14
GSPublisherVersion 70.0.88.79 DETAILED DRAFTING & DESIGN Sheet #: DRAWN BY: DCB 435-592-4287 C1.0 Revisions: Drawing Date: 1/4/2017 Scale: As Noted Sheet Contents: COVER SHEET DETAILED DRAFTING & DESIGN EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS INHERENT IN THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED DOCUMENTS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF DETAILED DRAFTING & DESIGN ALL INFORMATION CONTAINED IN THESES DRAWINGS, ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT BE REPRODUCED, DISCLOSED, CHANGED, OR COPIED WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF DETAILED DRAFTING & DESIGN FOR CONSTRUCTION SET 55 N 600 E, ST GEORGE, UT 84770 WWW.DETAILEDDRAFTING.COM INDEX OF DRAWINGS SHEET # C1.0 TITLE ROOF & SITE PLAN BUILDING SECTIONS LIVING SPACE 2,900 Sq Ft TOTAL 4,316 Sq Ft SQUARE FOOTAGE 464 Sq Ft BACK PORCH 828 Sq Ft GARAGE 124 Sq Ft COVERED ENTRY C1.1 C1.2 COVER SHEET IRC SPECS & METHODS IRC SPECS & METHODS A3.0 A1.1 A2.1 EXTERIOR ELEVATIONS A4.0 ELECTRICAL PLAN FLOOR PLAN A1.2 A2.0 EXTERIOR ELEVATIONS SPACES PROVIDED BEDROOMS 1 1 1 STUDY 3 BATH 3 1/2 1 LAUNDRY 3 CAR GARAGE 1 DINING KITCHEN STORAGE 1 1 FOYER GREAT ROOM

COM DETAILEDDRAFTING WWW

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

GSPublisherVersion 70.0.88.79

DET

AIL

ED

DR

AFT

ING

&

DES

IGN

Sheet #:

DRAWN BY: DCB435-592-4287

C1.0

Revisions:

Dra

win

g D

ate:

1/4

/201

7Sc

ale:

As

Not

ed

Shee

t C

onte

nts:

CO

VER

SH

EET

DET

AIL

ED

DRA

FTIN

G

&

DES

IGN

EX

PRES

SLY

RESE

RVES

IT

SC

OM

MO

N

LAW

C

OPY

RIG

HT

AN

D

OTH

ER

PRO

PERT

Y RI

GH

TSIN

HER

ENT

IN

THES

E PL

AN

S.

ALL

D

RAW

ING

S,

ELEC

TRO

NIC

FILE

S,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

ARE

INST

RUM

ENTS

O

F SE

RVIC

E A

ND

A

RE

THE

PRO

PERT

Y O

FD

ETA

ILED

D

RAFT

ING

&

D

ESIG

N

ALL

IN

FORM

ATI

ON

CO

NTA

INED

IN

TH

ESES

D

RAW

ING

S,

ELEC

TRO

NIC

FI

LES,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

IS

PRO

JEC

TSP

ECIF

IC

AN

D

SHA

LL

NO

T BE

RE

PRO

DU

CED

, D

ISC

LOSE

D,

CH

AN

GED

, O

R C

OPI

ED

WIT

HO

UT

FIRS

T O

BTA

ININ

G

THE

EXPR

ESS

WRI

TTEN

PE

RMIS

SIO

N

AN

D

CO

NSE

NT

OF

DET

AIL

ED D

RAFT

ING

& D

ESIG

N

FOR

CO

NST

RU

CT

ION

SET

55 N

600

E, S

T G

EOR

GE,

UT

8477

0W

WW

.DET

AIL

EDD

RA

FTIN

G.C

OM

INDEX OF DRAWINGS

SHEET #C1.0

TITLE

ROOF & SITE PLAN

BUILDING SECTIONS

LIVING SPACE 2,900 Sq Ft

TOTAL 4,316 Sq Ft

SQUARE FOOTAGE

464 Sq FtBACK PORCH828 Sq FtGARAGE

124 Sq FtCOVERED ENTRY

C1.1C1.2

COVER SHEETIRC SPECS & METHODSIRC SPECS & METHODS

A3.0

A1.1

A2.1 EXTERIOR ELEVATIONS

A4.0 ELECTRICAL PLAN

FLOOR PLANA1.2A2.0 EXTERIOR ELEVATIONS

SPACES PROVIDED

BEDROOMS

11

1

STUDY

3BATH 3 1/2

1LAUNDRY

3 CARGARAGE

1DININGKITCHEN

STORAGE 1

1FOYER

GREAT ROOM

GSPublisherVersion 70.0.88.79

DET

AIL

ED

DR

AFT

ING

&

DES

IGN

Sheet #:

DRAWN BY: DCB435-592-4287

C1.1

Revisions:

Dra

win

g D

ate:

1/4

/201

7Sc

ale:

As

Not

ed

Shee

t C

onte

nts:

IRC

SPE

CS

& M

ETH

OD

S

DET

AIL

ED

DRA

FTIN

G

&

DES

IGN

EX

PRES

SLY

RESE

RVES

IT

SC

OM

MO

N

LAW

C

OPY

RIG

HT

AN

D

OTH

ER

PRO

PERT

Y RI

GH

TSIN

HER

ENT

IN

THES

E PL

AN

S.

ALL

D

RAW

ING

S,

ELEC

TRO

NIC

FILE

S,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

ARE

INST

RUM

ENTS

O

F SE

RVIC

E A

ND

A

RE

THE

PRO

PERT

Y O

FD

ETA

ILED

D

RAFT

ING

&

D

ESIG

N

ALL

IN

FORM

ATI

ON

CO

NTA

INED

IN

TH

ESES

D

RAW

ING

S,

ELEC

TRO

NIC

FI

LES,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

IS

PRO

JEC

TSP

ECIF

IC

AN

D

SHA

LL

NO

T BE

RE

PRO

DU

CED

, D

ISC

LOSE

D,

CH

AN

GED

, O

R C

OPI

ED

WIT

HO

UT

FIRS

T O

BTA

ININ

G

THE

EXPR

ESS

WRI

TTEN

PE

RMIS

SIO

N

AN

D

CO

NSE

NT

OF

DET

AIL

ED D

RAFT

ING

& D

ESIG

N

FOR

CO

NST

RU

CT

ION

SET

55 N

600

E, S

T G

EOR

GE,

UT

8477

0W

WW

.DET

AIL

EDD

RA

FTIN

G.C

OM

IMPORTANT DISCLAIMER

IMPORTANT NOTE: THESE NOTES AND SPECIFICATIONS ARE PROVIDED BY THE DESIGNER AS A SERVICE TO THEIR CUSTOMERS TO PROVIDE THE MOST POPULAR CODE TOPICS. THE INFORMATION AND METHODOLOGIES PREPARED HEREIN ARE IN ACCORDANCE TO AND REFERENCED TO THE 2015 INTERNATIONAL RESIDENTIAL CODE . THE INFORMATION IS ALSO A GENERAL SUMMARIZATION OF THE CODE AND IT IS RECOMMENDED THAT YOU BECOME FAMILIAR WITH THE FULL EXTENT OF THE ACTUAL CODE. THE NOTES AND SPECIFICATIONS MAY HAVE TO BE AMENDED DUE TO VARIATIONS IN LOCAL CODES AND GEOLOGICAL CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND/OR HOMEOWNER TO MAKE THE NECESSARY MODIFICATIONS TO ENSURE CODE COMPLIANCE AND STRUCTURAL INTEGRITY. IT IS RECOMMENDED THAT YOU CONSULT A LOCAL ARCHITECT OR ENGINEER OF YOUR CHOICE AND CHECK WITH LOCAL BUILDING OFFICIALS PRIOR TO THE START OF ACTUAL CONSTRUCTION. SPECIAL ENGINEERING MAY REQUIRE THAT THESE SPECIFICATIONS BE CHANGED OR AMENDED TO COMPLY WITH SEISMIC, WIND, OR OTHER SPECIAL CONDITIONS AS REQUIRED BY LOCAL CONSTRUCTION METHODOLOGIES AND LOCAL CODES.

THE ENCLOSED INFORMATION IS INTENDED TO ASSIST AND INFORMYOU THROUGH THE CONSTRUCTION OF YOUR HOME. YOURCONSTRUCTION PLANS HAVE BEEN DRAWN TO PRESCRIBE TOINDUSTRY STANDARDS. THESE PROFESSIONAL STANDARDSDETERMINE HOW CONSTRUCTION PLANS ARE DRAWN AND WHATINFORMATION THEY INCLUDE. CONSTRUCTION PLANS ARE INTENDEDAS A TECHNICAL GUIDE TO PROFESSIONAL CONTRACTORS AND ARENOT INTENDED TO BE A SET OF STEP-BY-STEP INSTRUCTIONS.THEREFORE, IF YOU ARE PLANNING TO BUILD TO YOUR HOMEWITHOUT THE SERVICES OF PROFESSIONAL BUILDER. WESUGGEST THAT YOU BECOME THOROUGHLY FAMILIAR WITH READINGCONSTRUCTION PLANS OR CONSIDER CONSULTING ACONSTRUCTION SPECIALIST.

GREAT CARE AND EFFORT GOES INTO THE CREATION OF THEDESIGN AND DRAFTING OF YOUR CONSTRUCTION PLANS.HOWEVER, BECAUSE OF THE IMPOSSIBILITY OF PROVIDING ANYPERSONAL AND/OR "ON-SITE" CONSULTATION, SUPERVISION,CONTROL OVER THE ACTUAL CONSTRUCTION, AND BECAUSE OFTHE GREAT VARIANCES IN LOCAL BUILDING CODE REQUIREMENTSAND OTHER LOCAL BUILDING AND WEATHER CONDITIONS,OUR COMPANY NOR THEIR AGENTS OR EMPLOYEES, ASSUMES NORESPONSIBILITY FOR ANY DAMAGES, INCLUDING BUT NOT LIMITEDTO, ANY DEFICIENCIES, OMISSIONS, OR ERRORS IN THE DESIGN. INTHE DIMENSION, AND/OR DRAWINGS CONTAINED IN THECONTRACTION. PROCEEDING WITH CONSTRUCTION CONSTITUTESTHE ACCEPTANCE OF THE CONSTRUCTION DOCUMENTS AS "AS IS"AND ANY DISCREPANCIES, ERRORS AND/OR OMISSIONS BECOMETHE SOLE RESPONSIBILITY OF THE PURCHASER. IF ANY ERRORSARE DISCOVERED PRIOR TO CONSTRUCTION, THE DESIGNERWILL BE GIVEN FULL OPPORTUNITY TO CORRECT ANYERRORS AND/OR OMISSIONS TO THE CONSTRUCTION PLANS. IN ANYOR ALL CIRCUMSTANCES. THE MAXIMUM FINANCIAL LIABILITY TOTHE DESIGNER CAN NOT EXCEED THE TOTAL PLANPURCHASE.

PROFESSIONAL SEALTHOUGH EVERY EFFORT WAS MADE TO MAKE THE CONSTRUCTIONDOCUMENTS FOLLOW THE CURRENT I.R.C NATIONAL CODEMETHODOLOGIES, A FEW STATES AND CITIES HAVE PASSED BI-LAWS REGARDING CONSTRUCTION PLANS THAT WOULD BESUBMITTED TO YOUR LOCAL MUNICIPALITY AND USED FOR THECONSTRUCTION OF YOUR HOME. THESE BI-LAWS REQUIRE THECONSTRUCTION PLANS BE REVIEWED AND/OR PREPARED,INSPECTED, AND SEALED (OR STAMPED) BY A LICENSEDPROFESSIONAL ENGINEER OR ARCHITECT IN YOUR STATE. IT ISADVISED THAT YOU CONTACT YOUR MUNICIPALITY'S BUILDINGDEPARTMENT FOR INSTRUCTIONS TO COMPLY WITH THEIRCONSTRUCTION PLAN REVIEW PROCESS.

COPYRIGHTSREPRODUCTION OF THESE CONSTRUCTION PLANS, EITHER IN WHOLEOR IN PART, INCLUDING ANY FORM OF COPYING AND/ORPREPARATION OF A DERIVATIVE WORKS THEREOF, FOR ANY REASONIS STRICTLY PROHIBITED. THE PURCHASE OF A SET OFCONSTRUCTION PLANS IN NO WAY TRANSFERS ANY COPYRIGHT OROTHER OWNERSHIP INTEREST IN IT TO THE PURCHASER EXCEPTFOR A LIMITED LICENSING RELEASE TO USE THE SAID PLAN SETFOR PURPOSE OF CONSTRUCTING ONE, AND ONLY ONE,DWELLING UNIT. THE PURCHASE OF ADDITIONAL SETS OF THESAID PLANS AT A REDUCED PRICE FROM THE ORIGINAL SET OR ASPART OF A MULTIPLE SET PACKAGE DOES NOT CONVEY TO THEPURCHASER A LICENSE TO CONSTRUCT MORE THAN ONE DWELLING.SIMILARLY, THE PURCHASE OF REPRODUCIBLE CONSTRUCTION PLANS(A.K.A. SEPIAS, MYLARS, OR VELLUMS) CARRIES THE SAMECOPYRIGHT PROTECTION AS MENTIONED ABOVE. IT IS GENERALLYALLOWED TO MAKE ADDITIONAL COPIES FOR THE CONSTRUCTION OFA SINGLE DWELLING ONLY. TO USE ANY PLAN MORE THAN ONCE.AND TO AVOID ANY COPYRIGHT / LICENSE INFRINGEMENT, IT ISNECESSARY TO CONTACT PLAN SOURCE TO RECEIVE ARELEASE AND LICENSE FOR ANY EXTENDED USAGE. WHEREAS APURCHASER OF REPRODUCIBLE'S IS GRANTED A LICENSE TO MAKECOPIES, IT SHOULD BE NOTED THAT AS COPYRIGHTED MATERIALS,MAKING PHOTOCOPIES FROM CONSTRUCTION PLANS ISILLEGAL. COPYRIGHT AND LICENSING OF CONSTRUCTION PLANSEXIST TO PROTECT ALL PARTIES. IT RESPECTS AND SUPPORTS THEINTELLECTUAL PROPERTY OF THE ORIGINAL ARCHITECT ANDDESIGNER, THEREBY KEEPING IT POSSIBLE TO OFFER PREDRAWNPLANS AT AFFORDABLE PRICES. COPYRIGHT LAW FOR PREDRAWNCONSTRUCTION PLANS IS NOW BEING VIGOROUSLY ENFORCED.

GENERAL SITE NOTES1. CONTRACTOR TO VERIFY LOCATIONS OF SITE UTILITIES,REQUIREMENTS AND CONNECTIONS FEES. OWNER, CONTRACTOR,AND SUB-CONTRACTORS TO PAY ALL THEIR RELATEDCONSTRUCTION PERMIT FEES AS AGREED UPON BETWEEN THEOWNER AND CONTRACTOR.

2. BEFORE EXCAVATION, THE CONTRACTOR SHALL EXAMINE ALLDRAWINGS, MAPS, AND BUILDING SITE OF EXISTING FACILITY TODETERMINE THE ROUTES OF ALL UNDERGROUND UTILITIES. BEFOREDIGGING COMMENCES IT IS ADVISED THAT THE OWNER ORCONTRACTOR CALLS THEIR STATES UTILITY LOCATER FACILITATOR.

3. IT IS RECOMMENDED THAT THE SITES SOIL BE TESTED FORCOMPRESSION RATING TO DETERMINE FOUNDATION AND FOOTINGDESIGN. CONCRETE FOUNDATIONS AND FOOTING DESIGN SHALL BEACCORDANCE TO CHAPTER 4 OF THE I.R.C CODE. SEEFOUNDATION SECTION ON THIS PAGE FOR MORE DETAIL.

4. CONSULT A LOCAL CIVIL ENGINEER FOR SITE PLANS ANDSURVEYS OF EXISTING PROPERTY. A LANDSCAPE ARCHITECTSHOULD BE CONSULTED FOR MORE EXTENSIVE SITE LANDSCAPEDESIGNS.

I.R.C BUILDING PLANNING -CHAPTER 3

GLAZING R308R308.4 HAZARDOUS LOCATIONS

GLAZING IN THE FOLLOWING LOCATIONS SHALL BE OF SAFETYGLAZING CONFORMING TO THE HUMAN IMPACT LOADS OF SECTIONR308.3 (SEE EXCEPTIONS).

1. SWINGING DOORS EXCEPT JALOUSIES.2. FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLDDOOR ASSEMBLIES3. STORM DOORS4. UNFRAMED SWINGING DOORS5. DOORS AND ENCLOSURES FOR HOT TUB, WHIRLPOOLS,SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS AND IN ANYPORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTSWHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKINGSURFACE.6. FIXED OR OPERABLE VERTICAL PANELS ADJACENT TO A DOORWHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH ARCOF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGEIS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKINGSURFACE.7. INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSEDESCRIBED IN ITEMS 5 AND 6 ABOVE. THAT MEET ALL OF THEFOLLOWING CONDITIONS :

8. RAILING REGARDLESS OF AREA OR HEIGHT ABOVE A WALKINGSURFACE INCLUDING STRUCTURED BALUSTER PANELS ANDNONSTRUCTURAL IN-FILL PANELS.9. WALLS AND FENCES USED AS THE BARRIER FOR INDOOR ANDOUTDOOR SWIMMING POOLS , HOT TUBS AND SPAS WHEN :

60 INCHES ABOVE A WALKING SURFACE AND 60 INCHESHORIZONTALLY OF THE WATER'S EDGE.(THIS SHALL APPLY TOSINGLE GLAZING AND ALL PANELS IN MULTIPLE GLAZING)10. GLAZING ADJACENT TO STAIRWAYS,LANDINGS, AND APPROVEDRAMPS WITHIN 36 INCHES HORIZONTALLY OF A WALKING SURFACEWHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE.11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHESHORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANYDIRECTION WHEN EXPOSED SURFACE OF THE GLASS IS LESS THAN60 INCHES ABOVE THE NOSE OF THE TREAD.

