6" SCHEDULE 40 STEEL POSTFILLED WITH CONCRETE. PAINT EXTERIOR OF POST WITH RUST-O-LASTIC ANTI-CORROSIVE PRIMER AND 2 COATS OF RUST-O-LASTIC ACRYLIC DTM FINISH..
AutoCAD SHX Text
ALL RAILING MATERIALS SHALL BE EXTRUDED ALUMINUM TUBE WITH CLEAR ANODIZED FINISH
SET GALV. STEEL PIPE SLEEVE, EMBED 8" MIN. IN CONCRETE
AutoCAD SHX Text
SEE STRUCTURAL DETAILS FOR REINFORCED CONCRETE RAMP AND PLATFORM DETAILS
AutoCAD SHX Text
SPEDIFIED LOADS: HANDRAILS AND HANDRAILS AND GUARDRAILS SHALL BE DESIGNED TO RESIST A LOAD OF 50 POUNDS PER LINEAR FOOT APPLIED IN ANY DIRECTION AT THE TOP AND TO TRANSFER THIS LOAD THROUGH THE SUPPORTS TO THE STRUCTURE. CONCENTRATED LOAD: HANDRAILS AND HANDRAILS AND GUARDS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED LOAD OF 200 POUNDS APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP, AND TRANSFER THIS LOAD THROUGH THE SUPPORTS TO THE STRUCTURE.
AutoCAD SHX Text
A. TOP AND BOTTOM RAILING EXTENSION AT RAMPS: RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE LANDING 12 INCHES MINIMUM BEYOND THE TOP AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR FLOOR, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN.
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
ISSUED FOR QUOTE: 07-15-19
AutoCAD SHX Text
Project No.
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Scale:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
a.
AutoCAD SHX Text
b.
AutoCAD SHX Text
c.
AutoCAD SHX Text
d.
AutoCAD SHX Text
e.
AutoCAD SHX Text
f.
AutoCAD SHX Text
A Professional Corporation of Architects and Planners
AutoCAD SHX Text
DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS
AutoCAD SHX Text
c GARRISON ARCHITECTS EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT
AutoCAD SHX Text
FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF GARRISON ARCHITECTS. WRITTEN DIMENSIONS ON THESE
AutoCAD SHX Text
. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION.
AutoCAD SHX Text
713 CREEK ROAD, BELLMAWR, NEW JERSEY 08031 (856) 396-6200
AutoCAD SHX Text
07-11-19
AutoCAD SHX Text
18-108
AutoCAD SHX Text
WOODSTOWN HIGH SCHOOL/MIDDLE SCHOOL EXTERIOR RAMP REPLACEMENT
AutoCAD SHX Text
140 EAST AVENUE WOODSTOWN, NEW JERSEY 08098
AutoCAD SHX Text
PLANS, ELEVATIONS & DETAILS
AutoCAD SHX Text
A-1
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
1
AutoCAD SHX Text
A-1
AutoCAD SHX Text
DEMOLITION PLAN
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
REMOVE EXISTING CONCRETE RAMP (INCLUDING FOUNDATIONS) & METAL HANDRAIL
AutoCAD SHX Text
PROPOSED NEW WORK LIMITS- REMOVE PORTION OF EXISTING ASPHALT AS REQUIRED TO CONSTRUCT NEW WORK.
