18
SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187 Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187 CARTIERA DI CARBONERA Spa - Via Borgo Padova 69, 35012 Camposanpiero (PD) Tel. +39 049 57 90 744 - Fax +39 049 57 93 492 - [email protected] TEST UNIT RANGE STANDARD Grammatura - Basis Weight gr/m 2 +/- 3% 120 140 175 200 UNI 6440 KPA/m 2 /gr +/- 5% 3,10 3,10 3,10 3,00 TAPPI 403 RCT - Avarange value KN/m +/- 5% 1,20 1,35 1,50 1,90 TAPPI STAND. T822 SCT CD - Avarange value KN/m +/- 5% 2,55 3,14 3,45 3,70 ISO 9895 COBB a 60” - Top layer gr/m 2 H2O 35 35 35 35 ISO 535 Umidità - Moisture % +/- 1% 7,0 7,0 7,0 7,0 TAPPI 412-83 Diametro Bobina - Reel Diameter 127 > 140 Valido da / Valid from : 01/01/2019 VALORI NOMINALI / NOMINAL VALUES Indice di Scoppio - Burst index

CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

  • Upload
    others

  • View
    5

  • Download
    1

Embed Size (px)

Citation preview

Page 1: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

CARBO KRAFTCEPI Code: 90Denominazione / Denomination: CK

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

CARTIERA DI CARBONERA Spa - Via Borgo Padova 69, 35012 Camposanpiero (PD)Tel. +39 049 57 90 744 - Fax +39 049 57 93 492 - [email protected]

TEST UNIT RANGE STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 120 140 175 200 UNI 6440

KPA/m2/gr +/- 5% 3,10 3,10 3,10 3,00 TAPPI 403

RCT - Avarange value KN/m +/- 5% 1,20 1,35 1,50 1,90TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 5% 2,55 3,14 3,45 3,70 ISO 9895

COBB a 60” - Top layergr/m2

H2O35 35 35 35 ISO 535

Umidità - Moisture % +/- 1% 7,0 7,0 7,0 7,0 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 140 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

Indice di Scoppio - Burst index

Page 2: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

CARBO WHITE TOPCEPI Code: 91Denominazione / Denomination: CWT

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

CARTIERA DI CARBONERA Spa - Via Borgo Padova 69, 35012 Camposanpiero (PD)Tel. +39 049 57 90 744 - Fax +39 049 57 93 492 - [email protected]

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 120 150 175 UNI 6440

KPA/m2/gr +/- 5% 3,2 3,2 3,0 TAPPI 403

Grado di bianco - Whitness Photovolt +/- 3% 74 74 74 ISO 2470

RCT - Avarange value KN/m +/- 5% 1,30 1,60 1,90TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 5% 2,30 2,45 2,60 TAPPI 826

COBB a 60” - Top layergr/m2

H2O30 30 30 ISO 535

Umidità - Moisture % +/- 1% 7,0 7,0 7,0 TAPPI 412-83

Scott bond J-m2 - >250 >250 >250 UNI 9439

Liscio bendtsen ml/min - <500 <500 <500 ISO 53636/3

Diametro Bobina - Reel Diameter 127 > 140 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

Indice di Scoppio - Burst index

Page 3: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

IDRO PRO SHCEPI Code: 44Denominazione / Denomination: IDR

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 112 120 140 150 180 200 UNI 6440

CMT 30 N +/- 6% 194 230 265 272 N.R N.R ISO 7263

SCT CD - Avarange value KN/m +/- 6% 2,64 2,20 3,02 3,25 3,71 3,90 TAPPI 826

Umidità - Moisture % +/- 1% 8 8 8 8 8 8 44

Diametro Bobina - Reel Diameter 127 > 145 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

CARTITALIA Srl - Via Motte, 50 - 44026 Mesola (FE)Tel. +39 0533 99 35 71 - Fax +39 0533 99 35 66 - [email protected]

Page 4: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

MEDIUMCEPI Code: 43Denominazione / Denomination: MED

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

TEST UNIT RANGE STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 105 120 127 140 150 UNI 6440

CMT 30 - Avarange value N +/- 5% 120 160 170 190 205 ISO 7263

CCT 30 CD - Avarange value KN/m +/- 5% 0,80 1,30 1,40 1,50 1,60 T 824-84

RCT CD - Avarange value KN/m +/- 5% 0,48 0,60 0,70 0,80 0,90 T 822

Umidità - Moisture % - 7 7 7 7 7 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 145 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

