9
NOTE NUMBERS 9 NORTH GENERAL NOTES: NOTE: TO ORDER STANDARD CRITERIA PLANS GO TO WWW.PLANEXPRESS.NET. THE LOGIN AND PASSWORD ARE LLDEV. PLACE ORDER FOR TSC'S STANDARD CRITERIA PLANS - CURRENT PLANS WILL BE Q1 2020. TO ORDER DWG/CAD FILES SEND EMAIL TO [email protected]. INCLUDE PEI ACCOUNT # OR CREDIT CARD # WITH TYPE OF CREDIT CARD, NAME ON CARD, CREDIT CARD #, EXPIRATION DATE AND ZIP CODE OF BILLING ADDRESS. ANY PROBLEMS OR QUESTIONS, YOU MAY CONTACT CINDY PIND @ 901.869.2465. NORTH 1. ALL CONSTRUCTION AND DETAILS SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES AND ORDINANCES AS OF THE DATE OF THE DRAWINGS. ANY DEVIATIONS FROM BUILDING CODES REQUIRES NOTIFICATION AND APPROVAL FROM TSC PROJECT MANAGER. 2. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS OF THE SITE. DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT & OWNER PRIOR TO PROCEEDING WITH CONSTRUCTION. 3. REMOVE ALL CONSTRUCTION AND DEMOLITION DEBRIS FROM JOB SITE DAILY. MAKE JOB PREMISES CLEAN AT COMPLETION OF PROJECT. 4. FIRE EXTINGUISHERS SHALL BE INSTALLED IN ACCORDANCE WITH THE LOCAL FIRE DEPARTMENT PRIOR TO COMPLETION OF CONSTRUCTION. 5. ALL DIMENSIONS ARE FACE OF DRYWALL AT NEW WALLS AND TO FINISHED FACE AT MASONRY WALLS UNLESS NOTED OTHERWISE. 6. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS. 7. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. IF DISCREPANCIES ARE FOUND, THE ARCHITECT AND OWNER SHALL BE NOTIFIED IMMEDIATELY. 8. THRESHOLDS SHALL NOT EXCEED 1/2 INCH IN HEIGHT. 9. DRYWALL TO BE HELD UP 1/2" ABOVE CONCRETE FLOOR. 10. SPECIFIC MANUFACTURERS AND PRODUCTS ARE NAMED ON THE DRAWINGS TO INDICATE THE MINIMUM ACCEPTABLE LEVEL OF QUALITY. EQUAL OR BETTER PRODUCTS WILL BE CONSIDERED. SUBSTITUTES MUST BE APPROVED BY TSC PM. 11. CONCEAL ALL PIPING IN WALLS. WHERE PIPING IS TOO LARGE WALLS ARE TO BE FURRED OUT A MINIMUM TO CONCEAL PIPING. 12. PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES. 13. ALL COUNTERTOPS TO BE 2'-0" IN DEPTH UNLESS OTHERWISE NOTED. 14. PROVIDE SOLID BLOCKING FOR WALL HUNG CABINETS, PLUMBING FIXTURES, ACCESSORIES AND MILLWORK. 15. ALL MATERIALS USED BY ALL TRADES SHALL BE LISTED AND LABELED BY AN APPROVED AGENCY AND INSTALLED PER THE MANUFACTURES INSTRUCTIONS. 16. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ANY DUCT SMOKE DETECTOR FOR NEW WORK ONLY. COORDINATE WITH THE ASSIGNED ALARM COMPANY. 17. THE GENERAL CONTRACTOR SHALL SUBMIT A REPORT, ON A WEEKLY BASIS INDICATING THE PERCENT COMPLETE FOR EACH LINE ITEM ON THE SCHEDULE USING THE TSC WEEKLY PROGRESS REPORT ALONG WITH PHOTOS PER PHOTO LOG ON THE BLANK REPORTS PROVIDED BY TSC. 18. 'J' MOLD TO BE USED AT ALL INTERSECTIONS OF GYPSUM BOARD AND ANY OTHER NON-GYPSUM MATERIAL. 19. CORNER GUARDS TO BE USED AT ALL INTERIOR 'OUTSIDE' CORNER CONDITIONS. 20. FINISHED SPACE SHALL BE PROVIDED IN A MANNER THAT PREVENTS RODENT INTRUSION. SEAL PENETRATIONS THROUGH EXTERIOR WALL SURFACES WITH AN AEROSOL, MOISTURE-CURING POLYURETHANE FOAM SIMILAR TO "PUR BLACK" BY TODOL PRODUCTS, INC. (508.651.3818) OR APPROVED EQUAL. CONTRACTOR RESPONSIBILITIES CONTRACTOR SHALL VERIFY EXISTING CONDITIONS ON SITE. DISCREPANCIES BETWEEN DRAWINGS AND EXISTING CONDITIONS AS WELL AS DISCREPANCIES BETWEEN LANDLORD WORK AND TSC WORK SHALL BE BROUGHT TO THE ATTENTION OF TSC AND ARCHITECT IN WRITING PRIOR TO BID SUBMISSION. ARCHITECTURAL A1.0 ARCHITECTURAL FLOOR PLAN 2 A2.0 2 INTERIOR ELEVATION INDICATOR ROOM LARGE SCALE ROOM NUMBER REVISION DETAIL ROOM NAME 210 BENCH MARK DOOR NUMBER SECTION CUT DRAWING NO. 9 16 DETAIL SCALE: 3/4 " = 1'-0" GRAPHIC SYMBOLS VICINITY MAP TRACTOR SUPPLY COMPANY SHALL NOT BE RESPONSIBLE FOR THE PAYMENT OF ANY WORK PERFORMED OR MATERIAL SUPPLIED BY THE CONTRACTOR OR ANY OF ITS SUB-CONTRACTORS, SUB-SUBCONTRACTORS AND ANYONE CLAIMING BY THROUGH OR UNDER ANY OF THEM WHICH IS NOT IDENTIFIED IN WRITING AND SIGNED BY ONE OF THE FOLLOWING TRACTOR SUPPLY COMPANY PERSONNEL: VICE PRESIDENT REAL ESTATE, VICE PRESIDENT OF CONSTRUCTION, OR A CONSTRUCTION PROJECT MANAGER. NO ACTION, CONDUCT, OMISSION, PRIOR FAILURE, OR COURSE OF DEALING BY TRACTOR SUPPLY COMPANY SHALL ACT TO WAIVE, MODIFY, CHANGE OR ALTER THE REQUIREMENT THAT ALL WORK, WHETHER BY CONTRACT, CHANGE ORDER OR CHANGE DIRECTIVE, MUST BE IN WRITING AND SIGNED BY THE PERSONNEL IDENTIFIED IN THIS PROVISION. ANY WORK PERFORMED OR MATERIAL PROVIDED BY THE CONTRACTOR, ANY OF ITS SUB-CONTRACTORS, SUB-SUBCONTRACTORS CONTRARY TO THIS PROVISION SHALL BE AT ITS OWN RISK AND OWN EXPENSE AND TRACTOR SUPPLY COMPANY SHALL NOT BE OBLIGATED TO REIMBURSE OR PAY THE CONTRACTOR OR ANY OF ITS SUB-CONTRACTORS, SUB-SUBCONTRACTORS FOR SAME. CHANGE ORDER POLICY DRAWING INDEX ISSUED FOR CONSTRUCTION 11.23.2020 REVISION DATE: XX.XX.XXXX REVISION DATE: XX.XX.XXXX REVISION DATE: XX.XX.XXXX REVISION DATE: XX.XX.XXXX REVISION DATE: XX.XX.XXXX REVISION DATE: XX.XX.XXXX TENANT PLUMBING ENGINEER SCHELTON ENGINEERING ELECTRICAL ENGINEER PARSONS ENGINEERING PROJECT MANAGER RODNEY RUNIONS 615.386.9396 [email protected] 4751 TROUSDALE DRIVE SUITE 202 NASHVILLE, TN 37203 1163 W. MAIN STREET FRANKLIN, TN 37064 PROJECT MANAGER GARY W. SCHELTON, P.E., LEED AP 615.730.9111 [email protected] PROJECT ARCHITECT GLEN P. OXFORD, AIA TRACTOR SUPPLY COMPANY 5401 VIRGINIA WAY BRENTWOOD, TENNESSEE POINT OF CONTACT ELIZABETH MORRISETTE 615.256.3455 X 14 [email protected] PROJECT MANAGER JR OSBORN 615.948.9088 ARCHITECT 2934 Sidco Drive Suite 120 Nashville, TN 37204 OXFORD ARCHITECTURE PROJECT LOCATION NORTH COLLIERVILLE, TENNESSEE 240 US HIGHWAY 72 WEST STREET THE STUFF YOU NEED OUT HERE www.myTSCstore.com 2000.064 - TSC - COLLIERVILLE, TN FUSION ABBREVIATIONS ABV: ABOVE ACT: ACCOUSTICAL CEILING TILE ADA: AMERICANS WITH DISABILITIES ACT ADJ: ADJACENT AFF: ABOVE FINISH FLOOR ALUM: ALUMINUM APPROX: APPROXIMATE BLDG: BUILDING BTM: BOTTOM CL: CENTER LINE CMU: CONCRETE MASONRY UNIT CONC: CONCRETE DIA: DIAMETER DIM: DIMENSION DWG: DRAWING EIFS: EXTERIOR INSULATION & FINISH SYSTEM INSUL: INSULATION MECH: MECHANICAL MFG: MANUFACTURER FFE: FINISH FLOOR ELEVATION FIN: FINISH FLR: FLOOR FRP: FIBERGLASS REINFORCED PANEL FT: FEET GC: GENERAL CONTRACTOR GD: GRADE GYP BD: GYPSUM BOARD HC: ACCESSIBLE HGT: HEIGHT HM: HOLLOW METAL HVAC: HEATING, VENTILATING & AIR CONDITIONING HWY: HIGHWAY MTD: MOUNTED OC: ON CENTER PL: PROPERTY LINE PLYWD: PLYWOOD PP: POWER POLE PR: PAIR PSI: POUNDS PER SQUARE INCH PT: PAINT PTD: PAINTED PVMT: PAVEMENT RCP: REFLECTED CEILING PLAN REQ: REQUIRED SPECS: SPECIFICATIONS SQ: SQUARE STD: STANDARD STRUCT: STRUCTURAL TRANS: TRANSFORMER W/: WITH W/O: WITHOUT WD: WOOD WH: WATER HEATER WWF: WELDED WIRE FABRIC COLLIERVILLE, TENNESSEE REMODELING SOON 38017 COVER SHEET D1.0 DEMOLITION PLAN 6 4 A4.0 A5.02 2 A0.0 SCOPE OF WORK A1.1 ENLARGED PLAN, ELEVATIONS & DETAILS SCOPE OF WORK & ALTERNATES SEE A0.0 A0.1 COLOR & FINISH SCHEDULES REMODEL BUILDING AREA LIMITS SALES FLOOR EXISTING 18,630 SQ. FT. / 30 22,712 SQ. FT. TOTAL BUILDING AREA EXISTING OCCUPANCY LOAD = 621.0 OR 621 MECHANICAL AND PLUMBING FLOOR PLAN MP1.0 MECHANICAL & PLUMBING STOCKROOM EXISTING 2,502 SQ. FT. / 300 = 8.3 OR 9 TOTAL OCCUPANT LOAD EXISTING = 653 CORE AREA EXISTING 1,300 SQ. FT. / 100 = 13.0 OR 13 VESTIBULE EXISTING 280 SQ. FT. / 30 =9.3 OR 10 PROJECT DATA 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL PLUMBING CODE 2018 INTERNATIONAL MECHANICAL CODE 2017 NATIONAL ELECTRIC CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL FUEL GAS CODE IIB FIRE SUPRESSION CONSTRUCTION TYPE OCCUPANCY CLASSIFICATION SPRINKLERED (EXISTING TO REMAIN) MERCANTILE PROJECT SUMMARY ALARM SYSTEM ALARMED (EXISTING TO REMAIN) NUMBER OF STORIES 1 (EXISTING TO REMAIN) WALL TYPES GENERAL LIGHTING PLAN E1.0 ELECTRICAL ELECTRICAL NOTES AND DETAILS E2.0 THIS PROJECT IS BASED ON THE REQUIREMENTS OF THE 2018 TENNESSEE BUILDING CODES WHICH IS BASED UPON THE FOLLOWING: EXISTING WALL TO REMAIN TRACTOR SUPPLY COMPANY IS REMODELING THIS STORE TO INCLUDE NEW ELECTRICAL UPDATES, TOUCHLESS FIXTURES, AND GENERAL UPKEEP TO THE BUILDING AS A PART OF THEIR NEW FUSION INITIATIVE. 5/8" TYPE "X" GYP. BD. BOTH SIDES OF 3 5/8" METAL STUDS EXTEND 4" ABOVE CEILING TILE

