K23K23K23K23K23K23K23K23K23K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Materialthickness
(th)mm mm mm
Min. pack.
3 m3 m3 m3 m3 m3 m3 m3 m3 m6 m6 m6 m6 m6 m6 m6 m6 m6 m
EANcode
958191958214958238958252958276958290958313958351958399958184958207958221958245958269958283958306958344958382
Weight 100 units
m
312,3320,8338,6356,3362,0375,0392,5413,5445,1312,3320,8338,6356,3362,0375,0392,5413,5445,1
End cap for GRP cable ladderpultruded
Used for: Cable ladders UL…H100 L3 and UL…H100 L6
Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
ULKE 100.150
7032 100 150ULKE 100.200 7032 100 200ULKE 100.300 7032 100 300ULKE 100.400 7032 100 400ULKE 100.450 7032 100 450ULKE 100.500 7032 100 500ULKE 100.600 7032 100 600ULKE 100.700 7032 100 700ULKE 100.750 7032 100 750ULKE 100.800 7032 100 800ULKE 100.900 7032 100 900
K23
K23K23K23K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
965526965533965540965557965564965571965588965595965601965618965625
Weight 100 units
pc
1620273542454957606470
85
GRP horizontal splice platepressed, horizontal
for connecting cable ladders and fittings H…, with splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULGH 100
7032 90 200K23
Item ref. RAL colour
Height LengthL
mm mm
Min. pack.
1 set
EANcode
960170
Weight 100 units
3,5
When fixing the splice plates ULIH… and ULGH..., an expansion distance of about 3 mm must beconsidered.
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H100
ULIH 100 E4
90 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960217
Weight 100 units
19,5
mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 100
7032 65K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958535
Weight 100 units
pc
40
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 100/ ULIH 100 V4A are not included in the cables ladders, please order themseparately.
Available in radius 250 mm, 600 mm und 900 mm
ULTE 100.150
7032 100 150ULTE 100.200 7032 100 200ULTE 100.300 7032 100 300ULTE 100.400 7032 100 400ULTE 100.450 7032 100 450ULTE 100.500 7032 100 500ULTE 100.600 7032 100 600ULTE 100.750 7032 100 750ULTE 100.900 7032 100 900
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959358959365959372959389959396959402959419959433959457
Weight 100 units
pc
520550653720750780850950
1050
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
77
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H53
ULIH 53 E4
45 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960194
Weight 100 units
6,1
Mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 53
7032 30K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958511
Weight 100 units
m
60
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULTE 53.150
7032 53 150ULTE 53.200 7032 53 200ULTE 53.300 7032 53 300ULTE 53.400 7032 53 400ULTE 53.500 7032 53 500ULTE 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959235959242959259959266959273959280
Weight 100 units
pc
550590620720760830
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULX 53.150
7032 53 150 —ULX 53.200 7032 53 200 —ULX 53.300 7032 53 300 —ULX 53.400 7032 53 400 —ULX 53.500 7032 53 500 —ULX 53.600 7032 53 600 —
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
B+D
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959570959587959594959600959617959624
Weight 100 units
pc
687,5738,0775,0900,0950,0
1.050,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
86
CABLE LADDER SYSTEM UL
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 100/ ULIH 100 V4A are not included in the cables ladders, please order themseparately.
Available in radius 250 mm, 600 mm und 900 mm
ULX 100.150
7032 100 150ULX 100.200 7032 100 200ULX 100.300 7032 100 300ULX 100.400 7032 100 400ULX 100.450 7032 100 450ULX 100.500 7032 100 500ULX 100.600 7032 100 600ULX 100.750 7032 100 750ULX 100.900 7032 100 900
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959693959709959716959723959730959747959754959778959792
Weight 100 units
pc
710750816900940975
107011801300
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP elbow 90°pultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 100/ ULIH 100 V4A are not included in the cables ladders, please order themseparately.
Available in radius 250 mm, 600 mm und 900 mm
ULB 100.150
7032 100 150ULB 100.200 7032 100 200ULB 100.300 7032 100 300ULB 100.400 7032 100 400ULB 100.450 7032 100 450ULB 100.500 7032 100 500ULB 100.600 7032 100 600ULB 100.750 7032 100 750ULB 100.900 7032 100 900
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
958672958689958696958702958719958726958733958757958771
Weight 100 units
pc m/
320340388470490520570648720
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
87
GRP adjustable elbowpultruded, with integrated splice plates, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
Available in radius around 600 mm & 900 mm.
ULBA 100.150
7032 100 150ULBA 100.200 7032 100 200ULBA 100.300 7032 100 300ULBA 100.400 7032 100 400ULBA 100.450 7032 100 450ULBA 100.500 7032 100 500ULBA 100.600 7032 100 600ULBA 100.750 7032 100 750ULBA 100.900 7032 100 900
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959013959020959037959044959051959068959075959099959112
Weight 100 units
pc
220212217223226228234242251
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
Reducerpultruded
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering. The dimensions B1 and B2 allow to define the reduction size to use
to reduce or increase the cables ladder width
The splice plates ULGH 100/ ULIH 100 V4A are not included in the cables ladders, please order themseparately.
ULRU 100.100
7032 100 100ULRU 100.150 7032 100 150ULRU 100.200 7032 100 200ULRU 100.300 7032 100 300ULRU 100.400 7032 100 400ULRU 100.500 7032 100 500ULRU 100.600 7032 100 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
960019960026960033960040960057960064960071
Weight 100 units
pc
5155657895
109117
When mounting, the reducer must be supported by a bracket. The dimension B corresponds to thereduction. To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP vertical adjustable or with fixed angle splice platepressed, vertical
Need: 2 pieces for each cut, to be ordered separatly
for connecting cable ladders and fittings H80, with adjustable or fixed splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULGV 100
7032 100K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
960255
Weight 100 units
27,5
88
CABLE LADDER SYSTEM UL
Vertical splice plateStainless steel, vertical
Need: 2 pieces for each cut, to be ordered separatly
for connecting cable ladders and fittings H100, with adjustable splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULIV 100 E4
90E5
Item ref. Height
mm
Min. pack.
1 set
EANcode
960293
Weight 100 units
30
89
GRP cable ladderspultruded
L = fixing distance (m)
Load
q (k
N/m
)
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5 from thesupport. If this distance is not respected, it is necessary to raise the deflection values by approx. 30%.
The cables ladders have the advantage to be 100% GRP (Glass Reinforced Polyester ), thanksto unique patented clip-in rungs assembly, without metallic or thermoplastic parts.The cables ladders are delivered with non perforated rungs. However the option of perforatedrungs is still possible, please contact us.
Load diagram : q = load evenly distributed cables (according to DIN EN IEC 61537 standard)
UL 150.150/3
7032 150 150 6UL 150.200/3 7032 150 200 6UL 150.300/3 7032 150 300 6UL 150.400/3 7032 150 400 6UL 150.450/3 7032 150 450 6UL 150.500/3 7032 150 500 6UL 150.600/3 7032 150 600 6UL 150.750/3 7032 150 750 6UL 150.900/3 7032 150 900 6UL 150.150 7032 150 150 6UL 150.200 7032 150 200 6UL 150.300 7032 150 300 6UL 150.400 7032 150 400 6UL 150.450 7032 150 450 6UL 150.500 7032 150 500 6UL 150.600 7032 150 600 6UL 150.750 7032 150 750 6UL 150.900 7032 150 900 6
K23
K23K23K23K23K23K23K23K23K23K23K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Materialthickness
(th)mm mm mm
Min. pack.
3 m3 m3 m3 m3 m3 m3 m3 m3 m6 m6 m6 m6 m6 m6 m6 m6 m6 m
EANcode
965168965175965182965199965205965212965229965243965267958405958412958429958436958443958450958467958481958504
Weight 100 units
m
553,5570,3603,3636,8653,6670,3660,0754,1804,3553,5570,3603,3636,8653,6670,3660,0754,1804,3
End cap for GRP cable ladderpultruded
Used for: Cable ladders UL…H150 L3 and UL…H150 L6
Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
ULKE 150.150
7032 150 150ULKE 150.200 7032 150 200ULKE 150.300 7032 150 300ULKE 150.400 7032 150 400ULKE 150.450 7032 150 450ULKE 150.500 7032 150 500ULKE 150.600 7032 150 600ULKE 150.750 7032 150 750ULKE 150.900 7032 150 900
K23
K23K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
965632965649965656965663965670965687965694965717965731
Weight 100 units
pc
16,420,428,436,340,344,352,264,276,1
90
CABLE LADDER SYSTEM UL
GRP horizontal splice platepressed, horizontal
for connecting cable ladders and fittings H…, with splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULGH 150
7032 138 250K23
Item ref. RAL colour
Height LengthL
mm mm
Min. pack.
1 set
EANcode
960187
Weight 100 units
pc
38
When fixing the splice plates ULIH… and ULGH..., an expansion distance of about 3 mm must beconsidered.
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H150
ULIH 150 E4
138 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960224
Weight 100 units
27
mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 150
7032 102K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958542
Weight 100 units
m
80
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 150/ ULIH 150 V4A are not included in the cables ladders, please order themseparately.
Available in radius 250 mm, 600 mm und 900 mm
ULTE 150.150
7032 150 150ULTE 150.200 7032 150 200ULTE 150.300 7032 150 300ULTE 150.400 7032 150 400ULTE 150.450 7032 150 450ULTE 150.500 7032 150 500ULTE 150.600 7032 150 600ULTE 150.750 7032 150 750ULTE 150.900 7032 150 900
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959464959471959488959495959501959518959525959549959563
Weight 100 units
pc
650800999
120013001200125016601910
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
77
Horizontal stainless steel splice platehorizontal
for horizontal changes of directions and for the connection of cable ladders and fittings H53
ULIH 53 E4
45 Ø 8 20x8E4
Item ref. Height perforation For oblong perforations LL
mm mm mm
Min. pack.
1 set
EANcode
960194
Weight 100 units
6,1
Mount cable ladders with a space of 3 mm minimumThe holes in the splice plates ensure a solid fixing and allow the GRP material expansion. During the assembly, please verify that the splice plates oblong holes are located on the same side asthe supporting bracket. To help fixing the stainless steel splice plates ULIH, we recommend to use afork-type self locking plier ULP.To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP separatorpressed
to separate cables with different functions and / or to separate voltages
ULTL 53
7032 30K23
Item ref. RAL colour
Height
mm
Min. pack.
3 m
EANcode
958511
Weight 100 units
m
60
The GRP cover is fixed with self-tapping screws which are screwed in the ladder siderails and on thecover return flange or with rivets through the ladder siderails.
GRP tee junction cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULTE 53.150
7032 53 150ULTE 53.200 7032 53 200ULTE 53.300 7032 53 300ULTE 53.400 7032 53 400ULTE 53.500 7032 53 500ULTE 53.600 7032 53 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959235959242959259959266959273959280
Weight 100 units
pc
550590620720760830
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 53/ ULIH 53 V4A are not included in the cables ladders, please order themseparately.
ULX 53.150
7032 53 150 —ULX 53.200 7032 53 200 —ULX 53.300 7032 53 300 —ULX 53.400 7032 53 400 —ULX 53.500 7032 53 500 —ULX 53.600 7032 53 600 —
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
B+D
mm mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959570959587959594959600959617959624
Weight 100 units
pc
687,5738,0775,0900,0950,0
1.050,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
91
GRP cross for cable ladderpultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 150/ ULIH 150 V4A are not included in the cables ladders, please order themseparately.
Available in radius 250 mm, 600 mm und 900 mm
ULX 150.150
7032 150 150ULX 150.200 7032 150 200ULX 150.300 7032 150 300ULX 150.400 7032 150 400ULX 150.450 7032 150 450ULX 150.500 7032 150 500ULX 150.600 7032 150 600ULX 150.750 7032 150 750ULX 150.900 7032 150 900
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959808959815959822959839959846959853959860959884959907
Weight 100 units
pc
812,51.000,01.247,01.540,01.650,01.500,01.900,02.110,02.830,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP elbow 90°pultruded, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
The splice plates ULGH 150/ ULIH 150 V4A are not included in the cables ladders, please order themseparately.