MISC.A.I SKYLIGHT AND SLOPED GLAZING SHALL COMPLY WITHSECTION R308.6B.I SITE BUILT WINDOWS SHALL COMPLY WITH SECTION R308.5C.I EXTERIOR WINDOWS AND GLASS DOORS SHALL CONFORM TOTHE PROVISIONS OF SECTION R 613 AND THE FOLLOWING :

RESIST THE DESIGN WIND LOADS SPECIFIED IN TABLE R301.2(2)AND ADJUSTED FOR HEIGHT AND EXPOSURE PER TABLER301.2(3) (SECTION R613.2)D.I WINDOWS AND GLASS DOORS SHALL BE ANCHORED INACCORDANCE WITH THE PUBLISHED MANUFACTURER'SRECOMMENDATIONS. (SECTION R613.5.1)H.I ANCHORAGE OF EXTERIOR WINDOWS SHALL CONFORM TOSECTION R613.5.2

EMERGENCY ESCAPE AND RESCUE OPENINGR310R310 EMERGENCY ESCAPE RESCUE OPENINGS

BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALLHAVE AT LEAST ONE OPERABLE EMERGENCY AND RESCUE OPENING.SUCH OPENING SHALL OPEN DIRECTLY INTO A PUBLIC STREET,PUBLIC ALLEY, YARD OR COURT. WHERE BASEMENTS CONTAIN ONE ORMORE SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUEOPENINGS SHALL BE REQUIRED IN EACH SLEEPING ROOM. WHEREEMERGENCY ESCAPE AND RESCUE OPENINGSARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORETHAN 44 INCHES ABOVE THE FLOOR. WHERE A DOOR OPENINGHAVING A THRESHOLD BELOW THE ADJACENT GROUND ELEVATIONSERVES AS AN EMERGENCY ESCAPE AND RESCUE OPENING ANDIS PROVIDED WITH A BULKHEAD ENCLOSURE, THE BULKHEADENCLOSURE SHALL COMPLY WITH SECTION R310.3. THE NETCLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALLBE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCYESCAPE AND RESCUE OPENINGS FROM THE INSIDE. EMERGENCYESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHTBELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDEDWITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2.EMERGENCY ESCAPE AND RESCUE SHALL OPEN DIRECTLY INTO APUBLIC WAY. OR TO A YARD OR COURT THAT OPENS TO APUBLIC WAY.

MEANS OF EGRESS 311R311 MEANS OF EGRESS

STAIRWAYS, RAMPS, EXTERIOR EXIT BALCONIES, HALLWAYS ANDDOORS SHALL COMPLY WITH SECTION R311:1. STAIRWAY WIDTH SHALL NOT BE LESS THAN 36" IN CLEARWIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHTAND BELOW THE REQUIRED HEADROOM HEIGHT. (R311.7.1)2. THE MINIMUM HEADROOM IN ALL PARTS OF THE STAIRWAYSHALL NOT BE LESS THAN 6'-8". (R311.7.2)3. THE MAXIMUM RISER HEIGHT SHALL BE 7 3 /4". (R311.7.5.1)4. THE MINIMUM TREAD DEPTH SHALL BE 10". WINDER TREADSSHALL HAVE A MINIMUM TREAD DEPTH OF 6". (R311.7.5.2)

SMOKE ALARMS R314R314.3 LOCATION

SINGLE- AND MULTIPLE-STATION SMOKE ALARMS SHALL BEINSTALLED IN THE FOLLOWING LOCATIONS:1. EACH SLEEPING ROOM

R314.3 LOCATION - CONTINUED

2. OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITYOF THE BEDROOMS3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDINGBASEMENTS, CELLARS AND HABITABLE ATTICS BUT NOT INCLUDINGCRAWL SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS ORDWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN INTERVENINGDOOR BETWEEN THE ADJACENT LEVELS. A SMOKE ALARM INSTALLED ONTHE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWERLEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULLSTORY BELOW THE UPPER LEVEL.

WHEN ONE OR MORE SMOKE ALARMS IS REQUIRED TO BEINSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARMDEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THATTHE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THEALARMS IN THE INDIVIDUAL UNIT.

BUILDINGS AND STRUCTURES CONSTRUCTED IN WHOLE OR IN PARTIN FLOOD HAZARD AREAS (INCLUDING A OR V ZONES) ASESTABLISHED IN TABLE R301.2 (1) SHALL BE DESIGNED ANDCONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS CONTAINEDIN THIS SECTION

R322.1 GENERAL

R322.1.2 STRUCTURAL SYSTEMS

ALL STRUCTURAL SYSTEMS OF ALL BUILDING AND STRUCTURESSHALL BE DESIGNED, CONNECTED AND ANCHORED TO RESISTFLOTATION, COLLAPSE, OR PERMANENT LATERAL MOVEMENT DUETO STRUCTURAL LOADS AND STRESSES FROM FLOODING EQUAL TOTHE DESIGN FLOOD ELEVATION.

R322.1.4 ESTABLISHING THE DESIGN FLOOD ELEVATION

THE DESIGN FLOOD ELEVATION SHALL BE USED TO DEFINE AREASPRONE TO FLOODING, AND SHALL DESCRIBE. AT A MINIMUM. THEBASE FLOOD ELEVATION AT THE DEPTH OF PEAK ELEVATION OFFLOODING (INCLUDING WAVE HEIGHT) WHICH HAS A 1 PERCENT ORGREATER CHANCE OF BEING EQUALED TO EXCEEDED IN ANYGIVEN YEAR.

FOR DETERMINING DESIGN FLOOD ELEVATIONS AND IMPACTSREFER TO SECTION R322.1.4.1 AND R322.1.4.2

R322.1.6 PROTECTION OF MECHANICAL AND ELECTRICALSYSTEMS

ELECTRICAL SYSTEMS. EQUIPMENT AND COMPONENTS, ANDHEATING, VENTILATING, AIR CONDITIONING, AND PLUMBINGAPPLICATIONS. PLUMBING FIXTURES, DUCT SYSTEMS, AND OTHERSERVICE EQUIPMENT SHALL BE LOCATED AT OR ABOVE THEDESIGN FLOOD ELEVATION.

REVIEW EXCEPTIONS R322.1.6

ENCLOSED AREAS, INCLUDING CRAWL SPACES, THAT ARE BELOWTHE DESIGN FLOOD ELEVATION SHALL:1. BE USED SOLELY FOR PARKING OF VEHICLES, BUILDING ACCESSOR STORAGE.2. BE PROVIDED WITHFLOOD OPENING THAT MEET THEFOLLOWING CRITERIA:

R322.2.2 ENCLOSED AREA BELOW DESIGN FLOODELEVATION

A. THERE SHALL BE A MINIMUM OF TWO OPENINGS ONDIFFERENT SIDES OF EACH ENCLOSED AREA: IF ANY BUILDINGHAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOODELEVATION, EACH AREA SHALL HAVE OPENINGS ON EXTERIOR WALLS.B. THE TOTAL NET AREA OF ALL OPENINGS SHALL BE AT LEAST 1SQUARE INCH FOR EACH SQUARE FOOT OF ENCLOSED AREA, ORTHE OPENINGS SHALL BE DESIGNED AND THE CONSTRUCTIONDOCUMENTERS SHALL INCLUDE A STATEMENT THAT THE DESIGNAND INSTALLATION WILL PROVIDE FOR EQUALIZATION OFHYDROSTATIC FLOOD FORCES ON EXTERIOR WALLS BY ALLOWINGFOR AUTOMATIC ENTRY AND EXIT OF FLOODWATERS.C. THE BOTTOM OF EACH OPENING SHALL BE 1 FOOT OR LESSABOVE THE ADJACENT GROUND LEVEL.D. OPENING SHALL BEAT LEAST 3 INCHES IN DIAMETER.E. ANY LOVERS, SCREENS, OR OTHER OPENING COVERS SHALLALLOW THE AUTOMATIC FLOW OF FLOOD WATERS INTO AND OUTOF THE ENCLOSED AREA.F. OPENINGS INSTALLED IN DOORS AND WINDOWS, THAT MEETREQUIREMENTS A-E ARE ACCEPTABLE; HOWEVER, DOORS ANDWINDOWS WITHOUT INSTALLED OPENINGS DO NOT MEET THEREQUIREMENTS OF THE SECTION.

I.R.C. FOUNDATION - CHAPTER 4

GENERAL R401

R401 .2 REQUIREMENTS

FOUNDATION CONSTRUCTION SHALL BE CAPABLE OFACCOMMODATING ALL LOADS ACCORDING TO SECTION R301 ANDOF TRANSMITTING THE RESULTING LOADS TO THE SUPPORTINGSOIL. FILL SOILS THAT SUPPORT FOOTINGS AND FOUNDATIONSSHALL BE DESIGNED. INSTALLED, AND TESTED IN ACCORDANCEWITH ACCEPTED ENGINEERING PRACTICES. GRAVEL FILL USED ASFOOTINGS FOR WOOD AND PRECAST FOUNDATIONS SHALL COMPLYWITH SECTION R403.

R401 .3 DRAINAGE

SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWERCONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO ASTO NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAINSURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADESHALL FALL A MINIMUM OF 6 INCHES WITHIN THE FIRST 10FEET.

R401.4 SOIL TESTS

IN AREAS LIKELY TO HAVE EXPANSIVE. COMPRESSIBLE, SHIFTINGOR OTHER UNKNOWN SOIL CHARACTERISTICS. THE BUILDINGOFFICIAL SHALL DETERMINE WHETHER TO REQUIRE A SOIL TESTTO DETERMINE THE SOILS CHARACTERISTIC AT A PARTICULARLOCATION. THIS TEST SHALL BE MADE BY AN APPROVED AGENCYUSING AN APPROVED METHOD. CONTRACTOR TO REFER TO TABLER401.14.1 FOR PRESUMPTIVE LOAD - BEARING VALVES OFFOUNDATION MATERIALS.

MATERIALS R402

R402.1. WOOD FOUNDATIONSS

WOOD FOUNDATION SYSTEMS SHALL BE DESIGNED AND INSTALLEDIN ACCORDANCE WITH THE PROVISION OF THIS CODE.

R402.1.1 FASTENERS

FASTENERS USED BELOW APPROXIMATE GRADE (OR USED IN KNEE WALLCONSTRUCTION) SHALL BE OF TYPE 304 OR 316 STAINLESSSTEEL. FASTENERS USED ABOVE APPROXIMATE GRADE SHALL BE OF TYPE 304OR 316 STAINLESS STEEL, SILICON BRONZE, COPPER, HOT-DIPPEDGALVANIZED (ZINC COATED) STEEL NAILS. OR HOT TUMBLEDGALVANIZED (ZINC COATED) STEEL NAILS. ELECTROGALVANIZEDSTEEL NAILS AND GALVANIZED (ZINC COATED) STEEL STAPLESSHALL NOT BE PERMITTED.

R402.1.2 WOOD TREATMENT

ALL LUMBER AND PLYWOOD SHALL BE TREATED IN ACCORDANCEWITH AWPA U1 AND BEAR THE LABEL OF AN ACCREDITEDAGENCY.

R402.2 CONCRETE

CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVESTRENGTH AS SHOWN IN TABLE R402.2 (SECTION R402.2)CONCRETE SUBJECT TO WEATHERING (TABLE R301.2(1) SHALLBE AIR ENTRAINED AS SPECIFIED IN TABLE R402.2 (SECTIONR402.2) CONCRETE MIXTURES FOR GARAGE AND SUPPORT SLABSAND EXTERIOR LOCATIONS THAT WILL BE EXPOSED TO DEICINGCHEMICALS SHALL NOT HAVE MAXIMUM WEIGHT OF FLY ASH,SILICA FUME, SLAG OR OTHER POZZOLANS THAT EXCEED THEPERCENTAGE OF TOTAL WEIGHT OF CEMENTITIOUS MATERIALSSPECIFIED IN SECTION 4.2.3. OF ACI 318. MATERIALS USED TOPRODUCE CONCRETE AND TESTING THEREOF SHALL COMPLY WITHTHE APPLICABLE STANDARDS LISTED IN CHAPTER 3 OF ACI 318.

FOOTINGS R403

ALL EXTERIOR WALLS SHALL BE SUPPORTED ON CONTINUOUSSOLID OR FULLY GROUTED MASONRY OR CONCRETE FOOTINGS,CRUSHED STONE FOOTINGS, WOOD FOUNDATIONS OR OTHERAPPROVED STRUCTURAL SYSTEMS.

R403.1.1 MINIMUM SIZE

MINIMUM SIZE FOR CONCRETE AND MASONRY FOOTINGS SHALLBE AS SET FORTH IN TABLE R403.1 AND FIGURE R403.1(1)SPREAD FOOTING SHALL BE AT LEAST 6 INCHES IN THICKNESS.FOOTING PROJECTIONS SHALL BE AT LEAST 2 INCHES AND SHALLNOT EXCEED THE THICKNESS OF THE FOOTINGS. THE SIZE OF THEFOOTINGS SUPPORTING PIERS AND COLUMNS SHALL BE INACCORDANCE WITH TABLE R401.4.1 FOOTINGS FOR WOODFOUNDATIONS SHALL BE IN ACCORDANCE WITH THE DETAILS SETFORTH IN SECTION R403.2 AND FIGURES R403.1(2) ANDR403.1(3).

R403.1.2 CONTINUOUS FOOTING IN SEISMIC DESIGN CATEGORIESD0. D1. AND D2

THE BRACED WALL PANELS AT EXTERIOR WALLS OF ALLBUILDINGS AND ALL REQUIRED INTERIOR BRACED WALL PANELS INBUILDINGS WITH PLAN DIMENSIONS GREATER THAN 50 FEET INSEISMIC DESIGN CATEGORIES D0, D1, AND D2 SHALL BESUPPORTED BY CONTINUOUS FOOTINGS.

R403.1.3 SEISMIC REINFORCING

CONCRETE FOOTINGS LOCATED IN SEISMIC DESIGN CATEGORIESD0,D1,AND D2 AS ESTABLISHED IN TABLE R301.2(1) SHALLHAVE MINIMUM REINFORCEMENT SET FORTH IN THIS SECTION FORCONSTRUCTION JOINTS CREATED BETWEEN A CONCRETE FOOTINGAND A STEM WALL, WHERE A GROUTED MASONRY STEM WALL ISSUPPORTED ON A CONCRETE FOOTING AND STEM WALL. ANDWHEN MASONRY STEM WALLS WITHOUT SOLID GROUT ANDVERTICAL REINFORCEMENT ARE NOT PERMITTED

R403.1.4 MINIMUM DEPTH

ALL EXTERIOR FOUNDATIONS SHALL BE PLACED AT LEAST 12INCHES BELOW UNDISTURBED GROUND. WHERE APPLICABLE, THEDEPTH OF FOOTINGS SHALL ALSO CONFORM TO SECTIONSR403.1.4.1 THROUGH R403.1.4.2. EXCEPT FOR FROST-PROTECTED FOOTINGS, PERMANENT SUPPORT SHALL BECONSTRUCTED IN ACCORDANCE WITH SECTION R403.3.

INSEISMIC DESIGN CATEGORIES D0,D1 AND D2, INTERIORFOOTINGS SUPPORTING BEARING OR BRACING WALLS AND CASTMONOLITHICALLY WITH A SLAB ON APPROXIMATE GRADE SHALL EXTEND TO ADEPTH OF NOT LESS THAN 12 INCHES BELOW THE TOP OF THESLAB-SECTION R403.1.4.2

R403.1.5 SLOPE

FOOTINGS SHALL BE STEPPED WHERE IT IS NECESSARY TOCHANGE THE ELEVATION OF THE TOP SURFACE OF THE FOOTINGSOR WHERE THE SLOPE OF THE BOTTOM SURFACE OF THEFOOTING EXCEEDS ONE UNIT VERTICAL IN TEN UNITS HORIZONTAL(10-PERCENT SLOPE)

R403.1.6 FOUNDATION ANCHORAGE

THE WOOD SOLE PLATE AT EXTERIOR WALLS ON MONOLITHICSLABS AND WOOD SILL PLATE SHALL BE ANCHORED TO THEFOUNDATION WITH ANCHOR BOLTS SPACED A MAX. OF 6 FEET ONCENTER. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PLATESECTION. IN SEISMIC DESIGN CATEGORIES D0,D1,AND D2.ANCHOR BOLTS SHALL BE SPACED 6 FEET ON CENTER ANDLOCATED WITHIN 12 INCHES OF THE ENDS OF EACH PLATE

2015 INTERNATIONAL RESIDENTIAL CODE CONSTRUCTION SPECIFICATIONS AND METHODOLOGIES

3.5PER SECTION R324.3.5 ENCLOSED AREAS BELOW THE DESIGNFLOOD ELEVATION SHALL BE USED SOLELY FOR PARKING ORVEHICLES, BUILDING ACCESS OR STORAGE.

R403.1 GENERAL

FLOOD-RESISTANT CONSTRUCTION R322

GSPublisherVersion 70.0.88.79

DET

AIL

ED

DR

AFT

ING

&

DES

IGN

Sheet #:

DRAWN BY: DCB435-592-4287

C1.2

Revisions:

Dra

win

g D

ate:

1/4

/201

7Sc

ale:

As

Not

ed

Shee

t C

onte

nts:

IRC

SPE

CS

& M

ETH

OD

S

DET

AIL

ED

DRA

FTIN

G

&

DES

IGN

EX

PRES

SLY

RESE

RVES

IT

SC

OM

MO

N

LAW

C

OPY

RIG

HT

AN

D

OTH

ER

PRO

PERT

Y RI

GH

TSIN

HER

ENT

IN

THES

E PL

AN

S.

ALL

D

RAW

ING

S,

ELEC

TRO

NIC

FILE

S,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

ARE

INST

RUM

ENTS

O

F SE

RVIC

E A

ND

A

RE

THE

PRO

PERT

Y O

FD

ETA

ILED

D

RAFT

ING

&

D

ESIG

N

ALL

IN

FORM

ATI

ON

CO

NTA

INED

IN

TH

ESES

D

RAW

ING

S,

ELEC

TRO

NIC

FI

LES,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

IS

PRO

JEC

TSP

ECIF

IC

AN

D

SHA

LL

NO

T BE

RE

PRO

DU

CED

, D

ISC

LOSE

D,

CH

AN

GED

, O

R C

OPI

ED

WIT

HO

UT

FIRS

T O

BTA

ININ

G

THE

EXPR

ESS

WRI

TTEN

PE

RMIS

SIO

N

AN

D

CO

NSE

NT

OF

DET

AIL

ED D

RAFT

ING

& D

ESIG

N

FOR

CO

NST

RU

CT

ION

SET

55 N

600

E, S

T G

EOR

GE,

UT

8477

0W

WW

.DET

AIL

EDD

RA

FTIN

G.C

OM

SECTION AT INTERIOR BRACED WALL LINES WHEN REQUIRED BYSECTION R602.10.9 TO BE SUPPORTED ON A CONTINUOUSFOUNDATION. BOLTS SHALL BE AT LEAST 1/2 INCH IN DIAMETERAND SHALL EXTEND A MINIMUM OF 7 INCHES IN TO MASONRYOR CONCRETE.

