Relays/Timers
e27-1
Relays & TimersSection 27
w w w . a u t o m a t i o n d i r e c t . c o m / r e l a y sVolume 14
In this interactive PDFyou can:
Use bookmarks tonavigate by productcategory
Use bookmarks tosave, search, printor e-mail the catalogsection
Click on part #sto link directly toour online store forcurrent pricing, specs,stocking informationand more
Plug-in OctalCube Relays
75 Series
750/755 series cube relayswith standard octal basedesign, offer high-currentcapability (12A) withcompact design. Available in24 VAC, 120 VAC, 240 VACand 24 VDC coil voltages.
Open-StylePower Relays
AD Series
AD-PR40 series power relaysare open construction designwith high power contactscapable of switching up to40A. SPDT, DPST and DPDTmodels are available.
Plug-in HazardousLocation Octal andSquare/Cube Relays
H782/H750 Series
H782/H750 series hermeti-cally sealed, ice cube stylerelays are designed for appli-cations requiring hermeti-cally sealed units forhazardous factory locations.(Class I, Div. 2 Groups A, B,C, D).
Latching OctalCube Relay
755 Series
755 series cube relays, witha 16A contact rating, areideal for applicationsrequiring a latching device.Permanent magnet main-tains last position. Availablein 120 VAC and 24 VDCcoil voltages.
Electromechanical Square/Cube Relays
QL Series: General purpose relays designed for a widerange of applications. Units plug into DIN-rail mountable relaysockets, with a 10A contact rating. Ideal for electric controlpanels requiring stable and reliable relays.
QM Series: General purpose relays with a 5A DPDTor 3A 4PDT contact rating, designed for use in applicationsfrom power to sequence controls in various factory machinesand control panels.
78 Series: 78 series cube relays, with a 15A contact rating,are ideal for applications demanding high power control invarious factory machines and control panels. Available in 24VAC, 120 VAC, 240 VAC and 24 VDC coil voltages.
Our general purpose industrial relays are a low-cost way ofadding control and isolation relays to any application.Electromechanical relays are available in cube, open andcard styles for a diverse range of installation requirements.Cube relays are available with standard linear or octal baseconnection patterns. Solid state relays available includehazardouse location, socket-mount, DIN-rail mount andpanel-mount styles.
All relays feature LED indicators for easy troubleshooting.
A Full Lineupof Control Relays
E l e c t r o m e c h a n i c a l
Relays and Timerse27-2 1 - 8 0 0 - 6 3 3 - 0 4 0 5Volume 14
Panel Mount HockeyPuck Relays
AD-SSR5 Series
Socket Mount Relays
AD-70S2 Series
These solid state relays, with4A contact ratings, plug intoa DIN-rail mountable relaysocket or can be wired withthe quick-connect terminals.
DIN Rail Mount Relays
AD-SSR/AD-HSSR Series
Low price combined with industry-demanded qualitymake our relays one of the best values in automation.
Our manufacturers ensure that nothing is spared inthe design and production of our products. Byoffering them direct to you, AUTOMATIONDIRECTmakes certain that you get the same or better qualitythan other brands at a great price.
Check the technicalspecifications on thefollowing pages to
choose the right relayfor your application.
Two-year warranty
Integral heat sink
Finger safe cover
Red LEDstatus lamp
Mechanicalstatus flag forcontact closure
Mechanicalpush to test
Socketcompatibility
Small size
Slim/Card Relay
RS Series
Solid State Relays
Electromechanical Relays
RS series relays arecompact, space-saving,relay terminal modulescontaining four or six relayswith one N.O. contact each.
These relay-and-terminalmodules are ideal for inter-facing electronic controldevices with output devices.
LED for input coil
Quality built into every relayat an affordable price.
Lock-down doorfor circuit testing
78 Series
IdentificationLabel
S o l i d S t a t e
AD-SSR2 Series - AC and DC input,AC output with 10 or 25 Amp loads
AD-SSR8 Series - Class 8 solid state relayswith energy efficient current switching ina slim, space-saving housing
AD-HSSR8 Series - hazardous location solidstate relays (HAZLOC relays)
DIN Rail Mount Relays
AD-SSR/AD-HSSR Series
AD-SSR6 series Class 6 solidstate relays have electro-mechanical relays with solid-state circuitry and high loadratings up to 75 amps in afinger-safe "Hockey Puck"housing.