TOLENTINO Srl - Via Borgo Cartiere, 20 - 62029 Macerata (MC)Tel. +39 0733 956 601 - Fax +39 0733 966 401 - [email protected]

Page 5: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

TEST LINER BIANCO C CEPI Code: 72Denominazione / Denomination: TBC ( TBCC if Cobb requested)

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

CARTIERA DI CARBONERA Spa - Via Borgo Padova 69, 35012 Camposanpiero (PD)Tel. +39 049 57 90 744 - Fax +39 049 57 93 492 - [email protected]

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 125 140 150 180 UNI 6440

Indice di Scoppio - Burst index KPA/m2/gr +/- 5% <1,80 <1,80 <1,80 <1,80 TAPPI 403

Grado di bianco - Whitness Photovolt +/- 3% 65 65 65 65 ISO 2470

RCT - Avarange value KN/m +/- 5% 0,70 0,80 0,90 1,20TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 5% 1,40 1,60 1,60 1,97 TAPPI 826

COBB a 60” - Top layergr/m2

H2OISO 535

Umidità - Moisture % +/- 1% 7,0 7,0 7,0 7,0 TAPPI 412-83

Dennison wax test - Wax test - - >11 >11 >11 >11 T.459

Scott bond J-m2 - >250 >250 >250 >250 UNI 9439

Liscio bendtsen ml/min - <500 <500 <500 <500 ISO 53636/3

Diametro Bobina - Reel Diameter 127 > 140 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

If requested

-

30

-

30

-

30 30

- -

Page 6: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

TEST LINER BIANCO BCEPI Code: 71Denominazione / Denomination: TBB se collato TBBC (TBBC if Cobb requested)

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

CARTIERA DI CARBONERA Spa - Via Borgo Padova 69, 35012 Camposanpiero (PD)Tel. +39 049 57 90 744 - Fax +39 049 57 93 492 - [email protected]

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 125 135 180 UNI 6440

KPA/m2/gr +/- 5% 2,00 2,00 1,90 TAPPI 403

Grado di bianco - Whitness Photovolt +/- 3% 70 70 70 ISO 2470

RCT - Avarange value KN/m +/- 5% 0,80 0,90 1,20TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 5% 1,50 1,75 2,30 TAPPI 826

COBB a 60” - Top layergr/m2

H2OISO 535

Umidità - Moisture % +/- 1% 7,0 7,0 7,0 TAPPI 412-83

Dennison wax test - Wax test - - >11 >11 >11 T.459

Scott bond J-m2 - >250 >250 >250 UNI 9439

Liscio bendtsen ml/min - <500 <500 <500 ISO 53636/3

Diametro Bobina - Reel Diameter 127 > 140 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

If requested 30

--

30

-

30

-

Indice di Scoppio - Burst index

Page 7: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

TEST LINER 1 CEPI Code: 10Denominazione / Denomination: TL1

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 125 150 175 200 UNI 6440

KPA/m2/gr +/- 5% 2,80 2,80 2,70 2,70 ISO 2758

RCT CD KN/m +/- 5% 1,10 1,40 1,90 2,50TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 5% 2,20 2,65 3,20 3,50 TAPPI 826-86

COBB a 60” - Top layergr/m2

H2O- 35 35 35 35 ISO 535

Umidità - Moisture % +/- 1% 8 8 8 8 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 145 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

CARTITALIA Srl - Via Motte, 50 - 44026 Mesola (FE)Tel. +39 0533 99 35 71 - Fax +39 0533 99 35 66 - [email protected]

Indice di Scoppio - Burst index

Page 8: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

TEST LINER 2 CEPI Code: 21/20Denominazione / Denomination: T2 (T2C if Cobb requested)

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 125 150 175 200 UNI 6440

KPA/m2/gr +/- 5% 2,40 2,40 2,30 2,20 ISO 7263

RCT CD - Avarange value KN/m +/- 5% 0,90 1,20 1,60 1,80TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 5% 1,95 2,35 2,85 3,10 TAPPI 826

COBB a 60” - Top layergr/m2

H2OISO 535

Umidità - Moisture % +/- 1% 8 8 8 8 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 145 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

CARTITALIA Srl - Via Motte, 50 - 44026 Mesola (FE)Tel. +39 0533 99 35 71 - Fax +39 0533 99 35 66 - [email protected]

If requested 35

--

35

-

35 35

- -

Indice di Scoppio - Burst index

Page 9: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

TEST LINER 3 CEPI Code: 31/30Denominazione / Denomination: T3 (T3C if Cobb requested)