INTERIOR BEARING WALL SOLE PLATES ON MONOLITHIC SLABFOUNDATION SHALL BE POSITIVELY ANCHORED WITH APPROVEDFASTENERS A NOT AND WASHER SHALL BE TIGHTENED ON EACHBOLT OF THE PLATE. SILLS AND SOLE PLATES SHALL BEPROTECTED AGAINST DECAY AND TERMITES WHERE REQUIREDBY SECTION R317 AND R318.

COLD-FORMED STEEL FRAMING SYSTEMS SHALL BE FASTENED TOTHE WOOD SILL PLATES OR ANCHORED DIRECTLY TO THEFOUNDATION AS REQUIRED IN SECTION R505.3.1 OR R603.3.1.

NOTE: CONSULT SECTION R403.1.6 FOR EXCEPTIONS ANDSECTION R403.1.6.1 ANCHORAGE METHODOLOGIES IN SEISMICDESIGN CATEGORIES C (LIGHT- FRAME TOWNHOUSES. D0. D1.AND D2.

R403.1.6 FOUNDATION ANCHORAGE - CONTINUE

R403.1.7 FOOTINGS ON OR ADJACENT TO SLOPES

THE PLACEMENT OF BUILDINGS AND STRUCTURES ON ORADJACENT TO SLOPES STEEPER THAN I UNIT VERTICAL IN 3UNITS HORIZONTAL (33.3 PERCENT SLOPE) SHALL CONFORM TOSECTIONS R403.1.7.1 THROUGH R403.1.7.4.

R403.1.8 FOUNDATIONS ON EXPANSIVE SOILS

FOUNDATIONS AND FLOOR SLABS FOR BUILDINGS LOCATED ONEXPANSIVE SOILS SHALL BE DESIGNED IN ACCORDANCE WITHSECTION 1808.6 OF THE INTERNATIONAL BUILDING CODE.

EXCEPTIONS: SLAB-ON-GROUND AND OTHER FOUNDATIONSSYSTEMS WHICH HAVE PERFORMED ADEQUATELY IN SOILCONDITIONS SIMILAR TO THOSE ENCOUNTERED AT THE BUILDINGSITE ARE PERMITTED SUBJECT TO THE APPROVAL OF THEBUILDING OFFICIAL.

EXPANSIVE SOILS SHALL BE DETERMINED PER SECTIONR403.1.8.1

R403.2 FOOTINGS FOR WOOD FOUNDATIONS

FOOTINGS FOR WOOD FOUNDATIONS SHALL BE IN ACCORDANCEWITH FIGURES R403.1(2) AND R403.1(3) AND HAVE A BASEAS DESCRIBED IN THIS SECTION.

R404.1 CONCRETE AND MASONRY FOUNDATION WALLS

FOR BUILDINGS WHERE THE MONTHLY MEAN TEMPERATURE OFTHE BUILDING IS MAINTAINED AT A MINIMUM OF 64 DEG.FOOTINGS ARE NOT REQUIRED TO EXTEND BELOW THE FROSTLINE WHEN PROTECTED FROM FROST BY INSULATION INACCORDANCE WITH FIGURE R403.3(1) AND TABLE R403.3(1).FOUNDATIONS PROTECTED FROM FROST IN ACCORDANCE TO SAIDFIGURES AND TABLES SHALL NOT BE USED FOR UNHEATEDSPACES SUCH AS PORCHES. UTILITY ROOM. GARAGES. ANDCARPORTS. AND SHALL NOT BE ATTACHED TO BASEMENTS ORCRAWL SPACES THAT ARE NOT MAINTAINED AT A MINIMUMMONTHLY MEAN TEMPERATURE OF 64 DEGREES FAHRENHEIT.

FOUNDATION AND RETAINING WALLS R404

R403.3 FROST PROTECTED SHALLOW FOUNDATIONS

FOUNDATION DRAINAGE R405

R405.1 CONCRETE OR MASONRY FOUNDATIONS

DRAINS SHALL BE PROVIDED AROUND ALL CONCRETE ORMASONRY FOUNDATIONS THAT RETAIN EARTH AND ENCLOSEHABITABLE OR USABLE SPACES LOCATED BELOW GRADE.DRAINAGE TILES, GRAVEL OR CRUSHED STONE DRAINS.PERFORATED PIPE OR OTHER APPROVED SYSTEMS OR MATERIALSSHALL BE INSTALLED AT OR BELOW THE AREA TO BE PROTECTEDAND SHALL DISCHARGE BY GRAVITY OR MECHANICAL MEANS INTOAN APPROVED DRAINAGE SYSTEM GRAVEL OR CRUSHED STONE-

R405.1 CONCRETE OR MASONRY FOUNDATIONS- CONTINUE

DRAINS SHALL EXTEND AT LEAST I FOOT BEYOND THE OUTSIDEEDGE OF THE FOOTING AND 6 INCHES ABOVE THE TOP OF THEFOOTING AND BE COVERED WITH AN APPROVED FILTERMEMBRANE MATERIAL. THE TOP OF THE OPEN JOINTS OF DRAINTILES SHALL BE PROTECTED WITH STRIPS OF BUILDING PAPER.DRAINAGE TILES OR PERFORATED PIPE SHALL BE PLACED ON AMINIMUM OF 2 INCHES OF WASHED GRAVEL OR CRUSHED ROCKAT LEAST ONE SIEVE SIZE LARGER THAN THE TILE JOINTOPENING OR PERFORATION AND COVERED NOT LESS THAN 6INCHES OF THE SAME MATERIAL.

OTHER THAN GROUP I SOILS, A SUMP SHALL BE PROVIDED TODRAIN THE POROUS LAYER AND FOOTINGS. AND SHALL COMPLYWITH SECTION R405.2.3.

FOUNDATION WATERPROOFING ANDDAMPPROOFING R406

R406.2 CONCRETE OR MASONRY FOUNDATION WATERPROOFING

1. FOUNDATION WALL WATERPROOFING SHALL BE WITH AMEMBRANE EXTENDING FROM THE TOP OF THE FOOTING TO THEFINISHED GRADE, WITH MATERIALS AS SPECIFIED IN SECTIONR406.2. EXCEPT WHERE REQUIRED TO BE WATERPROOFED.FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSEHABITABLE OR USABLE SPACES LOCATED BELOWAPPROXIMATE GRADE SHALL BE DAMPPROOFED.2. IN AREAS WHERE HIGH WATER TABLE OR OTHER SEVERE SOIL-WATER CONDITIONS ARE KNOWN TO EXIST. EXTERIOR FOUNDATIONWALLS THAT RETAIN EARTH AND ENCLOSE HABITABLE OR USABLESPACE LOCATED BELOW APPROXIMATE GRADE SHALL BEWATERPROOFED PER SECTION R406.2.3. DAMPPROOFING, WHERE REQUIRED, SHALL BE INSTALLED WITHMATERIALS AND AS REQUIRED IN SECTION R406.1.

UNDER-FLOOR SPACE R408

R408.1 VENTILATION

R408.2 OPENINGS FOR UNDER-FLOOR VENTILATION

VENTILATION OPENINGS SHALL BE COVERED FOR THE HEIGHTAND WIDTH WITH AN APPROVED MATERIAL LISTED IN THISSECTION.

R408.4 ACCESS

AN ACCESS OPENING 18 INCHES BY 24 INCHES SHALL BEPROVIDED TO THE UNDER FLOOR SPACE. ACCESS OPENINGS TOUNDERFLOOR SPACES WHERE MECHANICAL EQUIPMENT ISLOCATED SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONMI305.1.4.

R408.7 FLOOD RESISTANCE

FOR BUILDINGS LOCATED IN FLOOD HAZARD AREAS ASESTABLISHED IN TABLE R301.2(1)1. WALLS ENCLOSING THE UNDER - FLOOR SPACE SHALL BEPROVIDED WITH FLOOD OPENINGS IN ACCORDANCE WITH SECTIONR322.2.2.2. THE FINISHED GROUND LEVEL OF THE UNDER-FLOOR SPACESHALL BE EQUAL TO OR HIGHER THAN THE OUTSIDE FINISHEDGROUND LEVEL.EXCEPTIONS: UNDER-FLOOR SPACES THAT MEET THEREQUIREMENTS OF FEMA/FIA TB 11-1.

I.R.C. FLOORS - CHAPTER 5

R501.2 REQUIREMENTS

GENERAL R501

FLOOR CONSTRUCTION SHALL BE CAPABLE OF ACCOMMODATINGALL LOADS ACCORDING TO SECTION R301 AND OF TRANSMITTINGTHE RESULTING LOADS TO THE SUPPORTING STRUCTURALELEMENTS.

R502.2 DESIGN AND CONSTRUCTION

WOOD FLOOR FRAMING R502

FLOORS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCEWITH THE PROVISIONS OF THIS CHAPTER. FIGURE R502.2 ANDSECTIONS R317 AND R318 OR IN ACCORDANCE WITH AF&PA/NDS.

R502.2.1 FRAMING AT BRACED WALL LINES

A LOAD PATH FOR LATERAL FORCES SHALL BE PROVIDEDBETWEEN FLOOR FRAMING AND BRACED WALL PANELS LOCATEDABOVE OR BELOW A FLOOR AS SPECIFIED IN SECTIONR602.10.8

R502.3 ALLOWABLE JOIST SPANS

SPANS FOR FLOOR JOISTS SHALL BE IN ACCORDANCE WITHTABLES R502.3.1(1) AND R502.3.1(2).

R502.4 JOISTS UNDER BEARING PARTITIONS

JOISTS UNDER PARALLEL BEARING PARTITIONS SHALL BE OFADEQUATE SIZE TO SUPPORT THE LOAD. DOUBLE JOISTS. SIZED TOADEQUATELY SUPPORT THE LOAD. THAT AREA SEPARATED TOPERMIT THE INSTALLATION OF PIPING OR VENTS SHALL BE FULLDEPTH SOLID BLOCKED WITH LUMBER NOT LESS THAN 2 INCHES INNOMINAL THICKNESS SPACED NOT MORE THAN 4 FEET ONCENTER. BEARING PARTITIONS PERPENDICULAR TO JOISTS SHALLNOT BE OFFSET FROM THE SUPPORTING GIRDERS, WALLS, ORPARTITIONS MORE THAN THE JOIST DEPTH UNLESS SUCH JOISTSARE OF SUFFICIENT SIZE TO CARRY THE ADDITIONAL LOAD.

CONCRETE AND MASONRY FOUNDATION WALLS SHALL BESELECTED AND CONSTRUCTED IN ACCORDANCE WITHPROVISIONS OF SECTION R404 OR IN ACCORDANCE WITHACI 318. ACI 332. NCMA TR68-A OR ACI 530/ASCE 5/TMS402 OR OTHER APPROVED STRUCTURAL STANDARDS. WHEN ACI318. ACI 332 OR ACI 530/ASCE 5/TMS 402 OR THEPROVISION OF SECTION R404 IF THE IRC CODE ARE USED TODESIGN CONCRETE OR MASONRY FOUNDATION WALLS. PROJECTDRAWINGS. TYPICAL DETAILS AND SPECIFICATIONS ARE NOTREQUIRED TO BEAR THE SEAL OF AN ARCHITECT OR ENGINEER.UNLESS OTHERWISE REQUIRED BY THE STATE LAW OF THEJURISDICTION HAVING AUTHORITY. FOUNDATION WALLS THAT MEETALL OF THE FIVE PROVISIONS IN SECTION R404.1 SHALL BECONSIDERED LATERALLY SUPPORTED.

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

THE UNDER-FLOOR SPACE BETWEEN THE BOTTOM OF THE FLOORJOISTS AND THE EARTH UNDER ANY BUILDING (EXCEPT SPACEOCCUPIED BY A BASEMENT) SHALL HAVE VENTILATION OPENINGSTHROUGH FOUNDATION WALLS OR EXTERIOR WALLS. THE MINIMUMNET AREA OF VENTILATION OPENINGS SHALL NOT BE LESS THANI SQUARE FOOT FOR EACH 150 SQUARE FEET OF UNDER FLOORSPACE AREA. ONE SUCH VENTILATION OPENING SHALL BE WITHIN3 FEET OF EACH CORNER OF THE BUILDING.

R502.8 CUTTING, DRILLING AND NOTCHING

STRUCTURAL FLOOR MEMBERS SHALL NOT BE CUT, BORED, ORNOTCHED IN EXCESS OF THE LIMITATIONS SPECIFIED IN THISSECTION. SEE FIGURE R502.8.

I.R.C. WALL CONSTRUCTION -CHAPTER 6

WOOD WALL FRAMING R602R602.10 WALL BRACING

BUILDINGS SHALL BE BRACED IN ACCORDANCE WITH THIS SECTION OR,WHEN APPLICABLE, SECTION R602.12. WHERE A BUILDING DOES NOTCOMPLY WITH ONE OR MORE OF THE BRACING REQUIREMENTS IN THISSECTION, THOSE PORTIONS SHALL BE DESIGNED AND CONSTRUCTED INACCORDANCE WITH SECTION R301.1.

BRACED WALL PANEL CONSTRUCTION METHODS SHALL BE INACCORDANCE TO R602.10.2.

ALTERNATE BRACED WALL PANELS SHALL BE IN ACCORDANCE TOR602.10.2.

I.R.C. WALL COVERINGS-CHAPTER 7

R703.2 WATER-RESISTIVE BARRIER

EXTERIOR COVERING R703

ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM HOLES ANDBREAKS, COMPLYING WITH ASTM D 226 FOR TYPE I FELT OROTHER APPROVED WATER-RESISTIVE BARRIER SHALL BE APPLIEDOVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. SUCH FELTOR MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPERLAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2INCHES. WHERE JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESSTHAN 6 INCHES. THE FELT OR APPROVED MATERIAL SHALL BECONTINUOUS TO THE TOP OF THE WALLS AND TERMINATE ATPENETRATIONS AND THE BUILDING APPENDAGES IN A MANNERTO MEET THE REQUIREMENTS OF THE EXTERIOR WALL ENVELOPEAS DESCRIBED IN SECTION R703.1.

R703.7. EXTERIOR PLASTER

INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCEWITH ASTM C926 AND ASTM C 1063 AND THE PROVISIONS OFTHIS CODE.

R703.7.1 LATH

ALL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION-RESISTANT MATERIALS. EXPANDED METAL OR WOVEN WIRE LATHSHALL BE ATTACHED WITH 1 1/2 -INCH-LONG, 11 GAUGE NAILS,HAVING A 7/16-INCH HEAD, OR 7/8-INCH-LONG, 16-GAUGESTAPLES, SPACED NOT MORE THAN 6 INCHES, OR AS OTHERWISEAPPROVED.

R703.7.2 PLASTER

PLASTERING WITH PORTLAND CEMENT PLASTER SHALL BE NOTLESS THAN THREE COATS WHEN APPLIED OVER METAL LATH ORWIRE LATH AND SHALL BE NOT LESS THAN TWO COATS WHENAPPLIED OVER MASONRY, CONCRETE. PRESSURE-PRESERVATIVETREATED WOOD OR DECAY RESISTANT WOOD AS SPECIFIED INSECTION R317.1 OR GYPSUM BACKING. IF THE PLASTERSURFACE IS COMPLETELY CONCEALED. PLASTER APPLICATION NEEDBE ONLY TWO COATS, PROVIDED THE TOTAL THICKNESS IS SETFOURTH IN TABLE R702.1(1).

ON WOOD-FRAME CONSTRUCTION WITH AN ON-GRADE FLOOR SLABSYSTEM, EXTERIOR PLASTER SHALL BE APPLIED TO COVER, BUTNOT EXTEND BELOW, LATH, PAPER AND SCREED.

THE PROPORTION OF AGGREGATE TO CEMENTITIOUS MATERIALS

SHALL BE SET FOURTH IN TABLE R702.1(3).

R703.7.2.1 WEEP SCREEDS

A MINIMUM 0.019-INCH (No.26 GALVANIZED SHEET GAUGE).CORROSION-RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED,WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3 1/2INCHES SHALL BE PROVIDED AT OR BELOW THE FOUNDATIONPLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITHASTM C 926. THE WEEP SCREED SHALL BE PLACED A MINIMUMOF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE THEPAVED AREAS AND SHALL BE OF A TYPE THAT WILL ALLOWTRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING.THE WEATHER-RESISTANT BARRIER SHALL LAP THE ATTACHMENTFLANGE. THE EXTERIOR LATH SHALL COVER THE TERMINATE ONTHE ATTACHMENT FLANGE OF THE WEEP SCREED.

R703.7.3 WATER-RESISTIVE BARRIERS

WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED INSECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASEDSHEATHING SHALL INCLUDE A WATER-RESISTIVE VAPOR-PERMEABLE BARRIER WITH THE PERFORMANCE AT LEASTEQUIVALENT TO TWO LAYERS OF GRADE D PAPER.

R703.8.3 LINTELS-STONE VENEER

R703.8.4 ANCHORAGE-STONE VENEER

MASONRY VENEER SHALL BE ANCHORED TO THE SUPPORTINGWALL WITH CORROSION-RESISTANT METAL TIES WHERE VENEER ISANCHORED TO WOOD BACKINGS BY CORRUGATED SHEET METALTIES, THE DISTANCE SEPARATING THE VENEER FROM THESHEATHING MATERIAL SHALL BE A MAXIMUM OF A NOMINAL IINCH. WHERE THE VENEER IS ANCHORED TO WOOD BACKINGSUSING METAL STRAND WIRE TIES, THE DISTANCE SEPARATING THEVENEER FROM THE SHEATHING MATERIAL SHALL BE A MAXIMUMOF 4 1/2 INCHES EACH TIE SHALL BE SPACED NOT MORE THAN24" ON CENTER HORIZONTALLY AND VERTICALLY AND SHALLSUPPORT NOT MORE THAN 2.67 SQUARE FEET OF WALL AREA ASPER SECTION R703.7.4.1

I.R.C. ROOF-CLNG CONSTRUCTIONCHAPTER 8

GENERAL R801R801.2 REQUIREMENTS

ROOF AND CEILING CONSTRUCTION SHALL BE CAPABLE OFACCOMMODATING ALL LOADS IMPOSED ACCORDING TO SECTIONR301 AND OF TRANSMITTING THE RESULTING LOADS TO THESUPPORTING STRUCTURAL ELEMENTS.

