Upload
others
View
6
Download
0
Embed Size (px)
Citation preview
KOS-EME-08-36 (MCFV12.4 09-03-2021) KORDIA SOLUTIONS PTY LTD EBU24875 Page 1 of 3
Issued by: Kordia - IRFA, NAD (v1.0.134682.44960)
Environmental EME report (v12.4 Feb 2021) Produced with RF-Map 2.1 (Build 3.2)
Environmental EME ReportLocation 31-45 Great Western Highway, WENTWORTH FALLS NSW 2782
Date 21/06/2021 RFNSA No. 2782002
How does this report work?This report provides a summary of levels of radiofrequency (RF) electromagnetic energy (EME) around the wireless
base station at 31-45 Great Western Highway, WENTWORTH FALLS NSW 2782. These levels have been calculated by
Kordia - IRFA using methodology developed by the Australian Radiation Protection and Nuclear Safety Agency
(ARPANSA).
A document describing how to interpret this report is available at ARPANSA’s website:
A Guide to the Environmental Report.
A snapshot of calculated EME levels at this siteThe maximum EME level calculated for the existing
systems at this site is
3.98%out of 100% of the public exposure limit, 98 m from the
location.
The maximum EME level calculated for the proposed
changes at this site is
8.31%out of 100% of the public exposure limit, 92 m from the
location.
EME levels with the proposed changes
Distance fromthe site
Percentage of the public exposurelimit
0-50 m 4.92%
50-100 m 8.31%
100-200 m 7.79%
200-300 m 3.55%
300-400 m 2.05%
400-500 m 1.17%
For additional information please refer to the EME ARPANSA Report annexure for this site which can be found at
http://www.rfnsa.com.au/2782002.
Radio systems at the siteThis base station currently has equipment for transmitting the services listed under the existing configuration.
The proposal would modify the base station to include all the services listed under the proposed configuration.
Existing Proposed
Carrier Systems Configuration Systems Configuration
Vodafone2G, 3G,4G
GSM900, LTE850, WCDMA9002G, 3G,4G, 5G
GSM900, LTE700 (proposed),LTE850, WCDMA900, NB-IOT900(proposed), LTE1800 (proposed),LTE2100 (proposed), NR3500
(proposed)
KOS-EME-08-36 (MCFV12.4 09-03-2021) KORDIA SOLUTIONS PTY LTD EBU24875 Page 2 of 3
Issued by: Kordia - IRFA, NAD (v1.0.134682.44960)
Environmental EME report (v12.4 Feb 2021) Produced with RF-Map 2.1 (Build 3.2)
Optus 3G, 4GWCDMA900, LTE700, LTE1800,
WCDMA2100, LTE21003G, 4G,5G
LTE700, LTE900 (proposed),WCDMA900, WCDMA2100,LTE2600 (proposed), LTE1800,
NR/LTE2100, NR3500 (proposed)
Telstra3G, 4G,5G
WCDMA850, LTE1800, LTE2100,LTE700, NR850, LTE2600, NR3500
3G, 4G,5G
WCDMA850, LTE1800, LTE2100,LTE700, NR850, LTE2600,
NR3500
KOS-EME-08-36 (MCFV12.4 09-03-2021) KORDIA SOLUTIONS PTY LTD EBU24875 Page 3 of 3
Issued by: Kordia - IRFA, NAD (v1.0.134682.44960)
Environmental EME report (v12.4 Feb 2021) Produced with RF-Map 2.1 (Build 3.2)
An in-depth look at calculated EME levels at this siteThis table provides calculations of RF EME at different distances from the base station for emissions from existing
equipment alone and for emissions from existing equipment and proposed equipment combined. All EME levels are
relative to 1.5 m above ground and all distances from the site are in 360o circular bands.
Existing configuration Proposed configuration
Distance fromthe site
Electric field(V/m)
Powerdensity(mW/m2)
Percentage ofthe publicexposurelimit
Electric field(V/m)
Powerdensity(mW/m2)
Percentage ofthe publicexposurelimit
0-50m 11.88 374.43 3.85% 13.38 474.66 4.92%
50-100m 12.00 381.95 3.98% 14.82 582.84 8.31%
100-200m 10.40 287.15 3.97% 14.74 576.09 7.79%
200-300m 6.83 123.68 1.72% 9.81 255.45 3.55%
300-400m 5.09 68.59 0.98% 7.43 146.54 2.05%
400-500m 3.83 38.82 0.56% 5.64 84.35 1.17%
Calculated EME levels at other areas of interestThis table contains calculations of the maximum EME levels at selected areas of interest, identified through
consultation requirements of the Communications Alliance Ltd Deployment Code C564:2020 or other means.
Calculations are performed over the indicated height range and include all existing and any proposed radio systems for
this site.
Maximum cumulative EME level for the proposed configuration
Location Height rangeElectric field
(V/m)
Powerdensity(mW/m2)
Percentage ofthe publicexposurelimit
Public Assess 1-3 m 11.28 337.28 3.58%
Dwelling 2 0-3 m 6.96 128.37 1.39%
Dwelling 3 0-6 m 10.15 273.07 3.67%
Dwelling 1 0-3 m 8.10 173.90 2.16%