Class 8 hazardous locationseries in a slim, space-savinghousing (8A, 10A, 15A) withthe added feature of beingapproved for hazardouslocations (Class 1, Div. 2,Groups A, B, C, D).
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-3
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more &other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
MotorControls
ProximitySensors
PhotoSensors
LimitSwitches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks &Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-4Volume 14
Electromechanical Relay Selection Guide
QL Series Electromechanical Relay Selection Guide
Specification QL Series QM Series RS Series Card RelaysCoil Voltages 110/120VAC, 220VAC, 24VDC 110/120VAC, 220VAC, 24VDC 24VDC
Configuration 2PDT, 4PDT 2PDT, 4PDT SPST (up to six relays)
Contact Rating 10A 5A DPDT ; 3A 4PDT 5A
Base Socket 8 or 14 pin spade terminal 8 or 14 pin spade terminal -Agency Approvals UL Recognized (#E222847), CE Certified(9667186-9811), CSA Certified (218218)
UL Recognized (#E222847), CE Certified(9667186-9811), CSA Certified (218218)
UL Recognized (E44592), CSA (LR20479) TUV(R95551729)
Prices starting at
QL Series Selection Guide
Part Number Price Coil Voltage Configuration Contact RatingDimensions(see page24-7)
Relay SocketPart Number Price
Dimensions(see page24-13)
QL2N1-A120 110/120VAC
2PDT 10A Figure 1 SQL08D Figure 3
QL4N1-A120 4PDT 10A Figure 2 SQL14D Figure 4
QL2N1-A220 220VAC
2PDT 10A Figure 1 SQL08D Figure 3
QL4N1-A220 4PDT 10A Figure 2 SQL14D Figure 4
QL2N1-D24
24VDC
2PDT 10A Figure 1 SQL08D Figure 3
QL2X1-D24 2PDT 10A Figure 1 SQL08D Figure 3
QL4N1-D24 4PDT 10A Figure 2 SQL14D Figure 4
QL4X1-D24 4PDT 10A Figure 2 SQL14D Figure 4
Features Small package design ARC Barrier equipped Silver CadmiumOxide contact High dielectric strength (1,800 VAC) High reliability and long life Ultra-high sensitivity with quickresponse time (25msmax.)
High vibration and shock resistance
LED indicator on all models, so you caneasily see if relay is working properlywithout using a voltmeter
Diode protection available on 24 VDCmodels, which protects contacts andelectronic components from back EMF
UL recognized, CE certified, CSAapproval pending
DPDT and 4PDTmodels
QL series relays are general purpose relays designed for a wide range of applications,from power to sequence controls in various factory machines and control panels. Theyare ideal for electric control panels requiring stable and reliable relays.
ORDER SOCKET SEPARATELY
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-5
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more &other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
MotorControls
ProximitySensors
PhotoSensors
LimitSwitches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks &Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
QL Series Electromechanical Relay Specifications
QL Series Specification Table
Part Numbers
QL2N1-A120
QL2N1-A220
QL4N1-A120
QL4N1-A220
QL2N1-D24
QL2X1-D24
QL4N1-D24
QL4X1-D24
Contact Specifications
Current Rating 10A
Contact Type DPDT 4PDT DPDT 4PDT
Terminal Type Spade Plug-In Socket
Rated Max. Resistive Load 10A@110VAC/10A@24VDC
Rated Max. Inductive Load 7.5A@110VAC/ 5A@24VDC
Minimum Recommended Load 1mA @ 5VDC
Max. Switching Cap. (Resistive Load) 1,100VAC/240W
Max. Switching Cap. (Inductive Load) 825VAC/120W
Max. Contact Rating 250VAC/125VDC
Coil Specifications
Options LED IndicatorLED
Indicator/DiodeProtection
LED IndicatorLED
Indicator/DiodeProtection
Coil Input Voltage 110/120VAC 220/240VAC 110/120VAC 220/240VAC 24VDC
Rated Current at 50Hz 9.9 /10.8mA 6.2/6.8mA 17/19mA 11.5/13.1mA 36.9mA 69mA
Rated Current at 60Hz 8.4/9.2mA 5.3/5.8mA 18/16.4mA 9.8/11.2mA 36.9mA 69mA
Coil Resistance 4.43k 12.95k 2.2k 6.7k 650 350
Power Consumption Approx. 0.9W to 1.1W (at 60Hz) Approx. 0.9W
Dropout Voltage(% of rated voltage) Min. 30% Min. 10%
Pick-Up Voltage(Must operate voltage) Max. 80% of the rated coil voltage
Max. Voltage(Max. continuous voltage) 110% of the rated coil voltage
Min. Operating Voltage 80% of the rated coil voltage
General Specifications
Service LifeMechanical: AC: Min. 50 million operations; DC: Min. 100 million operations (at operating frequency of 18,000 operations/hour)
Electrical: DPDT: Min. 500k operations; 4PDT: Min. 200k operations (at operating frequency of 1,800 operations/hour)
Operate Time 25ms max
Release Time 25ms max
Ambient Temperature -25 C to 70 C (-13 F to 158 F)
Ambient Humidity 45% to 85% Relative Humidity
Contact Material Silver Cadmium Oxide
Contact Resistance 50mmax.