COLLIERVILLE, TENNESSEE REVISION DATE: …

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COLLIERVILLE, TENNESSEE REVISION DATE: …

NOTE NUMBERS 9

NORTH

GENERAL NOTES:

NOTE: TO ORDER STANDARD CRITERIA PLANS GO TO WWW.PLANEXPRESS.NET. THE LOGIN ANDPASSWORD ARE LLDEV. PLACE ORDER FOR TSC'S STANDARD CRITERIA PLANS - CURRENT PLANSWILL BE Q1 2020. TO ORDER DWG/CAD FILES SEND EMAIL [email protected]. INCLUDE PEI ACCOUNT # OR CREDIT CARD # WITH TYPEOF CREDIT CARD, NAME ON CARD, CREDIT CARD #, EXPIRATION DATE AND ZIP CODE OF BILLINGADDRESS. ANY PROBLEMS OR QUESTIONS, YOU MAY CONTACT CINDY PIND @ 901.869.2465.

NORTH1. ALL CONSTRUCTION AND DETAILS SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES AND

ORDINANCES AS OF THE DATE OF THE DRAWINGS. ANY DEVIATIONS FROM BUILDING CODES REQUIRES NOTIFICATION ANDAPPROVAL FROM TSC PROJECT MANAGER.

2. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS OF THE SITE. DISCREPANCIES SHALL BE REPORTED TO THEARCHITECT & OWNER PRIOR TO PROCEEDING WITH CONSTRUCTION.

3. REMOVE ALL CONSTRUCTION AND DEMOLITION DEBRIS FROM JOB SITE DAILY. MAKE JOB PREMISES CLEAN AT COMPLETIONOF PROJECT.

4. FIRE EXTINGUISHERS SHALL BE INSTALLED IN ACCORDANCE WITH THE LOCAL FIRE DEPARTMENT PRIOR TO COMPLETION OFCONSTRUCTION.

5. ALL DIMENSIONS ARE FACE OF DRYWALL AT NEW WALLS AND TO FINISHED FACE AT MASONRY WALLS UNLESS NOTEDOTHERWISE.

6. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS.7. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. IF DISCREPANCIES ARE FOUND, THE ARCHITECT AND OWNER SHALL BE

NOTIFIED IMMEDIATELY.8. THRESHOLDS SHALL NOT EXCEED 1/2 INCH IN HEIGHT.9. DRYWALL TO BE HELD UP 1/2" ABOVE CONCRETE FLOOR.10. SPECIFIC MANUFACTURERS AND PRODUCTS ARE NAMED ON THE DRAWINGS TO INDICATE THE MINIMUM ACCEPTABLE LEVEL

OF QUALITY. EQUAL OR BETTER PRODUCTS WILL BE CONSIDERED. SUBSTITUTES MUST BE APPROVED BY TSC PM.11. CONCEAL ALL PIPING IN WALLS. WHERE PIPING IS TOO LARGE WALLS ARE TO BE FURRED OUT A MINIMUM TO CONCEAL

PIPING.12. PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES.13. ALL COUNTERTOPS TO BE 2'-0" IN DEPTH UNLESS OTHERWISE NOTED.14. PROVIDE SOLID BLOCKING FOR WALL HUNG CABINETS, PLUMBING FIXTURES, ACCESSORIES AND MILLWORK.15. ALL MATERIALS USED BY ALL TRADES SHALL BE LISTED AND LABELED BY AN APPROVED AGENCY AND INSTALLED PER THE

MANUFACTURES INSTRUCTIONS.16. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ANY DUCT SMOKE DETECTOR FOR NEW WORK ONLY.

COORDINATE WITH THE ASSIGNED ALARM COMPANY.17. THE GENERAL CONTRACTOR SHALL SUBMIT A REPORT, ON A WEEKLY BASIS INDICATING THE PERCENT COMPLETE FOR EACH

LINE ITEM ON THE SCHEDULE USING THE TSC WEEKLY PROGRESS REPORT ALONG WITH PHOTOS PER PHOTO LOG ON THEBLANK REPORTS PROVIDED BY TSC.

18. 'J' MOLD TO BE USED AT ALL INTERSECTIONS OF GYPSUM BOARD AND ANY OTHER NON-GYPSUM MATERIAL.19. CORNER GUARDS TO BE USED AT ALL INTERIOR 'OUTSIDE' CORNER CONDITIONS.20. FINISHED SPACE SHALL BE PROVIDED IN A MANNER THAT PREVENTS RODENT INTRUSION. SEAL PENETRATIONS THROUGH

EXTERIOR WALL SURFACES WITH AN AEROSOL, MOISTURE-CURING POLYURETHANE FOAM SIMILAR TO "PUR BLACK" BYTODOL PRODUCTS, INC. (508.651.3818) OR APPROVED EQUAL.

CONTRACTOR RESPONSIBILITIESCONTRACTOR SHALL VERIFY EXISTING CONDITIONS ON SITE. DISCREPANCIES BETWEEN DRAWINGS AND EXISTING CONDITIONS ASWELL AS DISCREPANCIES BETWEEN LANDLORD WORK AND TSC WORK SHALL BE BROUGHT TO THE ATTENTION OF TSC ANDARCHITECT IN WRITING PRIOR TO BID SUBMISSION.

ARCHITECTURAL

A1.0 ARCHITECTURAL FLOOR PLAN

2A2.0

2

INTERIOR ELEVATION

INDICATOR

ROOM

LARGE SCALE

ROOM NUMBER

REVISION

DETAIL

ROOM NAME

210

BENCH MARK

DOOR NUMBER

SECTION CUT

DRAWING NO.

9

16 DETAILSCALE: 3/4 " = 1'-0"

GRAPHIC SYMBOLS VICINITY MAP

TRACTOR SUPPLY COMPANY SHALL NOT BE RESPONSIBLE FOR THE PAYMENT OF ANY WORK PERFORMED OR MATERIAL SUPPLIED BYTHE CONTRACTOR OR ANY OF ITS SUB-CONTRACTORS, SUB-SUBCONTRACTORS AND ANYONE CLAIMING BY THROUGH OR UNDER ANYOF THEM WHICH IS NOT IDENTIFIED IN WRITING AND SIGNED BY ONE OF THE FOLLOWING TRACTOR SUPPLY COMPANY PERSONNEL:VICE PRESIDENT REAL ESTATE, VICE PRESIDENT OF CONSTRUCTION, OR A CONSTRUCTION PROJECT MANAGER. NO ACTION, CONDUCT,OMISSION, PRIOR FAILURE, OR COURSE OF DEALING BY TRACTOR SUPPLY COMPANY SHALL ACT TO WAIVE, MODIFY, CHANGE OR ALTERTHE REQUIREMENT THAT ALL WORK, WHETHER BY CONTRACT, CHANGE ORDER OR CHANGE DIRECTIVE, MUST BE IN WRITING ANDSIGNED BY THE PERSONNEL IDENTIFIED IN THIS PROVISION. ANY WORK PERFORMED OR MATERIAL PROVIDED BY THE CONTRACTOR,ANY OF ITS SUB-CONTRACTORS, SUB-SUBCONTRACTORS CONTRARY TO THIS PROVISION SHALL BE AT ITS OWN RISK AND OWNEXPENSE AND TRACTOR SUPPLY COMPANY SHALL NOT BE OBLIGATED TO REIMBURSE OR PAY THE CONTRACTOR OR ANY OF ITSSUB-CONTRACTORS, SUB-SUBCONTRACTORS FOR SAME.

