Busbar Systems 160...800 A
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 2/35
KO-II
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 3/35
Compact Busbar Distribution System800...6300 A
Plug-in Busbar Distribution System160...800A
Small Power Plug-in Busbar Distribution System100-160-225A
Plug-in Busbar Distribution System40-63A
Multi-Conductor Lighting Busbar System25-32-40A
Lighting Busbar System25-32-40A
Multi Conductor Trolley Busbar System
35...250A
Underfloor Ducting Systems
Raised Floor Energy Distribution Systems25...63A
CableTray Systems
E-LINE KB
E-LINE KO
E-LINE MK
E-LINE KAP
E-LINE DL
E-LINE KAM
E-LINE TB
E-LINE DK
E-LINE DKY
E-LINE UK
Compact Busbar Distribution System630...6300 A
E-LINE KX
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 4/35
ME 04
ISO9001
14001
N TAL E M M A N N O A R G I E V M N
E E N
D T
N S A
Y Y S T
I T L E A M U S Q
Catalogue 13-Eng. / 05 1000 Pcs 21/10/2013
EAE has full right to make any revisions or changes on this catalogue without any prior notice. ATA LTD. / F.A./ www.atamatbaa.net
www.eae.com.tr
EAE Elektrik A.Ş. Akcaburgaz Mahallesi,
119. Sokak, No:10 34510Esenyurt-Istanbul-TURKEY
Tel: +90 (212) 866 20 00
Fax: +90 (212) 886 24 20
T EIEC 60439-2 s
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 5/35
Introduction
Design
Order Code System
Technical Characteristics
Standard Components
Elbows
Standard Components
Feeder Boxes
Selection Of Feeder Boxes
Panel Connections
Tap-off Boxes
Fixing Elements
Vertical and Horizontal Busbar Applications
Expansion Modules Application
Fire Barrier
Determination of Special Length
Installation of End Closer
Mounting Instructions for Joints
EC Declaration Of Conformity
Certificates
Product Overview
Project Design Form
E L E K T R İ K
E-LINE KO-II
CONTENTS
2-3
4
5
6
7
8-11
12-13
14-15
16
17
18-20
21-22
23-24
25
26
26
27
27
28
29
30
31-32
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 6/35
5 5 N m
2
-E KOLINE
Introduction
E-Line KO- Busbar System distributes electrical power,
both vertically and horizontally at premises where there
is a need for electrical power 160 A and 800 A.
It provides a prefabricated and flexible electrical
distribution system for all factories engaged in massproduction, like automobile plants, textile plants,
furniture factories and for buildings where there is a
need for a reliable power supply such as business centres,
hotels, hospitals, warehouses and
all high rise buildings.
Modern Appearance
Other than its functional advantages E-Line KO-
busbar system also creates a modern appearance in
buildings where it is used.
Lower Life Cycle Cost
Busbar components can be added, removed or
relocated after the initial installation, saving time
and money.
Tap-off PointsPower can only be supplied by E-Line KO- tap-off boxes. Where necessary the unused tap-off points canbe restricted by sealing. Dust covers protect the systemfrom any accidental contact and also prevents the ingress
of pollutants from the environment.
Fast, Flexible Engineering
The large number tap-off points makes it possible to
engineer the power supply systems at an early stage,
even before the final distribution of loads is known.
Fast and Easy MountingPower is easily supplied to machines by E-Line KO- .
The installation of the system does not require any
expertise. Supports and accessories are available for
mounting the system either from the ceiling or the wall.
Safe Power Distribution and Transportation
E-Line Busbar Systems increase personnel safety
by their special features.
Lower Total Installed Cost
Total Busbar material and installation costs are often
equal to or less than cable and conduit .
Flexible Power Supply
Tap-off points at short intervals make electrical power
available in all locations, the power supply can be
adapted to different production processes simply
by relocating the tap-off units.
Being built up of basic elements, it can at any time
be extended, modified, dismantled and re-used.
Conductors
- Copper and Aluminium conductors are tin plated
along their length.
- Cross-section of neutral conductor is the same as
the phase conductors.
- Upon request the KO- range can also be
manufactured with 5 conductors.
Safe Power Take Off
The earth of the tap-off box makes contact with
the busbar first and ensures the safety, of the
box andthe system that’s been fed.
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 7/35
a= ......
a= ......
a= ......
a= ......
a= ......
a= ......
a= ......
a= ......
a= ......
a= ......
a= ......
a= ......
a= ......
a= ......
h = . . . . . .
h = . . . . . .
h = . . . . . .
h = . . . . . .
h = . . . . . .
h =
. . . . . .
h = . . . . . .
h = . . . . . .
h = . . . . . .
h = . . . . . .
h = . . . . . .
h = . . . . . .
h = . . . . . .
P
P
P
P
P
PP
PP
P
P
P
P
P
14
13
12
11
10
9
8
7
6
5
4
3
2
1
4
A
B
-E KOLINE
1. Basement
2. Basement
Ground Floor
3. Basement
While designing an electrical distribution
system with E-Line KO- a few approximate
details will be necessary.
Location, number, type and approximate
ratings of loads,
Transformer rates and short-circuit capacities, Utilization factor = a System co-ordination with other distribution
systems (heat, water, etc.)
Determining the route of E-Line KO- on layouts,
Deciding on suitable supports,
If necessary, co-ordination of E-Line KB
and E-Line MK-KAP with E-Line KO- runs.
Rated Current
The current is calculated using the following
equation.
Busbar Current rating is chosen as equal to or
higher then the calculated I current.
After the voltage drop calculation if the chosen
current rating is too low, a higher rating
should be selected.
Applications
Diversity Factor (a)
B
B
P.a
Ö3.U.cos jI =
BI
P
U
= Operating Current (A)
= Installed Load (W)
= Utilization Factor
= Supply Voltage
Location and dimensions of the shaft
where busbar will be installed,
Number, height and ceiling thickness of each storey,
Connected load for each storey,
Supply type to the vertical line (Busbar or Cable).
(h=)
(a=)
(p=)
The diversity factor(a) depends on the type and number of loads.