Operating Frequency Mechanical 18,000 operations/hour; Electrical 1,800 operations/hour
Vibration Resistance 10Hz to 55Hz at double amplitude of 1.0mm
Shock Resistance 1,000m/s2 (approx. 100G)
Weight 35g (1.24oz.)
Agency Approvals and Standards UL Recognized (#E222847), CE Certified (9667186-9811), CSA Certified (218218)
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-6Volume 14
QL Series Wiring Diagrams and Derating CurvesWiring Diagrams
4PDT
7 8
1
3
5
24
6
QL2N1-A120QL2N1-A220
7 8
1
3
5
24
6(-) (+)
QL2N1-D24 QL2X1-D24
13
1
5
9
2
6
10
3
7
11
4
8
12
1413
1
5
9
2
6
10
3
7
11
4
8
12
14(-) (+)13
1
5
9
2
6
10
3
7
11
4
8
12
14(-) (+)
QL4X1-D24QL4N1-D24QL4N1-A120QL4N1-A220
Max. Switching capacity
Rated
oper
atin
gcu
rren
t(A)
10
5
1
0.5
0.1
5 10 50 100 500Rated operating voltage (V)
AC resistive
AC inductivep.f = 0.4
DC inductiveL/R = 7ms
DC resistive
QL DPDT
Max. Switching capacity
Rated
oper
atin
gcu
rren
t(A)
10
5
1
0.5
0.1
5 10 50 100 500Rated operating voltage (V)
AC resistive
AC inductivep.f = 0.4
DC inductiveL/R = 7ms
DC resistive
QL 4PDT
2PDT
8
1
3
5
2
4
6
7 (-) (+)
Derating Curves
QL 2PDT
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-7
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more &other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
MotorControls
ProximitySensors
PhotoSensors
LimitSwitches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks &Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
QL Series Dimensional Drawings
Max. 36.0 [1.42]
0.5
[0.0
2]5.
0[0
.20]
3.0 [0.12]
6.4 0.25] Max. 21.5[0.85]
5.75
[0.2
3]
Max
.28
.0[1
.10]
14 -3.0 [0.12] 1 2
3 4
5 6
7 8
Dimensionsmm [inches]
Figure 1QL2
14 - 3.0 Dia. holes
6.4[.25]
3.0[0.12]
5.0
[0.2
0]
0.5
[0.0
2]
41.5 [1.63]
Max
.28
.0[1
.10]
1 2 3 4
5 6 7 89 10 11 12
Max.Max. 36.0 [1.42]
Figure 2QL4
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-8Volume 14
QM Series Electromechanical Relay Selection Guide
Features Small package design DPDT has a fine silver contact with 5Acapability
4PDT has a gold-plated silver contact with3A capability
High dielectric strength (1,800 VAC) High reliability and long life Ultra-high sensitivity with quick responsetime (20msmax.)
High vibration and shock resistance
LED indicator on all models, so you caneasily see if relay is working properlywithout using a voltmeter
Diode protection on some 24 VDCmodelsprotects contacts and electroniccomponents from back EMF
UL recognized, CE certified, CSA certified(218218)
QM Series Selection Guide
Part Number Price Coil Voltage Configuration Contact RatingDimensions(see page24-11)
Relay SocketPart Number Price
Dimensions(see page24-13)
QM2N1-A120 110/120VAC
2PDT 5A Figure 1 SQM08D Figure 5
QM4N1-A120 4PDT 3A Figure 2 SQM14D Figure 6
QM2N1-A220 220VAC
2PDT 5A Figure 1 SQM08D Figure 5
QM4N1-A220 4PDT 3A Figure 2 SQM14D Figure 6
QM2N1-D24
24VDC
2PDT 5A Figure 1 SQM08D Figure 5
QM2X1-D24 2PDT 5A Figure 1 SQM08D Figure 5
QM4N1-D24 4PDT 3A Figure 2 SQM14D Figure 6
QM4X1-D24 4PDT 3A Figure 2 SQM14D Figure 6
QM series relays are general purpose relays designed for a wide range of applications,from power to sequence controls in various factory machines and control panels. Theyare ideal for electric control panels requiring stable and reliable relays.
