2
3M CNG Tanks are designed to provide improved capacity and reduced weight in the compressed natural gas vehicle fuel system. 3M CNG Tanks are Type IV tanks featuring 3M Matrix Resin, an exclusive, enhanced epoxy resin that provides improved strength and durability over conventional Type IV CNG Tanks. The tanks are designed for a service pressure of 3600 psi (at 70°F) for applications ranging from automobiles to light, medium and heavy duty trucks and buses. All tanks meet the requirements of ANSI NGV 2-2007 and US DOT MVSS 304 standards. Note: Technical information and data should be considered representative or typical only and should not be used for specification purposes. Dimensions, capacities and weights are nominal, based on design, and may vary slightly due to manufacturing processes. Part Number Diameter at service pressure Length at service pressure Water Volume CNG Capacity GGE** Equivalent DGE** Equivalent Tank Weight Total Tank & Fuel Wt* Mount in in in 3 (L) ft 3 US Gallon US Gallon lb lb 21 x 60L 21.5 60 17,007 (279) 9.8 23.5 21 131 236 Strap 3M CNG Tanks TECHNICAL DATA SHEET FEBRUARY 2013 *Total Tank & Fuel Weight includes tank, valve, PRD, plug and CNG. CNG fuel weight estimate calculated at 70°F and 3600 psig. **GGE and DGE Conversions 0.0844 GGE/L of water volume; 0.0753 DGE/L of water volume.

3M CNG Tanksmultimedia.3m.com/mws/media/878062O/3mtm-cng-tanks... · 3M™ CNG Tanks are designed to provide improved capacity and reduced weight in the compressed natural gas vehicle

  • Upload
    donhu

  • View
    214

  • Download
    2

Embed Size (px)

Citation preview

Page 1: 3M CNG Tanksmultimedia.3m.com/mws/media/878062O/3mtm-cng-tanks... · 3M™ CNG Tanks are designed to provide improved capacity and reduced weight in the compressed natural gas vehicle

3M™ CNG Tanks are designed to provide improved capacity and reduced weight in the compressed

natural gas vehicle fuel system. 3M™ CNG Tanks are Type IV tanks featuring 3M™ Matrix Resin,

an exclusive, enhanced epoxy resin that provides improved strength and durability over

conventional Type IV CNG Tanks. The tanks are designed for a service

pressure of 3600 psi (at 70°F) for

applications ranging from automobiles

to light, medium and heavy duty trucks

and buses. All tanks meet the

requirements of ANSI NGV 2-2007 and

US DOT MVSS 304 standards.

Note: Technical information and data should be considered representative or typical only and should not be used for specifi cation purposes. Dimensions, capacities and weights are nominal, based on design, and may vary slightly due to manufacturing processes.

Part Number

Diameterat service pressure

Lengthat service pressure

Water Volume

CNG Capacity

GGE** Equivalent

DGE** Equivalent

Tank Weight

Total Tank & Fuel Wt* Mount

in in in3 (L) ft3 US Gallon US Gallon lb lb

21 x 60L 21.5 60 17,007 (279) 9.8 23.5 21 131 236 Strap

3M™ CNG TanksTECHNICAL DATA SHEET

FEBRUARY 2013

* Total Tank & Fuel Weight includes tank, valve, PRD, plug and CNG. CNG fuel weight estimate calculated at 70°F and 3600 psig.

**GGE and DGE Conversions 0.0844 GGE/L of water volume; 0.0753 DGE/L of water volume.

Page 2: 3M CNG Tanksmultimedia.3m.com/mws/media/878062O/3mtm-cng-tanks... · 3M™ CNG Tanks are designed to provide improved capacity and reduced weight in the compressed natural gas vehicle

3M™ CNG Tanks

3M is a trademark of 3M Company. Please recycle. Printed in USA.© 2013, 3M. All rights reserved.

Industrial Adhesives and Tapes DivisionBuilding 225-3S-06St. Paul, MN 55144-10001-800-364-3577www.3M.com/cng

Technical InformationThe technical information, recommendations and other statements contained in this document are based upon tests or experience that 3M believes are reliable, but the accuracy or completeness of such information is not guaranteed.

Product Use All statements, technical information and recommendations contained in this document are based upon tests or experience that 3M believes are reliable. However, many factors beyond 3M’s control can affect the use and performance of a 3M product in a particular application, including the conditions under which the product is used and the time and environmental conditions in which the product is expected to perform. Since these factors are uniquely within the user’s knowledge and control, it is essential that the user evaluate the 3M product to determine whether it is fi t for a particular purpose and suitable for the user’s method of application.

Warranty and Limited Remedy Unless stated otherwise in 3M’s product literature, packaging inserts or product packaging for 3M products 3M warrants that each 3M product meets the applicable specifi cations at the time 3M ships the product. Individual products may have additional or different warranties as stated on product literature, package inserts or product packages. 3M MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OF TRADE. User is responsible for determining whether the 3M product is fi t for a particular purpose and suitable for user’s application. If the 3M product is defective within the warranty period, your exclusive remedy and 3M’s and seller’s sole obligation will be, at 3M’s option, to replace the product or refund the purchase price.

Limitation of Liability Except where prohibited by law, 3M and seller will not be liable for any loss or damage arising from the 3M product, whether direct, indirect,special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability.

All tanks come with an installed OMB Lyra CV valve • Cylinder thread connection: 1-1/8 UNF

• Inlet/outlet thread connection: 9/16 UNF

• Integrated Thermally activated pressure relief device

• Electric and manual shut off options

Brackets are available from 3M• Brackets are specially designed to safely and securely fasten the

3M™ CNG Tank to the vehicle while optimizing available space

• Using only the brackets specifi cally designed for 3M™ CNG Tanks ensures

that the tank is allowed to appropriately expand and contract during fi lling

and use