Announcements Artemia reports due today: please put on front desk. Paper today: Wongprasert et al. 2003 (Katie leads) Paper for next week: Jud et al. 2007 (Molly leads) Start computers, open lecture PP for simulations again. Revised Fluoview manual (PDF file) is available on Fluoview computer. TBA and assignment this week: Multi-channel imaging, including laser transmitted DIC Bright field contrast techniques Collect images of kidney slices and submit report (Fig. 1A: channel 1, 1B: channel 2, 1C: merge of channels 1 and 2; 1D: channel 3 (DIC image). Using references, describe some structures in your images in your figure legend.

Announcements

  • Upload
    byrd

  • View
    39

  • Download
    0

Embed Size (px)

DESCRIPTION

Announcements. Artemia reports due today: please put on front desk. Paper today: Wongprasert et al. 2003 (Katie leads) Paper for next week: Jud et al. 2007 (Molly leads) Start computers, open lecture PP for simulations again. - PowerPoint PPT Presentation

Citation preview

Page 1: Announcements

Announcements

• Artemia reports due today: please put on front desk.• Paper today: Wongprasert et al. 2003 (Katie leads)• Paper for next week: Jud et al. 2007 (Molly leads)• Start computers, open lecture PP for simulations again.• Revised Fluoview manual (PDF file) is available on

Fluoview computer.• TBA and assignment this week: Multi-channel imaging,

including laser transmitted DIC– Bright field contrast techniques– Collect images of kidney slices and submit report (Fig. 1A:

channel 1, 1B: channel 2, 1C: merge of channels 1 and 2; 1D: channel 3 (DIC image).

– Using references, describe some structures in your images in your figure legend.

Page 2: Announcements

MicrocopyFacility

Assistant

Johns HopkinsUniversity

General Description:

A microscopy specialist is sought to provide user support in Johns Hopkins School of Medicine Microscope Facility. This facility provides light, fluorescence and electron microscopy services to more than 200 users throughout Johns Hopkins. In addition to assisting with routine maintenance of the facility equipment and supplies, the candidate will help assist in training and supervising new users, as well as help users troubleshoot experiments. The candidate will also be trained to help users analyze images and data. Because of the diversity of equipment within the facility, we will provide initial training as necessary. Consequently, the candidate must display resourceful independence, a willingness to learn and have strong analytical skills. The primary duties of the candidate, when trained, will be to provide training and supervision for new users when they use one of many confocal and wide-field light microscopes (Zeiss, Olympus, and Nikon). Basic knowledge of cell biology is critical for communicating with users. Helping users with software and specimen preparation and interpretation may be needed as part of user services on projects. Regular duties include cleaning these microscope work areas and maintaining relevant supplies. Secondary duties will include collecting and maintaining a library of protocols, manuals and tutorials for users. With all duties, timely record-keeping (electronic & written) are required.

 

Qualifications:

https://hrnt.jhu.edu/jhujobs/job_view.cfm?view_req_id

=26703)

BS/BA, or equivalent, in biological sciences, chemistry, or related field required. Comparable laboratory experience may be substituted for some education. At least one year of relevant work experience required. Previous experience with fluorescence microscope imaging, including basic image processing, is required. Experience with specimen preparation for light microscopy (immunostaining, histology/pathology), confocal microscopy, or interpretation of cellular physiology in images is useful, but not required. Strong organizational skills coupled with strong interpersonal and communication skills (both oral and written) are essential.