It is usually around 0.7 or lower. The diversity factor of a line
supplying electric motors and lighting systems is usually 0.6 It is
as low as 0.5 in welding shops of car factories,
(a) can be 1 in lines where only one big load is supplied.
As each building’s structure is different from another for
vertical and horizontal applications special projects have to be
designed.
The details on this page briefly explain the necessary
information required for designing a vertical application project.
The details below should be sent to our Project and Design
Department for Pre-Project design and cost analysis.
Vertical Distribution
Pre-Project Design and cost Analysis
a
Design
T a p - o f f P o i n t
Fire
Barrie
r
Plug-İn Tap-off Box ( H ) H e i g h t o f s t o r e y m e a s u r e d f r o m c
e i l i n g ( m m )
( a ) Ceili
ng
Thickness
(mm)
1. Plug-in Point
3. Plug-in Point
S p e c i a l L e n g t h B u s b a r
S t a n d a r d L e n g t h B u s b a r
E x p a n s i o n U n i t
2.Floor
3.Floor
4.Floor
9.Floor
8.Floor
7.Floor
6.Floor
5.Floor
10.Floor
End Of Line
Figure 1
Vertic
al
Supp
ort
Vertic
al
Supp
ort
1.Floor
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 8/35
KO A 06 5 B5 - - - DDT
IP 55 5
-B
160
250
315
400
500
600
250
315
400
600
800
01
02
03
04
05
06
02
03
04
06
08
6x20
6x25
6x30
6x50
6x62,5
6x75
6x20
6x25
6x30
6x50
6x75
L1 L2 L3 N
45
6
7
9
5
-E KOLINE
Aluminium ACopper C
UNPAINTED
PAINTED
Busbar Type
Conductor Type
Busbar Code
Protection Degree
Paint
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
Busbar
Rated Current
A l u m i n i u m
C o p p e r
Busbar
Code
CodePE
½
PECPE
½CPE
PE(Housing)
Number of
Conductors
Conductor Configuration
Configuration
4 wire5 wire
4 ½ wire
5 wire (CPE)
4 ½ wire (CPE)
Order Code System
Plug-in Standard LengthPlug-in Special LengthFeeder Standard LengthFeeder Special Length
Right ElbowLeft ElbowDownwards ElbowUpwards Elbow
Right Upwards CombinedLeft Upwards CombinedRight Downwards CombinedLeft Downwards CombinedUpwards Right CombinedUpwards Left CombinedDownwards Right CombinedDownwards Left Combined
Upwards Vertical OffsetDownwards Vertical OffsetRight Horizontal Offset
Left Horizontal Offset
“T” ComponentCrossReductions
End CloserHorizontal Expansion
Vertical ExpansionFlexible
Feeder Box 1Feeder Box 2Central Feeder Box 1
Central Feeder Box 2
Panel ConnectionsPanel Connections
STD X FTDFX
RLA
Y
KRUKLUKRDKLDKURKULKDRKDL
UV DV RH
LH
TDRD
S YDTDDTF
B1B2BO1
BO2
P10P11
Components
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 9/35
mm²
mm²
kg/m
kg/m
mm²
mmxmm
mm²
V
V
Ue
Ui
mW /m
mW /m
kA
Icw
kA
Icw
kA
Ipk
kA
Ipk
W/m1²3I R
kA
Ipk
AIn
kA
rmsIcw
20 mW /m
mW /m
mW /m
R
mW /m
f Hz
IP
01 02 03 04 05 06
120 150 180 300 375 450
120 150 180 300 375 450
7,0 7,5 8,0 10,0 11,0 12,0
7,3 8,0 8,7 11,0 12,0 13,0
583 593 603 643 668 693
60 75 90 150 187,5 225
1000
6x20 6x25 6x30 6x50 6x62,5 6x75
10,2 15,3 15,3 36 36 44,1
10,2 15,3 15,3 36 36 44,1
6 9 9 18 18 21
6 9 9 18 18 21
23,58 48,75 64,05 62,08 84,41 104,68
10 15 15 30 30 35
160 250 315 400 500 600
17 30 30 63,5 63,5 73,5
0,242
0,286
0,205
0,193
0,246
0,183
0,161
0,204
0,165
0,097
0,125
0,118
0,077
0,109
0,103
0,064
0,094
0,088
0,333
0,965
1,100
0,319
0,901
1,030
0,270
0,847
0,961
0,182
0,614
0,825
0,157
0,572
0,709
0,135
0,516
0,687
1000
50 / 60
55
0302 04 06 08
150120 180 300 450
11,010,0 12,5 16,0 18,0
12,511,0 14,0 19,0 21,0
593583 603 643 693
7560 90 150 225
6x256x20 6x30 6x50 6x75
0,2350,254
0,954
1,042
0,915
0,959
0,207
0,793
0,911
0,144
0,597
0,779
0,110
0,453
0,691
50,3335,36 70,92 86,19 133,56
150120 180 300 450
10,810,8 15 21 21
10,810,8 15 21 21
21,621,6 30 44,1 44,1
21,621,6 30 44,1 44,1
0,1540,173 0,144 0,117 0,083
3636 52,5 73,5 73,5
315250 400 600 800
1818 25 35 35
0,1200,150 0,100 0,060 0,040
0,1640,180 0,144 0,078 0,068
-E KOLINE
IEC 60439-2
1R
1X
1Z
0-ph-N
0-ph-PE
Z
Z
L
S I
S
DU
L
I
R1X1
Cosj
DU= Ö3.L.I.(R .Cosj+X .Sinj) 1011-3
V
S
L1, L2, L3, N
Power loss at rated current
Measures For Protection Against Electric Shock
PHASE CONDUCTORS
Zero empedance at 20°C
Zero empedance at 20°C(Housing)
(1)Fault condition ;
Measurements and calculations of fault-loop circuit is done according to EN 60439-2 appendix N2a.