ORDER SOCKET SEPARATELY
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-9
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more &other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
MotorControls
ProximitySensors
PhotoSensors
LimitSwitches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks &Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
QM Series Electromechanical Relay Specifications
QM Series Specification Table
Part Numbers
QM2N1-A120
QM2N1-A220
QM4N1-A120
QM4N1-A220
QM2N1-D24
QM2X1-D24
QM4N1-D24
QM4X1-D24
Contact Specifications
Current Rating 5A 3A 5A 3A
Contact Type DPDT 4PDT DPDT 4PDT
Terminal Type Spade plug-in socket
Rated Max. Resistive Load 5A @ 220VAC/5A @ 24VDC 3A @ 220VAC/3A @ 24VDC 5A @ 220VAC/5A @ 24VDC 3A @ 220VAC/3A @ 24VDC
Rated Max. Inductive Load 2A @ 220VAC/2A @ 24VDC 1.5A @ 220VAC/0.8A @ 24VDC 2A @ 220VAC/2A @ 24VDC 1.5A @ 220VAC/0.8A @ 24VDC
Minimum Recommended Load 1mA @ 1VDC
Max. Switching Cap. (Resistive Load) 1,100VA/120W 660VA/72W 1,100VA/120W 660VA/72W
Max. Switching Cap. (Inductive Load) 440VA/48W 176VA/36W 440VA/48W 176VA/36W
Max. Contact Rating 250VAC/125VDC 250VAC/125VDC
Coil Specifications
Options LED IndicatorLED
Indicator/DiodeProtection
LED IndicatorLED
Indicator/DiodeProtection
Coil Input Voltage 110/120VAC 220/240VAC 110/120VAC 220/240VAC 24VDC
Rated Current at 50Hz 9.9 /10.8mA 6.2/6.8mA 9.9/10.8mA 6.2/6.8mA36.9mA
Rated Current at 60Hz 8.4/ 9.2mA 5.3/5.8mA 8.4/9.2mA 5.3/5.8mA
Coil Resistance 4.43k 12.95k 4.43k 12.95k 650
Power Consumption Approx. 0.9W to 1.1W (at 60Hz) Approx. 0.9W
Dropout Voltage(% of rated voltage) Min. 30% Min. 10%
Pick-Up Voltage(Must operate voltage) Max. 80% of the rated coil voltage
Max. Voltage(Max. continuous voltage) 110% of the rated coil voltage
Min. Operating Voltage 80% of the rated coil voltage
General Specifications
Service LifeMechanical: AC: Min. 50 million operations; DC: Min. 100 million operations (at operating frequency of 18,000 operations/hour)
Electrical: DPDT: Min. 500k operations; 4PDT: Min. 200k operations (at operating frequency of 1,800 operations/hour)
Operate Time 20ms max
Release Time 20ms max
Ambient Temperature -25 C to 75 C (-13 F to 167 F)
Ambient Humidity 45% RH to 85% RH
Contact Material Fine Silver Gold-plated Silver Fine Silver Gold-plated Silver
Contact Resistance 50mmax
Operating Frequency Mechanical: 18,000 operations/hour; Electrical: 1,800 operations/hour
Vibration Resistance 10Hz to 55Hz at double amplitude of 1.0mm
Shock Resistance 1,000m/s2 (approx. 100G)
Weight 35g (1.24oz.)
