CAREpoint – Rosetta
12-Lead Solutions
March, 2011
Improving Communications and Information Management for Emergency Medicine
2
Overview:
About General Devices
System Components Rosetta - CAREpoint
12 Lead Transmission Methods
Rosetta Transmission
Interfacing with 3rd Party Systems
About General Devices Established 1979 31+ years
25+ years of experience in Telemedicine
20+ years of experience in EMS & ED User-friendly, configurable systems
Over 800 hospitals & EMS installations
All forms of wireless and landline communications
Day-Day EMS, Disaster Response & EMS Telemedicine
Improving Communications and Information
Management in Emergency Medicine
3
Sampling of GD Customers
FDNY Telemetry & EMS
University of Chicago
Charleston SC Region 7 (all)
Cincinnati Children’s Hosp
Loma Linda UMC CA
SSM Health Care
Baton Rouge Parish LA (all)
Centegra Health System
Virtua Health Medcom
Nassau UMC Medcom & EMS
HCA Health Care
Resurrection Health Care
Banner Health System AZ
Wellmont Healthcare TN
Baptist First Health
Southern IL Health System
Atlanticare Health Services
Milwaukee County EMS
All Saints Health Care
Advocate Health
Provena Health
Brandywine SkyFlight Comm
Veterans Administration
Riverside Health
From small community hospitals and EMS squads
to large medical centers and region-wide systems
4
CAREpoint & Rosetta: A universal approach
to 12-Lead Transmission and STEMI treatment
Philips MRx
Life Pak 12 &15
Zoll E & M Series5
CAREpoint
Workstation
CAREpoint Workstation
Full ED Solution
Communications Voice & Data Radio, Cellular & Landline Internet Capable Interfaces with all current 12 lead
systems Networked – Remote Access for
supervisors Print Single & 12 Lead ECG on any
networked computer
400+ Systems Installed
6
7
12 Lead Transmission:CAREpoint Workstation Capabilities
Receiving Rosetta
Fax
e-mail (PDF)
ECG Display Live during transmission
Printing Local/Network printer
Forwarding Fax
e-mail PDA/PC
Telemetry Viewer PC
Documentation (storage) QA Review
Rosetta-Rx
(Basic print-out only solution)
Receive from Rosetta-Lt:
Single Lead
12-Lead Reports
Communications (Input):
2-Way Radio (receive pair)
Phone line (GSM Cell, Landline)
Printing (Output):
HP LaserJet (or compatible)
printer with “parallel port”
Fully Automatic Operation
8
Stores the 12-lead for 20 minutes
Transmit from scene or en route
Uses existing radio system
No need for monthly cell phone fees
Transmits single lead
Sends standard ECG strips
Cable connection to most radios
Keys the radio for you
Hands free operation with direct cable
connection
Single button operation
Receives digital 12 lead files from the monitor and “translates” them to a format for transmission by analog radio or certain cell phones…
Rosetta-Lt Analog Transmission Solution
9
Rosetta-DS Operates on MS Windows™
based PC’s & tablet
Use the same equipment for e-PCR’s
Bluetooth or Cable
Choose what works best
User Data Entry
Add Pt identifiers & info
Stores the 12-lead
Transmit from scene or en route
Works with digital radio systems
No monthly cell phone/data fees
Works with cellular aircards & gateways
Use your existing phone, aircard or gateway
Rosetta-D Series Digital Transmission Solution
Rosetta-DS
10
Rosetta Monitor Compatibility
Compatible with:
MRx
LP12 &15
M & E-Series
Data Types:
Single Lead (Rosetta-Lt)
12-Lead Reports
Vitals (MRx only)
11
12
Rosetta & CAREpoint 12 Lead Solutions
CAREpoint
Rosetta-Lt
Rosetta-DS
Analog
Radio / Phone
Digital
Radio
EMS
Monitors *
BT or cable
cable
GD-Net (web server)
Air-card
or Mobile
Gateway
Rosetta-Rx
CAREpoint-FS
(Forward Service)e-Mail /Fax
SSL 128 Bit
* Physio Monitors
Require Rosetta-Lt
and RCA for use with
Rosetta-DS
13
Rosetta-Lt with RCA “Rosetta Communications Adapter”
for use with Physio-Control monitors
CAREpointWorkstation
Rosetta-Lt
(with RCA)
Radio (IV&D)
Aircard/Router
(digital data)
Rosetta-DS(communications
software)
CAREpoint-FS (web Forward Service to email/fax)
GD-Net (web server)
LP15/LP12
Monitors*
* The Rosetta-Lt with RCA is required for use with LP12 and LP15 monitors and Rosetta-DS
digital transmission. ZOLL and Philips monitors can connect to the Rosetta-DS directly
without the Rosetta-Lt.
(Cable) (Cable or BT)
CAREpoint 12-Lead Receiving / Forwarding
CAREpoint
Fax
Printers
Telemetry
Reviewer
e-Mail PDF
PC, PDA3rd Party
Systems 14
MUSE &
Epiphany
e-Net
Messenger
15
CAREpoint-FS: A Building Block for
Rosetta-DS Transmission
CAREpoint
Rosetta-DS
Digital
Radio GD-Net
(web server)
Air-card
or Mobile
Gateway CAREpoint-FS (web Forward Service)
e-Mail / Fax
16
True “Vendor-Neutral”12-Lead Management
CAREpoint
EMS
Varied Monitors
3rd Party Server:•Physio LIFENET CCS
•Philips Transfer Station
•ZOLL Data
or
Cell / Aircard
Data
Fax / e-mail
Fax
Printers
Telemetry
Reviewer
e-Mail PDF
PC, PDA
Rosetta Lt / DS
MUSE
e-Net
Messenger
17
12-Lead Transmission to:CAREpoint from ZOLL / Philips (w/o Rosetta)
CAREpoint
EMS
ZOLL/Philips
Monitors3rd Party Server
Data/Fax
Fax / e-mail
Fax / e-mail / Print
Using the monitor companies transmission schemes(i.e. Bluetooth > Cell phone with data connection > their server)
Fax or e-mail – Forward from 3rd party (monitor) server system Philips Transfer Station, ZOLL Data
Fax direct ZOLL with Tellular fax equipment
18
CAREpoint
EMS Physio
LP12, LP15
Monitors Physio LIFENET CCS
w/Physio
Alert Client
Running the LIFENET Client Software on CAREpoint for simplified work flow
12-Lead Transmission to:CAREpoint from Physio LIFENET (w/o Rosetta)
19
CAREpointw/LIFENET Adapter
ZOLL / Physio
Monitors
Physio LIFENET CCS
Rosetta
Radio
Phone
Cell
w/Physio
Alert Client
Benefits systems using both Rosetta-CAREpoint and Physio LIFENET transmission schemes
12-Lead Transmission to:Physio LIFENET via CAREpoint (with Rosetta)
Fax / e-mail
Fax / e-mail / Print
Questions?
Visit www.general-devices.com for the latest information
General Devices
1000 River St
Ridgefield, NJ 07657 USA
(201) 313-7075