23
REFERENCE SYMBOL 2415 SAN RAMON VALLEY BLVD #306 SAN RAMON, CA 94583 USA SHEET INDEX NAME ROOM NAME SHEET NUMBER ELEVATION NUMBER 1 2 3 4 8'-4" CEILING HEIGHT BLDG. SECTION LETTER X AX.X BLDG. SECTION SHEET DETAIL NUMBER X AX.X DIRECTION OF DETAIL DETAIL SHEET REVISION NUMBER X BLDG. HEIGHT REFERENCE POINT 0'-0" ELEV DETAIL NUMBER DETAIL SHEET X AX.X AX.X X X X X X-000 XX NOTE CODED NOTE EXTERIOR WALL FINISH NUMBER KEY NOTE EQUIPMENT NUMBER ROOM FINISH NUMBER INTERIOR ELEVATION DESIGNATION X X SHEAR WALL TYPE (STRUCTURAL) EQUIPMENT / FIXTURE NUMBER (M.E.P.) XXX 000 BLDG. ELEVATION LETTER X AX.X BLDG. ELEVATION SHEET VICINITY MAP PROJECT GENERAL NOTES RESPONSBILITY MATRIX KEY PLAN A. ALL WORK SHALL CONFORM TO THE 2012 EDITION OF THE INTERNATIONAL BUILDING CODE, AND ALL OTHER APPLICABLE CODES, STANDARDS, AND REGULATIONS OF THE CITY OF CALIFORNIA AND COUNTY OF CONTRA COSTA. B. IT IS INDEED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. C. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. A2.0 LATEST EDITION) ARE A PART OF THESE CONTRACT DOCUMENTS. D. DRAWINGS ARE BASED ON A SURVEY, DATED __________,20XX PREPARED BY "XXXX". E. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO STARTING WORK. F. ALL PROPOSED SUBSTITUTIONS SHALL BE PROVIDED BY THE CMA PROJECT MANAGER, IN WRITING, PRIOR TO INSTALLATION. G. ONLY THE BUILDING PLAN REVIEW FEE IS DUE AT SUBMITTAL, ALL OTHER FEES ARE DUE AT THE TIME OF PERMIT ISSUANCE. H. PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY-PERMITTED DRAWING SET AT A TIME OF CONSTRUCTION. I. ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACT ARCHITECT IF ANY ABBREVIATIONS ARE NOT CLEAR. J. G.C. SHALL SUPPLY AND INSTALL ALL ASPECTS OF THE PROJECT DESCRIBED IN THIS DRAWING SET UNLESS OTHERWISE NOTED. K. GRAPHIC AND WRITTEN INFORMATION ON DRAWINGS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO INSTALLATION. PROJECT DIRECTORY OWNER: XXX XXXX XXXX, LLC 2415 SAN RAMON VALLEY BLVD, SAN RAMON, CA 94583 OWNER CONTACT: XXXX XXXX ARCHITECT: XXX XXX XXX XXX XXX PROJECT MANAGER: XXX XXX LEGAL JURISDICTION: SAN RAMON COUNTY CODE: BUILDING: 2016 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24 ACCESSIBILITY: 2016 CALIFORNIA BUILDING CODE CHAPTER 11B CALIFORNIA CODE OF REGULATIONS TITLE 24 MECHANICAL: 2016 CALIFORNIA MECHANICAL CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 4 PLUMBING: 2016 CALIFORNIA ELECTRICAL CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 5 ELECTRICAL: 2016 CALIFORNIA ELECTRICAL CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 3 ENERGY: 2016 CALIFORNIA ENERGY CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 6 FIRE: 2016 CALIFORNIA FIRE CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 9 HEALTH: COUNTY OF SAN RAMON HEALTH SYSTEM BUILDING AREA: XXXX SF SEATING: INTERIOR - 66 SEATS OCCUPANCY: A2 TYPE OF CONSTRUCTION: II-B TOTAL OCCUPANTS: XXX N NORTH N N BUILDING CODE CLASSIFICATION COVER SHEET T1.0 THESE DOCUMENTS ARE PROVIDED AS A CONSTRUCTION DOCUMENT TEMPLATE FOR THIS BUILDING TYPE. THESE DRAWINGS MUST BE REVIEWED AND ADAPTED BY A LICENSED ARCHITECT AND/OR ENGINEER TO MEET ALL STATE AND LOCAL JURISDICTIONAL REQUIREMENTS FOR SITE SPECIFIC PROJECTS. MODIFICATIONS THAT CHANGE THE IMAGE ELEMENTS OR KITCHEN OPERATIONS MUST BE APPROVED BY A YUM! BRANDS REGIONAL ARCHITECTURAL PARTNER (RAP) PRIOR TO CONSTRUCTION. SEAL REMOVE THIS DISCLAIMER PRIOR TO PRINTING - REPLACE WITH CONSULTANT'S LOGO. CONTRACT DATE: BUILDING GROUP: FLOOR PLAN: SITE NUMBER: STORE NUMBER: BRAND DESIGNER: TACO BELL SAN RAMON 2415 SAN RAMON VALLEY BLVD #306 SAN RAMON, CA 94583 USA XXXXX XX-XX NOV-13-2019 CD SET DATE: EMERGENCY LIGHTS & EXIT SIGNS SECURITY ALARM & WIRING STOCKROOM SHELVING EQUIP'T SPEAKER WIRING SOUND SYSTEM LIGHT FIXTURES & LAMPS MILLWORK FLOOR FIXTURES SAFE FIXTURES INSTALL BY GENERAL ELECTRICAL WIRING CONCRETE FLOORING- SALES FLOOR NEW PLUMBING LINES IN SPACE PLUMBING FIXTURES & ACCESSORIES PLUMBING (WASTE, VENT & WATER) TO SPACE FIRE ALARM & EMERGENCY PAGING SYSTEM FIRE EXTINGUISHERS & CABINETS SPRINKLER LINES & HEADS SPRINKLER MAIN TO SPACE MECHANICAL SUPPLY & RETURN DUCTING MECHANICAL EQUIPMENT (UNITS) TELEPHONE TERMINATIONS ELECTRIC WATER COOLER VINYL BASE FLOOR TRANSITIONS PAINT- SALES AREA FINISHES MECHANICAL CONTROLS ELECTRICAL SERVICE CONDUIT & WIRE TO SPACE INTERIOR GRAPHICS & SIGNAGE METAL DOORS AND FRAMES STOREFRONT GLASS, & FRAMING OTHER INTERIOR PARTITIONS & PREP DEMISING PARTITION GYPSUM BOARD & PREP DEMISING PARTITION: (METAL STUD/MASONRY) ALL DOOR HARDWARE STOREFRONT SIGNAGE ASBESTOS REMOVAL INSULATION FLOOR LEVELING FIRE PROOFING TENANT G.C. TENANT LANDLORD TENANT LANDLORD FURNISH BY TENANT G.C. REMARKS MOP SINK EXISTING EXISTING ELECTRICAL WIRING & RECEPTACLES PAINT- DECK/ STEEL/ ETC EMPLOYEE BREAK TABLE/SHELVING MANAGER'S DESK/SHELVING WALLPAPER SECURITY MIRRORS / CAMERAS FIXTURE ASSEMBLY STOCK SHELVING CORNER UNITS UNIT HEATERS FRP PANELS TELEPHONE CONDUIT TO SPACE CONCRETE FLOORING- STOCKROOM / MANAGERS OFFICE TILE FLOORING PAINT- RESTROOMS/ MANAGERS OFFICE/ STOCKRM NOTES: 1. WORK DESIGNATED BY L.L. IS LANDLORD RESPONSIBILITY 2. WORK DESIGNATED BY T.G.C. IS TENANT GENERAL CONTRACTOR RESPONSIBILITY 3. WORK DESIGNATED BY TB IS TACO BELL RESPONSIBILITY TELEPHONE WIRING MECHANICAL THERMOSTATS MODIFICATIONS/REPAIRS BY TENANT GC AS REQUIRED RELOCATION REPLACEMENT BY TGC MODIFICATIONS/REPAIRS BY TENANT GC MODIFICATION BY TENANT GC RELOCATION BY TENANT GC NEW BY TENANT GC RELOCATION BY TENANT GC RELOCATE EXISTING NEW/ RELOCATE BY TENANT GC NEW/ RELOCATE BY TENANT GC

ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

REFERENCE SYMBOL

2415 SAN RAMON VALLEY BLVD #306SAN RAMON, CA 94583 USA

SHEET INDEX

NAME ROOM NAME

SHEET NUMBER

ELEVATION NUMBER

1

2

3

4

8'-4" CEILING HEIGHT

BLDG. SECTION LETTERX

AX.XBLDG. SECTION SHEET

DETAIL NUMBERX

AX.XDIRECTION OF DETAIL

DETAIL SHEET

REVISION NUMBERX

BLDG. HEIGHTREFERENCE POINT

0'-0"ELEV

DETAIL NUMBER

DETAIL SHEET

XAX.X

AX.X

X

X

X

X

X-000

XX

NOTE

CODED NOTE

EXTERIOR WALL FINISH NUMBER

KEY NOTE

EQUIPMENT NUMBER

ROOM FINISH NUMBER

INTERIOR ELEVATION DESIGNATIONX

X SHEAR WALL TYPE (STRUCTURAL)

EQUIPMENT / FIXTURE NUMBER (M.E.P.)XXX 000

BLDG. ELEVATION LETTERX

AX.XBLDG. ELEVATION SHEET

VICINITY MAP

PROJECT GENERAL NOTES

RESPONSBILITY MATRIX

KEY PLAN

A. ALL WORK SHALL CONFORM TO THE 2012 EDITION OF THE INTERNATIONALBUILDING CODE, AND ALL OTHER APPLICABLE CODES, STANDARDS, ANDREGULATIONS OF THE CITY OF CALIFORNIA AND COUNTY OF CONTRA COSTA.

B. IT IS INDEED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED.

C. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. A2.0LATEST EDITION) ARE A PART OF THESE CONTRACT DOCUMENTS.

D. DRAWINGS ARE BASED ON A SURVEY, DATED __________,20XX PREPARED BY"XXXX".

E. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS INTHE FIELD. ANY DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIOR TO STARTING WORK.

F. ALL PROPOSED SUBSTITUTIONS SHALL BE PROVIDED BY THE CMA PROJECTMANAGER, IN WRITING, PRIOR TO INSTALLATION.

G. ONLY THE BUILDING PLAN REVIEW FEE IS DUE AT SUBMITTAL, ALL OTHER FEESARE DUE AT THE TIME OF PERMIT ISSUANCE.

H. PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY-PERMITTEDDRAWING SET AT A TIME OF CONSTRUCTION.

I. ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACTARCHITECT IF ANY ABBREVIATIONS ARE NOT CLEAR.

J. G.C. SHALL SUPPLY AND INSTALL ALL ASPECTS OF THE PROJECT DESCRIBED INTHIS DRAWING SET UNLESS OTHERWISE NOTED.

K. GRAPHIC AND WRITTEN INFORMATION ON DRAWINGS SHALL BE COORDINATEDWITH ALL TRADES PRIOR TO INSTALLATION.

PROJECT DIRECTORY

OWNER:

XXX XXXX XXXX, LLC2415 SAN RAMON VALLEY BLVD,SAN RAMON, CA 94583

OWNER CONTACT:XXXX XXXX

ARCHITECT:XXXXXX XXXXXXXXX

PROJECT MANAGER:XXX XXX

LEGAL JURISDICTION: SAN RAMON COUNTY

CODE:

BUILDING: 2016 CALIFORNIA BUILDING CODECALIFORNIA CODE OF REGULATIONS TITLE 24

ACCESSIBILITY: 2016 CALIFORNIA BUILDING CODE CHAPTER 11BCALIFORNIA CODE OF REGULATIONS TITLE 24

MECHANICAL: 2016 CALIFORNIA MECHANICAL CODECALIFORNIA CODE OF REGULATIONS TITLE 24, PART 4

PLUMBING: 2016 CALIFORNIA ELECTRICAL CODECALIFORNIA CODE OF REGULATIONS TITLE 24, PART 5

ELECTRICAL: 2016 CALIFORNIA ELECTRICAL CODECALIFORNIA CODE OF REGULATIONS TITLE 24, PART 3

ENERGY: 2016 CALIFORNIA ENERGY CODECALIFORNIA CODE OF REGULATIONS TITLE 24, PART 6

FIRE: 2016 CALIFORNIA FIRE CODECALIFORNIA CODE OF REGULATIONS TITLE 24, PART 9

HEALTH: COUNTY OF SAN RAMON HEALTH SYSTEM

BUILDING AREA: XXXX SF

SEATING: INTERIOR - 66 SEATS

OCCUPANCY: A2

TYPE OFCONSTRUCTION: II-B

TOTAL OCCUPANTS: XXX

N

NORTH

N

N

BUILDING CODE CLASSIFICATION

COVER SHEET

T1.0

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

EMERGENCY LIGHTS & EXIT SIGNS

SECURITY ALARM & WIRING

STOCKROOM SHELVING

EQ

UIP

'T

SPEAKER WIRINGSOUND SYSTEM

LIGHT FIXTURES & LAMPS

MILLWORKFLOOR FIXTURES

SAFE

FIXT

UR

ES

INSTALL BY

GENERAL ELECTRICAL WIRING

CONCRETE FLOORING- SALES FLOOR

NEW PLUMBING LINES IN SPACEPLUMBING FIXTURES & ACCESSORIES

PLUMBING (WASTE, VENT & WATER) TO SPACEFIRE ALARM & EMERGENCY PAGING SYSTEMFIRE EXTINGUISHERS & CABINETSSPRINKLER LINES & HEADSSPRINKLER MAIN TO SPACE

MECHANICAL SUPPLY & RETURN DUCTING

MECHANICAL EQUIPMENT (UNITS)TELEPHONE TERMINATIONS

ELECTRIC WATER COOLER

VINYL BASEFLOOR TRANSITIONS

PAINT- SALES AREA

FIN

ISH

ES

MECHANICAL CONTROLS

ELECTRICAL SERVICE CONDUIT & WIRE TO SPACE

INTERIOR GRAPHICS & SIGNAGE

METAL DOORS AND FRAMESSTOREFRONT GLASS, & FRAMING

OTHER INTERIOR PARTITIONS & PREPDEMISING PARTITION GYPSUM BOARD & PREPDEMISING PARTITION: (METAL STUD/MASONRY)

ALL DOOR HARDWARE

STOREFRONT SIGNAGE

ASBESTOS REMOVALINSULATION

FLOOR LEVELING

FIRE PROOFING

TEN

AN

T G

.C.

TEN

AN

T

LAN

DLO

RD

TEN

AN

T

LAN

DLO

RD

FURNISH BY

TEN

AN

T G

.C.

