ALCATEL 1660SM /1650SMC 多工機簡介 承包廠商:台灣國際標準電子股份有限公司 日期:2005/5/23 – 2005/5/26

ALCATEL 1660SM /1650SMC 多工機簡介

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

> 64x64 STM-1 equivalent LO matrix Interfaces
> Network protection • EPS
• SNCP (N and I) at all VC layers
Page 3
> 32x32 STM-1 equivalent SDH matrix (HO/LO)
> Interfaces: • up to 16 STM-1 • up to 12 140 Mbps (P4E4N and
A2S1) • up to 5 STM-4 • up to 63 2 Mbps • up to 9 34/45 Mbps
> EPS protection on traffic ports and centralized units
> Network protection • MSP on STM-n ports • SNCP
34/45 Mbps STM-1
standards for SDH equipment
memories, …)
> EPS (Equipment Protection Switching): • EPS on each equipment parts (excluding Access Boards)
• EPS for Matrix is hitless if operated by “Force” command
> Network Protection: • 1+1 and 1:1 Linear MSP on all STM-n interfaces (single / dual ended)
• HO/LO SNCP/I and SNCP/N between any SDH interface (SNCP/I only)
• 2 fibers MS-SPRing at STM-16
Page 6
> EPS: gMatrix 1+1 gPDH ports
g APS: gSTM-N linear single-ended 1+1 APS (MSP) gSNCP/I gDrop &Continue for Dual Ring Protection
g APS: g2F MS-SPRING
NE Side BSide A
NE NEPDH PORTS PDH PORTS
SDH PORT SDH PORT
SDH PORT
RING 1
RING 2
NE
NENE
NENE
NE
NE
PORTS
PORTS
NE
Each interconnecting node can have one single NE or two NEs.
In case of one sigle NE the D&C CXC at TU level must be
adopted.
> Infomodel Craft Terminal through RS-232 (38 Kbit/s) Remote Craft
Terminal
> Management of up to 32 DCC channels (with automatic re-routing)
> Complete network compatibility with existing equipment and TMN (IS-IS, NTP, Dual OS)
> Interchangeable PCMCIA Flash Card for non-volatile data
Page 12
• Equipment Controller (EC): − 1 processor for QB3 interface, Message Communication Function (MCF) and
database management
• SDH Matrix: − 1 processor for Shelf Control (SC) − 1 Performance Monitoring co-processor
• No processors on Traffic Units (e.g. 63x2Mb/s Port card)
Page 13
The access area:
slot 10: CONGI A
Page 14
slot 7: High speed Port Cards
6.6.--16501650SMSM--CC
• 4 x 140M/STM-1 switchable
• 4 x STM-1 electrical
• 1 x STM-4 optical
• 1 x STM-16 optical
• 1 x STM-4 optical
• 3 x 34 Mbit/s
• 3 x 45 Mbit/s
• 4 x STM-1 electrical
• High speed protection
• STM1 electrical /optical Module
• 21 x 2 Mbit/s
• 3 x 34 Mbit/s
• 3 x 45 Mbit/s
• 4 x 140/STM-1 electrical
protection only)
Page 19
Traffic units except 2Mbit/s Electrical access modules 2xSTM-1 Optical Access Module Electrical protection for High Speed interfaces
19”
Housekeeping, QB3 (10base2 and
10baseT), Q2/RQ2, Power A;
B;
MATRIX : 96x96 STM-1 Matrix&CRU, SC;
EQUICO : Equipment Controller (EC).
SYNTH1: 2xSTM-1 or 1xSTM-4
CRU & Equipment Controller
Page 22
MATRIX
10. 10. : :
> LS Port Card: • N+1 EPS protection (N=1...6).
− Spare Board has to be plugged in the slot 32. The same access cards are shared between main and spare ports.
− Only one protection scheme
> HS Port Card: • N+1 EPS protection only for HS electrical ports (N=1....15 with max 8
protection schemes). The constraints are the following: − for the protecting port the corresponding access card has to be an HPROT
access card (without connectors) − the protecting card has to be plugged at the left side of the protected port or
ports (the same rule has to be respected by the corresponding access cards).
− the main/spare ports have to be adjacent.
Page 25
3.16. 3.16. EPSEPS
> EPS protection is applicable to the PDH/SDH traffic cards with electrical interfaces. In the latter case the EPS is applied to the interface traffic card only; the access module cards are part of the line and unprotected. General characteristics of the EPS protection mode are:
> Switching criteria: card-missing, card-fail
> Switching time: max 50ms • Operation mode:
− 1+1 EPS always non-revertive − N+1 EPS always revertive w/ fixed WTR = 5 minutes
> External commands to control the switch position: Manual, Force, Lockout, Clear
Page 27
BRIDGE
SWITCH