Diagnostic Troubleshoot Code BRK Codes Description [Data Link] SPN, CID, or PID - FMI SIS Links 38-00 [J1939/ATA] Second Fuel Level - Data Valid but above Normal Operating Range (most severe) - External Tank High Fuel Level Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM 38-01 [J1939/ATA] Second Fuel Level - External Tank Low Fuel Level Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM 38-03 [J1939/ATA] Second Fuel Level - External Tank Fuel Level Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM 38-04 [J1939/ATA] Second Fuel Level - External Tank Fuel Level Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM 38-15 [J1939/ATA] Second Fuel Level - Data Valid but above Normal Operating Range (least severe) - External Tank High Fuel Level Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM 38-17 [J1939/ATA] Second Fuel Level - Data Valid But Below Normal Operating Range (least severe) - External Tank Low Fuel Level Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM 82-00 [J1939] Engine Air Start Pressure [CDL] Air Start Pressure Sensor [ATA] Cylinder #3 Compression Brake - Data Valid but above Normal Operating Range (most severe) - High Starting Air Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

Codigos Emcp II Brk

Embed Size (px)

Citation preview

Page 1: Codigos Emcp II Brk

Diagnostic Troubleshoot Code BRK

Codes Description

[Data Link] SPN, CID, or PID - FMI SIS Links

38-00

[J1939/ATA] Second Fuel Level - Data Valid but above Normal Operating Range (most severe)

- External Tank High Fuel Level Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

38-01 [J1939/ATA] Second Fuel Level

- External Tank Low Fuel Level Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

38-03 [J1939/ATA] Second Fuel Level

- External Tank Fuel Level Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

38-04 [J1939/ATA] Second Fuel Level

- External Tank Fuel Level Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

38-15

[J1939/ATA] Second Fuel Level - Data Valid but above Normal Operating Range (least severe)

- External Tank High Fuel Level Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

38-17

[J1939/ATA] Second Fuel Level - Data Valid But Below Normal Operating Range (least severe)

- External Tank Low Fuel Level Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

82-00

[J1939] Engine Air Start Pressure [CDL] Air Start Pressure Sensor [ATA] Cylinder #3 Compression Brake - Data Valid but above Normal Operating Range (most severe)

- High Starting Air Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

Page 2: Codigos Emcp II Brk

82-01

[J1939] Engine Air Start Pressure [CDL] Air Start Pressure Sensor [ATA] Cylinder #3 Compression Brake

- Low Starting Air Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

82-03

[J1939] Engine Air Start Pressure [CDL] Air Start Pressure Sensor [ATA] Cylinder #3 Compression Brake

- Starting Air Pressure Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

82-04

[J1939] Engine Air Start Pressure [CDL] Air Start Pressure Sensor [ATA] Cylinder #3 Compression Brake

- Starting Air Pressure Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

82-15

[J1939] Engine Air Start Pressure [CDL] Air Start Pressure Sensor [ATA] Cylinder #3 Compression Brake - Data Valid but above Normal Operating Range (least severe)

- High Starting Air Pressure Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

82-17

[J1939] Engine Air Start Pressure [CDL] Air Start Pressure Sensor [ATA] Cylinder #3 Compression Brake - Data Valid But Below Normal Operating Range (least severe)

- Low Starting Air Pressure Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

95-00

[J1939] Engine Fuel Filter Differential Pressure [CDL] Fuel Filter Differential Pressure Sensor [ATA] Fuel Filter Restriction - Data Valid but above Normal Operating Range (most severe)

- High Fuel Filter Differential Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

95-01

[J1939] Engine Fuel Filter Differential Pressure [CDL] Fuel Filter Differential Pressure Sensor [ATA] Fuel Filter Restriction

- Low Fuel Filter Differential Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

95-03

[J1939] Engine Fuel Filter Differential Pressure [CDL] Fuel Filter Differential Pressure Sensor

- Fuel Filter Differential Pressure Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL

Page 3: Codigos Emcp II Brk

[ATA] Fuel Filter Restriction

- 7566 - WIRING DIAGRAM

95-04

[J1939] Engine Fuel Filter Differential Pressure [CDL] Fuel Filter Differential Pressure Sensor [ATA] Fuel Filter Restriction

- Fuel Filter Differential Pressure Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

95-15

[J1939] Engine Fuel Filter Differential Pressure [CDL] Fuel Filter Differential Pressure Sensor [ATA] Fuel Filter Restriction - Data Valid but above Normal Operating Range (least severe)

- High Fuel Filter Differential Pressure Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

95-17

[J1939] Engine Fuel Filter Differential Pressure [CDL] Fuel Filter Differential Pressure Sensor [ATA] Fuel Filter Restriction - Data Valid But Below Normal Operating Range (least severe)

- Low Fuel Filter Differential Pressure Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

96-00

[J1939] Fuel Level [CDL] Fuel Level Sensor [ATA] Fuel Level - Data Valid but above Normal Operating Range (most severe)

- High Fuel Level Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

96-01

[J1939] Fuel Level [CDL] Fuel Level Sensor [ATA] Fuel Level

- Low Fuel Level Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

96-03

[J1939] Fuel Level [CDL] Fuel Level Sensor [ATA] Fuel Level

- Fuel Level Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

96-04

[J1939] Fuel Level [CDL] Fuel Level Sensor [ATA] Fuel Level

- Fuel Level Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

96-15 [J1939] Fuel Level [CDL] Fuel Level Sensor

- High Fuel Level Warning - Digital Input Circuit Fault - Analog Input Circuit Fault

Page 4: Codigos Emcp II Brk

[ATA] Fuel Level - Data Valid but above Normal Operating Range (least severe)

