LV-ACB - Low Voltage Automatic Capacitor Banks
Low Voltage Automatic Capacitor Banksfor Improving Power Factor, ReducingTransformer Loads and Power FactorPenalties
NEPSIs low voltage automatic capacitorbanks are designed for industrial andcommercial power systems requiring a singlepoint source of power factor correction at thelow voltage level.
Product Benefits
Automatically controlled power factor
regulation.
System wide correction with a single
piece of equipment.
Low installation cost.Figure 1 - Typical Inside and Outside View
of LV-ACBTM
Product Features
System is designed with Aerovox 3-terminal ICS capacitors and are rated for conversion to a
harmonic filter.
Compact modular design with provisions for future expansion in the field.
Programmable digital power factor controller with control up to 15 steps.
Standard reactive power ratings from 150 kvar to 1000 kvar at 480 and 600 volts (75 kvar to 300
kvar at 240 volts). Higher ratings available upon request.
Indoor/Outdoor Design as standard
Automatic C/K Calibration
UL Listed as Industrial Control Panel (508A)
Multi-Ratio Split-Core Current Transformer Supplied as standard.
Short lead times.
Application
NEPSIs low voltage automatic capacitor banks are designed for low voltage systems requiring automatic
power factor correction, reduced system capacity, and improved voltage regulation. The simple modulardesign allows for future expansion as plant loads increase. The capacitors and system topology is designedfor direct conversion into harmonic filters, if the need should ever arise. Installation and startup is simpleand free of common problems.
Specification
NEPSIs low voltage automatic capacitor banks are designed to endure the harsh electrical andenvironmental conditions that are typically found in industrial process facilities.
Enclosure
NEPSIs automatic capacitor banks are housed in an enclosure with NEMA 1 construction (3R can beprovided as an option) and is suitably supported, constructed, and assembled to meet the strength and
rigidity requirements given in ANSI/IEEE C37 and UL Standards. All fastening hardware inside and out isstainless steel. To maximize corrosion resistance, the outside of the enclosure is coated with an ANSI 61light gray marine epoxy finish.
The front of the enclosure is equipped with a hinged door for easy access. The doors are mounted on
Capacitor Banks For Low Voltage Systems Requiring Automatic Power ... http://www.nepsi.com/lvacb.htm
1 of 5 7/9/2012 11:42 PM
stainless steel hinges and are held shut with 3-point latching handles. The handles are stainless steel and arelockable.
Capacitor supports and enclosure base consists of welded C4 structural steel channel. Four removablelifting eyes are provided.
CapacitorsThe capacitor bank consists of UL Listed, low loss, three bushing, industrial rated, metallized electrode,self-healing capacitors with integral discharge resistors mounted in a single steel tank. The capacitors arefinished with a UL listed ANSI #61 light-gray finish and meet or exceed the latest applicable ANSI andIEEE standards.
The capacitors have a proven 20-year (continuous duty) life expectancy. The capacitors steel case iswelded and hermetically sealed with an internal pressure interrupter, virtually eliminating the possibility ofcase rupture.
The capacitors are designed for harmonic filter bank duty and can be utilized in a harmonic filter bankretrofit, if required.
Discharge Resistors: Each capacitor cell incorporates internal discharge resistors designed to reduce thecapacitor voltage to 50 volts or less within one minute after removal from the circuit.
Environmental Parameters: Capacitors are designed to operate between
-40C and +46C (-40F to +115F).
Contactors
Each step of the LV-ACB is switched with a NEMA rated 600 Volt contactor that is UL listed for
capacitor switching. The contacts, coils, and auxiliary contacts can be changed without disturbing othercomponents within the bank.
Power Factor Controller
The LV-ACB is controlled by a digital power controller with the following features:
Automatic self adjustment to any capacitor step value
Digital indication of power factor, preset parameters and specified installation data
No-Volt release feature to immediately disconnect all capacitors in the event of a power failure.
Facility to connect mini-printer
Plug-in terminal connection
Automatic elimination of defective capacitor steps, and their indication (i.e. Welded contacts, failed
capacitor, etc.)
Visual display of target power factor alarm
Visual display of harmonic overload alarm
Protection
NEPSIs capacitor banks are equipped with overload and short circuit protection. Protection features are as
follows:
Fusing: Each stage is protected from overloads (resulting from resonance) and faults by 600 volt 200,000AIC (amps interrupting current), UL rated, bus mounted fuses. Fuses are located on the line side of the
capacitors and contactors.
Blown Fuse Lights: Each fuse is equipped with a blown fuse light that indicates a fuse operation. Lights
are mounted on the outside of the enclosure.
Warranty
12 month system warranty
Optional Accessories
Main Disconnecting Devices: (MC___) or (FD___) NEPSIs automatic capacitor banks may beequipped with either a main disconnect, main fusible disconnect, or a molded case circuit breaker that
is externally operated through a rotary handle.
Capacitor Banks For Low Voltage Systems Requiring Automatic Power ... http://www.nepsi.com/lvacb.htm
2 of 5 7/9/2012 11:42 PM
On/Off/Auto Switches: (H) On/Off/Auto Switches may be added to NEPSIs standard automatic banks toprovide complete individual control of each capacitor bank stage.
Dust Proofing: (D) Can be provided where location require filtering over louvers.
Cooling Fan: (CF) A cooling fan can be provided that increases the cooling when installed in places where
accessive heat may cause problems. Not recommended if ambient temperature does not exceed 90oF.
Out of KVAR Alarm: (KA or KL) An out of kvar alarm can be provide to give visual and/or audibleindication of not having the capability to meet the target power factor.