REMARKS

MOP SINK

EXI

STI

NG

EXI

STI

NG

ELECTRICAL WIRING & RECEPTACLES

PAINT- DECK/ STEEL/ ETC

EMPLOYEE BREAK TABLE/SHELVINGMANAGER'S DESK/SHELVING

WALLPAPER

SECURITY MIRRORS / CAMERAS

FIXTURE ASSEMBLYSTOCK SHELVINGCORNER UNITS

UNIT HEATERS

FRP PANELS

TELEPHONE CONDUIT TO SPACE

CONCRETE FLOORING- STOCKROOM / MANAGERS OFFICETILE FLOORING

PAINT- RESTROOMS/ MANAGERS OFFICE/ STOCKRM

NOTES:1. WORK DESIGNATED BY L.L. IS LANDLORD

RESPONSIBILITY2. WORK DESIGNATED BY T.G.C. IS TENANT GENERAL

CONTRACTOR RESPONSIBILITY

3. WORK DESIGNATED BY TB IS TACO BELLRESPONSIBILITY

TELEPHONE WIRING

MECHANICAL THERMOSTATS

MODIFICATIONS/REPAIRS BY TENANT GC

AS REQUIRED

RELOCATION REPLACEMENT BY TGCMODIFICATIONS/REPAIRS BY TENANT GC

MODIFICATION BY TENANT GCRELOCATION BY TENANT GC

NEW BY TENANT GC

RELOCATION BY TENANT GC

RELOCATE EXISTING

NEW/ RELOCATE BY TENANT GCNEW/ RELOCATE BY TENANT GC

Page 2: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

48

"

60

"

72" 72"

1

1

2

3

3

3

3

3

3

3

3

2

4

5

5

6

6

12

8

16

8

8

12

7

3

9

2

2

2

2

WALK INCOOLER

SALES

WOMEN'SRR

MEN'SRR

DINING

BOH

BOH

WALK INFREEZER

KTICHEN

ADJACENT TENANT

CORR

IDO

R

EXTE

RIO

REXTERIOR

ADJA

CEN

T TE

NAN

T

15

15

15

13

14

14

11

8

10

CORRIDOR

N

BD3.0

AD3.0

8

16

DEMOLITION

FLOOR

PLAN

D1.0

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

EXISTING FLOOR TILE AND BASE TO BE REMOVED. PREP FOR NEW FLOOR TILEAND BASE TYP.

EXISTING FULL HEIGHT WALL TO BE REMOVED. PATCH AND REPAIR FLOOR TOTAKE UP NEW FINISHES.

ALL EXISTING FIXTURES AND FURNITURE TO BE REMOVED AND DISCARDED.

EXISITING ENTRANCE DOOR & ALL HARDWARE TO BE REMOVED.

EXISITING WALL FINISHES IN RESTROOM TO BE REMOVED. PREP FOR NEW WALLFINISHES.

EXISTING SANITARY FIXTURES AND TOILET EQUIPMENTS TO BE REMOVED.

EXISTING POS COUNTER AND EQUIPMENTS TO BE REMOVED AND DISCARDED.PREP FOR NEW COUNTER. CO-ORDINATE WITH FRANCHISSE FOR EQUIPMENTRETAINMENT.

EXISTING BOH EQUIPMENTS AND SHELVES TO BE RELOCATED AND REUSED.

EXISTING RAILING TO BE REMOVED AND DISCARDED. PATCH AND REPAIR FLOORTO TAKE UP NEW FINISHES.

REMOVE MENU BOARDS.

REMOVE KIOSK.

EXISITING DOOR TO BE REMOVED AND RELOCATED AS PER PLAN. SEE SHEET A1.1FOR NEW LOCATION.

STRUCTURAL COLUMN TO REMAIN.

EXTERIOR SIGNAGE TO BE REMOVED AND REPLACED WITH NEW.

BOH FLOORING TO REMAIN. PATCH AND REPAIR TO MATCH EXISTING WHEREVERMODIFIED.

EXISTING BOH EQUIPMENTS TO BE REMOVED.

1

2

3

4

5

6

7

8

9

ITEMS BEING DEMOLISHED.

EXISTING ITEMS.

A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITYOF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, G.C. TO NOTIFYARCHITECT OF RECORD IMMEDIATELY.

B. G.C RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULLSCOPE OF WORK.

C. PATCH AND REPAIR EXISTING WALLS TO REMAIN AS REQUIRED TO PROVIDE A SMOOTH,PAINT READY FINISH.

D. DEMOLISH EXISTING INTERIOR WALLS AND/OR WALL FINISHES AS DIRECTED.

E. IF CONTRACTOR ENCOUNTERS ANY HAZARDOUS MATERIALS DURING DEMOLITION ORCONSTRUCTION ,SHALL IMMEDIATELY SUSPEND WORK & NOTIFY HB CONSTRUCTIONMANAGER BEFORE PROCEEDING.

F. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER AND IN STRICTACCORDANCE WITH REGULATIONS.

G. REMOVE EXISTING LIGHT FIXTURES, EQUIPMENT AND POWER LINES AS DIRECTED.

H. REMOVE EXISTING PLUMBING FIXTURES AS DIRECTED. CAP LINES AS DIRECTED FORTHOSE NOT BEING RE-USED.

J. TENANT TO VERIFY EXISTING CONDITIONS BEFORE PROCEEDING WITH TENANTIMPROVEMENT WORK. IF ANY DISCREPANCY IS FOUND, TENANT TO NOTIFY LANDLORDIN WRITING.

K. ANY MODIFICATION / RELOCATION OF LANDLORD'S IMPROVEMENTS TOACCOMMODATE TENANT'S DESIGN SHALL BE TENANT'S RESPONSIBILITY.

L. VERIFY WITH OWNER ON STORAGE OR DISPOSAL OF ANY REUSABLE MATERIALS, SEEKEYNOTES AND PROJECT GENERAL NOTES FOR ADDITIONAL REQUIREMENTS.

DDEMOLITION FLOOR PLAN 1/4" = 1'-0" AKEY NOTES NTS

BLEGEND NTS

CGENERAL NOTES NTS

10

11

12

13

14

15

16

AutoCAD SHX Text
KIOSK
Page 3: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

48

"

60

"

72" 72"

L1

L1 L1

L1

L1

L1

L1 L1L1

L1

113

2

3

1

2

2

2

33

3

3

3

33

2

2 2

2

1

1

1

1

1

1

1

1

2

2

5

5

4

4

4

4

4

4

DEMOLITION

REFLECTED

CEILING PLAN

D2.0

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

DCONSTRUCTION FLOOR PLAN 1/4" = 1'-0" AKEY NOTES NTS

BLEGEND NTS

CGENERAL NOTES NTS

ITEMS BEING DEMOLISHED.

EXISTING ITEMS.

CEILING AND ASSOCIATED LIGHT FIXTURES TO BE REMOVED AND DISCARDED.PREPARE FOR NEW CEILING AND LIGHT FIXTURES.

EXISTING LIGHT FIXTURES TO BE REMOVED.

EXISTING SPRINKLERS TO REMAIN.

EXISTING VENTS TO BE REMOVED.

EXISTING CCTV CAMERAS TO BE REMOVED.

1

2

3

4

5

AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
Page 4: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

BDEMO EXTERIOR ELEVATION AT SIDE STOREFRONT 3/8" = 1'-0"

BDEMO EXTERIOR ELEVATION AT STOREFRONT MAIN ENTRANCE 3/8" = 1'-0"CKEY NOTES

DEMO

EXTERIOR

ELEVATIONS

D3.0

AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
13'-9" V.I.F.
AutoCAD SHX Text
ROOF LEVEL
AutoCAD SHX Text
19'-3" V.I.F.
AutoCAD SHX Text
T.O. PARAPET WALL
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
T.O. STOREFRONT GLAZING
AutoCAD SHX Text
LEASE LINE
AutoCAD SHX Text
LEASE LINE
AutoCAD SHX Text
13'-9" V.I.F.
AutoCAD SHX Text
ROOF LEVEL
AutoCAD SHX Text
19'-3" V.I.F.
AutoCAD SHX Text
T.O. PARAPET WALL
AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
T.O. STOREFRONT GLAZING
AutoCAD SHX Text
LEASE LINE
AutoCAD SHX Text
LEASE LINE
AutoCAD SHX Text
EXISTING GLASS DOOR WITH ALL HARDWARE TO BE REMOVED. EXISTING SIGNAGE TO BE REMOVED. ALL EXISTING MULLIONS TO BE CLEANED AND PREPARED TO TAKE NEW FINISH IF APPROVED BY L.L EXISTING FINISHES TO REMAIN.
Page 5: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

D

A

C

C

A

A

B

E

48

"

60

"

72" 72"

ADJACENT TENANT

CORR

IDO

R

BA6.0

11'-514"

7'-4

"

3'-0

"

7'-712"

2'-934"

6'-612"

5"

14'-1012" 7'-3"

714"

1'-1112"

A

3'-4

"

8'-712"

7'-7

1 2"3'

-0"

1114" 9'

-113 4"

7'-1014"

5'-6

1 2"3'

-01 4"

1'-1

3 4"

3'-0

1 4" R.O

3'-7

3 4"

8'-314"

4'-2

1 2"

5"5"

712"

5"

1

WALK INCOOLER

SALES

WOMEN'SRR

MEN'SRR

DINING

BOH

BOH

WALK INFREEZER

KTICHEN

XBOX GAMEROOM

2

4

4

5

AA6.0

BA6.1

AA6.1

3

BA7.0

AA7.0

4

4

EXTE

RIO

REXTERIOR

ADJA

CEN

T TE

NAN

T

5 5

5

5

7

5

CA6.2

AA6.2

DA6.2

BA6.2

6

14'-2

"

3'-614"

1

4

2

3

5

MAIN ENTRANCE

NEW GLAZINGTO MATCHEXISTING.

XAX.XX

CORRIDOR

EXISTING STUDCOLUMN TOREMAIN.

5

AA8.0

N

6

C

SIDE ENTRANCE

4'-234"

5'-6

1 2"

CONSTRUCTION

FLOOR

PLAN

A1.0

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

DCONSTRUCTION FLOOR PLAN 1/4" = 1'-0" AKEY NOTES NTS

BLEGEND NTS

CGENERAL NOTES NTS

LEASE LINE

LINE OF ROOF ABOVE.

EXISTING MOP SINK. REFER TO SHEET A2.0 & A2.1

S.S CORNER GUARD / WALL CAP, TYP. ALL CORNERS IN BACK-OF-HOUSE FROMREAR WALL TO THE KITCHEN SIDE OF THE SERVICE COUNTER.

LINE OF BULK HEAD ABOVE.

SPLASHGUARD.

CASED OPENING.

1

2

3

4

5

6

7

: DIMENSIONSA. ALL DIMENSIONS ARE TO FACE OF INTERIOR STUD U.O.N.B. DIMENSIONS NOTED AS "CLEAR" OR "HOLD" ARE MIN. REQ'D. NET CLEARANCE FROM

FACE OF WALL / WAINSCOT FINISH.C. VERIFY FINAL EQUIPMENT SIZES WITH VENDOR PRIOR TO INT. WALL FRAMING.

: WINDOWS / DOORSA. SEE SHT. A1.1 FOR WINDOW TYPES AND DOOR SCHEDULE.B. ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING.

: FINISH SUBSTRATESA. PROVIDE 1/2" THICK CEMENTITIOUS BD. FROM FLOOR SLAB TO 48" A.F.F. MIN. IN LIEU

OF GYP. BD. AT ALL WALLS EXCEPT SHEARWALL SURFACES, U.O.N.B. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES

SHALL BE SEALED WITH "NSF INTERNATIONAL" APPROVED SEALANTS.C. ALL BACK OF HOUSE AND OFFICE WALLS SHALL HAVE 1/2" CDX PLYWOOD

SUBSTRATE, U.O.N.

: DECORA. SEE A2.0 FOR FIXTURES, EQUIPMENTS & FURNITURE PLAN AND DETAILS.B. SEE A3.0 FOR FLOOR FINISHES.C. SEE A8.0 - A8.3 FOR WALL FINISHES.D. SEE A4.0 FOR CEILING FINISHES.E. SEE A7.0 FOR FINISH SCHEDULE.

: GENERALA. PROVIDE THREE FIRE EXTINGUISHERS - (2) 10 lb. BC and (1) 10 lb. ABC - TO COMPLY

WITH LOCAL FIRE CODE. LOCATE PER DIRECTION OF FIRE MARSHALL OR LOCALAUTHORIZING AGENT.

B. DRAWINGS BASED ON NEW CONSTRUCTION UTILIZING METAL STUD CONSTRUCTIONWITHIN EXISTING SPACE. G.C TO COORDINATE WITH BUILDING FACILITIES MANAGERFOR BUILDING STANDARDS, EXISTING CONDITION COORDINATION AND ANY OTHERBUILDING RULES AND REGULATIONS FOR CONSTRUCTION OPERATIONS ANDSCHEDULING. CONTRACTOR TO BE RESPONSIBLE FOR MAINTENANCE OF THEINTEGRITY OF ALL EXISTING FIRE RATED ASSEMBLIES AND FOR PATCHING ORREPAIRING OF ANY EXISTING FIRE RATED ASSEMBLIES DAMAGED DURINGCONSTRUCTION. PROVIDE METAL OR FIRE RETARDANT BLOCKING IN WALL ATLOCATIONS THAT HAVE WALL MOUNTED ACCESSORIES. COORDINATE WITH PLANS.

TYPICAL EXTERIOR WALL :8" DEMISING WALL.

INTERIOR SOUND RATED WALL :TYPICAL INTERIOR WALL W/ 3-1/2" UNFACEDFIBERGLASS SOUND BATT.

3 5/8" MTL. STUDS

6" MTL. STUDS

LOW HEIGHT WALL :

WALL SUBSTRATES :

DINING ROOM :1/2" GYPSUM WALLBOARD TO 6" ABOVE CEILING OR TO UNDERSIDE OF DECK WHEREEXPOSED.(NOTE: THE CEMENT BOARD SPECIFICATION IS DESIGNED TO ALLOW THE G.C.FLEXIBLITY. )

KITCHEN WALLS AND DINING ROOM CLOSET :1/2" CEMENT WALLBOARD FROM T.O. SLAB TO 12" AFF, USE 1/2" CDX PLYWOOD W/FRPSURFACE FINISH TO 6" ABOVE CEILING HT U.O.N.

RESTROOM WALLS :5/8" CEMENT WALLBOARD FROM T.O. SLAB TO 48" A.F.F. WITH 5/8" HI-IMPACT BRAND XPWALLBOARD, MOISTURE RESISTANT GYPSUM WALLBOARD FROM T.O. CEMENT BOARD TO6" ABOVE CEILING HEIGHT U.O.N. NO SUBSTITUTIONS ALLOWED. FINISH AS SCHEDULED.

ALL OTHER FRAME WALL CONDITIONS :1/2" CEMENT WALLBOARD FROM T.O. SLAB TO 48" A.F.F., WITH 1/2" GYPSUM WALLBOARDFROM T.O. CEMENT BOARD TO 6" ABOVE CEILING HEIGHT U.O.N. FINISH AS SCHEDULED.

