28
R220 - Location of main parts

4 - Board location

  • Upload
    4k-sdca

  • View
    213

  • Download
    0

Embed Size (px)

DESCRIPTION

R220 - Location of main parts •Boards •Connections and Locations Power Block Interface & Signal Processing Peripheral FAN Sensors and Switches •FPGA Update Physical Location of Boards • Peripheral CN-2926 CT-246 DST-30 PC-105 PS-728 LED-464 FIS-5 TM-50 • CPU SY-345 • Signal Processing MX-113 PR-300 (x2) LPD-2 • Interface HIF-44 DIF-174 IPM-105 Noise Filter for Three Phase Power Noise Filter for Single Phase Power Input Terminal for Three Phase Power AC Inlet for Single Phase Power

Citation preview

Page 1: 4 - Board location

R220 - Location of main parts

Page 2: 4 - Board location

Physical Location of Boards

• Boards• Connections and Locations

Power BlockInterface & Signal ProcessingPeripheralFANSensors and Switches

• FPGA Update

Page 3: 4 - Board location

Boards• Interface

HIF-44DIF-174IPM-105

• CPUSY-345

• Signal ProcessingMX-113PR-300 (x2)LPD-2

• PeripheralCN-2926 CT-246DST-30PC-105PS-728LED-464FIS-5TM-50

Page 4: 4 - Board location

Power Block1

AC Inlet for Single Phase Power

Input Terminal for Three Phase Power

Noise Filter for Three Phase Power Noise Filter for Single Phase Power

Page 5: 4 - Board location

Power Block2

Power Line (Single & Three Phase)

Power Switch

Power SwitchFor Single Phase Power

Power SwitchFor Three Phase Power

Page 6: 4 - Board location

Power Block3

Input to Power Supply(Three Phase)

Single Phase Power Line

Input to Power Supply(Single Phase)

Page 7: 4 - Board location

Power Block4Power Output1(To DST Board)

Power Output2(To SY Board)

Power Output3(To CN Board)

Power Output4(To CT Board)

Page 8: 4 - Board location

Power Block5

Power Supply – Igniter Connections

Igniter – Lamp Connections

Power Supplyfor Igniter

Page 9: 4 - Board location

Interface & Signal Processing1

Interface Boards SY-345 Board

MX-113 Board

PR-300 Board x2

LPD-2 Board

Page 10: 4 - Board location

Peripheral1CN-2926 Board

Shield Case

CN-2926SY-345

Page 11: 4 - Board location

Peripheral2

CT-246 Board

Fan Control (Around Panel)Peltier ControlError Detection

Page 12: 4 - Board location

Peripheral3

DST-30 Board

Fan Control (around Lamp)Error Detection

Page 13: 4 - Board location

Peripheral4PC-105 BoardConnectionCT246 Panel

Panel Red

Panel Green

Panel Blue

CT-246

Shift Block

PS-728 BoardPhoto Sensor(Detecting Red leak light)

Page 14: 4 - Board location

Peripheral5LED-464 BoardStatus LED

Status Message Window

Page 15: 4 - Board location

Peripheral6FIS Board

Interface for Security Control System

Page 16: 4 - Board location

FAN1

Lamp FAN x4

Lamp House

Shield Case

Page 17: 4 - Board location

FAN2

PScon FAN

Shield Case

Page 18: 4 - Board location

FAN3

Board FAN x2

Shield Case

Page 19: 4 - Board location

FAN4

Peltier B FAN

Peltier R FAN

Peltier G FAN

PBS FAN 1 / PBS FAN 2

Opt. Unit FAN

Page 20: 4 - Board location

FAN5

1F FAN Not Connected at Shipment!

Page 21: 4 - Board location

FAN6Main Power Supply

FANs of Power Supply

Lamp Power Supply

Page 22: 4 - Board location

Sensor & Switch1

Lamp ThermostatLamp Thermister

Thermal sensor1Thermal sensor1

1F Thermister

Page 23: 4 - Board location

Sensor & Switch2

2F Thermister

Thermal sensor2Thermal sensor2

Air outside Thermister

Page 24: 4 - Board location

Sensor & Switch3

Mid2F Thermister

Thermal sensor3Thermal sensor3

Opt. Unit Thermister

Page 25: 4 - Board location

Sensor & Switch4Thermal sensor4Thermal sensor4

Panel R/G/B Thermister

Panel

Heat SinkPeltier

Thermister

Page 26: 4 - Board location

Sensor & Switch5

U4 Door Switch

Switch (Open / Close Detector)Switch (Open / Close Detector)

Cold Mirror Switch

Lamp House Switch Filter Cover Switch

Page 27: 4 - Board location

Security Switch

Page 28: 4 - Board location

FPGA Update• Firmware Updater + RS-232C (Network)

PR-300HIF-44DIF-174

• Download Tool + Byteblaster MVMX-113LPD-2

Via CN-2926

Target Board Selection Switch

Byteblaster MV