Benefits

• Designed to replace HPS bulbs in outdoor luminaires

• Optimizedforcolorandefficacy

• Long lifetime with a strong return on investment

• Uniform lighting patterns designed for targeted applications

• Improvedthermalmanagement

• Simplifiedrobustluminairedesignandassembly

• Improvedinventorymanagementandqualitycontrol

Introduction

BridgeluxOLM™Seriesmodulesenableasimpleandeasywaytodevelopoutdoorluminaires.Themodulesdeliverhighquality,

energyefficientlightingforcommercial,industrial,andexteriorapplications.Designedforrapidproductdevelopmentand

integration,OLMmodulesmechanicallyattachwithfourscrews.Soldering,glues,andepoxiesareremovedfromtheassembly

processandreplacedwitharobustelectricalconnection.Theintegrationofopticsandenvironmentalprotectionfurthersimplify

luminairedesign.

OLMmodulescontainIP66ratedprotectionandproprietaryopticstoenablethelonglifeandstableperformancerequired

fromluminairesusedinoutdoorlighting.OLMSeriesmodulesleveragetheseventhgenerationVero®Seriesproductfamily,the

latestgenerationofBridgeluxLEDarrays,todeliverlumenoutputlevelstoreplacehighpressuresodium(HPS)andmetalhalide

technologiesusedinoutdoorluminaires.

Features

• Typicalefficacyofupto156lm/Wat70°C

• Typicallumenoutputrangesfrom1600to4600lumens

• BroadrangeofCCToptionsfrom4000Kto5700K

• Minimum70,80CRIoptionsavailable

• Asymmetricandsymmetriclightingpatterns

• IP66ratedforreliableoutdooruse

• High level of component integration

OL

M S

erie

s

Page 3: Bridgelux® OLM™ Series

3

Contents

Product Feature Map 4

Product Nomenclature 4

Product Selection Guide 5

ElectricalCharacteristics 6

AbsoluteMaximumRatings 7

PerformanceCurves 8

OpticalCharacteristics 9

Mechanical Dimensions 10

DesignResources 11

Precautions 11

Disclaimers 11

About Bridgelux 12

Page 4: Bridgelux® OLM™ Series

4

Product Feature Map

OLMincorporatesseveralfeaturestosimplifythedesignintegrationandmanufacturingprocess,acceleratetimetomarketandreducesystemcosts.PleaseconsulttheBridgeluxOLMSerieswebpageatwww.bridgelux.comformoreinformation.

Product Nomenclature

ThepartnumberdesignationforBridgeluxOLMSeriesisexplainedasfollows:

1234-5678910-11121314-1516171819

Product Family Internal Code

Minimum CRIC=70CRIE=80CRI

Nominal CCT40=4,000K50=5,000K57=5,700K

OLMB – 40 E 000 – A – 02A AA000

Internal Code

Optical OrientationA=AsymmetricS=Symmetric

Optical PatternSeecharacterizationsinTable5

2D Bar code provides full

manufacturing traceability

Tc Measurement point

located directly under the array

Aluminum mounting plate

adds stability and thermal

spreading

Mechanical mounting holes

Electrical connection wire harness

IP66 rated protection from water and dust

Proprietary asymmetric and symmetric optics

Pressure vent allows moisture and gas removal during thermal cycling

Page 5: Bridgelux® OLM™ Series

5

Product Selection Guide

Thefollowingproductconfigurationsareavailable:

Table 1: Selection Guide

NotesforTable1:

1. Bridgeluxmaintainsatoleranceof±0.20VonforwardvoltageforOLMmodules.

2. TestedinpulsedconditionsatTc =25°C.Pulsewidthis10ms.3. Bridgeluxmaintainsa±10%toleranceonfluxvaluesforOLMmodules.

4. TypicalperformancewhendrivenunderDC(directcurrent)withOLMmodulecasetemperature(Tc) maintainedat70°C.OLMmoduleismountedtoaheatsinkwiththermalinterfacematerial..Valuesmayvarydependingonthethermaldesignoftheluminaireand/ortheexposedenvironmenttowhichtheproductissubjected.

5. TypicalstabilizedDCperformancevaluesareprovidedasreferenceonlyandarenotaguaranteeofperformance.

Part NumberNominal CCT (K)

CRIDrive

Current (mA)

Typical Vf1

Tc = 25ºC (V)

Typical Power

Tc = 25ºC (W)

Typical Pulsed Flux2,3

Tc = 25ºC(lm)

Typical Efficacy Tc = 25°C(lm/W)

Typical DC Flux4,5

Tc = 70ºC(lm)

Typical Efficacy Tc = 70°C(lm/W)