Agency Approvals and Standards UL Recognized (#E222847), CE Certified (9667186-9811), CSA Certified (218218)
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-10Volume 14
QM Series Wiring Diagrams and Derating Curves
13 14
1
5
9
4
8
12
13-
1
5
9
2
6
10
4
8
12
3
7
11+ 1413 14
1
5
9
2
6
10
4
8
12
3
7
11
Wiring diagrams
Derating curves
QM2N1-A120QM2N1-A220 QM2X1-D24
QM4X1-D24
QM2N1-D24
QM4N1-D24QM4N1-A120QM4N1-A220
13 14
1
5
9
4
8
12+-13- 14
1
5
9
4
8
12
+
13 14
1
5
9
2
6
10
4
8
12
3
7
11- +
Max. Switching capacity
Rated
oper
atin
gcu
rren
t(A)
10
5
1
0.5
0.1
5 10 50 100 500Rated operating voltage (V)
QM DPDT
AC resistive
AC inductivep.f = 0.4
DC inductiveL/R = 7ms
DC resistive
Max. Switching capacity
Rated
oper
atin
gcu
rren
t(A)
10
5
1
0.5
0.1
5 10 50 100 500Rated operating voltage (V)
QM 4PDT
3
AC resistive
AC inductivep.f = 0.4
DC inductiveL/R = 7ms
DC resistive
DPDT 4PDT
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-11
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more &other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
MotorControls
ProximitySensors
PhotoSensors
LimitSwitches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks &Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
QM Series Dimensional Drawings
g g
8 -Dia. 1.2 [0.05] x 3 Holes
2.6
[0.1
0]0.5
[0.0
2]
0.5[0.02]
6.0[0.24]
Max. 36.0 [1.42]
Max. 21.5[0.85]
Max
.28
.0[1
.10]
6.3
[0.25]
0.5[0.02]
Max. [1.42] 0[0.24]
Max. 21.5[0.85]
Max
.28
.0[1
.10]
6.3
[0.25]
0.5
[0.0
2]2.
6[0
.10]
14 - Dia. 1.2 [0.05] x 3 Holes
6.36.0
Figure 1QM2 Series
Figure 2QM4 Series
Dimensionsmm [inches]
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-12Volume 14
Sockets for QL/QM Series Relays
Din-rail mounting,DPDT, for use withQL2 series relays
Din-rail mounting,DPDT, for use withQM2 series relays
Din-rail mounting,4PDT, for use withQM4 series relays
Din-rail mounting,4PDT, for use withQL4 series relays
SQL08D SQL14D
Note: Order sockets separately; holding clips are included with sockets.
SQM08D SQM14D
6.2
[0.24]
4.6 [0.18]
49.9 [1.96]
5.0
[0.20]
10.7[0.42]
10.0[0.39]
7.0
[0.28]
45.5[1.79]
4.5[0.18]
16.0[0.63]
4.5
[0.18]
Holding ClipsHolding clips for the QL2, QL4, QM2 and QM4 series relays can be removed bypushing the side of the inserting hole with a sharp object.
Holding ClipDimensionsmm [in]
Holding clip for QL4series relays is includedwith SQL14D sockets.
Holding ClipDimensionsmm [in]
Holding clip for QL2,QM2 and QM4 seriesrelays is included withSQL08D, SQM08D andSQM14D sockets.
Relay
HoldingClip
Socket
Insert holding clip into the slots providedon the socket.
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-13
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more &other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
MotorControls
ProximitySensors
PhotoSensors
LimitSwitches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks &Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
Socket Dimensions for QL/QM Series Relays
Figure 5SQM08D (for QM2 Series Relays)