= Supply Point
Aluminium Conductor (KOA) Copper Conductor (KOC)
Technical Characteristics
Rated Current
Standards
Busbar Code
Rated Operational Voltage
Rated Insulation Voltage
Rated Frequency
Protection Degree
Rated Short-time WithstandCurrent (1 sec)
Rated Short-timewithstand Current (N)
Rated Short-timeWithstand Current (PE)
Rated Peak WithstandCurrent (N)
Rated Peak WithstandCurrent (PE)
Rated Peak WithstandCurrent
The Mean Ohmic Resistanceat 20°C and at In
Mean Ohmic Resistance at the Steady
State Operation Temp. (q1) and at In Mean Ohmic Reactance at the SteadyState Operation Temp. (q1) and at In Mean Ohmic Impedance at the SteadyState Operation Temp. (q1) and at In
Pollution Degree
Housing Material
PE (for 5 conductors)
Weight - 4 Conductors
Weight - 5 Conductors
Housing Cross Section (Steel Sheet)
PE (for 4 ½ conductors)
Conductor Size
SECTIONS
Voltage Drop Calculation
Generally Voltage drop of a busbar system can becalculated with the following formula.
= Voltage Drop (V)
= Load Distribution Constant
= Line Length (m)= Line Current (A)
= Resistance (mW /m)
= Inductive Reactance (mW /m)
= Load Factor
Basic protection (HD 60364-4-41,clause A1)
Pregalvanized sheet metal or epoxy polyester painted pregalvanized sheet metal RAL 7038
(1)
6
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 10/35
(A) (A)mm
(A)mm
180
L1
L2
L3
N
PE
-707580-
100125
707580
100112
125-
160250315400500
600800
625 500
500375 500 500
3000
500 625
500 500 500 375
3000
X
X
7
3000
-E KOLINE
L1L2
L3NPE
L1L2
L3NPE
L1
L2L3
NPE
STD
FTD
KO - - -
-
-
L1
L2
L3NPE
X
FX
Current Aluminium Copper
Please call us for non-standard components.
Busbar cross-section dimensions
Electrical Power up to 400A can be suppliedfrom the busbar by Tap-off boxes.
E-Line KO- Busbar is manufactured in 3mlengths as standard, special lengths can bemanufactured on request.
Plug-inStandard Length
Standard Components
FeederStandard Length
Minimum special length that canbe manufactured is 350 mm.
X SpecialStraight Length
(mm)
X SpecialStraight Length
(mm)
Plug-inSpecial Straight Length
FeederSpecial Straight Length
Sample Order:250 A, Aluminium, Plug-in,IP 55, 4 Conductors
KOA 0254- -STD
Sample Order:400 A, Copper, Plug-in,IP 55, 850 mm. 5 Conductors
KOC 0455- -85
Sample Order:315 A, Aluminium, Feeder,IP 55, 5 Conductors
KOA 0355- -FTD
Sample Order:160 A, Aluminium, Feeder,IP 55, 600 mm, 4 Conductors
KOA 0154- -60
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 11/35
KOA 0254 - - R
KOC 0655 - - L
KOA 0454 - - A
KOC 0655 - - Y
R
L
A
Y
L1
L1
L1
L1
L2
L2
L2
L2
L3
L3
L3
L3
N
N
N
N
PE
PE
PE
PE
KO - - -
-E KOLINE
160250315400500600
250
315400600800
180185190210222235
180
185190210235
145147150160166172
145
147150160172
200200200200200200
200
200200200200
290290290290290290
290
290290290290
A B C D
Please call us for non-standard components.
Sample Order:
250 A, Aluminium, IP 55, 4 Conductors
Sample Order:600 A, Copper, IP 55, 5 Conductors
Sample Order:
400 A, Aluminium, IP 55, 4 Conductors
Sample Order:600 A, Copper, IP 55, 5 Conductors
Left Elbow
Downwards Elbow
Upwards ElbowCurrent
A l u m i n i u m
C o p p e r
Elbows
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
Right Elbow
8
B
A
B
A
C
D
C
D
A B
A
B
C D
D
C
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 12/35
C D
Y
Y
B
A
C
D
B A
X
A
B
AB
X
L1
L2
L3NPE
L1
L2L3
NPE
L1
L2
L3NPE
L1
L2L3
NPE
UV
DV
RH
LH
KOA 0254 - - UV
KOC 0455 - - DV
KOA 0355 - - RH
KOA 0154 - - LH
9
-E KOLINE
KO - - -
160250315400500600
250
315400600800
180185190210222235
180
185190210235
145147150160166172
145
147150160172
200200200200200200
200
200200200200
290290290290290290
290
290290290290
A B C D
Right HorizontalOffset
Left HorizontalOffset
Upwards VerticalOffset
Downwards Vertical Offset
Sample Order:
315 A, Aluminium, IP 55,
5 Conductors
Sample Order:
160 A, Aluminium, IP 55,
4 Conductors
Current
A l u m i n i u m
C o p p e r
Please call us for non-standard components.
Sample Order:
250 A, Aluminium, IP 55,4 Conductors
X= min. 200 mm.
Sample Order:400 A, Copper, IP 55,
5 Conductors
Y= min. 150 mm.
X= min. 200 mm.
Y= min. 150 mm.
Elbows
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 13/35
L1
L2
L3NPE
L1
L2L3
NPE
L1
L2
L3NPE
L1
L2L3
NPE
Y
B
A
X
X
Y
B A
B A
B
A
KRU
KLU
KRD
KLD
KOA 0254 - - KRU
KOC 0455 - - KLU
KOA 0355 - - KRD
KOA 0154 - - KLD
10
KO - - -
-E KOLINE
160250315400500600
250
315400600800
180185190210222235
180
185190210235
145147150160166172
145
147150160172
200200200200200200
200
200200200200
290290290290290290
290
290290290290
A B C D
Right DownwardsCombined Offset
Left DownwardsCombined Offset
Right UpwardsCombined Offset
Left UpwardsCombined Offset
Sample Order:
250 A, Aluminium, IP 55,
4 Conductors
Sample Order:
400 A, Copper, IP 55,
5 Conductors
Sample Order:
315 A, Aluminium, IP 55,
5 Conductors
Sample Order:
160 A, Aluminium, IP 55,
4 Conductors
Please call us for non-standard components.
Elbows
Y= min. 200 mm.
Y= min. 200 mm.
X= min. 200 mm.
X= min. 200 mm.