WOOD ROOF FRAMING R802R802.3 FRAMING DETAILS

RAFTERS SHALL BE FRAMED TO RIDGE BOARD OR TO EACH OTHERWITH A GUSSET PLATE AS A TIE. RIDGE BOARD SHALL BE ATLEAST I-INCH NOMINAL THICKNESS AND NOT LESS IN DEPTH THANTHE CUT END OF THE RAFTER. AT ALL VALLEYS AND HIPS THERESHALL BE A VALLEY OR HIP RAFTER NOT LESS THAN 2-INCHNOMINAL THICKNESS AND NOT LESS IN DEPTH THAN THE CUT ENDOF THE RAFTER. HIP AND VALLEY RAFTERS SHALL BE SUPPORTEDAT THE RIDGE BY A BRACE TO A BEARING PARTITION OR BEDESIGNED TO CARRY AND DISTRIBUTE THE SPECIFIC LOAD AT THATPOINT. WHERE ROOF PITCH IS LESS THAN 3 UNITS VERTICAL IN12 UNITS HORIZONTAL. STRUCTURAL MEMBERS THAT SUPPORTRAFTERS AND CEILING JOISTS, SUCH AS RIDGE BEAMS, HIP ANDVALLEYS. SHALL BE DESIGNED AS BEAMS.

CEILING JOISTS AND RAFTER CONNECTORS AND LAPS SHALL BE INACCORDANCE TO SECTION R802.3.1 AND R802.3.2.

R802.4 ALLOWABLE CEILING JOIST SPANS

SPANS FOR CEILING JOISTS SHALL BE IN ACCORDANCE WITHTABLES R802.4(1) AND R802.4 (2). FOR OTHER GRADES ANDSPECIES AND FOR OTHER LOADING CONDITIONS. REFER TO AF&PASPAN TABLES FOR JOISTS AND RAFTERS.

R802.5 ALLOWABLE RAFTER SPANS

SPANS FOR RAFTERS SHALL BE IN ACCORDANCE WITH TABLESR802.5(1) AND R802.5.1(8). FOR OTHER GRADES ANDSPECIES AND FOR OTHER LOADING CONDITIONS. REFER TO AF&PASPAN TABLES FOR JOISTS AND RAFTERS. THE SPAN OF EACHRAFTER SHALL BE MEASURED ALONG THE HORIZONTALPROJECTION OF THE RAFTER.

R802.5.1 PURLINS

INSTALLATION OF PURLINS TO REDUCE THE SPAN OF RAFTERS ISPERMITTED AS SHOWN IN FIGURE R802.5.1. PURLINS SHALL BESIZED NO LESS THAN THE REQUIRED SIZE OF THE RAFTERS THATTHEY SUPPORT. PURLINS SHALL BE CONTINUOUS AND SHALL BESUPPORTED BY 2-INCH BY 4-INCH BRACES INSTALLED TOBEARING WALLS AT A SLOPE NO MORE THAN 45 DEGREES FROMTHE HORIZONTAL. THE BRACES SHALL BE SPACED NOT MORETHAN 4 FEET ON CENTREX AND THE UNBRACED LENGTH OFBRACES SHALL NOT EXCEED 8 FEET.

ROOF VENTILATION R806R806.1 VENTILATION REQUIRED

ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMEDWHERE CEILING ARE APPLIED DIRECTLY TO THE UNDERSIDE OFTHE ROOF RAFTER SHALL HAVE CROSS VENTILATION FOR EACHSEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINSTTHE ENTRANCE OF RAIN OR SNOW. VENTILATING OPENINGS SHALLBE PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WITH 1/16INCH MINIMUM TO 1/4 INCH MAXIMUM OPENINGS.

R806.2 MINIMUM VENT AREA

THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OFTHE AREA OF THE SPACE VENTILATED, EXCEPT THAT REDUCTIONOF THE TOTAL AREA TO 1/300 IS PERMITTED PROVIDED THAT ATLEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THEREQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORSLOCATED IN THE UPPER PORTION OF THE SPACE. UPPERVENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOWTHE RIDGE OR HIGHEST POINT OF THE SPACE MEASUREDVERTICALLY.

R806.3 VENT AND INSULATION CLEARANCE

WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATIONSHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF A I-INCH SPACE SHALL BE PROVIDED BETWEEN THE INSULATION ANDTHE ROOF SHEATHING AND AT THE LOCATION OF THE VENT.

ATTIC ACCESS R807

BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTIONSHALL HAVE AN ATTIC ACCESS OPENING TO ATTIC AREAS THATEXCEED 30 SQUARE FEET AND HAVE A VERTICAL HEIGHT OF 30INCHES OR MORE.

THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22INCHES BY 30 INCHES AND SHALL BE LOCATED IN A HALLWAYOR OTHER READILY ACCESSIBLE LOCATION. A 30 INCH MINIMUMUNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BEPROVIDED AT SOME POINT ABOVE THE ACCESS OPENING. SEESECTION M1305.1.3 FOR ACCESS REQUIREMENTS WHEREMECHANICAL EQUIPMENT IS LOCATED IN ATTICS.

R807.1 ATTIC ACCESS

MASONRY VENEER SHALL NOT SUPPORT ANY VERTICAL LOADOTHER THAN THE DEAD LOAD OF THE VENEER ABOVE. VENEERABOVE OPENINGS SHALL BE SUPPORTED ON LINTELS OFNONCOMBUSTIBLE MATERIALS AND THE ALLOWABLE SPAN SHALLNOT EXCEED THE VALUE SET FOURTH IN TABLE R703.7.3.1. THELINTELS SHALL HAVE A LENGTH OF BEARING NOT LESS THAN 4INCHES.

R502.3.3 FLOOR CANTILEVERS

FLOOR CANTILEVER SPANS SHALL NOT EXCEED THE NOMINALDEPTH OF THE WOOD FLOOR JOIST. FLOOR CANTILEVERSCONSTRUCTED IN ACCORDANCE WITH TABLE R502.3.3(1)SHALL BE PERMITTED WHEN SUPPORTING A LIGHT-FRAMEBEARING WALL OR ROOF ONLY.

R602.10.1 BRACED WALL LINES

FOR THE PURPOSE OF DETERMINING THE AMOUNT AND LOCATION OFBRACING REQUIRED IN EACH STORY LEVEL OF A BUILDING, BRACED WALLLINES SHALL BE DESIGNATED AS STRAIGHT LINES IN THE BUILDINGPLACED IN ACCORDANCE WITH THIS SECTION.

THE PROVISIONS OF THIS SECTION SHALL CONTROL THECONSTRUCTION OF EXTERIOR STRUCTURAL INSULATED PANEL (SIP)WALLS AND INTERIOR LOAD-BEARING SIP WALLS FOR BUILDINGS NOTGREATER THAN 60 FEET IN LENGTH PERPENDICULAR TO THE JOISTOR TRUSS SPAN, NOT GREATER THAN 40 FEET IN WIDTH PARALLELTO THE JOIST OR TRUSS SPAN AND NOT GREATER THAN TWOSTORIES IN HEIGHT WITH EACH WALL NOT GREATER THAN 10 FEETHIGH.

STRUCTURAL INSULATED PANEL WALLCONSTRUCTION R610R610.2 APPLICABILITY LIMITS

SIPS SHALL COMPLY WITH FIGURE R610.4 AND SHALL HAVE MINIMUMPANEL THICKNESS IN ACCORDANCE WITH TABLES R610.5(1) ANDR610.5(2) FOR ABOVE-GRADE WALLS. ALL SIPS SHALL BE IDENTIFIEDBY GRADE MARK OR CERTIFICATE OF INSPECTION ISSUED BY ANAPPROVED AGENCY.

R610.4 SIP WALL PANELS

GSPublisherVersion 70.0.88.79

DET

AIL

ED

DR

AFT

ING

&

DES

IGN

Sheet #:

DRAWN BY: DCB435-592-4287

A1.0

Revisions:

Dra

win

g D

ate:

1/4

/201

7Sc

ale:

As

Not

ed

Shee

t C

onte

nts:

MA

IN F

LOO

R PL

AN

DET

AIL

ED

DRA

FTIN

G

&

DES

IGN

EX

PRES

SLY

RESE

RVES

IT

SC

OM

MO

N

LAW

C

OPY

RIG

HT

AN

D

OTH

ER

PRO

PERT

Y RI

GH

TSIN

HER

ENT

IN

THES

E PL

AN

S.

ALL

D

RAW

ING

S,

ELEC

TRO

NIC

FILE

S,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

ARE

INST

RUM

ENTS

O

F SE

RVIC

E A

ND

A

RE

THE

PRO

PERT

Y O

FD

ETA

ILED

D

RAFT

ING

&

D

ESIG

N

ALL

IN

FORM

ATI

ON

CO

NTA

INED

IN

TH

ESES

D

RAW

ING

S,

ELEC

TRO

NIC

FI

LES,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

IS

PRO

JEC

TSP

ECIF

IC

AN

D

SHA

LL

NO

T BE

RE

PRO

DU

CED

, D

ISC

LOSE

D,

CH

AN

GED

, O

R C

OPI

ED

WIT

HO

UT

FIRS

T O

BTA

ININ

G

THE

EXPR

ESS

WRI

TTEN

PE

RMIS

SIO

N

AN

D

CO

NSE

NT

OF

DET

AIL

ED D

RAFT

ING

& D

ESIG

N

FOR

CO

NST

RU

CT

ION

SET

55 N

600

E, S

T G

EOR

GE,

UT

8477

0W

WW

.DET

AIL

EDD

RA

FTIN

G.C

OM

3'-0

"6'

-0"

3'-0

"6'

-0"

8'-0

"3'

-0"

14'-0

"8'

-0"

4'-6"4'-0"

6'-8

"3'

-0"

3'-0

"6'

-8"

5'-0

"2'

-0"

5'-0

"2'

-0"

5'-0

"2'

-0"

5'-0

"2'

-0"

9-0X

8-0

- OVE

RH

EAD

16-0X8-0 - OVERHEAD

6'-8

"2'

-4"

3'-0

"8'

-0"

5'-0

"3'

-0"

5'-0

"3'

-0"

5'-0

"3'

-0"

6'-8

"5'

-0"

5'-0

"3'

-0"

5'-0

"3'

-0"

5'-0"3'-0"

5'-0"3'-0"

3'-0"3'-0"

6'-8"2'-8"

6'-8"2'-6"

6'-8"2'-6"

3'-0

"2'

-0"

2'-0

"2'

-0"

2'-0

"2'

-0"

2'-6

"6'

-0"

4'-0

"6'

-0"

2'-6

"6'

-0"

6'-8

"2'

-6"

6'-8

"2'

-4"

2'-4

"6'

-8"

2'-4

"6'

-8"

2'-8

"6'

-8"

2'-0"3'-0"

6'-8

"2'

-8"

2'-4

"6'

-8"

2'-4

"6'

-8"

2'-4

"6'

-8"

2'-4

"6'

-8"

6'-8"3'-0"

6'-8"3'-0"

6'-0"4'-6"

3'-0"6'-0"

3'-0"6'-0"

3'-0"4'-6"

3'-0"4'-6"

8'-0"3'-0"

CO

ATS

BEN

CH

STUDY14'-10" x 11'-8"14'-10" x 11'-8"10'-0" Clg. Hgt.

FOYER7'-10" x 9'-8"7'-10" x 9'-8"

11'-0" Clg. Hgt.

ENTRY12' x 12'12' x 12'

14'-0" Clg. Hgt.

WH

W.I.C.13'-8" x 6'-2"13'-8" x 6'-2"

M. BATH12' x 13'-8"12' x 13'-8"

COUNTERDEPTH F.

DW

MASTER BEDROOM16'-2" x 19'-4"16'-2" x 19'-4"10'-0" Clg. Hgt.

BEDROOM #214'-9" x 11'-4"14'-9" x 11'-4"10'-0" Clg. Hgt.

BEDROOM #315'-6" x 13'-8"15'-6" x 13'-8"10'-0" Clg. Hgt.

COVERED PORCH39'-6" x 12'39'-6" x 12'

10'-0" Clg. Hgt.

COURT YARD22'-10" x 16'-4"22'-10" x 16'-4"

1 CAR GARAGE22'-4" x 12'-4"22'-4" x 12'-4"10'-0" Clg. Hgt.

2 CAR GARAGE19'-6" x 23'-8"19'-6" x 23'-8"10'-0" Clg. Hgt.

MECH.5'-10" x 5'-8"5'-10" x 5'-8"

DINING15'-2" x 14'-2"15'-2" x 14'-2"10'-0" Clg. Hgt.

KITCHEN15'-2" x 12'15'-2" x 12'

10'-0" Clg. Hgt.

GREAT ROOM22'-6" x 23'-10"22'-6" x 23'-10"12'-0" Clg. Hgt.

HALLWAY

SEAT

LOC

KER

SD

ESK

LIN

EN

76'-2

"

5'-8

"9'

-0"

7'-2

"9'

-8"

8'-1

0"

3'-6

"7'

-4"

12"

8'-6

"2'

-6"

6" 9'-11" 16'-9" 3'-6" 3'-6" 2'-10" 1'-6"

3'-8

"3'

-0"

3'-1

0"

1'-6"

2'-10" 5'-6" 2'-6" 6'-10" 3'-3" 3'-3" 3'-10" 2'-6" 16'-0" 2'-6" 16'-0" 2'-6"

67'-6"

70'-1

0"

72'-3/4"27'-4 3/4" 23'-4" 21'-4"

3'-1

0"

9'-6

"14

'-0"

3'-0

"7'

-0"

3'-0

"4'

-8"

4'-1

0"

3'-6

"3'

-0"

3'-1

0"

10'-8

"

4'-4" 3'-8" 4'-0" 4'-0" 3'-8" 3'-9" 3'-9"

5'-0

"4'

-8"

6'-8

"

2'-6" 11'-1" 2'-5"

3'-1

0"

1'-6"

8'-0

"1'-

0"

1'-6"

2'-6

"6'

-8"

4"

3'-3/4" 15'-4"6'-0" 3'-0" 4'-10" 1'-6"

12"6'-6"

12"

6'-0" 3'-4" 3'-4" 3'-4" 7'-4"

8'-4" 2'-10" 16'-0" 2'-6"2'

-2"

9'-0

"1'-

10"

4"2'

-0"

3'-1

0"

3'-6

"2'

-8"

5'-2

"5'

-6"

6"5'

-0"

4"

3'-3/4" 7'-2" 5'-0"

3'-3/4" 5'-10" 6'-4" 2'-2" 3'-8" 6'-6" 6'-4"

2'-4

"9'

-0"

1'-2"

4'-1

0"

6'-0

"13

'-6"

5'-4

"9'

-0"

6'-0

"6'

-6"

5'-2

"6'

-6"

5'-1

0"

6'-1

0"

8'-2"

10'-8" 10'-4" 6"

3'-1

0"

8'-8" 3'-4" 2'-0"

4'-6" 10'-10"

4" 20'-2" 2'-4" 15'-8"

3'-4

"3'

-0"

7'-6"

3'-8" 14'-4" 1'-2" 7'-10" 1'-2" 2'-3" 3'-0" 1'-3" 6'-6"

1'-4"

11'-6

"12

'-6"

5'-0

"

28'-0" 39'-6"

13'-0

"51

'-2"

12'-0

"

2A3.0

1A3.0

1A3.0

STRUCTURAL ENGINEER SHOULD BECONSULTED PRIOR TO CONSTRUCTION.

GENERAL STRUCTURAL NOTES

1. OWNER IS RESPONSIBLE TOVERIFY THIS HOUSE IS BUILT INCOMPLIANCE WITH ALL LOCALORDINANCES. DESIGNER ISNOT RESPONSIBLE FOR SITE CONDITIONSAND/OR THE USE OF THEDRAWINGS DURING CONSTRUCTION.

2. BUILDER MUST VERIFY ALL STRUCTURALELEMENTS FOR DESIGNAND SIZE WITH A LOCAL ENGINEERAND BUILDING OFFICIALS.

3. EXACT SPECIFICATION FOR ALL CONCRETEFOUNDATIONS (i.e. SIZE &REINFORCEMENT MUST BE DETERMINED BYLOCAL SOIL CONDITIONSAND ALL CODES THAT APPLY LOCALLY.VERIFY STRUCTURAL DESIGNWITH LOCAL ENGINEER.

4. STRUCTURAL LIABILITY: THE STRUCTURALFRAMING SYSTEMS (STRUCTURAL ELEMENTSSUCH AS BUT NOT LIMITED TO FOOTINGS,FOUNDATION WALLS, REINFORCEDCONCRETE, FRAMING WALLS,STRUCTURALLY INSULATED PANELWALLS & ROOF BEAMS,CONNECTIONS, HEADERS, JOISTS,RAFTERS AND TRUSSES), FORTHIS HOUSE IS FOR REFERENCEPURPOSE ONLY. A LOCAL

LIVING SPACE 2,900 Sq Ft

TOTAL 4,316 Sq Ft

SQUARE FOOTAGE

464 Sq FtBACK PORCH828 Sq FtGARAGE

124 Sq FtCOVERED ENTRY

SCALE: 1/4" = 1'-0"1 MAIN FLOOR PLAN

GSPublisherVersion 70.0.88.79

DET

AIL

ED

DR

AFT

ING

&

DES

IGN

Sheet #:

DRAWN BY: DCB435-592-4287

A1.1

Revisions:

Dra

win

g D

ate:

1/4

/201

7Sc

ale:

As

Not

ed

Shee

t C

onte

nts:

ROO

F &

SIT

E PL

AN

DET

AIL

ED

DRA

FTIN

G

&

DES

IGN

EX

PRES

SLY

RESE

RVES

IT

SC

OM

MO

N

LAW

C

OPY

RIG

HT

AN

D

OTH

ER

PRO

PERT

Y RI

GH

TSIN

HER

ENT

IN

THES

E PL

AN

S.

