Fortis Security Products 6000-RT Remote Teller System
Installation and Service Manual
Table Of Contents
6000RT Customer and Teller Dimensional Specifications Pg-1 Customer Service Door Removal Pg-2 Typical Installation Drawing Pg-3 6000RT Customer Island Detail Pg-4 Customer Mounting and Electrical Information Pg-5 Customer Turbine Installation Pg-7 Customer Audio Connections Pg-8 6000RT Teller Installation Drawings Pg-9 Teller Control Set-Up Pg-13 System Tubing Connections Pg-16 System Operational Sequence Pg-17 System Electrical Drawings Pg-18 Care and Maintenance Pg-22 Lane Station Installation Pg-23 Camera Installation Pg-24 Customer Part Breakdown Pg-25 Teller Part Breakdown Pg-29
13
5 16"
461316"
13
1 16"
12
3 4"
715 16
"
20"
58316"
12
5 8"
6000
RT C
USTO
MER
UN
IT60
00RT
TELL
ER U
NIT
1
REMOVE TWO SCREWS
TURN CCWTO UNLOCK
PULL OUT ON THE BOTTOMOF PANEL AND THENDOWN TO REMOVE.BECAREFUL OF THE WIRINGTHAT IS ATTACHED TO THEBACK OF THE PANEL
REMOVING SERVICE PANELS
PULL OUT ON THE BOTTOMOF PANEL AND THENDOWN TO REMOVE.BECAREFUL OF THE WIRINGTHAT IS ATTACHED TO THEBACK OF THE FRONT PANEL
LOCK VIEW
2
DR
IVE-
UP S
YSTE
M V
ERTI
CAL
SECT
ION
3
61 2
"
16"
3 34 "
5 18 "
7 12 "
10 14 "
97 16
"
CARRIER TUBE CENTER LINE
1/4" DIAMETER CONCRETE ANCHORS (4) PLCS.
26" 26"
6"
711 16
"
1 1116 "
3 18 "
71 4
"
13 4
"
4" BOLLARD(2) PLCS.
ELECTRICAL CONDUITLOCATION
IT IS RECOMMENDED THAT THE CONDUIT THAT HAS THE 120 VOLT 20 AMP CIRCUITCOME UP INTO THE BOTTOM OF A JUNCTION BOX THAT IS MOUNTED FLAT ON THE ISLAND.THEN A FLEXIBLE CONDUIT CAN BE RAN THRUTHE BASE OF THE UNIT TO THE JUNCTION BOX WHICH IS TO BE MOUNTED TO THE INSIDE OF THE RIGHT SIDE PANEL BELOW THE MOTOR ASSEMBLY.MAKE SURE THE OUTLET DOES NOT INTERFERE WITH THE REMOVAL AND INSTALLATION OF THE TURBINE ASSEMBLY.
TRAFFIC FLOW >>>>>>>>>
6000RT CUSTOMERMOUNTING LOCATIONS
TRAFFIC FLOW >>>>>>>>>
CONDUIT AND BOLLARD LOCATIONSCURB
4
Mounting the Customer Unit Locate Customer Unit on Island per detailed drawing. The front of the unit should be five inches from the front of the curb. Remove the turbine box by removing the flex hoses and lift out of unit. Mark the location of the four mounting holes. Using four 3/8 “ dia concrete anchors secure customer unit to island. Before final tightening of base anchors check level of unit front to back and left to right. Make sure unit is not twisted once fully tighten down to island
Electrical Connections The main power connection is a 120V 20A circuit using a Nema L5-20P cord end. The electrician should install an outlet for this style cord end in a junction box that is mounted to the inside of the right side of the cabinet. Make sure that this junction box and outlet do not interfere with the removal and installation of the Turbine Assembly. Note – If you are connecting conduits to the top of the unit. DO NOT CUT ANY HOLES IN THE TOP. REMOVE THE TWO PLUGS IN THE TOP. THESE HOLES ARE TAPPED SO THAT A ½” CONDUIT CONNECTOR CAN BE THREADED INTO PLACE. IT IS IMPORTANT THAT YOU ONLY USE THESE HOLES. THE UNDERNEATH OF THE TOP IS CONSTRUCTED WITH A HAS A AIR MANIFOLD MADE INTO IT. CUUTING INTO THE TOP WILL MAKE THE UNIT UN-USABLE! Each unit is shipped with a field wiring harness. The harness has eight color coded wires which are to be connected to the field wiring cable that runs between each station. Connect these wires color for color.