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
Current
A l u m i n i u m
C o p p e r
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 14/35
B
B
A
A
Y
Y
C
B
A
D
A
B
C
C
X
X
D
D
DC
L1
L2
L3NPE
L1
L2L3
NPE
L1
L2
L3NPE
L1
L2L3
NPE
KUR
KUL
KDR
KDL
KOA 0254 - - KUR
KOC 0455 - - KUL
KOA 0355 - - KDR
KOA 0154 - - KDL
11
KO - - -
-E KOLINE
160250315400500600
250
315400600800
180185190210222235
180
185190210235
145147150160166172
145
147150160172
200200200200200200
200
200200200200
290290290290290290
290
290290290290
A B C D
Downwards RightCombined Offset
Downwards LeftCombined Offset
Upwards RightCombined Offset
Upwards LeftCombined Offset
Sample Order:250 A, Aluminium, IP 55,
4 Conductors
Sample Order:400 A, Copper, IP 55,
5 Conductors
Sample Order:
315 A, Aluminium, IP 55,
5 Conductors
Sample Order:160 A, Aluminium, IP 55,
4 Conductors
Please call us for non-standard components.
Elbows
Y= min. 200 mm.
Y= min. 200 mm.
X= min. 200 mm.
X= min. 200 mm.
Current
A l u m i n i u m
C o p p e r
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 15/35
“T” Component
Cross
Reduction
RD
D
T
A B
160250315400500600
250
315400600800
290295300320332345
290
295300320345
145147150160166172
145
147150160172
Reduction
Is used to change the busbarcross section.
12
KO - - -
-E KOLINE
Sample Order:
250 A, Aluminium, IP 55,
4 Conductors
KOA 0254 - - T
Sample Order:
600 A, Aluminium, IP 55,
4 Conductors
KOA 0654 - - D
Sample Order:
400-250 A, Aluminium,IP 55,5 Conductors
KOA 0455 - - RD2
Reducers Table
- -
- -
-
- -
- -
-
- -
- -
-
- -
- -
- -
-
-
-
-
KOA - Al KOC - Cu
Conductor Conductor
Rated
Current
Reduced Busbar Current Reduced Busbar Current
160 250 315 400 6002 50 3 15 4 00 5 00
250 315
315 400
400 600
500 800
600
1 1
22
NOTE:
The selection of the reduction unitand the lower side protection is the
responsibility of the customer.
Please call us for non-standard components.
Current
A l u m i n i u m
C o p p e r
Standard Components
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
Rated
Current
A A
L1L2
L3NPE
640
L1
L2L3
NPE
A B
L1L2
L3
NPE
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 16/35
KOC 0255 - - S S
100
13
KO - - -
-E KOLINE
KOA 0254 - - YDT YDT
1000
L1
L2L3
NPE
KOC 0255 - - DDT DDT700
L1
L2
L3NPE
KOA 0454 - - F55 F
Z
L(mm)
Standard Components
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
Please call us for non-standard components.
* Please indicate X, Y, Z and ø measurement on order.
End Closer
Horizontal Expansion
Flexibles
Vertical Expansion
Sample Order:250 A, Copper, IP 55, 5 Conductors
Sample Order:
250 A, Aluminium, IP 55, 4 Conductors
Sample Order:400 A, Aluminium, 4 Conductors 550 mm.
Sample Order:
250 A, Copper, IP 55, 5 Conductors
End Closer
Is used to close the end of busbar run.
Horizontal Expansion
For long horizontal runs and forcrossing the building expansions.(See page no.25 for application)
Vertical Expansion
For vertical applications inmulti- storey buildings.(See page no.25 for application)
Flexibles
Are used for panel-busbarconnections.
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 17/35
B2
B1
L1
L2
L3
NPE
Y Y
X
X
X
X
D
A
B
B
C
A C D X Y B
160 550 350 350 180 85 55
550
550
350
350
350
350
180
180
85
52,5
52,5
85
550 350 350 180 85 50
550 350 350 180 85 40
550 350 350 240 85 65
550 350 350 240 85 57,5
550 350 350 180 5585
550 350 350 180 5085
550 350 350 180 4085
550 350 350 240 57,585
250
315
400
500
600
250
315
400
600
800
210
210
200
200
KOC 0255 - - B1
KOA 0254 - -B2
L1
L2
L3
NPE
KO - - -
-E KOLINE
Feeder Box sample equipped with MCCB
Please call us for special applications or for applications with MCB's
Feeder Box 1
Feeder Box 2
Current
A l u m i n i u m
C o p p e r
Sample Order:
250 A, Copper, IP 55,5 Conductors
Sample Order:
250 A, Aluminium IP 55,
4 Conductors
Feeder Boxes
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
14
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 18/35
KOA 0654 - - BO1
KOA 0654 - - BO2 BO2
BO1
600
210
210
365
365
6 0 0
L1
L1
L2
L2
L3
L3
N
N
PE
PE
230
600
210
210
6 0 0
230
15
-E KOLINE
KO - - -
3 6 5
1 4 5
2 7 0
107,5
N L3 L2 L1
PE
Central
Feeder Box BO 1
Central
Feeder Box BO 2
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
Feeder Boxes
(Central Feeder Box BO)
Please call us for special applications or for applications with MCCB's
Sample Order:
600 A, Aluminium, IP 55,4 Conductors
Sample Order:
600 A, Aluminium IP 55,
4 Conductors
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 19/3516
L 1
L 2
L 3
N P E
B1
B1
B2
B2
B2
B1
-E KOLINE
L1L2
L3NPE
1 5 0 m m .
1 5 0 m m
.
150 mm.
In vertical installation the neutralconductor should be on the right side.It is important for tap-off box connections.
Selection of Feeder Boxes
Application of
Tap-off Boxes for
Horizontal Lines
Application of Tap-off Boxesfor Vertical Lines
FRONT
In horizontal installation the neutralconductor is situated as shown above.