ALL

D

RAW

ING

S,

ELEC

TRO

NIC

FILE

S,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

ARE

INST

RUM

ENTS

O

F SE

RVIC

E A

ND

A

RE

THE

PRO

PERT

Y O

FD

ETA

ILED

D

RAFT

ING

&

D

ESIG

N

ALL

IN

FORM

ATI

ON

CO

NTA

INED

IN

TH

ESES

D

RAW

ING

S,

ELEC

TRO

NIC

FI

LES,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

IS

PRO

JEC

TSP

ECIF

IC

AN

D

SHA

LL

NO

T BE

RE

PRO

DU

CED

, D

ISC

LOSE

D,

CH

AN

GED

, O

R C

OPI

ED

WIT

HO

UT

FIRS

T O

BTA

ININ

G

THE

EXPR

ESS

WRI

TTEN

PE

RMIS

SIO

N

AN

D

CO

NSE

NT

OF

DET

AIL

ED D

RAFT

ING

& D

ESIG

N

FOR

CO

NST

RU

CT

ION

SET

55 N

600

E, S

T G

EOR

GE,

UT

8477

0W

WW

.DET

AIL

EDD

RA

FTIN

G.C

OM

4:12 SLOPE

4:12

SLO

PE

4:12

SLO

PE

4:12

SLO

PE

4:12 4:12

4:12

4:12

4:12

4:12

4:12

4:12 4:12

4:12

4:12

4:12

4:12

4:12 4:12

4:12

4:12

2375 EAST STREET

5475

EAS

T ST

REET25

' SET

BACK

LIN

E

10' S

ETBA

CK L

INE

10' SETBACK LINE

25' SETBACK LIN

E

FUTUREPOOL HOUSE

40'X40'FUTUREPOOL14'X20'

4:12 SLOPE

4:12

SLO

PE

4:12

SLO

PE

4:12

SLO

PE

4:12 4:12

4:12

4:12

4:12

4:12

4:12

4:12 4:12

4:12

4:12

4:12

4:12

4:12 4:124:12

4:12

1A3.0

SCALE: 1" = 20'1 SITE PLAN

SCALE: 1/4" = 1'-0"2 ROOF PLAN

GSPublisherVersion 70.0.88.79

DET

AIL

ED

DR

AFT

ING

&

DES

IGN

Sheet #:

DRAWN BY: DCB435-592-4287

A2.0

Revisions:

Dra

win

g D

ate:

1/4

/201

7Sc

ale:

As

Not

ed

Shee

t C

onte

nts:

EXTE

RIO

R EL

EVA

TIO

NS

DET

AIL

ED

DRA

FTIN

G

&

DES

IGN

EX

PRES

SLY

RESE

RVES

IT

SC

OM

MO

N

LAW

C

OPY

RIG

HT

AN

D

OTH

ER

PRO

PERT

Y RI

GH

TSIN

HER

ENT

IN

THES

E PL

AN

S.

ALL

D

RAW

ING

S,

ELEC

TRO

NIC

FILE

S,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

ARE

INST

RUM

ENTS

O

F SE

RVIC

E A

ND

A

RE

THE

PRO

PERT

Y O

FD

ETA

ILED

D

RAFT

ING

&

D

ESIG

N

ALL

IN

FORM

ATI

ON

CO

NTA

INED

IN

TH

ESES

D

RAW

ING

S,

ELEC

TRO

NIC

FI

LES,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

IS

PRO

JEC

TSP

ECIF

IC

AN

D

SHA

LL

NO

T BE

RE

PRO

DU

CED

, D

ISC

LOSE

D,

CH

AN

GED

, O

R C

OPI

ED

WIT

HO

UT

FIRS

T O

BTA

ININ

G

THE

EXPR

ESS

WRI

TTEN

PE

RMIS

SIO

N

AN

D

CO

NSE

NT

OF

DET

AIL

ED D

RAFT

ING

& D

ESIG

N

FOR

CO

NST

RU

CT

ION

SET

55 N

600

E, S

T G

EOR

GE,

UT

8477

0W

WW

.DET

AIL

EDD

RA

FTIN

G.C

OM

SCALE: 3/8" = 1'-0"1 FRONT ELEVATION

SCALE: 3/8" = 1'-0"2 LEFT ELEVATION

GSPublisherVersion 70.0.88.79

DET

AIL

ED

DR

AFT

ING

&

DES

IGN

Sheet #:

DRAWN BY: DCB435-592-4287

A2.1

Revisions:

Dra

win

g D

ate:

1/4

/201

7Sc

ale:

As

Not

ed

Shee

t C

onte

nts:

EXTE

RIO

R EL

EVA

TIO

NS

DET

AIL

ED

DRA

FTIN

G

&

DES

IGN

EX

PRES

SLY

RESE

RVES

IT

SC

OM

MO

N

LAW

C

OPY

RIG

HT

AN

D

OTH

ER

PRO

PERT

Y RI

GH

TSIN

HER

ENT

IN

THES

E PL

AN

S.

ALL

D

RAW

ING

S,

ELEC

TRO

NIC

FILE

S,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

ARE

INST

RUM

ENTS

O

F SE

RVIC

E A

ND

A

RE

THE

PRO

PERT

Y O

FD

ETA

ILED

D

RAFT

ING

&

D

ESIG

N

ALL

IN

FORM

ATI

ON

CO

NTA

INED

IN

TH

ESES

D

RAW

ING

S,

ELEC

TRO

NIC

FI

LES,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

IS

PRO

JEC

TSP

ECIF

IC

AN

D

SHA

LL

NO

T BE

RE

PRO

DU

CED

, D

ISC

LOSE

D,

CH

AN

GED

, O

R C

OPI

ED

WIT

HO

UT

FIRS

T O

BTA

ININ

G

THE

EXPR

ESS

WRI

TTEN

PE

RMIS

SIO

N

AN

D

CO

NSE

NT

OF

DET

AIL

ED D

RAFT

ING

& D

ESIG

N

FOR

CO

NST

RU

CT

ION

SET

55 N

600

E, S

T G

EOR

GE,

UT

8477

0W

WW

.DET

AIL

EDD

RA

FTIN

G.C

OM

SCALE: 3/8" = 1'-0"1 RIGHT ELEVATION

SCALE: 3/8" = 1'-0"2 REAR ELEVATION

GSPublisherVersion 70.0.88.79

DET

AIL

ED

DR

AFT

ING

&

DES

IGN

Sheet #:

DRAWN BY: DCB435-592-4287

A3.0

Revisions:

Dra

win

g D

ate:

1/4

/201

7Sc

ale:

As

Not

ed

Shee

t C

onte

nts:

BUIL

DIN

G S

ECTI

ON

S

DET

AIL

ED

DRA

FTIN

G

&

DES

IGN

EX

PRES

SLY

RESE

RVES

IT

SC

OM

MO

N

LAW

C

OPY

RIG

HT

AN

D

OTH

ER

PRO

PERT

Y RI

GH

TSIN

HER

ENT

IN

THES

E PL

AN

S.

ALL

D

RAW

ING

S,

ELEC

TRO

NIC

FILE

S,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

ARE

INST

RUM

ENTS

O

F SE

RVIC

E A

ND

A

RE

THE

PRO

PERT

Y O

FD

ETA

ILED

D

RAFT

ING

&

D

ESIG

N

ALL

IN

FORM

ATI

ON

CO

NTA

INED

IN

TH

ESES

D

RAW

ING

S,

ELEC

TRO

NIC

FI

LES,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

IS

PRO

JEC

TSP

ECIF

IC

AN

D

SHA

LL

NO

T BE

RE

PRO

DU

CED

, D

ISC

LOSE

D,

CH

AN

GED

, O

R C

OPI

ED

WIT

HO

UT

FIRS

T O

BTA

ININ

G

THE

EXPR

ESS

WRI

TTEN

PE

RMIS

SIO

N

AN

D

CO

NSE

NT

OF

DET

AIL

ED D

RAFT

ING

& D

ESIG

N

FOR

CO

NST

RU

CT

ION

SET

55 N

600

E, S

T G

EOR

GE,

UT

8477

0W

WW

.DET

AIL

EDD

RA

FTIN

G.C

OM

10'-0

"APP

RO

X. 1

7'-0

"

FLOOR

BEARING

RIDGE

10'-0

"

12'-0

"

APP

RO

X. 1

7'-0

"

KITCHEN / DININGGREAT ROOM

STOR.BATHHALLW.I.C.

FLOOR

BEARING

RIDGE

1" AIR SPACE MIN.

2X FACIA

ALUMINUM SOFFIT

1/2" (MIN.) CDX PLYWOOD SHEATHING

2X FRAMED WALL

STUCCO OR SIDING EXTERIOR FINISH

DRYWALLDRYWALL

PRE-ENGINEERED ROOF TRUSS

R-32 ATTIC INSULATION

CDX PLYWOOD ROOF SHEATING

FIBERGALLS COMP. SHINGLESOR METAL ROOFING

2x BLOCKING

INSULATION BAFFLE

FOOTING BELOW FROST DEPTH

GRADE - SLOPE 5% TO10'-0" AWAY FROM BLDG.

SLAB-ON-GRADE

P.T. PLATE W/ ANCHOR BOLT AS REQ'D

J-METAL WEEP SCREED

R-19 WALL INSULATION

10'-0

"

APP

RO

X. 1

7'-0

"

10'-0

"APP

RO

X. 1

7'-0

"

HALLWAY STUDYMASTER BEDROOM COURT YARD 1 CAR GARAGESTOR.

FLOOR

BEARING

RIDGE

0"

10'

17'-9 1/4"

SCALE: 1/4" = 1'-0"1 BUILDING SECTION #2

SCALE: 1/2" = 1'-0"3 TYPICAL WALL SECTION

SCALE: 1/4" = 1'-0"2 BUILDING SECTION

GSPublisherVersion 70.0.88.79

DET

AIL

ED

DR

AFT

ING

&

DES

IGN

Sheet #:

DRAWN BY: DCB435-592-4287

A4.0

Revisions:

Dra

win

g D

ate:

1/4

/201

7Sc

ale:

As

Not

ed

Shee

t C

onte

nts:

ELEC

TRIC

AL

PLA

N

DET

AIL

ED

DRA

FTIN

G

&

DES

IGN

EX

PRES

SLY

RESE

RVES

IT

SC

OM

MO

N

LAW

C

OPY

RIG

HT

AN

D

OTH

ER

PRO

PERT

Y RI

GH

TSIN

HER

ENT

IN

THES

E PL

AN

S.

ALL

D

RAW

ING

S,

ELEC

TRO

NIC

FILE

S,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

ARE

INST

RUM

ENTS

O

F SE

RVIC

E A

ND

A

RE

THE

PRO

PERT

Y O

FD

ETA

ILED

D

RAFT

ING

&

D

ESIG

N

ALL

IN

FORM

ATI

ON

CO

NTA

INED

IN

TH

ESES

D

RAW

ING

S,

ELEC

TRO

NIC

FI

LES,

FIEL

D

NO

TES

AN

D

ASS

OC

IATE

D

DO

CU

MEN

TS

IS

PRO

JEC

TSP

ECIF

IC

AN

D

SHA

LL

NO

T BE

RE

PRO

DU

CED

, D

ISC

LOSE

D,

CH

AN

GED

, O

R C

OPI

ED

WIT

HO

UT

FIRS

T O

BTA

ININ

G

THE

EXPR

ESS

WRI

TTEN

PE

RMIS

SIO

N

AN

D

CO

NSE

NT

OF

DET

AIL

ED D

RAFT

ING

& D

ESIG

N

FOR

CO

NST

RU

CT

ION

SET

55 N

600

E, S

T G

EOR

GE,

UT

8477

0W

WW

.DET

AIL

EDD

RA

FTIN

G.C

OM

CO

ATS

BEN

CH

WH

COUNTERDEPTH F.

DW

SEAT

LOC

KER

SD

ESK

LIN

EN

S SS

GFI

S.D.

S.D.

S.D.

S.D.

S.D.

S.D.

C.O.

S SS

S SS

S

S

S

S

SSS

SSS

SS

SS

S S

S S S

S

S

S

SS

S

S

SS

S

S S

SS

SS

S GFI

GFIGFIGFI

GFI

GFI

GFI

GFI

GFI

GFI

GFI

2.

A. Refrigerator F. Kitchen Hood K.Dryer B. Ovens G. Cooktop C. Garbage Disposal H. Furnace D. Dishwasher I. Spa Equipment E. Microwave J. Washing Machine

1.

ELECTRICAL

3.

4.

5.

6.

7.

8.

9.

10.

ELECTRICAL INFORMATION PROVIDED ON THESE PLANS ARE FOR DESIGNPURPOSES ONLY. FOR POWER AND CABLING DISTRIBUTION, CIRCUITINGAND CIRCUIT LOADS AND ALL RELATED INFORMATION CONCERNINGELECTRICAL WORK REFER TO ELECTRICAL SUB-CONTRACTORS.ELECTRICAL WORK TO CONFORM TO ALL LOCAL AND STATE LAWS AND TOBE PERFORMED BY A LICENSED ELECTRICIAN.ALL LIGHTING CIRCUITS SHALL BE CIRCUITS DEDICATED TO LIGHTINGONLY.SMOKE DETECTORS SHALL BE CONNECTEDTO A LIGHTING CIRCUIT. TO BE 110V WITHBATTERY BACKUP AND ARE AUDIBLE IN ALL SLEEPING AREAS.AT ALL BATHROOMS ONE 20 AMP BRANCH CIRCUIT SHALL SUPPLY ALLBATHROOM WALL OR COUNTER-TOP OUTLETS ONLY.PROVIDE TWO 20 AMP BRANCH CIRCUITS TO THE KITCHEN. THESECIRCUITS SHALL BE LIMITED TO SUPPLYING WALL AND COUNTER SPACEOUTLETS WITHIN THE KITCHEN. THESE CIRCUITS SHALL NOT BE USED FORLARGE APPLIANCES.ALL BEDROOM ELECTRICAL RECEPTACLES SHALL BE OF THE ARC-FAULTCIRCUIT INTERRUPTER TYPE, TYP.THE FOLLOWING APPLIANCES SHALL BE ON A DEDICATED CIRCUIT:

A SEPARATE DEDICATED 20 AMP BRANCH CIRCUIT SHALL BE PROVIDED TOSUPPLY LAUNDRY RECEPTACLE OUTLET.

LIGHT FIXTURES IN TUB OR SHOWER ENCLOSURES SHALL HAVE "SUITABLEFOR DAMP LOCATIONS" LABEL. IF IN COMBINATION WITH EXHAUST FANFIXTURE, EXHAUST FAN MUST PROVIDE MINIMUM OF 5 AIR CHANGES PERHOUR.

ELECTRICAL GROUNDING SYSTEM SHALL BE PER ALL APPLICABLE CODES.CONTRACTOR AND/OR ELECTRICAL SUB-CONTRACTOR SHALL SELECTGROUNDING METHOD MOST COMPATIBLE WITH FOUNDATION SYSTEM.

FLOOD LIGHT

W.P.

S.D.

DUPLEX OUTLET

EXHAUST FAN

INCANDESCENT LIGHT

EMERGENCY LIGHT

GROUND FAULT INTERRUPT

HANGING LIGHT

UNDER CABINET LIGHT

4 BULB 4' FLOURESCENT LIGHT

FLOOR DUPLEX OUTLET

SWITCHED DUPLEX OUTLET

SMOKE & C.O. DETECTORC.O.

8' FLOURESCENT LIGHT

S

WALL MOUNT INCANDESCENT LIGHT

PLANTER FLOOD

SMOKE DETECTOR

PHOTO CELL

E

PH.C.

TELEVISIONTV

PHONE

DUPLEX OUTLET -GFI

DUPLEX OUTLET -

S.D.

220 OUTLET

SWITCH

C

CEILING FAN W/LIGHT KIT

CEILING FAN

COMPUTER OUTLET

ELECTRICAL KEY

PENDENT INCANDESCENT LIGHT

WEATHER PROTECTED

HEAT-LIGHT/FAN

EYEBALL RECESSED

PH.

VANITY LIGHT

2 BULB 4' FLOURESCENT LIGHT

RECESSED INCANDESCENT

SCALE: 1/4" = 1'-0"1 ELECTRICAL PLAN

GENERAL STRUCTURAL NOTES

GENERAL

1. Construction documents are valid for a single use at the project location and shall not be reused, copied, or reproduced

without written approval of the registered design professional in responsible charge.

2. General notes and typical details are provided as a supplement to the construction documents and apply where specific

notes and details are not available. Specific notes and structural details shall take precedence over general notes and

typical details. Structural requirements shown in the framing plans and in structural details shall take precedence over

structural notes indicated in architectural sections.

3. Printed dimensions shall take precedence over scales shown on construction documents. The registered design

professional in responsible charge does not warrant the accuracy of scaled dimensions.

4. Approval by the inspector does not imply approval by the registered design professional in responsible charge. Structural

specifications that are unclear or ambiguous shall be referred to the registered design professional in responsible charge

for interpretation or clarification.

5. The registered design professional in responsible charge assumes no liability for the accuracy, completeness, or code

compliance of architectural, electrical, mechanical, drainage, or other non-structural specifications.

6. Omissions in and conflicts between the various elements of the construction documents shall be brought to the immediate

attention of the registered design professional in responsible charge and shall be resolved by the same before proceeding

with any work involved.

7. Requests for substitutions shall be submitted in writing to the registered design professional in responsible charge and shall

include the reasons for the request and any cost differentials. Substitutions are not allowed unless approved in writing by

the registered design professional in responsible charge.

8. The contractor shall become familiar with all portions of the construction documents and shall insure that all subcontractors

are familiar with those portions pertaining to their area of work. The contractor shall verify all site conditions, dimensions,elevations, coordinate all doors, windows, non-bearing interior and exterior walls, elevations, slopes, stairs, curbs, drains,

recesses, depressions, railings, waterproofing, finishes, chamfer, kerfs, and so forth, and immediately notify the registered

design professional in responsible charge regarding actual conditions which are not in agreement with the construction

documents.

9. The contractor is responsible for the method, means, and sequence of all structural erection except when specifically noted

otherwise in the construction documents. The contractor shall provide temporary shoring and bracing, providing adequate

vertical and lateral support during erection. Shoring and bracing shall remain in place until all permanent members are

placed and all final connections are completed.

10. The contractor is responsible for standard connections, unless noted otherwise. The contractor shall obtain additional

assistance from the registered design professional in responsible charge for non-standard connections.

POST-INSTALLED ANCHORS

1. Epoxy adhesive anchoring systems:

1.1. Concrete: Hilti HIT-RE 500-SD (ICC ES ESR-2322) or Simpson SET-XP (ICC ES ESR-2508)

1.2. Masonry (grouted): Hilti HIT-HY 150-MAX (ICC ES ESR-1967) or Simpson SET (ICC ES ESR-1772)

1.3. The calculated strength of anchorage assumes the following conditions for installation: 7 day minimum age of

concrete, maximum short term concrete temperature= 150° F, maximum long term concrete temperature= 110° F, dry

concrete surface, and normal weight concrete. If conditions are otherwise, contact engineer for anchor specifications.