EXISTING STUD COLUMN

TYPICAL INTERIOR WALL :3-5/8" MTL STUDS AT 16" 0.C. INTERIORWALLS AND GYPSUM BOARD. SEPARATINGDINING SPACE WITH OTHER AREAS TOEXTEND TO UNDERSIDE OF TRUSSES U.O.N.

3 5/8" MTL. STUDS

6" MTL. STUDS

C

D

A

B

NOTE:PARTITION TO HAVE PLYWOOD BACKING TO SUPPORTALL ARTWORK AT LOCATIONS SPECIFIED AND TV'SMOUNTED ON PARTITION WALLS.

Page 6: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

3'-5" V.I.F

7'-1

" V

.I.F

2'-0

" V

.I.F

6'-1

0"

0'-1"0'-1"

2'-11"

3'-0"

7'-2

"

0'-2"0'-2"

3'-0"

3'-4"

DOOR

NO.ROOM NAME QTY.

DOOR SIZE

TYPE

DOOR

MATERIAL

FRAME

MATERIAL

BUTTS LOCKS CLOSERS KICKPLATE THRESHOLD DOOR STOP MISCELLANEOUS

DOOR NOTES

WIDTH HEIGHT THICKNESS

ON

E P

AIR

O

FF

SE

T P

IV

OT

S P

ER

D

R. M

FR

., T

OP

&

B

TM

1 1

/2

P

R M

cK

IN

NE

Y #

TA

27

14

, 4

-1

/2

" x 4

-1

/2

" U

S2

6D

CO

NT

. H

IN

GE

IN

CL

UD

ED

IN

P

AC

KA

GE

H.D

. T

YP

E 3

04

S

.S

. B

OB

RIC

K S

PR

IN

G L

OA

DE

D

YA

LE

B

-P

B5

40

5L

N S

TO

RE

RO

OM

/C

LO

SE

T L

OC

K

FU

LL

L

EN

GT

H L

AT

CH

P

RO

TE

CT

OR

IN

CL

. IN

P

KG

.

PA

NIC

H

AR

DW

AR

E IN

CL

UD

ED

IN

P

AC

KA

GE

FA

LC

ON

C

95

3-7

O

R C

98

7-7

A

S R

EQ

UIR

ED

FA

LC

ON

"T

" S

ER

IE

S - P

RIV

AC

Y S

ET

FA

LC

ON

1

69

0 C

ON

CE

AL

V

ER

T. P

AN

IC

H

AR

DW

AR

E

CL

OS

ER

IN

CL

UD

ED

IN

P

AC

KA

GE

DO

RM

A 7

41

4 A

RP

S

NB

6

89

ST

AIN

LE

SS

S

TE

EL

1

0" x .0

50

X

2

" L

.T

.D

.W

.*

KIC

KP

LA

TE

IN

CL

UD

ED

IN

P

AC

KA

GE

AC

CE

SS

IB

LE

A

LU

M. T

HR

ES

HO

LD

B

Y D

OO

R M

FR

.

TH

RE

SH

OL

D IN

CL

UD

ED

IN

P

AC

KA

GE

HIN

GE

S

TO

P - R

OC

KW

OO

D 5

32

.N

P

XC

LU

DE

R P

ES

T C

ON

TR

OL

D

OO

R S

WE

EP

#

16

25

00

SW

EE

P (V

IS

TA

2

31

S

TD

) N

GP

1

01

VA

UN

DE

RC

UT

3

/4

"

PR

OV

ID

E A

S

IG

N S

TA

TIN

G"T

HIS

D

OO

R T

O R

EM

AIN

CO

AT

H

OO

K - B

OB

RIC

K

DO

OR

S

IG

N

1 DINING 1 6' - 5" 9' - 9" A AL/GLASS AL

2 WOMENS 1 3' - 0" 0' - 1 3/4" B WD HM X X X X X X X X 1, 3, 4, 5, 8, 9, 10

3 MENS 1 3' - 0" 7' - 2" 0' - 1 3/4" B WD HM

4 GAMES 1

5 BOH 1 3' - 0" 6' - 10" 0' - 1 3/4" D HM HM

CSTOREFRONT

UN

LO

CK

ED

D

UR

IN

G B

US

IN

ES

S H

OU

RS

"

6

0' - 2"

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

DINING 21

7' - 2"

BSTOREFRONT

DOOR AND

WINDOW

SCHEDULE

A1.1

EDOOR SCHEDULENOTES NTS

CDOOR SCHEDULE NTS

DGENERAL DOOR & WINDOW NOTES NTS ASTOREFRONT TYPES 3/8 = 1'-0"

BDOOR TYPES 3/8 = 1'-0"

INTERIOR DOORS, FRAMES & HARDWARE

LOCKNET

800 JOHN C WATTS DriveNICHOLASVILLE, KY 40356800-887-4307 FAX : [email protected]

NOTE:SHADING COEFFICIENT SPECIFICATION PER LOCAL CODEREQUIREMENTS. DAYTIME VISIBILITY INTO DINING ROOM SHALL BEMAINTAINED.

**** ALL STOREFRONT GLAZING SHALL BE LOW "E" SOLAR GLASS ****

1" INSULATED GLASS BA 1" INSULATED TEMPERED GLASS

GLASS SCHEDULE

NATIONAL ACCOUNT SUPPLIER

GREEN

HAMILTON PARKER HEADQUARTERS

JIM CAMPBELL1865 LEONARD AVENUECOLUMBUS, OHIO 43219614-358-7806 FAX : [email protected]

1. DIMENSIONS ON THIS DWG. ARE TO FRAME EDGE. REFER TO SHEET A1.0 FOR ROUGHOPENING DIMENSIONS.

2. ALL STOREFRONT FRAMES TO MATCH EXISTING.3. SEE SCHEDULE FOR GLASS TYPES.4. REFER TO FLOOR PLAN, ELEVATIONS AND WALL SECTIONS FOR ROUGH OPENING

DIMENSIONS.5. ALL STOREFRONT MATERIAL AND GLAZING SHALL BE SUPPLIED AND INSTALLED BY G.C.

U.O.N.6. PROVIDE PUSH/ PULL PLATES. IF REQUIRED BY LOCAL CODE, STOREFRONT DOOR PANIC

HARDWARESHALL BE : DOR-O-MATIC 2092 RIM PANIC HARDWARE AND EXTERIOR PULLS WITHQUALITY #520 DOOR PULL.

7. LAMINATE DOORS AND PAINT FRAMES. SEE FINISH SCHEDULE, SHEET A7.2.8. PERMANENT CORES SHALL BE SHIPPED TO THE RESTAURANT GENERAL MANAGER.9. MAXIMUM DOOR OPERATING PRESSURE : 5 LBS INTERIOR : 15 LBS EXTERIOR.10. FIELD VERIFY EXISTING STOREFRONT DIMENSIONS BEFORE REPLACING/INSTALLING DOORS /

STOREFRONT SYSTEMS.

CDOOR

DDOOR

1. MOUNT DOOR CLOSERS ON RESTROOM OR KITCHEN SIDE ONLY.

2. LOCKNET SECURITY DOOR. COMPLETE DOOR, FRAME, AND HARDWARE PACKAGE PROVIDEDBY RSCS. FACILITIES CONNECTIONS.

3. MOUNT KICKPLATE ON PUSH SIDE ONLY.

4. ADA COMPLIANT ACCESSIBILITY SIGNAGE WHERE REQUIRED (OR AS REQUIRED BY LOCALJURISDICTION) - (1) MEN; (1) WOMEN

5. RESTROOM SIGN REQUIRED.

6. PROVIDE LATCH AND STRIKE PLATE HARDWARE BY DOOR MFR. TO BE COMPATIBLE WITHLOCK.

7. PROVIDE PUSH/PULL PLATES. IF REQUIRED BY LOCAL CODE, STOREFRONT DOOR PANICHARDWARE SHALL BE: DOR-O-MATIC 2092 RIM PANIC HARDWARE AND EXTERIOR PULLS WITHQUALITY #520 DOOR PULL.

8. LAMINATE RESTROOM DOORS. REFER TO A7.2 FOR FINISHES.

9. OPTIONAL HARDWARE AT RESTROOM DOOROCCUPANCY INDICATOR DEADBOLT: FALCON D271PUSH PLATE: ROCKWOOD 70F - 8"X16"PULL PLATE: TRIMCO 1017-3B - 4"X16"

10. PROVIDE RESTROOM DOOR SIGNAGE. REFER A8.3 FOR DETAILS.

11. LAMINATE DOORS 4, 5, 6 & 7 AND PAINT FRAMES 3, 4, 5, 6 & 7. SEE FINISH SCHEDULE, SHEETA7.2.

12. ALL HARDWARE SHALL BE US32D U.O.N.

13. ALL HM FRAMES SHALL BE 16 GA STEEL U.O.N.

14. ALL LOCKS SHALL BE FALCON 6 PIN INTERCHANGEABLE CORE SUPPLIED AND INSTALLED BYTHE G.C. ALL EXTERIOR LOCKS SHALL BE PROVIDED WITH CONSTRUCTION CORES. ALLPERMANENT CORES SHALL BE KEYED ALIKE.

15. INSTALL WITH APPLIED DOOR STOPS AND WEATHER STRIPS.

16. FRAMES SHALL BE PAINTED.

17. RESTROOM PARTITIONS : BOBRICK 1080 SERIES, WITH STAINLESS STL. 1 1/2" WALL POST,LATCH , KEEPER, COAT HOOK (DTL 20/ADA1.0) & MOUNTING BRACKETS. INSTALL PERMANUFACTURER'S SPECIFICATIONS & DETAILS. DOOR HANDLE AND LATCH SHALL BEMOUNTED AT 36" A.F.F.

18. PROVIDE LATCH AND STRIKE PLATE HARDWARE BY DOOR MFR. TO BE COMPATIBLE WITHLOCK.

19. PROVIDE 2" REMOVABLE ASTRAGAL FROM INSIDE ONLY.

20. GC TO TRIM DOOR SWEEP TO FIT DOOR.

REMARKS

EXISTING TO REMAIN

EXISTING DOOR TO BE RELOCATED

EXISTING TO REMAIN

EXISTING TO REMAINA3' - 0" 9' - 9" AL/GLASS AL0' - 2"

TBD TBD TBDTBDTBDTBD

Page 7: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

72

"

R

A

S

T

R

A

S

H

WALK INCOOLER

SALES

WOMEN'SRR

MEN'SRR

DINING

BOH

BOH

WALK INFREEZER

KITCHEN

XBOX GAMEROOM

MERCHVENDING

CORR

IDO

R

EXTE

RIO

R

ADJA

CEN

T TE

NAN

T

EXIT 1EXIT SIGN, SEEAX.0 FORDETAILS, TYP.

EXIT 2

EXIT SIGN, SEEAX.0 FORDETAILS, TYP.

3'-0

"6'-01

4"

BOH TO EGRESS BACK DOOR

EXIT PATH TRAVEL DISTANCE= 51'-4 12"

WALK IN COOLER TO BACK DOOR

EXIT PATH TRAVEL DISTANCE= 44'-6 12"

KIT

CH

EN

TO

FR

ON

T D

OO

R

EXI

T P

ATH

TR

AVE

L D

ISTA

NC

E=

67'

-3 7 8"

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

EGRESS PLAN

A1.2

Page 8: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

72

"

R

A

S

T

R

A

S

H

WALK INCOOLER

SALES

WOMEN'SRR

MEN'SRR

DINING

BOH

BOH

WALK INFREEZER

KITCHEN

XBOX GAMEROOM

MERCHVENDING

K-512

S-580

K-525

N-208B-405B-599N-071

F-021

U-039F-026

F-060F-102F-050

F-080F-131S-489

F-040F-090F-014

F-270

K-497

B-290N-062

N-056

P-315

K-602

C-107

C-079

S-540S-550

S-544

S-375

U-070 (3)

U-100 (3)F-090 (3)U-152 (3)F-165 (3)

U-061 (3)

C-254

U-20XU-238

C-203C-203

U-20XU-238

U-20XU-238

U-20XU-238

U-250U-209

U-250U-209

S-117S-117

P-XX1P-XX1

K-XX1

S-130S-127S-129

T-6196

T-622B

S-284 T-623 T-707

N-043

ADJACENT TENANT

CORR

IDO

R

EXTE

RIO

REXTERIOR

ADJA

CEN

T TE

NAN

T1

4

3

5

5

XXX

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

K-497

3

CORRIDOR

PARTITION TO HAVE PLYWOODBACKING TO SUPPORT ALLARTWORK AT LOCATIONSSPECIFIED AND TV'S MOUNTEDON PARTITION WALLS.

NOTE:PARTITION TO HAVE PLYWOOD BACKING TO SUPPORTALL ARTWORK AT LOCATIONS SPECIFIED AND TV'SMOUNTED ON PARTITION WALLS.

N

BA6.0

AA6.0

BA6.1

AA6.1

BA7.0

AA7.0

CA6.2

AA6.2

DA6.2

BA6.2

(E)

(E)

(E)

(E)

(R)

(E)

(R)

(R)

(R)

(R) (R)

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

DEQUIPMENT PLAN & SCHEDULE 1/4" = 1'-0" AKEY NOTES NTS

BFURNITURESCHEDULE NTS

CGENERAL NOTES NTS

EQUIPMENT PLAN

& FURNITURE

SCHEDULE

A2.0

HOOD FIRE SUPPRESSION SYSTEM (ANSUL R-102 OR EQUAL). EXISTING TO

REMAIN.

MAINTAIN 42" MIN CLEAR ACCESSIBLE AISLE, 32" AT DOORWAY AND CASED

OPENINGS.

SPLASH GAURD.

SAFE BENEATH COUNTER.

ELECTRIC PANELS, REFER TO ELECTRICAL SHEETS.

1

2

3

4

5

1. REFER SHEET A2.1 FOR EQUIPMENT AND FURNITURE SCHEDULE.

Page 9: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

FURNITURE &

EQUIPMENT

SCHEDULE

A2.1

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

AEQUIPMENT SCHEDULE NTS

Page 10: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

ADJACENT TENANT

CORR

IDO

R

WALK INCOOLER

SALES

WOMEN'SRR

MEN'SRR

DINING

BOH

BOHWALK INFREEZER

KITCHEN

XBOX GAMEROOM

T-05B-02

3

4

7

T-05

T-05B-02

7

5

T-05B-02

7

9

EXTERIOR

ADJA

CEN

T TE

NAN

T

8

EQ EQ

15

N

11

11

11

XAX.XX

XAX.XX

2

10

CORRIDOR

XAX.XX

MAIN ENTRANCE

SIDE ENTRANCE

1 1

1213

14

15

6

6

6

6

6

6

B-02

WT-02

WT-03

WT-03

WT-03

WT-02

6

6

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

FLOOR FINISH

PLAN

A3.0

DFLOOR FINISH PLAN 1/4" = 1'-0" AKEY NOTES NTS

BLEGEND NTS

CGENERAL NOTES NTS

1

2

3

4

5

6

7

8

9

10

EXISTING FLOORING TO REMAIN. PATCH AND REPAIR FLOOR AS NEEDED.CONSULT WITH GC.