Ceiling
Wall
2. Plug-in Point1. Plug-in Point
S p e c i a l L e n g t h B u s b a r
V e r t i c a l E x p a n s i o n
S t a n d a r d L e n g t h B u s b a r
Fire
Barrie
r
Vertic
al
Suppo
rt
Ceiling
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 20/35
L1 L2
L3N PE
2 0 0
4 1
0
KOA 0655 - - P11
KOA 0655 - - P10
A A
A
A
y y
y y
x
x x
øz
øz øz
øz
t
160250315400500600
250315400600800
2025305062,575
2025305075
404040404040
4040404040
202020202020
2020202020
91111
13,513,513,5
91111
13,513,5
-----
40
----
40
122334
12234
x y z t
KO - - -
-E KOLINE
70707065
180
2 6 0 2
1 0
50 4 1 0
1 5
1 5
1 0 0
1 0 0 1
5 0
400
145
460
145 15140
P11
P10
L1 L2
L3N PE
2 0 0
4 1
0
A
Panel Connections
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
CONDUCTOR CONFIGURATION
UNPAINTED / PAINTED
COMPONENT
Figure 1 Figure 2
Figure 3 Figure 4
Busbar Feeder
Panel Feeder
Sample Order:600 A, Aluminium, IP 55, 5 Conductor
Sample Order:600 A, Aluminium, IP 55, 5 Conductor
Panel Feeder
Busbar Feeder
A
l u m i n i u m
C o p p e r
Current Figure
Panel ConnectionPlate
E-Line KO-Busbar
Note: 230x460mm flange plate
dimensions are standard forall busbar types.
Opening on the panel board
PanelConnectionPlate
Please call us for non-standard components.
1 5 0 ± 3
17
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 21/35
KOP 1651-S
KOP 2551-S
KOP 4051-S
A
B
B
B
A
A
-E KOLINE
L1L2L3N
L1L2L3N
L1L2L3N
A30 30
5 0
KOP 160
KOP 250
KOP 400
A mm A
B mm
C mm
RP2
RP3
RPK1370
480
625
300
380
380
195
245
255
49795
49797
95053
NH 00
NH 1
NH 3
KYA
KYA
SYK
Please call us for non-standard components.
KO
BUSBAR TYPE
BOX TYPE
BOX RATINGPROTECTIONDEGREE
FUSEDSWITCHES TYPE
IP 55 5
S- STANDARD SYK
B- EMPTY
15P
160 A - 16250 A - 25
400 A - 40
Cable Gland Plates
Tap-Off Boxeswith Fused Switches (SYK)
Mat.Cable
Gland TypeOrderCode
InnerDiameter
(mm)SheetMetal
RP0----
SheetMetal
RP1 25M32
M40SheetMetal
RP2 32
SheetMetal
RP3 63Special
AL RP4 632xSpecial
RP5 18
RP6 25
RP7 32
RP8 25
AL 4xM25
AL 4xM32
AL 4xM40
AL 8xM32
Fused Switches (SYK)
Tap-off boxes are equipped withEAE syk fused switches that;
Can operate under load, Are equipped with NH fuse holders, Have Interlock mechanism Padlock applicable
Tap-off boxes can be equipped withother brand of fused switches on request.
Tap-off boxes are painted in redas standard.Continuous current of tap-off boxeswith fused switch should not exceed 80% of tap-off box current rating.
Gland Plate
s
(on tw
o sides)
Gland
Plates
(on th
ree si
des)
Gland
Plates
(on th
ree si
des)
CURRENT CableGland
5W
Order No.
Fused
Switches
FuseSize
18
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 22/35
KOP 1651-B1KOP 1651-M1
KOP 4051-B1KOP 4051-M1
KOP 2551-B1KOP 2551-M1
KOP 160
KOP 250
KOP 400
A mm A
B mm
C mm
RPK3
RP3
RPK2
19
-E KOLINE
A
B
C
A30 30
A
B
C
L1L2L3N
A
B
C
L1L2L3N
L1L2L3N
5 0
420
500
675
300
300
300
220
220
220
35484
35486
35504
KO
BUSBAR TYPE
BOX TYPE
BOX RATINGPROTECTIONDEGREE
FUSEDSWITCHES TYPE
IP 55 5
15P
160 A - 16250 A - 25
400 A - 40
Cable Gland Plates
Special Cable Gland Plates
G l a
n d P l a
t e s
( o n
t h r
e e s i d
e s )
G l a n d
P l a t e s
( o n
t h r e
e s i d e
s )
G l a
n d P l a
t e s
( o n
t h r
e e s i d
e s )
Mat. CableGland Type OrderCode
InnerDiameter
(mm)
SheetMetal
RP0---- ----
SheetMetal
RP1 25M32
M40SheetMetal
RP2 32
SheetMetal
RP3 63Special
AL RP4 632xSpecial
AL RP5 184xM25
AL RP6 254xM32
AL RP7 324xM40
AL RP8 258xM32
Mat.Cable
Gland Type
SheetMetal
----
SheetMetal
M25
M32
M40
1xSpecial
SheetMetal
Sheet
Metal
SheetMetal
OrderCode
InnerDiameter
(mm)
RPK0 ----
RPK1 18
RPK2
RPK3
RPK4
25
32
63
Tap-Off Boxesfor MCCB’s
Please call us for non-standard components.
* EAE tap-off boxes can be designed for allbrands of MCCB’s.
5WOrder No.
Current Cable
Gland
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 23/35
1
KOP 0851-B1
KOP 045 -B1
KOP 0451-B2
KOP 0851-B2
KOP 0451 - B1
KOP 0451 - B2
1 3 5
1 8 1
1 0 5
2 3 0
20
1 9 0
30
330
290
2 3 0
20
1 9 0
30
330
1 4 6
1 9 2
1 0 5
290
-E KOLINE
Please call us for non-standard components.
