SPECIFICATION DATA
Put Bar Code Here
63-1372-02
VFD CORE Wiring Diagrams and Dimensional Drawings: All Frame Sizes
VFD CORE
460 VoltageFrame Size A: 1-10 HPFrame Size B: 15-25 HPFrame Size C: 30-50 HPFrame Size D: 60-125 HP
208/230 VoltageFrame Size A: 1-7.5 HPFrame Size B: 10-20 HPFrame Size C: 25-40 HPFrame Size D: 50-60 HPFrame Size E: 75-125 HP
CONTENTSVFD CORE Wiring Diagrams (for every size) ................................................................................. 2
VFD CORE Dimensional Drawings ................................................................................................ 3
Frame A NEMA1 3 Contactor .................................................................................................... 3
Frame B NEMA1 3 Contactor .................................................................................................... 4
Frame C NEMA1 3 Contactor .................................................................................................... 5
Frame D NEMA1 3 Contactor .................................................................................................... 6
Frame E NEMA1 3 Contactor..................................................................................................... 7
VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES
63-1372—02 2
Fig. 1. NEMA1, 3 Contactor Bypass Wiring Diagram
M33716
NO
TE
1: IF C
US
TOM
ER
SA
FE
TY
INT
ER
LOC
K IS
US
ED
, RE
MO
VE
J1.
ALL W
IRIN
G: U
SE
CO
PP
ER
WIR
E O
NLY
SU
ITAB
LE F
OR
MIN
. 75 DE
G. C
, F
IELD
WIR
ING
, NE
C C
LAS
S 1. M
OTO
R A
ND
FE
ED
ER
WIR
E S
IZE
MU
ST
B
E IN
AC
CO
RD
AN
CE
WIT
H N
EC
.
FIE
LD W
IRE
WIR
E IN
SID
E C
/PN
L
OP
TIO
N
VF
D S
TAR
T C
OM
MA
ND
0-20 m
A
0-10 V
DC
SH
IELD
X
GN
D
GN
D
RO 2, FAULT
RO 1, RUN
RO 3, READY
M
VF
DS
T
L1
/1.41
L3/1.41
L1
T1
TB
T2
TB
T3
TB
.57T
3
T2
T1
L3 L2 L1
OL1
.53D
OC
L3L2
L1
T3
T2
T1
.57 BC
L3 L2 L1
T3
T2
T1
L2L3
00X0
CO
NT
RO
L TR
AN
SF
OR
ME
RT
1
OF
FT
ES
T
SS
1
000X
J1
L1/1.40
L3/1.40
21
F
U4
21
F
U5
21
F
U6
1T
B3
TB
FF
SIV
FD
BY
PAS
S
A2
A1
D
IC
.57
A2
A1
D
OC
BC
3
54 9
12
DC COMDC DOM+ 24 V+ 24 VFWDREVMI 1MI 2MI 3MI 4MI 5MI 6MI 7MI 8SHD+ 10 V/20 mAAVI 1 0-10 V/ 0-20 mAACI, 0-20 mA / 0-10 VAVI 2, 0-+10VACM, ANALOG COMMSHDRA 1, 250 VAC/6 ARB 1, 30 VDC/6 ARC 1RA 2, 250 VAC/5 ARC 2RA 3, 250 VAC/5 ARC 3, 30 VDC/5 AAFM 1, A0, 0-10 V/ 0-20 mAACM, ANALOG COMMAFM 2, A0, 0-10 V/0-20 mASHD
NO
T A
LL VF
D C
ON
TR
OL I/O
SH
OW
NC
ON
SU
LT V
FD
MA
NU
AL F
OR
AD
DIT
ION
AL C
ON
TR
OL I/O
CO
NS
ULT
VF
D M
AN
UA
L FO
R S
ER
IAL C
OM
M
CO
RE
DR
IVE
R(L1)
S(L2)
T(L3)
U(T
1)V
(T2)
W(T
3)
MO
TO
RH
PR
PM
AM
P
.51
DIC
L3 L2 L1
T3
T3
T2
T2
T1
T1
LINE
VO
LTAG
E,
3 PH
AS
E, 60 H
ZG
ND
DIS
1M
AIN
FU
SE
D D
ISC
.F
U1, F
U2, F
U3,
CLA
SS
J, TIM
E D
ELAY
AN
AL
OG
CO
MM
ON
VF
D S
PE
ED
RE
FE
RE
NC
EU
SE
2 CO
ND
UC
TOR
SH
D,
TW
IST
ED
PAIR
WIR
E G
ND
S
HD
AT F
IELD
EN
D
0-10
VD
C, 0
-20m
A
SE
E N
OT
E 1
000X
X2
X1
LT1
X000
.11
OL1
.53
DO
