7
WWW.LUMENWERX.COM www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CLUSTER-RECESSED-MILWORK-MOUNTING-INST November 12, 2019 Page: 1 / 7 LumenWerx ULC. reserves the right to change or modify product specifications without notification MILLWORK WOOD MOUNT - INSTALLATION INSTRUCTIONS CLUSTER NOTE: Wire dimming conductors as Class 1 CUT-OUT DIMENSIONS Linear DownLight & Wall Washer CLUSTERS DIMENSIONS MWTL MWFT Clearance Height CLUC01 1.300” x 1.300” 1.425” x 1.425” 4” CLUC02 2.500” x 1.300” 2.625” x 1.425” 4” CLUC03 3.700” x 1.300” 3.825” x 1.425” 8” CLUC05 6.100” x 1.300” 6.225” x 1.425” 6” CLUC10 12.100” x 1.300” 12.275” x 1.425” 8” Planar DownLight CLUC22 2.500” x 2.500” 2.625” x 2.625” 6” CLUC33 5.700” x 5.700” 3.825” x 3.825” 6” CLUC55 6.100” x 6.100” 6.225” x 6.225” 4” Cluster 3x3, 5x5, 10x1 do not install with insulation directly on the fixture. MILLWORK JIG INCLUDED 3M COMMAND POSTER STRIP #136 (QTY. 40) INCLUDED ROUTER NOT INCLUDED WOOD CHISEL NOT INCLUDED 5/16 MINIATURE RABBETING BIT WITH 1/8’’ CUR DEPTH INCLUDED (FOR TRIMLESS ONLY) DRILL BIT TO START HOLE NOT INCLUDED

CLUSTER - Lumenwerx · 2019-11-12 · Flush with surface Final result section view. Make the connection between the driver quick connector (U) and the fixture using the quick

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CLUSTER - Lumenwerx · 2019-11-12 · Flush with surface Final result section view. Make the connection between the driver quick connector (U) and the fixture using the quick

W W W . L U M E N W E R X . C O M

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CLUSTER-RECESSED-MILWORK-MOUNTING-INST November 12, 2019 Page: 1 / 7

LumenWerx ULC. reserves the right to change or modify product specifications without notification

MILLWORK WOOD MOUNT - INSTALLATION INSTRUCTIONSCLUSTER NOTE: Wire dimming conductors as Class 1

CUT-OUT DIMENSIONS

Linear DownLight &

Wall Washer

CLUSTERS DIMENSIONS

MWTL MWFT Clearance Height

CLUC01 1.300” x 1.300” 1.425” x 1.425” 4”

CLUC02 2.500” x 1.300” 2.625” x 1.425” 4”

CLUC03 3.700” x 1.300” 3.825” x 1.425” 8”

CLUC05 6.100” x 1.300” 6.225” x 1.425” 6”

CLUC10 12.100” x 1.300” 12.275” x 1.425” 8”

Planar DownLight

CLUC22 2.500” x 2.500” 2.625” x 2.625” 6”

CLUC33 5.700” x 5.700” 3.825” x 3.825” 6”

CLUC55 6.100” x 6.100” 6.225” x 6.225” 4”

Cluster 3x3, 5x5, 10x1 do not install with insulation directly on the fixture.

MILLWORK JIGINCLUDED

3M COMMAND POSTER STRIP #136 (QTY. 40)

INCLUDED

ROUTERNOT INCLUDED

WOOD CHISELNOT INCLUDED

5/16 MINIATURE RABBETING BIT WITH 1/8’’ CUR DEPTH

INCLUDED(FOR TRIMLESS ONLY)

DRILL BIT TO START HOLENOT INCLUDED

Page 2: CLUSTER - Lumenwerx · 2019-11-12 · Flush with surface Final result section view. Make the connection between the driver quick connector (U) and the fixture using the quick

W W W . L U M E N W E R X . C O M

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CLUSTER-RECESSED-MILWORK-MOUNTING-INST November 12, 2019 Page: 2 / 7

LumenWerx ULC. reserves the right to change or modify product specifications without notification

CLUSTER

1 2

5

3

64

MILLWORK WOOD MOUNT - INSTALLATION INSTRUCTIONS

* *

C

Make the pre-drill holes with the drill bit (C) into the wood ceiling.

B

BD

BA

B

Remove the Millwork jig (B) once cut has been completed.

Using the router (D) create hole with the help of the millwork jig (B).

Align and install the Millwork jig (B) onto the wood ceiling surface.Prepare and clean wood surface.

Place the double sided adhesive (A) onto the Millwork jig (B)

Page 3: CLUSTER - Lumenwerx · 2019-11-12 · Flush with surface Final result section view. Make the connection between the driver quick connector (U) and the fixture using the quick

W W W . L U M E N W E R X . C O M

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CLUSTER-RECESSED-MILWORK-MOUNTING-INST November 12, 2019 Page: 3 / 7

LumenWerx ULC. reserves the right to change or modify product specifications without notification

CLUSTER

7 8

11

MILLWORK WOOD MOUNT - INSTALLATION INSTRUCTIONS

9

1210 STANDARD INTEGRAL DRIVER BOX

FOR TRIMLESS ONLYFOR TRIMLESS ONLYFOR TRIMLESS ONLY

IG

HH

KFJ

CD

D

E

D

Unfasten the screw (I) and pivot the cover (J). Bring the FT-6 cable (K) into the driver box (H).