KO 15P
BUSBAR TYPE
BOX TYPE
BOX RATINGPROTECTIONDEGREE
SWITCH TYPE
IP 55 5
B1 -Transparent hinged lid / Empty tap off box
B2 -Transparent fixed lid / Empty tap off boxW -Equipped with MCB
40 A - 04 80 A - 08
3x6 A
3x10 A3x16 A
3x20 A3x25 A
3x32 A3x40 A
3x50 A3x63 A
3x80 A
Tap-Off Boxes
Sample Order:40 A, IP 55, 5 wire, transparenthinged lid, suitable for MCB,empty tap off box
Sample Order:40 A, IP 55, 5 wire, transparentfixed lid, suitable for MCB,empty tap off box
20
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 24/35
ASU2A
KO-UT
KO-UT
KO-UT
KO-UT
L
21
-E KOLINE
40
40
L
L
4
(A) (A)mm
(A)mm
-707580-
100125
707580
100112125
-
160250315400500600800
31,5
46
2
ExtensionPart
ThreadedRod
Steel Nut
Washer
Fixing Elements
ThreadedRod
ThreadedRod
Current Aluminium Copper
EAEPull-off
Dowel
Diameter of thehole to be drilled
Busbar cross-section dimensions
UAS-K4L Support
M8.......Ø12
M10.....Ø14
Tray Supports
Tray Supports
CodeL(mm)
ASU2A-1
ASU2A-2
ASU2A-3
ASU2A-4
ASU2A-5
Description
CodeL(mm)
UAS-K4 SUPPORT (1)
UAS-K4 SUPPORT (2)
UAS-K4 SUPPORT (3)
UAS-K4 SUPPORT (4)
UAS-K4 SUPPORT (5)
UAS-K4 SUPPORT (6)
UAS-K4 SUPPORT (7)
UAS-K4 SUPPORT (8)
UAS-K4 SUPPORT (9)
Description
200
250
300
350
400
500
600
700
1100
135
250
500
1000
2000
Connection Parts
CodeL(mm)
BRA 11-05 Threaded Rod (M8)
BRA 11-10 Threaded Rod (M8)BRA 12-05 Threaded Rod (M10)
BRA 12-10 Threaded Rod (M10)
Description
500
1000500
1000
BRA 10 Extension Part (M8)
BRA 13 Extension Part (M10)
BRA 9 EAE Pull-off Dowel (M8)
BRA 9 EAE Pull-off Dowel (M10)
M8 Steel Nut
M10 Steel Nut
M8 Washer
M10 Washer
-
-
-
-
-
-
-
-
Flatwise
application sample
Flatwiseapplication sample
Edgewise
application sample
Edgewise
application sample
3005333
3005332
3005331
3005330
3005329
3005328
3005327
3005326
3005325
3008589
3008587
3008585
3008583
3008168
5000039
50000385000037
5000032
1004313
1004312
5000033
5000023
1000521
1000522
1000502
1000504
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 25/35
-E KOLINE
TMP 8
ASU2A
KT
A
TS
2 5
1 1 x
1 6
7 x 1 6
A
4
1 3 5
7,5 1 2
2 5
125155
1 0 5
Ø10
14x20
15x35
12x20
70
7 5
9 0
1 0 x 3
0
9 0
1 3 x 3 5
1 0 , 5 x 3 5
3 0
A
2 3 5
A
9 0
Ø13Ø11Ø9
Ø1010x20
42,5
35
22
Fixing Elements
Vertical Support SetWall Type
Vertical Support Set(Z) Type
Vertical Support Set(VS) Type
Code
Vertical Support Set Wall Type
Description
Code
Vertical Support Set (Z) Type
Description
CodeCurrent A(mm)
KOA - 1 UT Clamp
KOA - 2 UT Clamp
KOA - 3 UT Clamp
KOA - 4 UT Clamp
KOA - 5 UT Clamp
KOA - 6 UT Clamp
KOC - 2 UT Clamp
KOC - 4 UT Clamp
KOC - 6 UT Clamp
KOC - 8 UT Clamp
Description
160
250
315
400
500
600
250
400
600
800
115
120
125
145
157
170
115
125
145
170
Code
Vertical Support Set (VS)-40
Vertical Support Set (VS)-60
Description
A(mm)
40
60
KO-UTClamp
KT 200 Tray Support
KT 250 Tray Support
KT 300 Tray Support
KT 400 Tray Support
KT 500 Tray Support
KT 600 Tray Support
TS 200 Tray Support
TS 200 Tray Support
TS 200 Tray Support
TS 200 Tray Support
TS 200 Tray Support
TS 200 Tray Support
TMP 8 Ceiling Support Unit
Coupling
A(mm)
235
285
335
435
535
635
205
255
305
405
505
605
-
-
Coupling
CodeDescription
1004275
1004278
1004274
1004277
1004265
1004276
1004275
1004274
1004277
1004276
3025371
3025376
3025379
3025378
3008567
3008565
3008563
3008561
3008559
3008264
3008551
3008549
3008547
3008545
3008543
3005828
3008382
1004310
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 26/3523
-E KOLINE
1 0 0
100
1 0 0
1 0 0
100
100
1 0 0
5 0
BUSBAR
INTERNAL KO-II FIREBARRIER MODULE
200 (min.)
100
L1
L2
L3
NPE
L1
L1
L2
L2
L3
L3
N
N
PE
PE
L1
L2
L3
NPE
L1 L2 L3 N PE L1 L2 L3 N PE
Vertical and Horizontal Busbar Applications
SLAB
W A L L
FIGURE-1 FLATWISE POSITION
SLAB
B E A M
FIGURE-4 CROSSING UNDER A BEAM HORIZONTAL POSITION
BUSBAR (FLATWISE POSITION)
SLAB
W A L L
FIGURE-2 FLATWISE POSITION
BUSBAR-1
BUSBAR-2
SLAB
W A L L
FIGURE-3 EDGEWISE POSITION
BUSBAR-1 BUSBAR-2
The dimensions given above are minumum values .
W A L L
JOINT POINT
HOLE
FIGURE-6 STANDARD WALL CROSSING
BUSBAR
W A L L
HOLE
FIGURE-5 SAMPLE WALL CROSSING WITH FIRE BARRIER
EXTERNAL FIRE BARRIERMATERIAL
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 27/3524
-E KOLINE
2 0
FRONT WALL
200 1
0 0
1 3 0
C
B
150
2 0 0
2 0 0
A
B
C
A= B+C+330
= Min distance from front wall
= Distance to open the cover of Tap off box
= Depth of Tap off box
L1
L1L1
L1L2
L2L2
L2L3
L3L3
L3N
NN
NPE
PEPE
PE
Application of Tap off
box on vertical lines
Neutral conductor position inhousing should be on rightsidefrom front view at vertical lines.