SAFE. COORDINATE THE LOCATION WITH CONSTRUCTION MANAGER.

START POINT FOR DINING TILE, CENTER ON DOOR. INSTALL FULL TILE ATTHRESHOLD.

TILE AND BASE TO CONTINUE UNDER MILLWORK COUNTER TOP.

TILE BASE ON TILE FLOOR.

WALL TILE TRANSITIONS DIRECTLY TO TILE FLOOR.

RESTROOM WALL TILE TRANSITIONS TO TILE FLOOR. SEE DETAIL XX/AX.X.

FLOAT FLOOR TILE FOR FLUSH TRANSITIONS.

ALIGN FLOOR TILE TRANSITION W/ FACE OF WALL.

BASE TILE TRANSITION.

FLOOR DRAIN.

FLOOR SINK.

NEW FLOOR DRAIN AS REQUIRED FOR NEW SINK. REFER PLUMBING DRAWINGS.

MOP SINK.

LEASE LINE.

11

12

T-XX

B-XX

WT-XX

TILE FINISH : SEE FINISH SCHEDULE FOR INFORMATION.

BASE TILE FINISH : SEE FINISH SCHEDULE FOR INFORMATION.

RESTROOM WALL TILE FINISH : SEE FINISH SCHEDULE FOR INFORMATION.

FLOOR DRAIN

NOTE :- REFER TO SHEET A8.0 FOR FINISH LEGEND AND ROOM FINISH SCHEDULE

A. DENOTES FINISH MATERIAL. REFER TO SHT A7.2 FOR FINISHES.

B. TILE JOINTS (U.O.N.):1. QUARRY FLOOR TILE : 1/4"2. PORCELAIN FLOOR TILE : 3/16"3. GLAZED WALL TILE : 1/8"4. BASE, TRIM AND ACCESSORIES : MATCH ADJOINING TILE UNITS

C. TILE INSTALLATIONS REQUIRE MANUFACTURERS STANDARD MOLDED CORNERS ATBOTH INSIDE AND OUTSIDE CORNERS.

D. ALL BASE TILE SHALL BE SANITARY COVE STYLE WITH 3/8" MIN RADIUS UNLESS NOTEDOTHERWISE.

E. SEE SCOPE OF WORK SHEETS FOR RESPONSIBILITIES.

F. PROVIDE CLEAR SILICONE CAULK WHERE FRP STOPS AT TOP OF COVE BASE.

G. TILE CHIPPING AROUND CORE DRILL HOLES FOR SEATING FIXTURE WILL NOT BEACCEPTED.

13

14

15

Page 11: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

72

"

R

A

S

T

R

A

S

H

REFLECTED

CEILING

PLAN

A4.0

BREFLECTED CEILING PLAN 1/2" = 1'-0" AREFLECTED CEILING SCHEDULE N.T.S.

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

AutoCAD SHX Text
10'-10" (FOH)/ 8'-4" (BOH)
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
HVAC DOWN THROW SUPPLY DIFFUSERS
AutoCAD SHX Text
HVAC RETURN AIR DIFFUSERS
AutoCAD SHX Text
10'-10" (FOH)/ 8'-4" (BOH)
AutoCAD SHX Text
EXIT SIGN
AutoCAD SHX Text
CEILING MOUNT SPEAKER
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
MOUNTED HEIGHT @A.F.F.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
2' X 4' DIRECT/ INDIRECT
AutoCAD SHX Text
S = FIRE SPRINKLER
AutoCAD SHX Text
CAMERA
AutoCAD SHX Text
SPECIFICATIONS
AutoCAD SHX Text
2' X 4' LIGHT FIXTURES
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
1' X 4' LIGHT FIXTURES
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
4' FLORECENT LIGHT FIXTURES
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
REFLECTED CEILING SCHEDULE
Page 12: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

RTU88 12" X 58 12"

1

ROOFEQUIP

DRAIN

SLOPESLOPE

RTU88 12" X 58 12"

2

3

ROOFEQUIP5

ROOFEQUIP

4

ROOFEQUIP

6

7 8

ROOFEQUIP

ROOFEQUIP

9

VENT PIPE

ROOFEQUIP

11

ROOFEQUIP

10

12'-11"

15'-112"12'-1"

29'-9

"

1'-10"

35'-1

"

6'-2

"10

'-6"

11'-8

"

7'-3"

7'-9

"

4'-8"

3'-6"

10'-10"

DRAIN

SLOPE

DISHANTENNA

PARAPET WALL

PARAPET WALL

SLOPE

SLOPE

SLO

PE

SLOPE

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

DROOF PLAN 1/4" = 1'-0" ANOT USED NTS

BNOT USED NTS

CROOFSCHEDULE NTS

ROOF PLAN

A5.0

AutoCAD SHX Text
SLOPE
Page 13: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

SIDE ENTRANCE DOOR

DINING DININGMEN'SRESTROOM

P-08

T-03

P-08

(E) MAINENTRANCE DOOR

DINING DINING

P-08 P-08 P-08

(N) GLAZING TO MATCHEXISTING

6'-8

" A.F

.F.

MIN

.

10" AXIOM TRIM

NO SMOKING SIGN

INSTALL PIN MOUNTED EXIT SIGN. REFERENCE ELECTRICAL SHEETS FOR HEIGHT.

1"x4" CHAIR RAIL/ WOOD TRIM.

WALL TILE TO GYP. TRANSITION.

PARTIAL HEIGHT WALL WITH SS CAP.

METAL TRIM AT SEAMS OF WAINSCOT. ALL SEAMS @ 4'-0" O.C.

ARTWORK/ MURAL WALL AND 1x1 TRIM SURROUND. REFER TO ARTWORK CATALOG FOR ARTWORK/MURAL SELECTIONS AND OPTIONS. CATALOG CAN BE DOWNLOADED FROM TACOBELLPLANS.COM

SS CORNER/ END WALL CHANNEL GUARD, FULL HEIGHT.

1

2

3

4

5

6

7

8

9

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

BINTERIOR ELEVATIONS - MAIN ENTRANCE 3/8" = 1'-0"

AINTERIOR ELEVATIONS - DINING 3/8" = 1'-0"

CKEY NOTES NTS

INTERIOR

ELEVATIONS

@ DINING

A6.0

AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
B.O. SOFFIT
AutoCAD SHX Text
8'-3" V.I.F.
AutoCAD SHX Text
B.O. CEILING
AutoCAD SHX Text
10'-10" V.I.F.
AutoCAD SHX Text
B.O. CEILING
AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
B.O. SOFFIT
AutoCAD SHX Text
10'-10" V.I.F.
AutoCAD SHX Text
B.O. CEILING
Page 14: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

COUNTER

DINING

SALES

P-08 P-08

P-02

B-02

T-02 FRP-01

GAME ROOM KITCHEN

B-02 B-01

TELEVISION TELEVISION TELEVISION

WC-01

CR-01

RESTROOM DOOR

KITCHENBEYOND

P-08

P-02

P-08

9

S-01 B-02

WC-01

CR-01

GAME ROOM

T-02

TRASHENCLOSURE

P-02SS-1

DR-43

L-02

T-02

TELEVISION TELEVISION

L-02 L-02 L-02

S-01

MT-02

L-02

SELFSERVESODA

10" AXIOM TRIM

NO SMOKING SIGN

INSTALL PIN MOUNTED EXIT SIGN. REFERENCE ELECTRICAL SHEETS FOR HEIGHT.

1"x4" CHAIR RAIL/ WOOD TRIM.

WALL TILE TO GYP. TRANSITION.

PARTIAL HEIGHT WALL WITH SS CAP.

METAL TRIM AT SEAMS OF WAINSCOT. ALL SEAMS @ 4'-0" O.C.

ARTWORK/ MURAL WALL AND 1x1 TRIM SURROUND. REFER TO ARTWORK CATALOG FOR ARTWORK/MURAL SELECTIONS AND OPTIONS. CATALOG CAN BE DOWNLOADED FROM TACOBELLPLANS.COM

SS CORNER/ END WALL CHANNEL GUARD, FULL HEIGHT.

1

2

3

4

5

6

7

8

9

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

CKEY NOTES NTS BINTERIOR ELEVATIONS - DINING 3/8" = 1'-0"

AINTERIOR ELEVATIONS - SALES/COUNTER 3/8" = 1'-0"

INTERIOR

ELEVATIONS

@ DINING

A6.1

AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
10'-10" V.I.F.
AutoCAD SHX Text
B.O. CEILING
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
B.O. SOFFIT
AutoCAD SHX Text
7'-0" V.I.F.
AutoCAD SHX Text
B.O. BULKHEAD
AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
B.O. SOFFIT
AutoCAD SHX Text
7'-0" V.I.F.
AutoCAD SHX Text
B.O. BULKHEAD
AutoCAD SHX Text
10'-10" V.I.F.
AutoCAD SHX Text
B.O. CEILING
Page 15: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

WALK-INCOOLER

TABLE

HEATEDCABINETS

FREEZER

FRP-08

B-1 B-1

13

1

2

B-1

FRP-08

13

OPENBEYOND

CO2 CYLINDER

B-1

FRP-08 FRP-08

B-1B-1

13

FRP-08 FRP-08FRP-08

OPENBEYOND

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

INTERIOR

ELEVATIONS @

BOH / KITCHEN

A6.2

EKEY NOTES NTS BBOH ELEVATION - 1 3/8" = 1'-0"DBOH ELEVATION - 3 3/8" = 1'-0"

ABOH ELEVATION - 2 3/8" = 1'-0"CBOH ELEVATION - 4 3/8" = 1'-0"

SS PANEL HOOD BEHIND.

J-BOX AND OUTLET INCLUDED WITH HOOD. INSET WITH FLUSH WITH FACE OF HOOD.

SHELF BY G.C. FINISH WITH PLASTIC LAMINATE L-10.

12" PHONE DISTRIBUTION BOX. OWNER PROVIDED AND INSTALLED.

SS CHASE FOR SYRUP LINES & ICE MACHINE REFRIGERANT LINES.

SMOKE DETECTOR WITH RESET SWITCH.

6" HIGH WATER HEATER PLATFORM.

ALERT LIGHT BOX FOR 3 COMP. POWER SOAK.

NO SMOKING SIGN

TECH-IN-BOX. TO PROVIDE BLOCKING WHERE REQUIRED.

WIRING CABINET BY POS PROVIDER.

TELEPHONE TERMINAL BOARD.

SS CORNER/ END WALL CHANNEL, FULL HEIGHT.

1

2

3

4

5

6

7

8

9

10

11

12

13

AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
10'-10" V.I.F.
AutoCAD SHX Text
B.O. CEILING
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
B.O. SOFFIT
AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
10'-10" V.I.F.
AutoCAD SHX Text
B.O. CEILING
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
B.O. SOFFIT
AutoCAD SHX Text
7'-0" V.I.F.
AutoCAD SHX Text
B.O. BULKHEAD
AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
10'-10" V.I.F.
AutoCAD SHX Text
B.O. CEILING
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
B.O. SOFFIT
AutoCAD SHX Text
7'-0" V.I.F.
AutoCAD SHX Text
B.O. BULKHEAD
AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
10'-10" V.I.F.
AutoCAD SHX Text
B.O. CEILING
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
B.O. SOFFIT
Page 16: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

AEXTERIOR ELEVATION AT SIDE STOREFRONT 3/8" = 1'-0"

BEXTERIOR ELEVATION AT MAIN STOREFRONT ENTRANCE 3/8" = 1'-0"CKEY NOTES NTS

DGENERAL ELEV.NOTES NTS

EXTERIOR

ELEVATIONS

A6.0

AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
13'-9" V.I.F.
AutoCAD SHX Text
ROOF LEVEL
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
T.O. STOREFRONT GLAZING
AutoCAD SHX Text
19'-3" V.I.F.
AutoCAD SHX Text
T.O. PARAPET WALL
AutoCAD SHX Text
LEASE LINE
AutoCAD SHX Text
LEASE LINE
AutoCAD SHX Text
(N) TB SIGNAGE MEDIUM BLACK DAY/WHITE NIGHT LINEAR 8'-6"W X 14"H TO BE PLACED CENTERED WITH ENTRANCE DOOR.
AutoCAD SHX Text
(N) BELL SIGNAGE V-04.3034 (3'-4"W X 3'-0"H
AutoCAD SHX Text
X
AutoCAD SHX Text
AX.X
AutoCAD SHX Text
(E) MAIN ENTRANCE DOOR
AutoCAD SHX Text
CL
AutoCAD SHX Text
13'-9" V.I.F.
AutoCAD SHX Text
ROOF LEVEL
AutoCAD SHX Text
19'-3" V.I.F.
AutoCAD SHX Text
T.O. PARAPET WALL
AutoCAD SHX Text
0'-0" V.I.F.
AutoCAD SHX Text
FLOOR FINISH LVL.
AutoCAD SHX Text
9'-9" V.I.F.
AutoCAD SHX Text
T.O. STOREFRONT GLAZING
AutoCAD SHX Text
(E) SIDE ENTRANCE DOOR
AutoCAD SHX Text
LEASE LINE
AutoCAD SHX Text
LEASE LINE
AutoCAD SHX Text
(N) TB SIGNAGE MEDIUM BLACK DAY/WHITE NIGHT LINEAR 8'-6"W X 14"H.
AutoCAD SHX Text
BUILDING SIGN BY SIGN VENDOR, REQUIRES ELECTRICAL. REF. ELECTRICAL SHEETS. EXISTING EXTERIOR FINISHES TO REMAIN. NEW GLAZING TO MATCH EXISTING.
AutoCAD SHX Text
MISCELLANEOUS: A. SEE SHT. A1.1 WINDOW TYPES FOR WINDOW ELEVATIONS. SEE SHT. A1.1 WINDOW TYPES FOR WINDOW ELEVATIONS. B. SEE SHT. A1.1 DOOR TYPES FOR DOOR ELEVATIONS. SEE SHT. A1.1 DOOR TYPES FOR DOOR ELEVATIONS. SEALERS (REFER TO SPECS): A. SEALANT AT ALL WALL AND ROOF PENETRATIONS. SEALANT AT ALL WALL AND ROOF PENETRATIONS. B. SEALANT AT WINDOW AND DOOR FRAMES AT HEAD AND JAMB. DO SEALANT AT WINDOW AND DOOR FRAMES AT HEAD AND JAMB. DO NOT SEAL SILL @ WINDOWS. C. APPLY NEOPRENE GASKET (CONT.) BETWEEN BUILDING & CANOPY. APPLY NEOPRENE GASKET (CONT.) BETWEEN BUILDING & CANOPY. "CRITICAL" DIMENSIONS: A. REQUIRED CLEAR OPENING WIDTH TO ENSURE COORDINATION WITH REQUIRED CLEAR OPENING WIDTH TO ENSURE COORDINATION WITH STANDARD SIGNAGE/ BUILDING ELEMENTS DIMENSIONS. NOTE: NO EXTERIOR SIGNS ARE WITHIN SCOPE OF WORK COVERED BY THE BUILDING PERMIT APPLICATION. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF THE INSTALLATION OF ALL EXTERIOR SIGNS AND INSTALLATION OF REQUIRED BLOCKING AND ELECTRICAL CONNECTIONS FOR FINAL APPROVED SIGNS.
Page 17: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

ANODIZED ALUM.WINDOW FRAME

20 GA. S.S. WALL GUARD -TOP OF SILL TO BOTTOMOF CLG. - ATTACH W/CONST. ADHESIVE

CAULK JOINT

HOLD 3/ 8"SPACE FORBACKER ROD

BLUESKIN VP WATERRESISTIVE AIRBARRIER MEMBRANEOVER PLYWOODSHEATHING

3-1/2" FIBER CEMENTBOARD TRIM

EXTERIOR

INTERIOR

FIBER CEMENT PANEL

2X4 WOOD STUDS

FIBER CEMENTPANEL CLIP

DOUBLE FLANGESEALANT BACKERAND SEALANT

SILLPLYWOODSHEATHING

SUBSTRATE-SEE SHEET A1.0

ANODIZED ALUMINUMWINDOW FRAME - SEEWINDOW SCHEDULE.