CHANGE ORDER POLICY

DRAWING INDEXISSUED FOR CONSTRUCTION

11.23.2020

REVI

SION

DAT

E: X

X.XX

.XXX

X

REVI

SION

DAT

E: X

X.XX

.XXX

X

REVI

SION

DAT

E: X

X.XX

.XXX

X

REVI

SION

DAT

E: X

X.XX

.XXX

X

REVI

SION

DAT

E: X

X.XX

.XXX

X

REVI

SION

DAT

E: X

X.XX

.XXX

X

TENANT

PLUMBING ENGINEER SCHELTON ENGINEERING

ELECTRICAL ENGINEERPARSONS ENGINEERING

PROJECT MANAGER

RODNEY [email protected]

4751 TROUSDALE DRIVESUITE 202NASHVILLE, TN 37203

1163 W. MAIN STREETFRANKLIN, TN 37064

PROJECT MANAGER

GARY W. SCHELTON, P.E., LEED [email protected]

PROJECT ARCHITECTGLEN P. OXFORD, AIA

TRACTOR SUPPLY COMPANY5401 VIRGINIA WAYBRENTWOOD, TENNESSEE

POINT OF CONTACTELIZABETH MORRISETTE615.256.3455 X [email protected]

PROJECT MANAGERJR OSBORN615.948.9088

ARCHITECT

2934 Sidco DriveSuite 120Nashville, TN 37204

OXFORDARCHITECTURE

PROJECT

LOCATION

NORTH

COLLIERVILLE, TENNESSEE240 US HIGHWAY 72 WEST STREET

THE STUFF YOU NEED OUT HEREwww.myTSCstore.com

2000

.064

- T

SC -

CO

LLIE

RVIL

LE, T

N F

USI

ON

ABBREVIATIONSABV: ABOVEACT: ACCOUSTICAL CEILING TILEADA: AMERICANS WITH

DISABILITIES ACTADJ: ADJACENTAFF: ABOVE FINISH FLOORALUM: ALUMINUMAPPROX: APPROXIMATEBLDG: BUILDINGBTM: BOTTOMCL: CENTER LINECMU: CONCRETE MASONRY UNITCONC: CONCRETEDIA: DIAMETERDIM: DIMENSIONDWG: DRAWINGEIFS: EXTERIOR INSULATION

& FINISH SYSTEMINSUL: INSULATIONMECH: MECHANICALMFG: MANUFACTURERFFE: FINISH FLOOR ELEVATIONFIN: FINISHFLR: FLOORFRP: FIBERGLASS REINFORCED

PANELFT: FEETGC: GENERAL CONTRACTORGD: GRADE

GYP BD: GYPSUM BOARDHC: ACCESSIBLEHGT: HEIGHTHM: HOLLOW METALHVAC: HEATING, VENTILATING

& AIR CONDITIONINGHWY: HIGHWAYMTD: MOUNTEDOC: ON CENTERPL: PROPERTY LINEPLYWD: PLYWOODPP: POWER POLEPR: PAIRPSI: POUNDS PER SQUARE INCHPT: PAINTPTD: PAINTEDPVMT: PAVEMENTRCP: REFLECTED CEILING PLANREQ: REQUIREDSPECS: SPECIFICATIONSSQ: SQUARESTD: STANDARDSTRUCT: STRUCTURALTRANS: TRANSFORMERW/: WITHW/O: WITHOUTWD: WOODWH: WATER HEATERWWF: WELDED WIRE FABRIC

COLLIERVILLE, TENNESSEE

REMODELING SOON

38017

COVER SHEET

D1.0 DEMOLITION PLAN

6

4A4.0

A5.022

A0.0 SCOPE OF WORK

A1.1 ENLARGED PLAN, ELEVATIONS & DETAILS

SCOPE OF WORK & ALTERNATESSEE A0.0

A0.1 COLOR & FINISH SCHEDULES

REMODEL BUILDING AREA LIMITS

SALES FLOOR EXISTING 18,630 SQ. FT. / 30

22,712 SQ. FT.TOTAL BUILDING AREA EXISTING

OCCUPANCY LOAD

= 621.0 OR 621

MECHANICAL AND PLUMBING FLOOR PLANMP1.0

MECHANICAL & PLUMBING

STOCKROOM EXISTING 2,502 SQ. FT. / 300 = 8.3 OR 9

TOTAL OCCUPANT LOAD EXISTING = 653

CORE AREA EXISTING 1,300 SQ. FT. / 100 = 13.0 OR 13

VESTIBULE EXISTING 280 SQ. FT. / 30 =9.3 OR 10

PROJECT DATA

2018 INTERNATIONAL BUILDING CODE2018 INTERNATIONAL PLUMBING CODE2018 INTERNATIONAL MECHANICAL CODE2017 NATIONAL ELECTRIC CODE2018 INTERNATIONAL FIRE CODE2018 INTERNATIONAL FUEL GAS CODE

IIBFIRE SUPRESSIONCONSTRUCTION TYPEOCCUPANCY CLASSIFICATION

SPRINKLERED (EXISTING TO REMAIN)

MERCANTILE

PROJECT SUMMARY

ALARM SYSTEM ALARMED (EXISTING TO REMAIN)

NUMBER OF STORIES 1 (EXISTING TO REMAIN)

WALL TYPES

GENERAL LIGHTING PLANE1.0

ELECTRICAL

ELECTRICAL NOTES AND DETAILSE2.0

THIS PROJECT IS BASED ON THE REQUIREMENTS OF THE 2018 TENNESSEEBUILDING CODES WHICH IS BASED UPON THE FOLLOWING:

EXISTING WALL TO REMAIN

TRACTOR SUPPLY COMPANY IS REMODELING THIS STORE TO INCLUDE NEW ELECTRICAL UPDATES,TOUCHLESS FIXTURES, AND GENERAL UPKEEP TO THE BUILDING AS A PART OF THEIR NEW FUSIONINITIATIVE.

5/8" TYPE "X" GYP. BD. BOTH SIDES OF 3 5/8" METAL STUDSEXTEND 4" ABOVE CEILING TILE

AutoCAD SHX Text
5
AutoCAD SHX Text
1
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
6
Page 2: COLLIERVILLE, TENNESSEE REVISION DATE: …

RETAIL SALES102

STOCKROOM105

CORRIDOR106

MEN 109110

WOMEN

107

MANAGER'SOFFICE

EMPLOYEE

108LOUNGE

VESTIBULE101

FENCED OUTDOOR DISPLAY AREA

CONTRACTOR TO REMOVEOVERHEAD DOOR. PREP AREATO RECEIVE NEW WORK.

CONTRACTOR TO REMOVE LIGHTCOVERS, CEILING TILE, AND GRID.STORE LIGHTING TO BEREINSTALLED IN SAME LOCATION.

CONTRACTOR TO REMOVE LIGHTCOVERS, CEILING TILE, AND GRIDIN OFFICE CORE AREA. REPLACEALL LIGHT COVERS AND ANYDAMAGED, STAINED, OR MISSINGCEILING TILES IN CORRIDOR ASNECESSARY. STORE LIGHTING TOBE REINSTALLED IN SAMELOCATION.

CONTRACTOR TO REMOVESWING DOORS. PREP AREA TORECEIVE NEW WORK.

CONTRACTOR TO REMOVE TILEFLOORING AND SINK AND COUNTERUNIT. PREP AREA TO RECEIVE NEWWORK.

CONTRACTOR TO REMOVE CARPETFLOORING. PREP AREA TO RECEIVENEW WORK.

CONTRACTOR TO REMOVEDRINKING FOUNTAIN UNIT. PREPAREA TO RECEIVE NEW WORK.

CONTRACTOR TO REMOVE PLUMBINGFIXTURES, TOILET ACCESSORIES, ANDTILE FLOORING. URINAL TO REMAIN,SEE PLUMBING FOR NEW HARDWARE.PREP AREA TO RECEIVE NEW WORK.

CONTRACTOR TO REMOVE VINYLPLANK FLOORING FROM RIGHT SIDEOF THE STORE. PREP AREA FOR NEWWORK.

CONTRACTOR TO REMOVEPRE-FABRICATED DRESSING ROOMWALLS, DOORS, AND ACCESSORIES.REUSE ACCESSORIES WHENPOSSIBLE. PREP AREA TO RECEIVENEW WORK.

TRACTOR SUPPLY COMPANY

COLLIERVILLETENNESSEE

2934 Sidco DriveSuite 120Nashville, TN 37204

OXFORDARCHITECTURE

ArchitecturePlanning

Interior Architecture

D1.0

DEMOLITION PLAN1 DEMOLITION PLAN

SCALE: 3/32" = 1'-0"

AutoCAD SHX Text
Job Number:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Sheet Number:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
2000.064
AutoCAD SHX Text
11.23.2020
AutoCAD SHX Text
This drawing and the design shown is the property of the architect. The reproduction, copying or use of this drawing without their written consent is prohibited and any infringement will be subject to legal action.
AutoCAD SHX Text
All measurements and items portrayed on this sheet are deemed to be accurate by architect, however all bidding General Contractors should field verify the actual conditions. Any changes to the scope of work, and thus potential change orders, should be identified and communicated to TSC.
AutoCAD SHX Text
Tractor Supply Company shall not be responsible for the payment of any work performed or material supplied by the Contractor or any of its sub-contractors, sub-subcontractors and anyone claiming by through or under any of them which is not identified in writing and signed by one of the following Tractor Supply Company personnel: Vice President Real Estate, Vice President of Construction, or a Construction Project Manager. No action, conduct, omission, prior failure, or course of dealing by Tractor Supply Company shall act to waive, modify, change or alter the requirement that all work, whether by contract, change order or change directive, must be in writing and signed by the personnel identified in this provision. Any work performed or material provided by the Contractor, any of its sub-contractors, sub-subcontractors contrary to this provision shall be at its own risk and own expense and Tractor Supply Company shall not be obligated to reimburse or pay the Contractor or any of its sub-contractors, sub-subcontractors for same.
Page 3: COLLIERVILLE, TENNESSEE REVISION DATE: …

SCOPE OF WORK & ALTERNATES

TRACTOR SUPPLY COMPANY

COLLIERVILLETENNESSEE

2934 Sidco DriveSuite 120Nashville, TN 37204

OXFORDARCHITECTURE

ArchitecturePlanning

Interior Architecture

A0.0

SCOPE OF WORK

AutoCAD SHX Text
Job Number:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Sheet Number:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
2000.064
AutoCAD SHX Text
11.23.2020
AutoCAD SHX Text
This drawing and the design shown is the property of the architect. The reproduction, copying or use of this drawing without their written consent is prohibited and any infringement will be subject to legal action.
AutoCAD SHX Text
All measurements and items portrayed on this sheet are deemed to be accurate by architect, however all bidding General Contractors should field verify the actual conditions. Any changes to the scope of work, and thus potential change orders, should be identified and communicated to TSC.
AutoCAD SHX Text
Tractor Supply Company shall not be responsible for the payment of any work performed or material supplied by the Contractor or any of its sub-contractors, sub-subcontractors and anyone claiming by through or under any of them which is not identified in writing and signed by one of the following Tractor Supply Company personnel: Vice President Real Estate, Vice President of Construction, or a Construction Project Manager. No action, conduct, omission, prior failure, or course of dealing by Tractor Supply Company shall act to waive, modify, change or alter the requirement that all work, whether by contract, change order or change directive, must be in writing and signed by the personnel identified in this provision. Any work performed or material provided by the Contractor, any of its sub-contractors, sub-subcontractors contrary to this provision shall be at its own risk and own expense and Tractor Supply Company shall not be obligated to reimburse or pay the Contractor or any of its sub-contractors, sub-subcontractors for same.
Page 4: COLLIERVILLE, TENNESSEE REVISION DATE: …

COLOR SCHEDULE

HARDWARE SETSIZE

DOOR SCHEDULE

10'-0" X 10'-0"

PR 3'-0"X8'-0"

13

MARK

6

E MTL.

MATERIAL

ALUM. / GLASS

TYPE

D

FRAME

MTL.

SEE NOTES 1 & 22

REMARKS

2

INSUL MTL.