Secure the integral driver box (H) on a solid surface using screws (G). Near the Cut Opening of the fixture.Use a wood chisel (F) to square all corners.

Create the trim recess on the visible surface side for the fixture to sit onto. Remove the router (C) once done.

Set depth of rabbeting bit (D) to the height of the trim of the fixture (E) of 1/8’’

1/8’’

Install the 5/16’’ Miniature rabbeting tool (D) with a 1/16’’ cut depth.

Page 4: CLUSTER - Lumenwerx · 2019-11-12 · Flush with surface Final result section view. Make the connection between the driver quick connector (U) and the fixture using the quick

W W W . L U M E N W E R X . C O M

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CLUSTER-RECESSED-MILWORK-MOUNTING-INST November 12, 2019 Page: 4 / 7

LumenWerx ULC. reserves the right to change or modify product specifications without notification

CLUSTER

13

16 17

14

MILLWORK WOOD MOUNT - INSTALLATION INSTRUCTIONS

15

18

Q

P

Loosen the screws (I) holding the cover (P) in place. Slide and open the cover (P). Bring the FT-6 cable (Q) into the remote driver box (R).

R

G

O

Secure the remote driver box (O) on a secure surface using screws (G). Skip this step for 1x1 and 1x2.

1X1, 1X2 INTEGRAL DRIVER BOX

N

M

Unscrew to remove the cover (M). Make the electrical connection between the integral driver box (N) and power chord (K) with the marettes (L). Close the cover (J) and reinstall the screw (I). 1x1 and 1x2 max 3 wires in.

Please refer to the remote driver installation sheet for more informations.

REMOTE DRIVER BOX

Q

R

IS

P

K

L

IL J

K

Make the electrical connection between the remote driver box (R) and the FT-6 cable (Q) with the marettes (S). Close the cover (P) and tighten the screws (I). Number of wires may vary.

Make the electrical connection between the integral driver box (H) and the power chord (K) with the marettes (L). Close the cover (J) and reinstall the screw (I). 1x3, 1x5 and 2x2 models max 5 wires in.

Page 5: CLUSTER - Lumenwerx · 2019-11-12 · Flush with surface Final result section view. Make the connection between the driver quick connector (U) and the fixture using the quick

W W W . L U M E N W E R X . C O M

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CLUSTER-RECESSED-MILWORK-MOUNTING-INST November 12, 2019 Page: 5 / 7

LumenWerx ULC. reserves the right to change or modify product specifications without notification

CLUSTER

19 20

MILLWORK WOOD MOUNT - INSTALLATION INSTRUCTIONS

22 23

21

24 TRIMTRIM

TRIMLESS

TRIM

TRIMLESSTRIMLESS

T

U

Make the connection between the driver quick connector (U) and the fixture using the quick connectors (T).

Wood Ceiling

Fixture

W

OT

U

W

V

Final result section view. Compress the springs (O). Upwards and place the fixture (W) into the cut out.

Wood Ceiling

Fixture

Flush with surface

Final result section view.

Make the connection between the driver quick connector (U) and the fixture using the quick connectors (T).

Compress the springs (V). Upwards and place the fixture (W) into the cut out.

Page 6: CLUSTER - Lumenwerx · 2019-11-12 · Flush with surface Final result section view. Make the connection between the driver quick connector (U) and the fixture using the quick

W W W . L U M E N W E R X . C O M

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CLUSTER-RECESSED-MILWORK-MOUNTING-INST November 12, 2019 Page: 6 / 7

LumenWerx ULC. reserves the right to change or modify product specifications without notification

CLUSTER

25 26

MILLWORK WOOD MOUNT - INSTALLATION INSTRUCTIONS

28 29

27

301X1, 1X2 INTEGRAL DRIVER BOX

DRIVER REPLACEMENT

J

N

M

V

L

H

T

UH

Unscrew to detach the driver box(H). Drag the driver through the cut out.

Unfaten the screw and pivot the cover(J). Disconncet the wires to replace the driver box.

Pull the driver box(N) down through the cut out. Unscrew to remove the cover(M). Disconnect the wires.

Replace to the new driver(V). Make the electrical connection with the marettes(L) by fasten the screws. Push the driver through the fixture cut-out. Screw to attach the driver box(H).

Disconnect between the driver quick connector (U) and the fixture using the quick connectors (T).

Page 7: CLUSTER - Lumenwerx · 2019-11-12 · Flush with surface Final result section view. Make the connection between the driver quick connector (U) and the fixture using the quick

W W W . L U M E N W E R X . C O M

www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:CLUSTER-RECESSED-MILWORK-MOUNTING-INST November 12, 2019 Page: 7 / 7

LumenWerx ULC. reserves the right to change or modify product specifications without notification

CLUSTER

31

MILLWORK WOOD MOUNT - INSTALLATION INSTRUCTIONS

W