AFD/TFD Service. Agenda. Set-up Fault code retrieval Testing unit components Testing the power door Cleaning . Set Up Mode. In the Set Up Mode you can Set the cleaning interval for the pre filter Set the cleaning interval for the collector cells Set the power level. Pre Filter. - PowerPoint PPT Presentation

Citation preview

Page 1: AFD/TFD Service

AFD/TFD Service

Page 2: AFD/TFD Service

Agenda

• Set-up• Fault code retrieval• Testing unit

components• Testing the power

door• Cleaning

Page 3: AFD/TFD Service

Set Up Mode

• In the Set Up Mode you can– Set the cleaning

interval for the pre filter

– Set the cleaning interval for the collector cells

– Set the power level

R3R2R1Y4Y3Y2Y1G3G2G1

R3R2R1Y4Y3Y2Y1G3G2G1

R3

R2

R1

Y4

Y3

Y2

Y1

G3

G2

G1

Pre Filter Collector Cells Power Level

Dirty

Clean

Dirty

Clean Clean

Dirty

Page 4: AFD/TFD Service

Set-Up Mode

• Enter the set up mode by pressing and holding power and reset buttons for 5 seconds

• The display will indicate how the unit is programmed

• The factory settings are displayed

• To change settings press power button once

R3

R2

R1

Y4

Y3

Y2

Y1

G3

G2

G1Clean

Dirty

Factory Settings

Page 5: AFD/TFD Service

Set-Up Mode

• Scroll through the settings by repeatedly pressing reset button

• To save the settings and advance to the next setting press the power button once

• Exit the set up mode by pressing and holding power and reset buttons for 5 seconds

R3

R2

R1

Y4

Y3

Y2

Y1

G3

G2

G1

3 Months

Clean

Dirty R3

R2

R1

Y4

Y3

Y2

Y1

G3

G2

G1

9 Months

R3

R2

R1

Y4

Y3

Y2

Y1

G3

G2

G1

9.6 KVDC

Pre-Filter Collection Cells Power Level

Page 6: AFD/TFD Service

Time Delays

• 10 second time delay on a call for cooling• 90 second time delay on a call for heating• 10 minute time delay anytime the power to the

air cleaner is turned off and on.Thermostat Call Delay

0102030405060708090

100

1 2

Tim

e in

Sec

onds

Power On Delay

0

100

200

300

400

500

600

700

1

Tim

e in

Sec

onds

Page 7: AFD/TFD Service

Normal Operation

• During normal operation the green LED #1 with flash slowly when the blower is operating

• There may be some other LED’s on based upon time to clean intervals

R3R2R1Y4Y3Y2Y1G3G2

G1

Page 8: AFD/TFD Service

Need for Service

• Three yellow flashing LED’s indicates the controls have detected 10 consecutive high voltage shut downs

• Three red flashing LED’s indicates the controls have detected the same fault 3 times in a row after a high voltage shut down

R3

R2

R1

Y4

Y3

Y2

Y1

G3

G2

G1

Page 9: AFD/TFD Service

Fault Code Retrieval

• To enter the fault code log– Go into the set up mode

(press and hold power and reset for 5 seconds)

– Press and hold reset for 10 seconds

• Display goes out• Green LED #1 and a

combination of yellow and red LED’s indicate the first recorded fault in the log

Y4

Y3

Y2

R1

Y1

G3

G2

G1

R2

R3

Page 10: AFD/TFD Service

Fault Code Log

• Matching the pattern of LED flashes will give an indication of what fault has been posted to the fault code log

• The column on the right of the chart will provide the recommended service procedure for that fault

• An example is service procedure #5 is for repetitive arcing. The service procedure is to clean collection cell and field charger and check for arcing through plastic frame to cabinet

Page 11: AFD/TFD Service

Clear Fault Code Log

• To clear all 3 fault codes from the log– Press and hold the reset button 2 to 4

seconds while the fault codes are being displayed

– The red and yellow LED’s will go out – The green LED will remain on to indicate

which fault code number is being displayed• To exit fault code log press and hold the

power and reset buttons for 5 seconds

Page 12: AFD/TFD Service

Test Unit Components

• There are 4 tests that can be performed using internal unit controls– High voltage relay test– LED test– High voltage output test– Thermostat input test

Page 13: AFD/TFD Service

Test Unit Components

• Entering the component test mode– Press and hold the power button until all ten LED’s

come on then release the power button. The air cleaner is now off and LED’s should step off one at a time

– Press the reset button 3 times in a row within 20 seconds of the LED’s stepping off

– The pre-filter light will come on– Quickly press and hold the power and reset buttons at

the same time – The pre-filter LED will begin to flash and continue to

flash as long as the unit is in the component test mode.• The green LED #1 should be on

Page 14: AFD/TFD Service

Test Unit Components

The green LED’s will show which of the tests the controls are in

Page 15: AFD/TFD Service

High Voltage Relay Test

• Green LED #1 “on” indicates high voltage relay test mode

• There are 3 tests within the high voltage relay section

• Yellow LED’s indicate the test being performed

Page 16: AFD/TFD Service

High Voltage Relay Test

• The red LED’s show the condition of each test

• The read out indicates– High Voltage Relay

test– High voltage input

current test– Condition is within

range

R3

R2

R1

Y4

Y3

Y2

Y1

G3

G2

G1

Page 17: AFD/TFD Service

LED Test

• To advance from the high voltage relay test to LED test press the power button once