- 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

96-17

[J1939] Fuel Level [CDL] Fuel Level Sensor [ATA] Fuel Level - Data Valid But Below Normal Operating Range (least severe)

- Low Fuel Level Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

98-00

[J1939] Engine Oil Level [CDL] Engine Oil Level Sensor [ATA] Engine Oil Level - Data Valid but above Normal Operating Range (most severe)

- High Engine Oil Level Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

98-01

[J1939] Engine Oil Level [CDL] Engine Oil Level Sensor [ATA] Engine Oil Level

- Low Engine Oil Level Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

98-03

[J1939] Engine Oil Level [CDL] Engine Oil Level Sensor [ATA] Engine Oil Level

- Engine Oil Level Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

98-04

[J1939] Engine Oil Level [CDL] Engine Oil Level Sensor [ATA] Engine Oil Level

- Engine Oil Level Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

98-15

[J1939] Engine Oil Level [CDL] Engine Oil Level Sensor [ATA] Engine Oil Level - Data Valid but above Normal Operating Range (least severe)

- High Engine Oil Level Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

98-17

[J1939] Engine Oil Level [CDL] Engine Oil Level Sensor [ATA] Engine Oil Level - Data Valid But Below Normal Operating Range (least severe)

- Low Engine Oil Level Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

Page 5: Codigos Emcp II Brk

99-00

[J1939] Engine Oil Filter Differential Pressure [CDL] Engine Oil Filter Differential Pressure Sensor [ATA] Engine Oil Filter Restriction - Data Valid but above Normal Operating Range (most severe)

- High Oil Filter Differential Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

99-01

[J1939] Engine Oil Filter Differential Pressure [CDL] Engine Oil Filter Differential Pressure Sensor [ATA] Engine Oil Filter Restriction

- Low Oil Filter Differential Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

99-03

[J1939] Engine Oil Filter Differential Pressure [CDL] Engine Oil Filter Differential Pressure Sensor [ATA] Engine Oil Filter Restriction

- Oil Filter Differential Pressure Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

99-04

[J1939] Engine Oil Filter Differential Pressure [CDL] Engine Oil Filter Differential Pressure Sensor [ATA] Engine Oil Filter Restriction

- Oil Filter Differential Pressure Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

99-15

[J1939] Engine Oil Filter Differential Pressure [CDL] Engine Oil Filter Differential Pressure Sensor [ATA] Engine Oil Filter Restriction - Data Valid but above Normal Operating Range (least severe)

- High Oil Filter Differential Pressure Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

99-17

[J1939] Engine Oil Filter Differential Pressure [CDL] Engine Oil Filter Differential Pressure Sensor [ATA] Engine Oil Filter Restriction - Data Valid But Below Normal Operating Range (least severe)

- Low Oil Filter Differential Pressure Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

100-01

[J1939] Engine Oil Pressure [CDL] Engine Oil Pressure Sensor [ATA] Oil Pressure

- Low Engine Oil Pressure Shutdown - Data Link Circuit Fault - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL

Page 6: Codigos Emcp II Brk

- 7566 - WIRING DIAGRAM

100-03

[J1939] Engine Oil Pressure [CDL] Engine Oil Pressure Sensor [ATA] Oil Pressure

- Engine Oil Pressure Sensor Short High

100-04

[J1939] Engine Oil Pressure [CDL] Engine Oil Pressure Sensor [ATA] Oil Pressure

- Engine Oil Pressure Sensor Short Low

100-17

[J1939] Engine Oil Pressure [CDL] Engine Oil Pressure Sensor [ATA] Oil Pressure - Data Valid But Below Normal Operating Range (least severe)

- Low Engine Oil Pressure Warning - Data Link Circuit Fault - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

107-00

[J1939] Engine Air Filter 1 Differential Pressure - Data Valid but above Normal Operating Range (most severe)

- High Air Filter Differential Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

107-01 [J1939] Engine Air Filter 1 Differential Pressure

- Low Air Filter Differential Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

107-03 [J1939] Engine Air Filter 1 Differential Pressure

- Air Filter Differential Pressure Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

107-04 [J1939] Engine Air Filter 1 Differential Pressure

- Air Filter Differential Pressure Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

107-15

[J1939] Engine Air Filter 1 Differential Pressure - Data Valid but above Normal Operating Range (least severe)

- High Air Filter Differential Pressure Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

107-17

[J1939] Engine Air Filter 1 Differential Pressure - Data Valid But Below Normal

- Low Air Filter Differential Pressure Warning - Digital Input Circuit Fault - Analog Input Circuit Fault

Page 7: Codigos Emcp II Brk

Operating Range (least severe) - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

110-00

[J1939] Engine Coolant Temperature [CDL] Engine Coolant Temperature Sensor [ATA] Coolant Temperature - Data Valid but above Normal Operating Range (most severe)

- High Engine Coolant Temperature Shutdown - Data Link Circuit Fault - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

110-03

[J1939] Engine Coolant Temperature [CDL] Engine Coolant Temperature Sensor [ATA] Coolant Temperature

- Engine Coolant Temperature Sensor Short High

110-04

[J1939] Engine Coolant Temperature [CDL] Engine Coolant Temperature Sensor [ATA] Coolant Temperature

- Engine Coolant Temperature Sensor Short Low

110-15

[J1939] Engine Coolant Temperature [CDL] Engine Coolant Temperature Sensor [ATA] Coolant Temperature - Data Valid but above Normal Operating Range (least severe)

- High Engine Coolant Temperature Warning - Data Link Circuit Fault - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

110-17

[J1939] Engine Coolant Temperature [CDL] Engine Coolant Temperature Sensor [ATA] Coolant Temperature - Data Valid But Below Normal Operating Range (least severe)