OLMB-40C000-xxxx-xx000 4000 70

500 21.9 11.0 1802 164 1676 154

750 22.7 17.0 2649 156 2463 146

900 23.1 20.8 3139 151 2918 142

1500 24.4 36.6 4968 136 4619 127

1800 24.8 44.7 5803 130 5395 122

OLMB-40E000-xxxx-xx000 4000 80

500 21.9 11.0 1659 151 1542 142

750 22.7 17.0 2438 143 2266 135

900 23.1 20.8 2889 139 2686 131

1500 24.4 36.6 4572 125 4251 117

1800 24.8 44.7 5341 119 4966 112

OLMB-50C000-xxxx-xx000 5000 70

500 21.9 11.0 1818 166 1691 156

750 22.7 17.0 2672 157 2484 148

900 23.1 20.8 3167 152 2944 143

1500 24.4 36.6 5012 137 4660 129

1800 24.8 44.7 5855 131 5443 123

OLMB-57C000-xxxx-xx000 5700 70

500 21.9 11.0 1755 160 1631 150

750 22.7 17.0 2578 152 2397 142

900 23.1 20.8 3056 147 2841 138

1500 24.4 36.6 4836 132 4496 124

1800 24.8 44.7 5649 126 5252 119

Page 6: Bridgelux® OLM™ Series

6

Electrical Characteristics

Table 2: ElectricalCharacteristicsandDriverSelectionVoltages

Part NumberDrive Current

(mA)

Forward VoltagePulsed, Tc = 25º C (V) 1, 2, 3 Typical Coeffi-

cient of Forward Voltage4 ∆Vf/∆T

(mV/º C)

Typical Thermal Resistance

Array case to Module case

(º C/W)

Driver Selection Voltages5

(V)

Minimum Typical Maximum Vf Min. Hot

Tc = 105º C (V)

Vf Max. Cold Tc = -40º C (V)

OLMB-xxx000-xxxx-xx000

900 21.4 23.1 24.9 -5.4 0.42 21.0 25.2

1800 23.0 24.9 26.7 -5.4 0.48 22.6 27.1

NotesforTable2:

1. Partsaretestedinpulsedconditions,Tc=25°C.Pulsewidthis10ms.

2. Voltageminimumandmaximumareprovidedforreferenceonlyandarenotaguaranteeofperformance.

3. Bridgeluxmaintainsatoleranceof±0.20VonforwardvoltageforOLMmodules.

4. Typicalcoefficientofforwardvoltagetoleranceis±0.1mV.

5. Vfminhotandmaxcoldvaluesareprovidedasreferenceonlyandarenotguaranteed.Thesevaluesareprovidedtoaidindriverdesignandselectionovertheoper-atingrangeoftheproduct.

Page 7: Bridgelux® OLM™ Series

7

Absolute Maximum Ratings

Table 3:MaximumDriveCurrentandReverseVoltageRatings

Parameter Maximum Rating

StorageTemperature -40°Cto+55°C

AmbientTemperature(Ta) 55°C

OperatingModuleCaseTemperature(Tc) 70°C

MaximumDriveCurrent1,2 1800mA

MaximumPeakPulsedDriveCurrent3 2580mA

MaximumReverseVoltage4 -20V

NotesforTable3:

1. Lumenmaintenance(L70)andlifetimepredictionsarevalidfordrivecurrentandcasetemperatureconditionsusedforLM-80testingasincludedintheapplicableLM-80testreportforthesearrays.ContactyourBridgeluxsalesrepresentativesforLM-80report.

2. OLMmodulesmaybedrivenathighercurrents.However,lumenmaintenancemaybereduced.

3. Bridgeluxrecommendsamaximumdutycycleof10%andpulsewidthof20mswhenoperatingOLMmodulesatmaximumpeakpulsedcurrentspecified.MaximumpeakpulsedcurrentsindicatevalueswhereLEDArrayscanbedrivenwithoutcatastrophicfailures.

4. OLMmodulesarenotdesignedtobedriveninreversevoltageandwillnotproducelightunderthiscondition.Maximumratingprovidedforreferenceonly.

Page 8: Bridgelux® OLM™ Series

8

Performance Curves

Figure 3: Typical DC ccy Shift vs. Case Temperature

0%

25%

50%

75%

100%

125%

150%

175%

200%

0 300 600 900 1200 1500 1800

Re

lati

ve

Flu

x

Drive Current (mA)

90%

92%

94%

96%

98%

100%

102%

0 10 20 30 40 50 60 70 80

Re

lati

ve

Flu

x

Case Temperature (°C)

Figure 1: Typical Relative Luminous Flux vs. Drive Current (Tc = 25°C)

NotesforFigure1.

