17
AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

Embed Size (px)

Citation preview

Page 1: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

AS_GSV Stationsfor

Processing & Visualizationof

HR Medical ImagesExit

Course-AS1 Ltd.- Adaptive Medical Systems

Page 2: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

AS_GSV Stations General Options

2D Processing & Visualization

AS_GSV Stations Advantages

Types of AS_GSV Stations

Summary

About Course-AS1 Ltd.

Contents:

- General Elements of AS_GSV Stations

- Real Time Stream Processing

- Real Time Zoned Processing

Page 3: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

Course-AS1 Ltd.- Adaptive Medical Systems

Founded in 1993 in Moscow, Russia.

Focuses on developing new technologies and systems in the following areas:

• 2D processing for HR (High Resolution) medical images• Specialized computer systems for radiology• Multi-machine Parallel Calculations• Chips-2D for processing HR images

http://www.course-as.com

__Course-AS1 Ltd. - Adaptive Medical Systems__ Office 427B, Business Park “Rumiantsevo”, MO, G.P. Moscow, 142784, Russian Federation.

Mikael Abgaryan, Ph.D. Director

E-mail: abgaryan@course-as. com Tel/Fax: +7 (499) 550-5096 WEB: www.course-as.com +7 (499) 550-7682

www.course-as.ru (Full version)

http://www.course-as.ru

Page 4: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

Professional,Professional,High Quality and Fast High Quality and Fast

2D2DProcessing & VisualizationProcessing & Visualization

forfor HR Medical ImagesHR Medical Images

Course-AS1 Ltd.

Page 5: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

2D- Visualization

2D Processing & Visualization for HR Medical ImagesHigh-Speed Hardware/Software 2D Conveyor based on Original Mathematical Processing of entire frame or in chosen Zones consisting of:

Primary DICOM Images in Computer Memory

The 16bit Conveyor for 2D Processing

Visualization

• 2D Conveyor Hardware functions of visualization and some of processing elements in the graphic adapter (2D-Visualization)

Scenario

• Processing Scenarios - sequence of types and processing cycles with a Parameter Settings

Principle of Work 2D Processing & Visualization:

2D-Technology

• Sequence 16b software functions the 2D Software Conveyor for frame image processing (2D-Processing)

• Image Frame (DICOM Image) - the minimal part of information for 2D-Visualization and 2D-Processing Conveyor

Page 6: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

General Elements of AS_GSV Stations

• Graphical DataBase – as Graphical Patient’s History

• The Navigator for Operation with DICOM files in Graphical DataBase

• Professional 2D Processing & Visualization for DICOM Systems

PDF file

• Patient Data House and Graphical DataBase

• Preprint Processing & Viewing for printing of processed images

• Real Time Dynamic Stream 2D Processing (XA, RF) of 16b images (up to 60 fps of a format 1k*1k)

• Real Time Dynamic Stream 2D Subtraction (DSA)• of 16b images (up to 30 fps of a format 1k*1k)

• Real Time Dynamic Zoned 2D Processing of 16b series and single frames

Page 7: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

• Radiological series (RF, DF, VF, CR, RG)Slides – Screen shots of processing

Film 1 – Processing of 8b DICOM series

• Angiographic series (AS, XA, DSA)

• Tomography series (CT, MR, PT)

• Ultrasound series (US, EC, CD, DD)

Slides – Screen shots of processingFilm 1 – Primary 10b DICOM seriesFilm 2 – DICOM representation of seriesFilm 3 – Nonlinear Processing 10b DICOM of series Film 4 – DSA mode (Subtraction)

Film 1 – Viewing 3D reconstruction of device CT

Slides – Screen shots of processing

Slides – Screen shots of processing

Real Time Stream 2D Processing Series Frames (Modality) AS, XA, DSA, RF, DF, VF, CT, MR, PT, US, EC, CD, DD

Page 8: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

• Angiographic series (AS, XA, DSA)

• Radiological series (RF, DF, VF, CR, RG)

• Tomography series (CT, MR, PT)

Slides – Screen shots of processing

Film 1 – Processing in a circular zone

Film 2 – Processing in an elliptic zone

Slides – Screen shots of processing

Film 1 – Processing CT series of a human bodySlides – Screen shots of processing

Film 2 – Processing CT series of a lower jaw

Real Time Zoned 2D ProcessingSeries and Single Frames (Modality) CR, RF, RG, MG, XA, CT, MR, SC

Page 9: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

• 16b Professional Tool for qualitative improvements of medical images

PC Stations AS_GSV series for 2D Processing and Visualization of all types of DICOM files for:

• X-Ray diagnostics • Angiographic research• Computer Tomography • Nuclear-Magnetic Resonance Tomography • Ultrasonography• Other kinds of diagnostics based on DICOM images

AS_GSV Stations operations with DICOM files received from devices of different manufacturers:

AS_GSV Stations General Options

General Electric, Philips, Siemens, Picker, Kodak, Toshiba, Camtronics, InfiMed, Acuson, ATL, Hewlett-Packard ect.