- Low Engine Coolant Temperature Warning - Data Link Circuit Fault - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

111-00

[J1939] Engine Coolant Level [CDL] Engine Coolant Level Sensor [ATA] Coolant Level - Data Valid but above Normal Operating Range (most severe)

- High Engine Coolant Level Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

111-01

[J1939] Engine Coolant Level [CDL] Engine Coolant Level Sensor [ATA] Coolant Level

- Low Engine Coolant Level Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

Page 8: Codigos Emcp II Brk

111-03

[J1939] Engine Coolant Level [CDL] Engine Coolant Level Sensor [ATA] Coolant Level

- Engine Coolant Level Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

111-04

[J1939] Engine Coolant Level [CDL] Engine Coolant Level Sensor [ATA] Coolant Level

- Engine Coolant Level Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

111-15

[J1939] Engine Coolant Level [CDL] Engine Coolant Level Sensor [ATA] Coolant Level - Data Valid but above Normal Operating Range (least severe)

- High Engine Coolant Level Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

111-17

[J1939] Engine Coolant Level [CDL] Engine Coolant Level Sensor [ATA] Coolant Level - Data Valid But Below Normal Operating Range (least severe)

- Low Engine Coolant Level Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

137-00

[J1939] Auxiliary Gage Pressure Reading 1 [CDL] Left Motor Pilot Pressure Sensor [ATA] Intake Valve Actuation System Oil Pressure Solenoid - Data Valid but above Normal Operating Range (most severe)

- High Fire Extinguisher Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

137-01

[J1939] Auxiliary Gage Pressure Reading 1 [CDL] Left Motor Pilot Pressure Sensor [ATA] Intake Valve Actuation System Oil Pressure Solenoid

- Low Fire Extinguisher Pressure Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

137-03

[J1939] Auxiliary Gage Pressure Reading 1 [CDL] Left Motor Pilot Pressure Sensor [ATA] Intake Valve Actuation System Oil Pressure Solenoid

- Fire Extinguisher Pressure Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

137-04

[J1939] Auxiliary Gage Pressure Reading 1 [CDL] Left Motor Pilot Pressure Sensor

- Fire Extinguisher Pressure Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL

Page 9: Codigos Emcp II Brk

[ATA] Intake Valve Actuation System Oil Pressure Solenoid

- 7566 - WIRING DIAGRAM

137-15

[J1939] Auxiliary Gage Pressure Reading 1 [CDL] Left Motor Pilot Pressure Sensor [ATA] Intake Valve Actuation System Oil Pressure Solenoid - Data Valid but above Normal Operating Range (least severe)

- High Fire Extinguisher Pressure Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

137-17

[J1939] Auxiliary Gage Pressure Reading 1 [CDL] Left Motor Pilot Pressure Sensor [ATA] Intake Valve Actuation System Oil Pressure Solenoid - Data Valid But Below Normal Operating Range (least severe)

- Low Fire Extinguisher Pressure Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

167-17

[J1939] Charging System Potential [CDL] Alternator Charging Voltage Sensor - Data Valid But Below Normal Operating Range (least severe)

- Low Battery Charging System Voltage Warning - Charging System - 1401 - BATTERY - 1405 - ALTERNATOR - 7566 - WIRING DIAGRAM

168-00

[J1939] Battery Potential [CDL] Electrical System Voltage [ATA] ECM Battery Power - Data Valid but above Normal Operating Range (most severe)

- High Battery Voltage Shutdown - Charging System - 1401 - BATTERY - 1405 - ALTERNATOR - 7566 - WIRING DIAGRAM

168-15

[J1939] Battery Potential [CDL] Electrical System Voltage [ATA] ECM Battery Power - Data Valid but above Normal Operating Range (least severe)

- High Battery Voltage Warning - Charging System - 1401 - BATTERY - 1405 - ALTERNATOR - 7566 - WIRING DIAGRAM

168-17

[J1939] Battery Potential [CDL] Electrical System Voltage [ATA] ECM Battery Power - Data Valid But Below Normal Operating Range (least severe)

- Low Battery Voltage Warning - Charging System - 1401 - BATTERY - 1405 - ALTERNATOR - 7566 - WIRING DIAGRAM

171-00

[J1939] Ambient Air Temperature [CDL] Ambient Air Temperature Sensor

- High Ambient Air Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault

Page 10: Codigos Emcp II Brk

[ATA] Loss of Ambient Air Temperature Data - Data Valid but above Normal Operating Range (most severe)

- 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

171-01

[J1939] Ambient Air Temperature [CDL] Ambient Air Temperature Sensor [ATA] Loss of Ambient Air Temperature Data

- Low Ambient Air Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

171-03

[J1939] Ambient Air Temperature [CDL] Ambient Air Temperature Sensor [ATA] Loss of Ambient Air Temperature Data

- Ambient Air Temperature Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

171-04

[J1939] Ambient Air Temperature [CDL] Ambient Air Temperature Sensor [ATA] Loss of Ambient Air Temperature Data

- Ambient Air Temperature Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

171-15

[J1939] Ambient Air Temperature [CDL] Ambient Air Temperature Sensor [ATA] Loss of Ambient Air Temperature Data - Data Valid but above Normal Operating Range (least severe)

- High Ambient Air Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

171-17

[J1939] Ambient Air Temperature [CDL] Ambient Air Temperature Sensor [ATA] Loss of Ambient Air Temperature Data - Data Valid But Below Normal Operating Range (least severe)

- Low Ambient Air Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

173-00

[J1939] Engine Exhaust Gas Temperature [ATA] Exhaust Gas Temperature - Data Valid but above Normal Operating Range (most severe)

