  • Campus Network Infrastructure Bangladesh University of Professionals(BUP) Prepared By: Mazharul Islam Tuhin
  • Slide 2
  • Slide 3
  • Network Cabling System Basic campus Network Design Optical Fiber Backbone Campus Network Requirement Data Center Disaster Recovery Network Cabling System Basic campus Network Design Optical Fiber Backbone Campus Network Requirement Data Center Disaster Recovery
  • Slide 4
  • Slide 5
  • Existing Applications & Server
  • Slide 6
  • 1. Online Admission 2. Student Registration 3. Student portal 4. Faculty portal 5. Examination Control System Existing Applications cont..
  • Slide 7
  • 6. e-library 7. Digital Archive 8. Hall Management 9. Medical Management 10. Vehicle Management 11. Office Management Existing Applications
  • Slide 8
  • Existing Servers
  • Slide 9
  • Online Admission
  • Slide 10
  • e-Library
  • Slide 11
  • Digital Archiving
  • Slide 12
  • Result Publication system
  • Slide 13
  • Convocation Registration
  • Slide 14
  • e-Mail Server
  • Slide 15
  • BUP Internet Network
  • Slide 16
  • LAN Admin Building Academic Building Extension Building
  • Slide 17
  • SMS Based Admission Server Gateway Server PABX and IP exchange Database ServerBackup Server .. More Servers
  • Slide 18
  • Users need to be connected with each-other
  • Slide 19
  • Proposed VPN Dhaka Cantt. Chtg. Cantt. ICT Centre, BUP Jessore Cantt. Mirpur Cantt.
  • Slide 20
  • Specific VPN BMA BUP AFMCAC&S BNA BAFA PROYASH
  • Slide 21
  • Army WAN Connectivity
  • Slide 22
  • BdREN Connectivity
  • Slide 23
  • Slide 24
  • Slide 25
  • Short Description of the Proposed Network The Upper layer of the network includes internet router and firewall which provides an optimized and reliable transport structure by forwarding secured traffic at very high speeds This network has designed as fast, secured and reliable which is divided into two switching layers. Distribution Layer Access Layer The distribution layer of the network separates the access layer from the rest of the network. Departmental or workgroup access Broadcast/multicast domain definition VLAN routing Security, in the form of Access Lists and filtering The access layer is the point at which local end users are allowed into the network. Supplies traffic to the network Performs network entry control End users access network resources by way of the access layer.
  • Slide 26
  • Short Description of the Proposed Network To manage all the wireless access point under the entire network infrastructure a Wireless LAN Controller has used which is not only for central management but also have some additional features. Interference detection and avoidance Load balancing Coverage hole detection and correction QoS Management Roaming Capabilities
  • Slide 27
  • Secured Server Network (DMZ) Web servers, Mail, DNS Server are placed under the Firewalls DMZ zone. Only the specific ports of the services were partially opened for the external network by the Firewall for securing the servers and applications and also protects from any external attacks.
  • Slide 28
  • Distribution Layer Fiber Layout In this network the connectivity between the distribution and access switches will be fiber optic connection as this not only enable data traffic over longer distances, but are also more resilient to outdoor weather conditions and electromagnetic interference (EMI) Distribution Switch Access Switch Optical Fiber Link
  • Slide 29
  • Why we use Fiber Optic Cables between buildings? Greater bandwidth Fiber provides far greater bandwidth than copper and has standardized performance up to 10 Gbps Low attenuation and greater distance Because the fiber optic signal is made of light, very little signal loss occurs during transmission, and data can move at higher speeds and greater distances. Fiber does not have the distance limitation of unshielded twisted pair copper Fiber distances can range from 300 m to 40 km. Security Data is safe with fiber cable. It doesnt radiate signals and is extremely difficult to tap. Immunity and reliability Fiber provides extremely reliable data transmission. Its completely immune to many environmental factors that affect copper cable.
  • Slide 30
  • BUP Campus
  • Slide 31
  • Data Center Plancont.. DCIM Heat Load Raised floor False ceiling Racks Dimensions Steps User Cluster Backup plan Redundancy Scalability Security Fire fighting Cooling Cabling Aisle
  • Slide 32
  • Data Center Plancont.. BUILDING Location Number of floors Room size Generator room Electricity conditions Ceiling height
  • Slide 33
  • Data Center Plancont.. RACKS Dimensions Perforation ratio Cabinets Blanking panels ACCESS CONTROL Manual or Automatic Bio metric or smart card
  • Slide 34
  • Data Center Plancont.. CHILLER Capacity Compressor COOLING TECHNOLOGIES Rack cooling Row cooling Geometric Humidifier
  • Slide 35
  • Data Center Plancont.. RAISED FLOOR Materials Panel thickness Ramp Cooling flow from below Seismic kits FIRE SUPPRESSION SOLUTIONS Nozzles Extinguisher tubes suppression agent Dimensions
  • Slide 36
  • Data Center Plancont.. ENVIRONMENTAL MONITORING SYSTEM Room/Rack based Sensors Camera Alerts Mail PDU SOLUTIONS Switching Phase Monitoring
  • Slide 37
  • Data Center Plan UPS SOLUTIONS Redundancy Autonomy GENERATOR Canopy SNMP ATS STS