5
6000RT ELECTRICAL INFORMATIONTHREADED CONDUIT PORTSFOR OVERHEAD ELECTRICAL INSTALLATION. THESE PORTS ARE THREADED FOR 1/2" CONDUIT CONNECTORS. DO NOT CUT HOLES OR TRY TO ENLARGETHESE PORTS. THE UNDER SIDE OF THETOP HAS AN AIR MANIFOLD MOLDEDINTO IT. CUTTING THE TOP IN ANYWAY MAY RESULT IN AN AIR LEAK
E
OUTLET BOX SHOULD BE MOUNTED15 INCHES FROM THE INSIDE OF THE BASE TO THE BOTTOM OF THE BOX. BOX SHOULD BE MOUNTED AGAINST THE INSIDE OF THE RIGHT-SIDE PANEL WITH IT AGAINST THE INSIDE OF THE FRONT FLANGE.BOX CAN NOT BE ANY DEEPER THAN 1 3/4 INCHES. YOU WILL HAVE TROUBLE GETTING THE TURBINE ASSY IN AND OUT IF THE ELECTRICAL BOX IS INSTALLED INCORRECTLY!
JUNCTION BOX
ELECTRICAL CIRCUIT - 120 VOLT 20AMP DEDICATED CIRCUIT.REQUIRES AN L5-20 RECEPTACLE
6
F
TURBINE INSTALLATION
ONCE THE TURBINE IS INSTALLEDTHE HOSES WILL CONNECT AS THEY LINE UP. THE BACK HOSE GOESTO THE BACK PORT AND THE FRONT HOSE GOES TO THE FRONT PORT
WHEN INSTALLING TURBINEMAKE SURE THE FASTENERSON THE BOTTOM OF THETURBINE DROP DOWN INTOTHESE HOLES.
MAKE SURE THE BACK LEFT ANCHORDOES NOT KEEP THE TURBINE BOXFROM SETTING FLAT ON THE BOTTOMOF THE UNIT. 7
Audio System Connections The microphones, speaker, and call buttons are wired into the main harness and the pigtail is located near the electrical panel. The microphone wires (two shielded cables): Positive (red) negative (black) and common (bare) The speaker wires ( red and black wires): Positive (red) and negative (black) The call button wires (blue and white): Signal (blue) and common (white)
8
3100RT/ 5000RT/ 6000RT MANUAL TELLER UNIT
SYSTEM BUTTON WILL BE ILLUMINATED WHENSYSTEM IS READY FOR USE
RECALL BUTTON WILL BEILLUMINATED WHEN RECALLOR CUSTOMER SEND SEQUENCEIS ACTIVE.
INFORMATION AND SET-UP SCREEN
9
VENT TUBE
APPLY A SMALL AMOUNTOF SILICONE AROUND THEINSIDE OF THE EXPANDEDEND BEFORE CONNECTINGTO TERMINAL VENT PORTIF TERMINAL IS BEING USEDWITH A 3100 RT CUSTOMERUNIT THIS PORT IS A PRESSUREPORT AND MUST HAVE A GOOD SEAL.
IF LONGER CARRIER AND VENT TUBES ARE NEEDEDCONTACT FORTIS SECURITY PRODUCTS FOR AVAILABILITY
INSTALL TUBES AS SHOWNIF TUBES NEED TO BE TRIMMEDCUT THEM BEFORE INSTALLING ON TELLER TERMINAL
MOUNTING HARDWARE AND GASKET PACKAGED SEPARATELY INSTALL WIRE MOLD CENTERED
BEHIND CARRIER TUBE. LOCATE SOTHAT IT LINES UP OVER HOLE IN REAR HOUSING. THIS WILL SERVE ASA WIRE CHASE FOR YOUR CONTROL CABLE
WIRE MOLDPEEL AND STICK MOLDINGON BEHIND CARRIER TUBE
TELLER INSTALLATION INSTRUCTIONS
10
A BA
C
MANUAL TELLER WALL MOUNT INSTALLATIONA- ANCHOR BRACKET TO WALL WITH LAG-SCREWS. MAKESURE THERE IS BLOCKING IN THE WALL TO SUPPORT WEIGHTOF TELLER UNIT
B- TELLER HEIGHT CAN BE ADJUSTED UP OR DOWN BY LOOSENING THE U CLAMPS AND SLIDING TELLER TO THE CORRECT HEIGHT. TIGHTEN U CLAMPS ONCE ADJUSTED
C- TELLER UNIT CAN BE ADJUSTED IN AND OUT BY LOOSENINGTHESE BOLTS. TIGHTEN ONCE TELLER IS IN PROPER LOCATION
11
CARRIER TUBE
THIS TUBE IS A VENT TUBEWHEN USED WITH A 5000RT/6000RT CUSTOMERSTATIONWHEN THIS TELLER IS USED WITH A 3100 CUSTOMER STATION IT IS A PRESSURE PORTTHAT MUST BE CONNECTED TO THE REMOTE TURBINEPRESSURE PORT.