NOTE: TRACTOR SUPPLY COMPANY HAS A NATIONAL ACCOUNT WITH DH PACE FOR DOOR HARDWARE.CONTACT: CHARLES GIRTMAN @ [email protected] OR #816.221.0543

6, 13

SEE NOTE 3

JOHNSONITE VINYL #40 BLACK IN ALL SPACES W/ PREFORMED INSIDE AND OUTSIDE CORNERSVINYL BASE

HIGH GLOSS FINISH - COLOR TO MATCH SW4081 SAFETY RED FROM 10'-0" A.F.F. TO 10'-8" A.F.F., FRONT, LEFT, AND RIGHT SIDES 2 COATS: S-W ACROLON 100, B65R720 PART A SAFETY RED/ B65V720 PART B HARDENER - APPLY AS NEEDED FOR COMPLETE COVERAGE)

INTERIOR FINISHES:

EXTERIOR BUILDING FINISHES:

(CONCRETE MASONRY UNITS)RED ACCENT STRIPE

GLOSS FINISH - COLOR TO MATCH SW1012 POWER GREY 1ST COAT: S-W KEM KROMIK UNIVERSAL METAL PRIMER, B50Z

SERIES - OMIT FOR H.M. DOOR FRAMES (6.0 - 8.0 MLS WET / 3.0 -4.0 MLS DRY PER COAT) 2ND COAT: S-W INDUSTRIAL ENAMEL HS, B54Z400 SERIES 3RD COAT: S-W INDUSTRIAL ENAMEL HS, B54Z400 SERIES (2.0 - 4.0 MILS DRY PER COAT) (APPLY AS NEEDED FOR COMPLETE COVERAGE)

APPLY TO EXTERIOR RED STRIPE ONLY - CLEAR COAT GLOSS FINISH - DIAMOND-CLAD WB 3 COMPONENT, LOW VOC WATERBASED ACRYLIC POLYURETHANE CLEAR COAT DIAMOND-CLAD CLEAR COAT URETHANE GLOSS CLEAR PART A (B65T175) DIAMOND-CLAD CLEAR COAT URETHANE HARDNER PART B (B65V175) DIAMOND-CLAD CLEAR COAT URETHANE CATALYST PART C (B65C175)MIX COMPONENTS PER MANUFACTURERS SPECIFICATIONS COAT ACROLON WITHIN 48 HOURS RECOMMENDED SPREAD RATE (WET MILS: 2.4-4.8 AND DRY MILS: 1.0-2.0)

RED STRIPE (AROUND VESTIBULE BUMP OUT) - BY POP SOLUTIONS TO MATCH RED STRIPE SW 4081 SAFETY RED

NOTE: APPLICATIONS MAYUTILIZE BRUSH, ROLLEROR AIRLESS SPRAYER;HOWEVER, ALL COATSMUST BE BACK-ROLLED.SEE SHERWIN WILLIAMSDATA SHEET APPLICATIONRECOMMENDATIONS

NOTE: APPLICATIONS MAY UTILIZEBRUSH, ROLLER OR AIRLESSSPRAYER; HOWEVER, ALL COATSMUST BE BACK-ROLLED. SEESHERWIN WILLIAMS DATA SHEETAPPLICATION RECOMMENDATIONS

CONCRETE MASONRY UNITS AND EXTERIOR CONCRETE MOISTURE CONTENT CRITERIA.GENERAL CONTRACTOR, OR, THE OWNERS TESTING COMPANY SHALL PROVIDE MOISTURE TESTING OF ALL CMU AND CONCRETE EXTERIORWALL PER ASTM D4263 PRIOR TO APPLICATION OF PAINT. TSC PROJECT MANAGER MUST APPROVE THE APPLICATION OF PAINT IN WRITING,IF THE MOISTURE CONTENT IS ABOVE 15%.

LOADING DOCK GUARDRAILS AND HOLLOW METAL DOOR FRAMES

6 FRAME SUPPLIED BY TSC, INSTALLED BY CONTRACTOR

DOOR TYPES

DOOR NOTESHOLLOW METAL DOORSPAINTED SHER-CRYL HPA SW1012 POWER GRAY

H.M. AND WOOD DOORS COLOR TO MATCH SW1012 POWER GRAY

DOORSSET # QUANTITY ITEM MANUFACTURER2 ALL HARDWARE BY DOOR SUPPLIER

'D' 'E'

1'-0

" 3'-6

"

(COLOR TO MATCH SW1012, POWER GREY)EXTERIOR METAL AND INTERIOR WOOD DOORS:

(COLOR TO MATCH SW7513, SANDERLING@ DRESSING ROOM DOOR ONLY)

PIPE BOLLARDS AND COVERS 6" SCHEDULE 40 CONCRETE FILLED PIPE BOLLARD WITH MCCUE POST COVER CSPC-6-307(SEE MANUFACTURER FOR BOLLARD SIZES OTHER THAN 6" DIA.) COLOR TO BE STANDARD YELLOW

NOTE: CONTRACTOR TO ACCESSA0.0_ASD1.PDF ON PLAN EXPRESSFOR ALTERNATE PAINTSPECIFICATION BY PPG.

SEMI-GLOSS FINISH - SW 4081 SAFETY RED 1ST COAT: S-W PROMAR 200 ZERO VOC INTERIOR LATEX PRIMER, B28W02600 (4 MILS. WET, 1.2 MILS DRY) 2ND COAT: S-W PROMAR 200 ZERO VOC INTERIOR LATEX SEMI-GLOSS, B31R02658 3RD COAT: S-W PROMAR 200 ZERO VOC INTERIOR LATEX SEMI-GLOSS, B31R02658

RED ACCENT STRIPE (IN RETAIL SALES AREA - 10'-3" TO BOTTOM OF STRIPE, 12" STRIPE)

GLOSS FINISH - COLOR TO MATCH SW1012, POWER GREY 1ST COAT: S-W KEM KROMIK UNIVERSAL METAL PRIMER, B50Z SERIES (6.0 - 8.0 MILS WET / 3.0 - 4.0 MILS DRY PER COAT) 2ND COAT: S-W PROMAR 400 ZERO VOC INTERIOR LATEX

SEMI-GLOSS, B31W04651 SERIES 3RD COAT: S-W PROMAR 400 ZERO VOC INTERIOR LATEX

SEMI-GLOSS, B31W04651 SERIES (4 MILS WET, 1.3 MILS DRY PER COAT)

GLOSS FINISH - COLOR TO MATCH SW1012, POWER GREY COLOR TO MATCH SW7513, SANDERLING - @ DRESSING ROOM DOOR ONLY

1ST COAT: FACTORY PRIMED 2ND COAT: S-W PROMAR 400 ZERO VOC INTERIOR LATEX SEMI-GLOSS,

B31W04651 SERIES 3RD COAT: S-W PROMAR 400 ZERO VOC INTERIOR LATEX SEMI-GLOSS,

B31W04651 SERIES (4 MILS WET, 1.3 MILS DRY PER COAT)

METAL DOOR FRAMES

INTERIOR COLUMNS (METAL)

SEMI-GLOSS FINISH - COLOR TO MATCH SW7005 PURE WHITE 1ST COAT: S-W PREPRITE BLOCK FILLER B25W25 (75-125 SQ. FT./GAL @ 16 MILS WET; 8 MILS DRY) 2ND COAT: S-W PROMAR 400 ZERO VOC INTERIOR LATEX SEMI-GLOSS, B31W04651 SERIES 3RD COAT: S-W PROMAR 400 ZERO VOC INTERIOR LATEX SEMI-GLOSS, B31W04651 SERIES (4 MILS WET, 1.3 MILS DRY PER COAT)

MASONRY (CONCRETE, SCORED, SMOOTH, HIGH/LOW DENSITY)

CONCRETE MASONRY UNITS FOR CONVENTIONAL BUILDINGS.ELASTOMERIC SYSTEM

LIGHTING POLE BASES

SEMI-GLOSS FINISH - (COLOR TO MATCH SW7036 ACCESSIBLE BEIGE.) 1ST COAT: S-W PROMAR 200 ZERO VOC INTERIOR LATEX PRIMER,

B28W02600 (4 MILS WET, 1.3 MILS DRY PER COAT) 2ND COAT: S-W PROMAR 400 ZERO VOC INTERIOR LATEX SEMI-GLOSS,

B31W04651 SERIES 3RD COAT: S-W PROMAR 400 ZERO VOC INTERIOR LATEX SEMI-GLOSS,

B31W04651 SERIES (4 MILS WET, 1.3 MILS DRY PER COAT)

OUTER CORE AREAS

INNER CORE AREAS

SEMI-GLOSS FINISH - (COLOR TO MATCH SW7005 PURE WHITE.) 1ST COAT: S-W PROMAR 200 ZERO VOC INTERIOR LATEX PRIMER,

B28W02600 (4 MILS WET, 1.3 MILS DRY PER COAT) 2ND COAT: S-W PROMAR 400 ZERO VOC INTERIOR LATEX SEMI-GLOSS,

B31W04651 SERIES 3RD COAT: S-W PROMAR 400 ZERO VOC INTERIOR LATEX SEMI-GLOSS,

B31W04651 SERIES (4 MILS WET, 1.3 MILS DRY PER COAT)

FLAT FINISH - FRONT FACADE COLOR TO MATCH SW7513 SANDERLING TO 4'-0" A.F.F., SW7532URBAN PUTTY FROM 4'-0" A.F.F. TO TOP OF C.M.U. , ALL SIDES. 1ST COAT: S-W LOXON ACRYLIC BLOCK SURFACER, LX01W0200 (50-100 SQ FT/ GAL @ 16 MILS

WET; 8 MILS DRY) 2ND COAT: S-W CONFLEX XL SMOOTH HIGH BUILD ACRYLIC COATING, CF11 SERIES 3RD COAT: S-W CONFLEX XL SMOOTH HIGH BUILD ACRYLIC COATING, CF11 SERIES (16 MILS WET, 7.5 MILS PER DRY COAT) (ACCEPTABLE TOLERANCE IS 9-10 PINHOLES PER SQ. FT.)