- High Exhaust Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

173-01

[J1939] Engine Exhaust Gas Temperature [ATA] Exhaust Gas Temperature

- Low Exhaust Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

Page 11: Codigos Emcp II Brk

173-03

[J1939] Engine Exhaust Gas Temperature [ATA] Exhaust Gas Temperature

- Exhaust Temperature Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

173-04

[J1939] Engine Exhaust Gas Temperature [ATA] Exhaust Gas Temperature

- Exhaust Temperature Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

173-08

[J1939] Engine Exhaust Gas Temperature [ATA] Exhaust Gas Temperature

- Exhaust Temperature Signal Abnormal

173-15

[J1939] Engine Exhaust Gas Temperature [ATA] Exhaust Gas Temperature - Data Valid but above Normal Operating Range (least severe)

- High Exhaust Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

173-17

[J1939] Engine Exhaust Gas Temperature [ATA] Exhaust Gas Temperature - Data Valid But Below Normal Operating Range (least severe)

- Low Exhaust Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

175-00

[J1939] Engine Oil Temperature 1 [CDL] Engine Oil Temperature Sensor [ATA] Engine Oil Temperature - Data Valid but above Normal Operating Range (most severe)

- High Engine Oil Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

175-01

[J1939] Engine Oil Temperature 1 [CDL] Engine Oil Temperature Sensor [ATA] Engine Oil Temperature

- Low Engine Oil Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

175-03

[J1939] Engine Oil Temperature 1 [CDL] Engine Oil Temperature Sensor [ATA] Engine Oil Temperature

- Engine Oil Temperature Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

175-04

[J1939] Engine Oil Temperature 1 [CDL] Engine Oil Temperature Sensor [ATA] Engine Oil Temperature

- Engine Oil Temperature Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL

Page 12: Codigos Emcp II Brk

- 7566 - WIRING DIAGRAM

175-15

[J1939] Engine Oil Temperature 1 [CDL] Engine Oil Temperature Sensor [ATA] Engine Oil Temperature - Data Valid but above Normal Operating Range (least severe)

- High Engine Oil Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

175-17

[J1939] Engine Oil Temperature 1 [CDL] Engine Oil Temperature Sensor [ATA] Engine Oil Temperature - Data Valid But Below Normal Operating Range (least severe)

- Low Engine Oil Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

190-00

[J1939] Engine Speed [CDL] Engine Speed Sensor [ATA] Primary Engine Speed - Data Valid but above Normal Operating Range (most severe)

- Engine Over Speed Shutdown - Engine Overspeed Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

190-01

[J1939] Engine Speed [CDL] Engine Speed Sensor [ATA] Primary Engine Speed

- Engine Under Speed Shutdown - Engine Underspeed Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

190-02

[J1939] Engine Speed [CDL] Engine Speed Sensor [ATA] Primary Engine Speed

- Engine Speed Sensor Erratic or Not Present - Engine Speed Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

190-05

[J1939] Engine Speed [CDL] Engine Speed Sensor [ATA] Primary Engine Speed

- Engine Speed Sensor Open - Engine Speed Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

190-17

[J1939] Engine Speed [CDL] Engine Speed Sensor [ATA] Primary Engine Speed - Data Valid But Below Normal Operating Range (least severe)

- Engine Under Speed Warning - Engine Underspeed Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

234-31 [J1939] Software Identification - Not Available Or Condition Exists

- Software Version Mismatch

625-11 [J1939] Proprietary Data Link - Failure Mode Not Identifiable

- SCADA Data Link Fault - Data Link Circuit Fault - 4490 - ELECTRONIC

Page 13: Codigos Emcp II Brk

MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

639-11 [J1939] J1939 Network #1 - Failure Mode Not Identifiable

- Primary Data Link Fault - Data Link Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

701-00

[J1939] Auxiliary I [CDL] Transmission Output Speed Sensor - Data Valid but above Normal Operating Range (most severe)

- Custom Event #1 High Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

701-01

[J1939] Auxiliary I [CDL] Transmission Output Speed Sensor

- Custom Event #1 Low Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

701-15

[J1939] Auxiliary I [CDL] Transmission Output Speed Sensor - Data Valid but above Normal Operating Range (least severe)

- Custom Event #1 High Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

701-17

[J1939] Auxiliary I [CDL] Transmission Output Speed Sensor - Data Valid But Below Normal Operating Range (least severe)

- Custom Event #1 Low Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

701-31

[J1939] Auxiliary I [CDL] Transmission Output Speed Sensor - Not Available Or Condition Exists

- Custom Event #1 Status - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

702-00

[J1939] Auxiliary I [CDL] Transmission Gear Lever Selector Sensor (Switch) - Data Valid but above Normal Operating Range (most severe)

- Custom Event #2 High Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

702-01

[J1939] Auxiliary I [CDL] Transmission Gear Lever Selector Sensor (Switch)

- Custom Event #2 Low Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

702-15 [J1939] Auxiliary I [CDL] Transmission Gear Lever

- Custom Event #2 High Warning - Digital Input Circuit Fault

Page 14: Codigos Emcp II Brk

Selector Sensor (Switch) - Data Valid but above Normal Operating Range (least severe)

- 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

702-17

[J1939] Auxiliary I [CDL] Transmission Gear Lever Selector Sensor (Switch) - Data Valid But Below Normal Operating Range (least severe)

- Custom Event #2 Low Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

702-31

[J1939] Auxiliary I [CDL] Transmission Gear Lever Selector Sensor (Switch) - Not Available Or Condition Exists

- Custom Event #2 Status - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

703-00

[J1939] Auxiliary I [CDL] Trailer Door Position Sensor - Data Valid but above Normal Operating Range (most severe)