12
9/64" ALLEN WRENCH ISNEEDED TO REMOVE FOURSCREWS SECURING THE FRONTPANEL ON THE TELLER UNIT
A
B
(A) FIELD WIRING CONNECTOR(B) DOOR SWITCH CONNECTOR
TO ADJUST PARAMETERS BENDA SMALL PAPERCLIP AS SHOWNAND INSERT THE SMALL END THRUTHE APPROPRIATE SLOT (DRAWINGON THE RIGHT SHOWS A PICTURE OF THE CONTROL MODULE KEYS THATARE HIDDEN BEHIND THE ACCESS SLOTS)
*DO NOT USE A POINTED OBJECT!
MANUAL TELLER CONTROL SET-UP
THE POWER FOR THE CONTROL MODULEIS 24VDC. THIS POWER IS SUPPLIED THRUTHE 8 CONDUCTOR CONTROL CABLE ANDCOMES FROM THE CUSTOMER UNIT. 13
F
PRESS HERE TO GET TOSET-UP SCREEN "1"
PRESS HERE UNTILPARAMETER IS BLINKINGPRESS HERE ONCE PARAMETER IS BLINKINGTHIS WILL TAKE YOU TO TIMER SCREEN
T1 X S +T3 X S +T4 X S +T5 X S +
PRESS HERE TO SCROLL TO THE TIMER THAT NEEDS ADJUSTING
ONCE THE APPROPRIATE TIMERIS BLINKING PRESS HERE
T3 X S +I1 06.500I2 +0□ T:00.000
WHEN THIS SCREEN APPEARSTHE FIRST 0 IN THE I1 LINE WILLBE BLINKING. PRESS HERE TO CHANGE VALUE
T3 X S +I1 06.500I2 +0□ T:00.000
PARAMETER ADJUSTMENT PROCEDURE
5000RT-MANTELLERSYSTEM READY2015
TRANSACTIONS0000000000
PASSWORD ↑STOP RUN √PARAMETER...INFO ↓
START-UP SCREEN STAYS ON FOR 10 SECONDS
NORMAL SCREEN WHENIN RUN MODE SET-UP SCREEN "1"
TIMER SCREEN
PRESS HERE TO MOVELEFT AND RIGHT PRESS HERE TO INCREASE
OR DECREASE THE VALUEWHERE THE CURSOR IS
14
ONCE YOU HAVE THE VALUESET PRESS HERE TO SAVE.