1ST COAT: S-W PREPRITE 200 ZERO VOC INTERIOR LATEX PRIMER, B28W02600

(4 MILS WET, 1.3 MILS DRY PER COAT) TSC TO PROVIDE AND INSTALL WALLPAPER

OUTER DRESSING ROOM WALLS

GLOSS FINISH - COLOR TO MATCH SW1012, POWER GREYCOLOR TO MATCH SW7513, SANDERLING -@ DRESSING ROOM DOOR ONLY

1ST COAT: PAINTED 2ND COAT: S-W PRO INDUSTRIAL WATERBASED ALKYD

URETHANE ENAMEL B53W01051 SERIES 3RD COAT: S-W PRO INDUSTRIAL WATERBASED ALKYD

URETHANE ENAMEL B53W01051 SERIES (4 MILS WET, 1.6 MILS DRY PER COAT)

METAL DOOR FRAMES - OPTION (HARDER FINISH AND BETTERCOLOR/GLOSS RETENTION)

PLASTIC LAMINATE - WILSONART 4857-60 SHADOW ZEPHYR AT EMPLOYEE LOUNGE COUNTERTOP PROVIDED BY TSC

RETAIL SALES TO BE PAINTED DOWN TO 7' A.F.F. BEHIND FIXTURES, AND 12' AROUND OPENINGS

LAYIN CEILINGS & GRID (OFFICE CORE) ARMSTRONG DUNE 1776 2X4, WHITE, SQUARE LAYIN, OR EQUAL

LAYIN CEILINGS & GRID (VESTIBULE) GRID STONE GYPSUM CEILING PANELS 1/2" X 2' X 4'

FIBERGLASS REINFORCED PANEL (FRP) - BY GLASTEEL, GLASLINER FRP,COLOR: XA WHITE, FINISH: TEXTURED. INSTALL AS WAINSCOT TO 4'A.F.F. ON ALL WALLS ADJACENT TO THE WATER COOLER AND ON ALL NON-MASONRY WALLS IN RESTROOMS. SEE DETAILS A5.0 FOR MOPSINK CONDITION. SEE DETAILS A5.1 FOR PET WASH WALL CONDITION.

DOOR NOTES:1. NEW FLEX DOOR W/ ELECTRIC OPERATOR, (2) RADIO REMOTES, TIMER, CHAIN KEEPER AND REVERSING SAFETY EDGE. OVERRIDE BUTTON TO BE SUPPLIED BY

OVERHEAD DOOR VENDOR AND INSTALLED BY GENERAL CONTRACTOR'S ELECTRICIAN. COLOR TO BE FACTORY FINISHED WHITE.2. CONTRACTOR TO INSTALL PLASTIC AIR CURTAIN WITH 50% PANEL OVERLAP @ INSIDE NEW DOOR. AIR CURTAIN INCLUDED WITH OVERHEAD DOOR VENDOR

PACKAGE.3. 72" X 96", 72" X 84" OR 36" X 96" OPENINGS TO BE PROVIDED AS: P11PLUS, WITH 10" X 30" ADA COMPLIANT WINDOWS, 18" TALL BUMPERS, COLOR: RED. (OR)

OPENINGS 96" X 120" TO BE: DURULITE STANDARD DOORS WITH 20" X 30" ADA COMPLIANT WINDOWS, 36" TALL BUMPERS, COLOR: RED.

FLOOR IN VESTIBULE,SALES, STOCKROOM,CORRIDOR, RESTROOMS,EMPLOYEE LOUNGE,MANAGER'S OFFICE

CONCRETE FLOORING SPECIFICATIONS, PROVIDE THE FOLLOWING:

· ANY FLOOR AREAS OVER 3" ROUND WILL BE PREPPED BY THE "GC".· MECHANICALLY GROUND AND POLISHED FLOOR SURFACE TO A 400 GRIT RESIN

DIAMOND FOLLOWED BY 800 GRIT DIAMOND PAD BURNISH FOR A MID LEVELGLOSS. INCLUDED IN THIS PROCESS IS CONCRETE DENSIFICATION,JOINT/CRACK FILLING UP TO 1150 LF AND PATCHING OF HOLES SMALLER THAN3" THAT POSE A TRIP HAZARD.

MANAGER'S OFFICE

EMPLOYEE LOUNGE

NOT USED

DRESSING ROOM

FINISH SCHEDULE

110

109

WOMEN

MEN

CORRIDOR106

108

107

105

104

STOCKROOM

VESTIBULE101

103

102 RETAIL SALES

NO. ROOM

A.C.T. @ 8'-0"

A.C.T. @ 8'-0"

GYP. BD. CEILING PANELS @ 10'-0" A.F.F.

PTD. GYP. / C.M.U. / PLYWOOD

PTD. GYP./ FRP

PTD. GYP.

PTD. GYP.

(SEMI-GLOSS, WHITE)A.C.T. @ 8'-0"

A.C.T. @ 8'-0"

A.C.T. @ 8'-0"

PTD. GYP. / C.M.U.PTD. C.M.U. / STOREFRONT

(SEMI-GLOSS, WHITE)

WALLS

EXP. STRUCTURE FACTORY PRIMED (GRAY)

CEILING

VINYL

VINYL

VINYL

-

FLOOR-

VINYL

BASE

1, 4, 5, 9

1, 4, 7, 9

1, 4, 9

9

6, 9

3, 9

REMARKS

PTD. GYP./C.M.U./ FRP

PTD. GYP./C.M.U./ FRP

EXP. STRUCTURE FACTORY PRIMED (GRAY)

VINYL

VINYL

1. CEILING TILE: 2' x 4' X 3/4" MINERAL BOARD, NON-DIRECTIONAL FISSURED, MEDIUM TEXTURE, FLAME RESISTANCE CLASS A, FLAME SPREADCLASS I

2. VINYL PLANK: EARTHWERKS "WOOD CLASSIC" GWC 9812. DELIVERED BY TSC, SUPPLIED, PURCHASED AND INSTALLED BY CONTRACTOR.BEVELED EDGE VINYL PLANK TO BE USED AT EXPOSED TRANSITION OF VINYL PLANK FLOORING TO CONCRETE.

3. RED ACCENT STRIPE @ 10'-3" FROM FINISH FLOOR TO BOTTOM OF STRIPE -1'-0" STRIPE4. WALL COLOR TO BE (SW7036 ACCESSIBLE BEIGE). TRIM AND DOORS TO BE (SW1012 POWER GRAY).5. FRP WAINSCOT TO BE INSTALLED ON ALL NON-MASONRY WALLS 4'-0" A.F.F. COLOR: XA WHITE, FINISH: TEXTURED.6. GRID STONE GYPSUM CEILING PANELS 1/2" X 2' X 4'7. FRP WAINSCOT TO BE INSTALLED BEHIND AND ON ALL SIDES OF THE WATER COOLER ALCOVE TO 4'-0" A.F.F. COLOR: XA WHITE, FINISH:

TEXTURED.8. INTERIOR DRESSING ROOM WALLS TO BE PURE WHITE. EXTERIOR WALL EXTENDING ABOVE 9'-0" A.F.F. TO BE PAINTED PURE WHITE W/ RED

STRIPE TO MATCH RETAIL SALES WALLS. EXTERIOR DRESSING ROOM WALLS TO BE WALLPAPER PROVIDED AND INSTALLED BY TSC.9. SEE CONCRETE FINISHING REQUIREMENTS THIS SHEET.10. VINYL TILE TO MATCH AZROCK V-862 CLOUD WHITE OR ARMSTRONG 51899 COOL WHITE.

1, 4, 5, 9

1, 4, 9

PTD. GYP. / C.M.U. VINYL PLANK 2, 8OPEN TO A.C.T. ABOVE VINYL

DRYWALL AND INTERIOR DRESSING ROOM WALLS(WALLS, GYPSUM BOARD, PLASTER BOARD, ETC.)

GLOSS FINISH - COLOR TO BE SW4084 SAFETY YELLOW 1ST COAT: S-W LOXON ACRYLIC BLOCK SURFACER,

LX01W0200 (50-100 SQ FT/ GAL @ 16 MILS WET;8 MILS DRY)

2ND COAT: S-W CONFLEX XL SMOOTH HIGH BUILD ACRYLICCOATING, CF11 SERIES

3RD COAT: S-W CONFLEX XL SMOOTH HIGH BUILD ACRYLICCOATING, CF11 SERIES

(APPLY AS NEEDED FOR COMPLETE COVERAGE) PRODUCT IS PACKAGE SAFETY YELLOW; COLOR

ACCEPTANCE SHOULD BE APPROVED BY TRACTOR SUPPLY.

CONDUIT IN CLOTHING AREA CONDUIT ON EXTERIOR WALLS IN CLOTHING AREA RUST-OLEUM UNIVERSALHAMMERED ALL SURFACE PAINT + PRIMER COLOR: BROWN

TRACTOR SUPPLY & VENDOR CONTACT INFORMATION

CONCRETEGRIND & POLISH

INSTALL NEW

CONCRETECRACK FILL/PATCH

CONCRETEGRIND & POLISH

CONCRETEGRIND & POLISH

CONCRETEGRIND & POLISH

CONCRETEGRIND & POLISH

CONCRETEGRIND & POLISH

'H'

8"5'

-8"

8"

4 3'-0" X 5'-8" H H. MTL. 4S.C. WOOD

44 CONTINUOUS HINGE MCK-22HD 66-CLEARPRIVACY SET T301S X D X 23981137 X 5164 X 1 3/4- 626WALL STOP WS407- CCV-US32DSILENCER SR64- GRY

MCKFALIVEIVE

1 EA.1 EA.1 EA.2 EA.

TRACTOR SUPPLY FIXTURE PLANS

PRINTING

KEN MARSH#[email protected]

CINDY PINDPLAN EXPRESS#[email protected]

VICKY DERON#[email protected]

BUMPER SIGNS / BOLLARD COVERSKEVIN O'NEILLMCCUE#[email protected]

DOORS, FRAMES, & DOOR HARDWARE

SECTIONAL DOORS

TRAVIS SMITHDH PACE#[email protected]@dhpace.comLEAD TIME:

2-3 WEEKS - SECTIONAL & COILING DOORS*USE COILING DOORS IN HIGH IMPACT REGIONS

SAMI TOTTEN - PROJECT MANAGERDH PACE#[email protected]@dhpace.comLEAD TIME:

2 WEEKS - HOLLOW METAL FRAMES3 WEEKS - PRE-PAINTED & HPI DOORS3-4 WEEKS - WIND RATED ASSEMBLIES & COASTAL /

CA PROJECTS

CHARLES GIRTMAN, NATIONAL ACCOUNT SALES EXECUTIVEDH PACE#[email protected]

ADAM POSLOSKYDH PACE#[email protected]@dhpace.com

LIGHTING PROVIDERBRYAN BIRDWELLVILLA LIGHTING SUPPLY, INC.#[email protected] TIME:

3-5 DAYS - INT/EXT LIGHTING3-4 WEEKS - SITE POLE LIGHTING

ANNE VOELKER, PRICING CONTACTVILLA LIGHTING SUPPLY, INC.#[email protected] TIME:

3-5 DAYS - INT/EXT LIGHTING3-4 WEEKS - SITE POLE LIGHTING

RED STRIPINGRICK TOWNEPOP SOLUTIONS GROUP#901.483.5929 (CELL)#901.795.5936 x 19 (OFFICE)[email protected]

GAGE PERRYPHILIPS TELETROL#[email protected]