- Custom Event #3 High Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

703-01 [J1939] Auxiliary I [CDL] Trailer Door Position Sensor

- Custom Event #3 Low Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

703-15

[J1939] Auxiliary I [CDL] Trailer Door Position Sensor - Data Valid but above Normal Operating Range (least severe)

- Custom Event #3 High Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

703-17

[J1939] Auxiliary I [CDL] Trailer Door Position Sensor - Data Valid But Below Normal Operating Range (least severe)

- Custom Event #3 Low Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

703-31

[J1939] Auxiliary I [CDL] Trailer Door Position Sensor - Not Available Or Condition Exists

- Custom Event #3 Status - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

704-00

[J1939] Auxiliary I [CDL] Service Brake Pressure Switch - Data Valid but above Normal Operating Range (most severe)

- Custom Event #4 High Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

704-01 [J1939] Auxiliary I [CDL] Service Brake Pressure Switch

- Custom Event #4 Low Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC

Page 15: Codigos Emcp II Brk

MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

704-15

[J1939] Auxiliary I [CDL] Service Brake Pressure Switch - Data Valid but above Normal Operating Range (least severe)

- Custom Event #4 High Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

704-17

[J1939] Auxiliary I [CDL] Service Brake Pressure Switch - Data Valid But Below Normal Operating Range (least severe)

- Custom Event #4 Low Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

704-31

[J1939] Auxiliary I [CDL] Service Brake Pressure Switch - Not Available Or Condition Exists

- Custom Event #4 Status - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

705-00

[J1939] Auxiliary I [CDL] Body Raise Sensor (Switch) - Data Valid but above Normal Operating Range (most severe)

- Custom Event #5 High Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

705-01 [J1939] Auxiliary I [CDL] Body Raise Sensor (Switch)

- Custom Event #5 Low Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

705-15

[J1939] Auxiliary I [CDL] Body Raise Sensor (Switch) - Data Valid but above Normal Operating Range (least severe)

- Custom Event #5 High Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

705-17

[J1939] Auxiliary I [CDL] Body Raise Sensor (Switch) - Data Valid But Below Normal Operating Range (least severe)

- Custom Event #5 Low Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

705-31

[J1939] Auxiliary I [CDL] Body Raise Sensor (Switch) - Not Available Or Condition Exists

- Custom Event #5 Status - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

706-00

[J1939] Auxiliary I [CDL] Body Up Sensor - Data Valid but above Normal Operating Range (most severe)

- Custom Event #6 High Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

706-01 [J1939] Auxiliary I - Custom Event #6 Low

Page 16: Codigos Emcp II Brk

[CDL] Body Up Sensor

Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

706-15

[J1939] Auxiliary I [CDL] Body Up Sensor - Data Valid but above Normal Operating Range (least severe)

- Custom Event #6 High Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

706-17

[J1939] Auxiliary I [CDL] Body Up Sensor - Data Valid But Below Normal Operating Range (least severe)

- Custom Event #6 Low Warning - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

706-31

[J1939] Auxiliary I [CDL] Body Up Sensor - Not Available Or Condition Exists

- Custom Event #6 Status - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

707-00

[J1939] Auxiliary I [CDL] Transmission Gear Actuator Up Solenoid - Data Valid but above Normal Operating Range (most severe)

- Custom Event #7 High Shutdown - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

707-01

[J1939] Auxiliary I [CDL] Transmission Gear Actuator Up Solenoid

- Custom Event #7 Low Shutdown - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

707-15

[J1939] Auxiliary I [CDL] Transmission Gear Actuator Up Solenoid - Data Valid but above Normal Operating Range (least severe)

- Custom Event #7 High Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

707-17

[J1939] Auxiliary I [CDL] Transmission Gear Actuator Up Solenoid - Data Valid But Below Normal Operating Range (least severe)

- Custom Event #7 Low Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

707-31

[J1939] Auxiliary I [CDL] Transmission Gear Actuator Up Solenoid - Not Available Or Condition Exists

- Custom Event #7 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

708-00 [J1939] Auxiliary I

- Custom Event #8 High Shutdown

Page 17: Codigos Emcp II Brk

[CDL] Transmission Gear Actuator Down Solenoid - Data Valid but above Normal Operating Range (most severe)

- 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

708-01

[J1939] Auxiliary I [CDL] Transmission Gear Actuator Down Solenoid

- Custom Event #8 Low Shutdown - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

708-15

[J1939] Auxiliary I [CDL] Transmission Gear Actuator Down Solenoid - Data Valid but above Normal Operating Range (least severe)

- Custom Event #8 High Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

708-17

[J1939] Auxiliary I [CDL] Transmission Gear Actuator Down Solenoid - Data Valid But Below Normal Operating Range (least severe)

- Custom Event #8 Low Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

708-31

[J1939] Auxiliary I [CDL] Transmission Gear Actuator Down Solenoid - Not Available Or Condition Exists

- Custom Event #8 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

709-31

[J1939] Auxiliary I [CDL] Transmission Lockup Clutch Solenoid - Not Available Or Condition Exists

- Custom Event #9 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

710-31

[J1939] Auxiliary I [CDL] ARC Supply Solenoid - Not Available Or Condition Exists

- Custom Event #10 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

711-31

[J1939] Auxiliary I [CDL] ARC Control Solenoid - Not Available Or Condition Exists

- Custom Event #11 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

712-31

[J1939] Auxiliary I [CDL] Retarder Control Lamp - Not Available Or Condition Exists