1.4. Steel reinforcement and rods shall be embedded 10 bar diameters unless noted otherwise in the structural drawings

and details. Where 10 bar diameters exceeds the member thickness minus minimum cover, steel reinforcement shall

be embedded the member thickness minus minimum cover with a standard hook.

1.5. Embedded portions of steel reinforcement and rods shall be clean, straight, and free of mill scale, rust and other

coatings that impair the bond with the adhesive. Reinforcement must not be bent after installation (ICC ES ESR-2322).

1.6. Installation of adhesive anchors shall be performed by personnel trained to install adhesive anchors.

2. Mechanical expansion anchors:

2.1. Concrete: Hilti KWIK BOLT TZ (ICC ES ESR-1917)

2.2. Masonry: Hilti KWIK BOLT 3 (ICC ES ESR-1385)

2.3. Expansion anchors shall not be used in tensile load applications (e.g. hold-downs, moment frames).

3. Post-installed anchoring systems shall be installed according to the Manufacture’s Printed Installation Instructions (MPII).

Hole cleaning method shall be based on drilling method and borehole conditions and shall conform to the manufacture’s

instructions.

SOIL AND FOUNDATIONS

1. Geotechnical investigations shall conform to 2015 IBC 1803. Excavation, grading and fill shall conform to 2015 IBC 1804.

Footings and foundations shall be constructed in accordance with 2015 IBC 1807 through 1810.

2. Where required, the owner shall submit a geotechnical investigation report to the building official in accordance with 2015

IBC 1803. The contractor shall inform the registered design professional in responsible charge if the soil conditions are not

consistent with the investigation report and the foundation design data.

3. Excavations for any purpose shall not remove lateral support from any footing or foundation without first underpinning or

protecting the footing or foundation against settlement or lateral translation (2015 IBC 1804.1).

4. Excavation outside the foundation shall be backfilled with soil that is free of organic material, construction debris, cobbles

and boulders or with soil that is a controlled low-strength material (CLSM). The backfill shall be placed in lifts and

compacted, in a manner that does not damage the foundation or the waterproofing or dampproofing material (2015 IBC

1804.3).

5. The ground immediately adjacent to the foundation shall have a 5-percent slope away from the building for a minimum

distance of 10 feet measured perpendicular to the face of the foundation wall. If physical obstructions or lot lines prohibit 10

feet of horizontal distance, a 5-percent slope shall be provided to an approved alternative method of diverting water away

from the foundation. Impervious surfaces within 10 feet of the building foundation shall have a minimum 2-percent slope

(2015 IBC 1804.4).

6. Footings and foundations shall be built on undisturbed soil, compacted fill material or CLSM. Compacted fill material and

CLSM shall conform to 2015 IBC 1804.6 and 2015 IBC 1804.7, respectively (2015 IBC 1809.2).

7. The top surface of the footings shall be level. The bottom surface of footings is permitted to have a maximum 10-percent

slope. Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the

surface of the ground has more than a 10-percent slope (2015 IBC 1809.3).

8. The minimum depth of footings below the undisturbed ground surface shall be 12 inches (2015 IBC 1809.4). Foundation

walls, piers and other permanent supports shall be extended below the frost line, except where otherwise protected from

frost (2015 IBC 1809.5).

9. The placement of footings on or adjacent to 33-percent slopes and steeper shall conform to 2015 IBC 1808.7.

10.Floors of basements shall be placed over base course not less than 4 inches in thickness and a drain shall be installed

around the foundation perimeter that consists of gravel or crushed stone containing not more than 10-percent material that

passes through a No. 4 sieve (2015 IBC 1805.4.1).

11.Backfill shall not be placed against a foundation wall until the wall has sufficient strength and is anchored to the floor above,

or is sufficiently braced to prevent damage by the backfill, except bracing is not required for walls supporting less than 4

feet of unbalanced backfill (R404.1.7).

CONCRETE

1. Concrete materials, quality control, and construction shall comply with 2015 IBC Chapter 19 and ACI 318-14.

2. Compressive strength (minimum specified at 28 days)

2.1. Footings: 3,000 psi (2015 IBC 1808.8.1)

2.2. Interior floor slabs on grade: 4,000 psi

2.3. Exterior floor slabs on grade: 4,000 psi

2.4. Suspended slabs: 4,000 psi

2.5. Walls: 3,000 psi (2015 IBC 1904.1) for R-2, R-3 occupancies and appurtenances

4,000 psi for other occupancies3. Materials

3.1. Cements (ASTM C 150). Concrete exposed to freezing and thawing or deicing chemicals shall conform to the

maximum water-cementitious material ratios and minimum compressive strength requirements of ACI 318-14 table

19.3.1.1

3.2. Aggregates (ASTM C 33): nominal maximum size of coarse aggregate shall not be larger than 1/5 the narrowest

dimension between forms, nor 1/3 the depth of slabs, nor 3/4 the minimum clear spacing between reinforcing bars or

wires, tendons, or ducts (ACI 318-14 26.4.2.1).

3.3. Water used in mixing concrete shall be potable, clean and free from injurious amounts of oils, acids, alkalis, salts,

organic materials, or other substances deleterious to concrete or reinforcement (ACI 318-14 26.4.1.3.1.b).

3.4. Admixtures shall be subject to prior approval by the registered design professional in responsible charge (ACI 318-14

26.4.1.4.1.b).

3.5. Concrete exposed to freezing and thawing or deicing chemicals shall be air-entrained with air content indicated in ACI

318-14 Table 19.3.3.1. Tolerance on air content as delivered shall be plus/minus 1.5 percent (Table ACI 318-14

19.3.3.1).

4. Steel Reinforcement

4.1. Deformed bars: fy = 60 ksi (ASTM A615)

4.2. Welded plain wire: fy = 60 ksi (ASTM A1064)

4.3. Deformed Bar Anchors (DBA) (ASTM A496)

4.4. Headed Stud Anchors (HSA) (ASTM A108)

4.5. At the time concrete is placed, reinforcement shall be free from mud, oil, or other nonmetallic coatings that decrease

bond (ACI 318-14 26.6.1.2).

4.6. Reinforcement shall be accurately placed and adequately supported before concrete is placed, and shall be secured

against displacement (ACI 318-14 26.6.2.2).

4.7. Details of reinforcement shall conform to ACI 318-14 Chapter 25.

5. Minimum concrete cover (ACI 318-14 Table 20.6.1.3.1)

5.1. Concrete cast against and exposed to earth: 3 inches

5.2. Concrete exposed to earth or weather:

5.2.1. No. 6 through No. 18 bars: 2 inches

5.2.2. No. 5 bar, W31 wire, and smaller: 1.5 inches

5.3. Concrete not exposed to earth or weather:

5.3.1. Slabs, walls, joists No. 11 bar and smaller: 0.75 inches

5.3.2. Beams, columns primary reinf., ties, stirrups: 1.5 inches

6. Formwork shall conform to ACI 318-14 Sections 26.11 and 26.12 and ACI 347. Forms shall be removed in a manner as not

to impair safety and serviceability of the structure. Concrete exposed by form removal shall have sufficient strength not to

be damaged by removal operation (ACI 318-14 26.11.2).

7. Conduits, pipes, and sleeves of any material not harmful to concrete and within the limitations of ACI 318-14 20.7 shall be

approved by the registered design professional in responsible charge (ACI 318-14 20.7).

8. Construction joints shall be so made and located as not to impair the strength of the structure (ACI 318-14 18.10.9).

9. The thickness of concrete floor slabs on grade shall not be less than 3.5 inches. A 6-mil polyethylene vapor retarder with

joints lapped not less than 6 inches (or an equivalent material) shall be placed between the base course or subgrade and

the concrete floor slab, except a vapor retarder is not required in detached utility buildings or other unheated facilities (2015

IBC 1907).

MASONRY

1. Masonry materials, construction, and quality shall conform to 2015 IBC 2103-2105, ACI 530-13, ACI 530.1-13

1.1. Compressive strength: f'c = 1,900 psi (ACI 530.1-13 1.4B.2 TABLE 2)

2. Concrete masonry units (CMU) (ASTM C 90)

2.1. Grade N

2.2. Comprehensive strength: f'm = 1,900 psi (ACI 530.1-13 1.4B.2 TABLE 2)

3. Mortar (ASTM C 270)

3.1. Type S Portland cement (ACI 530-13 7.4.4.2.2)

3.2. Compressive strength: f'c = 1,900 psi (ACI 530.1-13 1.4B.2 TABLE 2)

4. Grout (ASTM C 476)

4.1. Type: fine or coarse (2015 IBC 2103.3)

4.2. Compressive strength (minimum specified at 28 days): f'c = 2,000 psi (ASTM C 1019)

5. Steel reinforcement

5.1. Deformed bars: fy = 60 ksi (ASTM A 615 Gr. 60)

5.2. Deformed Bar Anchors (DBA) (ASTM A496)

5.3. Headed Stud Anchors (HSA) (ASTM A108)

6. Bed joint thickness shall be 5/8 inch maximum (2015 IBC 2105.2.2.1.2)

7. Grout shall have an 8”-11” slump using a 3/8” maximum aggregate. Grout lifts shall not exceed 5 feet in height unless noted

otherwise. Consolidate by mechanical vibration pours that exceed 12 inches in height.

8. The clear distance between parallel bars shall not be less than the nominal diameter of the bars, nor less than 1 inch (ACI

530-13 6.1.3). Joint reinforcement shall have cover not less than 5/8". (ACI 530-13 6.1.4.2)

9. The diameter of bend measured on the inside of reinforcing bars, other than for stirrups and ties, shall not be less than

specified in table 6.1.6 (ACI 530-13 6.1.6)

10. All masonry below grade shall be solid grouted.

11.Control joint spacing not to exceed 30'-0". See Architectural for locations.

MASONRY AND STONE VENEER

1. Masonry veneer materials, construction, and quailty shall conform to 2015 IBC 2103-2105 and ACI 530-13 Chap. 6.

2. Lintels

2.1. Veneer shall not support any vertical load other than the dead load of the veneer above. Veneer above openings shall

be supported on lintels of noncombustible materials. Lintels shall have 1 inch of bearing for each 1 foot of span, but not

less than 4 inches of bearing.

3. Anchorage

3.1. Veneer shall be anchored to the supporting wall framing with hot-dipped galvanized Hohmann & Barnard DW - 10HS

anchor system (or equivalent) metal ties.

3.2. Engage all anchor ties with a No. 9 gage wire in the center of the veneer and embedded in the mortar joint.

(R703.8.4.1)

3.3. Each tie shall be spaced not more than 16 inches on center horizontally and vertically and shall support not more than

2.67 square feet of wall area. Additional metal ties shall be provided around all wall openings greater than 16 inches in

either dimension. (R703.8.4.1)

WOOD

1. Wood materials, quality, and construction shall conform to 2015 IBC Chapter 23 and Table 2304.10.

2. Structural lumber (2015 IBC 2303.1.1-9, 2015 NDS)

2.1. Bearing walls: Douglas-Fir Larch (DF) Stud (ASTM D 1990, DOC PS 20)

2.2. Posts: Douglas-Fir Larch (DF) Stud (ASTM D 1990, DOC PS 20)

2.3. Beams and headers: Douglas-Fir Larch (DF) No. 2 (ASTM D 1990, DOC PS 20)

2.4. Heavy timber: Douglas-Fir Larch (DF) No. 1 (ASTM D 1990, DOC PS 20)

2.5. Sill plates: Preservative-treated wood, redwood (AWPA U1 M4)

2.6. Naturally durable or preservative-treated wood shall be used where structural lumber is 18 inches or closer to exposedground; where structural lumber is in contact with exterior masonry or concrete walls below grade; where sleepers,

sills, posts, and columns are on a concrete or masonry slab or footing that is in direct contact with earth; and wherestructural lumber is attached directly to exterior masonry or concrete walls, unless a 0.5 inch air space on top, sides,

and end is provided (2015 IBC 2304.12).

3. Structural logs (ASTM D 3957) - ICC - 400 standard for the design and construction of log structures

4. Structural glued-laminated timber (2015 IBC 2303.1.3,2015 NDS 5.1.1)

4.1. Single span: 24F-1.8E (24F-V4) (ASTM D 3737, ANSI/AITC A190.1)

4.2. Multiple span: 24F-1.8E Balanced layup (24F-V8) (ASTM D 3737, ANSI/AITC A190.1)

4.3. Cantilever span: 24F-1.8E Balanced layup (24F-V8) (ASTM D 3737, ANSI/AITC A190.1)

5. Structural composite lumber and engineered wood (2015 IBC 2303.1.10, 2015 NDS 8.1.1)

5.1. Laminated strand lumber (LSL)

5.1.1. Ex = 1.3E (ASTM D 5456)

5.1.2. Ex = 1.5E (ASTM D 5456)

5.1.3. Ex = 1.55E (ASTM D 5456)

5.1.4. 1.125 inch APA Performance-Rated (or equivalent) rim board - (2015 IBC 2303.1.13, ASTM 7672, ANSI/APA

PRR410)

5.2. Laminated veneer lumber (LVL)

5.2.1. Ex = 2.0E (ASTM D 5456)

5.3. Parallel strand lumber (PSL)

5.3.1. Ex = 2.0E (beams) (ASTM D 5456)

5.3.2. Ex = 1.8E (columns) (ASTM D 5456)

5.4. Prefabricated wood I-joist (2015 IBC 2303.1.2, 2015 NDS 7.1.1) (ASTM D 5055)

6. Wood structural panels (2015 IBC 2304.8, 2015 NDS 9.1.3)

6.1. Roof, floor, and wall sheathing: oriented strand board (OSB) (DOC PS 1,2).

6.2. Sheathing shall be manufactured with exterior glue and not less than 4X8 feet, except at boundaries and at changes in

framing (2015 IBC 2305.1, AWC SDPWS-2015).

6.3. Wall sheathing

6.3.1. Oriented strand board (OSB) (DOC PS 1,2)

6.3.2. All panel joints in walls shall occur over studs or blocking using a minimum of 8d common nails spaced a

maximum of 6 inches at panel edges and 12 inches at intermediate framing (2015 IBC 2306.3).

6.4. Roof and floor sheathing shall be placed perpendicular to supporting framing. Stagger sheathing joints.

7. Fasteners

7.1. Nails (2015 IBC 2303.6, 2015 NDS Table L4) (ASTM F 1667)

Pennyweight Common Box Sinker

7.1.1. 8d = 0.131" X 2.5" 0.113" X 2.5" 0.113" X 2.375"

7.1.2. 10d = 0.148" X 3.0" 0.128" X 3.0" 0.120" X 2.875"

7.1.3. 16d = 0.162" X 3.5" 0.135" X 3.5" 0.148" X 3.250"

7.1.4. 20d = 0.192" X 4.0" 0.148" X 4.0" 0.177" X 3.750"

7.1.5. 30d = 0.207" X 4.5" 0.148" X 4.5" 0.192" X 4.250"

7.2. Staples (2015 IBC 2303.6, 2306.3)

7.2.1. 16 gage = 1.5X0.4375 inch crown (ASTM F 1667)

7.3. Bolts (2015 NDS 12.1.3, Table L1)

7.3.1. Connector bolts (A307)

7.3.2. Anchor bolts (A307) with a 3X3X0.229 inch washer (2015 IBC 2308.12.8) and 7" min embedment.

7.3.3. Bolt holes shall be drilled with a bit 1/32 inch to 1/16 inch larger than the nominal bolt diameter.

7.4. Lag Screws (2015 NDS 12.1.4, Table L2) (A307)

7.4.1. Lag screws shall be inserted in a drilled pilot hole that is 60%-75% of the shank diameter by turning with a

wrench. Do not drive screws with a hammer. Lag screws shall be provided with an oversized washer .

7.5. Fasteners in preservative-treated and fire-retardant-treated wood shall be of hot dipped zinc-coated galvanized steel,

silicon bronze or copper (2015 IBC 2304.10.5).

7.6. Sheathing fasteners shall be driven so the head or crown is flush with the sheathing surface (2015 IBC 2304.10.2).

8. Joist hangers and connectors (2015 IBC 2303.5)

8.1. Hanger hardware and other wood connections shall be designed to carry the capacity of the supporting members.

9. Floor framing (2015 IBC 2308.4.2)

9.1. Joists shall not have less than 1.5 inches of bearing on wood or metal, or less than 3 inches on masonry (2015 IBC

2308.4.2.2). Pre-fabricated wood I-joists shall have minimum bearing according to the manufacture's

recommendations and specifications.

9.2. Joists shall be supported laterally at the ends and at each support by full-depth solid blocking, except where nailed to a

header. Solid blocking shall not be less than 2 inches thick (2015 IBC 2308.4.2.3).

9.3. Where the nominal depth-to-thickness ratio of the framing member exceeds 6:1, there shall be one line of bridging for

each 8 feet of span. Bridging shall consist of not less than 1X3 inch lumber, metal bracing, or full-depth solid blocking

(2015 IBC 2308.4.6).

9.4. Notches on the ends of joists shall not exceed one-fourth the joist depth. Holes bored in joists shall not be within 2

inches of the top or bottom of the joist. Notches in the top or bottom of joists shall not exceed one-sixth the depth and

shall not be located in the middle third of the span (2015 IBC 2308.4.2.4).

9.5. The diameter of holes bored or cut into structural floor members shall not exceed one-third the depth of the member.

Holes shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member.

Where the member is also notched, the hole shall not be closer than 2 inches to the notch (R502.8.1).

10. Wall construction (2015 IBC 2308.5)

10.1.Studs shall be placed with their wide dimension perpendicular to the wall. Not less than three studs shall be

installed at each corner of an exterior wall (2015 IBC 2308.5.2).

10.2.Bearing and exterior wall studs shall be capped with 2-inch thick nominal double top plates, have a width at least

equal to the width of the studs, and shall be installed to provide overlapping at corners and intersections with other

partitions. End joints in partitions shall be offset at least 48 inches, and shall be nailed with not less than eight 16d

common face nails on each side of the joint. Plates shall have a width at least equal to the width of the studs (2015

IBC 2308.5.3.2).10.3.In nonbearing walls and partitions studs shall be capped with no less than a single top plate installed to provide

overlapping at corners and at intersections with other walls and partitions. The plate shall be continuously tied at joints

by solid blocking at least 16 inches in length and equal in size to the plate or metal ties with spliced sections fastened

on each side of the joint (2015 IBC 2308.5.4).