Available in radius 250 mm, 600 mm und 900 mm
ULB 150.150
7032 150 150ULB 150.200 7032 150 200ULB 150.300 7032 150 300ULB 150.400 7032 150 400ULB 150.450 7032 150 450ULB 150.500 7032 150 500ULB 150.600 7032 150 600ULB 150.750 7032 150 750ULB 150.900 7032 150 900
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
958788958795958801958818958825958832958849958863958887
Weight 100 units
pc
548,7584,4656,0830,0880,0930,0
1.050,01.068,01.087,0
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
92
CABLE LADDER SYSTEM UL
GRP adjustable elbowpultruded, with integrated splice plates, not perforated rungs
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering.
Available in radius around 600 mm & 900 mm.
ULBA 150.150
7032 150 150ULBA 150.200 7032 150 200ULBA 150.300 7032 150 300ULBA 150.400 7032 150 400ULBA 150.450 7032 150 450ULBA 150.500 7032 150 500ULBA 150.600 7032 150 600ULBA 150.750 7032 150 750ULBA 150.900 7032 150 900
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
959129959136959143959150959167959174959181959204959228
Weight 100 units
pc
400410420430435440450470480
During assembly, all the fittings must be supported at every cables entry, add a centrale support for allfittings with radius greater than 250 mm, and/or with width greater than 400 mmTo ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
Reducerpultruded
The fittings are delivered with non-perforated rungs. However the option with perforated rungsis still possible, please ask us. The siderails are made in pultruded GRP. The splices plates are available in GRP, or instainless steel, please specify the material when ordering. The dimensions B1 and B2 allow to define the reduction size to use
to reduce or increase the cables ladder width
The splice plates ULGH 150/ ULIH 150 V4A are not included in the cables ladders, please order themseparately.
ULRU 150.100
7032 150 100ULRU 150.150 7032 150 150ULRU 150.200 7032 150 200ULRU 150.300 7032 150 300ULRU 150.400 7032 150 400ULRU 150.500 7032 150 500ULRU 150.600 7032 150 600
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
960088960095960101960118960125960132960149
Weight 100 units
pc
77102102126153200200
When mounting, the reducer must be supported by a bracket. The dimension B corresponds to thereduction. To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
GRP vertical adjustable or vertical fixed angle splice platepressed, vertical
Need: 2 pieces for each cut, to be ordered separatly
for connecting cable ladders and fittings H80, with adjustable or fixed splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULGV 150
7032 138K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
960262
Weight 100 units
27,5
93
Vertical splice platevertical, stainless steel
Need: 2 pieces for each cut, to be ordered separatly
for connecting cable ladders and fittings H150, with adjustable splice plates
To ensure a correct installation, the stainless steel splice plates must be fixed on each cable ladderend with 8 bolts M6x16V4A and the GRP splice plates must be fixed with 8 bolts M6x20V4A (must beordered separately)
ULIV 150 E4
138E4
Item ref. Height
mm
Min. pack.
1 set
EANcode
960309
Weight 100 units
30
94
CABLE LADDER SYSTEM COVERS UL
Cover for cable trays and cable ladderspressed
For a stronger assembly, the covers with a width above 400 mm are strengthened. Thesestrengthenings / ribs are visible on the outside face of the part.Used for: Cable tray H50, H80 and H110 mm, KK…, KKL… and cable ladder UL…H53, H80, H100
and H150 mm
KKD 50
7032 50KKD 100 7032 100KKD 150 7032 150KKD 200 7032 200KKD 250 7032 250KKD 300 7032 300KKD 400 7032 400KKD 450 7032 450KKD 500 7032 500KKD 600 7032 600KKD 750 7032 750KKD 900 7032 900
K23
K23K23K23K23K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
3 m3 m3 m3 m3 m3 m3 m3 m3 m3 m3 m
1,5 m
EANcode
956104956111956128956135956142956159956166956173956180956197956210956234
Weight 100 units
pc/
4778
105132152190243285292338438585
For a strong and compliant assembly, we recommend to leave a minimum distance of 8 mm betweenthe covers and the sidewalls of cable trays. Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
Cover for horizontal elbow 90°pressed
For a stronger assembly, the covers with a width above 400 mm are strengthened. Thesestrengthenings / ribs are visible on the outside face of the part.Used for: Horizontal elbow 90° H53, H80, H100 and H150, ULB…
Cover for elbow available in radius R250, R600 and R900 mm
ULBD 150
7032 150ULBD 200 7032 200ULBD 300 7032 300ULBD 400 7032 400ULBD 450 7032 450ULBD 500 7032 500ULBD 600 7032 600ULBD 750 7032 750ULBD 900 7032 900
K23
K23K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957422957439957446957453957460957477957484957507957521
Weight 100 units
pc
115126210270330380490565683
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for vertical adjustable elbow
For a stronger assembly, the covers with a width above 400 mm are strengthened. Thesestrengthenings / ribs are visible on the outside face of the part.Used for: Vertical elbow 53 mm high, ULBA...
ULBAD 53.150
7032 150ULBAD 53.200 7032 200ULBAD 53.300 7032 300ULBAD 53.400 7032 400ULBAD 53.500 7032 500ULBAD 53.600 7032 600
K23
K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
059188059195059218059225059232059249
Weight 100 units
26,533,347,961,273,685,2
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, stormsfor example, the quantity of clips must be increased.
95
GRP cover for vertical adjustable elbowpressed
For a stronger assembly, the covers with a width above 400 mm are strengthened. Thesestrengthenings / ribs are visible on the outside face of the part.Used for: Vertical elbow 80 mm high, ULBA...
ULBAD 80.150
7032 150ULBAD 80.200 7032 200ULBAD 80.300 7032 300ULBAD 80.400 7032 400ULBAD 80.500 7032 500ULBAD 80.600 7032 600
K23
K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
059256059263059270059287059294059317
Weight 100 units
29,437,053,268,081,894,6
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, stormsfor example, the quantity of clips must be increased.
GRP cover for vertical adjustable elbowpressed
For a stronger assembly, the covers with a width above 400 mm are strengthened. Thesestrengthenings / ribs are visible on the outside face of the part.Used for: Vertical elbow H100, ULBA...
Cover for elbow available in radius R600 & R900 mm
ULBAD 100.150
7032 150ULBAD 100.200 7032 200ULBAD 100.300 7032 300ULBAD 100.400 7032 400ULBAD 100.450 7032 450ULBAD 100.500 7032 500ULBAD 100.600 7032 600ULBAD 100.750 7032 750ULBAD 100.900 7032 900
K23
K23K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957538957545957552957569957576957583957590957613957637
Weight 100 units
pc
32,941,359,576,183,791,4
105,8137,1183,1
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, stormsfor example, the quantity of clips must be increased.
GRP cover for vertical adjustable elbowpressed
For a stronger assembly, the covers with a width above 400 mm are strengthened. Thesestrengthenings / ribs are visible on the outside face of the part.Used for: Vertical elbow 150 mm high, ULBA...
Cover for elbow available in radius R600 & R900 mm
ULBAD 150.150
7032 150ULBAD 150.200 7032 200ULBAD 150.300 7032 300ULBAD 150.400 7032 400ULBAD 150.450 7032 450ULBAD 150.500 7032 500ULBAD 150.600 7032 600ULBAD 150.750 7032 750ULBAD 150.900 7032 900
K23
K23K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
059089059096059119059126059133059140059157059164059171
Weight 100 units
38,147,969,088,297,1
106,0122,7159,0212,4
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, stormsfor example, the quantity of clips must be increased.
96
CABLE LADDER SYSTEM COVERS UL
GRP cover for tee junctionpressed
Used for: T H53, H80, H100 et H150, ULTE…
ULTED 150
7032 150ULTED 200 7032 200ULTED 300 7032 300ULTED 400 7032 400ULTED 450 7032 450ULTED 500 7032 500ULTED 600 7032 600ULTED 750 7032 750ULTED 900 7032 900
K23
K23K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957644957651957668957675957682957699957705957729957743
Weight 100 units
pc
51556269748188
105118
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
GRP cover for crosspressed
For a stronger assembly, the covers with a width above 400 mm are strengthened. Thesestrengthenings / ribs are visible on the outside face of the part.Used for: GRP ladder cross H53, H80, H100 and H150, ULX…
ULXD 150
7032 150ULXD 200 7032 200ULXD 300 7032 300ULXD 400 7032 400ULXD 450 7032 450ULXD 500 7032 500ULXD 600 7032 600ULXD 750 7032 750ULXD 900 7032 900
K23
K23K23K23K23K23K23K23K23
Item ref. RAL colour
WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
957750957767957774957781957798957804957811957835957859
Weight 100 units
pc m/
758090
100105110120135150
Covers are attached by using stainless steel cover clips DF…V4A, DF M… and DFUB… In extremeweather conditions, strong winds, storms for example, the quantity of clips must be increased.
Cover fixing clipstainless steel
for fixing the cables tray covers and fittings
Used for: Cable tray cover KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... and KKRRD...
DF 50 E4
55DF 80 E4 85DF 100 E4 110DF 150 E4 150
E4
E4E4E4
Item ref. Height
mm
Min. pack.
50 p.50 p.50 p.50 p.
EANcode
957873957880957897957903
Weight 100 units
pc.
1,72,12,33,4
Under normal conditions, it is recommended to mount 1 clip each meter alternatively every 3 meters.Under extreme weather conditions, such as strong winds or storms, the quantity of clips must beincreased.
Wall-mounted angle plateasymetrical
for fixing the cables ladders on the floor, or for a ceiling mounting and for a wall mounting.
Mounting accessories required : M10x30 V4A (to be ordered separately)
ULKV E4
5E4
Item ref. Materialthickness
(th)mm
Min. pack.
1 p.
EANcode
960330
Weight 100 units
pc
20
97
Cover fixing
Used for: Cover for cable tray KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... und KKRRD…
DFUB 5.5X19 E4
N E4
Item ref. Min. pack.
50 p.
EANcode
062065
Weight 100 units
0,64
For fixing the cover, it is necessary to drill a 8,2 mm diameter hole for the diameter. In extremeweather conditions such as strong winds, for example, the quantity of clips must be increased.
Steel tape for cover
The DFW is composed by :- 2 GRP profiles- 2 stainless steel threaded rods
to secure the cover fixing in extreme weather conditions (strong wind)
DFW 53.150
7032 53 150DFW 53.200 7032 53 200DFW 53.300 7032 53 300DFW 53.400 7032 53 400DFW 53.500 7032 53 500DFW 53.600 7032 53 600DFW 80.150 7032 80 150DFW 80.200 7032 80 200DFW 80.300 7032 80 300DFW 80.400 7032 80 400DFW 80.500 7032 80 500DFW 80.600 7032 80 600DFW 100.150 7032 100 150DFW 100.200 7032 100 200DFW 100.300 7032 100 300DFW 100.400 7032 100 400DFW 100.450 7032 100 450DFW 100.500 7032 100 500DFW 100.600 7032 100 600DFW 100.750 7032 100 750DFW 100.900 7032 100 900DFW 150.150 7032 150 150DFW 150.200 7032 150 200DFW 150.300 7032 150 300DFW 150.400 7032 150 400DFW 150.450 7032 150 450DFW 150.500 7032 150 500DFW 150.600 7032 150 600DFW 150.750 7032 150 750DFW 150.900 7032 150 900
E4 K23
E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23E4 K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
968022968039968046968053968060968077968084968091968107968114968121968138968145968152968169968176968183968190968206968213968220968237968244968251968268968275968282968299968305968312
Weight 100 units
pc
31,036,647,658,769,880,831,837,348,459,470,581,532,538,049,160,265,771,282,398,9
115,533,539,050,161,166,672,283,299,8
116,4
98
CABLE LADDER SYSTEM ACCESSOIRES UL
Ladder fixing hold down clampin GRP
Need : 2 pieces per support
for the fixing of cable ladders and fittings, on the brackets KTA, FPAP
Fixing accessories for FPAP: 2 bolts M10x30 V4A per bracket, with large washer, to be orderedseparately.The maximum admissible torque is 8 Nm for the hold down clamp. Fixing accessories for KTA : 2 bolts M6x30 V4A per bracket, to be ordered separately.
ULKG
7032 4K23
Item ref. RAL colour
Materialthickness
(th)mm
Min. pack.
1 p.
