Blood Pressure Measurement Does it matter where you do it or how often? James (Jim) M. Wright Coordinating Editor Cochrane Hypertension Group

Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Blood Pressure Measurement Does it matter where you do it or how

often?

James (Jim) M. Wright Coordinating Editor Cochrane Hypertension Group

Page 2: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Conflict of Interest

  First half – evidence based, no conflicts.   Second half – opinion based, potential

conflict.   VSM Med Tech Ltd, Vancouver, BC.   Studies to compare BP TRU machine with

ausculatory measurements.   Two free machines.   No free lunches.

Page 3: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Outline

  Clinical setting.   Evidence-based.   Diagnosis and treatment.   Variability of blood pressure.   Office based vs. home based.   Ambulatory   Pragmatic – What do I do?   Conclusions

Page 4: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Blood pressure measurement

Evidence-based half

Page 5: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Clinical Setting

  Screening, emergency, etc.   Position, method, etc. not critical.   Slap, lub-dub method is satisfactory.

  Diagnosis and treatment decisions:   Must use evidence-based methodology from

RCTs proving benefit of treatment.

Page 6: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Why is this critical?

  Random BP measurements by physician are on average 10 mmHg higher than that taken by technician using appropriate method.

  What do you think the impact of this will be on number of patients diagnosed and treated and on the number of drugs prescribed?

  This assumes you are using the same arbitrary BP threshold, 140/90 mmHg.

Page 7: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Key components of evidence-based method

  RESTING FOR AT LEAST 5 MINUTES.   Quiet room, no distractions.   Comfortable chair, back supported.   Measurement by nurse or technician.   AT LEAST 2 MEASUREMENTS.   No conversation.   Proper technique.

Page 8: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded
Page 9: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

How variable are BP measurements?

  Using evidence-based methodology.   Mean ± SD for individual.   BP 140±9/ 90±6 mmHg

  What does this mean?   95% of measurements are within ± 2 SD.   Syst range 122 – 158 mmHg, Diast range 78 – 102

mmHg.   Non-resting, one BP, slap-lub-dub, etc. – variability

will be greater.

Page 10: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

How do you know whether a drug is working or not working?

  Very difficult.   Single visit (even multiple measurements) is

not sufficient to answer the question.   Multiple measurements on multiple visits are

needed to have any degree of certainty.   What will happen if every time the blood

pressure is > 140 mmHg you increase the dose or add another drug?

Page 11: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

How much does maximum dose of a BP lowering drug lower blood pressure?

  On average.   Systolic 6 – 9 mmHg.   Diastolic 3 – 6 mmHg.

Page 12: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Blood pressure measurements

Opinion-based half

Page 13: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Are home BP readings useful?

  Yes if the following conditions are present.   Machine is accurate.   Machine is automatic.   Proper technique: position, resting, multiple

measurements, etc.   Patient is objective and accurate in

recording.

Page 14: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Home BP monitors

London Drugs on-line lists over a dozen monitors ranging from about $50 to about $120 …

Page 15: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

60 yr old male patient Home recordings.

  135 single BPs: Mean ± SD, 156±13/ 84±8   Mean of 5 BPs: 156±10/ 84±5

  Pre second drug 160±7 / 86±6 mmHg, 66±4   Post second drug 152±11/ 80±6 mmHg 51±4

Page 16: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

When do I use 24 hr ambulatory measurements?

  Seldom if at all.   Represent BP during activity – Not resting.   I don’t know what to do with the large amount

of information.   Daytime, sleeping, maximum, minimum,

mean, variability, etc.

Page 17: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

What if you can’t afford a nurse or technician to measure BP?

  Try to mimic the evidence-based method, using an automatic machine.

Page 18: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Automatic machine

  Advantages   Automatic computerized device will measure

BP the same every time.   Eliminate observer variability and biases.   Measurements can be done without

physician in the room.   Saves physician time.   Relatively inexpensive.

Page 19: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Automatic machine

  Disadvantages   You don’t know how well the BP

measurements reflect the evidence-based method.

Page 20: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

One local automated BP machine

BPM-100 BP and HR, 5 readings + mean: CAD$945. BPM-300 with USB connectivity: CAD$1,195.

Page 21: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

BP TRU

  Electric.   Wall mounted.   Uses an oscillometric technique.   First measurement taken with physician in

the room; this measurement is automatically discarded.

  Five BP measurements taken with nobody in the room.

Page 22: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

BP TRU

  Time between measurements can be set from 1 to 5 minutes.

  Machine computes average of 5 and saves each measurement.

  These measurements must be manually recorded in patient’s chart.

Page 23: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Concluding questions

  Do you think that you are managing elevated BP in your patients with an evidence-based approach?

  In what ways do you think you could improve your BP measurements to make your decisions more evidence-based?

Page 24: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Suggestions

  Patient resting   Patient comfortable   Mean of multiple measurements   Reproducible technique every time   Same standards for office and home

measurements.

Page 25: Blood Pressure MeasurementBP TRU Electric. Wall mounted. Uses an oscillometric technique. First measurement taken with physician in the room; this measurement is automatically discarded

Questions??

If home BPs are different than office BPs, which do you use for treatment decisions?