YAW

404

BACKER RODAND SEALANT

HOLD 3/ 8" SPACE FORBACKER ROD

BREAK METALTO MATCHSTOREFRONT

(3) 2X6SEE STRUCTURALDRAWINGS

OVER BUILDING PAPEROVER 1/2" PLYWOOD

NOTE: SEE DETAIL 16/A6.1 FOR ADDITIONAL INFORMATION REGARDING WATERPROOFING AT AND NEAR WINDOWS / DOORS

EXTERIORB

INTERIORB

ANODIZED ALUMINUMWINDOW FRAME - SEEWINDOW SCHEDULE.ALIGN FRAME WITHFACE OF SEATHING

R.O.

BLUESKIN VP WATERRESISTIVE AIR BARRIERMEMBRANE O/ PLYWOOD

3 /8" SHIM

LAG BOLT& WASHER

MTL "Z" FLASHING W/ ENDDAM - NO SEALANT ATFLASHING TO ALLOWWEEPAGE WITHIN FRAME

312"

3-1/2" FIBER CEMENTBOARD TRIMCAULKING

INTERIOR

B

EXTERIORB

B

FIBER CEMENT PANEL

SPACER

HEADER -SEESTRUCTURAL

FIBER CEMENT PANELS

ANODIZED ALUMINUM WINDOWFRAME - SEE WINDOW SCHEDULE.ALIGN FRAME WITH FACE OFSEATHING

R.O.

3/8" SHIM3/8" BACKER ROD &SILICONE

STOREFRONTBACK PLATETO SUPPORTSHIM

CONT. SOFFIT VENT W/INSECT SCREEN

SEE INT.ELEVATIONSFOR FINISH

Z- FLASHING

3-1/2" FIBER CEMENTBOARD TRIM

STARTER STRIP

BLUESKIN VP WATERRESISTIVE AIR BARRIERMEMBRANE O/ PLYWOOD

INTERIOR

B

EXTERIORB

B

P.T. 2X4 WOOD STUDS

PLYWOOD SHEATHING

2x FRAMING

FIBER CEMENT PANEL CLIP

FIBER CEMENTPANEL SYSTEM

J-TRIM

EXTERIORB

INTERIOR

B

SERVICE DOOR -SEE DOORSCHEDULE ANDSCOPE OF WORK

ADA COMPLIANTALUMINUMTHRESHOLD -SET IN SEALANT

NOTE:SEE FLOOR FINISHPLAN FOR FLOORFINISHES

FINISH FLOOROVER CONCRETESLAB

PRE-MOLDEDEXPANSION JOINT

1 2" MA

X.

INTERIOR

B

EXTERIOR

B

SERVICE DOOR - SEE DOORSCHEDULE - ALIGN FRAMEWITH FACE OF SHEATHING

SEALANT &BACKER ROD

3/8" SHIM,LAG BOLT &WASHER

4" @

HE

AD

2" @

JA

MB

HEADER - SEESTRUCTURAL

1/2" GYP.BOARD

FIBER CEMENT PANEL

STARTER TRACK

FLASHING PAINT TOMATCH WALL FINISH

FIBER CEMENTPANEL SYSTEM

BLUESKIN VP WATERRESISTIVE AIR BARRIERMEMBRANE OVERPLYWOOD SHEATHING

B

INTERIOR

B

EXTERIORB

B

ANODIZED ALUM.WINDOW FRAME WEEPHOLES

SILL RECEPTOR W/FASTENER

3/8" SETTING BED

EXPANSION FILLER

SIDEWALK

NOTE: SEE DETAIL 16/A6.1 FOR ADDITIONAL INFORMATION REGARDING WATERPROOFING AT AND NEAR WINDOWS / DOORS

ALIGN AS SHOWN WITHEDGE OF SLAB

6"

34"

WATER PROOFING ROUGH OPENING

ADD SILL RECEPTOR AND END DAM

COMPLETING WINDOW SYSTEM

BUTYL FLASHINGTAPE AT TOP OFBLDG PAPER

BUTYL FLASHINGTAPE APPLIEDPRIOR TO BLDGPAPER W/ 3" MIN.FLAP

2ND SURFACEWATERPROOFINGAPPLIED OVERSTUDS &PLYWD

WINDOW BOT.TRACK (SILLRECEPTOR)

PLASTIC3/8"SPACERSHIM

WOODFRAMING

END DAM @WINDOW BOT.TRACK

795 DOW CORNINGSILICONE (OR EQ.)OVER LAG BOLT/WASHER THRUBOT. TRACK (TYP) &AT END DAM

NOTE: WOOD SILLS& JAMBS SHALL BEPRESSURETREATED

EXTEND FACE OF ALUMANGLE FOR CAULK &BACKER ROD

5"

3"

WINDOW FLASHING -ALUMINUMFINISH TO MATCHSTOREFRONT

MAINTAIN POSITIVEDRAINAGE AWAYFROM WALL ATALL FLASHING

AFTER FRAMING 2ND SURFACE WATER PROOFING PER EIFS MANUFACTURER.ADD FLASHING TAPE AROUND THE ROUGH OPENING FOR THE WINDOW ANDDOOR OPENING

THIS DIAGRAM SHOWS THE APPLICATION OF SILL RECEPTOR.USE 100% PURE ISOPROPYL ALCOHOL TO CLEAN METALSURFACE PRIOR TO APPLYING SILICONE.

SET STOREFRONT WINDOW, APPLY EIFS SYSTEM AND THEN ADD WINDOWFLASHING OVER TOP OF EIFS AT WINDOW SILL

2ND SURFACEWATERPROOFINGAPPLIED OVERSTUDS &PLYWD

PLYWOODWALLSHEATHING

2ND SURFACEWATERPROOFINGAPPLIED OVERSTUDS &PLYWD

WOODFRAMING

PLYWOODWALLSHEATHING

WEEP HOLES @ 24" O.C.

3 /8" SPACECONTINUOUS AROUNDENTIRE WINDOW

INSERT FLASHING BELOW SILLRECEPTOR THEN CAULK

NOTE: DO NOT CAULK /OBSTRUCT WEEP HOLESDRILLED IN SILL RECEPTOR

EXTERIOR FINISH

GLAZING SYSTEM

STOREFRONTWINDOWBODY

BACKER ROD &CAULK ON TOP OFSILL FLASHING CONSTRUCTION

DETAILS

DOOR / WINDOW

A8.0

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

ASTOREFRONTJAMB DETAIL 3" = 1'-0"

BSTOREFRONTJAMB DETAIL 3" = 1'-0"

CTYPICALWINDOW SILL 3" = 1'-0"

DTYPICALWINDOW HEAD 3" = 1'-0"

EJAMB @SERVICE DOOR 3" = 1'-0"

FTHRESHOLD @SERVICE DOOR 3" = 1'-0"

GHEAD @SERVICE DOOR 3" = 1'-0"

HSILL @ FULLHEIGHT OPENINGS 3" = 1'-0"

JNOT USED NTS

KTYPICAL WINDOW WALLWATER PROOFING 3" = 1'-0"

Page 18: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

38.2"

4.25

"

38.2"

8.25

"

18.7

5"

19.00"19.00"

VALANCE WALL REQUIREMENTS26.2" H x 156.8" L (MINIMUM)

IF YOUR VALANCE WALL DOES NOT MEETTHESE REQUIREMENTS PLEASE NOTIFYSTRATACACHE IMMEDIATELY

NOTES:1. EC/GC TO INSTALL A TOTAL OS (4) IG5262 DUPLEX OUTLETS IN (2) QUAD BOXES ON FRONT OF VALANCE WALL AS SHOWN. OUTLETS TO BE ORANGE AND STRAIGHT BLADE.

2. EC/GC TO EVALUATE VALANCE WALL STRUCTURE TO ENSURE ADEQUATE SUPPORT OF DIGITAL MENU BOARDS EQUIPMENT EC/GC TO INSTALL ADDITIONAL BACKINGMATERIALS (AS REFERENCED ON DRAWINGS) AS NEEDED TO ENSURE ADEQUATE SUPPORT OF DIGITAL MENU BOARDS

.3. EC/GC TO INSTALL (1) DATA JUNCTION (JB) IN VALANCE WALL AS SHOWN. CONDUIT TERMINATED ABOVE CEILING TO HAVE BUSHING.

4. EC/GC TO FUN (3) CAT6 LINES FROM NETWORK SWITCH TO DATA JUNCTION BOX. CAT6 LINES SHOULD HAVE BOTH PROPERLY TERMINATED WITH RJ-45 CONNECTORS.EXCESS CAT6 CABLE TO BE COILED INTO SERVICE LOOPS AT EACH END AND LEFT ACCESSIBLE FOR DMB INSTALL TEA. CAT6 TO BE RUN IN ACCORDANCE WITH ALL LOCALMUNICIPALITY CODE REQUIREMENTS.

5. EC/GC SHALL ACQUIRE AND SECURE NY/ALL REQUIRED PERMITTING FOR THE WORK MENTIONED ABOVE PER MUNICIPALITY CODE REQUIREMENTS.

6. DRAWING PROVIDED IS FOR INSTALLATION OF DMB EQUIPMENT ONLY. NOT TO BE USED FOR ARCHITECTURAL PURPOSES. IF PLACEMENT OF REQUIRED ELEMENTSCANNOT BE MET AND WILL EXCEED A 3IN DEVIATION, STRATACACHE MUST BE NOTIFIES IMMEDIATELY.

JB = JUNCTION BOXGC = GENERAL CONTRACTOREC = ELECTRICAL CONTRACTOR

ELECTRICAL SCHEDULEQTY DESCRIPTION VOLT/PH BRK SIZE COND/WIRE PNL/CCT RECP TYPE HGT AFF REQUIREMENT & REMARKS

MENUE BOARD - DIGITAL & MEDIA PLAYER 120/1ISOLATED

20A SEE LAYOUT AND NOTESSEEPLAN

(4)IG5262

4

80.0

0"

0'-0" A.F.F.

NOTE: ALLOWABLE ALTERNATE FRAMING: 3-58" MTL. STUDS

W/FLEX TRACK FOR BULKHEAD FRAMING.

FRANCHISE OPTION ONLY -ROTATING MENU BOARDS

9'-6" A.F.F.

7'-0" A.F.F.

1/2" GYPSUM CEILING

8'-4" A.F.F.

10'-8" A.F.F.

1 1/

2"

WALL FINISH OVER 1/2" PLYWOOD

FRP OVER 1/2" PLYWOOD TOBOTT. OF CEILING

1/2" GYP. BD. PAINTED

TAC

106

2x6 JOISTS @ 16" O.C.2x4 BRACE @ 16" O.C. TO STRUC. ABOVE

2x8 STUDS @16" O.C.

2x6 @ 16" O.C.W/ SIMPSON'A34' EA END

SIMPSON ' @ 'LTP4'@ 16" O.C.

2x6 @ 16" O.C. W/ SIMPSON 'A34' EA END

2x6 @ 16" O.C.W/ SIMPSON'A34' EA END

(3) 16d NAILS EA END

2x6 STUDS @ 16"O.C. SUSPENDEDFROM STRUCTURE

TRUSS AT D/TSHEAR WALL

4"2X4 STUDS @

16" O.C.

1/2" GYP. BOARDTO DECK

DEEPER GROUTBACKING @ FOH TILEBASE

FOH TILE BASE

DEEPER GROUT BED@ FOH FLOOR TILEFLOAT TO BOH TILELEVEL

BOH TILE BASE

FPR PANEL & TRIM

FOH WALL FINISH

THINNER GROUT BASE BEHIND THE BOH TILE BASEBECAUSE BOH TILE BASE IS THICKER THAN THE FOHBASE. NOTE: THIS WILL TYP. OCCUR ON SHORTWALLS ONLY.

TRIM CORNER OFFOH BASE TILE

HEADER - SEESTRUCTURAL

1/2" GYP. BOARD

2x FRAMING

EL. 7'-2" R.O.

CASED OPENINGEL. 8'-0 5/8" R.O. AT SIM

YAW

312

5-1/

2" IF

2x4

7-1/

2" IF

2x6

HM FRAME

WD. DOOR

2"5/8"

SEALANT

DOUBLE STUDS AT JAMBAND HEAD WITH ANCHORSTRAP.

SUBSTRATE AS NOTED ONSHEET A1.0

BUNDLED SYRUP LINESAND FILTERED WATER LINES

BOTTOM CHORDOF ROOF TRUSS

YAC

003

OPTIONAL INSTALLATION: 1"WIDE GALV. STRAPS @ EA.TRUSS (MAX. 6'-0" O.C.)

NOTE:SEE SCOPE OF WORK FORSCOPE DEFINITIONS

PROTECT SYRUP LINESFROM TRUSS PLATES

FASTEN 2X BLOCKING TO FACE OFADJACENT WALL OR TRUSS

1'-6

"6"

SECTION VIEW

YAC

004

7" DIA. OPENING IN CEILING TILE

PLUMBER'S TAPE STRAP

SYRUP LINE BUNDLE THRU CLG.

6" PVC

NOTE: SEE DETAIL 11/P6.0 DRINK SYSTEM SCHEMATIC & DETAIL 12/P6.0 FOR DRINK LINES

S.S. DRINK LINE CHASE.4" D X 10" W X 30" H W/ 1"FLANGES. FASTEN W/S.S. SCREWS CLEARCAULK

LINE OF CLG.PERIMETER

OUTLINE OF DRINK &ICE MACHINE

DRINK LINE THROUGHOPENINGS IN TABLE

DRINK LINES FROM WATER FILTER,SYRUP RACK & Co2 CANISTER INBACK OF KITCHEN ABOVE CEILING

CENTERBEHIND ANDABOVE DRINK& ICE MACHINE

OPENING IN WALL BELOW. SEEDETAIL 11/A6.4

VENT TO ROOF FOR F.S.