EANcode
960316
Weight 100 units
pc
3
Ladder fixing hold down clampsteel
Need : 2 pieces per support
for the fixing of cable ladders and fittings, on the brackets KTA, FPAP
Fixing accessories for FPAP: 2 bolts M10x30 V4A per bracket, with large washer, to be orderedseparately,The maximum admissible torque is 8 Nm for the hold down clamp. Fixing accessories for KTA : 2 bolts M6x30 V4A per bracket, to be ordered separately.
ULKH E4
E4
Item ref. Min. pack.
1 p.
EANcode
960323
Weight 100 units
20
BoltIncluded nut and washer
Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E5
for fixing the cables ladders on the brackets
BKM 6X30 E4
6 30E4
Item ref. ThreadM
LengthL
mm
Min. pack.
100 p.
EANcode
968336
Weight 100 units
pc
1,7
Dome head boltIncluded nut and washer
Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4
FKM 6X16 E4
6 16FKM 6X20 E4 6 20
E4
E4
Item ref. ThreadM
LengthL
mm
Min. pack.
100 p.100 p.
EANcode
962693962709
Weight 100 units
pc
1,21,4
Dome head boltIncluded nut and washer
Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4
FKM 8X20 K01
8 20K01
Item ref. ThreadM
LengthL
mm
Min. pack.
100 p.
EANcode
962716
Weight 100 units
pc
0,4
Hexagon head boltIncluded nut and washer
Also named M6x16V4A for FKM 6x16 E4, M6x20V4A for FKM 6x20 E4, M8x20PA6 for FKM 8x20K01, M10x30V4A for SKM 10x30 E4
SKM 10X30 E4
10 30SKM 10X40 E4 10 40
E4
E4
Item ref. ThreadM
LengthL
mm
Min. pack.
100 p.100 p.
EANcode
962730962747
Weight 100 units
pc
4,55,1
99
Cover fixing
Used for: Cover for cable tray KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... und KKRRD…
DF M
K01
Item ref. Min. pack.
50 p.
EANcode
957927
Weight 100 units
pc.
0,2
For fixing the cover, it is necessary to drill a 8,2 mm diameter hole for the diameter. In extremeweather conditions such as strong winds, for example, the quantity of clips must be increased.
Wall-mounted angle platesymetrical
for mounting on the ceiling, the wall and on the floor.
WWU 150/8 E5
4 1 SKM 8x16 E5E5
Item ref. Materialthickness
(th)
Accessories/bolts
includedmm
Min. pack.
50 p.
EANcode
728909
Weight 100 units
pc.
14,62
Fork-type self-locking plier
for the splice plates mounting
ULP 100
Item ref. Min. pack.
1 p.
EANcode
960347
Weight 100 units
pc
40
Trunking
Divider
Fittings
LFGLFGLFGLFGTrunking system available in heights
LFGSystemSystem
LFGLFGLFGLFGLFG 40 50 80
100
CABLE TRAY SYSTEM GFK
Especially used in extreme conditions trunking EBO Systems LFG in GRP is ideal in many areas such
as industrial plants, factories, waste water treatment installations, refi neries, offshore oil platforms,
photovoltaic system, tunnels, building or food industry.
Large variations in temperature do not affect the mechanical properties of the trunking.
LFGLFGTrunkingsystem available in heights
101
Available siderail heights 40 50 80
GRP-Trunking, pultruded LFG 103 103 103
GRP-Splice plate with clip, pressed KPGH 40 103 ––––– –––––
GRP-Splice plate with clip, pressed KPGH 50 ––––– 103 –––––
GRP-Splice plate with clip, pressed KPGH 80 ––––– –––– 103
Clamp for cables holding LFGKH 103 103 103
GRP-Endcap, pultruded KPKE 104 104 104
GRP-Divider, pultruded LFGT/...M ––––– 104 104
GRP-External elbow 90°, pultruded LFGAC 104 104 104
GRP-Internal elbow 90°, pultruded LFGIC 104 104 104
GRP-Horizontal elbow 90°, pultruded LFGWC 105 105 105
All trunkings and accessories are delivered with covers.
SYSTEM
ACCESSORIES
* suitable for all heights.
40
40
50
50
80
80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
102
RACEWAY SYSTEM LFG
Available siderail heights 40 50 80
GRP-Trunking, pultruded LFG 103 103 103
GRP-Splice plate with clip, pressed KPGH 40 103 ––––– –––––
GRP-Splice plate with clip, pressed KPGH 50 ––––– 103 –––––
GRP-Splice plate with clip, pressed KPGH 80 ––––– –––– 103
Clamp for cables holding LFGKH 103 103 103
GRP-Endcap, pultruded KPKE 104 104 104
GRP-Divider, pultruded LFGT/...M ––––– 104 104
GRP-External elbow 90°, pultruded LFGAC 104 104 104
GRP-Internal elbow 90°, pultruded LFGIC 104 104 104
GRP-Horizontal elbow 90°, pultruded LFGWC 105 105 105
All trunkings and accessories are delivered with covers.
SYSTEM
ACCESSORIES
* suitable for all heights.
40
40
50
50
80
80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
102
RACEWAY SYSTEM LFGTRUNKING SYSTEM LFG
103
GRP trunkingpultruded, with cover, and cable fixing clamps
LFG 40.060
7032 40 57 2 LFGKH 60 2,0LFG 50.100 7032 50 100 2 LFGKH 100 2,5LFG 50.150 7032 50 150 2 LFGKH 150 2,5LFG 50.200 7032 50 200 2 LFGKH 200 2,5LFG 80.100 7032 80 100 2 LFGKH 100 2,5LFG 80.150 7032 80 150 2 LFGKH 150 2,5LFG 80.200 7032 80 200 2 LFGKH 200 2,5LFG 80.300 7032 80 300 2 LFGKH 300 3,2
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
Accessories/bolts
included
Materialthickness
(th)mm mm mm
Min. pack.
2 m2 m2 m2 m2 m2 m2 m2 m
EANcode
948567948574948581948598948604948611948628948635
Weight 100 units
m
92160205265205328424500
Clipsable splice platepressed, horizontal, fixing with bolts
for the connection of cable trays and fittings H40, with splice plates H40
Mounting accessories required : 2 bolts M6x20 V4A ( to be ordered separately )
KPGH 40
7032 25K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955695
Weight 100 units
4,5
During the assembly, an expansion gap of 3 mm for dilatation must be considered.
Clipsable splice platepultruded, horizontal
for the connection of cable trays and fittings H50, with splice plates H50During the assembly, an expansion gap of 3 mm is automatically taken in consideration.
KPGH 50
7032 39K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955701
Weight 100 units
6
Clipsable splice platepultruded, horizontal
Need: 2 pieces for each cut
for the connection of cable trays and the fittings H80, with splice plates H80should be clipped on both cable trays sides.
KPGH 80
7032 69K23
Item ref. RAL colour
Height
mm
Min. pack.
1 set
EANcode
955718
Weight 100 units
22,5
During the assembly, an expansion gap of 3 mm for dilatation must be considered.
Hold down clamp for cablesPolyamid nylon
LFGKH 60
38LFGKH 100 75LFGKH 150 125LFGKH 200 175LFGKH 300 275
K13
K13K13K13K13
Item ref. WidthB
mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.
EANcode
948703948710948727948734948741
Weight 100 units
pc
0,20,61,7
17,030,0
104
RACEWAY SYSTEM LFG
End cap for cable traypultruded
for the cable tray ends
Used for: Cable tray H50, H80, KP…, KPL… and cable truncking LFG…
Mounting accessories required : 2 bolts M6x16 V4A ( to be ordered separately )
KPKE 40.060
7032 40 60KPKE 50.100 7032 50 100KPKE 50.150 7032 50 150KPKE 50.200 7032 50 200KPKE 80.100 7032 80 100KPKE 80.150 7032 80 150KPKE 80.200 7032 80 200KPKE 80.300 7032 80 300
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
955381955398955404955411955428955435955442955459
Weight 100 units
pc
5,56,09,0
10,08,0
11,013,020,0
GRP separatorpultruded
Used for: trunking LFG
Mounting accessories required : 1 bolt M6x20 V4A per meter ( to be ordered separately )
LFGT 50
7032 50LFGT 50/M 7032 50LFGT 80 7032 80LFGT 80/M 7032 80
K23
K23K23K23
Item ref. RAL colour
Height
mm
Min. pack.
2 m1 m2 m1 m
EANcode
948659968343948666968350
Weight 100 units
m
31314242
For a wall mouting or a ceiling mounting, the cable tray must not be in direct contact with the surface.The separator is supplied not mounted and must be fixed with bolts inside the cable tray, in its lengthat a specific distance from the cable tray sid
Vertical outside elbow 90°pultruded, with cover
Used for: trunking LFG
LFGAC 40.060
7032 40 60LFGAC 50.100 7032 50 100LFGAC 50.150 7032 50 150LFGAC 50.200 7032 50 200LFGAC 80.100 7032 80 100LFGAC 80.150 7032 80 150LFGAC 80.200 7032 80 200LFGAC 80.300 7032 80 300
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
967605948833948840948857948864948871948888948895
Weight 100 units
pc
4185
114137108154199301
Vertical inside elbow 90°pultruded, with cover
Used for: trunking LFG
LFGIC 40.060
7032 40 60LFGIC 50.100 7032 50 100LFGIC 50.150 7032 50 150LFGIC 50.200 7032 50 200LFGIC 80.100 7032 80 100LFGIC 80.150 7032 80 150LFGIC 80.200 7032 80 200LFGIC 80.300 7032 80 300
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
948758948765948772948789948796948802948819948826
Weight 100 units
pc/
31,065,086,0
103,072,0
100,0112,8239,5
Available siderail heights 40 50 80
GRP-Trunking, pultruded LFG 103 103 103
GRP-Splice plate with clip, pressed KPGH 40 103 ––––– –––––
GRP-Splice plate with clip, pressed KPGH 50 ––––– 103 –––––
GRP-Splice plate with clip, pressed KPGH 80 ––––– –––– 103
Clamp for cables holding LFGKH 103 103 103
GRP-Endcap, pultruded KPKE 104 104 104
GRP-Divider, pultruded LFGT/...M ––––– 104 104
GRP-External elbow 90°, pultruded LFGAC 104 104 104
GRP-Internal elbow 90°, pultruded LFGIC 104 104 104
GRP-Horizontal elbow 90°, pultruded LFGWC 105 105 105
All trunkings and accessories are delivered with covers.
SYSTEM
ACCESSORIES
* suitable for all heights.
40
40
50
50
80
80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
40 50 80
102
RACEWAY SYSTEM LFGTRUNKING SYSTEM LFG
105
Horizontal elbow 90°pultruded, with cover
Used for: trunking LFG
LFGWC 40.060
7032 40 60LFGWC 50.100 7032 50 100LFGWC 50.150 7032 50 150LFGWC 50.200 7032 50 200LFGWC 80.100 7032 80 100LFGWC 80.150 7032 80 150LFGWC 80.200 7032 80 200LFGWC 80.300 7032 80 300
K23
K23K23K23K23K23K23K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.1 p.1 p.1 p.1 p.1 p.1 p.1 p.
EANcode
948901948918948925948932948949948956948963948970
Weight 100 units
pc m/
30617684728999
200
BK/BKSBK/BKSBK/BKSBK/BKSBK/BKSSystemSystemBK/BKSBK/BKSBK/BKSBK/BKSBK/BKSGround ducts system available in heights 155
Ground ducts
Dividers
Covers
Accessoires
140 176 191
106
CABLE TRAY SYSTEM GFK
BK/BKSBK/BKSBK/BKSBK/BKSBK/BKSThe GRP EBO Systems ground ducts has been specially designed for outdoor use, with a quick
installation as well in the ground or in concrete.
The bases are supplied in lengths of 2.5 m, the connection is made by sleeving and without screws,
so the installation can be done by one man.
The ground ducts will be provided with an inking system during installation in the concrete. In case
of conditions of extreme loads, covers must be proposed in different thicknesses.