LOW VOLTAGE PROVIDERTERRY L CORPENINGMERCURY TECH PARTNERS, INC.#828.465.7348 x [email protected]

DUANE MULLINSMERCURY TECH PARTNERS, INC.#828.465.7348 x [email protected]

EMS

HAND DRYERSASHLEY MAYWORLD DRYERS DISTRIBUTOR#[email protected]

VINYL PLANK FLOORINGLUCINDA BARRIENTOSEARTHWERKS/ SWIFF-TRAIN#1.800.929.1222 x [email protected]

CONCRETEGRIND & POLISH

TRACTOR SUPPLY COMPANY

COLLIERVILLETENNESSEE

2934 Sidco DriveSuite 120Nashville, TN 37204

OXFORDARCHITECTURE

ArchitecturePlanning

Interior Architecture

A0.1

DOOR & FINISH SCHEDULES

AutoCAD SHX Text
Job Number:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Sheet Number:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
2000.064
AutoCAD SHX Text
11.23.2020
AutoCAD SHX Text
This drawing and the design shown is the property of the architect. The reproduction, copying or use of this drawing without their written consent is prohibited and any infringement will be subject to legal action.
AutoCAD SHX Text
All measurements and items portrayed on this sheet are deemed to be accurate by architect, however all bidding General Contractors should field verify the actual conditions. Any changes to the scope of work, and thus potential change orders, should be identified and communicated to TSC.
AutoCAD SHX Text
Tractor Supply Company shall not be responsible for the payment of any work performed or material supplied by the Contractor or any of its sub-contractors, sub-subcontractors and anyone claiming by through or under any of them which is not identified in writing and signed by one of the following Tractor Supply Company personnel: Vice President Real Estate, Vice President of Construction, or a Construction Project Manager. No action, conduct, omission, prior failure, or course of dealing by Tractor Supply Company shall act to waive, modify, change or alter the requirement that all work, whether by contract, change order or change directive, must be in writing and signed by the personnel identified in this provision. Any work performed or material provided by the Contractor, any of its sub-contractors, sub-subcontractors contrary to this provision shall be at its own risk and own expense and Tractor Supply Company shall not be obligated to reimburse or pay the Contractor or any of its sub-contractors, sub-subcontractors for same.
Page 5: COLLIERVILLE, TENNESSEE REVISION DATE: …

RETAIL SALES102

STOCKROOM105

CORRIDOR106

MEN 109110

WOMEN

107

MANAGER'SOFFICE

EMPLOYEE

108LOUNGE

VESTIBULE101

FENCED OUTDOOR DISPLAY AREA

NOTE:FINAL FIXTURE PLAN TO BE DEVELOPEDBY TSC. SERVICE DESK, FIXTURES ANDCOUNTERS TO BE SUPPLIED BY TSCAND INSTALLED BY CONTRACTOR.

1A1.1

13

6

CONTRACTOR TO INSTALL NEWLIGHT COVERS, CEILING TILE, ANDGRID. STORE LIGHTING TO BEREINSTALLED IN SAME LOCATION.

CONTRACTOR TO INSTALL NEWLIGHT COVERS, CEILING TILE, ANDGRID IN OFFICE CORE AREA. STORELIGHTING TO BE REINSTALLED INSAME LOCATION.

9A1.1

4

7A1.1

TRACTOR SUPPLY COMPANY

COLLIERVILLETENNESSEE

2934 Sidco DriveSuite 120Nashville, TN 37204

OXFORDARCHITECTURE

ArchitecturePlanning

Interior Architecture

A1.0

ARCHITECTURAL FLOOR PLAN

1 ARCHITECTURAL FLOOR PLANSCALE: 3/32" = 1'-0"

AutoCAD SHX Text
K-2005
AutoCAD SHX Text
KINGSTON
AutoCAD SHX Text
C_LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
K-2005
AutoCAD SHX Text
KINGSTON
AutoCAD SHX Text
C_LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
Job Number:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Sheet Number:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
2000.064
AutoCAD SHX Text
11.23.2020
AutoCAD SHX Text
This drawing and the design shown is the property of the architect. The reproduction, copying or use of this drawing without their written consent is prohibited and any infringement will be subject to legal action.
AutoCAD SHX Text
All measurements and items portrayed on this sheet are deemed to be accurate by architect, however all bidding General Contractors should field verify the actual conditions. Any changes to the scope of work, and thus potential change orders, should be identified and communicated to TSC.
AutoCAD SHX Text
Tractor Supply Company shall not be responsible for the payment of any work performed or material supplied by the Contractor or any of its sub-contractors, sub-subcontractors and anyone claiming by through or under any of them which is not identified in writing and signed by one of the following Tractor Supply Company personnel: Vice President Real Estate, Vice President of Construction, or a Construction Project Manager. No action, conduct, omission, prior failure, or course of dealing by Tractor Supply Company shall act to waive, modify, change or alter the requirement that all work, whether by contract, change order or change directive, must be in writing and signed by the personnel identified in this provision. Any work performed or material provided by the Contractor, any of its sub-contractors, sub-subcontractors contrary to this provision shall be at its own risk and own expense and Tractor Supply Company shall not be obligated to reimburse or pay the Contractor or any of its sub-contractors, sub-subcontractors for same.
Page 6: COLLIERVILLE, TENNESSEE REVISION DATE: …

A1.1

5

MEN'S109

WOMEN'S110

MANAGER'SOFFICE107

EMPLOYEELOUNGE108

CORRIDOR106

COUNTER, SEEDETAIL 6/A1.1

DF

4

3

2A1.1

STOCKROOM105

EXISTING OPENING

SEALANT @DISSIMILAR MATERIALS

STEEL CHANNEL PAINTED,WIDTH TO MATCH WALLTHICKNESS. PROVIDE 1/2"ANCHOR TO BLOCK @ 48"O.C. VERT. GROUT FILL

EXISTING PIPE BOLLARDS TO REMAIN

DOOR TRACK, SEE MANUF.

3'-0

"

40" M

AX.

1'-5"

4" VINYL BASE

PAPER TOWEL DISPENSERMTD. OVER COUNTER

TSC PROVIDED SINK,SEE PLUMBING

TSC PROVIDED CABINETS

TSC PROVIDED ADACOMPLIANT CABINET

WATER & WASTE LINEWRAP 102G BYTRUEBRO, INC.

TSC PROVIDEDCABINET

1'-8

"

5'-0

"

TSC PROVIDED SHELF ANDBRACKETS

GC TO COORDINATE ALLIN-WALL BLOCKINGREQUIREMENTS

GFI

C

E

D

A

B

F

G

MIRROR (1/4" POLISHED PLATE GLASS) 1 PIECE, 18 x 36

TOILET ACCESSORIES SCHEDULE

TOILET PAPER DISPENSER

SOAP DISPENSER

GRAB BAR

TYPE MODEL #

F.B.O., I.B.C.

MANUF.F.B.O., I.B.C.

BRADLEY8320-001-368320-001-42

40" MAX. TO CONTROL

REFLECTIVE SURFACE

MOUNTING HT.

33" - 36" TO TOP, MAX.

8320-001-18 39" - 41" TO BOTTOM33" - 36" TO TOP, MAX.

40" TO BOTTOM OF

NOT USED

NOTE:1. ALL HAND DRYERS, MIRRORS, AND GRAB BARS TO BE PROVIDED AND INSTALLED BY GC. TSC

IS NOT RESPONSIBLE.2. F.B.O., I.B.C. (FURNISHED BY OWNER; INSTALLED BY CONTRACTOR)3. FLUSH CONTROL SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET PER

ICC/ANSI 117.1 SECTION 604.6.4. FRP TO 4'-0" A.F.F. ON ALL WALLS EXCEPT CMU UNLESS NOTED OTHERWISE.5. ALL PLUMBING FIXTURES TO BE ANCHORED PER ALL ANCHOR POINTS.6. PROVIDE CEILING BATT INSULATION FOR RESTROOMS.7. NO ITEMS SHALL BE LOCATED FROM FLOOR TO CEILING WITHIN 18" OF THE EDGE OF THE

PULL-SIDE OF THE BATHROOM DOORS.

PAPER TOWEL DISPENSER 40" MAX. TO CONTROLF.B.O., I.B.C.

SMARTDRI PLUS WORLD DRYER UNIT40" TO BOTTOM OFK-974P2

CONTRACTOR TO UTILIZE TOILET ACCESSORIES SCHEDULE AS NECESSARY.

VITREOUS CHINATOILETHIGHLINEK-3519

15" M

IN.39" T

O 4

1"

33" -

36"

TO

TO

PO

F G

RAB

BAR

7" TO 9"

17" M

IN. T

O19

" MAX

.

39" TO 41"

B

18" M

IN.

11 2"M

IN.

42" MIN.

A

VINYL BASE

SW7036 ACCESSIBLE BEIGE

12" MAX.

B

FRP WAINSCOT TO 4'-0" A.F.F

LC

VINYL BASE

E

1'-6"

SW7036 ACCESSIBLE BEIGE

C

34" M

AX.

27" M

IN.

29" M

IN.

G

40" M

AX.

TO R

EFLE

CTI

VE S

URF

ACE

A

B

15" M

IN.

33" -

36"

TO

TO

PO

F G

RAB

BAR

36" MAX.

1'-6" MAX.1'-4" MIN.

LC TOILET

12" MIN.

BOTTOM OF REFLECTIVE SURFACE@ MIRROR & SOAP DISPENSER

ELECTRIC HAND DRYER

16" X 36" STAINLESS STEELPANEL UNDER HANDDRYER PROVIDED ANDINSTALLED BY G.C.

CLEAR SEALANT AROUND ALL 4SIDES OF MIRROR @ WALL TOCREATE WATER TIGHT SEAL

FRP WAINSCOT TO 4'-0" A.F.F

SW7036ACCESSIBLE BEIGE

9" M

IN.

FRP WAINSCOT TO 4'-0"A.F.F. ADD CLEARSEALANT @ ALL SEAMSAND CORNERS

27" M

IN.

36" M

AX.

9" M

IN.

8" MIN. 6" MAX.

11" MIN.

4" MAX.

VINYL BASE

15" MIN.

15" MIN.

CL

CL

CORNER GUARDS @OUTSIDE CORNERS

5/8" GYP. BD. ON 3-5/8" METAL STUDS @16" O.C. FILL VOID WITH INSULATION

NOTE: CONTRACTOR TO BUILD DRESSING ROOM @ FRONT OF BUILDING ON LEFT SIDE. G.C. TO BUILDADA COMPLIANT BENCH COVERED WITH LVT TO MATCH NEW CLOTHING DEPARTMENT FLOORING.