PRESS HERE TO GO BACK TOTHE TIMER LIST AFTER SAVING CHANGEOR A TOTAL OF 3 TIMES TO GET BACK TO THE TRANSACTION SCREEN
T3 X S +I1 06.500I2 +0□ T:00.000
T1 X S +T3 X S +T4 X S +T5 X S +
TIMER LIST
C1 N +S 00001
□ C:00000
PARAMETER ADJUSTMENT PROCEDURE
TIMER SCREEN
T3 X S +I1 06.500I2 +0□ T:00.000
TIMER SCREEN
TIMERS AND PARAMETERST1 - DO NOT CHANGET3 - OUTBOUND RUN TIMET4 - DO NOT CHANGET5 - INBOUND RUN TIMET7 - DO NOT CHANGET8 - DO NOT CHANGET9 - DO NOT CHANGET11 - DO NOT CHANGET12 - DO NOT CHANGET15 - ANTI-CONDENSATION START DELAY*T16 - ANTI-CONDENSATION SETTINGS - I1 = BLOWER ON TIME IN SECONDS
I2 = OFF TIME IN MINUTES BETWEEN BLOWER PULSES. FACTORY SETTINGIS I1 = 4 (SECONDS) I2 = 90 (MINUTES) THIS FEATURE IS ONLY ACTIVEWHEN SYSTEM SWITCH IS OFF*
PARAMETERSC1 = ANTI-CONDENSATION ON OR OFF (00001 = OFF 00000 = ON)*C2 = AUTOMATIC TEST CYCLE ON OR OFF (00001 = OFF 00000 = ON) THIS FEATUREIS ONLY ACTIVE WHEN SYSTEM SWITCH IS OFF*C5 - DO NOT CHANGEC12 - DO NOT CHANGEC15 - DO NOT CHANGE
WHEN USING THE TEST CYCLE FUNCTION REMEMBER TO SET C2 TO 00000 AND TURN THE SYSTEM SWITCH OFF. WHEN CYCLE TEST IS COMPLETE CHANGE C2 BACK TO 00001 ANDCHANGE THE SYSTEM SWITCH TO ON FOR NORMAL OPERATION (NOT AVAILABLE ON 3100 MODEL SYSTEM)* INDICATES FEATURE THAT IS NOT AVAILABLE ON 3100 MODEL
PARAMETER SCREEN
THE PARAMETER SCREEN WILL ADJUST JUST LIKE A TIMERWITH THE EXCEPTION THAT YOU ARE CHANGING THE VALUEOF "S" INSTEAD OF I1.
15
Tubing Installation
Customer Tubing Connections Clear tubing attaches to the top of the customer unit using the provided TU-12 adapter there is an oring on the tube stub up on the customer unit. Use Vaseline to lubricate this oring before installing collar. At the top of the clear tube use the trim ring (TU-009) at the ceiling opening and the TU-19 adapter to attach the clear tubing to the PVC (TU-10 when attaching to steel tubing). Make sure that you seal the adapters to the tubing by applying a clear silicone around each end of the adapters after they are installed.
Teller Tubing Connections Use the TU-11 to attach the steel tube coming from the top of the teller unit to the PVC tubing. (a steel clamp sleeve TU-014 when attaching to steel tubing)
16
System Operational Sequence
Teller Send- 1. Close Teller Door to send carrier. 2. Vacuum turbine runs for a preset amount of time. 3. Customer door opens.
Teller Recall /Customer Send- 1. Customer door closes. 2. Pressure turbine runs for a preset amount of time. 3. Teller Door opens.
System On/Off- 1. On- Activates the system for normal operation. 2. Off- de-activates the system and enables the anti-condensation
feature.
17
DATE
REV.
NAM
E
CO
NTRACT :CH
AN
GES
DRAW
ING
REVIS
ION
Docu
ment
realize
d w
ith v
ers
ion:
0
Use
r data
2
Use
r data
1
07
0Budgie
10/1
6/2
015
DO
OR
MO
TO
R A
SSEM
BLY
SOLIDWORKS Electrical
2016.0.3.12
32
J61
45
6
S3
S4
S5
MM
3 DO
OR M
OTO
RC1
DO
OR C
LO
SED
LIM
IT S
WIT
CH
DO
OR O
PEN
LIM
IT S
WIT
CH
LIM
IT S
WIT
CH
DO
OR S
AFETY
18
REVIS
ION
LO
CATIO
N:
Docu
ment
realiz
ed w
ith v
ers
ion :
CO
NTR
ACT:
SCH
EM
E
SCALE
/
CH
AN
GES
NAM
EREV.
DATE
08
L1
CU
STO
MER U
NIT
CU
STO
MER M
AIN
BO
X
0
2016.0.3.12
11
Use
r data
1U
ser
data
2
011/6
/2015
Budgie
SOLIDWORKS Electrical2
X1
3X1
4X1
K4
2
6 8
4
K5
2
6 8
4
F5
MD
A 2
0 A
MP
F6
MD
A 2
0 A
MP
F7
MD
A 1
1/2
AM
P
F8
MD
A 1
0 A
MP
P2
NL -V
+V
M
M4
MTR
VAC
M
M5
MTR
PRESS
1J8
2
AUD
IO M
UTE C
ON
NECTO
R
E3
01
01
6 5 4 3 2 J3178
HEATER O
UTLET
E1 A
UD
IO O
UTLET
6 5 4 3 2 J41
DO
OR M
OTO
R R
ELA
Y
J5123
DOOR MOTOR CONNECTORCUSTOMER SEND CONNECTOR
FIELD WIRING CONNECTOR
6 8
08-6
2 4
08-6
6 8
08-6
2 4
08-6
NEM
A 5
-20P
PO
WER C
ORD
K3
19
DATE
REV.
