MPR9500
Citation preview
9500 MPR TAT
ED 10
Optics WT- TEC Draft 50/72
22 HOUSEKEEPING TEST
The purpose of this test case is to test the housekeeping channels.
22.1 Test Configuration MPR has to be equipped with AUX peripheral unit (see ref. [VI]). The alarm polarities for input and output alarms to be taken into account for the test is the following:
Input Alarm Setup
Output Alarm Setup
9500 MPR TAT
ED 10
Optics WT- TEC Draft 51/72
22.2 Test Procedure • Enable the housekeeping connectors PIN • Connect the multimeter to the PIN direction output and set the instruments properly
for the test • Check the alarms • Connect the PIN direction input to the ground as shown in the figure above and act in
a way to open or close the circuit • Check the status of the alarm • Perform the test setting first the status of the alarms as normally closed and second as
normally open
22.3 Test Result The alarms will appears and disappears coherently with the settings applied.
22.4 Remark In case of output alarm the electrical characteristics are the following: open contact: 2V < |V|< 60V; |I| < 0.2mA closed contact: 0V < |V|< 2V; |I| < 50mA In case of input alarm the electrical characteristics are the following: open contact: 2V < |V|< 60 V; |I| < 0.2mA closed contract: 0V < |V|< 2 V; |I| < 50mA
23 REFERENCES [I] 9500 MPR 1.4.0 Technical Description Version 4.0 [II] ETSI EN 302 217-2-2 V1.2.3 (2007-09) and V1.1.3 [III] ITU-T G.703; ITU-T G.823 [IV] European Communities – Radio Spectrum Article 3.2 R&TTE Directive (1999/5/EC) [V] RFC 2544 [VI] User Manual - 9500 MPR-E Rel. 3.0.0----- [VII] ETSI Technical Summary – Rev. 6.2 [VIII] ITU-T G.707 [IX] ITU-T G.957 [X] ITU-T G.825 [XI] ITU-T G.783