• All 10 LED’s will come on

• Press the reset button once to turn each individual LED off

R3R2R1Y4Y3Y2Y1G3G2G1

Page 18: AFD/TFD Service

High Voltage Output Test

• Pressing the power button once will advance the controls to high voltage output test

• There are 4 high voltage output tests in this section• The tests range from 0 VDC to 9.6KVDC output

Page 19: AFD/TFD Service

High Voltage Output Test

• Green LED’s 1 & 2 will be on for these tests

• Yellow LED’s indicate which test is being performed

• Red LED’s indicate the condition of the test

• The display indicates – High voltage output test (Green LED’s)– 9.6KVDC output test (Yellow LED)– Output is within range (Red LED)

• If test 1 is rerun after completing other tests it will take a few seconds for the condition to come into range

R3R2R1Y4Y3Y2Y1G3G2G1

Page 20: AFD/TFD Service

Thermostat Input Test

• Press the power button once to advance to thermostat input test

• There are 3 tests in this section• A thermostat call for heat (W)

• A thermostat call for indoor blower (G)• 24VAC input to the air cleaner

Page 21: AFD/TFD Service

Thermostat Input Test

• This display indicates– Thermostat input test

(green LED)– A thermostat call for

indoor blower (G) (yellow LED)

– 24VAC input voltage is below minimum range (red LED)

• Low 24VAC input could be the result of VA rating of transformer

R3R2R1Y4Y3Y2Y1G3G2G1

Page 22: AFD/TFD Service

Exiting Component Test

• There are 3 ways to exit the component test mode

• Press and hold the power and reset buttons of 5 seconds

• Remove 24 volt power supply to the air cleaner

• Wait 5 minutes without touching any buttons

Page 23: AFD/TFD Service

Power Door Test

• Tools required– A high voltage probe and

compatible volt/ohm meter or

– A screwdriver, jumper wire with alligator clips, tape and dry paper

• Turn off the air cleaner and remove the power door

• Form a piece of wire to be used to depress the door interlock switch

Page 24: AFD/TFD Service

Power Door Test

Caution high voltage is present for this test

• Turn the air cleaner on and enter the set up mode

• Adjust the power setting for normal (9.6 KVDC)

• Exit the set-up mode and wait for green LED #1 to begin to flash

• Connect the high voltage probe per manufacture instructions

• Touch the center contact of the power door

• The voltage should read 9.6KVDC +/- 600 volts

Page 25: AFD/TFD Service

Power Door Test

• Using a screwdriver, jumper wire, and dry paper

• Tape a piece of paper to the screwdriver extending ½” beyond the end

• Connect the jumper wire from the screwdriver shaft to the ground contact of the power door

Page 26: AFD/TFD Service

Power Door Test

• Form a piece of wire to depress the door interlock switch• Turn the air cleaner on and enter the set up mode• Adjust the power setting to normal (9.6KVDC)• Wait for green LED #1 to begin to flash • Take the plastic handle screwdriver move it close to center

power door contact• When the paper touches the center contact the power

supply should arc to the screwdriver• When the arc occurs the power supply will shut down for 10

minutes• If the arc occurs when the paper is near or touching the

contact the power supply is good• If no arc occurs the power supply is bad. Replace the

power door

Page 27: AFD/TFD Service

Cleaning

• Pre-filter cleaning– The pre-filter may be vacuumed or washed – It should be completely dry before re-installing

• Collection cell cleaning– The collection cells may be vacuumed or

washed– Vacuum both sides– Wash using low pressure sprayer. Warm

water will remove some residue

Page 28: AFD/TFD Service

Cleaning

• Do Not– Use soap or detergents on collection cells– Immerse collection cells completely in water– Place collection cells into a dishwasher

• If water is used in cleaning collection cells– Slightly tap the collection cell to remove water– The collection cell must be dry before re-installing

• Reset filter timers– Reset pre-filter timer: press and hold the reset button

until pre-filter LED goes out (1 to 2 seconds)– Reset collection cell timer: press and hold reset button

until collection cell LED’s go out (4 to 5 seconds)

Page 29: AFD/TFD Service

Cleaning

• Cleaning field charger– Field charger should be

cleaned annually• Turn air cleaner off and

remove power door• Bend field charge

locking tab down and remove field charger

• Wipe face plate with dry shop towel or vacuum

Field charger locking tab

Page 30: AFD/TFD Service

Field Charger Cleaning

• Power off for minimum 15 seconds– Remove from case and lay on

flat surface• Bend locking tab down and

remove field charger • Wipe face with shop towel

– Do not disassemble the field charger

• Use a piece of foam to clean ionizing pins and faceplate leading edges– Ionizing pins are easy to bend

Page 31: AFD/TFD Service

Cleaning

• Caution field charger pins are sharp– Do not bend pins– Wear gloves

• Use a block of foam to clean the pins– Push the foam block over

the pin– Rotate the foam block – Use the foam block to clean

faceplate opening edges• Reinstall field charger and

bend one locking tab

Page 32: AFD/TFD Service

Trouble Shooting

• Air Passing Through the Cleaner Emits a Slight Sound– Select Lower “Power Setting” in the “Set Up”

Mode to Reduce– Minimal Impact on Cleaning Efficiency

Page 33: AFD/TFD Service

AFD/TFD Summary

• What we covered– Set-up– Fault code retrieval– Testing unit components– Testing the power door– Cleaning

• There is a more detailed training available from Learning Resources. Look for details on Thursday during the general session.