NAM
ECH
AN
GES
REVIS
ION
LO
CA
TIO
N:
SCH
EM
E
FO
RTIS
SECU
RIT
Y P
RO
DU
CTS
09
L1
CU
STO
MER
UN
IT
MAN
UAL T
ELLER S
CH
EM
ATIC
0
Use
r data
2
0Budgie
11/1
0/2
015
LN
NI1
I2I3
I4I5
I6I7
I8
24V
50/6
0 H
Z
Q4
Q2
Q3
Q1
1 2
1 2
1 2
1 2
EASY 5
12
S6 S7
H1
H2
K1
+V
VAC R
ELAY
PRESS R
ELAY
CU
ST S
EN
D
SAFETY
DR R
ELAY
-V
1
J2
2
1
J1
2345678
FIE
LD
CABLE
SYSTEM
ON
RECALL
DO
OR C
LO
SED
SW
ITCH
WH
EN
USED
WIT
H 5
000RT C
USTO
MER U
NIT
TH
E
CO
NTR
OL C
ABLE C
HAN
GES T
O A
8 C
ON
DU
CTO
R
20
DATE
REV.
NAM
E
CO
NTRACT :CH
AN
GES
DRAW
ING
REVIS
ION
Docu
ment
realize
d w
ith v
ers
ion:
0
Use
r data
2
Use
r data
1
10
0Budgie
10/1
6/2
015
FR
ON
T P
AN
EL A
SSEM
BLY
SOLIDWORKS Electrical
2016.0.3.12
S1 S2
S8 S9
MIC
RO
PH
ON
E
SPEAKER
CALL B
UTTO
N
CALL B
UTTO
N
SEN
D B
UTTO
N
SEN
D B
UTTO
N
J51
32
TO
AU
DIO
LAN
E S
TATIO
N
TERM
INAL B
LO
CK
21
Care and Maintenance New Installation Fortis Security Products recommends leaving any protective film on the unit during installation to protect finished surfaces. In the case of new construction, adding protective coverings while construction is underway is advised. Dust, fine debris, and chemicals used to clean concrete and masonry, can be harmful to the finish and interfere with equipment functionality. Once installation, construction, and project cleanup are complete:
• Remove all surface dirt and dust using a soft cloth • General purpose surface cleaners can then be used on all Painted
surfaces. Stainless Steel surfaces should only be cleaned using a Stainless Steel cleaner such as “3M Stainless Steel Cleaner”.
• Never use a hose or pressure washer to clean the equipment!
Annual Maintenance Fortis Security Products recommends cleaning and inspecting the equipment as required. Minor scratches can be fixed by cleaning the surface and using enamel based paint. Stainless Steel blemishes can be repaired using a Stainless Steel Cleaner.
Additional Care maybe required if equipment is installed in harsh conditions such as; coastal regions (high salt), dust, industrial pollution.
22
Lane Station Installation
AV-1520 Lane Station The 6000 RT is designed to have audio and video communications from customer unit run through the AV-1520 Lane Station. The microphones, call buttons, and speaker are hard wired within the 6000 RT and are to be connected to a lane station module. The module is mounted on two studs located on the back of the lower service panel. The module’s power supply is plugged into the front outlet located on the top of the electrical box. The microphone wires (shielded cable): Positive (red) negative (black) and common (bare) The speaker wires (red and black wires): Positive (red) and negative (black) The call button wires (blue and white): Signal (blue) and common (white)
Microphone Red +
Microphone Black -
Speaker Red +
Microphone Bare
Call Button Black
Call Button Red
Speaker Black -
Power Connection
Teller Hub Connection
1 and 2 way Video Connection
23
CONNECT CAT 5 TO VIDEO MODULEPORT ON LANE STATION
B
DETAIL BSCALE1 : 4
CAMERA BRACKET
LOOSEN THE TWO TOP RETAINING NUTS FOR THE UPPER DOOR GUIDE CHANNEL. AFTER LOOSENING SLIDE BRACKET UNDER NUTS AND TIGHTEN THEN SLIDE CAMERA IN FROM THE SIDE AND INSTALL MOUNTING SCREWS IN LOWER TWO CAMERA MOUNTING HOLES.
CAMERA INSTALLATION
THE CAMERA BRACKET WILL SLIDEUNDERNEATH THE TWO RETAINING NUTSAS SHOWN
24
34
32
33
35
9
10
CUSTOMER EXTERIOR PARTS LISTBOM Table
9 fs13-0021 UPPER FRONT PANEL 1
10 fs13-0022 LOWER FRONT PANEL 1
32 SR-0115 6000RT CUSTOMER CALL SWITCH 2
33 SR-0114 6000RT CUSTOMER SEND SWITCH 2
34 AV-0008 2.5" MYLAR SPEAKER 1
35 LC-0048,0049,0050 LOCK ASSY. ORDER ALL (3) PARTS 1
25
8
5
11
7
18
18
18
DOOR MOTOR ASSEMBLY PARTS LISTITEM NO. PART NUMBER DESCRIPTION QTY.
5 CUSTOMER DOOR 16 FS13-0506 MOTOR MOUNT PLATE 17 MT-002 DOOR MOTOR 1
8 FS30-0509 LINKAGE ARM WELD VIEW 1
10 FS13-0507 DOOR MOTOR LIMIT SWITCH BRACKET 1
11 MT-005 MOTOR RUN CAPACITOR 1
18 SR-0113 LIMIT SWITCH 3
26
9 13 12
6732811
10
CUS
TOM
ER U
NIT
ELEC
TRIC
AL
BOX
ITEM
NO
.PA
RT N
UMBE
RD
ESC
RIPT
ION
Def
ault/
QTY
.2
amp7
7006
6M
UTE
CO
NN
ECTIO
N1
3am
p770
071
CUS
TOM
ER S
END
CO
NN
ECTO
R1
6am
p770
093
FIEL
D W
IRIN
G C
ON
NEC
TOR
1
7am
p-77
0087
-1D
OO
R M
OTO
R A
SSEM
BLY
CO
NN
ECTO
R1
8SR
-002
6FU
SE H
OLD
ER4
9SR
-011
160
00RT
TUR
BIN
E RE
LAY
210
SR-0
112
6000
RT D
OO
R RE
LAY
111
SR-0
029
PAN
EL O
UTLE
T2
12M
T-02
260
00RT
PO
WER
SUP
PLY
1
13C
N-0
23M
AIN
PO
WER
TER
MIN
AL
BLO
CK
1
27
A ASE
CTIO
N A
-A
3 3
6
8 2 1 9754 454 4
19 7
17
TURB
INE
ASS
EMBL
Y
ITEM
NO
.PA
RT N
UMBE
RD
ESC
RIPT
ION
Def
ault/
QTY
.
1fs
13-0
522
TURB
INE
CEN
TER
HOUS
ING
12
FS13
-052
3TU
RBIN
E M
OTO
R HO
USIN
G2
3M
T-00
1V
AC
UUM
MO
TOR
24
FS13
-053
0TU
RBIN
E M
OTO
R SE
AL
45
FS13
-052
9TU
RBIN
E M
OTO
R M
OUN
TING
PLA
TE2
6FS
13-0
524
TURB
INE
MA
NIF
OLD
WEL
DM
ENT
17
FS13
-053
8TU
RBIN
E TO
P A
ND
BO
TTO
M S
EAL
28
FS13
-052
1TU
RBIN
E TO
P HO
USIN
G C
OV
ER1
9FS
13-0
520
TURB
INE
BOTT
OM
PLA
TE1
17FS
13-0
554
TURB
INE
VA
LVE
ROD
1
19FS
13-0
029
6000
RT T
URBI
NE
AN
D C
USTO
MER
C
HEC
K V
ALV
E1
28
ITEM
NO
.PA
RT N
UMBE
RD
ESC
RIPT
ION
QTY
.3
FS13
-001
1TE
LLER
EXT
ENSI
ON
TUB
E W
ELD
MEN
T2
4FS
13-0
028
MA
NUA
L TE
LLER
LA
ND
ING
PA
D/C
HEC
K V
ALV
E1
6FS
13-0
037
DO
OR
POSI
TION
SW
ITCH
ASS
EMBL
Y1
7FS
13-0
035
TERM
INA
L TO
P A
DA
PTER
TUB
E1
8FS
13-0
039
TELL
ER L
AN
DIN