Ammeter: (A) A three-phase ammeter can be provided to show the operating current of each filter bankstage.
Voltmeters: (V) A three-phase voltmeter can be provided to show the system voltage.
Keyed Interlock System: (KK) A keyed interlock system can be provided that will prevent access into thecapacitor bank until the bank has been shut down by an upstream disconnecting device.
Outdoor Rating: (O) The enclosure and control panel can be designed for outdoor application.
240 Volt Automatic Capacitor Bank Selection Chart
BANK RATED SHIPPINGRATING STEP X MODEL CURRENT WEIGHT
(KVAR) KVAR NUMBER (AMPS) (POUNDS)
75 3 X 25 75LVA240F2B 181 800
100 4 X 25 100LVA240F2B 241 870
125 5 X 25 125LVA240F2B 301 940
150 6 X 25 150LVA240F2B 361 1005
200 8 X 25 200LVA240F2B 482 1140
250 10 X 25 250LVA240F2B 602 1275
300 6 X 50 300LVA240F2B 723 1410
Consult the factory or your sales representative for capacitor bank kvar ratings greater
than those or different than those shown in the table above.
480 & 600 Volt Automatic Capacitor Bank Selection Chart
BANK RATED RATED SHIPPING
RATING STEP X 480 VOLT CURRENT 600 VOLT CURRENT WEIGHT(KVAR) KVAR MODEL NUMBER (AMPS) MODEL NUMBER (AMPS) (POUNDS)
150 3 X 50 150LVA480F2B 181 150LVA600F2B 145 825
200 4 X 50 200LVA480F2B 241 200LVA600F2B 193 900
250 5 X 50 250LVA480F2B 301 250LVA600F2B 241 975
300 3 X 100 300LVA480F2B100 361 300LVA600F2B100 289 1050
300 6 X 50 300LVA480F2B 361 300LVA600F2B 289 1100
350 7 X 50 350LVA480F2B 421 350LVA600F2B 337 1125
400 4 X 100 400LVA480F2B100 482 400LVA480F2B100 385 1200
400 8 X 50 400LVA480F2B 482 400LVA600F2B 385 1250
450 9 X 50 450LVA480F2B 542 450LVA600F2B 433 1275
500 5 X 100 500LVA480F2B100 602 500LVA600F2B100 482 1350
500 10 X 50 500LVA480F2B 602 500LVA600F2B 482 1350550 11 X 50 550LVA480F2B 662 550LVA600F2B 530 1425
600 6 X 100 600LVA480F2B100 723 600LVA600F2B100 578 1500600 12 X 50 600LVA480F2B 723 600LVA600F2B 578 1550
650 13 X 50 650LVA480F2B 783 650LVA600F2B 626 1575700 7 X 100 700LVA480F2B100 843 700LVA600F2B100 674 1650
700 14 X 50 700LVA480F2B 843 700LVA600F2B 674 1700750 15 X 50 750LVA480F2B 903 750LVA600F2B 723 1725
800 8 X 100 800LVA480F2B100 963 800LVA600F2B100 771 1800800 16 X 50 800LVA480F2B 963 800LVA600F2B 771 1835
850 17 X 50 850LVA480F2B 1020 850LVA600F2B 819 1855
900 9 X 100 900LVA480F2B100 1080 900LVA600F2B100 867 1875
900 18 X 50 900LVA480F2B 1080 900LVA600F2B 867 1910
950 19 X 50 950LVA480F2B 1140 950LVA600F2B 914 1950
1000 10 X 1000 1000LVA480F2B100 1200 1000LVA600F2B100 963 1975
Consult the factory or your sales representative for capacitor bank kvar ratings greater than those ordifferent than those shown in the table above.
Capacitor Banks For Low Voltage Systems Requiring Automatic Power ... http://www.nepsi.com/lvacb.htm
3 of 5 7/9/2012 11:42 PM
Automatic Capacitor Bank Accessories
AccessoryDESCRIPTION Code
ADDITIONAL CURRENTTRANSFORMER
CT
MOLDED CASE/INSULATED CASECIRCUIT BREAKERS
250 AMP MC250
400 AMP MC400
600 AMP MC600800 AMP MC800
1000 AMP MC1000
1200 AMP MC1200
1600 AMP MC16002000 AMP MC2000
FUSED DISCONNECT SWITCH200 AMP FD200
400 AMP FD400
600 AMP FD600
800 AMP FD800
ON/OFF/AUTO SWITCHES H
OUT OF KVAR LIGHT KL
OUT OF KVAR ALARM KA
AMMETER A
VOLTMETER V
DUST PROOFING D
COOLING FAN CF
HF REACTOR RETROFIT (ADD 6 TO
WIDTH DIMENSION)
RR
KEY INTERLOCK KK
OUTDOOR RATING O
Capacitor Banks For Low Voltage Systems Requiring Automatic Power ... http://www.nepsi.com/lvacb.htm
4 of 5 7/9/2012 11:42 PM
Three-line diagram of typical low voltage automatic capacitor bank. Capacitors, transient inrush reactors,
control power transformer, contactors, 3 phase fusing, current transformer placement and incoming breaker
are shown.
Northeast Power Systems, Inc.
66 Carey Road
Queensbury, New York 12804Phone: 518-792-4776
Fax: 518-792-5767
Email: [email protected]
Website: www.nepsi.com
Copyright 1999 - 2009 Northeast Power Systems, Inc.
Capacitor Banks For Low Voltage Systems Requiring Automatic Power ... http://www.nepsi.com/lvacb.htm
5 of 5 7/9/2012 11:42 PM