AutoCAD SHX Text
2
AutoCAD SHX Text
A-1
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
RAMP DWN. 1:12
AutoCAD SHX Text
MTL. HANDRAIL W/ POSTS
AutoCAD SHX Text
WALL MOUNTED MTL. HANDRAIL
AutoCAD SHX Text
NEW CONCRETE LANDING AND RAMP TO EXISTING ASPHALT DRIVE
AutoCAD SHX Text
PATCH EXISTING ASPHALT DRIVE & SEAL TO NEW WORK
AutoCAD SHX Text
6" CONCRETE FILLEDSTEEL BOLLARD
AutoCAD SHX Text
3
AutoCAD SHX Text
A-1
AutoCAD SHX Text
RAMP SECTION
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
PROVIDE EXPANSION FELT & SEALANT WHERE RAMP/ LANDING ABUTS BUILDING
AutoCAD SHX Text
4
AutoCAD SHX Text
A-1
AutoCAD SHX Text
RAMP SECTION
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
5
AutoCAD SHX Text
A-1
AutoCAD SHX Text
RAMP SECTION
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
6
AutoCAD SHX Text
A-1
AutoCAD SHX Text
BOLLARD DETAIL
AutoCAD SHX Text
3/4" = 1'-0"
AutoCAD SHX Text
8
AutoCAD SHX Text
A-1
AutoCAD SHX Text
RAIL BASE DETAIL
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
1. ALL CONCRETE WORK SHALL CONFORM TO ACI 318 (LATEST EDITION). 2. CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE: a. FOUNDATIONS: 4000 PSI b. SLABS ON GRADE: 4000 PSI 3. CONCRETE SHALL NOT BE PLACED IN WATER OR ON FROZEN GROUND. 4. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60 DEFORMED BARS AND SHALL BE DETAILED, FABRICATED AND PLACED IN ACCORDANCE WITH ACI 315, LATEST EDITION. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 AND BE PROVIDED IN FLAT SHEETS. 5. REINFORCEMENT SHALL BE CONTINUOUS AROUND CORNERS AND AT INTERSECTIONS. PROVIDE CLASS "A" TENSION LAP SPLICES FOR ALL HORIZONTAL WALL REINFORCING UNLESS OTHERWISE SHOWN ON PLAN. PROVIDE CLASS "B" TENSION LAP SPLICES FOR ALL HORIZONTAL GRADE BEAM REINFORCING. 6. CLEARANCES FOR REINFORCEMENT: a. CONCRETE PLACED DIRECTLY ON EARTH, FOOTINGS: 3" b. SLABS, FROM TOP UNLESS OTHERWISE NOTED: 1" c. FORMED SURFACES EXPOSED TO WEATHER OR EARTH: #5 BAR OR SMALLER: 1 " 12" #6 BAR OR LARGER: 2" 7. CONTROL JOINTS IN SLABS ON GRADE: MAX. 200 S.F. SECTIONS a. CONTROL JOINTS SHALL BE LOCATED AS SHOWN ON SLAB ON GRADE PLAN. b. CONTROL JOINTS SHALL BE SAW CUT (1/3 THE SLAB DEPTH) AND FILLED WITH JOINT SEALER. CUT JOINTS AS SOON AS POSSIBLE WITHOUT FRAYING THE CONCRETE SURFACE. CONTROL JOINTS SHALL BE LOCATED BY CONTRACTOR IN ACCORDANCE WITH ACI CRITERIA, MAXIMUM SPACINGS AS PER TYPICAL SLAB ON GRADE DETAILS AND TYPICAL CONTROL JOINT LOCATION DETAILS (U.N.O.). MINIMUM CONTROL JOINT DEPTHS ARE INDICATED ON TYPICAL CONTROL JOINT DETAILS. CONTROL JOINTS WHICH ARE NOT PROMPTLY OR PROPERLY CUT AND ARE NOT FUNCTIONING SHALL BE RECUT BY THE CONCRETE CONTRACTOR. RECUTS OF JOINTS WHICH WERE NOT PROMPTLY OR PROPERLY CUT SHALL BE 3" DEEP MINIMUM. 8. THE FINISH TOLERANCE OF ALL SLABS SHALL BE IN ACCORDANCE WITH ACI 302 AND THAT SPECIFIED ON THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTION 03300 FOR FINISHING. 9. LAP ALL BARS A MINIMUM OF 40 DIAMETERS. LAP ALL WWF A MINIMUM OF 6 INCHES. 10. PROVIDE FOR ANY DEWATERING AS REQUIRED DURING EXCAVATION AND CONSTRUCTION OF THE FOUNDATION SYSTEM.