PROVIDE (4) FOUR HOOKS ON DRESSINGROOM WALL. SEE NOTE A1.0

PROVIDE (2) TWO 24" x 60"MIRRORS, ONE ON THEEXTERIOR SIDE OF ROOM ANDONE ON THE INTERIOR WALLPARALLEL TO THE FRONT WALL.SEE NOTE A1.0, SEE A4.0

DRESSINGROOM104

4

NOTE: PERIMETER WALLS OFDRESSING ROOM TO EXTEND TO9'-0" A.F.F. CAP AND FINISH TOPOF WALL WITH GYP. BD.

8A1.1 R2'-6"

3'-4

"2'

-8"

4'-3" 2'-8"

1'-8"3'

-6"

2'-6

"

4"

4'-0"

3'-0"

4'-0"

ROOM SIGNAGE LOCATION

FIRE EXTINGUISHER, MOUNTPER AHJ

4"

20"

3/4" FINISH GRADEPLYWOOD

17"

2' X 2"

FLOOR

WALL

SECURE FRAMINGTO WALL

2 x 4 BLOCKING

1x6 APPLIED WOODTRIM W/ 0.25" RADIUSAT TOP EDGE

3/4" FINISH GRADEPLYWOOD

INSTALL LVT OVERPLYWOOD

27" M

IN.

29" M

IN.

34" M

AX.

74" M

IN.

40" M

AX.

EBOTTOM OF REFLECTIVE SURFACE@ MIRROR & SOAP DISPENSER

SW7036 ACCESSIBLE BEIGE

ELECTRIC HAND DRYER

FRP WAINSCOT TO 4'-0" A.F.F

VINYL BASE

G

C

TRACTOR SUPPLY COMPANY

COLLIERVILLETENNESSEE

2934 Sidco DriveSuite 120Nashville, TN 37204

OXFORDARCHITECTURE

ArchitecturePlanning

Interior Architecture

A1.1

ENLARGED PLAN, ELEVATIONS & DETAILS

1 ENLARGED RESTROOM PLANSCALE: 1/4" = 1'-0"9 DETAIL

SCALE: 1 1/2" = 1'-0"

@ EXISTING OVERHEAD DOOR JAMB

6 ELEVATIONSCALE: 1/2" = 1'-0"

@ BREAK ROOM COUNTER

3 ELEVATIONSCALE: 1/2" = 1'-0"

@ WOMEN'S RESTROOM

2 ELEVATIONSCALE: 1/2" = 1'-0"

@ WOMEN'S RESTROOM

5 ELEVATIONSCALE: 1/2" = 1'-0"

@ DRINKING FOUNTAIN

7 ENLARGED DRESSING ROOM PLANSCALE: 3/8" = 1'-0"

8 SECTIONSCALE: 1 1/2" = 1'-0"

DRESSING ROOM BENCH

4 ELEVATIONSCALE: 1/2" = 1'-0"

@ WOMEN'S RESTROOM

AutoCAD SHX Text
K-2005
AutoCAD SHX Text
KINGSTON
AutoCAD SHX Text
C_LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
K-2005
AutoCAD SHX Text
KINGSTON
AutoCAD SHX Text
C_LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
Job Number:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Sheet Number:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
2000.064
AutoCAD SHX Text
11.23.2020
AutoCAD SHX Text
This drawing and the design shown is the property of the architect. The reproduction, copying or use of this drawing without their written consent is prohibited and any infringement will be subject to legal action.
AutoCAD SHX Text
All measurements and items portrayed on this sheet are deemed to be accurate by architect, however all bidding General Contractors should field verify the actual conditions. Any changes to the scope of work, and thus potential change orders, should be identified and communicated to TSC.
AutoCAD SHX Text
Tractor Supply Company shall not be responsible for the payment of any work performed or material supplied by the Contractor or any of its sub-contractors, sub-subcontractors and anyone claiming by through or under any of them which is not identified in writing and signed by one of the following Tractor Supply Company personnel: Vice President Real Estate, Vice President of Construction, or a Construction Project Manager. No action, conduct, omission, prior failure, or course of dealing by Tractor Supply Company shall act to waive, modify, change or alter the requirement that all work, whether by contract, change order or change directive, must be in writing and signed by the personnel identified in this provision. Any work performed or material provided by the Contractor, any of its sub-contractors, sub-subcontractors contrary to this provision shall be at its own risk and own expense and Tractor Supply Company shall not be obligated to reimburse or pay the Contractor or any of its sub-contractors, sub-subcontractors for same.
Page 7: COLLIERVILLE, TENNESSEE REVISION DATE: …