- Custom Event #12 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

713-31

[J1939] Auxiliary I [CDL] Auto Retarder On - Not Available Or Condition Exists

- Custom Event #13 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

Page 18: Codigos Emcp II Brk

714-31

[J1939] Auxiliary I [CDL] Auto Retarder Pressure Switch - Not Available Or Condition Exists

- Custom Event #14 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

715-31

[J1939] Auxiliary I [CDL] Retarder Pressure Switch - Not Available Or Condition Exists

- Custom Event #15 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

716-31

[J1939] Auxiliary I [CDL] Watt Transducer - Not Available Or Condition Exists

- Custom Event #16 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

924-03

[J1939] Auxiliary Output #1 [CDL] Burner Control Electronic Control Module

- Digital Output #1 Short High - Digital Output Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

925-03 [J1939] Auxiliary Output #2 [CDL] Burner Control Diagnostic Lamp

- Digital Output #2 Short High - Digital Output Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

970-31

[J1939] Engine Auxiliary Engine Shutdown Switch [CDL] Center - Not Available Or Condition Exists

- Emergency Stop Shutdown - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

1122-00

[J1939] Engine Alternator Bearing 1 Temperature [CDL] Rear System High Pressure Solenoid - Data Valid but above Normal Operating Range (most severe)

- High Generator Bearing #1 Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

1122-01

[J1939] Engine Alternator Bearing 1 Temperature [CDL] Rear System High Pressure Solenoid

- Low Generator Rear Bearing Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

1122-03

[J1939] Engine Alternator Bearing 1 Temperature [CDL] Rear System High Pressure Solenoid

- Generator Rear Bearing Temperature Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

1122-04 [J1939] Engine Alternator Bearing 1 Temperature

- Generator Rear Bearing Temperature Sensor Short Low

Page 19: Codigos Emcp II Brk

[CDL] Rear System High Pressure Solenoid

- Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

1122-15

[J1939] Engine Alternator Bearing 1 Temperature [CDL] Rear System High Pressure Solenoid - Data Valid but above Normal Operating Range (least severe)

- High Rear Generator Bearing Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

1122-17

[J1939] Engine Alternator Bearing 1 Temperature [CDL] Rear System High Pressure Solenoid - Data Valid But Below Normal Operating Range (least severe)

- Low Generator Rear Bearing Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

1124-00

[J1939] Engine Alternator Winding 1 Temperature [CDL] Anti-Theft Solenoid - Data Valid but above Normal Operating Range (most severe)

- High Generator Winding #1 Temperature Shutdown - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1124-15

[J1939] Engine Alternator Winding 1 Temperature [CDL] Anti-Theft Solenoid - Data Valid but above Normal Operating Range (least severe)

- High Generator Winding #1 Temperature Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1125-00

[J1939] Engine Alternator Winding 2 Temperature [CDL] Left Hand Lever Forward - Data Valid but above Normal Operating Range (most severe)

- High Generator Winding #2 Temperature Shutdown - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1125-15

[J1939] Engine Alternator Winding 2 Temperature [CDL] Left Hand Lever Forward - Data Valid but above Normal Operating Range (least severe)

- High Generator Winding #2 Temperature Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1126-00

[J1939] Engine Alternator Winding 3 Temperature [CDL] Left Hand Lever Left - Data Valid but above Normal Operating Range (most severe)

- High Generator Winding #3 Temperature Shutdown - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1126-15 [J1939] Engine Alternator Winding 3 - High Generator Winding #3

Page 20: Codigos Emcp II Brk

Temperature [CDL] Left Hand Lever Left - Data Valid but above Normal Operating Range (least severe)

Temperature Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1231-11

[J1939] J1939 Network #2 [CDL] Brake Oil Diverter Solenoid - Failure Mode Not Identifiable

- Accessory Data Link Fault - Data Link Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

1239-31

[J1939] Engine Fuel Leakage 1 [CDL] Hoist Control to Tank Head Solenoid - Not Available Or Condition Exists

- Fuel Tank Leak (Fuel Rupture Basin) - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

1383-11

[J1939] Engine was Shut Down Hot [CDL] Gen Stat Winding #5 Temp Sens open - Failure Mode Not Identifiable

- Unexpected Engine Shutdown - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1390-00

[J1939] Engine Fuel Valve 1 Inlet Absolute Pressure [CDL] Gen Stat Winding #12 Temp Sens open - Data Valid but above Normal Operating Range (most severe)

- High Gas Pressure Shutdown - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1390-01

[J1939] Engine Fuel Valve 1 Inlet Absolute Pressure [CDL] Gen Stat Winding #12 Temp Sens open

- Low Gas Pressure Shutdown - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1390-15

[J1939] Engine Fuel Valve 1 Inlet Absolute Pressure [CDL] Gen Stat Winding #12 Temp Sens open - Data Valid but above Normal Operating Range (least severe)

- High Gas Pressure Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1390-17

[J1939] Engine Fuel Valve 1 Inlet Absolute Pressure [CDL] Gen Stat Winding #12 Temp Sens open - Data Valid But Below Normal Operating Range (least severe)

- Low Gas Pressure Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

1664-31

[J1939] Engine Automatic Start Failed [CDL] Attachment Valve #4 Retract Pressure Solenoid

- Engine Failure to Start Shutdown - Engine Overcrank Warning - 4490 - ELECTRONIC

Page 21: Codigos Emcp II Brk

- Not Available Or Condition Exists

MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2433-00

[J1939] Engine Exhaust Exhaust Gas Temperature - Right Manifold [CDL] Urea Tank Level Switch - Data Valid but above Normal Operating Range (most severe)

- High Right Exhaust Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2433-01

[J1939] Engine Exhaust Exhaust Gas Temperature - Right Manifold [CDL] Urea Tank Level Switch