Page 10: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

• Fine Quality Printing of the processed images on high resolution PC Printers without using of expensive DICOM printers

• The Authorized Access of users from any AS_GSV station connected to the Graphical DataBase for:

• visualization of DICOM primary data• independent processing of DICOM series for visualization• visualization of the series processed earlier by other users

• Interactive Visualization of the processing series for: • displays on operational and viewing monitors • displays in clinical and consultation facilities• displays at symposiums and conferences

• Recording to Optical CD / DVD :• recording on DVD-RAM in the Archive for Patient Data House• processing results and primary DICOM files

AS_GSV Stations General Options

Page 11: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

AS_GSV Stations Advantages

• Real Time Dynamic Processing of primary Angiographic series, switching to DSA mode

• Exclusive Real Time Zone Processing of single or serial frames

• Professional High Speed Visualization based on the Scenarios

• Processing always only in the 16b resolution for Gray images (65536 gradation gray)

Professional Visualization unattainable

on PACS systems

Page 12: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

High Speed and

simplicity of high quality

visualization

• Automatic creation of Processing Scenarios as a result of manipulations by users

• The Professional Intuitive 16b Real Time Tools for management & control of image processing

• Instant adjustment of conveyor processing and visualization based on created Scenarios

• Rapid response to change of processing parameters or conveyor elements

AS_GSV Stations Advantages

Page 13: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

Simplicity and

high speed navigations

• Viewing and Grouping of DICOM files in a series with subsequent import in GDB

• All operations with DICOM files are conducted under the control of Graphical DataBase (GDB)

• Adjustable Options of GDB operations and access rights of users

• Unlimited number of users at simultaneous work with the same series

AS_GSV Stations Advantages

Page 14: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

Simplicity of

realization of HIS/RIS

clinical system

Advantages of Systems based on the AS_GSV Stations

• Integration of AS_GSV Stations in PACS system as Professional Stations for 2D Processing

• Allocation of AS_GSV stations in a Network of 2D Professional Processing Images

• Scalability of Systems to include a range from one office or division up to clinical HIS/RIS

• Patient Data House volume minimization will be achieved by saving only DICOM

primary data

• AS_GSV Stations can be used as Base Stations for newly created PACS systems

Page 15: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

• Base upon a 64b hardware platform – IBM IntelliStation A-Pro

• Opportunity to modernize by adding of PCI-X Professional Graphic Adapters with HR-monitors

• Essential Cost Reduction of diagnostic workstations and PACS systems

• Easy transition to a 64b Operational System without replacement of base computers

Advantages of Systems based on the AS_GSV Stations

Total Ownership Cost (TCO)reduction of medicaldiagnosticsystems

Page 16: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

Types of AS_GSV Stations• Dual monitor AS_GSV-1k Station for dynamic frames up to 1k*1k

for angiographic, radiological and tomographic research

• Dual monitor AS_GSV-2k Station for dynamic frames up to 2k*2kfor angiographic and radiological research of the high resolution

• Dual monitor AS_GSV-4k2 Station for static frames larger than 2k*2kfor radiological research of the super high resolution

• Three monitor AS_GSV-4k3 Station for static frames lager than 2k*2kfor radiological research of the super high resolution and viewing rooms

• The Machine of AS_AVGBase DataBase (for 100-150 users)

• The Machine of AS_VRTBank - Temporary Data House(for 5-10 users or for a angiography)

1xOpteron 2.2GHz, 1GB DDR ECC Registered (up 2GB), 36GB System HDD SCSI, DVD-RW Plextor Ext, 1Gb Ethernet (up 10Gb InfiniBand), 19” RGB CRT 1600*1200*32b/(75-85)Hz, 21” RGB CRT 1600*1200*32b/(75-100)Hz for Images, Windows XP Professional & SP1, Library MIL v 5.0, Software AS_GSV-1k

2xOpteron 2.2GHz, 2GB DDR ECC Registered (up 4GB), 36GB System HDD SCSI, DVD-RW Plextor Ext, 1Gb Ethernet (up 10Gb InfiniBand), 19” RGB CRT 1600*1200*32b/(75-85)Hz, 21” RGB CRT 2048*1560*32b/(75-85)Hz for Images, Windows XP Professional & SP1, Library MIL v 5.0, Software AS_GSV- 2k

2xOpteron 2.2GHz, 2GB DDR ECC Registered (up 4GB), 36GB System HDD SCSI, DVD-RW Plextor Ext, 1Gb Ethernet (up 10Gb InfiniBand), 19” RGB CRT 1600*1200*32b/(75-85)Hz, 21” B&W CRT 2560*2048*32b/(50-75)Hz for Images, Windows XP Professional & SP1, Library MIL v 5.0, Software AS_GSV- 4k2

2xOpteron 2.2GHz, 2GB DDR ECC Registered (up 4GB), 36GB System HDD SCSI, DVD-RW Plextor Ext, 1Gb Ethernet (up 10Gb InfiniBand), 19” RGB CRT 1600*1200*32b/(75-85)Hz, 2x21” B&W CRT 2560*2048*32b/(50-75)Hz for Images, Windows XP Professional & SP1, Library MIL v 5.0, Software AS_GSV- 4k3

1xOpteron 2.2GHz, 2GB DDR ECC Registered (up 4GB), 36GB System HDD SCSI, 400GB RAID-0 SATA (up 800GB) , 1Gb Ethernet (up 10Gb InfiniBand), Windows NT 4.0 & SP6.

2xOpteron 2.2GHz, 4GB DDR ECC Registered (up 16GB), 2x36GB System HDD SCSI, 250GB SATA HDD (for Archive), 147GB RAID-1 U320 SCSI (for database), 4xDVD-RAM 9GB, DVD-RW Plextor Ext, 1Gb Ethernet (up 10Gb InfiniBand), 19” RGB CRT 1600*1200*32b/(75-85)Hz, Windows NT 4.0 & SP1, Library MIL v 5.0, Software AVGBase-2k04.

Page 17: AS_GSV Stations for Processing & Visualization of HR Medical Images Exit Course-AS1 Ltd. - Adaptive Medical Systems

Summary

Unprecedented quality of imagesfor reliable diagnostics!

Unprecedented speed of processingand visualization of medical images

Optimized Total Cost Ownership of AS_GSV Stations of a professional class

Professional Stations 2D Processing & Visualization - Perfect Tool for Professionals!

Exit

Medical images processing and visualization management simplicity