C
A2
A1
B
C6
78
X2
X1
LT2
DR
IVE
INP
UT
CO
NTA
CTO
R
CU
STO
ME
R S
UP
PLIE
DF
RE
EZ
E/F
IRE
/SM
OK
E
INT
ER
LOC
K
CLA
SS
CC
PR
IMA
RY
FU
SE
CLA
SS
CC
P
RIM
AR
Y F
US
E
250V, M
IDG
ET
S
EC
ON
DA
RY
FU
SE
DR
IVE
OU
TP
UT
CO
NTA
CTO
R
BY
PAS
SC
ON
TAC
TOR
VF
D R
UN
BY
PAS
S R
UN
Y G
VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES
3 63-1372—02
Fig. 2. Frame Size A, NEMA1 , 3 Contactor
VFD Run
Bypass
Off Test
VFD
M33712
7-15/32(190)
9-19/64(236) 10-5/8
(270)
8-13/32(213)
5-1/8(130)
34(864)
8-15/16(227)
22(559)
I ON
O O
FF
Frame Size
HP and Voltage
Configuration
Dimensions Weight (Lb.)208/230 Vac 460 Vac W1 W2 H1 H2 D1 D2
A 1-7.5 HP 1-10 HP 3 Contactor with Fused Disconnect 8.9 8.4 34 22 10.6 9.3 37
VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES
63-1372—02 4
Fig. 3. Frame Size B, NEMA1 , 3 Contactor
VFD Run
Bypass
Off Test
VFD
M33713
9-43/64(245)
±1/64 (1) 11-1/2
(292)±
1/64 (1)
48(1,219)
±1/64 (1)
8-15/64(209)
±1/64 (1)
11-7/8(302)
±1/64 (1) 7-31/64
(190)±
1/64 (1)
12-7/16(316)
±1/64 (1)
Frame Size
HP and Voltage
Configuration
Dimensions Weight (Lb.)208/230 Vac 460 Vac W1 W2 H1 H2 D1 D2
B 15-20 HP 10-20 HP 3 Contactor with Fused Disconnect 12.4 11.8 48 30 11.5 9.66 67
VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES
5 63-1372—02
Fig. 4. Frame Size C, NEMA1, 3 Contractor
Frame Size
HP and Voltage
Configuration
Dimensions Weight (Lb.)208/230 Vac 460 Vac W1 W2 H1 H2 D1 D2
C 25-40 HP 30-50 HP 3 Contractor with Fused Disconnect 12.4 11.8 48 30 11.5 9.66 83
M33714
12-7/16(316)
±1/64 (1)
9-43/64(245)
±1/64 (1) 11-1/2(292)
±1/64 (1)
11-7/8(302)
±1/64 (1)9-7/8(251)
±1/64 (1)
9-1/32(229)
±1/64 (1)
48(1,219)
±1/64 (1)
30(762)
±1/64 (1)
VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES
63-1372—02 6
Fig. 5. Frame Size D, NEMA1, 3 Contactor
M33715
32-3/32(815)
19-9/16(497) 13-5/16
(338)
11-29/64(291)
53-1/2(1359)
11-7/8(300)
FR
AM
E_D
21(533)
19(483)13-1/64
(331)
FRAME_D
Frame Size
HP and Voltage
Configuration
Dimensions Weight (Lb.)208/230 Vac 460 Vac W1 W2 H1 H2 D1 D2
D 50-60 HP 60-125 HP 3 Contactor with Fused Disconnect 21 19.5 53.5 32.08 11.4 13.3 193
VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES
7 63-1372—02
Fig. 6. Frame Size E, NEMA1, 3 Contactor
M33834
66-1/2(1,689)
25(635)
23(483)14-9/16
(370)
FRAME_E
12-45/64(323)
14-7/16(367) 16-1/4
(413)
43-59/64(1,116)
Frame Size
HP and Voltage
Configuration
Dimensions
208/230 Vac 460 Vac W1 W2 H1 H2 D1 D2
E 75-125 HP -- 3 Contactor with Fused Disconnect 25 23 66.5 43.9 16.2 14.4
VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES
Automation and Control SolutionsHoneywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
customer.honeywell.com
® U.S. Registered Trademark© 2012 Honeywell International Inc.63-1372—02 M.S. Rev. 09-12 Printed in United States
By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys’ fees, arising out of, or resulting from, any modification to the literature by you.