- Low Right Exhaust Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2433-03

[J1939] Engine Exhaust Exhaust Gas Temperature - Right Manifold [CDL] Urea Tank Level Switch

- Right Exhaust Temperature Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2433-04

[J1939] Engine Exhaust Exhaust Gas Temperature - Right Manifold [CDL] Urea Tank Level Switch

- Right Exhaust Temperature Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2433-08

[J1939] Engine Exhaust Exhaust Gas Temperature - Right Manifold [CDL] Urea Tank Level Switch

- Right Exhaust Temperature Signal Abnormal - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

2433-15

[J1939] Engine Exhaust Exhaust Gas Temperature - Right Manifold [CDL] Urea Tank Level Switch - Data Valid but above Normal Operating Range (least severe)

- High Right Exhaust Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2433-17

[J1939] Engine Exhaust Exhaust Gas Temperature - Right Manifold [CDL] Urea Tank Level Switch - Data Valid But Below Normal Operating Range (least severe)

- Low Right Exhaust Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2434-00

[J1939] Engine Exhaust Exhaust Gas Temperature - Left Manifold [CDL] Engine Load Signal - Data Valid but above Normal Operating Range (most severe)

- High Left Exhaust Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2434-01 [J1939] Engine Exhaust Exhaust Gas - Low Left Exhaust

Page 22: Codigos Emcp II Brk

Temperature - Left Manifold [CDL] Engine Load Signal

Temperature Shutdown - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2434-03

[J1939] Engine Exhaust Exhaust Gas Temperature - Left Manifold [CDL] Engine Load Signal

- Left Exhaust Temperature Sensor Short High - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2434-04

[J1939] Engine Exhaust Exhaust Gas Temperature - Left Manifold [CDL] Engine Load Signal

- Left Exhaust Temperature Sensor Short Low - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2434-08

[J1939] Engine Exhaust Exhaust Gas Temperature - Left Manifold [CDL] Engine Load Signal

- Left Exhaust Temperature Signal Abnormal - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

2434-15

[J1939] Engine Exhaust Exhaust Gas Temperature - Left Manifold [CDL] Engine Load Signal - Data Valid but above Normal Operating Range (least severe)

- High Left Exhaust Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2434-17

[J1939] Engine Exhaust Exhaust Gas Temperature - Left Manifold [CDL] Engine Load Signal - Data Valid But Below Normal Operating Range (least severe)

- Low Left Exhaust Temperature Warning - Digital Input Circuit Fault - Analog Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2436-00

[J1939] Generator Average AC Frequency [CDL] Catalytic Converter Differential Pressure Sensor - Data Valid but above Normal Operating Range (most severe)

- Generator Over Frequency Shutdown - Generator Overfrequency Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2436-01

[J1939] Generator Average AC Frequency [CDL] Catalytic Converter Differential Pressure Sensor

- Generator Under Frequency Shutdown - Generator Underfrequency Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2436-02 [J1939] Generator Average AC Frequency

- Engine Speed-Generator Output Frequency Mismatch Warning

Page 23: Codigos Emcp II Brk

[CDL] Catalytic Converter Differential Pressure Sensor

- Engine Speed Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2436-12

[J1939] Generator Average AC Frequency [CDL] Catalytic Converter Differential Pressure Sensor - Bad Device or Component

- Generator Output Sensing System Failure - Generator Output Sensing Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2436-15

[J1939] Generator Average AC Frequency [CDL] Catalytic Converter Differential Pressure Sensor - Data Valid but above Normal Operating Range (least severe)

- Generator Over Frequency Warning - Generator Overfrequency Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2436-17

[J1939] Generator Average AC Frequency [CDL] Catalytic Converter Differential Pressure Sensor - Data Valid But Below Normal Operating Range (least severe)

- Generator Under Frequency Warning - Generator Underfrequency Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2440-00

[J1939] Generator Average Line-Line AC RMS Voltage [CDL] Winch Brake Solenoid - Data Valid but above Normal Operating Range (most severe)

- Generator Over Voltage Shutdown - Generator Overvoltage Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2440-01

[J1939] Generator Average Line-Line AC RMS Voltage [CDL] Winch Brake Solenoid

- Generator Under Voltage Shutdown - Generator Undervoltage Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2440-15

[J1939] Generator Average Line-Line AC RMS Voltage [CDL] Winch Brake Solenoid - Data Valid but above Normal Operating Range (least severe)

- Generator Over Voltage Warning - Generator Overvoltage Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2440-17

[J1939] Generator Average Line-Line AC RMS Voltage [CDL] Winch Brake Solenoid - Data Valid But Below Normal Operating Range (least severe)

- Generator Under Voltage Warning - Generator Undervoltage Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2448-00 [J1939] Generator Average AC RMS - Generator Over Current

Page 24: Codigos Emcp II Brk

Current [CDL] Graphical Display Module - Data Valid but above Normal Operating Range (most severe)

Shutdown - Generator Overcurrent Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2448-15

[J1939] Generator Average AC RMS Current [CDL] Graphical Display Module - Data Valid but above Normal Operating Range (least severe)

- Generator Over Current Warning - Generator Overcurrent Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2452-01

[J1939] Generator Total Real Power [CDL/ATA] Particulate Trap #1 Intake Temperature Sensor

- Generator Reverse Power Shutdown - Generator Reverse Power Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2452-15

[J1939] Generator Total Real Power [CDL/ATA] Particulate Trap #1 Intake Temperature Sensor - Data Valid but above Normal Operating Range (least severe)

- Generator High Power Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

2452-17

[J1939] Generator Total Real Power [CDL/ATA] Particulate Trap #1 Intake Temperature Sensor - Data Valid But Below Normal Operating Range (least severe)