FRONT
L1 L2 L3 N PE
B + 1 0 0
A
Vertical and Horizontal Busbar Applications
SLAB
B E A M
FIGURE-7 CROSSING UNDER A BEAM EDGEWISE POSITION
BUSBAR (EDGEWISE POSITION)
BACK WALL - CURTAIN CONCRETE
W A L L
BOXES
FIGURE-8 MINIMUM DIMENSIONS BETWEEN 2 TAP-OFF BOXES
TAP-OFFBOXES
TAP-OFF
S L A B
FIGURE-9MINIMUM DIMENSIONS ON SHAFT APPLICATIONS
V E
R T I C A L E X P A N S I O N
C O
M P O N E N T
P L U G - I N B U S B A R
S L A B
W A L L
All dimensions are given in mm.The dimensions given above are minumum values .
NOTE : To determine the busbar layout
in correct shaft measurement
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 28/3525
-E KOLINE
BL=39m
BL=40-60m
BL>51m
BL>78m
B
B
L>60m
L<39m L<39m L<39m L<39m
FIXED
HANGER
FIXEDHANGER
2 0 0 m m
2 0 0
m m
B U S B A R
Horizontal And Vertical Expansion Modules Application
Horizontal expansion module ( YDT ) application
Vertical expansion modüle (DDT) application
It is used for longer horizontal runs as per the pictures shown below (Picture-1)
It is essential that a YDT is used if busbar runs cross a building expansion joint
Feeding point
Line end
Expansion module
1-) DDT is used for vertical lines of multistorey buildings .
2-) DDT is used between two fixed supports at every floor crossing.
150cm
BUILDING EXPANSION
FIGURE-3 DDT APPLICATION
FIGURE-2 YDT BUILDING EXPANSION APPLICATION
FIGURE-1 YDT APPLICATION
S L A B
S L A B
V E R T I C A L
E X P A N S I O N
C O M P O N E N T
W A L L
B E A M
B E A M
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 29/35
-E KOLINE
26
Fire Barriers
Fire barriers are used to prevent the transition of flame and smokefrom one zone to another in case of fire. The fire barriers prevent thechimney effect of air insulated busbar.
Dimensioning of Fire Barrier
When placing an order for fire barriers to be installed in the KO- busbar,the following information is required :
1- Thickness of floor or wall in cm. (A mm)
2- Centreline dimension of the fire barrier should be measured from the sidewithout the block joint. (Y mm)
3- There will be no plug-in points at the fire barrier location.
4- EAE Supplies a 300 mm thick fire barrier as standard when wall or floorthickness is not stated.
5- 0 mThe minimum length for these special elements with fire barrier is 60 m.
FloorSample Order:250 A, Copper, IP 55, 5 ConductorsFire Barrier
KOC 0255- -STD-150-40InternalFireBarrier
Block Joint
Please call us for more information.
Fire Barriers
After the installation of standard 3m lengths, special lengths shorter than 3m may be required.
The minimum length for these special lengths is 350 mm. Please measure these special lengths as shown below.
Determination of Special Lengths
A
A (mm): Thickness of Fire Barrier Y (mm): Centreline of Fire Barrier
KO B
BUSBAR TYPE
CONDUCOR TYPE
BUSBAR CODE
PROTECTION DEGREE
NUMBER OF CONDUCTORS
UNPAINTED / PAINTED
COMPONENT
Y DIMENSION
A DIMENSION
Measure “A” length in cm, to determine the length of
special busbar subtract 12 from “A”.
X=A-120 (mm) X=Length of Special Busbar
Fire B
arrie
r
1
2
A
Y
External fireresistance sealantby customer
N
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 30/3527
-E KOLINE
3
8
55 Nm (40lbft)
7
65
21
2a
1a
1a
4
1
4
2
1
2
3
4
5 1
2
3
4
3
1
2
3
4
6
1- Remove joint top cover plate, joint sidecover plate and the screws from non-block
joint bolt. (Pieces marked as 1a should be
thrown away.)
2- Introduce bolted and non-bolted ends ofthe busbar into each other carefully, until the
cover plate screws can be put in.
3- Fix the joint side cover of the block joint.
4- Tighten the double headed
nut untill upper nut is broken.
7- Ensure that the insulationplates of the joint, are notcrackedor broken.
8- If removal is required for any reason,tighten the nut using a calibrated torque
wrench adjusted to 55 Nm (40 lbft) after
re-fitting the block joint set.
6- Install top and bottom joint cover plates. Check the joint
before fitting the last joint side cover plate. Fit the joint coverside plate and tighten the screws. Check the position of theearth conductor when installing KO-II with five conductors.
5- Take away the broken nut
and plastic seperator.
Figure 3
KO- Installation of End Closer
KO- Mounting instructions for Joints
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 31/35
E L E K T R İ K
EAE Elektrik A.Ş.Date
30.12.2006
-E KOLINEDeclaration
CE DECLARATION OF CONFORMITY
Product Group
Standard :
Manufacturer
E-Line KO-II Busbar Energy Distribution System
IEC 60439-1
IEC 60439-2
EAE Elektrik Asansor End. Insaat San. ve Tic. A.S.
EAE Elektrik Asansor End. Insaat San. ve Tic. A.S.
This is to attest, under our sole responsibility, that the aforementioned products conforms with
the determined regulations,guidelines and the below standards.
CE - Directive
2006/95/EC “Low Voltage Directive”
Akcaburgaz Mahallesi, 119. Sokak, No:10 34510 Esenyurt-IstanbulTel: +90 (212) 866 20 00 Fax: +90 (212) 886 24 20 www.eae.com.tr
Akcaburgaz Mahallesi, 119. Sokak,No:10 34510 Esenyurt-Istanbul
Type Tests include verification of;
1- Temperature-rise Limits (8.2.1)
2- Dielectric Properties (8.2.2)
3- Short-circuit Strength (8.2.3)
4- The Effectiveness of The Protective
Circuit (8.2.4)5- Clearances and Creepage Distances (8.2.5)
6- Mechanical Operation (8.2.6)
7- Degree of Protection (8.2.7)
8- The Resistance of Insulating Materials to
Abnormal Heat and Fire (8.2.9)
9- Structural Strength (8.2.10)
10- Crushing Resistance (8.2.12)
11- Resistance of Insulating Materialsto Abnormal Heat (8.2.13)
12- Resistance to Flame Propagation (8.2.14)
13- Fire Resistance in Building
Penetration (8.2.15)
28
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 32/3529
-E KOLINE
Certificates
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 33/35
-E KOLINE
Product Overview
160A 800A BUSBAR SYSTEM
PRODUCT OVERVIEW (E-LINE KO-II)
Standards & Certification:- Busbar system shall be designed and manufactured as per IEC 60439-2 standard. Each individual rated busbar shall have separate type test certificate from an independentinternationally accredited laboratory.