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 125 150 175 200 UNI 6440

KPA/m2/gr +/- 5% 2,00 2,00 1,90 1,80 ISO 7263

RCT CD - Avarange value KN/m +/- 5% 0,80 1,15 1,25 1,60TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 5% 1,85 2,30 2,45 2,85 TAPPI 826

COBB a 60” - Top layergr/m2

H2OISO 535

Umidità - Moisture % +/- 1% 8 8 8 8 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 145 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

CARTITALIA Srl - Via Motte, 50 - 44026 Mesola (FE)Tel. +39 0533 99 35 71 - Fax +39 0533 99 35 66 - [email protected]

If requested 35

--

35

-

35 35

- -

Indice di Scoppio - Burst index

Page 10: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

TEST LINER 3 CEPI Code: 21/20Denominazione / Denomination: T3 (T3C if Cobb requested)

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 125 150 175 200 UNI 6440

KPA/m2/gr +/- 5% 2,40 2,40 2,30 2,20 ISO 7263

RCT CD - Avarange value KN/m +/- 5% 0,90 1,20 1,60 1,80TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 5% 1,95 2,35 2,85 3,10 TAPPI 826

COBB a 60” - Top layergr/m2

H2OISO 535

Umidità - Moisture % +/- 1% 8 8 8 8 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 145 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

CARTITALIA Srl - Via Motte, 50 - 44026 Mesola (FE)Tel. +39 0533 99 35 71 - Fax +39 0533 99 35 66 - [email protected]

If requested 35

--

35

-

35 35

- -

Indice di Scoppio - Burst index

Page 11: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

TEST LINER 3 LEGGEROCEPI Code: 31/30Denominazione / Denomination: TL (TLC if Cobb requested)

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 85 90 100 110 120 UNI 6440

KPA/m2/gr +/- 5% 2,2 2,2 2,2 2,1 2,1 TAPPI 403

Grado di bianco - Whitness Photovolt +/- 3% ISO 2470

RCT - Avarange value KN/m +/- 5%TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 5% 1,35 1,45 1,6 1,75 1,95 TAPPI 826

COBB a 60” - Top layergr/m2

H2OISO 535

Umidità - Moisture % +/- 1% 8 8 8 8 8 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 150 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

CARTIERE VILLA LAGARINA Srl - Via A. Pesenti, 1 - 38060 Villa Lagarina (TN)Tel. +39 0464 411 511 - Fax +39 0464 410 400 - [email protected]

If requested 35

--

35 35

- -

35 35

- -

Indice di Scoppio - Burst index

Page 12: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

TEST LINER 4CEPI Code: 38Denominazione / Denomination: T4

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

TEST UNIT RANGE STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 110 120 140 175 UNI 6440

KPA/m2/gr +/- 5% 1,70 1,70 1,70 1,50 ISO 2758

SCT CD - Avarange value KN/m +/- 5% 1,10 1,15 1,40 1,65TAPPI826-86

RCT CD - Avarange value KN/m +/- 5% 0,60 0,70 0,90 1,10TAPPI STAND.

T822

Umidità - Moisture % +/- 5% 7 7 7 7 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 145 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

TOLENTINO Srl - Via Borgo Cartiere, 20 - 62029 Macerata (MC)Tel. +39 0733 956 601 - Fax +39 0733 966 401 - [email protected]

Indice di Scoppio - Burst index

Page 13: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 90 100 110 120 125 UNI 6440

CMT 30 - Avarange value N +/- 5% 135 155 175 200 210 ISO 7263

SCT CD - Avarange value KN/m +/- 5% 1,45 1,6 1,75 1,9 2 T 824-84

KPA/m2/gr +/- 5% 1,90 2,00 2,00 2,00 2,00 T 412-83

Umidità - Moisture % +/- 1% 7,5 7,5 7,5 7,5 7,5

Diametro Bobina - Reel Diameter 127 > 150 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

UNICARTACEPI Code: 52Denominazione / Denomination: UNI

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

CARTIERE VILLA LAGARINA Srl - Via A. Pesenti, 1 - 38060 Villa Lagarina (TN)Tel. +39 0464 411 511 - Fax +39 0464 410 400 - [email protected]

Indice di Scoppio - Burst index

Page 14: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% UNI 6440

CMT 30 - Avarange value N +/- 5% ISO 7263

SCT CD - Avarange value KN/m +/- 5% T 824-84

KPA/m2/gr +/- 5% T 412-83

Umidità - Moisture % +/- 1%

Diametro Bobina - Reel Diameter 127 > 150 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

CARTIERE VILLA LAGARINA Srl - Via A. Pesenti, 1 - 38060 Villa Lagarina (TN)Tel. +39 0464 411 511 - Fax +39 0464 410 400 - [email protected]