VERTICAL SYRUP CHASE FROM ABV.CLG. TO BELOW TOP OF DRINKMACHINE. SEE DETAIL 19/A6.4.

J-BOXES ON ONE SIDE OF STUDALIGNED VERTICALLY

2 x

6

VERTICAL SYRUP CHASE FROM ABV.CLG. TO BELOW TOP OF DRINKMACHINE. SEE DETAIL 19/A6.4.

OUTLINE OF DRINK TABLE.

NOTE: COORDINATEPLACEMENT OF INWALL ITEMSWITH PLUMBING ANDELECTRICAL TRADES. SEESHEET P4.0, E3.0 AND E5.0

J-BOXES ON EITHER SIDE OFSTUD ALIGNED VERTICALLY

J-BOXES ON ONE SIDE OF STUDALIGNED VERTICALLY

J-BOXES ON EITHER SIDE OFSTUD ALIGNED VERTICALLY

1'-0

"1'

-4"

10"

1'-0

"1'

-7"

1'-0

"

HOLD DOWN - SEESTRUCTURAL DRAWINGS

HOLD DOWN - SEESTRUCTURAL DRAWINGS

3"

CHASE FOR FRONT COUNTERWIRING

SE

E S

HE

ET

A1.

0

E

CONSTRUCTION

DETAILS

INTERIOR

A8.1

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

AWALL MOUNTED DMB DETAIL NTS

BMENU BOARD/SOFFIT SECTION 1" = 1'-0"CTILE BASETRANSITION NTS

DCASED OPENING DETAIL 1" = 1'-0"GJAMB @

H.M DOOR 1" = 1'-0"

JSYRUP BUNDLECLG. PENETRATION NTS

KSYRUP LINEIN CEILING NTS

HNOT USED NTS EINTERIOR CHASEWAL NTS

FSYRUP CHASEON WALL NTS

AutoCAD SHX Text
QUAD OUTLET BEHIND MENU BOARD TYP.
AutoCAD SHX Text
MEDIA PLAYER
AutoCAD SHX Text
QUAD OUTLET
AutoCAD SHX Text
MEDIA PLAYER BEHIND MENU BOARDS TYP.
AutoCAD SHX Text
JUNCTION BOX (JB) WITH CONDUIT THROUGH TO CEILING
AutoCAD SHX Text
12" PLYWOOD BACKING (150" X 18") TO BE INSTALLED BEHIND THE DRYWALL/FINISHED WALL SURFACE
AutoCAD SHX Text
2-4" MINIMUM CLEARANCE FROM BOTTOM OF VALANCE WALL TO BOTTOM OF DISPLAY
AutoCAD SHX Text
BOTTOM OF VALANCE WALL
AutoCAD SHX Text
DMB'S TO BE CENTERED ON WALL
AutoCAD SHX Text
DMB MOUNTING BRACKET TYP.
Page 19: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

YAW

022

J MOLD SET IN SILICON SEALANT -FILL J-MOLD W/ SILICON PRIOR TOINSTALLING FRP, WIPE OFF EXCESS

SANITARY COVE BASE TILE -SET FLUSH W/ FLOOR TILE

WALL SUBSTRATE PER SHT. A1.0

WALL FINISH PER INTERIORELEVATIONS

YAW

022

FRP

SUBSTRATE PER PLAN

CEILING TILE & GRID

CONTINUOUS SOLIDBLOCKING BETWEENSTUDS AT CEILING LINE

MONITOR. SEE SHEETA2.0.

MONITOR BASEATTACHMENT. PROVIDEWD. BLKG.

DATA OUTLET. SEESHEET E5.0

ELECTRICAL OUTLET. SEESHEET E3.0

WALL BEHIND

4"4"

NOTE: VIEW IS LOOKING UP ATWALL BEHIND SERVICE COUNTER &BOTTOM OF MENU BOARD SOFFIT.

MINMIN

COVE BASE TILE - SETFLUSH W/ FLOOR TILE

WALL SUBSTRATE PER SHT. A1.0

WALL SUBSTRATE PER SHT. A1.0

SILICON SEALANT

J MOLD SET IN SILICON SEALANT -FILL J-MOLD W/ SILICON PRIOR TOINSTALLING FRP, WIPE OFF EXCESS

WALL SUBSTRATE PER SHT. A1.0

WALL FINISH PER INTERIORELEVATIONS

3/4" RADIUS

6" ACRYLIC RESIN SEAMLESSCOVE BASE AND ACRYLICRESIN FLOORING

OPTIONAL

WALL SUBSTRATE PER SHT. A1.0

COVE BASE TILE - SET FLUSH W/FLOOR TILE

WALL FINISH PER INTERIORELEVATIONS

CHAIR RAIL.

34"

11 2"

R 14 "

NOTE: SEE INTERIORELEVATIONS FORFINISHES

YAF0

59

2'-9 1/2"ELEV.

EXISTINGSUBSTRATE

SEALANT

MARMOLEUMWAINSCOTING

D-755

D-75314" LUANPLYWOOD.

24" M

IN.

EQ

.

NOTE: CAULK ALL SEAMS AT WALLSURFACE.

1"

2" FLANGEBENT 90DEG.

EQ

.E

Q. 16 GA. BRUSHED

STAINLESS STEEL. 1/2"HEM ON TOP, FRONTAND BOTTOM EDGES.

BOTTOM EDGE OFSPLASH GUARD SHALLBE EVEN W/ THE EDGEOF THE HIGHEST ADJ.SINK.

EXTEND FRONT OF PANELTO FRONT EDGE OF ADJ.SINK. APPROX. 24" (SEEPLAN)

1/2" RAD. EASEDCORNER (TYP.)

1"

(4) #12 S.S. WOODSCREWS 3/4" LG. W/ S.S.WASHERS.

SEE PLAN

FASTEN S.S.WITH CONSTR.ADHESIVE

EXTEND S.S.WALL GUARDBEYONDSURFACE OFWALL THE DEPTHOF THE TILE ANDRETURN TO THEWALL.

20 GA S.S. WALLGUARD FROM TOPOF TILE BASE TOCEILING

FRP WALLFINISH

S.S. WALLGUARD FLUSH

WITHSURFACE OF

FRP

TILE WALLBASE

GROUT LINE

S.S. WALLGUARD FLUSHw/ TILE FLOOR

FLOOR TILE

2"2"

NOTE: THIS DETAIL SHOW A 90 DEGREE CORNER. ADAPT THIS DETAIL AND APPLYWHERE WALLS EXTEND INTO SPACE.

FINISH DETAILS

A8.2

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

AKITCHEN FINISHAT BASE 3" = 1'-0"

BKITCHEN FINISHAT CEILING 3" = 1'-0"

CWALL MOUNTMONITOR 3" = 1'-0"

DBASE @ DININGINTERIOR WALL 3" = 1'-0"

ERESIN BASEAT INTERIOR WALL 3" = 1'-0"

FBASE INRESTROOM 3" = 1'-0"

GCHAIR RAILDETAIL 3" = 1'-0"

HSPLASH GUARDDETAIL 3" = 1'-0"

JS.S CORNER &END WALL GUARD 3" = 1'-0"

KNOT USED 3" = 1'-0"

LNOT USED 3" = 1'-0"

MNOT USED 3" = 1'-0"

Page 20: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

FINISH

SCHEDULE

A8.3

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

BROOM FINISH NOTES NTS

AROOM FINISH SCHEDULE NTS

CFINISH LEGEND NTS

KEY NAME MANUFACTURER STYLE COLOR SIZE GROUT COMMENTS

CEILING

CL-1 CERTAINTEED TILE ACT VINYL ROCK #1140 WASHABLE NON

PERFORATED

2X4X1/2" N/A WHITE SUSPENDED GRID W/ALUMINUM, BOH

FLAME SPREAD RATING 0-25, CLASS A

FLAME SPREAD RATING 0-25, CLASS A

CL-2 CEILUME STRATFORD WHITE 2X2 N/A CEILING GRID TO BE PAINTED SW6080 UTTERLY

BEIGE

CL-3 CERTAINTEED TILE ACT VINYL ROCK #1140 WASHABLE NON

PERFORATED

2X2X1/2" N/A WHITE SUSPENDED GRID W/ALUMINUM,

KITCHEN FLAME SPREAD RATING 0-25, CLASS A

FLAME SPREAD RATING 0-25, CLASS A

CL-4 ARMSTRONG AXIOM CLASSIC TRIM MATCH CL-2 10" H

PROFILE

N/A

CL-16 CEILING GYPSUM BOARD P-2 N/A N/A FRAME WITH 2X4 MTL STUDS

CHAIR RAIL / TRIM

CR-1 MINWAX STAINED MAPLE CHAIR RAIL MINWAX: CLASSIC GREY STAIN 1"X2" N/A APPLY 2 COATS OF STAIN PER

MANUFACTURER'S SPECIFICATIONS

CR-2 MINWAX STAINED MAPLE CHAIR RAIL MINWAX: CLASSIC GREY STAIN 1"X2" N/A APPLY 2 COATS OF STAIN PER

MANUFACTURER'S SPECIFICATION. 1X1 TRIM TO

BE ADDED AFTER MURAL/ARTWORK IS

INSTALLED. REFER TO ARTWORK CATALOG

FROM TACOBELLPLANS.COM FOR ADDITIONAL

ARTWORK INFORMATION. GC TO FEILD VERIFY

ACTUAL SIZE OF ARTWORK/MURAL WALL

FLOOR BASE

B-1 EUROWEST PURITAN GREY #507 6"X6" MAPEI # 106 WALNUT, 1/8"

JOINT WIDTH

B.O.H, KITCHEN

B-1a CREATIVE

MATERIALS

QUARRY PURITAN GREY #507 3X6 MAPEI # 106 WALNUT, 1/8"

JOINT WIDTH

STACK BOND INSTALLATION

B-2 EUROWEST URBAN WEAVE X606292X8 GREY 3"X24" MAPEI # 2 PEWTER, 1/8"

JOINT WIDTH

DINING ROOM, ALCOVE,RESTROOM

B-2a CREATIVE

MATERIALS

PORTLAND HOOD, BULLNOSE 3X24 MAPEI # 2 PEWTER, 1/8"

JOINT WIDTH

FLOORING

T-1 EUROWEST PURITAN GREY #507 6"X6" MAPEI # 106 WALNUT, 1/8"

JOINT WIDTH

B.O.H, KITCHEN

T-5 EUROWEST URBAN WEAVE X606293X8 IVORY 24"X24" MAPEI # 2 PEWTER, 1/8"

JOINT WIDTH

DINING ROOM, ALCOVE, RESTROOMS

T-5a CREATIVE

MATERIALS

PORTLAND HOOD 2.0 DECO 24X24 MAPEI # 2 PEWTER, 1/8"

JOINT WIDTH

ALTERNATE FOH/RESTROOM FLOOR TILE

LAMINATE

FRP-1 MARLITE S-5373 SMOOTH FINISH 4'X 9'X.90 FOR CALIFORINA STORES: FRP S100 WHITE

SMOOTH FINISH S/2/S 4' X 9'X .90

L-2 WILSONART YO486-22 TIMEWORN COPPER POS / PICK UP COUNTER FACE

L-3 WILSONART 4994-60 FIRED STEEL, MATTE FINISH OPEN KITCHEN WALL / SHROUD

L-4 NEVAMAR WK0027T BAILEY DOOR LAMINATE, DOOR EDGES TO BE FINISHED

SIMILAR TO FACES

L-4a WILSONART 17005K-57 MORRIS OAK

L-10 NEVAMAR S7027T SMOKEY WHITE LAMINATE FOR OFFICE SHELVING

METAL TRANSITION

MT-1 SCHLUTER DILEX AHK AT: SATIN NICKEL ANODIZED ALUMINUM FOR STORES IN CALIFORNIA ONLY USE: AE:

SATIN ANODIZED ALUMINUM

MT-2 SCHLUTER JOLLY SATIN ANODIZED ALUMINUM VERTICAL TRIM AT WALL TILE TO GYPSUM

BOARD TRANSITION DINING/POS AREA

MT-3 SCHLUTER DILEX AHK EB: BRUSHED STAINLESS STEEL BRUSHED STAINLESS STEEL COVE BASE TRIM

WHERE WALL TILE MEETS DINING FLOOR

MT-4 SCHLUTER SATIN ANODIZED ALUMINUM METAL SILVER TRIM AT VERTICAL WAINSCOT

SEAMS

PAINT

P-2 SHERWIN

WILLIAMS

SW7043 WORLDLY GRAY, SEMI-GLOSS N/A N/A PRIMER: #23 (WHITE) FRESH START 100%

ACRYLIC

P-3 SHERWIN

WILLIAMS

SW7026 GRIFFIN, SEMI-GLOSS N/A N/A PRIMER: #23 (WHITE) FRESH START 100%

ACRYLIC

P-8 SHERWIN

WILLIAMS

SW7026 GRIFFIN, FLAT FINISH N/A N/A PRIMER: #23 (WHITE) FRESH START 100%

ACRYLIC

TILE

T-2 EUROWEST MAY AZURE 4"X12" SILVER # 27 MEPEI, 1/8"

JOINT WIDTH

RESTROOM ACCENT WALL, STACK BOND

INSTALLATION

T-3 EUROWEST 4"X12" RESTROOM WALLS, STACK BOND INSTALLATION

T-4 EUROWEST MAIOLICA 4"X12" KITCHEN ACCENT WALL, RUNNING BOND

INSTALLATION

WALL COVERING

WC-1 WOLF GORDON 'RAMPART' HIGH IMPACT WALL

COVERING

FOUNDATION/ PIGMENT (GDH ICI72606) 1 ROLL: 80LF

FINISH KEY

NAME

FLOOR

FINISH

BASE

FINISH WALL FINISH

ACCENT

WALL

CEILING

FINISH

CEILING

HEIGHT COMMENTS

DINING T-5 B-2 P-2, P-3, P-8, CR-1 N/A CL-2 12'-0" MIN

WOMENS RESTROOM T-5 MT-1 T-3 T-2 CL-16 8'-6"

FOOD ASSEMBLY T-1 B-1 FRP-1, P-2 T-4 CL-3 10'-0" MIN

BOH T-1 B-1 FRP-1 N/A CL-1 9'-0" MIN

MENS RESTROOM T-5 MT-1 T-3 T-2 CL-16 8'-6"

ALCOVE T-5 B-2 P-2, P-3, CR-1 N/A CL-16 10'-0"

WALK IN COOLER T-1 B-1 N/A N/A N/A N/A

WALK IN FREEZER N/A N/A N/A N/A N/A N/A

OFFICE T-1 B-1 FRP-1 N/A CL-1 9'-0"

1. INSTALL FRP ON KITCHEN SIDE OF SERVING COUNTER WALL.

2. GALV. STEEL WALL AND CEILING FINISHES BY WIX/WIF BOX MFR.

3. REFER TO INTERIOR ELEVATIONS FOR LOCATIONS OF TILE AND FRP.

4. FOR FINISH LOCATIONS REFER TO:

a. SHEET A4.0 EXTERIOR ELEVATIONS

b. SHEET A7.0 FLOOR FINISH PLAN

c. SHEET A7.1 – REFLECTED CEILING PLAN

d. SHEET A8.0 TO A8. 2 – INTERIOR ELEVATIONS

5. APPROVED PAINT MANUFACTURERS: PORTER, BENJAMIN MOORE, SHERWIN WILLIAMS, ICI, & PITTSBURG PAINTS

MATCH SPECIFIED SCHEDULE COLORS EXACTLY

6. ALL PAINTED GYPSUM BOARD SHALL HAVE A LIGHT ORANGE PEEL TEXTURE

7. ALL MORTAR SHALL BE MIXED WITH WHITE SAND TO INSURE A COLOR CONSISTENT THE ORIGINAL INTENT

MAY AZURE 512006

SILVER # 27 MEPEI, 1/8"

JOINT WIDTH

AQUA MARINE

MAY DEC AMBER LIGHT. ALMOND # 27 MEPEI,

1/8"

JOINT WIDTH

AMBER 512020

P-100 WHITE PEBBLE

SOFTGRAIN/ ANTIQUE FINISH

Page 21: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

2

3

4'-614" 5"

8'-3

1 4"

4'-212"8'-63

4"

3'-9

3 4"4'-7

"

4'-1014"

N-141N-146

B-241 B-251

B-253

B-265

B-253

B-275B-305B-310

B-300

B-253B-275

B-292

B-253

B-275B-305

B-310

N-141B-265

B-300MEN'S RR

WOMEN'SRR

F

G

H

JA8.01

B

C

D

EA8.01

B-251

XXX

XXX

1'-0" 5" 4"

1'-6"

XXX

XXX

N-146

T-02

B-02

8'-3" V.I.F.B.O. CEILING

0'-0"FLOOR FINISH LVL.