-- Busbar system shall have CE marking.- Each product shall have a “Type Label”, which indicates the brand, type of the unit, conductor number and electrical details.
Manufacturing facility of busbar systems shall have ISO 9001 and ISO 14001 certification.
Joint Structure:- Electrical and mechanical connection shall be made at joints by “single bolt” joint construction and each joint shall have two “Belleville” washers.- Insulators of the joint shall be manufactured of glass-reinforced polyester.- Joints shall be realized by a torque spanner (wrench) set at 55 Nm.
- To prevent the joints from transportation damages, they shall be protected by metal caps, which shall be removed before installation.- Joint bolt shall be locked from both sides (Bolt head and nut).
Tap Off Boxes:- Rating of plug-in tap off boxes shall be up to and including 400A. Plug-in tap off boxes shall be installed, when the busbar line is energized.- Tap off boxes shall have an electrical interlock mechanism, which ensures that plug-in tap off box cannot be removed mechanically from the busbar, when the switch is at “ON”position. Mechanical interlock mechanism shall prevent the cover of the box from opening, when the switch is at “ON” position.- When the switch is at “OFF” position and the cover is open, tap off box shall provide IP2X protection level. (There shall not be any accessible live part in the box).- Tap Off boxes shall be suitable for any brand of MCB.- Contacts of plug-in tap off box shall be silver-plated copper.- While inserting the contacts of Plug-in tap off boxes, earth contact shall make first contact.- Tap off boxes up to 80A shall be manufactured of (850 GLW) type plastic material. Tap off boxes from 160A up to 400A shall be manufactured of sheet steel and epoxy painted
RAL 3020.
Installation and Commissioning:- Busbar systems shall be installed as per single-Line drawings respect to required ampere rates and manufacturer installation guide (torque values, lockers, etc.).Electrical installer shall run an insulation test after installation according to manufacturer's test procedures. The results of the test shall be reported to the manufacturer.Minimum insulation value shall be 1Mohm.
Housing and Structure:- Busbar system shall be of air insulated type. The bars shall be supported by insulators installed into the housing at every 25 cm.- On a three meter standard length busbar the distance between the plug-in points on one side shall be 50cms. The points shall be on both sides of the busbar making theaverage distance of plug-in points 25cm.- To prevent wrong alignment of the phase sequence during installation there shall be mechanical barriers on the joint that shall ensure correct mounting.- IP Plug-in covers of the busbar system should be hinged.Plug-in windows shall have automatic shutter system. This shutter shall open automatically when the earth contact oftap-off box is inserted.- Busbar system shall have all necessary accessories (elbows, offsets, panel-transformer connections, reductions, etc). Manufacturer shall supply special dimensioned units inshort time, if the project conditions requires.- For horizontal runs, a horizontal expansion unit shall be used at every 40m and expansion points of the building.- For vertical applications, a vertical expansion unit shall be used at every floor. Busbar system shall be rigidly fixed by supports at every floor.
General Structure of Products:- Busbar system shall be Air-Insulated and Plug-in type. Aluminium or Copper conductors shall be tin plated along the entire length. Housing shall be galvanized steel or if requiredRAL 7038-Electrostatic painted.
Electrical Characteristics:- Busbar systems nominal insulation voltage shall be 1000V.- As per ampere rates, minimum short circuit values shall be like below;- Temperature rise shall be maximum 50K over 40°C ambient temperaturefor both tin plated Aluminium and Copper conductor busbars.
Conductors:- Busbar system shall have Nickel and Tin-plated 6101 class aluminium conductors (160-600A). / Busbar system shall have Tin-plated Electrolytic copper conductors (250-800A).- Busbar system shall have below number of conductors and phase configuration;
a) 4 Conductors:(4 full size conductors + Housing ( earthing )b) 4 ½ Conductors :(4 full size conductors + ½ earth conductor + Housing)c) 5 Conductors :( 5 full size conductors + Housing (earthing) )d) 5 Conductors :( 5 full size conductors, 5th bar shall be used as clean earth + Housing).
- Neutral conductor shall have the same cross-section (100%) of phase conductors.
Insulation:- Busbars shall have air-insulation system.- Rated insulation voltage of the system shall be 1000 V.
Protection:- Protection degree of the busbar system shall be minimum IP55.
1-
2-
2.1-
2.2-
2.3-
2.4-
2.5-
2.6-
3-
4-
1sec/rms-10kA, Peak-17kA1sec/rms-15kA, Peak-30kA1sec/rms-30kA, Peak-63kA1sec/rms-35kA, Peak-73,5kA
160A:250 and 315A:400 and 500A:
600A and above:
30
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 34/3531
E L E K T R İ K
-E KOLINE
Q u a n t i t y
C o m p o n e n t
C o m p o n e n t L i s t
I t e m
Project Design Form
P l e a s e d u p l i c a
t e
t h i s p a g e f o r y o u r o w n u s e .
N a m e
:
D a t e
:
S i g n a t u r e :
P r e p a r e d b y C o m p a n y
:
P r o j e c t
:
P r o j e c t N o
:
7/26/2019 Bus Bar -Good Article
http://slidepdf.com/reader/full/bus-bar-good-article 35/35
E L E K T R İ K
-E KOLINE
Q u a n t i t y
C o m p o n e n t
C o m p o n e n t L i s t
I t e m
Project Design Form
P l e a s e
d u p
l i c a
t e t h i s p a g e
f o r y o u r o w n u s e .
N a m e
:
D a t e
:
S i g n a t u r e :
P r e p a r e d b y C o m p a n y
:
P r o j e c t
:
P r o j e c t N o
: