8
SPECIFICATION DATA 63-1372-02 VFD CORE Wiring Diagrams and Dimensional Drawings: All Frame Sizes VFD CORE 460 Voltage Frame Size A: 1-10 HP Frame Size B: 15-25 HP Frame Size C: 30-50 HP Frame Size D: 60-125 HP 208/230 Voltage Frame Size A: 1-7.5 HP Frame Size B: 10-20 HP Frame Size C: 25-40 HP Frame Size D: 50-60 HP Frame Size E: 75-125 HP CONTENTS VFD CORE Wiring Diagrams (for every size) ................................................................................. 2 VFD CORE Dimensional Drawings ................................................................................................ 3 Frame A NEMA1 3 Contactor .................................................................................................... 3 Frame B NEMA1 3 Contactor .................................................................................................... 4 Frame C NEMA1 3 Contactor .................................................................................................... 5 Frame D NEMA1 3 Contactor .................................................................................................... 6 Frame E NEMA1 3 Contactor..................................................................................................... 7

63-1372—02 - VFD CORE Wiring Diagrams and … · vfd core wiring diagrams and dimensional drawings: all frame sizes 63-1372—02 2 fig. 1. nema1, 3 contactor bypass wiring diagram

  • Upload
    vantruc

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

SPECIFICATION DATA

Put Bar Code Here

63-1372-02

VFD CORE Wiring Diagrams and Dimensional Drawings: All Frame Sizes

VFD CORE

460 VoltageFrame Size A: 1-10 HPFrame Size B: 15-25 HPFrame Size C: 30-50 HPFrame Size D: 60-125 HP

208/230 VoltageFrame Size A: 1-7.5 HPFrame Size B: 10-20 HPFrame Size C: 25-40 HPFrame Size D: 50-60 HPFrame Size E: 75-125 HP

CONTENTSVFD CORE Wiring Diagrams (for every size) ................................................................................. 2

VFD CORE Dimensional Drawings ................................................................................................ 3

Frame A NEMA1 3 Contactor .................................................................................................... 3

Frame B NEMA1 3 Contactor .................................................................................................... 4

Frame C NEMA1 3 Contactor .................................................................................................... 5

Frame D NEMA1 3 Contactor .................................................................................................... 6

Frame E NEMA1 3 Contactor..................................................................................................... 7

VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES

63-1372—02 2

Fig. 1. NEMA1, 3 Contactor Bypass Wiring Diagram

M33716

NO

TE

1: IF C

US

TOM

ER

SA

FE

TY

INT

ER

LOC

K IS

US

ED

, RE

MO

VE

J1.

ALL W

IRIN

G: U

SE

CO

PP

ER

WIR

E O

NLY

SU

ITAB

LE F

OR

MIN

. 75 DE

G. C

, F

IELD

WIR

ING

, NE

C C

LAS

S 1. M

OTO

R A

ND

FE

ED

ER

WIR

E S

IZE

MU

ST

B

E IN

AC

CO

RD

AN

CE

WIT

H N

EC

.

FIE

LD W

IRE

WIR

E IN

SID

E C

/PN

L

OP

TIO

N

VF

D S

TAR

T C

OM

MA

ND

0-20 m

A

0-10 V

DC

SH

IELD

X

GN

D

GN

D

RO 2, FAULT

RO 1, RUN

RO 3, READY

M

VF

DS

T

L1

/1.41

L3/1.41

L1

T1

TB

T2

TB

T3

TB

.57T

3

T2

T1

L3 L2 L1

OL1

.53D

OC

L3L2

L1

T3

T2

T1

.57 BC

L3 L2 L1

T3

T2

T1

L2L3

00X0

CO

NT

RO

L TR

AN

SF

OR

ME

RT

1

OF

FT

ES

T

SS

1

000X

J1

L1/1.40

L3/1.40

21

F

U4

21

F

U5

21

F

U6

1T

B3

TB

FF

SIV

FD

BY

PAS

S

A2

A1

D

IC

.57

A2

A1

D

OC

BC

3

54 9

12

DC COMDC DOM+ 24 V+ 24 VFWDREVMI 1MI 2MI 3MI 4MI 5MI 6MI 7MI 8SHD+ 10 V/20 mAAVI 1 0-10 V/ 0-20 mAACI, 0-20 mA / 0-10 VAVI 2, 0-+10VACM, ANALOG COMMSHDRA 1, 250 VAC/6 ARB 1, 30 VDC/6 ARC 1RA 2, 250 VAC/5 ARC 2RA 3, 250 VAC/5 ARC 3, 30 VDC/5 AAFM 1, A0, 0-10 V/ 0-20 mAACM, ANALOG COMMAFM 2, A0, 0-10 V/0-20 mASHD

NO

T A

LL VF

D C

ON

TR

OL I/O

SH

OW

NC

ON

SU

LT V

FD

MA

NU

AL F

OR

AD

DIT

ION

AL C

ON

TR

OL I/O

CO

NS

ULT

VF

D M

AN

UA

L FO

R S

ER

IAL C

OM

M

CO

RE

DR

IVE

R(L1)

S(L2)

T(L3)

U(T

1)V

(T2)

W(T

3)

MO

TO

RH

PR

PM

AM

P

.51

DIC

L3 L2 L1

T3

T3

T2

T2

T1

T1

LINE

VO

LTAG

E,

3 PH

AS

E, 60 H

ZG

ND

DIS

1M

AIN

FU

SE

D D

ISC

.F

U1, F

U2, F

U3,

CLA

SS

J, TIM

E D

ELAY

AN

AL

OG

CO

MM

ON

VF

D S

PE

ED

RE

FE

RE

NC

EU

SE

2 CO

ND

UC

TOR

SH

D,

TW

IST

ED

PAIR

WIR

E G

ND

S

HD

AT F

IELD

EN

D

0-10

VD

C, 0

-20m

A

SE

E N

OT

E 1

000X

X2

X1

LT1

X000

.11

OL1

.53

DO

C

A2

A1

B

C6

78

X2

X1

LT2

DR

IVE

INP

UT

CO

NTA

CTO

R

CU

STO

ME

R S

UP

PLIE

DF

RE

EZ

E/F

IRE

/SM

OK

E

INT

ER

LOC

K

CLA

SS

CC

PR

IMA

RY

FU

SE

CLA

SS

CC

P

RIM

AR

Y F

US

E

250V, M

IDG

ET

S

EC

ON

DA

RY

FU

SE

DR

IVE

OU

TP

UT

CO

NTA

CTO

R

BY

PAS

SC

ON

TAC

TOR

VF

D R

UN

BY

PAS

S R

UN

Y G

VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES

3 63-1372—02

Fig. 2. Frame Size A, NEMA1 , 3 Contactor

VFD Run

Bypass

Off Test

VFD

M33712

7-15/32(190)

9-19/64(236) 10-5/8

(270)

8-13/32(213)

5-1/8(130)

34(864)

8-15/16(227)

22(559)

I ON

O O

FF

Frame Size

HP and Voltage

Configuration

Dimensions Weight (Lb.)208/230 Vac 460 Vac W1 W2 H1 H2 D1 D2

A 1-7.5 HP 1-10 HP 3 Contactor with Fused Disconnect 8.9 8.4 34 22 10.6 9.3 37

VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES

63-1372—02 4

Fig. 3. Frame Size B, NEMA1 , 3 Contactor

VFD Run

Bypass

Off Test

VFD

M33713

9-43/64(245)

±1/64 (1) 11-1/2

(292)±

1/64 (1)

48(1,219)

±1/64 (1)

8-15/64(209)

±1/64 (1)

11-7/8(302)

±1/64 (1) 7-31/64

(190)±

1/64 (1)

12-7/16(316)

±1/64 (1)

Frame Size

HP and Voltage

Configuration

Dimensions Weight (Lb.)208/230 Vac 460 Vac W1 W2 H1 H2 D1 D2

B 15-20 HP 10-20 HP 3 Contactor with Fused Disconnect 12.4 11.8 48 30 11.5 9.66 67

VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES

5 63-1372—02

Fig. 4. Frame Size C, NEMA1, 3 Contractor

Frame Size

HP and Voltage

Configuration

Dimensions Weight (Lb.)208/230 Vac 460 Vac W1 W2 H1 H2 D1 D2

C 25-40 HP 30-50 HP 3 Contractor with Fused Disconnect 12.4 11.8 48 30 11.5 9.66 83

M33714

12-7/16(316)

±1/64 (1)

9-43/64(245)

±1/64 (1) 11-1/2(292)

±1/64 (1)

11-7/8(302)

±1/64 (1)9-7/8(251)

±1/64 (1)

9-1/32(229)

±1/64 (1)

48(1,219)

±1/64 (1)

30(762)

±1/64 (1)

VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES

63-1372—02 6

Fig. 5. Frame Size D, NEMA1, 3 Contactor

M33715

32-3/32(815)

19-9/16(497) 13-5/16

(338)

11-29/64(291)

53-1/2(1359)

11-7/8(300)

FR

AM

E_D

21(533)

19(483)13-1/64

(331)

FRAME_D

Frame Size

HP and Voltage

Configuration

Dimensions Weight (Lb.)208/230 Vac 460 Vac W1 W2 H1 H2 D1 D2

D 50-60 HP 60-125 HP 3 Contactor with Fused Disconnect 21 19.5 53.5 32.08 11.4 13.3 193

VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES

7 63-1372—02

Fig. 6. Frame Size E, NEMA1, 3 Contactor

M33834

66-1/2(1,689)

25(635)

23(483)14-9/16

(370)

FRAME_E

12-45/64(323)

14-7/16(367) 16-1/4

(413)

43-59/64(1,116)

Frame Size

HP and Voltage

Configuration

Dimensions

208/230 Vac 460 Vac W1 W2 H1 H2 D1 D2

E 75-125 HP -- 3 Contactor with Fused Disconnect 25 23 66.5 43.9 16.2 14.4

VFD CORE WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS: ALL FRAME SIZES

Automation and Control SolutionsHoneywell International Inc.

1985 Douglas Drive North

Golden Valley, MN 55422

customer.honeywell.com

® U.S. Registered Trademark© 2012 Honeywell International Inc.63-1372—02 M.S. Rev. 09-12 Printed in United States

By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys’ fees, arising out of, or resulting from, any modification to the literature by you.