B-300XXX XXX

B-253B-275

B-02

8'-3" V.I.F.B.O. CEILING

T-03

0'-0"FLOOR FINISH LVL.

B-292

B-251B-265N-141N-146

B-02

P-3

8'-3" V.I.F.B.O. CEILING

T-03

0'-0"FLOOR FINISH LVL.

B-02

8'-3" V.I.F.B.O. CEILING

T-03

0'-0"FLOOR FINISH LVL.

B-300XXX

B-253

B-275B-305

B-310

8'-3" V.I.F.B.O. CEILING

B-02

P-3

0'-0"FLOOR FINISH LVL.

T-03

B-02

8'-3" V.I.F.B.O. CEILING

T-03

0'-0"FLOOR FINISH LVL.

B-300

XXX

B-253B-275

B-305B-310

B-02

8'-3" V.I.F.B.O. CEILING

T-03

0'-0"FLOOR FINISH LVL.

B-251B-265N-141N-146

B-292

B-02

8'-3" V.I.F.B.O. CEILING

T-02

0'-0"FLOOR FINISH LVL.

B-251B-265N-141N-146

B-300XXX

B-253B-275

B-292

PROVIDE PROPER 2x BLOCKING AT WALL RECESSED MOUNTED ACCESSORIES.

GRAB BARS, FASTENERS AND MOUNTING DEVICES SHALL BE INSTALLED PER ADA REQUIREMENTS.

REFER TO FLOOR PLAN NOTES FOR BLOCKING AND SUBSTRATE NOTES.

REFER TO SHEET ADA1.0 FOR MOUNTING HEIGHTS AND CLEARANCES OF ACCESSORIES AND FIXTURES.

ALL DIMENSIONS OF THIS DRAWING ARE TO FINISH SURFACE

PAINT DOOR FRAMES P-X BOTH SIDES.

1

2

3

4

5

6

NOTE: SITE SPECIFIC ARCHITECT SHALL VERIFY THAT RESTROOM CONFIGURATION, PLUMBING FIXTURES, AND TOILETACCESSORIES ARE COMPLIANT WITH FEDERAL, STATE, AND LOCAL ACCESSIBILITY CODES.

ARESTROOM - PLAN 1/2" = 1'-0"

HINTERIOR ELEVATION 3/8" = 1'-0"

EINTERIOR ELEVATION 3/8" = 1'-0"GINTERIOR ELEVATION 3/8" = 1'-0"

BINTERIOR ELEVATION 3/8" = 1'-0"

JINTERIOR ELEVATION 3/8" = 1'-0" CINTERIOR ELEVATION 3/8" = 1'-0"

FINTERIOR ELEVATION 3/8" = 1'-0" DINTERIOR ELEVATION 3/8" = 1'-0"

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

KGENERAL NOTES

ENLARGED

RESTROOM PLAN

AND ELEVATIONS

A9.0

Page 22: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

46" M

AX.

>10-24" MAX

24" MAX.30"

34" M

AX

46" M

AX.

10" MAX.30"

15" M

IN.

48" M

AX.

48" M

AX.

10" MAX

48" M

AX.

15" M

IN

48" M

AX.

20" MAX

44" M

AX.

>20-25" MAX

NOTE: SEE DOOR SCHEDULE. AND DOOR SCHEDULE NOTES

MOUNT COAT HOOK ONINSIDE OF TOILET STALLDOOR

48" A

.F.F

MA

X.

BOBRICK OR CHRISTYCOMMERCIALHARDWARE & SUPPLYWAREHOUSE#039-6529 OR SIMILARADA COMPLIANT HOOK.

CHRISTYHARDWARE.COM877-544-5400

B

REQ'D INCA ONLY

REQ'D INCA ONLY

NOTE: SEE DOOR SCHEDULE. AND DOOR SCHEDULE NOTES

REINFORCED S.S.LATCH WITH THROUGHBOLTED KEEPER. ADACOMPLIANT

48" A

.F.F

MA

X.

34" A

.F.F

MIN

.

S.S. PULL (BOTH SIDES)ON ALL ACCESSIBLETOILET STALLS. MOUNTPULLS BELOW LATCHAND KEEPER.

NOTE: DOOR HOOKSSHALL BE PLACED INACCESSIBLE STALLSBETWEEN 40" MIN TO48" MAX ABOVE FINISHFLOOR

ACCESSIBLE ROUTE

PROTRUDING OBJECT

FREESTANDING OBJECTMOUNTED ON POSTS ORPYLON MAY OVERHANG 12"MAX FROM 27" TO 80"ABOVE FINISH FLOOR

OBJECT PROJECTION FROMWALL BETWEEN 27" TO 80"ABOVE FINISH FLOOR SHALLPROTRUDE NO MORE THAN4"

OBJECT PROJECTIONFROM WALL LESS THAN27" ABOVE FINISH FLOORMAY PROTRUDE ANYAMOUNT

FLOOR SHALL BESLIP-RESISTANT SURFACEAND LEVEL WITH MAX 1/4"CHANGE IN LEVEL

SIGN POST OBSTRUCTION

ACCESSIBLE ROUTE WALK

21

1/4"

- 1/

2"1/

4" M

AX

VERIFY

WITH

LOCAL

STANDARDS

CLEAR30"19"

CLE

AR

30"

CLEAR30"19" CLEAR

CLE

AR

30"

48"

YAM

016

INSULATE HOT WATER & DRAINPIPES

6" MAX. DEPTH x 30" MIN. WIDTH TOECLEARANCE

HIG

HE

ST

OP

ER

AB

LEP

AR

T (C

ALI

FOR

NIA

)

8" MIN. DEPTH x 30" MIN.WIDTH KNEE SPACE

LAV.

MIRROR MTD @ 40" A.F.F.MAX TO BOTTOM OFREFLECTING SURFACE

14" MIN. / 17" MAX.PROJECTION FROMWALL URINAL

CONTROLS MOUNTED ON

WIDE SIDE OF TOILET AREA

48" S.S. GRAB BAR

36" S.S. GRAB BAR

33" MIN. TO 36" MAX.TO TOP OFGRIPPING SURFACE

PAPER TOWEL DISPENSERDRYER

T.S. COVER DISPENSER SHALLBE MOUNTED 1 1/2" (MIN.)BELOW GRAB RAIL

SWITCHES

FIRE ALARM

THERMOSTAT

2'-0"

2"M

AX

17"-1

9"

7"-9"

34" M

AX.

29" M

IN.

27" M

IN.

40" M

AX.

TO

17" M

AX.

44" M

AX.

40" M

AX:

CA

LIF

1'-0

"M

IN.

17"-19"

6"8"

PULL STATION

1 1 2"

MIN

.

7" -9"17

" to

19"

39" to 41"

6" TO 12" MAX

39" t

o 41

"

18" VERTICAL S.S. GRAB BAR(IF RQ'D)

19" TO 48" A.F.F. FOR OPERABLEOPENING W/O OBSTRUCTIONFROM GRAB BAR

48" M

AX:

AD

ATO

OP

ER

AB

LEP

OIN

T

17" M

AX

40" M

AX:

CA

LIF

48" M

AX:

AD

A

40" M

AX:

CA

LIF

48" M

AX:

AD

A

NOTES:

1. TOP OF GRIPPING SURFACE 33" TO 36" MAX TO THE TOP OF

THE BAR. SEE NOTES BELOW2. 12" MINIMUM CLEAR

ABOVE GRAB BAR

9"M

IN.

54" MAX.

48" MIN.

30" M

IN.15

" MIN

.

CLEARFLOORSPACE

18" M

IN. F

OR

CA

LIFO

RN

IA

17" MIN.

GRAB BAR SHALL BE 1-1/4" TO 2" MAX.,OUTSIDE DIA.- TYPICAL

2- 1/4"x3' EXPANSION ANCHORS ATMASONRY OR CONC. WALL 2- #10x2"SCREWS AT WOOD OR STEEL STUDWALL-TYP.

2"x6" BLOCKING AT WOOD STUD WALLS(OMIT BLOCKING AT MASONRY ORCONC. WALL) - TYPICAL

1'-0

" MIN

.C

LEA

R1

1/2"

MIN

.

112"

MIN.CLR.

18" M

IN.

48" MIN.

30" M

IN.

15" M

IN.

CLEARFLOORSPACE

13 1/2"MAX

30" MIN

27"M

IN.

VERIFY

WITH

LOCAL

STANDARDS

ACCESSIBILITY

REQUIREMENTS

ADA1.0

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

AGENERALNOTES NTSHCHANGES IN

LEVEL NTSLPARTITION DOORLATCH AT PULL NTSPTILE BASE

TRANSITION NTS EDINING ROOM SEAT--ING CLEARANCES NTS

BACCESSIBLELAVATORY 1/2" = 1'-0"JPROTRUDING

HAZARDS 1/2" = 1'-0"MACCESSIBLE RESTROOM DOORS NTS FGRAB BAR NTS

CSTANDARD TOILETSTALL 1/2" = 1'-0"KINT. ACCESS

ROOT CLEARANCES 1/2" = 1'-0"NREACHRANGES NTSRSEATING

& TABLES NTS GACCESSIBLEURINAL NTS

DMOUNTING HTS. AND CLEARANCES FOR ACCESSIBILITY FOR DISABLES NTS

1. INDICATED DIMENSIONS, HEIGHTS, DEPTHS, AREAS AND OTHER GRAPHIC INFORMATIONARE PROVIDED AS MINIMUMS THAT MUST BE MAINTAINED. THESE MINIMUMS ARE BASEDUPON YUM STANDARDS AND MAY EXCEED ADA REQUIREMENTS. THE DETAILS SHOWNARE CONCEPTUAL ONLY AND INTENDED TO SHOW ABSOLUTE MINIMUMS AND SHALL BECOORDINATED WITH THE OTHER CONSTRUCTION DOCUMENTS ASSOCIATED WITH THISPROJECT.

2. 60" TURNING SPACE - PERMITTED OVERLAP LIMITED TO 1 ARM OF T-SHAPED SPACE -CAN OVERLAP FIXTURE & DOOR CLEARANCE - DOOR CAN SWING INTO TURNING SPACEA MAXIMUM OF 12".

3. RESTROOM, IN GENERAL, DOOR SWING MUST BE OUTSIDE OF THE FIXTURE CLEAR FLOORSPACE HOWEVER A DOOR CAN SWING INTO FIXTURE CLEAR FLOOR SPACE IFWHEELCHAIR SPACE 30"X48" IS PROVIDED BEYOND THE DOOR SWING.

4. TOILET ROOM MUST ALLOW FOR SIDE TRANSFER - 42" BETWEEN FIXTURES.

AutoCAD SHX Text
CONDIMENTS
AutoCAD SHX Text
EXAMPLE: DRINK MACHINE, ETC.
AutoCAD SHX Text
36" MIN. CLR.
AutoCAD SHX Text
27"
AutoCAD SHX Text
12"
AutoCAD SHX Text
4"
AutoCAD SHX Text
80" MIN.
AutoCAD SHX Text
27" MIN
AutoCAD SHX Text
12" MAX
AutoCAD SHX Text
ACCESSIBLE ROUTE
AutoCAD SHX Text
ACCESSIBLE ROUTE
AutoCAD SHX Text
NOTE: 1. INTERNATIONAL SYMBOL OF ACCESSIBILITY REQUIRED ON TOP EDGE OR INTERNATIONAL SYMBOL OF ACCESSIBILITY REQUIRED ON TOP EDGE OR FRONT OF ALL ACCESSIBLE TABLES.
AutoCAD SHX Text
12" MAX. (305)
AutoCAD SHX Text
4'-8" MIN. (1420) W. WALL MOUNTED W.C.
AutoCAD SHX Text
4'-11" MIN. (150) W. FLR. MOUNTED W.C.
AutoCAD SHX Text
OTHER APPROACHES 4'-0" MIN. HINGE APPROACH 3'-6"MIN. LATCH APPROACH ONLY,
AutoCAD SHX Text
4'-6" MIN. (1320)
AutoCAD SHX Text
5'-0" MIN. (1525)
AutoCAD SHX Text
1'-0" MIN. (304)
AutoCAD SHX Text
TOILET PAPER
AutoCAD SHX Text
DOOR LOCATION
AutoCAD SHX Text
ALTENATE
AutoCAD SHX Text
(100)
AutoCAD SHX Text
4" MAX.
AutoCAD SHX Text
(100)
AutoCAD SHX Text
2'-8" MIN. (815)
AutoCAD SHX Text
2'-8" MIN.
AutoCAD SHX Text
(815)
AutoCAD SHX Text
4" MAX.
AutoCAD SHX Text
VERTICAL GRAB
AutoCAD SHX Text
BAR. SEE DTL 1
AutoCAD SHX Text
** IF TOILET STALL IS CONSTRUCTED OF SOLID WALLS WITHOUT 9" OF TOE CLEARANCE UNDER PARTITION, PROVIDE ADDITIONAL 6" WIDTH AND DEPTH
AutoCAD SHX Text
16" MIN. TO 18" MAX
AutoCAD SHX Text
PLATE @ 4'-0"
AutoCAD SHX Text
1/8"x2" BENT PLATE WELDED TO RAIL
AutoCAD SHX Text
AND1/8"x3" DIAMETER MOUNTING
AutoCAD SHX Text
TOTAL SEATS ACCESSIBLE SEATS
AutoCAD SHX Text
28"-34" A.F.F.
AutoCAD SHX Text
NUMBER OF ACCESSIBLE SEATS
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
1 - 20 1 21 - 40 2 41 - 60 3 61 - 80 4 81 - 100 5 101 - 120 6 121 - 140 7
Page 23: ADA1.1 ACCESSIBILITY REQUIREMENTS · 2020-08-05 · reference symbol 2415 san ramon valley blvd #306 san ramon, ca 94583 usa sheet index name room name sheet number elevation number

2.35"

0.9"BASE DIAMETER0.45"TOP DIAMETER

NOMINAL

A A

0.2"

HE

IGH

T

SPACING PLAN

SECTION A-A

TAPER EDGEWHERE EXPOSED

BASE DIAMETER

TOP DIAMETER

VERIFY

WITH

LOCAL

STANDARDS

32" MIN.CLR. OPENING

18"24" REQ. IN

CA. FOREXTERIOR

DOORS 60"

1/2"

MA

X.