G P
LATE
19
FS13
-004
2M
AN
UAL
TELL
ER V
ENT
TUBE
110
FS13
-004
7LO
WER
DO
OR
FRIC
TION
RIN
G1
11FS
13-0
048
UPPE
R D
OO
R FR
ICTIO
N S
PAC
ER1
12FS
13-0
050
EXTR
UDED
DO
OR
BAC
KUP
PAN
EL1
13FS
13-0
051
AIR
CHA
MBE
R G
ASK
ET1
14FS
13-0
072
AIR
CHA
MBE
R1
15FS
13-0
073
TELL
ER B
OTT
OM
HO
USIN
G1
16FS
13-0
090
MID
DEL
HO
USIN
G S
LEEV
E1
17FS
13-0
092
EXTR
UDED
DO
OR
BAC
KUP
SEA
L2
18FS
13-0
093
BOTT
OM
PLA
TE G
ASK
ET1
19FS
13-0
094
TELL
ER E
XTEN
SIO
N T
UBE
FLA
NG
E1
20FS
13-0
095
MA
NUA
L TE
LLER
DO
OR
SUB
ASS
EMBL
Y1
21FS
13-0
096
VER
TICA
L D
OO
R SE
AL-
LON
G2
22FS
13-0
097
VER
TICA
L D
OO
R SE
AL
SHO
RT -
TOP-
BOTT
OM
4
39TH
REA
DED
RO
D1/
4-20
THR
EAD
RO
D Z
INC
15"
LO
NG
339
9067
5A02
91/
4-20
HEX
NUT
WITH
LO
CK
WA
SHER
739
9177
2A20
6S.
S. P
AN
HEA
D P
HILI
PS 8
-32
X 2
1/4
LON
G2
3991
772A
213
S.S.
PA
N H
EAD
PHI
LIPS
8-3
2 X
3 1/
2" L
ON
G1
39M
SHXN
UT 0
.138
-32-
S-N
6-32
NYL
OC
K N
UT2
39C
R-TH
MS
0.16
4-32
x0.6
25x0
.625
-NS.
S. P
HILI
PS T
HMS
8-32
X 5
/8" L
ON
G1
39C
R-FH
MS
0.16
4-32
x0.3
75x0
.375
-NS.
S. F
HMS
8-32
X 3
/8" L
ON
G1
51FS
13-0
040
1
30
34
1110
12 8
7
5
69
ITEM
NO
.PA
RT N
UMBE
RD
ESC
RIPT
ION
QTY
.3
FS13
-008
2RE
AR
HOUS
ING
14
FS13
-008
1M
IDD
LE H
OUS
ING
SLE
EVE
15
FS13
-008
0FR
ON
T HO
USIN
G1
6FS
13-0
041
17
SR-0
081
MA
NUA
L TE
LLER
REC
ALL
SW
ITCH
18
SR-0
080
SYST
EM O
N-O
FF S
WITC
H1
9SR
-011
0EA
TON
24
VD
C C
ON
TRO
L M
OD
ULE
1
10C
R-TH
MS
0.16
4-32
x0.3
75x0
.375
-NPH
ILIP
S TH
MS
8-32
X 3
/8" Z
INC
4
1192
185A
213
SHC
S 8-
32 X
2 1
/2" L
ON
G Z
INC
2
1292
185A
203
SHC
S 8-
32 X
1 1
/2" L
ON
G Z
INC
WITH
ST
AR
WA
SHER
4
31
8
9
57
6
ITEM
NO
.PA
RT N
UMBE
RD
ESC
RIPT
ION
QTY
.
5FS
13-0
071
MA
NUA
L TE
LLER
DO
OR
TOP
AN
D B
OTT
OM
26
FS13
-007
7M
AN
UAL
TELL
ER C
ENTE
R D
OO
R SE
CTIO
N1
7FS
13-0
098
MA
NUA
L TE
LLER
DO
OR
FELT
SEA
L TO
P A
ND
BO
TTO
M2
8HD
W-0
110
MA
NUA
L TE
LLER
DO
OR
POSI
TION
MA
GN
ET1
990
385A
199
#8
PHIL
IPS
PAN
HEA
D T
HREA
D F
ORM
ING
SC
REW
FO
R PL
AST
IC8
10FS
13-0
047
LOW
ER D
OO
R FR
ICTIO
N R
ING
111
FS13
-004
8UP
PER
DO
OR
FRIC
TION
SPA
CER
1
32