Covers
Accessoires
107
NEW
Available siderail heights
GRP ground ducts, pressed BK 109 ––––– 109 –––––
GRP divider, pressed BKT 109 ––––– 109 –––––
GRP ground ducts, pressed BKS ––––– 111 ––––– 111
GRP covers for ground ducts, pressed BKDR 110
Cover fi xing, with clips DF 94-4 110
Cover fi xing, with clips and hinge DF 94-C 110
Cover fi xing DF M 110
Cover fi xing DFUB 110
Steel ground ducts cover BKDR 110
SYSTEM
ACCESSORIES
140 155 176 191
140
140
140
155
155
155
176
176
176
191
191
191
108
GROUND DUCT SYSTEM BK/BKS
109
GRP ground ductpressed, not perforated
L = fixing distance (m)
Load
q (k
N/m
)
Warning : the deflection is measured with a junction position between 2 cable trays at a distance L/5 from thesupport. If this distance is not respected, it is necessary to raise the deflection values by approx. 30%.
for the installation inside and on the floor
Load diagram : q = load evenly distributed cables (according to DIN EN IEC 61537 standard)
BK 140.200
7032 140 124 200 192 4BK 176.300 7032 176 160 300 292 4BK 176.400 7032 176 160 400 392 4
K23
K23K23
Item ref. RAL colour
Height HeightH1
WidthB
widthB1
Materialthickness
(th)mm mm mm mm mm
Min. pack.
2,5 m2,5 m2,5 m
EANcode
952991953004953011
Weight 100 units
m
300,64406,30467,70
Interlocking and self-adjustable couplers, no screws required.
GRP separatorpressed
The divider BKT… is delivered notmounted, it can be fixed in the cable tray with a boltM 6x20V4A each 0,8 meter.The divider BKT…/M could be delivered pre-installed ( riveted ), the position inside the cabletray should be defined with the order.
to separate cables with different functions and / or to separate voltages
BKT 140
7032 107BKT 140/M 7032 107BKT 176 7032 143BKT 176/M 7032 143
K23
K23K23K23
Item ref. RAL colour
Height
mm
Min. pack.
2,5 m2,5 m2,5 m2,5 m
EANcode
057672057689057696057719
Weight 100 units
49506667
110
GROUND DUCT SYSTEM BK/BKS
Cover for cable ground ductpressed, cover fixed with splice plates, with grooves on the whole surface.
P = Load in N
F= d
efle
ctio
n in
mm
Used for: Pressed ground duct BK with siderail H140 mm & H176 mm
BKDR 200
7032 250 4,5BKDR 300 7032 350 4,5BKDR 400 7032 450 4,5
K23
K23K23
Item ref. RAL colour
WidthB
Materialthickness
(th)mm mm
Min. pack.
1,3 m1,3 m1,3 m
EANcode
956029956036948543
Weight 100 units
m
296400528
Cover fixing clipwith clip
Need : 3 pieces per cover
for the rigid fixing of the ground duct covers
Used for: Cover for cable ground duct BKDR 200-400
DF 94-4 E4
E4
Item ref. Min. pack.
1 p.
EANcode
948550
Weight 100 units
pc.
0,9
Cover fixing clipwith clip and hinge
Need : 3 pieces per cover
for fixing covers on cables trays
Used for: cover for cable ground duct BKDR 200-400
DF 94-C E4
E4
Item ref. Min. pack.
1 p.
EANcode
957866
Weight 100 units
pc.
10
Cover fixing
Used for: Cover for cable tray KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... und KKRRD…
DF M
K01
Item ref. Min. pack.
50 p.
EANcode
957927
Weight 100 units
pc.
0,2
For fixing the cover, it is necessary to drill a 8,2 mm diameter hole for the diameter. In extremeweather conditions such as strong winds, for example, the quantity of clips must be increased.
111
Cover fixing
Used for: Cover for cable tray KKD… and KPD…Cover for fittings KKCD..., KKBD..., KKWD..., KKBAD..., KKBID..., KKETD..., KKSTD...,KKSSD..., KKRLD... und KKRRD…
DFUB 5.5X19 E4
N E4
Item ref. Min. pack.
50 p.
EANcode
062065
Weight 100 units
0,64
For fixing the cover, it is necessary to drill a 8,2 mm diameter hole for the diameter. In extremeweather conditions such as strong winds, for example, the quantity of clips must be increased.
Cable tray for a ground installationpressed, not perforated
Warning : orientable concrete anchorage
to install on the ground, on earth or on concrete
BKS 155.200
7032 155 131 200 192 4BKS 191.300 7032 191 167 300 292 4BKS 191.400 7032 191 167 400 392 4
K23
K23K23
Item ref. RAL colour
Height HeightH1
WidthB
widthB1
Materialthickness
(th)mm mm mm mm mm
Min. pack.
2,5 m2,5 m2,5 m
EANcode
962303962310962327
Weight 100 units
m
354,40462,02525,40
Interlocking and self-adjustable couplers, no screws required
Steel cover for cable traywith a grooved steel cover on the whole surface
P = Load in N
F= d
efle
ctio
n in
mm
Used for: Heavy duty ground duct BKS with siderail H155 & H191 mm
BKDR 200-5 F
250 5BKDR 300-5 F 350 5BKDR 400-5 F 450 5BKDR 200-8 F
250 8BKDR 300-8 F 350 8BKDR 400-8 F 450 8
F
FFF
FF
Item ref. WidthB
Materialthickness
(th)mm mm
Min. pack.
1,3 m1,3 m1,3 m1,3 m1,3 m1,3 m
EANcode
956043956050956067956074956081956098
Weight 100 units
m
1.089,11.524,11.955,91.736,52.430,63.121,4
SPSPSPSPSPSPSystemSystemSPSPSPSPSPSelf standing cable troughing system for railways
150Self standing cable troughing system
112
CABLE TRAY SYSTEM GFK
The GRP EBO Systems cable troughing SP is an innovative product, validated by the Deutsche Bahn
and S-Bahn Berlin, it is particularly suitable in the facilities, impassable infrastructure, inaccessible
environments, or dented places .
A fl exible and economical installation due to the use of a system for supporting and fi xing HDG.
Lightweight lengths of 6m, perforations and lateral sides of the preassembled connecting fasteners
allow a quick and easy installation.
113
Stand-System SP
Material• no corrosion
• extremely insulating material, no need to earth
• dielectrical resistance 30 kV with a certifi cate issued by IPH Berlin
• fi re retardant property according to UL 94 : class V0
• halogen free
• UV resistant
• recyclable
Mounting • low weight
• Easy installation
• Delivered with perforations
• Delivery length 6 m
• Pre-assembled connectors allows a quick assembly
• The continuous installation allows variations of distances between supports
• the height of the system can be adjusted with variable pole lengths
• Particularly adapted to various topographical conditions
Load resistanceHigh mecanical resistance according to the specifi cations of the
Federal Bureau of railways and Mannesmann Arcor (Vodafone).
• Homologation number: EBA / 21AZ2 / 0029/9 du 16.11.1999
• Approved by DB Systel GmbH: T.SVN 15 10/12 du 27.05.2010
K23
Federal Bureau of railwaysDeutsche Bundesbahn
114
STAND SYSTEM SP
Contact us for solutions adapted to your special projects
Self standing cable troughing system SP a compact system for the elevation and cables support along railways
• cable trays with removable cover
• self standing cable trays up to 6 m
• supporting pole in HDG material
• pole head in HDG material
• cover fi xing with anti-theft bolts
115
Contact us for solutions adapted to your special projects
Self standing cable troughing system SP a compact system for the elevation and cables support along railways
• cable trays with removable cover
• self standing cable trays up to 6 m
• supporting pole in HDG material
• pole head in HDG material
• cover fi xing with anti-theft bolts
115
Stand-System SP
Posts and post head fi xing unit Because of the shape of the pole head a height adjustment is possible. During installation on uneven ground, the swivel-mountedpost head allows adjustment in three directions. The post head-fi xing unit is a single piece, thus making it easy and quick to install.All the bolt fi ttings are standard size M10x25. A possible shift of the post position during installation can be overhauled thanks to the oblong holes on the top of the post head.
Covers
Adjustable post head in 3 directions Post head adjustable in 2 directions
Overlapping of the covers through sleeves avoids the infi ltration of water.
The GRP cover is fi xed with impregnable screw, type Torx, and a cage nut.
Overlapping covers through sleeves Impregnable screw, type Torx
116
STAND SYSTEM SP
Splice plates The U-shaped connector made in 316 stainless steel secures perfectly the junction of each tray. Each 6 m length is delivered pre-assembled with a junction bolted on one side. The systems has been designed to be assembled by a single person whenever it is required. All the screws are round headed screws to avoid any cable injury. During the installation a 6 mm gap must be allowedbetween the tray lengths, and an 8 mm space between the tray covers.
DividerFor the separation of the cables (with different fonctions and/oraccording voltages).
The divider is maintained at the bottom of the tray through the cableweight, thus no additional hardware required during installation.
Splice plate pre-assembly in the factory Order of the srews
Round headed screws, observed an expansion joint
Divider
117
Stand-System SP
Rectangular cables spare
Fitting non-symmetrical, rectangular 1500 mm x 500 mm.The connection system to the cable tray is integrated.
Symmetrical cables spare
The fi tting is symmetrical, the center piece measured4500mm x 500 mm and 6000 mm in total, included coupling.The connection system to the cable tray is included.
118
STAND SYSTEM SP
8 mm6 m6 m
2,25 m 3 m 3 m 3 m
8 mm
6 m 6 m 6 m
4,5 m 6 m 6 m
8 mm
150
mm
150 mm
150
mm
250 mm
Instructions for assembly
Assembling the stand-SP system to support distance of 3 mAfter installing the first post, the second will be installed at a distance of about 2.25 m to respect the position of the holes in the bottom ofthe base.
Assembling the stand-SP system to support distance of 6 mAfter installing the first post, the second will be installed at a distance of about 4.50 m to respect the position of the holes in the bottom ofthe base.
Cable tray SP stand-system view profile
150 mm 250 mm
119
MCMCMCMCMCSystemSystem
MCMCMCMCMCHandrail profi les
End cap
Accéssoires
Handrail system
120
CABLE TRAY SYSTEM GFK
MCMCEBO Systems GRP handrails are ideal in tunnels and industrial facilities since a double function:
support cables and help users fi nd the exits in case of fi re hazard.
These handrails can also be used as a security system in all hallways, corridors and stairwells.
We offer handrails incorporating closed or not passages, with cables or not, with optional lighting
of safety equipment.
121
System overview of handrails
GRP-Handrail PR-MC 10 123
GRP-Handrail PR-MC 22 124
GRP-Handrail coupler PR-MC 10 GH 123
GRP-Wall mounting angle plate PR-MC 10 GM 123
GRP-End cap PR-MC 10 KE 123
Polyamid bolts PR-M860/PA6 123
GRP-Riveted end cap PR-MC 22 KE 124
GRP-Clipsable end cap PR-MC 22 KE/C 124
GRP-Half end cap PR-MC 22 KE/P 124
GRP-Clipsable half end cap PR-MC 22 KE/CP 125
Supporting clamp E30 PR-MC 22 HBV 125
GRP-Lighting support PR-MC 22 BA 123
GRP-Handrail PR-MC 30 126
GRP-Handrail coupler PR-MC 30 IH 126
GRP-Riveted end cap PR-MC 30 KE 126
Supporting clamp E30 PR-MC 30 HBV 126
SYSTEM
ACCESSORIES
122
HANDRAIL SYSTEM MC
123
Handrailpultruded, with integrated cable tray
PR-MC 10
7032K23
Item ref. RAL colour
Min. pack.
1 m
EANcode
965489
Weight 100 units
m
135
Splice platepultruded
Used for: Handrail PR-MC 10
PR-MC 10 GH
7032 20 150K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.
EANcode
968367
Weight 100 units
pc
9
Wall-mounted angle platepressed
for the lateral handrail fixing on site
Used for: Handrail PR-MC 10
PR-MC 10 GM
7032 90 95K23
Item ref. RAL colour
Height WidthB
mm mm
Min. pack.
1 p.
EANcode
968374
Weight 100 units
pc
15,6
Handrail end cappressed
for covering the profile ends
Used for: Handrail PR-MC 10
PR-MC 10 KE
7032K23
Item ref. RAL colour
Min. pack.
1 p.
EANcode
968381
Weight 100 units
pc
10
The end cap must be riveted on both sides
Polyamid bolt
for fixing the handrail on the wall-mounted angle plate
Used for: Handrail PR-MC 10
PR M860/PA6
K01
Item ref. Min. pack.
1 p.
EANcode
968398
Weight 100 units
pc
135
124
HANDRAIL SYSTEM MC
Handrailpultruded, 2 pieces, with integrated cable tray
PR-MC 22
7032K23
Item ref. RAL colour
Min. pack.
