Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
DWG NO.:
SCALE:
DWG CONTENTS:
1 OF 21
LPC #19-25588
80 WHITE STREET NEW YORK, NY 10014
LPC DOCKET #LPC-19-25588
MAY 10, 2018
SHEET 1 OF 21
PROPOSAL TO MODIFY STREET-FRONT BULKHEAD, AND ENLARGE AN EXISTING WINDOW OPENING ON CORTLANDT ALLEY FOR THE INSTALLATION OF A NEW ENTRANCE DOOR
N.T.S.
Hud
son
Str
eet
Wes
t Bro
adw
ay
Woo
ster
Stre
et
Green
e Stre
et
Canal Street
Walker Street
Grand Street
White Street
Broad
way
West Houston Street
1977–84
105 Hudson Street
1984–93
223 West Broadway1972–77
155 Wooster Street
1993–2016
38 Greene Street
2012–present
55 Walker Street
2018
80 White Street
1
2
3
4
5
6
Artists Space1972 until
today
⌛
DWG NO.:
SCALE:
DWG CONTENTS:
2 OF 21
LPC #19-25588
N.T.S.ARTISTS SPACE LOCATIONS SINCE 1972
DWG NO.:
SCALE:
DWG CONTENTS:
3 OF 21
LPC #19-25588
N.T.S.PROJECT LOCATION AND BACKGROUND
1. CURRENT PHOTO (2018)South Facade from south west corner on White Street
2. PROPERTY LOCATION80 White StreetTribeca East Historic District
DWG NO.:
SCALE:
DWG CONTENTS:
4 OF 21
LPC #19-25588
VIEWS OF STOREFRONT AND BULKHEAD UNDER CONSTRUCTION(JANURARY 2018) PER APPROVED PLANS UNDER LPC 18-2611 AND 19-8921
1. CURRENT PHOTO (2018)South Facade from south west corner on White Street
2. CURRENT PHOTO (2018)South Facade from south east corner on White Street
N.T.S.
ADJA
CENT
BUI
LDIN
G
CORTLANDT ALLEY
WHI
TE S
TREE
TW
HITE
STR
EET
16 CORTLANDT ALLEY
70 W
HITE
STR
EET
GRADEELEV. ± 0'-0"
1ST FLELEV. ± 3'-3"
DWG NO.:
SCALE:
DWG CONTENTS:
5 OF 21
LPC #19-25588
EXISTING FIRST FLOOR PLAN 3/32” = 1’-0”
Entry into building lobby and storefront
ADA lift
CORTLANDT ALLEY
WHI
TE S
TREE
T
ADJA
CENT
BUI
LDIN
G
WHI
TE S
TREE
T
16 CORTLANDT ALLEY
70 W
HITE
STR
EET
GRADEELEV. ± 0'-0"
VESTIBULEELEV. ± 0'-1"
1ST FLELEV. ± 3'-3"
DWG NO.:
SCALE:
DWG CONTENTS:
6 OF 21
LPC #19-25588
PROPOSED FIRST FLOOR PLAN 3/32” = 1’-0”
Proposed entry
Proposed entry into storefront
Entry into building lobbyProposed bulkhead extension
DWG NO.:
SCALE:
DWG CONTENTS:
7 OF 21
LPC #19-25588
HISTORIC TAX PHOTO OF SOUTH FACADE AND BULKHEAD (1940s) PHOTO OF SOUTH FACADE AND BULKHEAD DURING CONSTRUCTION (2018)
N.T.S.