10.4.Studs shall have full bearing on a 2-inch thick nominal (or larger) bottom plate or sill having a width at least equal to

the width of the stud (2015 IBC 2308.5.3.1).

10.5.Bearing partitions parallel to joists shall be supported on beams, girders, doubled joists, walls or other bearing

partitions. Bearing partitions perpendicular to joists shall not be offset from supporting girders, walls or partitions more

than the joist depth unless noted otherwise (2015 IBC 2308.4.5).

10.6.In exterior walls and bearing partitions, any wood stud is permitted to be cut or notched to a depth not exceeding 25

percent of its width. In nonbearing partitions, cutting or notching of studs to a depth of not greater than 40 percent of

the width is permitted (2015 IBC 2308.5.9).

10.7.A hole with a diameter not greater than 40 percent of the stud width is permitted to be bored in any wood stud. In

no case shall the edge of the bored hole be nearer than 0.625 inches to the edge of the stud. Bored holes shall not be

located at the same section of stud as a cut or notch (2015 IBC 2308.5.10).

10.8.Bearing walls without wood sheathing or gypsom wall board on either side shall have blocking between wall studsat mid-height.

11.Posts and columns

11.1.Columns shall be as wide as the member they support, laterally supported at all floor levels, and extend down

through the structure to the foundation. Provide squash blocking at rim joist below all columns, trimmers, and posts.

11.2.Wood columns and posts shall be framed to provide full end bearing (2015 IBC 2304.10.7).

11.3.Posts and columns shall be supported by concrete piers or metal pedestals projecting above concrete or masonry

floors or decks exposed to weather or water splash, or in basements, and which support permanent structures, unless

naturally durable or preservative-treated wood is used. The pedestal shall project at least 6 inches above exposed

earth and at least 1 inch above floors.

12.Roof and ceiling framing (2015 IBC 2308.7).

12.1.Roof rafters and ceiling joists shall be supported laterally to prevent rotation and lateral displacement in accordance

with 2015 IBC 2308.7.8.

12.2.Rafters and joists over three feet long shall be supported using hanger hardware if not supported by bearing.

PREFABRICATED METAL PLATE WOOD TRUSSES

1. Prefabricated metal plate wood trusses shall be designed in accordance with 2015 IBC 2303.4 and shall conform to the

structural specifications and design criteria.

2. The truss designer shall provide a truss package that includes the following items:

2.1. Design drawings of each individual truss (2015 IBC 2303.4.3).

2.2. Truss placement diagram for the project (2015 IBC 2303.4.2).

2.3. Truss member permanent bracing specification (2015 IBC 2303.4.1.2).

3. Transfer of loads and anchorage of each truss to the supporting structure shall be approved by the registered design

professional in responsible charge (2015 IBC 2303.4.4).

4. Truss members and components shall not be cut, notched, drilled, spliced of otherwise altered in any way without written

concurrence and approval of the registered design professional in responsible charge. Alterations resulting in the addition

of loads to any member (e.g. HVAC equipment) shall not be permitted without verification that the truss is capable of

supporting such additional loading (2015 IBC 2303.4.5).

STEEL

1. Structural steel work shall conform to 2015 IBC 2205, AISC 341-10, AISC 358-10, and AISC 360-10.

2. Structural shapes

2.1. W: fy = 50 ksi (ASTM A992)

2.2. M,S,C,MC, and L: fy = 36 ksi (ASTM A36)

2.3. HP: fy = 50 ksi (ASTM A572 Gr. 50)

2.4. HSS Rectangular: fy = 46 ksi (ASTM A500 Gr.B)

2.5. HSS Round: fy = 42 ksi (ASTM A500 Gr.B)

2.6. Pipe: fy = 35 ksi (ASTM A53 Gr.B)2.7. All structural steel shall be properly primed and painted.

3. Plates and bars: fy = 36 ksi (ASTM A36)

4. Structural fasteners

4.1. High-strength bolts: fu = 105-150 ksi (ASTM A325, A490)

4.2. Common bolts: fu = 60 ksi (ASTM A307 Gr. A)

4.2.1. Nuts (ASTM A563)

4.2.2. Washers (ASTM F436)

4.2.3. Steel to steel bolted connections shall be made with high strength-bolts, unless noted otherwise. Bolts shall

carry the identifying mark of three radial lines. All other bolted connections shall be made with bolts and nuts

conforming to ASTM A307 unless note otherwise. Bolted connections shall be tightened and shall have washers as

required by AISC unless noted otherwise. Enlarging holes shall be accomplished by means of reaming. Do not use a

torch on any bolt holes.

4.3. Shear studs: fu = 65 ksi (ASTM A108)

4.4. Threaded rods: fy = 36 ksi (ASTM A36)

4.5. Anchor rods: fy = 36 ksi (ASTM F1554 Gr. 36)

5. Steel deck fy = 36 ksi (ASTM A611)

6. Welding fu = 70 ksi.

6.1. Welding work shall comply with the American Welding Society (AWS) “Structural Welding Code,” excluding items

conflicting with AISC requirements.

STRUCTURAL OBSERVATIONS

1. Where required by the Provisions of Section 1704.6.1 or 1704.6.2, the owner shall employ a registered design professional

to perform structural observations as defined in 2015 IBC 1705. Prior to the commencement of observations, the structural

observer shall submit to the building official a written statement identifying the frequency and extent of the structural

observations. At the conclusion of the work, the structural observer shall submit to the building official a written statement

that the site visits have been made and identify any reported deficiencies which have not been resolved (2015 IBC 1704.6).

DESIGN CRITERIA Detailed Drafting Lamphier Residence (Eden) 271216

1. Building code: Utah Code, Title 15A

1.1 Model building code: 2015 IRC

1.2 Use and occupancy classification: R (Residential - 1-unit dwelling)

1.3 Risk Category: II (Not occupancy categories I, III, IV)

2. Dead loads

2.1 Roof = 15 psf (10 psf top chord, 5 psf bottom chord)

2.2 Floor = 0 psf

2.3 Walls = 10 psf (interior walls), 12 psf (exterior walls)

3. Live loads

-- Roofs (ordinary construction) = 20 psf (or 300 lb point load)

-- Residential (1-2 unit dwelling) = 40 psf

-- Stairs and exits (residential 1-2 unit dwelling) = 40 psf (or 300 lb point load)

4. Snow load

4.1 Ground snow load, Pg = 52 psf (elevation 4960 ft)

4.2 Exposure factor, Ce = 1

4.3 Thermal factor, Ct = 1

4.4 Snow importance factor, Is = 1

4.5 Flat roof snow load, Pf = 35 psf

5. Earthquake design data

5.1 Mapped acceleration parameters

5.1.1 Latitude, Longitude: 41.302, -111.817

5.1.2 MCE short period Ss = 0.91 SDS = 0.69

5.1.3 MCE 1.0 sec. period S1 = 0.31 SD1 = 0.37

5.2 Seismic design category: D1

5.3 Seismic importance factor, Ie = 1

5.4 Basic structural system: Bearing wall systems

5.5 Seismic force-resisting system: Light-frame wood walls (wood sheathing)

5.5.1 Response modification factor R = 6.5

5.5.2 System overstrength factor Omega = 3

5.5.3 Deflection amplification factor Cd = 4

5.5 Equivalent Lateral Force Procedure

5.5.1 Seismic response coefficient Cs = 0.11

5.5.2 Seismic base shear (LRFD) V = 13372 lb

6. Wind design data

6.1 Exposure category: C

6.2 Ultimate design wind speed, Vult = 115 mph

6.3 Components and cladding pressure = 34 psf (end), 29 psf (interior)

6.4 Internal pressure coeff., Gcpi = 0.18

7. Geotechnical design basis:

- Presumptive values, 2015 IBC Table 1806.2

7.2 Site class = D

7.3 Soil notes: None

7.4 Lateral earth pressure

7.4.1 Active = 30 psf

7.4.2 At-rest = 60 psf

7.5 Allowable foundation parameters

7.5.1 Allowable soil bearing, Qa = 1500 psf

7.5.2 Allowable lateral bearing = 150 psf

7.5.3 Coefficient of friction = 0.25

7.6 Minimum frost cover = 36 in.

DEFERRED SUBMITTALS

1. The following items are to submitted subsequent to the time of application (deferred submittals):

-- Prefabricated metal plate wood trusses - roof (truss manufacturer)

2. Deferred submittals shall have the prior approval of the building official (2015 IBC 107.3.4.1).

3. Deferred submittal documents shall be submitted to the registered design professional in responsible charge who

shall review and forward them to the building official with a notation indicating that the documents have been

reviewed and found to be in general conformance to the design of the building (2015 IBC 107.3.4.1).

4. Deferred submittal items shall not be installed until the design and submittal documents have been approved by

the building official (2015 IBC 107.3.4.1).

SN1

GE

NE

RA

L S

TR

UC

TU

RA

L N

OT

ES

801.224.0050801.229.9020

[email protected]

1429 South State St.Orem, Utah 84097

PhoneFax

ORIGINAL PROJECT #

DRAWN BY:

CHECKED BY:

SCALE:

DATE:

THESE STRUCTURAL DRAWINGS ARE

BASED ON ARCHITECTURAL

DRAWINGS. SEE CURRENT ISSUE OR

REVISION DATE.

DIMENSIONS AND ELEVATIONS ARE

SUPPLIED BY THE ARCHITECT. THEY

MAY BE PROVIDED ON THE

STRUCTURAL PLANS AND DETAILS

FOR THE CONVENIENCE OF THE

CONTRACTOR. VERIFY DIMENSIONS

AND ELEVATIONS WITH

ARCHITECTURAL DRAWINGS.

ISSUES / REVISIONS

--

-

--

-

--

--

NTS

7 DEC 2016

271216

MCW

PRT

-

-

-

-

-

--

-01/04/2017

9-0

X8

-0 -

OV

ER

HE

AD

16-0X8-0 - OVERHEAD

LAYER

FOUNDATION SCHEDULE

REINFORCEMENT

HORIZONTALVERTICALWIDTHHEIGHTMARK

CENTERFW3 (3) #4#4 @ 24"8"3'

1. DOWEL VERTICAL BARS INTO FOOTING.

2. PLACE TOP AND BOTTOM BARS WITHIN 4" OF TOP AND BOTTOM OF WALL.

3. PLACE REINFORCEMENT IN CENTER OF WALL OR NEAR EACH FACE, AS NOTED.

REINFORCEMENT

LENGTHWISETRANSVERSETHICK.LENGTHWIDTHMARK

FOOTING SCHEDULE

FT20 20 " CONT. 10 " - (2) #4

FT22 22 " CONT. 10 " - (2) #4

SF24 24 " 24 " 10 " (3) #4 (3) #4

SF30 30 " 30 " 10 " (3) #4 (3) #4

UNLESS NOTED OTHERWISE.

AND SPOT FOOTINGS SHALL BE CENTERED UNDER COLUMNS

1. CONTINUOUS FOOTINGS SHALL BE CENTERED UNDER WALLS

BL

OC

K O

UT

BL

OC

K O

UT

FW3 FT20

FW

3F

T20

BLOCK OUT

S TYP.

V TYP.

FW

3F

T20

FW3 FT20

FW

3F

T20

FW3 FT20

FW

3F

T20

FW3 FT20

FW3FT20

FW

3F

T20

FW3FT20

FW

3F

T20

FW

3F

T20

FW

3F

T20

FW

3F

T20

FW3 FT20

FW

3F

T20

FW3 FT20

FW3FT20

FW

3F

T20

FW3 FT20

FW

3F

T22

FW3 FT22

BLOCK OUT

SF24

SF24

SF30

CZ TYP.

SF30SF24

S0.0

FO

OT

ING

AN

D F

OU

ND

AT

ION

PLA

N

SCALE: 1/4" = 1'-0"

1/4" = 1'-0"

801.224.0050801.229.9020

[email protected]

1429 South State St.Orem, Utah 84097

PhoneFax

ORIGINAL PROJECT #

DRAWN BY:

CHECKED BY:

SCALE:

DATE:

THESE STRUCTURAL DRAWINGS ARE

BASED ON ARCHITECTURAL

DRAWINGS. SEE CURRENT ISSUE OR

REVISION DATE.

DIMENSIONS AND ELEVATIONS ARE

SUPPLIED BY THE ARCHITECT. THEY

MAY BE PROVIDED ON THE

STRUCTURAL PLANS AND DETAILS

FOR THE CONVENIENCE OF THE

CONTRACTOR. VERIFY DIMENSIONS

AND ELEVATIONS WITH

ARCHITECTURAL DRAWINGS.

ISSUES / REVISIONS

--

-

--

-

--

--

7 DEC 2016

271216

MCW

PRT

-

-

-

-

-

--

-

01/04/2017

9-0

X8

-0 -

OV

ER

HE

AD

16-0X8-0 - OVERHEAD

SILL PLATESOLE PLATE

ANCHORAGE

SHEATHING

PANEL

NAILING

EDGEPANEL EDGE

ABUTTINGMARK

SHEAR WALL SCHEDULE

FRAMING

SW1 7/16" 8d @ 6" 2" NOMINAL 10d @ 12" 1/2" A.B. @ 32"

SW3 7/16" 8d @ 3" 3" NOMINAL 10d @ 12" 1/2" A.B. @ 32"

1. SHEATHING SHALL CONSIST OF WOOD STRUCTURAL PANELS (SEE GSN).

2. SHEATHING NAILS SHALL BE COMMON OR GALVANIZED BOX NAILS. - FIELD NAIL

SPACING SHALL BE 12" FOR STUDS SPACED 16" O.C. OR LESS AND 6" O.C. FOR STUDS

SPACED AT 24" O.C.

3. FOR SW1 ONLY, EDGE NAILS MAY BE SUBSTITUTED WITH 16 GAGE STAPLES SPACED

AT 3" O.C. AND FIELD NAILS MAY BE SUBSTITUTED WITH 16 GAGE STAPLES AT

12" O.C.

4. ANCHORAGE NAILS SHALL BE COMMON NAILS.

5. ANCHOR BOLTS SHALL HAVE A 3X3X0.229" WASHER AND 7" MIN EMBEDMENT. THE

WASHER SHALL EXTEND TO WITHIN 1/2" FROM THE SHEATHING.

6. FOR SW3, SW4, SW7, AND SW8, (2) 2" NOMINAL FRAMING STITCH-NAILED

TOGETHER WITH (2) 10d NAILS @ 6" MAY BE USED AT ABUTTING PANEL EDGES IN

PLACE OF 3" NOMINAL FRAMING.

POSTANCHORFASTENERSMARK HOLD-DOWN

HOLD-DOWN SCHEDULE

(2) 2X POSTA LSTHD8 (20) 10d STRAP 8" EMBED.

(2) 2X POSTC STHD14 (30) 10d STRAP 14" EMBED.

RIM JOIST LOCATIONS.

1. SIMPSON STRONG-TIE OR EQUIVALENT. STHD STRAPS USE "RJ" TYPE AT

POST.

2. NAILS SHALL BE COMMON NAILS. SHEAR WALL EDGE NAILING SHALL BE TO

3. MISPLACED STHD HOLD-DOWNS MAY BE RETROFITTED USING HTT5 HOLD-DOWNS

WITH 5/8" ALL- THREAD BOLTS. EPOXY INTO FOUNDATION WALL WITH 5 INCHES

WITH TWO 1/2" DIA. WEDGE ANCHORS AS OPTION. FASTEN WITH 16-16d COMMON

EMBEDMENT. WHERE FRAMED WALL IS FLUSH WITH FOUNDATION WALL USE MST48

NAILS TO POST ABOVE.

NO HOLD-DOWNS REQUIRED

SW1

NO HOLD-DOWNS REQUIRED

SW1

CC

CJ

C

A

C

SW1

FH

AA

CJ AD TYP.

SW

1

A

A

Y

SW1

AA

EM

SW1

A A

EM

NO HOLD-DOWNS REQUIRED

SW1

FH

SW

1

AA

NO

HO

LD

-DO

WN

S R

EQ

UIR

ED

SW

1

NO HOLD-DOWNS REQUIRED

SW1

FH

NO

HO

LD

-DO

WN

S R

EQ

UIR

ED

SW

1

NO HOLD-DOWNS REQUIRED

SW3

FHN

O H

OLD

-DO

WN

S R

EQ

UIR

ED

SW

1

FH

NO HOLD-DOWNS REQUIRED

SW1

NO

HO

LD

-DO

WN

S R

EQ

UIR

ED

SW

1

SCALE: 1/4" = 1'-0"

S1.0

MA

IN F

LO

OR

FR

AM

ING

PLA

N

1/4" = 1'-0"

801.224.0050801.229.9020

[email protected]

1429 South State St.Orem, Utah 84097

PhoneFax

ORIGINAL PROJECT #

DRAWN BY:

CHECKED BY:

SCALE:

DATE:

THESE STRUCTURAL DRAWINGS ARE

BASED ON ARCHITECTURAL

DRAWINGS. SEE CURRENT ISSUE OR

REVISION DATE.

DIMENSIONS AND ELEVATIONS ARE

SUPPLIED BY THE ARCHITECT. THEY

MAY BE PROVIDED ON THE

STRUCTURAL PLANS AND DETAILS

FOR THE CONVENIENCE OF THE

CONTRACTOR. VERIFY DIMENSIONS

AND ELEVATIONS WITH

ARCHITECTURAL DRAWINGS.

ISSUES / REVISIONS

--

-

--

-

--

--

7 DEC 2016

271216

MCW

PRT

-

-

-

-

-

--

-

01/04/2017

9-0

X8

-0 -

OV

ER

HE

AD

16-0X8-0 - OVERHEAD

BEAM SCHEDULE

MARK TYPE

RB 01 (2)2X6

RB 02 (3)2X6

RB 03 (3)2X8

RB 04 (2)2X6

RB 05 (3)1.75X9.5 LVL

RB 06 (3)2X8

RB 07 5.125X12 GLB

RB 08 (2)2X8

RB 09 5.125X12 GLB

RB 10 5.125X18 GLB

RB 11 (3)2X8

RB 12 5.125X13.5 GLB

RB 13 (3)2X8

RB 14 (2)2X6

RB 15 (3)2X8

RB 16 (3)2X6

RB 17 (3)2X8

RB 18 (3)2X6

RB 19 (2)2X6

RB 20 (2)2X10

RB 21 (2)2X10

RB 22 (2)2X10

1. DIMENSIONAL LUMBER DF#2 U.N.O.

2.0E

2. LAMINATED VENEER LUMBER (LVL)

24F-1.8E3. GLUED-LAMINATED TIMBER (GLB)

4. STEEL W-SHAPES A992-50

BEAM

5. SUFFIXES (A, B, ETC.) DENOTE

ALTERNATIVES FOR THE SPECIFIED

SHEATHING SCHEDULE

TYPE THICKNESS

FLOOR 3/4" (48/24 SPAN RATING)

ROOF 7/16" (24/16 SPAN RATING)

SUPPORTS.1. SHEATHING PERPENDICULAR TO

TO SUPPORT.