- Generator Reverse Power Warning - Generator Reverse Power Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

2648-31

[J1939] Maintenance Lamp [CDL] Cylinder #24 Injector Actuator #2 - Not Available Or Condition Exists

- Service Maintenance Interval Warning - Service Maintenance Interval Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

3543-09 [J1939] Engine Operating State

- Engine Controller Not Responding - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3546-11 Utility Breaker - Failure Mode Not Identifiable

- Utility Breaker System Fault - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3783-31

[J1939] Inlet Manifold Charge Combustion - Not Available Or Condition Exists

- Engine Inlet Manifold Charge Combustion - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3829-31 [J1939] EPS Supplying Load - EPS Supplying Load

Page 25: Codigos Emcp II Brk

- Not Available Or Condition Exists

- 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3880-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #17 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3881-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #18 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3882-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #19 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3883-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #20 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3888-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #21 - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3889-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #22 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3890-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #23 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3891-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #24 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3892-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #25 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3893-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #26 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3894-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #27 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3895-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #28 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3896-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #29 Status - 7569 -TROUBLESHOOTING PROCEDURE

Page 26: Codigos Emcp II Brk

- 7566 - WIRING DIAGRAM

3897-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #30 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3898-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #31 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3899-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #32 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3904-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #33 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3905-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #34 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3906-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #35 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3907-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #36 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3908-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #37 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3909-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #38 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3910-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #39 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3911-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #40 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3912-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #41 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3913-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #42 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

Page 27: Codigos Emcp II Brk

3914-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #43 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3915-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #44 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3920-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #45 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3921-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #46 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3922-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #47 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3923-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #48 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3924-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #49 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3925-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #50 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3926-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #51 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3927-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #52 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3928-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #53 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3929-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #54 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3930-31 [J1939] Auxiliary I - Not Available Or Condition Exists

- Custom Event #55 Status - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

3931-31 [J1939] Auxiliary I

- Custom Event #56 Status - 7569 -TROUBLESHOOTING

Page 28: Codigos Emcp II Brk

- Not Available Or Condition Exists PROCEDURE - 7566 - WIRING DIAGRAM

4000-31

[J1939] Engine Exhaust Brake Enable Switch - Not Available Or Condition Exists

- Air Damper Closed - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

4001-31 ATS in Normal Position - Not Available Or Condition Exists

- ATS in Normal Position - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

4002-31 ATS in Emergency Position - Not Available Or Condition Exists

- ATS in Emergency Position - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

4003-31 Battery Charger Failure - Not Available Or Condition Exists

- Battery Charger Failure - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

4004-31 Generator Circuit Breaker Closed - Not Available Or Condition Exists

- Generator Circuit Breaker Closed - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

4005-31 Utility Circuit Breaker Closed - Not Available Or Condition Exists

- Utility Circuit Breaker Closed - Digital Input Circuit Fault - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

4006-31 Engine in Cooldown - Not Available Or Condition Exists

- Engine in Cooldown - Engine Cooldown Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

4007-31

Generator Control Not in Automatic Warning - Not Available Or Condition Exists

- Generator Control Not in Automatic Warning - Generator Control Not in Automatic Warning - 4490 - ELECTRONIC MODULAR CONTROL PANEL - 7566 - WIRING DIAGRAM

4009-31 Generator Breaker Failure to Open - Not Available Or Condition Exists

- Generator Breaker Failure to Open - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4010-31 Utility Breaker Failure to Open - Not Available Or Condition Exists

- Utility Breaker Failure to Open - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

Page 29: Codigos Emcp II Brk

4011-31 Generator Breaker Failure to Close - Not Available Or Condition Exists

- Generator Breaker Failure to Close - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4012-31 Utility Breaker Failure to Close - Not Available Or Condition Exists

- Utility Breaker Failure to Close - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4013-31 Generator Circuit Breaker Open - Not Available Or Condition Exists

- Generator Circuit Breaker Open - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4014-31 Utility Breaker Open - Not Available Or Condition Exists

- Utility Breaker Open - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4015-00

Utility to Generator Transfer Failure Shutdown - Data Valid but above Normal Operating Range (most severe)

- Utility to Generator Transfer Failure Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4015-15

Utility to Generator Transfer Failure Shutdown - Data Valid but above Normal Operating Range (least severe)

- Utility to Generator Transfer Failure Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4016-15

Generator to Utility Transfer Failure Warning - Data Valid but above Normal Operating Range (least severe)

- Generator to Utility Transfer Failure Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4017-31 Loss of Utility - Not Available Or Condition Exists

- Loss of Utility - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4018-31 Generator Breaker Locked Out - Not Available Or Condition Exists

- Generator Breaker Locked Out - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4019-31 Utility Breaker Locked Out - Not Available Or Condition Exists

- Utility Breaker Locked Out - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4028-31 Earth Fault - Not Available Or Condition Exists

- Earth Fault - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

4029-31 Earth Leakage - Not Available Or Condition Exists

- Earth Leakage - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

Page 30: Codigos Emcp II Brk

4256-17

[J1939] Cranking Voltage - Data Valid But Below Normal Operating Range (least severe)

- Low Battery Cranking Voltage Warning - 7569 -TROUBLESHOOTING PROCEDURE - 7566 - WIRING DIAGRAM

Component Based Troubleshooting is for technical reference only. It is not intended to replace the knowledge and skills of the servicing technician, and does NOT imply warranty coverage. Content Owner: Brian Hall Caterpillar Confidential: Green Copyright 2004 - 2011 Caterpillar Inc. All Rights Reserved.