MIN. 60 DEGREE SLOPE

BOTTOM RAIL OF DOOR

ALUMINUM THRESHOLD

#10 S.M. IN PLASTICEXPANSION ANCHOR

10" M

IN.

VERIFY

WITH

LOCAL

STANDARDS

VERIFY

WITH

LOCAL

STANDARDS

VERIFY

WITH

LOCAL

STANDARDS

VERIFY

WITH

LOCAL

STANDARDSVERIFY

WITH

LOCAL

STANDARDS

VERIFY

WITH

LOCAL

STANDARDS

34" -

38"

34" -

38"

3" ±

1" H

IGH

12" MIN.

34" -

38"

GU

IDE

RA

ILC

EN

TER

ED

AT

3" ±

1" H

IGH

60" MIN.

DO

OR

WD

TH. P

LUS

42"

12" MIN.

36" MIN.

24" MAX 48" MIN 24" MAX

32" M

IN

36" M

IN

12" MIN.

8' MIN.5' MIN.11' MIN.

VERIFY

WITH

LOCAL

STANDARDS

NOTE:DETAIL IS MEANT AS A GENERAL GUIDELINE. REFER TOLOCAL MUNICIPALITY FOR SIGN TYPE, VERBAGE ANDDIMENSIONS.

NOTE:SIGNS SHALL BE LOCATED SO THAT THEYCANNOT BE OBSCURED BY A VEHICLE PARKED INTHE SPACE.

NOTE: VAN ACCESSIBLESIGN NOT REQUIRED ONUNIVERSAL OR STANDARDSTALLS.

1'-0"

3"2'

-0"

80" M

IN. W

HE

N O

N A

CC

ES

SIB

LE R

OU

TE60

" MIN

. WH

EN

NO

T O

N A

CC

ES

SIB

LE R

OU

TE

12"

18"

GALVANIZED METAL SIGN POST

CONCRETE

FINISH GRADE

HANDICAP SIGN

VERIFY

WITH

LOCAL

STANDARDS

60" MIN.

VERIFY

WITH

LOCAL

STANDARDS

24"

48"

95"

48" M

IN.

95" M

IN.

VERIFY

WITH

LOCAL

STANDARDS

DOOR HANDLE,SEE HARDWARENOTES

DOOR CLOSER IFPROVIDED, SHALLHAVE AT LEAST A5-SECONDCLOSING TIMEPERIOD FROM 90°

OPEN POSITIONTO 12° FROMLATCH

3'-0" DOOR WIDTH

34" T

O 4

4"

PROVIDE ISA DECAL@ ALL PUBLICACCESSIBLEENTRANCES

10"

MIN

.

60"

ACCESSIBILITY

REQUIREMENTS

ADA1.1

THE

SE

DO

CU

ME

NTS

AR

E P

RO

VID

ED

AS

A C

ON

STR

UC

TIO

ND

OC

UM

EN

T TE

MP

LATE

FO

R T

HIS

BU

ILD

ING

TYP

E. T

HE

SE

DR

AW

ING

S M

US

T B

E R

EVI

EW

ED

AN

D A

DA

PTE

D B

Y A

LIC

EN

SE

DA

RC

HIT

EC

T A

ND

/OR

EN

GIN

EE

R T

O M

EE

T A

LL S

TATE

AN

D L

OC

AL

JUR

ISD

ICTI

ON

AL

RE

QU

IRE

ME

NTS

FO

R S

ITE

SP

EC

IFIC

PR

OJE

CTS

.M

OD

IFIC

ATI

ON

S T

HA

T C

HA

NG

E T

HE

IMA

GE

ELE

ME

NTS

OR

KIT

CH

EN

OP

ER

ATI

ON

S M

US

T B

E A

PP

RO

VED

BY

A Y

UM

! BR

AN

DS

RE

GIO

NA

L A

RC

HIT

EC

TUR

AL

PA

RTN

ER

(RA

P) P

RIO

R T

OC

ON

STR

UC

TIO

N.

SEAL

REMOVE THIS DISCLAIMER PRIOR TOPRINTING -

REPLACE WITH CONSULTANT'S LOGO.

CONTRACT DATE:

BUILDING GROUP:

FLOOR PLAN:

SITE NUMBER:

STORE NUMBER:

BRAND DESIGNER:

TACO BELL

SANRAMON

2415 SAN RAMON VALLEY BLVD #306

SAN RAMON, CA 94583 USA

XXXXX

XX-XX

NOV-13-2019 CD SETDATE:

DACCESSIBLE PARKING SIGN NTS ACURB RAMPS NTS

BCURB RAMPS NTSEACCESSIBLEPARKING STALL NTS

CESCAPE PATH OF TRAVEL NTS

FRAMPS NTS

GBOTTOM RAIL(EXTERIOR DOOR) 3" = 1'-0"JTRUNCATED

DOMES NTS

KTYP. ENTRANCE /EXIT DOOR NTS HEXTERIOR DOOR

REQUIREMENTS 3" = 1'-0"

AutoCAD SHX Text
CROSS SLOPE 1:50 OR 2% MAX.
AutoCAD SHX Text
SLIP RESISTANT SURFACE (MEDIUM BROOM FINISH)
AutoCAD SHX Text
CLEAR SPACE FINISH ELEVATION TO MATCH FINISH FLOOR ELEVATION AT DOOR
AutoCAD SHX Text
DOOR AND HARDWARE PER SHEET A1.1
AutoCAD SHX Text
THRESHOLD - SEE DETAILS 10, 17 / A6.1
AutoCAD SHX Text
CLEAR FLOOR SPACE AT DOOR STRIKE SIDE
AutoCAD SHX Text
NOTE: 1. EXTERIOR DOOR PRESSURE CANNOT EXCEED 8.5 LBS (GC TO DOOR PRESSURE TO MINIMUM ALLOWABLE BY AHJ). 2. INTERIOR DOOR PRESSURE CANNOT EXCEED 5 LBS. 3. 60% OF PUBLIC ENTRANCES MUST BE ACCESSIBLE. (100% IN CA)
AutoCAD SHX Text
SEE DETAIL 12 / ADA1.0
AutoCAD SHX Text
HANDRAIL & CURB
AutoCAD SHX Text
HANDRAIL & CURB
AutoCAD SHX Text
3" ± 1" HIGH WHEEL GUIDE
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
SEE NOTE 2
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
SEE NOTE 1
AutoCAD SHX Text
1 WHEN DOOR SWINGS ONTO LANDING 42" MIN. PLUS DOOR WIDTH
AutoCAD SHX Text
60" MIN. WHEN NO DOOR SWINGS ONTO LANDING
AutoCAD SHX Text
AS REQUIRED
AutoCAD SHX Text
BOTTOM LEVEL PLATFORM
AutoCAD SHX Text
INTERMEDIATE LEVEL PLATFORM
AutoCAD SHX Text
TOP PLATFORM
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
SEE NOTE
AutoCAD SHX Text
*
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
AS REQUIRED
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
NOTE: MAXIMUM HORIZONTAL DISTANCES OF EACH RAMP AND RUN VARY.
AutoCAD SHX Text
* WHEN DOOR SWINGS ONTO LANDING - 42" MIN. PLUS DOOR WIDTH.
AutoCAD SHX Text
WHEN NO DOOR SWINGS ONTO LANDING.
AutoCAD SHX Text
AS REQUIRED
AutoCAD SHX Text
NOTE 2: MAXIMUM HORIZONTAL DISTANCE OF GEACH RAMP AND RUN VARY
AutoCAD SHX Text
60" MIN. WHEN NO DOOR SWINGS ONTO LANDING
AutoCAD SHX Text
INTERMEDIATE LEVEL PLATFORM
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
NOTE 1: WHEN DOOR SWINGS ONTO LANDING 42" MIN. PLUS DOOR WIDTH
AutoCAD SHX Text
TOP PLATFORM
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
INTERMEDIATE LEVEL TURNING PLATFORM
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
AS REQUIRED
AutoCAD SHX Text
SEE NOTE 2
AutoCAD SHX Text
WHEEL GUIDE
AutoCAD SHX Text
GUIDE RAIL
AutoCAD SHX Text
GUIDE RAIL DETAIL
AutoCAD SHX Text
WHEEL GUIDE DETAIL
AutoCAD SHX Text
STRAIGHT RAMP RUN
AutoCAD SHX Text
RAMP WITH INTERMEDIATE SWITCH BACK PLATFORM
AutoCAD SHX Text
RAMP WITH TURNING PLATFORM
AutoCAD SHX Text
18" MIN. EXTERIOR AND INTERIOR BEYOND THE STRIKE EDGE OF A GATE OR DOOR ON THE SIDE TOWARD WHICH IT SWINGS. (24" REQUIRED IN CA FOR EXTERIOR DOORS)
AutoCAD SHX Text
RAMP LANDING AT DOORWAY
AutoCAD SHX Text
KEY NOTES
AutoCAD SHX Text
2 MAXIMUM HORIZONTAL DISTANCE OF EACH RAMP & RUN VARY
AutoCAD SHX Text
72" FOR CALIFORNIA & 60" FOR REST OF COUNTRY
AutoCAD SHX Text
3 HANDRAILS NOT REQUIRED ON WALKING SURFACES WITH RUNNING SLOPES LESS THAN 1:20.
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
CLEAR WIDTH OF ACCESSIBLE ROUTE
AutoCAD SHX Text
EDGE PROTECTION DETAIL
AutoCAD SHX Text
72" FOR CALIFORNIA & 60" FOR REST OF COUNTRY
AutoCAD SHX Text
72" FOR CALIFORNIA & 60" FOR REST OF COUNTRY
AutoCAD SHX Text
72" FOR CALIFORNIA & 60" FOR REST OF COUNTRY
AutoCAD SHX Text
72" FOR CALIFORNIA & 60" FOR REST OF COUNTRY
AutoCAD SHX Text
(1) VAN ACCESSIBLE STALL & (1) STANDARD ACCESSIBLE STALL
AutoCAD SHX Text
2% MAX. SLOPE
AutoCAD SHX Text
8.3% MAX.
AutoCAD SHX Text
8.3% MAX.
AutoCAD SHX Text
NOTE: 1:6 : 1:6 VAN ACCESSIBLE SPACES ARE REQUIRED. AISLE MUST BE ON PASSENGER SIDE ONLY. NOTE: : ADHERE TO LOCAL OR STATE MUNICIPALITY IF MORE RESTRICTIVE.
AutoCAD SHX Text
NOTE: PROVIDE WHEEL STOP WHERE SIDEWALK IS LESS THAN 6'-0" WIDE
AutoCAD SHX Text
ETC.
AutoCAD SHX Text
CODES, NOTICES, FINES,
AutoCAD SHX Text
THIS AREA IS FOR LOCAL
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
RESERVED
AutoCAD SHX Text
ACCESSIBLE
AutoCAD SHX Text
VAN
AutoCAD SHX Text
NOTE: LOCAL MUNICIPALITY MAY HAVE ADDITIONAL REQUIREMENTS FOR RAMPS THAT SHOULD BE REFERENCED.
AutoCAD SHX Text
DEPRESSED CURB RAMP AT ACCESSIBLE PARKING (TYP.)
AutoCAD SHX Text
DEPRESSED CURB RAMP
AutoCAD SHX Text
BOTTOM LANDING
AutoCAD SHX Text
RAMPS DOWN
AutoCAD SHX Text
WALKWAY <72" WIDE
AutoCAD SHX Text
1:12 MAX.
AutoCAD SHX Text
1:12 MAX.
AutoCAD SHX Text
RETAINING CURB (IF NECESSARY)
AutoCAD SHX Text
VAN-ACCESSIBLE STALL, 11' WIDE, 18' LONG LEFT OF ACCESS AISLE
AutoCAD SHX Text
PARKING AND AISLE SLOPE 2% MAX. IN ANY DIRECTION
AutoCAD SHX Text
DIAGONAL 3" STRIPES, 36" O.C. WHITE OR BLUE
AutoCAD SHX Text
WHEEL-STOP (AWAY FROM AISLE)
AutoCAD SHX Text
POST MOUNTED ISA SIGN WITH ADDITIONAL "VAN ACCESSIBLE" LANGUAGE
AutoCAD SHX Text
BOTTOM LANDING, 60" LONG, ELEVATION 2% SLOPE, WITH SMOOTH TRANSITION (NO 1/2 LIP)
AutoCAD SHX Text
36" SQUARE ISA PAVEMENT SIGN
AutoCAD SHX Text
REGULAR ACCESSIBLE STALL, 8' WIDE, 18' LONG (9' WIDE IN CA)
AutoCAD SHX Text
RAMP DOWN. USE LEAST POSSIBLE SLOPE, 8.3% MAX.
AutoCAD SHX Text
WALKWAY 4' CLEAR MIN.
AutoCAD SHX Text
POST MOUNTED ISA PARKING SIGN
AutoCAD SHX Text
NOTE: LOCAL MUNICIPALITY MAY HAVE ADDITIONAL REQUIREMENTS FOR RAMPS THAT SHOULD BE REFERENCED.
AutoCAD SHX Text
TYP. CURB CUT ELEVATIONS
AutoCAD SHX Text
DOWN 5%
AutoCAD SHX Text
+6.0"
AutoCAD SHX Text
+1.2" (0.0" PREFERRED)
AutoCAD SHX Text
0.0"
AutoCAD SHX Text
10% MAX SLOPE
AutoCAD SHX Text
DOWN 8.3%
AutoCAD SHX Text
+7.9"
AutoCAD SHX Text
+8.9"
AutoCAD SHX Text
DOWN 2%
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
CURB CUT AT ACCESSIBLE PARKING
AutoCAD SHX Text
SIDE FLARES SLOPED AT 10% MAX.
AutoCAD SHX Text
6" CURB
AutoCAD SHX Text
48" WIDE RAMP SLOPED AT 8.3% MAX.
AutoCAD SHX Text
2% CROSS SLOPE
AutoCAD SHX Text
CURB RAMPS NOT ALLOWED
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
BUILT-UP