3 m
EANcode
965496
Weight 100 units
m
900
Riveted handrail end cappressed
For more safety, we recommend to add reflectors.
for covering the handrail ends
Used for: Handrail PR-MC 22
The reflectors will be added on request (to be ordered separately)
PR-MC 22 KE
7032K23
Item ref. RAL colour
Min. pack.
1 p.
EANcode
966172
Weight 100 units
pc
3,4
Clipsable handrail end cappressed
For more safety, we recommend to add reflectors.
for covering the handrail ends
Used for: Handrail PR-MC 22
The reflectors will be added on request (to be ordered separately)
PR-MC 22 KE/C
7032K23
Item ref. RAL colour
Min. pack.
1 p.
EANcode
966196
Weight 100 units
pc
3,9
The half end cap must be rivetedpressed
For more safety, we recommend to add reflectors.
for covering the handrail ends
Used for: Handrail PR-MC 22
The reflectors will be added on request (to be ordered separately)
PR-MC 22 KE/P
7032K23
Item ref. RAL colour
Min. pack.
1 p.
EANcode
966189
Weight 100 units
pc
1,6
125
The half end cap must be clippedpressed
For more safety, we recommend to add reflectors.
for covering the handrail ends
Used for: Handrail PR-MC 22
The reflectors will be added on request (to be ordered separately)
PR-MC 22 KE/CP
7032K23
Item ref. RAL colour
Min. pack.
1 p.
EANcode
966202
Weight 100 units
pc
1,8
Hold down clamp for cables E30stainless steel
Used for: Handrail PR-MC 22
PR-MC 22 HBV
E3
Item ref. Min. pack.
1 p.
EANcode
966219
Weight 100 units
pc
9
Lighting supportpressed
for the display of emergency exits on the handrail profile
Used for: Handrail PR-MC 22
PR-MC 22 BA
7032K23
Item ref. RAL colour
Min. pack.
1 p.
EANcode
966158
Weight 100 units
pc
75
126
HANDRAIL SYSTEM MC
Handrailpultruded, 2 pieces, with integrated cable tray
to separate the low voltage and high voltage cables
PR-MC 30
7032 6K23
Item ref. RAL colour
length unit
m
Min. pack.
3 m
EANcode
965502
Weight 100 units
m
450
Clipsable splice platestainless steel
Used for: Handrail PR-MC 30
PR-MC 30 IH
E4
Item ref. Min. pack.
1 p.
EANcode
966226
Weight 100 units
pc
9
End cap, (clippable)pressed, with reflector on request
For more safety, we recommend to add reflectors.
for covering the handrail ends
Used for: Handrail PR-MC 30
The reflectors will be added on request (to be ordered separately)
PR-MC 30 KE
7032K23
Item ref. RAL colour
Min. pack.
1 p.
EANcode
966233
Weight 100 units
pc
4,1
The half end cap must be riveted on both sides
Wall-mounted angle plate E30stainless steel
Used for: Handrail PR-MC 30
PR-MC 30 HBV
E3
Item ref. Min. pack.
1 m
EANcode
968404
Weight 100 units
135
127
NOTES
Thermoset resins
Plastic
Galvanizing process
INFOINFOINFOINFOInformation
128
CABLE TRAY SYSTEM GFK
On the following pages are gathered for you the most important information
on GRP cable tray systems with EBO Systems brand.
For more information you can contact us by calling +33 3 82 44 01 07
or by sending an email to: [email protected]
INFOINFOINFOINFO129
Thermoset resins
Thermoset resins reinforced with glassfi ber mats and glassfi ber rovings allow to obtain products of a very high holdingstrength and mechanics. Thermoset plastics after processing can not be deformed under the effect of heat. The thermosetresins used by Ebo Systems have very high chemical and physical properties. The use of these polyester resins, chargedwith glassfi bers, allow to obtain composite products, highly resistant to corrosion, electrically insulating with excellentmechanical characteristics, highly heat-resistant in comparison with other plastics (PVC , ABS). This material has a veryhigh fi re resistance, with self-extinguishing and fl ame retardant properties, without the addition of halogenated productsby the use of mineral materials. It can be possibly used for specifi c applications and EBO Systems has the possibility toadapt these recipes based on other requirements (special colors, special antistatic properties, etc ...).Ebo Systems exists for over 50 years and has developed its recipes to achieve these properties while maintaining highquality and innovative products.The expertise of Ebo Systems is its ability to always fi nd new recipes, develop new products which comply with thecustomer requirements at the fairest price.
Carbon loaded polyester resinThe carbon loaded polyester resin is used in explosive environments where it is necessary to prevent the accumulation ofelectrostatic charges by connecting the cable tray to the ground, when the humidity is below 50%.
Acrylic resinThis acrylic resin is used in niche markets to meet the most stringent fi re and smoke standards, particularly in the caseof underground long tunnels where the requirement for non-fl ammable products is very high. This is the case of specialtunnels as the Channel Tunnel where cable trays provided by Ebo Systems were made exclusively with an acrylic resin.
Vinylester resinThis resin is used in highly corrosive environments and in highly concentrated chemical environments.
Polyester ResinFor the standard product range, a polyester resin is often used. This allows to reach the main requirements in force andwith many adjuvants, up to 21 different, Ebo Sytems can meet some properties with a price / quality / level of service /very high report.
130
INFORMATION
Current corrosive atmosphere
Economy
Fire behaviour
Normal conditions-30°C à +80°C
Antistatic
Mechanicalresistance
Corrosionresistance
Minimum
Maximum
The nearer the curve to the outside of the hexagone, the better the solution.
Select your resins according to your technical specifications
Environmental featuresex: tunnel
Environmental featuresex: side of the sea, plateforme de forage
Environne-ment:
Strong atmospheric type corrosion (ex.: side of sea) Risk of fire in enclosed and corrosive environment(ex.: long tunnels)
Avantages: A very good holding in the time, a good behavior to fire, withoutrisk, for an optimal cost
An excellent resistance to fire for a maximal security
Our recom-mendation:
Polyester resinSelf-extinguishing polyester 0% halogen
Acrylic resinSelf-extinguishing avrylic 0% halogen
Environne-ment:
Highly exploding atmosphere (ex: mines, gas groups I) Strong content of highly corrosive chemical agents(ex : H2SO4, HCI, ...)
Avantage: The antistatic properties A high resistance to the chemical corrosion
Specific corrosive atmosphere Environnemental features
ex: mine gas groups I Environnemental features
ex: in the galvanazing environment
Our recom-mendation:
Carbon loaded polyester0% halogen
Vinylester 0% halogen
131
Modifi cation of plasticTo ensure the installation it is best to store the paths Ebo Systems cable before installing to temperatures higher than0° C and less than 40° C. However, the cable tray may be stored at temperatures - 40° C to over 150° C
Symbolcatalog
Abbrevi-ation
Material name Temperature zone, always
Mechanical properties Application(Exemples)
Stresscracking
K01 PA POLYAMIDE -30°Cto 80°C
compact, hard, very hard, verysharp, abrasive
Attaching cables, shimsmaintains fi xing cables,mounting clip
low
K02 PS POLYSTYRENE -30°Cto 60°C
deformable inner drive, compact, very hard
Attaching cables, mountingclamps, against fi xing
intense
K03 PE POLYETHYLENE -40°Cto 80°C
soft to hard, sharp, low behavior Protective caps, againstfi xing
intense
K04 PP POLYPROPYLENE -40°Cto 90°C
compact form, hard, full, slightlymalleable
Bottom bracket, clamp,needle attachment
possible
K05 PC POLYCARBONATE -40°Cto 120°C
high hardness, hardness andelongation, impact resistance
A fi xing clip possible
K06 SBR/NBR
STYRENE BUTADIENE RUBBER/NITRILE BUTADIENE RUBBER
-30°Cto 100°C
good abrasion resistance andweather
Toric seal no
K07 CR CHLOROPRENE RUBBER
-40°Cto 120°C
good resistance to chemicalsand aging
Toric seal no
K08 NBR NITRILE BUTADIENERUBBER
-40°Cto 120°C
fl exible cold, high elasticity, lowresistance to extreme conditions
Toric seal no
K09 PVC POLYVYNIL CHLORIDE
-20°Cto 65°C
compact holding hardness,shear sensitive
Plastic trunking low
K10 SOFT-PVC
SOFT POLYVYNIL CHLORIDE
0°Cto 50°C
fl exible, soft, good slidingproperties
Protective cap no
K11 ABS ACRYLONITRILEBUTADIENE STYRENE
-30°Cto 80°C
very hard even at low tempera-tures, scratch resistant hard
Mounting plate, to form partof the plastic ducts
low
K12 ASA ACRYLONITRILESTYRENEACRYLATE
-30°Cto 85°C
shockproof cold holding equivalent to the ABS
Box reserves low
K13 PC/ABS POLYCARBONATE/ACRYLONITRILEBUTADIENESTYRENE
-30°Cto 90°C
high impact and notched impactstrength, good heat defl ection
NX-Offi ce low
K14 POM POLYOXYME-THYLENE
-40°Cto 100°C
high shear stability and shock,good heat resistance
A fi xing clip poor
K15 SBR STYRENE BUTADIENERUBBER
-50°Cto 100°C
hard, thick, compact, even athigh temperatures, good elasticbehavior
Toric seal no
K16 CR/NBR CHLOROPRENE RUBBER/ NITRILE BUTADIENE RUBBER
-20°Cto 100°C
good wear resistance, goodresistance to cold and hottemperatures
Toric seal no
K17 CR/SBR CHLOROPRENE RUBBER/STYRENE BUTADIENE RUBBER
-20°Cto 70°C
good elasticity, impact resi-stance to improved weather
Toric seal no
K18 TPE THERMOPLASTICELASTOMER
-40°Cto 120°C
good wear resistance, poorresistance to heat and cold
Toric seal no
K19 FS 31 PHENOLIC RESIN to 125°C excellent resistance to weathe-ring, ozone and aging
Versions proposées low
K20 SI SILICON RUBBER -40°Cto 180°C
good wear resistance, highhardness, good heat resistance
Toric seal no
K21 PUR POLYURETHANE -25°Cto 60°C
good resistance to scratching, to abrasion and torsion
Industrial pipes, glue seal low
K22 PET POLYETHYLENETEREPHTHALATE
-40°Cto 190°C
high hardness, low moistureabsorption
proposed versions low
UP-GF GLASSFIBERRE-INFORCEDPOLYESTER
-50°Cto 80°C
good hardness, good wear resi-stance and temperature
Cable trays and ladders,profi le construction, hand rail
low
Plastic materials
K23
132
INFORMATION
You can find more information about the resistance to chemical agents on our website: www.ebo-systems.com !
Resistance to chemicals
Symbol catalog
Water: Acids (10 %):
Base(10 %):
Alcohl(Ethanol):
Benzine: Benzol: Mineral oil: Vegetable and animal fat:
Chemical products
K01 + o + + o + o + o
K02 + o + + - - o o +
K03 + + + + o - o + -
K04 + + + + o o + + o
K05 + o - + - - + + o
K06 + o o + - - o o o
K07 + - - + o + o o o
K08 + o + + + o + o o
K09 + + + + + - + + -
K10 + + o + - N.R. - 0 -
K11 + o N.R. + - - + - -
K12 + o o + - - + + -
K13 + + + o o - + o -
K14 + o o + + + + + -
K15 + + + + - - - - o
K16 + o o + o - + + o
K17 + o o N.R. - - o N.R. N.R.
K18 + + + N.R. + N.R. + N.R. -
K19 + o o + + o + N.R. o
K20 + o o + o - + + o
K21 + - - N.R. + N.R. + + o
K22 + + o + + o + N.R. o
+ + + + + o + + +
+ = good performance o = medium performance - = low performance N.R. = no result
References: Table of contents, eg manual Plastic Author:Franck, Publisher: Vogel-BuchverlagThe data in the table are approximate values for product selection and are based on known results to date.The qualities can negatively change depending on the geometry and external conditions.Detailed data will be submitted with the offer price. To check the resistance of a product must achieve a specific test inthe outdoor environment.