RETAIL SALES102

STOCKROOM105

CORRIDOR106

MEN 109110

WOMEN

107

MANAGER'SOFFICE

EMPLOYEE

108LOUNGE

MP1.0

MECHANICAL AND PLUMBING PLANS

MECHANICAL AND PLUMBING FLOOR PLAN

GENERAL PLUMBING SPECIFICATIONS

GENERAL MECHANICAL SPECIFICATIONS

FAN SCHEDULE

MECHANICAL DRAWING NOTES

PLUMBING DRAWINGS NOTES

PLUMBING FIXTURE SCHEDULE

TRACTOR SUPPLY COMPANY

COLLIERVILLETENNESSEE

1163 West Main St.Franklin, TN 37064Tel: 615.730.9111 / Fax: [email protected] #20-133

2934 Sidco Drive

Suite 120

Nashville, TN 37204

OXFORD

ARCHITECTURE

Architecture

Planning

Interior Architecture

AutoCAD SHX Text
EF-2
AutoCAD SHX Text
(EXISTING)
AutoCAD SHX Text
1
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
(EXISTING)
AutoCAD SHX Text
1
AutoCAD SHX Text
MODELNUMBER
AutoCAD SHX Text
TRADENAME
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
MODELNUMBER
AutoCAD SHX Text
TRADENAME
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
MS
AutoCAD SHX Text
2
AutoCAD SHX Text
BS
AutoCAD SHX Text
1
AutoCAD SHX Text
EWC
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
LAV
AutoCAD SHX Text
1
AutoCAD SHX Text
LAV
AutoCAD SHX Text
1
AutoCAD SHX Text
WC
AutoCAD SHX Text
1
AutoCAD SHX Text
UR
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
FURNISH, INSTALL, PROVIDE AND MAKE OPERATIVE ALL EQUIPMENT MATERIALS, SUPERVISION, LABOR AND ANY AND ALL ITEMS NECESSARY FOR THE PROPER INSTALLATION OF THE CORRECTLY FUNCTIONING PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. EQUALS MAY BE SUBSTITUTED ONLY IF PRIOR APPROVAL IS OBTAINED FROM OWNER ORDINANCES, PERMITS AND CODES: THE WORKMANSHIP AND MATERIALS COVERED BY THESE SPECIFICATIONS SHALL CONFORM TO ALL REGULATIONS OF ALL THE AUTHORITIES HAVING JURISDICTION. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, CONNECTION AND INSPECTION FEES AS REQUIRED FOR THE COMPLETE INSTALLATION OF THE PLUMBING SYSTEM. THE LOCATION OF PIPING AND EQUIPMENT, AS SHOWN ON THE DRAWINGS, IS DIAGRAMMATIC AND SCHEMATIC AND IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE HIS OWN WORKING LAYOUT TO ELIMINATE ALL STRUCTURAL AND ARCHITECTURAL CONFLICTS IN THE BUILDING. VERIFY ALL MEASUREMENTS AT THE SITE AND COORDINATE ALL WORK SO THAT IT DOES NOT INTERFERE WITH THE WORK OF THE OTHER TRADES. DOMESTIC WATER PIPES SHALL BE TYPE "L" COPPER ABOVE GROUND / SLAB AND TYPE "K" COPPER BELOW GRADE / SLAB. INSTALL DIELECTRIC UNIONS AT CONNECTION TO DISSIMILAR METALS. ALTERNATIVE WATER PIPING MATERIAL SHALL BE WIRSBO TYPE "A" "PEX" POLYETHYLENE CROSS-BRACED PIPING WITH BRASS / COPPER FITTINGS. SANITARY WASTE AND VENT PIPE SHALL BE CAST IRON WITH NO-HUB FITTINGS OR SCHEDULE 40 PVC. IT IS THE INTENT OF THESE DRAWINGS TO COVER ALL WORK FOR A COMPLETE FIRST CLASS PLUMBING INSTALLATION - ANY EQUIPMENT, TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN THIS CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED BY THE CONSTRUCTION MANAGER) SHALL BE FURNISHED AND INSTALLED BY THE PLUMBING CONTRACTOR AS PART OF HIS TOTAL WORK. JET ALL WASTE LINES AND CAMERA. VIDEO TO BE SENT TO TSC PM. INCLUDE PRICE FOR POTENTIAL REPAIRS.
AutoCAD SHX Text
FURNISH, INSTALL, PROVIDE AND MAKE OPERATIVE ALL EQUIPMENT, MATERIALS, SUPERVISION, LABOR AND ANY AND ALL ITEMS NECESSARY FOR THE PROPER INSTALLATION OF A CORRECTLY FUNCTIONING MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. EQUALS SHALL BE ACCEPTED FOR EQUIPMENT UNLESS OTHERWISE NOTED. ORDINANCES, PERMITS AND CODES: THE WORKMANSHIP AND MATERIALS COVERED BY THESE SPECIFICATIONS SHALL CONFORM TO ALL REGULATIONS OF ALL THE AUTHORITIES HAVING JURISDICTION. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, CONNECTION AND INSPECTION FEES AS REQUIRED FOR THE COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM. THE LOCATION OF DUCTS, PIPE AND EQUIPMENT, AS SHOWN ON THE DRAWINGS, IS DIAGRAMMATIC AND SCHEMATIC AND IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE HIS OWN WORKING LAYOUT TO ELIMINATE ALL STRUCTURAL AND ARCHITECTURAL CONFLICTS IN THE BUILDING. VERIFY ALL MEASUREMENTS AT THE SITE AND COORDINATE ALL WORK SO THAT IT DOES NOT INTERFERE WITH THE WORK OF THE OTHER TRADES. EXHAUST DUCT IS NOT REQUIRED TO BE INSULATED ALL DUCTWORK SHALL BE CONSTRUCTED OF THE BEST BLOOM GALVANIZED SHEETS, FREE FROM BLISTER AND IMPERFECTIONS, AND WITH GAUGES, JOINTS, BRACING AND SUPPORTS IN STRICT ACCORDANCE WITH SMACNA STANDARDS. DUCT SIZES SHOWN ON THE DRAWINGS ARE NET INSIDE CLEAR. SCREWS SHALL BE CADMIUM PLATED. ROUND DUCT RUN-OUTS SHALL BE MIN. 26 GA. SHEET METAL. HANGERS SHALL BE 1" x " GALV. BAND 4' ON CENTER 18" GALV. BAND 4' ON CENTER FLEXIBLE DUCT SHALL BE THERMAFLEX TYPE M-KA OR EQUAL, AND BE U.L. LISTED AND COMPLY WITH NFPA STANDARD NO. 90A. MAXIMUM LENGTH SHALL BE 5 FEET LONG. INSULATION SHALL BE 2" THICK (FLEX. TO BE USED IN CONCEALED LOCATIONS ONLY) HVAC CONTRACTOR SHALL LEAVE HIS WORK IN PERFECT WORKING CONDITION AND SHALL GUARANTEE SAME FOR A PERIOD OF TWELVE (12) MONTHS FROM DATE OF FINAL ACCEPTANCE. IT IS THE INTENT OF THESE DRAWINGS TO COVER ALL WORK FOR A COMPLETE FIRST CLASS MECHANICAL INSTALLATION - ANY EQUIPMENT, TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN THIS CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED BY THE CONSTRUCTION MANAGER) SHALL BE FURNISHED AND INSTALLED BY THE HVAC CONTRACTOR AS PART OF HIS TOTAL WORK.
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
FAN IDENTIFICATION
AutoCAD SHX Text
SERVICE AREA
AutoCAD SHX Text
CFM
AutoCAD SHX Text
FAN TYPE
AutoCAD SHX Text
SONES
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
VOLTAGE/PHASE
AutoCAD SHX Text
ESP
AutoCAD SHX Text
MODEL NUMBER
AutoCAD SHX Text
ACCESSORIES:
AutoCAD SHX Text
ACCESSORIES REQUIRED
AutoCAD SHX Text
MOTOR POWER
AutoCAD SHX Text
A: BACKDRAFT DAMPER
AutoCAD SHX Text
B: VARIABLE SPEED CONTROLLER
AutoCAD SHX Text
EF-1 & 2 (ALTERNATE)
AutoCAD SHX Text
REST ROOM
AutoCAD SHX Text
EXISTING CEILING MOUNTED EXHAUST FAN AND ALL ASSOCIATED DUCTWORK TO REMAIN. CONTRACTOR SHALL FIELD VERIFY EXISTING EXHAUST FAN IS IN GOOD WORKING CONDITION. CONTRACTOR SHALL PROVIDE ALTERNATE BID TO REPLACE EXHAUST FAN PER FAN SCHEDULE. FURNISH AND INSTALL NEW DUCTWORK, CONTROL WIRING, ETC. FOR A COMPLETE AND OPERABLE SYSTEM.
AutoCAD SHX Text
COOK
AutoCAD SHX Text
150
AutoCAD SHX Text
CABINET CENT.
AutoCAD SHX Text
3.5
AutoCAD SHX Text
15 LBS
AutoCAD SHX Text
120/1%%C
AutoCAD SHX Text
.35
AutoCAD SHX Text
GC-168
AutoCAD SHX Text
A,B
AutoCAD SHX Text
60 WATTS
AutoCAD SHX Text
1
AutoCAD SHX Text
EXISTING PLUMBING FIXTURE TO BE REPLACED PER "PLUMBING FIXTURE SCHEDULE". USE EXISTING UTILITIES WITHIN WALLS AND FLOOR TO RE-CONNECT AT MODIFIED LOCATIONS. CONTRACTOR TO FIELD VERIFY EXACT LOCATIONS OF EXISTING UTILITY CONNECTIONS BEFORE CONSTRUCTION. CAPACITY TEST EXISTING MOP SINK. BID AS ALTERNATE IF BASIN OR FAUCET ARE FOUND LEAKING.
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
CW
AutoCAD SHX Text
UTILITIES
AutoCAD SHX Text
HW
AutoCAD SHX Text
DR
AutoCAD SHX Text
VENT
AutoCAD SHX Text
MARK
AutoCAD SHX Text
BS
AutoCAD SHX Text
12"
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
1 "14"
AutoCAD SHX Text
12"
AutoCAD SHX Text
BREAKROOM SINK: (SINGLE BOWL, S.S., GOOSENECK): PROVIDED BY TRACTOR SUPPLY COMPANY & INSTALLED BY CONTRACTOR.
AutoCAD SHX Text
LAVATORY (ACCESSIBLE, WALL HUNG, MOTION ACTIVATED): KOHLER KINGSTON WALL-MOUNT K-2005, VITREOUS CHINA LAVATORY WITH A ZURN AQUASENSE BATTERY POWERED Z6915-XL FAUCET, POLISHED CHROME FINISH, KOHLER K-23726 DRAIN, KOHLER K-8998 P-TRAP AND KOHLER K-23725 CAST IRON CLEANER. MOUNT FIXTURE WITH FLOOD RIM 34" AFF. FURNISH AND INSTALL WITH ZURN MODEL ZW3870XLT THERMAL MIXING VALVE FOR MAX. 110°F HOT WATER.
AutoCAD SHX Text
LAV
AutoCAD SHX Text
12"
AutoCAD SHX Text
1 "14"
AutoCAD SHX Text
1 "14"
AutoCAD SHX Text
12"
AutoCAD SHX Text
WC
AutoCAD SHX Text
12"
AutoCAD SHX Text
4"
AutoCAD SHX Text
X
AutoCAD SHX Text
2"
AutoCAD SHX Text
WATER CLOSET (ACCESSIBLE, FLOOR MTD., PRESSURE ASSISTED FLUSH TANK, MOTION ACTIVATED): KOHLER HIGHLINE K-3519, 12" ROUGH-IN, 1.0 GPF, WITH SLOAN FLUSHMATE PRESSURE ASSIST, LOW CONSUMPTION, VITREOUS CHINA, 17-1/8" HIGH, ELONGATED BOWL FLUSH TANK WATER CLOSET WITH LEFT HAND TRIP LEVER. PROVIDE KOHLER K-5588 ELONGATED TOILET SEAT, K-5420 BOLT CAPS. FOR RIGHT HAND TRIP LEVER PROVIDE WITH ALTERNATE TANK CONFIGURATION MODEL K-3519-RH. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING CORRECT TANK SELECTION WITH LATEST ARCHITECTURAL DRAWINGS TO ACCOMMODATE ADA ACCESSIBILITY PRIOR TO ORDERING. PROVIDE WITH INTELLI-FLUSH K-100101 WALL SENSOR, POWERED BY FOUR(4) AA BATTERIES, CHROME FINISH.
AutoCAD SHX Text
MOP SINK : MUSTEE MODEL 63M 24"x24" FIBERGLASS MOP SERVICE BASIN. COMPLETE WITH MODEL 63.401 EXTRUDED BUMPER GUARD, CHICAGO MODEL 897-RCF CHROME PLATED SPOUT WITH VACUUM BREAKER, " HOSE THREAD OUTLET, PAIL HOOK. WALL 34" HOSE THREAD OUTLET, PAIL HOOK. WALL SUPPORT, INTEGRAL STOPS, MODEL 369 2 " METAL LEVER HANDLES AND 36" LENGTH OF THREADED HOSE.12" METAL LEVER HANDLES AND 36" LENGTH OF THREADED HOSE.
AutoCAD SHX Text
MS
AutoCAD SHX Text
12"
AutoCAD SHX Text
3"
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
EWC
AutoCAD SHX Text
12"
AutoCAD SHX Text
1 "14"
AutoCAD SHX Text
1 "14"
AutoCAD SHX Text
X
AutoCAD SHX Text
Job Number:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Sheet Number:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
Revisions:
AutoCAD SHX Text
2000.064
AutoCAD SHX Text
11.23.2020
AutoCAD SHX Text
This drawing and the design shown is the property of the architect. The reproduction, copying or use of this drawing without their written consent is prohibited and any infringement will be subject to legal action.
AutoCAD SHX Text
All measurements and items portrayed on this sheet are deemed to be accurate by architect, however all bidding General Contractors should field verify the actual conditions. Any changes to the scope of work, and thus potential change orders, should be identified and communicated to TSC.
AutoCAD SHX Text
Tractor Supply Company shall not be responsible for the payment of any work performed or material supplied by the Contractor or any of its sub-contractors, sub-subcontractors and anyone claiming by through or under any of them which is not identified in writing and signed by one of the following Tractor Supply Company personnel: Vice President Real Estate, Vice President of Construction, or a Construction Project Manager. No action, conduct, omission, prior failure, or course of dealing by Tractor Supply Company shall act to waive, modify, change or alter the requirement that all work, whether by contract, change order or change directive, must be in writing and signed by the personnel identified in this provision. Any work performed or material provided by the Contractor, any of its sub-contractors, sub-subcontractors contrary to this provision shall be at its own risk and own expense and Tractor Supply Company shall not be obligated to reimburse or pay the Contractor or any of its sub-contractors, sub-subcontractors for same.
AutoCAD SHX Text
UR
AutoCAD SHX Text
34"
AutoCAD SHX Text
2"
AutoCAD SHX Text
X
AutoCAD SHX Text
URINAL (WALL HUNG, MOTION ACTIVATED): KOHLER MODEL K-2590, BARDON, WATERSENSE, VITREOUS CHINA URINAL WITH A " REAR SPUD AND AN INTEGRAL AA 12" REAR SPUD AND AN INTEGRAL AA BATTERY OPERATED TOUCHLESS ELECTRONIC FLUSH VALVE (0.5 GFP). PROVIDE WITH TANK COVER, TANK COVER LOCKS, AND WALL MOUNTING BRACKETS.
AutoCAD SHX Text
1 "12"
AutoCAD SHX Text
ELECTRIC WATER COOLER (ACCESSIBLE, DUAL-HEIGHT, MOTION ACTIVATED): OASIS MODEL PG8ACSLTT WITH INFRARED SENSOR CONTROLS AND WALL MOUNTING BRACKET. 8 GPH, 115/1/60. MOUNT HIGH UNIT AT 42" MAXIMUM FROM FLOOR TO SPOUT OUTLET AND LOW UNIT AT 36" MAXIMUM FROM FLOOR TO SPOUT OUTLET. PROVIDE MCGUIRE 8872 P-TRAP AND MCGUIRE 165-CC SUPPLY WITH STOP. COORDINATE WITH ELECTRICAL CONTRACTOR TO LOCATE RECEPTACLE BEHIND WATER COOLER CABINET.
Page 8: COLLIERVILLE, TENNESSEE REVISION DATE: …

E1.0GENERAL ELECTRICAL PLAN

PARSONSENGINEERING.COMPARSONSENGINEERING.COM

TRACTOR SUPPLY COMPANY

COLLIERVILLETENNESSEE

RETAIL SALES102

STOCKROOM105

CORRIDOR106

MEN 109110

WOMEN

107

MANAGER'SOFFICE

EMPLOYEE

108LOUNGE

VESTIBULE101

DRESSING

104ROOM

Page 9: COLLIERVILLE, TENNESSEE REVISION DATE: …

E2.0ELECTRICAL NOTES AND DETAILS

PARSONSENGINEERING.COMPARSONSENGINEERING.COM

TRACTOR SUPPLY COMPANY

COLLIERVILLETENNESSEE