WATER TOWER
1ST FLOORELEV. + 2'-3"
GRADEELEV. ± 0'-0"
CORTLANDT ALLEY
3RD FLOORELEV. + 33'-8"
4TH FLOORELEV. + 47'-4"
5TH FLOORELEV. + 59'-6"
6TH FLOORELEV. + 70'-8"
ROOFELEV. + 83'-2"
2ND FLOORELEV. + 19'-3"
TOP OF CORNICEELEV. + 86'-9"
WATER TOWER
1ST FLOORELEV. + 2'-3"
GRADEELEV. ± 0'-0"
CORTLANDT ALLEY
3RD FLOORELEV. + 33'-8"
4TH FLOORELEV. + 47'-4"
5TH FLOORELEV. + 59'-6"
6TH FLOORELEV. + 70'-8"
ROOFELEV. + 83'-2"
2ND FLOORELEV. + 19'-3"
TOP OF CORNICEELEV. + 86'-9"
EXISTING SOUTH FACADE ELEVATION PROPOSED SOUTH FACADE ELEVATION
DWG NO.:
SCALE:
DWG CONTENTS:
8 OF 21
LPC #19-25588
Proposed bulkhead extension
Location of bulkhead extension
3/32” = 1’-0”SOUTH FACADE ELEVATIONS
DWG NO.:
SCALE:
DWG CONTENTS:
9 OF 21
LPC #19-25588
1/4” = 1’-0”
EXISTING 1ST FLOOR BULKHEAD ELEVATION
EXISTING 1ST FLOOR BULKHEAD PLAN
Main entrance into building lobby
Main entrance into building lobby
Steps at entry to storefront
ADA Lift
ADA Lift
EXISTING BULKHEAD
DWG NO.:
SCALE:
DWG CONTENTS:
10 OF 21
LPC #19-25588
1/4” = 1’-0”
Main entrance into building lobby
Main entrance into building lobby
Proposed bulkhead extension; materials to match existing
ADA Lift
ADA Lift
PROPOSED 1ST FLOOR BULKHEAD ELEVATION
PROPOSED 1ST FLOOR BULKHEAD PLAN
Accessible entry into storefront
Extended railing to match existing
Extended railing to match existing
PROPOSED BULKHEAD
DWG NO.:
SCALE:
DWG CONTENTS:
11 OF 21
LPC #19-25588
CURRENT PHOTO (2018)West Facade and Cortlandt Alley from White Street
N.T.S.
DWG NO.:
SCALE:
DWG CONTENTS:
12 OF 21
LPC #19-25588
CURRENT PHOTO (2018)East Facade of 70 White Street and Cortlandt Alley from Walker Street
CURRENT PHOTO (2018)West Facade Door of 79 Walker Street from Cortlandt Alley
N.T.S.
DWG NO.:
SCALE:
DWG CONTENTS:
13 OF 21
LPC #19-25588
CURRENT PHOTO (2018)West Facade of 80 White Street from Cortlandt Alley showing windows installed in 2018
N.T.S.
DWG NO.:
SCALE:
DWG CONTENTS:
14 OF 21
LPC #19-25588
CURRENT PHOTO (2018)West Facade from Cortlandt Alley
CURRENT PHOTO (2018)West Facade from Cortlandt Alley
N.T.S.