K23
133
Polyester resin 0% hologen
PropertiesStandard references
andStandard designations
Country of origin
(Lab)
PRESS type resin
R96Tests Output
PULTRUSION type resin
R6204Tests Output
Units
Fire behavior
Inflammability ASTM D 6194 / IEC 60695-2-12Glow wire test
USA / International(CREPIM,
Bruay)
960 960 °C
Inflammability UL 94Test for flammability of plastic materials
USA(LNE)
V0 V0 -
Fire propagation NF P 92-507Fire behavior of building materials
France not tested not tested -
Flame Spread &Smoke Developed Index
ASTM E84 / UL 723Surface burning characteristics of building
Uniforme Building Code class(SDI max = 450)
USA(Underwriters
Lab.)
FSI = 25SDI = 350
Class I
FSI = 35SDI = 450Class II
IndexIndex
-
Spread of Flame BS 476 Part 7Surface spread of flame test for materials
England(Uni. Gent)
Class 2 Class 2 -
Fire propagation BS 476 Part 6Fire propagation test for materials
England(WFR)
18,3 14,1 Index
Flammability & SmokeIndex
NF F 16-101Fire behavior of materials for rolling stock
France(CREPIM,
Bruay)
I2F0
I2F1
IndexIndex
Smoke Developed Index BS 6853 App B52Fire precautions in the design and construction
of rolling stock
England(WFR)
Ao(on max) = 10,47Ao(on end) = 9,89
Ao(off) = 11,23
Ao(on max) = 17,34Ao(on end) = 14,79
Ao(off) = 18,75
IndexIndexIndex
Limiting Oxygen Index ASTM D 2863 / ISO 4589-2Results of the fire resistance according
to the oxygen index
USA / International(CREPIM,
Bruay)
> 32% > 32% %
Fire protection Index VKFAssociation of cantonal fire assurances
Switzerland(Swissi Basel)
5.3 5.3 Index
Fire Standard DIN 4102 (Not operational as per 12: Fire resistance of materials and parts, class level)
Germany(FMPA,
Stuttgart)
B2Classe d‘indice
B2Classe d‘indice
Fire Standard DIN 5510-2 Preventive Fire Protection in railwayvehicles Part 2: Fire behaviour and fire side effects
of materials and partsAppendix C: FED (30 min ) < 1
Germany(RST,
Henningsdorf)
S4/SR2/ST2FED(30 min) =0,13
S4/SR2/ST2FED(30 min) =0,03
IndexIndex
Mechanical behavior
Tensile Strength at breakpoint
ISO 527-5 International(Serma
Technologies)
~ 55 ~ 187 MPa
Modulus of Elasticity ISO 527-5 International(Serma
Technologies)
~ 7200 ~ 11900 MPa
Accelerated Ageing Testexposure
ISO 4892-2 / ISO 527-5Mechanical and UV resistance
International(Serma
Technologies)
Good mechanicaland chromatic
behaviour
Good mechanicaland chromatic
behaviour
-
Accelerated Ageing Testby salt spray exposure
ISO 9227 / ISO 527-5Mechanical and salt spray resistance
International(Serma
Technologies)
Good mechanicaland chromatic
behaviour
Good mechanicaland chromatic
behaviour
-
Accelerated Ageing Test byUV and salt spray exposure
ISO 4892-2 / ISO 9227 / ISO 527-5Mechanical, UV and salt spray resistance
International(Serma
Technologies)
Good mechanicaland chromatic
behaviour
Good mechanicaland chromatic
behaviour
-
134
INFORMATION
Press resin applies for the K2 (previously called KK) and BK rangePultruded resin applies for the KP and UL ranges.
Conformity according EN 61537 / IEC 61537:
Impact test: K², KP, UL, ML series have successfully passed the shock test with an energy of 20 J (Degree of protection: IK10)Flame propagation test: K², KP, UL, ML series are non-flame propagating.CE marking: Our products comply with the directive BT/73/23/CEE according to the harmonized standard EN 61537 : 2001
PropertiesStandard references
andStandard designations
Country of origin
(Lab)
PRESS type resin
R96Tests Output
PULTRUSION type resin
R6204Tests Output
Units
Electrical behavior
Surface Resitivity &Measure of the dischargefrom a charged surface
IEC 60079-0 : Suitable with gas groups International
(LCIE)~ 4.109
IIA,IIB,IIC> 1011
IIA,IIB,IICΩ-
Breakage Voltage IEC 60243-1 : International(IPH) > 15 non-tester kV/mm
Comparative tracking index IEC 60112 : International(LCIE)
575 600 V
Passager ship
Acceptance in passengership
ABS (ABS) approuvéK2
approuvéKP - UL
Others
Density 1,8 1,8 g/cm3
Thermal conductivity 0,3 0,3 W/m.K
Linear Thermal DilatationDIN 53752 -
Détermination du coefficient de dilatation thermique
Germany ~ 36 x 10-6 ~ 8 x 10-6 cm/cm/K
Water Absorption ISO 62Determination of water absorption
Germany 0,16 0,3 %
Table = valid at time of printing!! 135
Steelthe material with the many positive characteristics: non-fl ammable, high mechanicalresilient, magnetized, shielding effect (Faraday), no static electricity, fi re load-free, halogen-free, 100% fully recyclable.This exceptionally good, constructive, technological, mechanical and physical properties contribute towards the high utility value and quality of the produced Niedax of cable laying systems.The many benefi ts precludes a weak point: steel can rust.With a well-conducted galvanizing However, this weakness is effectively and cost to overcome. Steel and zinc complement each other perfectly.
Good all-round protectionis due to the formation of protective, adherent coatings on the zinc. On the new products initially forms a zinc oxide fi lm, which is converted to zinc hydroxide or zinc carbonate under the infl uence of humidity and carbon dioxide (zinc patina). These protective layers are formed, depending on the surrounding atmosphere, in a few days to several weeks.
Cathodic protectionor surface protection mean refers to the ability of zinc to protect the cutting surfaces or other surface damage upon exposureto moisture to corrosion. This capability is based on the more negative of the zinc compared to zinc in the iron statusof the „electrolytic voltage range“. A galvanizing can not rust for the same reason. The cut surface protection is effectiveup to a material thickness of 2 mm.Adequate ventilation galvanized components is mandatory. Under unfavorable storage and transport conditions (humidconditions, little or no airfl ow) may form on freshly galvanized surfaces known as white rust (loose porous zinc hydroxide).White stains may also appear by a dry storage and an un-suffi cent air access to all surfaces (possibly with stacking wood shims use). Outdoor storage under sheets or tarpaulins should be avoided.Niedax cable laying systems made of steel are generally used only in a galvanized fi nish.*) This term corrosion protectionsaves valuable natural resources and is thus a signifi cant contribution to environmental protection. As corrosion protectionfor the Niedax cable laying systems come, operational and manufacturing reasons, the galvanizing process described inmore detail in the following summaries are used.
Galvanized steel - the perfect material
*) For exceptional, aggressive environmental conditions cable laying systems are made of stainless steel or fi berglass reinforced Plastic available.!136
INFORMATION
Galvanizing Processes
Components over 2 mm in material thickness are hot dip galvanized at Niedax Local environmental conditions would be for instance the direct corrosive effect of a chimney with CO2 flue gases. Chromating process is ROHS compliant.
1
2
3
Liquid Dip Process ElectrolyticProcess
F S V
Process standardHot Dip Galvanizing (HDG) after fabrication
according to DIN EN ISO 1461(DIN EN ISO 10684 for hardware)
Continuous Strip Galvanization (Sendzimir Process)
according to DIN EN 10 346
Electrolytic Galvanizing (Electroplating)according to DIN EN ISO 2081
(DIN EN ISO 4042 for hardware)
Structure and composition of the coatingAlloying with the
base materialAlloying with the
base materialLaminated coating
Usual thickness of the zinc layerDepending on the thickness of the
material to be galvanized, up to 1.5 mm thickness approx. 45 μm, up to 3 mm thickness approx. 55 μm, up to 6 mm thickness approx. 70 μm
Layer thickness Z 140: 10 μm + 3 μmLayer thickness Z 275: 20 μm + 5 μm
according to DIN EN 10 346
approx. 2.5 to 20 μm, inundercuts and recesses
(thread flanks) the layer thickness is less than on open surfaces
Special featuresEach component is individually dipped
in the liquid zinc bath. The zinc washes over the entire surface.
Hollow sections are protected on the in- and outside. Rigid corrosion protection
The corrosion protection layer is applied to the surface by passing
the steel as a continuous ribbon through a bath of molten zinc.
The zinc layer is deposited from an aqueous electrolyte by means of DC current.
Post-treatment is generally applied to improvethe protective effect. Decorative visual appea-
rance, smooth surface with no edges and burrs.
Distinguishing featuresThe surface is relatively rough,and solidified zinc may block
small holes. Newly galvanizedsurfaces are bright shining; high
temperature galvanized partsuch as screws are grey.
Smooth surface depending on theprocess, slightly greased. Holes and cut edges
expose “bare metal“. Corrosion protection of “bare“ edges up to 2 mm material thickness is provided by the by cathodic protection effect.
Iridescent shimmer, bright and shiny surface after passivation.
Usage - ApplicationWelded components,equipment exposed
to the weather.
Non-welded components upto 2 mm thick, especially for
interior building work.
For parts in almost all shapes and sizes, corrosion protection and decorative finish. Recommended for dry, indoor areas only.
Corrosion Protection (typical annual degredation for Central Europe)
Corrosion Protection
Depending on the atmospheric conditions and the local environment.
Rural 0.1 - 1.0 μmSuburban 1.0 - 2.0 μm
Marine 2.0 - 4.0 μm
Annual degradation almost unmeasurable in dry indoor areas
without pollution.
Salt spray tests according to DIN EN ISO 9227 NSS show up to 360 hours before rusting depen-
ding on the thickness of the zinc layer and the passivation method.
1
2
3
137
Batch galvanizing(Hot-dip galvanisation) according to DIN EN ISO 1461 (DIN EN ISO 10684 for hardware)
By immersion in liquid zinc (hot-dip process, ca. 450° C), the entire surface, including all corners and edges lapped. On the steel is an iron-zinc alloy layer forms with an overlying layer of pure zinc. The layer thickness depends on the material thickness and is according to DIN EN ISO 1461 to 1.5 mm material thickness 45 microns, up to 3 mm thick 55 microns and up to 60 mm material thickness 70 microns. Due to the very hard iron-zinc alloy layer can batch-galvanized components, without damaging the zinc surface, not deformed.
Application examples from the Niedax program: All components with welded joints, for example, suspension struts, cable and pipe clamps as well as products with more than 3 mm thick, cable trays / ladders, wide span cable trays / ladders and many more, as far as increased demands on the corrosion resistance (weathering without rain shield).
Strip coating(Sendzimir Process) according to DIN EN 10346The zinc coating is on both sides, applied by a zinc bath on broadband in the run. The project uses the modifi ed Sendzi-mir. On the steel is an iron-zinc alloy layer forms with an overlying layer of pure zinc. The layer thickness of the Sendzi-mirbandes used for Niedax cable laying systems is under consideration of the test method according to DIN EN 10346 according to three surface sample depending on the product group 10 - 20 microns.
Strip galvanisation is used for components up to max. 2 mm material thickness, as up to this strength, a suffi cient edge protection is achieved by „cathodic protection“. The process-related „bare iron“ interfaces of the components are in use in dry interiors, by the cathodic protection effect is not a disadvantage. Strip galvanized components can be formed without damaging the zinc surface.
Application examples from the Niedax program:Cable trays / ladders, wide span cable trays / ladders, cable ladders, cable protection ducts, light boom, rails up to 2 mmthickness. In dry indoor areas without aggressive media, the strip galvanizing provides permanent corrosion protection.
Zinc coating
Selon DIN EN ISO 2081 (DIN EN ISO 4042 for hardware)The zinc coating is applied in aqueous electrolytes by means of direct current. To improve the corrosion protection canbe carried out by an aftertreatment thick layer passivation and blue passivation according to DIN 50961.The zinc coating is 2.5 to 20 microns. Parts with undercuts, such as C-shaped armature rails, due to the process lessheavily coated inside than outside (Faraday cage).
Application examples from the Niedax program:Small parts (screws, washers up to max. 6 M), mounting rails and screws for distribution board, but with additional thicklayer passivated.
Galvanizing
GV
F
S
138
INFORMATION
Coat with zinc dust paintThe zinc-rich paint shall be such that in the dry film more than 90% zinc is included. To avoid the formation of cracks in the coating, the coating is applied in several steps.