NOTE: The successful candidate(s) for this position will be subject to a pre-employment background check

Page 3: Announcements

Paper Discussion Schedule• Today, Jan. 22 (Hertzler): Zucker 2006• Jan. 29 (Katie): Wongprasert et al. 2003• Feb. 5 (Molly): Jud et al. 2007• Feb. 12 (Becky): Anders 1988• Feb. 19 (Rachel): Tan et al. 2005• Feb. 26 (Ellen):• March 12 (Emily)• March 19 (Amy)• March 26 (Amanda)• April 2 (Andrea)• April 9 (Brittaney)• April 16 (Lauren)• April 23 (Joe and Molly):

Page 4: Announcements

Outline: Contrast Enhancement, Confocal Hardware

A. Resolution and sampling frequency: XY and ZB. Kohler Illumination and microscope setupC. Contrast Enhancement

1. Brightfield2. Interference of light3. Phase contrast4. Polarization5. DIC

D. Components of LSCM1. Scan Head2. Lasers3. Light Detectors

E. Week 4 TBA

Page 5: Announcements

Nyquist Sampling Theorem: XY

• Hibbs, p. 126: “When a continuous, analogue image is digitised, the information content of the signal will be retained only if the diameter of the area represented by each pixel is 2.3x smaller than the optical resolution limit of the microscope.”– So an objective with a theoretical

resolution of 0.2 μm requires a pixel size of 0.08 μm.

• How do you determine the pixel size (sampling frequency)?– Measure it with your scale bar at

different zoom factors:

From: Pawley, 2006. Handbook of Biological Confocal Microscopy. Springer: New York.

Page 6: Announcements

Nyquist sampling of an image of two points separated by the Rayleigh resolution

(Pawley 2006)

Sampling interval= d/2.3

From: Pawley, 2006. Handbook of Biological Confocal Microscopy. Springer: New York.

Page 7: Announcements

5. Axial Resolution (Z or raxial)• Minimum distance between the 3D diffraction patterns (PSFs) of two points along the Z axis that can still

be seen as two.

• From: Pawley, 2006. Handbook of Biological Confocal Microscopy. Springer: New York.

medium theofindex refractive theis η

andh wavelengt theis λ where

)(

22

objaxial NAr

Page 8: Announcements

5. Axial Resolution (Z or raxial)

μm 3nm 3093

0.5625

nm 1740

(0.75)

nm)(1.5) 2(580

)(

2

:lensNA 0.75 40XFor

2

2

axial

axial

objaxial

r

r

NA

nr

μm 0.9nm 888

1.96

nm 1740

(1.4)

nm)(1.5) 2(580

)(

2

:lensNA 1.4 60XFor

2

2

axial

axial

objaxial

r

r

NA

nr

• So with η = 1.5 for methyl salicylate:

Page 9: Announcements

Ideal step sizes

Ideal step size(higher Z resolution, e.g. NA=1.4)

Ideal step size(lower Z resolution, e.g. NA=0.7)

Undersampled(lower Z resolution, e.g. NA=0.7)

Page 10: Announcements
Page 11: Announcements

XY and Z resolutions (μm), XY Zoom andZ step sizes (1024 X 1024 box size)

Dye

λex/λem

10X

0.4 NA

20X

0.7 NA

40X

0.75 NA

60X

1.4 NA

rlateral

Zoom*

fluorescein

488/5180.790

4X

0.451

3X

0.421

1.5X

0.226

none

rlateral

Zoom*

rhodamine

543/5800.885

4X

0.505

3X

0.471

1.5X

0.253

none

raxial

Step+

fluorescein

488/5189.71

3.2

3.17

1.1

2.76

0.9

0.793

0.26

raxial

Step+

rhodamine

543/58010.9

3.7

3.55

1.2

3.09

1.0

0.888

0.30*Nyquist sample frequency of 2.3 +Nyquist sample frequency of 3.0

Page 12: Announcements

B. Kohler Illumination

• Purpose: Bright, even illumination without illuminating unnecessary areas or excess flare.

Steps1. Focus on the sample.2. Close field diaphragm until it can be

seen, focus and center the condenser.3. Open field diaphragm until it disappears

from view.

Page 13: Announcements

Upright Scope

BrightfieldSource

Epi-illuminationSource

Page 14: Announcements

Olympus BX50 Upright ‘scope

Page 15: Announcements

Inverted Microscope

BrightfieldSource

Epi-illuminationSource

Page 16: Announcements

C. Enhancing contrast in LMFibroblast in Culture: Four Types of Light Microscopy

Bright-Field Phase-Contrast

Differential Interference Contrast Dark-Field

Page 17: Announcements

1. Bright-field microscopy

• Is the simplest, but object must be colored to be seen. Histological staining usually requires killing the sample.

• Staining utilizes absorption; e.g. red stain absorbs green and blue light, passing only red light. The specimen is now an amplitude object, where contrast is seen by reducing the amplitude of certain wavelengths of light.

• Microscopy of living cells, which are usually transparent, are limited by contrast, or the difference between light and dark.

• How can we see them without staining them?– By exploiting the fact that samples are phase objects, which slow

light down relative to other parts of specimen or to background.

Page 18: Announcements

2. Interference

Page 19: Announcements

3. Phase-Contrast Microscopy

• Annular Ring in Phase Condenser focuses cone of light onto sample.– Specimen light is shifted -1/4

wavelength

• In Phase ring of Objective:– Direct light (background) passes

through thin, dark part.– Diffracted light (specimen) passes

through thick, light part, shifted -1/4 wavelength.

• Specimen light shifted by ½ wavelength total.

• Rings must be aligned to get phase effect.

Page 20: Announcements

Alignment of phase rings

• Jave tutorial:

http://micro.magnet.fsu.edu/primer/java/phasecontrast/phasemicroscope/index.html

ALIGNED

Page 21: Announcements

Phase Contrast Microscope• Surround wave (red) is undiffracted light that passes around and through the sample.• Diffracted wave (blue) interacts with sample, is retarded by ¼ wavelength relative to

S wave.• Particle wave (green) results from interference between S and D waves. Amplitude

difference between S and P determines the level of contrast• PC scope shifts diffracted beam from specimen an additional ¼ wavelength to ½ λ,

creating maximal destructive interference between S and D.• Causes decrease in amplitude (brightness) in P, which can be seen against brighter

background.

λ/2

Object dimmerBackground bright

Object brighterBackground dimmer

Page 22: Announcements

Limitations of Phase Contrast

• Phase images are usually surrounded by halos around the outlines of details. Such halos are optical artifacts, which sometimes obscure the boundaries of details.

• The phase annuli do limit the working numerical aperture of the optical system to a certain degree, thus reducing resolution.– 20X PlanApo 0.7 NA compared with 20X Phase 0.4 NA.

• Phase contrast does not work well with thick specimens because shifts in phase occur from areas slightly below or slightly above the plane that is in focus. Such phase shifts confuse the image and distort image detail.

Page 23: Announcements

4. Polarization Microscopy• Useful for crystalline

materials or oriented structures in biological materials, e.g.– Mitotic spindle fibers– Microfilament bundles– Striated muscle fibers

• These structures are said to be birefringent (having double refraction), meaning that they have at least two refractive indices.

Birefringent skeleton in sea urchin larva

Page 24: Announcements

Polarization of Light

AKAAnalyzer

Note: laser light is already polarized

Page 25: Announcements

Polarizing Sunglasses

• Human eye can’t detect difference in randomly oriented versus polarized light.

• When polarizing sunglasses filter out parallel waves, eye detects less glare, lower amplitude.

Page 26: Announcements

Isotropic versus anisotropic materials

n2

n1

n1

n1

n1

Light slowed more when vibrating E-W

Isotropic:Glass, salt

Anisotropic (birefringent – with twoRefractive indices):

Sugar, muscle, gout crystals

Light slowed less when vibrating N-S

Light slowed equally vibratingin any direction.

Page 27: Announcements

Birefringence

• First clue to explanation of polarization came from observation of calcite crystals by Erasmus Bartholin in 1669.

• http://www.microscopy.fsu.edu/primer/java/polarizedlight/icelandspar/index.html

• One of the light rays emerging from a birefringent crystal is termed the ordinary ray, while the other is called the extraordinary ray.