Indice di Scoppio - Burst index

105

165

1,68

2,00

7,5

100

155

1,6

2,00

7,5

110

175

1,75

2,00

7,5

120

200

1,9

2,00

7,5

125

210

2

2,00

7,5

90

135

1,45

1,90

7,5

Page 15: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

UNICARTA SUPERCEPI Code: 52Denominazione / Denomination: UNIS

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

CARTITALIA Srl - Via Motte, 50 - 44026 Mesola (FE)Tel. +39 0533 99 35 71 - Fax +39 0533 99 35 66 - [email protected]

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 120 127 140 150 UNI 6440

CMT 30 - Avarange value N +/- 7% 230 260 300 330 ISO 7263

CCT 30 - Avarange value KN/m +/- 7% 1,80 1,90 2,20 2,40TAPPI TT824-84

RCT CD - Avarange value KN/m +/- 7% 0,90 1,00 1,57 1,30TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 7% 2,20 2,30 2,45 2,60TAPPI826-86

Umidità - Moisture % +/- 1% 8 8 8 8 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 145 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

Page 16: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

USO SEMICHIMICACEPI Code: 44Denominazione / Denomination: US1

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 120 127 140 150 175 UNI 6440

CMT 30 - Avarange value N +/- 5% 220 240 260 285 315 ISO 2758

CCT 30 - Avarange value KN/m +/- 5% 1,60 1,85 2,05 2,15 2,80TAPPI TT824-84

RCT CD - Avarange value KN/m +/- 5% 0,85 0,95 1,15 1,25 1,85TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 5% 2,10 2,30 2,40 2,50 2,80TAPPI826-86

Umidità - Moisture % +/- 1% 8 8 8 8 8 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 145 Valido da / Valid from : 01/01/2019

CARTITALIA Srl - Via Motte, 50 - 44026 Mesola (FE)Tel. +39 0533 99 35 71 - Fax +39 0533 99 35 66 - [email protected]

Page 17: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

USO SEMICHIMICA SUPERCEPI Code: 45Denominazione / Denomination: USS

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

CARTITALIA Srl - Via Motte, 50 - 44026 Mesola (FE)Tel. +39 0533 99 35 71 - Fax +39 0533 99 35 66 - [email protected]

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% 120 127 140 150 UNI 6440

CMT 30 - Avarange value N +/- 7% 230 260 300 330 ISO 7263

CCT 30 - Avarange value KN/m +/- 7% 1,80 1,90 2,20 2,40TAPPI TT824-84

RCT CD - Avarange value KN/m +/- 7% 0,90 1,00 1,57 1,30TAPPI STAND.

T822

SCT CD - Avarange value KN/m +/- 7% 2,20 2,30 2,45 2,60TAPPI826-86

Umidità - Moisture % +/- 1% 8 8 8 8 TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 145 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

Page 18: CARBO KRAFT - Pro-Gest...SPECIFICHE TECNICHE TYPICAL CHARACTERISTICS CARBO KRAFT CEPI Code: 90 Denominazione / Denomination: CK Campioni prelevati secondo norma EN-ISO 186 condizionati

SPECIFICHE TECNICHETYPICAL CHARACTERISTICS

WELLENSTOFFCEPI Code: 60-41Denominazione / Denomination: WS

Campioni prelevati secondo norma EN-ISO 186 condizionati in laboratorio a 23°+/- 1°C ed una U.R. 50 +/- 2% secondo norma EN-ISO 187Samples taken according to norm EN-ISO 186, laboratory conditioned at 23 +/- 1 °C and 50 +/- 2% R.H. according to norm EN-ISO 187

TEST UNIT RANGE GSM STANDARD

Grammatura - Basis Weight gr/m2 +/- 3% UNI 6440

CMT 30 - Avarange value N +/- 5% ISO 7263

SCT CD - Avarange value KN/m +/- 5%TAPPI826-86

Umidità - Moisture % +/- 1% TAPPI 412-83

Diametro Bobina - Reel Diameter 127 > 150 Valido da / Valid from : 01/01/2019

VALORI NOMINALI / NOMINAL VALUES

CARTIERE VILLA LAGARINA Srl - Via A. Pesenti, 1 - 38060 Villa Lagarina (TN)Tel. +39 0464 411 511 - Fax +39 0464 410 400 - [email protected]

80

115

1,15

7,5

85

125

1,35

7,5

90

135

1,45

7,5

100

155

1,6

7,5

110

175

1,75

7,5

125

210

2

7,5