Alternative Fuel Systems Inc. Bay 1, 4321 – 14 th Street N.E., Calgary, Alberta, Canada T2E 7A9 (403) 262-1833 Main (403) 237-7441 Fax [email protected] www.afsglobal.com FUEL TYPES: APPLICATION: ENVIRONMENTAL TEMPERATURE NOMINAL OPERATING VOLTAGE MINIMUM OPERATING VOLTAGE RESPONSE TIME, OPEN AND CLOSE (AT RATED PRESSURE): SEALING: INJECTOR TO INJECTOR VARIABILITY: CYCLE TO CYCLE VARIABILITY: VIBRATION: TYPICAL DRIVER TYPES: DURABILITY: CNG/LCNG/LPG/H 2 PORT/THROTTLE BODY INJECTOR -40 o C to 120 o C 12 VDC and 24 VDC 7 VDC for 12 VDC nominal injector Less than 2 ms for 8:2 Amp <20cc/h as per ISO 15500 ±2.5% rated; ±4% at idle ±1% Per ISO 15500 8 Amp, 2 Amp peak and hold 4 Amp, 1 Amp peak and hold Dedicated driver module available 500 million cycles

AFS Injector

  • Upload
    pejki

  • View
    78

  • Download
    1

Embed Size (px)

Citation preview

Page 1: AFS Injector

Alternative Fuel Systems Inc. Bay 1, 4321 – 14th Street N.E., Calgary, Alberta, Canada T2E 7A9 (403) 262-1833 Main (403) 237-7441 Fax [email protected] www.afsglobal.com

FUEL TYPES: APPLICATION:

ENVIRONMENTAL TEMPERATURE NOMINAL OPERATING VOLTAGE MINIMUM OPERATING VOLTAGE

RESPONSE TIME, OPEN AND CLOSE (AT RATED PRESSURE): SEALING:

INJECTOR TO INJECTOR VARIABILITY: CYCLE TO CYCLE VARIABILITY:

VIBRATION: TYPICAL DRIVER TYPES:

DURABILITY:

CNG/LCNG/LPG/H2 PORT/THROTTLE BODY INJECTOR -40oC to 120oC 12 VDC and 24 VDC 7 VDC for 12 VDC nominal injector Less than 2 ms for 8:2 Amp <20cc/h as per ISO 15500 ±2.5% rated; ±4% at idle ±1% Per ISO 15500 8 Amp, 2 Amp peak and hold 4 Amp, 1 Amp peak and hold Dedicated driver module available 500 million cycles

Page 2: AFS Injector

Version: 15.AB.01 Released: 2003-06-16

Test conditions and Assumptions

1. Calibration is for pure methane and propane only. Common CNG and LPG automotive fuels may vary significantly in composition, with significant calibration effects.

2. Injector is driven using AFS 8 Amp:2 Amp custom driver circuit. Other driver circuits will affect injector dynamics and therefore flow calibration.

3. Tests conducted at 90 kPa atmospheric pressure. Flow rate will increase with increased atmospheric pressure. 4. Backpressure at the injector outlet is assumed to be atmospheric pressure. Flow rates will change with backpressure created by

installation plumbing or other application details. 5. Calibration is for gas at 30oC

Gs60 Injectors With Methane at Various Input Pressures Gs60-06-5-A

0

20

40

60

80

100

120

140

0 5 10 15 20

Pulse Width (ms)

Met

hane

Flo

w (m

g/in

j)

Injectors run at 50Hz 2003-06-12

600 kPag

500 kPag

400 kPag

300 kPag

200 kPag

100 kPag

Gs60 Injectors With Propane at Various Input PressuresGs60-06-2-A

0

10

20

30

40

50

60

70

80

90

0 5 10 15 20Pulse Width (ms)

Prop

ane

Flow

(mg/

inj)

2003-06-09Injectors run at 50Hz

2.0 bar

1.0 bar

1.5 bar