1. TestedinpulsedconditionsatTc =25°C.Pulsewidthis10ms.

Figure 2: Typical DC Flux vs. Case Temperature

-0.0080

-0.0070

-0.0060

-0.0050

-0.0040

-0.0030

-0.0020

-0.0010

0.00000 10 20 30 40 50 60 70 80

cc

y S

hif

t

Case Temperature (°C)

25° C pulsed

5000 K, 70 CRI

-0.0050

-0.0045

-0.0040

-0.0035

-0.0030

-0.0025

-0.0020

-0.0015

-0.0010

-0.0005

0.00000 10 20 30 40 50 60 70 80

cc

x S

hif

t

Case Temperature (°C)

25° C Pulsed

5000 K, 70 CRI

Figure 4: Typical DC ccx Shift vs. Case Temperature

Page 9: Bridgelux® OLM™ Series

9

Optical Code DescriptionIES

ClassificationNEMA

ClassificationEN 13-201Guidance

A01A Asymmetric;Narrow,ShortWidth TypeII,Med 7Hx7V ME2-ME4

A06A Asymmetric;Medium,ShortWidth TypeIII,Short 7Hx7V ME2-ME4

Table 4: Optical Pattern Descriptions

Figure 5: Photometric Performance (Optical Code: A01A)

Figure 6: Photometric Performance (Optical Code: A06A)

Optical Characteristics

Page 10: Bridgelux® OLM™ Series

10

Figure 7: Mechanical Dimensions

NotesforFigure7:

1. Mountingholes(4x)accommodateM4or#8screws.

2. Screwswithflatshoulders(pan,dome,button,round,truss,mushroom)provideoptimaltorquecontrol.DoNOTuseflat,countersink,orraisedheadscrews.

3. Drawingdimensionsareinmillimeters.

4. Unlessotherwisespecified,tolerancesare±1.00mm.

5. RefertoApplicationNoteAN61forproducthandling,mountingandheatsinkrecommendations.

Mechanical Dimensions

Page 11: Bridgelux® OLM™ Series

11

Application Notes

Bridgelux has developed a comprehensive set of application notes and design resources to assist customersinsuccessfullydesigningwiththeOLMmodules.Foralistofresourcesunderdevelopment,visitwww.bridgelux.com.

Optical Files

Farfieldopticalfilesareavailablein.IESand.LDTformat.Con-tactyourBridgeluxsalesrepresentativefordetails.Pleaseuseappropriateprecautions.ItisimportantthatusersworkingwithLEDsaretrainedtousethemsafely.

MINOR PRODUCT CHANGE POLICY

TherigorousqualificationtestingonproductsofferedbyBridgeluxprovidesperformanceassurance.Slightcosmeticchangesthatdonotaffectform,fit,orfunctionmayoccurasBridgeluxcontinuesproductoptimization.

CAUTION: CHEMICAL EXPOSURE HAZARD

Exposuretosomechemicalscommonlyusedin luminairemanufacturingandassemblycancause damagetotheLEDarray.PleaseconsultBridgelux ApplicationNoteAN61foradditionalinformation.

CAUTION: EYE SAFETY

PleasecontactyourBridgeluxsalesrepresentativeforEyesafetyclassificationandIECspecifications.

3D CAD Models

ThreedimensionalCADmodelsdepictingtheproductoutlineareavailableinbothIGSandSTPformats.PleasecontactyourBridgeluxsalesrepresentativeforassis-tance.

CAUTION

CONTACT WITH OPTICAL AREA

TheOLMismanufacturedwithmoldedpolycarbonatelenses.Thelensisextremelydurable,butnotindestruc-tible.Excessiveforceonthelensmaycausedamagetothemodule.

CAUTION: RISK OF BURN

Donottouchthemodulelensduringoperation.Allowthemoduletocoolforasufficientperiodoftimebeforehandling.

Design Resources

Precautions

Disclaimers

Page 12: Bridgelux® OLM™ Series

12

About Bridgelux: We Build Light That Transforms

©2016Bridgelux,Inc.Allrightsreserved.Productspecificationsaresubjecttochangewithoutnotice.BridgeluxandtheBridgeluxstylizedlogodesignareregisteredtrademarks,OLMSeriesisatrademarkofBridgelux,Inc.Allothertrademarksarethepropertyoftheirrespectiveowners.

Bridgelux OLM Series Product Data Sheet DS60 Rev. C (11/2016)

101 Portola Avenue

Livermore, CA 94551

Tel (925) 583-8400

www.bridgelux.com

AtBridgelux,wehelpcompanies,industriesandpeopleexperiencethepowerandpossibilityoflight.Since2002,we’vedesignedLEDsolutionsthatarehighperforming,energyefficient,costeffectiveandeasytointegrate.Ourfocusisonlight’simpactonhumanbehavior,deliveringproductsthatcreatebetterenvironments,experiencesandreturns—bothexperientialandfinancial.Andourpatentedtechnologydrivesnewplatformsforcommercialandindustrialluminaires.

For more information about the company, please visit bridgelux.comtwitter.com/Bridgeluxfacebook.com/Bridgeluxhttps://www.linkedin.com/company/bridgelux-inc-_2WeChat ID: BridgeluxInChina