Application examples in connection with the Niedax program:Improvements, particularly assembly-related injuries of the zinc surface by welds or the like.
Additional plastic coatingHot Dip Galvanizing components with a polyester epoxy resin coating
The products marked with C1 are hot-dip galvanized and polyester resin with an epoxy coating in a thickness of 60 - 80 microns provided. When using indoors this plastic coating ensures excellent corrosion protection as well as high mecha-nical resistance and is resistant to most chemicals.
The zinc coating is thus protected by the overlying coating from atmospheric and chemical influence. A removal of me-tallic zinc is avoided, so that the zinc coating remains intact for a long time under the coating in mint condition.
For special use in the outdoor area, we are pleased to offer other coatings
C1
For detailed information about the zinc can be found in the cited standards as well as in a voluminous literature offer.! 139
InternatIonal SaleS agencIeSAustralianiedax australia Pty. ltd. level 28, 1 Market StreetSydney, nSW 2000Mr. chris Ivkovic . tel: +61 488 222 [email protected]@niedax.com.au . www.niedax.com.au
Belgiumniedax-Kleinhuis n.V.tulpenstraat 2B-9810 eke/nazarethtel: +32 92200790 . Fax: +32 [email protected]
Brazilniedax Participações Societárias ltda.rua Verbo Divino, 1661 Br-04719-908 São Paulotel: +55 19 38782566 . Fax: +55 19 [email protected]
LithuaniaJSc „Swelbalt“Sudmantu kaimas92498 Klaipèdos rajonastel: +370-46-300 100 . Fax: +370-46-300 [email protected] . www.swelbalt.lt
LuxembourgMinusines S.a.B.P. 2212; 8, rue Hogenbergl-1022 luxemburg-gasperichtel: +352 495858 . Fax: +352 [email protected] . www.minusines.lu
Mexiconiedax de Mexico S.a. de c.V.Priv. lomas de la carcana 10 aJ.a. Santiago Momoxpanc.P. 72760 San Pedro cholula, Mexicotel: +1 6149218469 . Fax: +1 [email protected]
EstoniaPoweram elektriseadmed oÜlohu 12, 12618 tallinntel: +372 672 6833 . Fax: +372 672 [email protected] . www.poweram.ee
Finlandapstek oyaleksanterinkatu 15BFIn-00100 Helsinkitel: +358 40 [email protected]
Franceniedax FranceParc d‘activités Washingtonav. de la ferme du roy, Fr-62404 Béthune cedextel.: +33 321 64 75 75 . Fax: +33 321 64 75 [email protected] . www.niedax-group.com
BruneiJoffren omar company Sendirian BerhadHead Office Seria Lot 49-51 Sg. Bera light Industrial area Seria KB1933, negara Brunei Darussalamtel: +673 3223 863 . Fax: +673 3223 309
Bulgarianiedax BulgariaFilip-Kutev-Str. 137BG-1407 Sofiatel: +359 29624574 . Fax: +359 [email protected]
DenmarkDuelco a/SSystemvej 8-10DK-9200 aalborg SVtel: +45 70101007 . Fax: +45 [email protected] . www.duelco.dk
Italyniedax eBo Italia S.r.l.con Socio Unico, Via roma, 118I-20040 cavenago di Brianza (MB)tel: +39 0295339124 . Fax: +39 [email protected] . www.niedax.com
Indianiedax cable Management Systems Pvt. ltd.# 1007, Prestige Meridian I, 29 Mahatma gandhi roadBangalore - 560 [email protected] . www.niedax.co.in
IndonesiaJakartaNiedax Asia Pacifific Pte. LtdMr. raharjo Wicaksonotel: +62 816 171 696 [email protected]
Ireland/UKniedax cMS ltd.clash Industrial estateIrl-tralee, co. Kerry, Irelandtel: +353 667128701 . Fax: +353 [email protected] . www.niedax-group.com
Franceebo Systems S.a.S.Zone Industrielle, avenue Jean Monnet, BP 5F-54920 Villers-la-Montagnetel.: +33 382440107 . Fax: +33 [email protected] . www.ebo-systems.com
GCC Statesniedax Middle east FZeP.o. Box 262461FZS2ac08, Jebel ali, Uae-Dubaitel: +9714 880 7970 . Fax: +9714 880 [email protected] . www.niedax.com
Netherlandsniedax-Kleinhuis B.V.Bijsterhuizen 21-03; nl-6604 le WijchenPostbus 6694; nl-6503 gD nijmegentel: +31 243788533 . Fax: +31 [email protected] . www.niedax.nl
Norwayeaton electric aSProst Stabels vei 22, n-2019 SkedsmokorsetP.o. Box 244, n-2021 Skedsmokorsettel: +47 63870200 . Fax: +47 [email protected] . www.moeller.no
PakistanIndustrial Supplies & engineering associatesPo BoX 8103 Baghbanpura lahore-9, P.o. code: 54920tel: +92 [email protected] . [email protected]
Romania niedax romania s.r.l.Soseana chitilei nr. 3, sector 1ro-012381 Bucurestitel: +40 216680280 . Fax: +40 216680280 [email protected] . www.niedax-group.com
PhilippinesPoWereDge™ Solutions Phils Inc285-a Haig St Brgy Daang BakalMandaluyong city 1552Office: (02) 5355552-53www.poweredge.com.ph
Russianiedax oooleningradsky Prospekt 76/3125315 Moskautel: +7 499 654 02 32 . Fax: +7 499 654 02 [email protected]
Polandniedax-Kleinhuis Polska Sp.zo.o.ul. Zagòrska 133Pl-42-680 tarnowskie gòrytel: +48 323819810 . Fax: +48 [email protected] . www.niedax.pl
SerbiageMeX d.o.oZrenjanski put 103b11210 Belgradtel: +381 11 33181 . Fax: +381 11 [email protected]
SingaporeNiedax Asia Pacific Pte. Ltd.21 Bukit Batok crescent, Wcega tower, Unit 16 - 70Singapore [email protected] www.niedax-group.com
Slovak Republic niedax Slowakia s.r.o.Pestovateľská 6SK-82104 Bratislavatel: +421 244630934 . Fax: +421 [email protected] . www.niedax.sk
SloveniaKabeltrade d.d.o.latkova vas 83B, 3312 Preboldtel: +386 3 620 24 [email protected]
0914
Hungaryniedax Kereskedelmi Kft.Budafoki út 10.H-2030 Érdtel: +36 23521300 . Fax: +36 [email protected] . www.niedax-group.com
Peru/Equador/BoliviaKombau Peru S.a.c.av/larco 1116 Int. cMiraflores Limatel: +51 968134880 . Fax: +51 [email protected] . www.kombau.net
Thailandniedax (thailand) ltd.62/10 M6, t Samnaktorn, a. Ban changrayong 21130 thailandtel: +66 (38) 963 258 . Fax: +66 (38) 963 [email protected]
USAniedax Inc.2970 charter Streetcolumbus, oH 43228 USatel: +1 6149218469 . Fax: +1 [email protected] . www.niedaxusa.com
VietnamNiedax Asia Pacifific Pte. LtdHo chi Minh [email protected]
LatviaaS ernergoFIrMa JaUDaKrustpils street 119lV-1057 riga, latVIatel: +37 67725789 . Fax: +37 [email protected] . www.jauda.com
KoreaHansung SystemrM # 301 nexvill, 1301-2, Baekseok-Dong, Ilsan-dong-gu, goyang-Si, Kyunggi-Do, Korea, 410-817tel: +82 31 908 [email protected]
CroatiarS Kabel d.o.o.Savska cesta 41/VI, Poslovni to10144 Zagrebtel: +385 1 611 2038 . tel: +385 1 631 [email protected] . www.rs-kabel.hr
Spainniedax-Kleinhuis Ibèrica S.l.U.c/Italia 5 y 7e-28971 grinón (Madrid)tel: +34 918103197 . Fax: +34 [email protected] . www.niedax.com
Switzerlandniedax eBo Schweiz agWehreyering 21 PostfachcH-3930 Visptel: +41 279456868 . Fax: +41 [email protected]
SwedenFasteus teknik aBMagasinsgatan 35S-43437 Kungsbackatel: +46 30051000 . Fax: +46 [email protected] . www.fasteus.se
ebo Systems
Production facility
Austrianiedax Kabelverlege-Systeme gmbHresselstraße 10a-2120 Wolkersdorftel: +43 2245901100 . Fax: +43 [email protected] . www.niedax.at
Czech Republicniedax-Kleinhuis s.r.o.Palackeho 701cZ-27746 Veltrusytel: +42 0315781116 . Fax: +42 [email protected]
ICONS
Please ask for the Certifications VDE/UL
AL Aluminium (N = naturally anodized, * = powdercoated in RAL colors)P Electrotechnical Porcelain MS Brass CU Copper
E1 Material Code.: 1.4016Stainless SteelE2 Material Code.: 1.4310
Founded in 1959 in Switzerland ( Zurich), EBO Systems was one of the first companies in Europe to specialise in the design and manufacturing of profiles for the support and installation of electric cables.
In 1972, a new production facility, specialised in the production of cable management systems, was set up at Villers-La-Montagne in France, in order to face up the increasing demand from different markets.
Since 1980 EBO Systems continues to invest and evolves to provide the best solution for the market, in addition to the hot press moulding technique, EBO Systems introduced the pultrusion technique and become the only manufacturer to supply to the customer two ranges of products.
To expand its range of products it develops and standardizes a new mix halogen-free and self-extinguishing which generates very little smoke in case of fire hazard.
Always at the forefront of new technologies Ebo Systems invests in an automated production of hot press moulding to reduce manufacturing lead times, increase quality and get the most competitive prices.With always the same goal: the customer satisfaction.
Ebo Systems joined in 2010 the German Niedax Group, one of the leading specialists in steel cables trays, thus strengthening its international presence.
E3 Material Code.: 1.4301, 1.4303E5 Material Code.: 1.4571E6 Material Code.: 1.4529
E4 Material Code.: 1.4401, 1.4404 E7 Material Code.: 1.4547E8 Material Code.: 1.4430E9 Material Code.: 1.4362
Steel Ebo Systems, always ahead…
But it is also …
Projets…
B Steel, bareV Steel, galvanized according to DIN 50 961, blued G Steel, galvanized according to DIN 50 961, passivatedS Steel, pre-galvanized according to DIN EN 10 327F Steel, hot dip galvanized after fabrication (HDGAF) according to DIN EN ISO 1461 (Replacement for DIN 50 976)
Steel, black-oxide finishSB
All products in this catalog are classified according to the EAN code (13 digits). The first 7 digits indicate the country (40 = Germany) and the manufacturer‘s code (13339 = Niedax). The following six digits are the product code. example EAN code of the product TK = 40 60.85 13339 183708.
0914
E10 Material Code.: 1.4307E11 Material Code.: 1.4034
FG
COLOR Steel, pre-galvanized and powdercoated
Steel, geomet® galvanized
CDV Steel, wire galvanized
Hardware
Fast Install
Siderail Height in mm
Wire Diameter in mm
Info
New
Installation Instructions
Reference Note
Pipe Diameter in mm
Cover hole and depth in mm
Discontinued model
No halogen
No silicone
C R W L WA N PComplete model-No. white creme white light grey white aluminium aluminium aluminiumfor the colour RAL 9010 RAL 9001 RAL 7035 RAL 9006 natural anodized plate-finishedidentity on stock O t h e r R A L c o l o u r s o n r e q u e s t s . F o r p o s s i b l e c o l o u r d i v e r g e n c e s w e a s s u m e n o l i a b i l i t y .
From Paris to Singapore via Dubai, EBO Systems is present in more than 27 countries becoming the global supplier of your projects in energy, transport and industrial building.
An efficient customer servicewith a unique contact who takes in consideration the customers requests, needs, specifications for your national and international projects.
A Research & Development department Able to give advices and propose personal study upstream, during and after your project, and provide a technical assistance on-site.
A logistics departmentwith a good experience of delive-ries around the world.
Respect for the environnement Ebo Systems engages in environ-nemental quality certification Iso 14001 and proceeds to products recycling.
Ebo Systems are tools of advanced production technology, combined with human expertise to over 50 years ...
STANDARD COLORES SURFACE IN ALUMINUM
F8 Steel, mechanical zinc plated / passivatedHigh quality coating. Corrosion resistance measured by means of a test salt spray according to DIN 50 021 (ASTM-B117-90) is at least 500 hours.
F9
F10
Steel, mechanical zinc plated / passivatedHigh quality coating. Corrosion resistance measured by means of a test salt spray according to DIN 50021 (ASTM-B117-90) is at least 600 hours.Steel, electrical mechanical / passivatedZinc coating thickness of 5 microns, electrolytically applied and clear passivated according to BS EN 12329 2000 FE/ZN5//A.
F6 Natural colorUntreated material against corrosion.
F7 Steel, plastic coatingEVA (Ethylene Vinyl Acetate Copolymer Saponifies) Levasint ®) resistance to fire according to DIN 4102.
F1 Steel, zinc coating and chromateSteel, zinc coating & chromate Thickness of zinc is between 8-12 microns, elec-trolytic galvanizing & additionally chromated. Corrosion resistance measured by using a salt spray test according to DIN 50021 (ASTM-B117-90) at least 72 hours.
F2 Steel, hot dip galvanizedThickness of zinc between 50-70 microns, after immersion machining in a bath of molten zinc.
F3 Stainless steel (material number. 1.4401 [316])Indoor use / Outdoor in humid environments and moderately aggressive.
F5 BrassFor indoor use only.
F4 Steel, coatedDekor-lacquer interior use in dry environments and not corrosive.
K10 PVC - PolyvinylchlorideK21 PUR - Polyurethane
K11 ABS - Acrilonitrile-Butadiene-Styrene
K13
K14
K15
K16
K17
K18
K19
K20
K12
K22 PET - Polyethylene Terephtalate, halogen free
K23
C1
Sales conditions 1. Opposability These sales conditions are sent with our bid to all purchasers to raise an order. Consequently, raising an order implies full , unreserved acceptance of these conditions, excluding any other type of document such as a brochure or catalogue, which only give approximate information. No special condition can have priority over these conditions, except if formal written approval is received from Ebo Systems. Furthermore, the purchaser renounces his own general purchasing conditions. The fact that Ebo Systems does not invoke, at a given moment, one of the present conditions, cannot be interpreted as being a renunciation of future invocations of such a condition
2. Contract validity Bids by Ebo Systems are only valid for a duration of 2 (two) months unless specified otherwise. Orders are only definitively accepted when they have been confirmed in writing by Ebo Systems and where applicable, after payment of the agreed advance. The fact that the purchaser does not reply within 8 (eight) days following the sending of written conformation, is equal to express acceptance by the purchaser. Should an order that has become definitive be cancelled, the entire purchase price will be invoiced to the purchaser and become immediately payable. Ebo Systems none the less reserves the right, in case of a drop in the credit rating of the purchaser, or if Ebo Systems has legi timate reason to consider that the purchaser will be incapable of paying the purchase price at the agreed deadlines: • either to cancel an order in progress, even if definitive • or to demand first rate guarantees, or a payment before delivery, it being understood that payment means effective cashing of the payment instrument. The order is specifically intended for the purchaser and cannot be transferred without prior written approval from Ebo Systems.
3. Object of the delivery Ebo Systems reserves the right to make any change to the presentation, shape, size and design at any time it considers useful to its products without being obliged to modify ordered goods being manufactured. Ebo Systems also reserves the right to modify, without prior warning, the products defined in its pamphlets and catalogues. None the less, in case of changes to standards or improvements to products ordered before delivery Ebo Systems reserves the right to make the technical changes necessary without the object ordered being modified
4. Shipment Any increase to cost of shipment, to taxes or miscellaneous duties occurring during performance of the contract is entirely paid by the purchaser except if there are special or contrary provisions in the price legislation. Special packaging, maritime freight or insurance where applicable, shall be invoiced at the tariff in force at the moment of shipment
5. Delivery turnaround times 5.1 Delivery turnaround times are given for information purposes and are not guaranteed. Ebo Systems is authorized to make global or partial deliveries. Overshooting of delivery times cannot give rise to compensation and interest, nor discounts or cancellations of orders, unless contrary provisions are agreed in writing with the purchaser. Ebo Systems may be released from its commitment to deliver in case of force majeur. Without this list being comprehensive, force majeur includes: war, uprisings, strikes or combined action by the personnel of the suppliers of Ebo Systems or service suppliers Ebo Systems uses to carry out orders 5.2 In all cases, delivery within the agreed turnaround times can only take place if the purchaser has fully satisfied all his commitments to Ebo Systems, no matter what the reason, especially those resulting from article 2 of these conditions.
6. Delivery costs and risks Goods are delivered in compliance with Incoterms I.C.C. dated January 2000. As of the delivery, as defined in Article 4 of these conditions, the goods travel at the expense and risk of the purchaser, who is responsible in case of damage or missing articles to make any necessary reservations and to take all steps to preserve his rights of action against the shipper. The shipper designated by Ebo Systems, works on the behalf of, at the expense of and risk of the purchaser. Unless prior written instructions are received from the purchaser, repeated for each shipment and reception confirmed by Ebo Systems, Ebo Systems is not bound to take out any insurance, declaration of value or make any declaration of interest at delivery on behalf of the purchaser, no matter what might be the value of the goods shipped. The costs relating to the services undertaken by Ebo Systems on behalf of the purchaser are fully invoiced to the purchaser. In no case whatsoever can Ebo Systems be held responsible for the method of payment selected and the tariff applied by the shipper.
7. Reception Notwithstanding any prejudice to the measures to take with regard to the shipper, claims for missing articles, visible defects or non-compliance of goods delivered with regard to goods ordered or the bill of lading, must be made in writing and sent by registered letter with acknowledgement, within 8 (eight) days following delivery of such goods. Beyond this period of time, no claim will be accepted. The purchaser shall leave Ebo Systems leeway to confirm these faults and to remedy them. The purchaser promises not to take any action himself, not bring in a third party for this purpose.
8. Return of products No return of products shall be carried out without prior written authorization from Ebo Systems. The cost and risk of return of products is always at the expense of the purchaser. In case of visible defects or the non-conformity of delivered goods, duly recorded by Ebo systems under the condition scheduled in Article 7 of these conditions, the purchaser may obtain reimbursement of the price paid, excluding any indemnity and compensation. On the other hand, if the claims made by the purchaser are not substantiated, Ebo Systems has the right to invoice him for all non-substantiated travel, goods inspection and transport expenses.
9. Guarantee Ebo Systems are ISO 9001 certified. Products are guaranteed against any functional fault for a duration of 6 (six) months as of the date of delivery. Under this guarantee, the only commitment encumbering Ebo Systems will be the reimbursement of the purchase price, excluding any compensation, no matter what it might be. In no case whatsoever can the liability of Ebo Systems exceed the price of the products. To be taken into account, any defective product under guaranteed must be returned at the expense and risk of the purchaser with a return note, once accepted by Ebo Systems.
10. Guarantee exclusions Any demand with an aim to implementing the guarantee can only be accepted if the purchaser is up to date with his financial commitments with regard to Ebo Systems. Defects and damage caused by normal wear, accidental causes, negligence, malicious intent, implementation not in compliance with good works practice, protection and safety standards, regulations in force, repair by third parties or even defective maintenance shall be excluded from the guarantee.
11. Price Products are provided at the price rate in force on the date of the order. Prices are net, ex plant, special packaging in addition.
12. Payment methods Invoices are payable cash on reception, by check, signed and accepted letter of credit, protest not being necessary or any other accepted method of payment. In case of payment by letters of credit, the purchaser is bound to return the letters accepted and signed within a maximum of 7 (seven) days. Payment according to these general sales conditions is not simply the fact of paying by check or by letter of credit, but its effective cashing at the scheduled date. Any drop to the purchaser credit rating may substantiate the demand for first rate guarantees or cash payment when ordering or payment by sight draft prior to execution of orders received or before the due date of issued invoices. Ebo Systems reserves the right at all times, according to the risks involved, to set a maximum credit allowance for each purchaser, it being understood that these modalities are valid for all orders in progress. The refusal by the purchaser to meet these conditions gives Ebo Systems the right either to cancel all or part of the orders or to demand immediate payment of all sums due.
13. Late payment or failure to pay In case of late payment, Ebo Systems may suspend all orders in progress without any prejudice to any other means of action. Any sum not paid at the scheduled payment time will give rise by full right and without any prior warning, to payment of late payment interest at a rate equal to one and a half times the legal interest rate in force in France, from the due date up to the payment date. In case of failure to pay forty-eight hours after formal notice without response, the sale shall be cancelled by full right if considered necessary by Ebo Systems, who can request restitution of products, without prejudice for other compensation. The resolution will not simply affect the order involved but also all previous orders whether delivered or being delivered and related payment, whether due or not. In case of payment by letter of credit, the returned letter shall be considered as a refusal to accept, assimilated to a failure to pay. Non-payment of a single invoice or at a payment date will result in the immediate payment of all sums due without other warnings. In all preceding cases, the sums due for other reasons or any other cause become immediately payable if Ebo Systems does not opt for the resolution of the corresponding orders. The purchaser shall reimburse, other than the principle and the interest, all expenses caused by the recovery by litigation of sums due, as well as a 15% (fifteen percent) penalty of the unpaid sum. In no case may payments be suspended or be the subject of any compensation without prior written approval from Ebo Systems. All partial payments shall first used to pay compensation and penalties, then the sums with the oldest due payment date. No failure to pay, or late payment, can be justif ied later by a claim. Lastly, reference to the stipulations made in Article 2 of these general sales conditions is made.
14. Transfer of risks Transfer of risks takes place as of the moment the goods are made available to the purchaser at a location agreed upon with Ebo Systems at the date, or within the stipulated time frame, or as of the moment such goods have been delivered to the terminal of the forwarder, agreed with the purchaser. As of this moment, the goods are shipped at the risk and the expense of the purchaser.
15. Right of ownership Ebo Systems reserves the ownership of delivered goods until the full payment of the sum due by the purchaser is received. The purchaser is bound to keep goods in perfect condition and to insure goods on behalf of the owner against all usual risks, especially loss, destruction or theft, with the indemnity being delegated in case of a problem to Ebo Systems. Ebo Systems must immediately be informed about any accident. The purchaser promises to immediately inform Ebo Systems in the case of settlement or judicial winding-up, in case of seizure or any other procedure initiated by a third party and to inform Ebo Systems of the exact location where delivered goods not yet paid for are stored. The purchaser promises not to use delivered unpaid for goods as security and in general not to carry out any operation likely to cause prejudice to the right of ownership of Ebo Systems. In case of resale of delivered goods, whether or not the purchaser is authorized, the purchaser declares now to declare to Ebo Systems the debt resulting from the sale to a sub-purchaser and authorizes Ebo Systems to cash the price paid by the sub-purchaser, up to the total sum of his debt with the purchaser. The purchaser promises to inform Ebo Systems immediately of the exact and complete identity of any sub-purchaser, who will be informed by the purchaser of the right of ownership by Ebo Systems, at the latest at the moment of signing the contract. Any violation by the purchaser with regard to the obligations stipulated in this clause or in the general sales conditions shall be sanctioned by full rights by the event of default. The claim by Ebo Systems to the goods of which the ownership is reserved is by means of registered letter with acknowledgement, sent to the purchaser, requiring him to return the goods in his possession to Ebo Systems. The claim of goods under reserve of ownership neither constitutes a resolution nor cancellation to the sales contract. The claim may be made by Ebo Systems in case of non-observance of any of the commitments by the purchaser, especially non-acceptance of a letter of credit, in which case Ebo Systems will have all legal rights to think that the purchaser is not capable of observing the agreed payment dates. All expenses caused by the claiming of goods or their corresponding sum are at the exclusive cost of the purchaser.
16. Court of competent jurisdiction and applicable law The court of competent jurisdiction is expressly allocated to the courts of BRIEY - France, who will decide on the application of French law unless Ebo Systems decides to nominate another court of competent jurisdiction.
CA
BLE
TR
AY S
YS
TEM
S 2
014
GR
P
NX
007
5 01
_GB
Ebo Systems S.A.S.Zone Industrielle BP 5F-54920 Villers-la-Montagne
Tel: +33 382440107Fax: +33 382261041
GRP CABLE TRAY SYSTEMSGLASS REINFORCED POLYESTER
2014
GRP
ALL PRODUCTS ARE CERTIFIED
competent.innovative.
customized.
Ebo Systems Ebo SystemsEbo Systems