Split, bothPolarized;perpendicular

Incident ray oblique to optical axis of crystal

Page 28: Announcements

Incident light perpendicular to optical axis of specimen: same trajectory,different path length causes interference when recombined.

Page 29: Announcements

Birefringent samples oriented 45o to crossed polarizers are maximally bright

• Java tutorial: http://micro.magnet.fsu.edu/primer/java/polarizedlight/crystal/index.html

Page 30: Announcements

5. Differential Interference Contrast

• Also called Nomarski optics; uses plane polarized light.• Similar to Phase Contrast in that light from low contrast sample is

caused to interfere destructively to produce amplitude changes.• Produces contrast where changes in thickness, slope, or refractive

index occur in cell, especially along edges, to give a pseudo three dimensional appearance.

Page 31: Announcements

Red blood cells Cheek cells Filamentous alga

DIC images have no halos.

Page 32: Announcements

DIC produces superior axial resolution, optical sectioning.

Page 33: Announcements

DIC Pathway:Components

• Light from lamp passes through Polarizer, is separated into O and E waves by Wollaston Prism (specific to each lens), then to Condenser.

• Phase specimen creates different optical path lengths for O and E, shifting their phase.

• After passing through specimen, light passes through Objective, and is recombined, resulting in interference, by second Wollaston Prism, then to Analyzer (second Polarizer) to Eyepiece.

Page 34: Announcements

Effect of Bias Retardation in Analyzer

• Controls how O and E waves are recombined.

• Affects brightness, contrast, and color (optical staining) of specimen.

• Java tutorial: http://micro.magnet.fsu.edu/primer/java/dic/lightpaths/index.html

Page 35: Announcements

Advantages, Disadvantages of DIC• Advantages:

– Uses full NA of the lens, achieving optimal resolution and some optical sectioning ability.

– Provides optical color staining.– No phase halos as with phase contrast.

• Main Disadvantage:– Tissue culture plastic or birefringent sample

features can produce confusing effects.

Page 36: Announcements

D. Confocal Hardware

Page 37: Announcements

1. Fluoview 300 Scan Head Anatomy

12

3 4

6

7

9

10

8 Beam splitter

5

Page 38: Announcements

2. Lasers available for Olympus Fluoview Confocal Microscopes

• Blue argon-ion (488 nanometer) laser (WE HAVE)• Multi-line argon-ion (457, 488, and 514 nanometers)

laser • Green helium-neon (543 nanometer) laser (WE HAVE)• Red helium-neon (633 nanometer) laser (WE MAY GET)• Yellow krypton-ion (568 nanometer) laser • Blue-violet helium-cadmium (442 nanometer) laser • Violet and blue-violet diode (405 and 440 nanometer)

lasers • Ultraviolet argon-ion (351 nanometer) laser • Infrared (750 nanometer) laser

Page 39: Announcements

Adjusting Offset and PMT/Gain to maximize range of grey levels collected

Figure 5(a) illustrates the raw confocal image along with the signal from the photomultiplier. After first applying a negative offset voltage to the photomultiplier, the signal and image appear in Figure 5(b). Note that as the signal is shifted to lower intensity values, the image becomes darker (upper frame in Figure 5(b)). When the gain is next adjusted to the full intensity range (Figure 5(c)), the image exhibits a significant amount of detail with good contrast and high resolution.

Pixel intensity256 (4047)

0

Page 40: Announcements

Note on Building stereo images

• Stereo Factor: Sets the deviation between the left and right eyes when building a pair of stereo 3D images or a 3D image to be viewed through color (red/green) eyeglasses.– You can change this.

• Z Stretch Factor: Provides each section with a feeling of thickness. Usually this value does not need to be changed.

Page 41: Announcements

Week 4 TBA

• Kohler illumination• Phase contrast• Polarization• DIC• Laser transmitted DIC• Assignment: Collect multi-channel

fluorescence and laser transmitted images of prepared kidney slide, save, submit report as before.