2. FLOOR SHEATHING NAILED & GLUED

12" O.C. (FIELD)

3. 8d COMMON NAILS 6" O.C. (EDGES)

PANEL EDGE.

4. NAILING NO CLOSER THAN 3/8" FROM

WOOD TRUSS LOADS

GROUND SNOW LOAD, Pg = 52 PSF

FLAT ROOF SNOW LOAD = 35 PSF

TOP CHORD DEAD LOAD = 10 PSF

BOTTOM CHORD DEAD LOAD = 5 PSF

CHAP.7 (2015 IBC 1608.1)

1. DESIGN SNOW LOADS SHALL BE IN

ACCORDANCE WITH ASCE 7-10

POST SCHEDULE

MARK TYPE

P 02 (2)2X POST

P 03 (3)2X POST

P 04 (4)2X POST

P 05 4X4 POST

P 07 6X6 POST

T 02 (2)TRIM

T 03 (3)TRIM

1.8E

1. PARALLEL STRAND LUMBER (PSL)

2. STEEL PIPE (PIPE STD) A53

3. STEEL HOLLOW SECTION (HSS) A500

PLATES4. STEEL COLUMNS REQUIRE BEARING

MEMBER

5. CONTINUE POSTS TO FDN / STRUCT

P 02

(2) 2

X PO

ST

P 02

(2) 2

X PO

ST

LF

LF

RB 15

RB

13

RB 14 RB 01 RB 01 RB 01

RB 01

RB 12

RB

01

P 03

(3) 2

X PO

ST

GIRDER TRUSS

T 02

(2) T

RIM

RB

16

EM

P 07

6X6 PO

ST

P 07

6X6 PO

ST

P 07

6X6

POST

P 02

(2) 2

X PO

ST

RB

06

T 03(3) TR

IM

T 02

(2) TRIM

RB 10

GIRDER TRUSS

EM

RB 01 RB 01 RB 01

P 04

(4) 2

X PO

ST

RB

09

RB 07RB 07

RB

08

T 02

(2) TRIM

T 02

(2) TRIM

RB 05RB 04RB 03RB 01

P 03

(3) 2

X PO

ST

P 04(4) 2X PO

ST

GIRDER TRUSS

P 04

(4) 2

X PO

ST

LF

GIRDER TRUSS

GIR

DE

R T

RU

SS

RB

01

RB

02

RB

01

RB 19

GIRDER TRUSS

P 02(2) 2X PO

ST

P 02

(2) 2

X PO

ST

P 054X

4 POST

P 02

(2) 2

X PO

ST

P 02

(2) 2X POST

P 05

4X4 PO

ST

P 02

(2) 2

X PO

ST

GIR

DE

R T

RU

SS

GIR

DER

TRUSS

RB 20

RB

22

RB 21

P 02(2) 2X POST

BE

AR

ING

WA

LL

BEAR UPPER TRUSSES

ON THIS WALL

PROVIDE BLOCKING AND

A35 CLIPS @ 24" O.C.

WHERE WALL AND

LOWER ROOF INTERSECT

DESIGN LOWER

TRUSSES FOR

LINE LOAD 50 plf

GIR

DE

R T

RU

SS

GIR

DE

R T

RU

SS

RB

01

RB

01

RB

11

RB

01

RB

01

RB 18 RB 18 RB 18

RB 17

P 04

(4) 2X POST

GIR

DE

R T

RU

SS

F TYP.

AP TYP.

Q TYP.

IA TYP.

DESIGN TRUSS FOR

75 plf DRAG LOAD

GIR

DER

TRUSS

P 02(2) 2X POST

P 02

(2) 2

X PO

ST

SCALE: 1/4" = 1'-0"

S3.0

RO

OF

FR

AM

ING

PL

AN

1/4" = 1'-0"

801.224.0050801.229.9020

[email protected]

1429 South State St.Orem, Utah 84097

PhoneFax

ORIGINAL PROJECT #

DRAWN BY:

CHECKED BY:

SCALE:

DATE:

THESE STRUCTURAL DRAWINGS ARE

BASED ON ARCHITECTURAL

DRAWINGS. SEE CURRENT ISSUE OR

REVISION DATE.

DIMENSIONS AND ELEVATIONS ARE

SUPPLIED BY THE ARCHITECT. THEY

MAY BE PROVIDED ON THE

STRUCTURAL PLANS AND DETAILS

FOR THE CONVENIENCE OF THE

CONTRACTOR. VERIFY DIMENSIONS

AND ELEVATIONS WITH

ARCHITECTURAL DRAWINGS.

ISSUES / REVISIONS

--

-

--

-

--

--

7 DEC 2016

271216

MCW

PRT

-

-

-

-

-

--

-

01/04/2017

NO SCALE

OVER BUILD FRAMING

NOTE: SUPPORT EACH RIDGE/HIP BEAM AND EACH

RAFTER WITH VERTICAL 2X "KICKERS" EVERY 48"

O.C. SUPPORT KICKERS ON ROOF FRAMING BELOW.FASTEN TO LEDGER WITH SIMPSON A34 @ 24" O.C.

ROOF FRAMING -

F

SUPPORT OVER-BUILD ON FULL

WIDTH OR MULTIPLE 2X

LEDGER FASTEN TO LOWER

FRAMING WITH (4) 10dX3" NAILS

LOWER ROOF FRAMING

OR WOOD TRUSSESRIDGE OR HIP BEAM

OVER-BUILD

FRAMING OR

WOOD TRUSS

24" O.C. U.N.O.

DOUBLE TOP PLATE

NO SCALE

OPTION 1

OPTION 2

(150 PLF UNIT SHEAR)ROOF FRAMING - BLOCKING

Q

SIMPSON OR USP

EQUIVALENT H1 OR H2.5A

ANCHORS EVERY TRUSS/RAFTER

EACH BEARING END. USE (2) ANCHORS

WHERE UPLIFT EXCEEDS 455 LB. (SEE

TRUSS MANUFACTURER).

WOOD TRUSS OR RAFTER

SIMPSON OR USP

EQUIVALENT H1 OR H2.5A

ANCHORS EVERY TRUSS/RAFTER

EACH BEARING END. USE (2) ANCHORS

WHERE UPLIFT EXCEEDS 455 LB. (SEE

TRUSS MANUFACTURER).

WOOD TRUSS OR RAFTER

SHEATHING (SEE

NAILING SCHEDULE)

10dX3" @ 6" O.C.

DIAPHRAGM BOUNDARY NAILING

2X BLOCKING EVERY

THIRD BLOCK MAY BE

TURNED FLATWISE

FOR VENTILATION

DIAPHRAGM BOUNDARY NAILING

2X BLOCKING EVERY

THIRD BLOCK MAY BE

TURNED FLATWISE

FOR VENTILATION

NO SCALE

FOUNDATION WALL

CORNER DOWELS TYP. @

FOOTINGS & FOUNDATION

CORNER

INTERSECTION

REQUIRED LAP LENGTHCONCRETE

12 BAR DIA.

40 BAR DIA.

HORIZONTAL REINFORCING AS CALLED

OUT IN GENERAL STRUCTURAL NOTES

OR STRUCTURAL DRAWINGS

HOOK

TYPE

SPLICE

HO

OK

12"

24"

MASONRY

20 BAR DIA.

48 BAR DIA.

MIN.

SPLICE

CORNER & INTERSECTIONFOUNDATION WALL -

REINFORCINGS NO SCALE

SLAB ON GRADE

SEE FOOTING AND

FOUNDATION PLAN

SE

E S

TR

UC

TU

RA

L C

ALC

UL

AT

ION

MIN

. F

RO

ST

DE

PT

H

SE

E F

OO

TIN

G A

ND

FO

UN

DA

TIO

N P

LA

N

3"

CLR

.

3"

FOUNDATION WALL -

V

2X STUD WALL

ANCHOR BOLT (SEE SHEAR

WALL SCHEDULE FOR SPACING)

WITH 3X3X0.229" PL WASHER

CONCRETE SLAB

PROCTOR IN LIFTS

NOT TO EXCEED 9 IN.

SEE FOUNDATION SCHEDULE

ROUGHENED SURFACE WITH

1/4" MIN. IRREGULARITIES

DOWELS TO MATCH

VERTICAL WALL

REINFORCING

SEE FOOTING

SCHEDULE

CONCRETE FOOTING

SHEATHING - SEE SCHEDULE

NATURALLY DURABLE

OR PRESERVATIVE -

TREATED WOOD SILL PLATE

ADDITIONAL STRAPPING AND BLOCKING

AROUND OPENINGS ARE NOT REQUIRED.

SEE STRUCTURAL PLAN FOR SHEAR WALL EXTENT AND REQUIREMENTS

NO SCALE

PERFORATEDY

HOLD-DOWN (SEE

STRUCTURAL)SEE SHEAR WALL

SCHEDULE FOR

ANCHOR BOLTS

SIZE AND SPACING

HOLD-DOWN (SEE

STRUCTURAL)

WINDOW OPENING

(WHERE OCCURS)

DOOR OPENING

(WHERE OCCURS)

(2) 2X POST OR 4X

POST - PROVIDE EDGE

NAILING ALONG FULL

HEIGHT OF POST

SHEAR WALL -

NO SCALEADFOUNDATION STRAPHOLD-DOWN -

POST (SEE

HOLD-DOWN

SCHEDULE)

EMBEDDED FOUNDATION STRAP

(SEE HOLD-DOWN SCHEDULE)

RIM JOIST WHERE OCCURS

CL

EA

R S

PA

N

17

" M

AX

IMU

M

NA

ILE

D P

OR

TIO

N

30" MIN.

REBAR

LENGTH

ONE #4

REBAR IN

SHEAR

CONE (12"

MIN. REBAR

LENGTH)1/2" MIN.

FROM

CORNER

AP NO SCALE

TOP PLATE SPLICEDIAPHRAGM -

4'-0"

MINIMUM BETWEEN SPLICES

TOP PLATE TO LOWER PLATE:

12 - 16d NAILS (2 ROWS OF 6)

LOWER PLATE TO TOP OF STUDS:

2 - 16d NAILS AT EACH STUD

8'-0" MINIMUM TO NEXT LAP

4" TYP.

1"

TY

P.

NOTE: WHERE DOUBLE TOP PLATE IS

CUT DUE TO INTERSECTING BEAMS,

WALLS, ETC. PROVIDE (2) CS16 STRAPS

ACROSS CUT WITH 12" END LENGTHS

EXTENT OF HEADER

10

' -

MA

X H

EIG

HT

CJ NO SCALE

CONCRETE FOUNDATIONAPA PORTAL FRAME -

(2) ROWS 16d

SINKER NAILS

@ 3" O.C.

3/8" MIN. THICKNESS WOOD

STRUCTURAL PANEL SHEATHING

HOLD-DOWN

(SEE STRUCTURAL)

SHEATHING

FILLER IF

NEEDED

2' TO 18' (CLEAR SPAN)

(2) CS16 OR (2) MST27 STRAPS

OPPOSITE SHEATHING

IF PANEL SPLICE IS NEEDED IT SHALL

OCCUR WITHIN 24" OF MID-HEIGHT,

2X BLOCKING REQUIRED.

(2) 2X MIN.

MIN. 3"X3"X0.229"

PLATE WASHER(S)

(2) 1/2" ANCHOR BOLTS OR

(1) 5/8" ANCHOR BOLT WITH

7" MIN. EMBED.HOLD-DOWNS

(SEE STRUCTURAL)

ATTACH SHEATHING TO TOP PLATE

WITH 8d NAILS AT 4" O.C. STAGGERED

3" X 11-1/4" MIN. HEADER

(SEE STRUCTURAL)

2' -

MA

X P

ON

Y

WA

LL H

EIG

HT

12

' -

MA

X T

OT

AL W

ALL H

EIG

HT

FASTEN SHEATHING TO HEADER WITH

8d COMMON NAILS IN 3" GRID PATTERN

AS SHOWN AND 3" O.C. IN ALL FRAMING

(STUDS AND SILLS) TYP.

FULL-HEIGHT STUD

CZ NO SCALE

FOOTING CONNECTION

GRADE

PIER STEM TO SPOTFOOTING - CONCRETE

SE

E C

AL

CU

LA

TIO

NS

FO

R F

RO

ST

DE

PT

H

4"

MA

X.

12"

(U.N.O.)

#4 BARS @ 6"

O.C. VERTICAL

#4 BARS @ 6"

O.C. VERTICAL

16

" L

AP

SP

LIC

E

IF R

EQ

UIR

ED

3"

CO

VE

R

SEE FOOTING

SCHEDULE

12 BAR DIA.

SE

E F

OO

TIN

G

SC

HE

DU

LE

#3 TIES @ 8" O.C.

(3) #3 TIES WITHIN 5" OF TOP

MINIMUM BEND INSIDE

RADIUS = 6 BAR DIA.

SEE FOOTING SCHEDULE FOR

BAR SIZE AND QUANTITY

EM NO SCALE

DIAPHRAGM CONNECTIONSHEAR WALL - ROOF

SHEAR WALL

PRE-FABRICATED

TRUSS BLOCKING

OR

SHEAR WALL

DOUBLE TOP PLATE

SIMPSON LTP4

@ 16" O.C. OR

A35 @ 12" O.C.

2X FRAMING

NAILING - SAME AS

SHEAR WALL BELOW

NAIL BLOCKING TO

TRUSSES WITH 16d

NAILS @ 6" O.C.

SHEATHINGROOF SHEATHING10d @ 3" O.C.

SHEATHING

ROOF SHEATHING

DRAG TRUSS OR FRAMED WALL WITH

SHEATHING AND NAILING SAME AS

SHEAR WALL ALIGNED BELOW

DOUBLE TOP PLATE

10d @ 3" O.C.

SIMPSON A35 @ 12" O.C.

OR LTP4 @ 16" O.C.

SHEAR WALL (SEE

STRUCTURAL)

FH NO SCALE

AROUND OPENINGSFORCE TRANSFERSHEAR WALL -

SEE STRUCTURAL PLAN FOR SHEAR WALL EXTENT AND REQUIREMENTS

SEE SHEAR WALL SCHEDULE FOR

ANCHOR BOLTS SIZE AND SPACING

HOLD-DOWN IF

REQUIRED (SEE

STRUCTURAL)

WINDOW OPENING

(WHERE OCCURS)DOOR OPENING

(WHERE OCCURS)

CS16 (32" LONG) WITH SOLID

BLOCKING AT TOP OF OPENING

CS16 (32" LONG) WITH SOLID

BLOCKING AT BOTTOM OF

OPENING

CS16 (32" LONG) WITH

SOLID BLOCKING AT

TOP OF OPENING

(2) 2X POST OR 4X

POST - PROVIDE

EDGE NAILING

ALONG FULL

HEIGHT OF POST

IA NO SCALE

WALL HEADER FRAMING

HEADER

(SEE STRUCTURAL)

WOOD BEAM -

TWO PLIES:

10d COMMON (0.148X3")

NAILS @ 24" O.C.

THREE OR MORE PLIES:

FACE NAILING 10d

COMMON (0.148X3") NAILS

@ 6" O.C. STAGGERED

KING STUD MIN.

(1) PLY U.N.O.

TRIMMER(S)

(SEE STRUCTURAL)

BEAM OR GIRDER TRUSS

(SEE STRUCTURAL PLANS)

BEAM OR GIRDER TRUSS

(SEE STRUCTURAL PLANS)

DIAPHRAGM - CHORD /

LF NO SCALE

COLLECTOR STRAP

DOUBLE TOP PLATE

DOUBLE TOP PLATE

DOUBLE TOP PLATE

(2) SIMPSON CS16 STRAPS 24" LONG

(2) SIMPSON CS16 STRAPS 24" LONG

SLIDE STRAP BETWEEN

BEAM AND WALL

BEAM OR GIRDER TRUSS

(SEE STRUCTURAL PLANS)

(2) SIMPSON CS16 STRAPS (10) -10d

NAILS EACH END OF EACH CS16 (CUT

TO REQUIRED LENGTH) OR DSC OR

EQUIVALENT

ZA NO SCALE

ROOF SHEAR TRANSFERUPPER TO LOWER

BEAM (SEE

STRUCTURAL)

UPPER

ROOF

TRUSSES

TRUSS HANGER

PROVIDE BLOCKING

BETWEEN TRUSSES

10d @

3" O.C.

APPLY SW1 NAILING

AND ANCHORAGE

SHEAR WALL SHEATHING

UPPER WALL

ROOF SHEATHING

LOWER ROOF

SHEATHING

LOWER ROOF

TRUSSES

BEAM (SEE

STRUCTURAL)

UPPER

ROOF

TRUSSES

ROOF

SHEATHING

UPPER WALL

SECTION. APPLY SW1

NAILING TO WALL

(SEE SCHEDULE)

ROOF

SHEATHING

SIMPSON

LS50 @ 12"

LOWER

ROOF TRUSS

BLOCKING

BETWEEN STUDS

SD1

ST

RU

CT

UR

AL D

ET

AIL

S

801.224.0050801.229.9020

[email protected]

1429 South State St.Orem, Utah 84097

PhoneFax

ORIGINAL PROJECT #

DRAWN BY:

CHECKED BY:

SCALE:

DATE:

THESE STRUCTURAL DRAWINGS ARE

BASED ON ARCHITECTURAL

DRAWINGS. SEE CURRENT ISSUE OR

REVISION DATE.

DIMENSIONS AND ELEVATIONS ARE

SUPPLIED BY THE ARCHITECT. THEY

MAY BE PROVIDED ON THE

STRUCTURAL PLANS AND DETAILS

FOR THE CONVENIENCE OF THE

CONTRACTOR. VERIFY DIMENSIONS

AND ELEVATIONS WITH

ARCHITECTURAL DRAWINGS.

ISSUES / REVISIONS

--

-

--

-

--

--

NTS

7 DEC 2016

271216

MCW

PRT

-

-

-

-

-

--

-

01/04/2017