KOS-EME-08-36 (MCFV12.4 09-03-2021) KORDIA SOLUTIONS PTY LTD EBU24875 Page 1 of 3 Issued by: Kordia - IRFA, NAD (v1.0.134682.44960) Environmental EME report (v12.4 Feb 2021) Produced with RF-Map 2.1 (Build 3.2) Environmental EME Report Locaon 31-45 Great Western Highway, WENTWORTH FALLS NSW 2782 Date 21/06/2021 RFNSA No. 2782002 How does this report work? This report provides a summary of levels of radiofrequency (RF) electromagnec energy (EME) around the wireless base staon at 31-45 Great Western Highway, WENTWORTH FALLS NSW 2782. These levels have been calculated by Kordia - IRFA using methodology developed by the Australian Radiaon Protecon and Nuclear Safety Agency (ARPANSA). A document describing how to interpret this report is available at ARPANSA’s website: A Guide to the Environmental Report. A snapshot of calculated EME levels at this site The maximum EME level calculated for the exisng systems at this site is 3.98% out of 100% of the public exposure limit, 98 m from the locaon. The maximum EME level calculated for the proposed changes at this site is 8.31% out of 100% of the public exposure limit, 92 m from the locaon. EME levels with the proposed changes Distance from the site Percentage of the public exposure limit 0-50 m 4.92% 50-100 m 8.31% 100-200 m 7.79% 200-300 m 3.55% 300-400 m 2.05% 400-500 m 1.17% For addional informaon please refer to the EME ARPANSA Report annexure for this site which can be found at hp://www.rfnsa.com.au/2782002. Radio systems at the site This base staon currently has equipment for transming the services listed under the exisng configuraon. The proposal would modify the base staon to include all the services listed under the proposed configuraon. Exisng Proposed Carrier Systems Configuraon Systems Configuraon Vodafone 2G, 3G, 4G GSM900, LTE850, WCDMA900 2G, 3G, 4G, 5G GSM900, LTE700 (proposed), LTE850, WCDMA900, NB-IOT900 (proposed), LTE1800 (proposed), LTE2100 (proposed), NR3500 (proposed)

ARPANSA EME Report

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ARPANSA EME Report

KOS-EME-08-36 (MCFV12.4 09-03-2021) KORDIA SOLUTIONS PTY LTD EBU24875 Page 1 of 3

Issued by: Kordia - IRFA, NAD (v1.0.134682.44960)

Environmental EME report (v12.4 Feb 2021) Produced with RF-Map 2.1 (Build 3.2)

Environmental EME ReportLocation 31-45 Great Western Highway, WENTWORTH FALLS NSW 2782

Date 21/06/2021 RFNSA No. 2782002

How does this report work?This report provides a summary of levels of radiofrequency (RF) electromagnetic energy (EME) around the wireless

base station at 31-45 Great Western Highway, WENTWORTH FALLS NSW 2782. These levels have been calculated by

Kordia - IRFA using methodology developed by the Australian Radiation Protection and Nuclear Safety Agency

(ARPANSA).

A document describing how to interpret this report is available at ARPANSA’s website:

A Guide to the Environmental Report.

A snapshot of calculated EME levels at this siteThe maximum EME level calculated for the existing

systems at this site is

3.98%out of 100% of the public exposure limit, 98 m from the

location.

The maximum EME level calculated for the proposed

changes at this site is

8.31%out of 100% of the public exposure limit, 92 m from the

location.

EME levels with the proposed changes

Distance fromthe site

Percentage of the public exposurelimit

0-50 m 4.92%

50-100 m 8.31%

100-200 m 7.79%

200-300 m 3.55%

300-400 m 2.05%

400-500 m 1.17%

For additional information please refer to the EME ARPANSA Report annexure for this site which can be found at

http://www.rfnsa.com.au/2782002.

Radio systems at the siteThis base station currently has equipment for transmitting the services listed under the existing configuration.

The proposal would modify the base station to include all the services listed under the proposed configuration.

Existing Proposed

Carrier Systems Configuration Systems Configuration

Vodafone2G, 3G,4G

GSM900, LTE850, WCDMA9002G, 3G,4G, 5G

GSM900, LTE700 (proposed),LTE850, WCDMA900, NB-IOT900(proposed), LTE1800 (proposed),LTE2100 (proposed), NR3500

(proposed)

Page 2: ARPANSA EME Report

KOS-EME-08-36 (MCFV12.4 09-03-2021) KORDIA SOLUTIONS PTY LTD EBU24875 Page 2 of 3

Issued by: Kordia - IRFA, NAD (v1.0.134682.44960)

Environmental EME report (v12.4 Feb 2021) Produced with RF-Map 2.1 (Build 3.2)

Optus 3G, 4GWCDMA900, LTE700, LTE1800,

WCDMA2100, LTE21003G, 4G,5G

LTE700, LTE900 (proposed),WCDMA900, WCDMA2100,LTE2600 (proposed), LTE1800,

NR/LTE2100, NR3500 (proposed)

Telstra3G, 4G,5G

WCDMA850, LTE1800, LTE2100,LTE700, NR850, LTE2600, NR3500

3G, 4G,5G

WCDMA850, LTE1800, LTE2100,LTE700, NR850, LTE2600,

NR3500

Page 3: ARPANSA EME Report

KOS-EME-08-36 (MCFV12.4 09-03-2021) KORDIA SOLUTIONS PTY LTD EBU24875 Page 3 of 3

Issued by: Kordia - IRFA, NAD (v1.0.134682.44960)

Environmental EME report (v12.4 Feb 2021) Produced with RF-Map 2.1 (Build 3.2)

An in-depth look at calculated EME levels at this siteThis table provides calculations of RF EME at different distances from the base station for emissions from existing

equipment alone and for emissions from existing equipment and proposed equipment combined. All EME levels are

relative to 1.5 m above ground and all distances from the site are in 360o circular bands.

Existing configuration Proposed configuration

Distance fromthe site

Electric field(V/m)

Powerdensity(mW/m2)

Percentage ofthe publicexposurelimit

Electric field(V/m)

Powerdensity(mW/m2)

Percentage ofthe publicexposurelimit

0-50m 11.88 374.43 3.85% 13.38 474.66 4.92%

50-100m 12.00 381.95 3.98% 14.82 582.84 8.31%

100-200m 10.40 287.15 3.97% 14.74 576.09 7.79%

200-300m 6.83 123.68 1.72% 9.81 255.45 3.55%

300-400m 5.09 68.59 0.98% 7.43 146.54 2.05%

400-500m 3.83 38.82 0.56% 5.64 84.35 1.17%

Calculated EME levels at other areas of interestThis table contains calculations of the maximum EME levels at selected areas of interest, identified through

consultation requirements of the Communications Alliance Ltd Deployment Code C564:2020 or other means.

Calculations are performed over the indicated height range and include all existing and any proposed radio systems for

this site.

Maximum cumulative EME level for the proposed configuration

Location Height rangeElectric field

(V/m)

Powerdensity(mW/m2)

Percentage ofthe publicexposurelimit

Public Assess 1-3 m 11.28 337.28 3.58%

Dwelling 2 0-3 m 6.96 128.37 1.39%

Dwelling 3 0-6 m 10.15 273.07 3.67%

Dwelling 1 0-3 m 8.10 173.90 2.16%