Existing window opening proposed to be vertically enlarged for a new entrance
Existing window opening proposed to be vertically enlarged for a new entrance
GRADEELEV. ± 0'-0"
3RD FLOORELEV. + 33'-8"
4TH FLOORELEV. + 47'-4"
5TH FLOORELEV. + 59'-6"
6TH FLOORELEV. + 70'-8"
2ND FLOOR19'-3"
1ST FLOORELEV. + 2'-4"
TOP OF CORNICEELEV. + 86'-9"
ROOFELEV. + 83'-2"
WATER TOWER
DWG NO.:
SCALE:
DWG CONTENTS:
15 OF 21
LPC #19-25588
Existing 12x12 air intake louver in existing fire rated panelExisting 12x12 ventilation louver for gas meter in existing fire rated panel
3/32” = 1’-0”EXISTING WEST FACADE ELEVATION
Existing window opening proposed to be vertically enlarged for a new entrance
WATER TOWER
GRADEELEV. ± 0'-0"
3RD FLOORELEV. + 33'-8"
4TH FLOORELEV. + 47'-4"
5TH FLOORELEV. + 59'-6"
6TH FLOORELEV. + 70'-8"
2ND FLOOR19'-3"
1ST FLOORELEV. + 2'-4"
TOP OF CORNICEELEV. + 86'-9"
ROOFELEV. + 83'-2"
DWG NO.:
SCALE:
DWG CONTENTS:
16 OF 21
LPC #19-25588
3/32” = 1’-0”PROPOSED WEST FACADE ELEVATION
Relocated 12x12 air intake louver in existing fire rated panelExisting 12x12 ventilation louver for gas meter in existing fire rated panelNew entrance at vertically enlarged existing window opening
DWG NO.:
SCALE:
DWG CONTENTS:
17 OF 21
LPC #19-25588
1/4” = 1’-0”
PARTIAL SECTION SHOWING REMOVED MATERIALS PARTIAL ELEVATION SHOWING REMOVED MATERIALS
PARTIAL PLAN SHOWING REMOVED MATERIALS
Existing light fixture to remain
Area of brick to be removed down to sidewalk
Existing granite slab sidewalk to remain
Existing window, frame, sill, and trim, installed in 2018, to be removed
Existing window, frame, sill, and trim, installed in 2018, to be removed
Existing fire rated panel, grille, frame, and sill, to be removed
Existing light fixture to remain
Area of brick and stone to be removed
Existing window, frame, sill, and trim, installed in 2018, to be removed
Existing brick masonry
Existing stone belt course
Existing 12x12 air intake louver to be relocated
Existing stone
ENLARGED WEST ENTRY SHOWING REMOVALS
INTERIOR
EXTERIOR
Existing 12x12 ventilation louver for gas meter in existing fire rated panel to remain
ARTISTS
DWG NO.:
SCALE:
DWG CONTENTS:
18 OF 21
LPC #19-25588
1/4” = 1’-0”
PROPOSED WEST ENTRY SECTION PROPOSED WEST ENTRY ENLARGED ELEVATION
PROPOSED WEST ENTRY ENLARGED PLAN
Existing light fixture
Existing cellar window and sill
Existing granite slab sidewalkNew colored concrete threshold flush with sidewalk
Painted steel glazed entry doorPainted sign
Painted wood shutter
Steel framed transom light, painted.
Steel framed transom light, painted.
Existing light fixture
Cutout bracket sign, painted steel.
Cutout bracket sign, painted steel.
Steel framed entry door, painted.
Painted wood shutters
New flush mounted intercom
Painted wood shutters
INTERIOR
EXTERIOR
Steel framed entry door, painted.
Existing brick masonry
Existing stone
Existing brick masonry
New colored concrete threshold
Existing stone
ENLARGED WEST ENTRY SHOWING PROPOSAL
Existing 12x12 ventilation louver for gas meter in existing fire rated panel
Relocated 12x12 air intake louver in existing fire rated panel
N.T.S.
DWG NO.:
SCALE:
DWG CONTENTS:
19 OF 21
LPC #19-25588
Existing 2x12 air intake louver in existing fire rated panel, to be relocated
Existing window opening proposed to be vertically changed for new entrance
CURRENT PHOTO (2018)
N.T.S.
DWG NO.:
SCALE:
DWG CONTENTS:
20 OF 21
LPC #19-25588
RENDERING WITH OUTER SHUTTERS CLOSED
PROPOSED WEST ENTRY WITH SHUTTERS CLOSED
Cutout bracket sign, painted steel.
Steel framed transom light, painted.
Painted wood shutter
N.T.S.
DWG NO.:
SCALE:
DWG CONTENTS:
21 OF 21
LPC #19-25588
RENDERING WITH OUTER SHUTTERS OPEN
PROPOSED WEST ENTRY WITH SHUTTERS OPEN
Cutout bracket sign, painted steel.
Steel framed transom light, painted.
Steel framed entry doors, painted.