3
4 Dia.
3
17.6
72.1 35 29 35.4 75.55
8
20.2
34
6 5
12
34
56
78
Top View
58.1
62.4
71.9
35.5
38.9
7.1 2.9
30
19
4 3 2 1
8 7 6 5
12 11 10 9
14 13
45
6 578
9101112
Top View
Top ViewTop View
29.46
72
7 7 7
24
29.5
2835.5
75.2
30
17.3
3 2 1
8 7 6 5
12 11 10 9
4 14 13
8 7 6 5
12 11 10 9
Figure 3SQL08D (for QL2 Series Relays)
Figure 6SQM14D (for QM4 Series Relays)
Figure 4SQL14D (for QL4 Series Relays)
Dimensionsmm
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-14Volume 14
RS Series Electromechanical RelaySelection Guide
RB105-DE TY3 RZ4N
RS Series Card Relay Selection Guide
Part Number Price Description Dimensions and Wiring Diagrams
RS4N-DE Card relay (4 relays included; 4 commons), mounted in socket, 24VDC coil, SPST,5A rating. TY3 included; (can only be wired one way for proper operation of LEDs) Figure 3
RS6N-DE Card relay (6 relays included; 2 commons; 3 relays per common), mounted insocket, 24VDC coil, SPST, 5A rating. TY3 included. Figure 4
RB105-DE Spare relays (package of 10) for the RS series Relays. 24V DC coil, SPST, 5A rating. Figure 1
TY3 Relay remover for RS series relays. Package of 10. -
RZ4N Terminal guard for RS series relays. Package of 10. Figure 2
RS4N-DE
4 relays
TerminalModule
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-15
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more &other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
MotorControls
ProximitySensors
PhotoSensors
LimitSwitches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks &Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
RS Series Relay Specifications
RS4N-DE and RS6N-DE Series Card Relay Specifications TableContact 1 NO / SPST
Contact Resistance 30m or less (before use)
Contact Material Silver alloy (gold-plated)
Min. Operating Voltage and Current 0.1VDC, 1mA
Rated Thermal Current 5A
Max. Make/Break Current (Resistive Load) 250VAC, 5A30VDC, 5AOperating Time 10ms or less at rated voltage
Release Time 10ms or less at rated voltage
Insulation Resistance 100M (at 500VDC megger)
DielectricStrength
Between Contact and Coil 2000VAC 1 minute
Between Contacts of Same Pole 750VAC 1 minute
Between Contacts of Different Pole 2000VAC 1 minute
Between Coils of Different Pole 500VAC 1 minute
VibrationMalfunction Durability 10 to 55Hz, 1mm double amplitude
Mechanical Durability 10 to 55Hz, 1.5mm double amplitude
ShockMalfunction Durability 100m/s2
Mechanical Durability 1000m/s2
LifeExpectancy
Mechanical 20 million operations
Electrical
Voltage MakeCurrent (A)BreakCurrent (A) Operations
220VAC (inductive load)220VAC (resistive load)24VDC (inductive load)24VDC (resistive load)
2 (cos = 0.7)3 (cos = 1.0)1 (T = 15ms)5 (T = 1ms or less)
2 (cos = 0.3 - 0.4)3 (cos = 1.0)1 (T = 15ms)5 (T = 1ms or less)
100,000130,000150,000100,000
Ambient Temperature -25 to + 55 C (no icing)
RS series relays are compact, space-savingrelay terminal modules containing four orsix card relays with one normally opencontact each. These relay-and-terminalmodules are ideal for interfacingelectronic control devices (such as PLCs orphotoelectric sensors) with output devices.
RS6N-DE
RS4N-DE
Features: Compact size of 34mmwide by 69mmlong, including screw terminals
Input terminals are located in the upperpart and output terminals in the lower partof themodule to separate them from eachother, makingwiring easy
RB105 plug-in relays and TP04 socketsmakemaintenance easy
Built-in coil surge-suppression diodes andoperation indicator LEDs simplify circuitdesign andmaintenance
Themodule is easily-mounted on a 35mmDIN rail
The RS4Nmodule includes two standardaccessory jumper plates, which areconvenient for commonwiring ofterminals
RS6N-DE
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-16Volume 14
Electromechanical Relay RB105-DE Specifications
These spare relays are for replacementin RS4N-DE and RS6N-DE relaymodules (5 mm). Bifurcated contactsensure high contact reliability, allowinguse in low-level circuits.
RB105-DE
FeaturesNarrow, miniature size and lightweight reduces space on the DIN rail
UL, CSA, CE, and TUV approved Low power consumption Can be operatedwith a non-polaritymagnet
Flux-tight construction
RB105-DE
RB105-DE Card Relay Specification TableOperating Time 10ms or less at rated voltage
Release Time 5ms or less at rated voltage
Insulation Resistance 100M (at 500VDC megger)
Dielectric Strength 750VAC 1 minute between open contacts2000VAC 1 minute between contact and coil
Impulse 4,500V or more 1.2 x 50s between contact and coil
Electrical Life Expectancy AC: 100,000 operations at 220VAC 2A, inductive load130,000 operations at 220VAC 3A, resistive loadDC: 150,000 operations at 24VDC 1A, inductive load100,000 operations at 24VDC 5A, resistive load
Mechanical Life Expectancy 20 million operations
Ambient Temperature -40 C to +70 C (no icing)
Thermal Current 5A
Make and Break Current (Resistive Load) 250VAC, 5A30VDC, 5A
Operating Coil
Rated voltage 24VDC
Pick-up voltage 70% of rated coil voltage
Drop-out voltage 5% of rated coil voltage
Power consumption 200mW
Coil resistance 2880
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-17
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more &other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
MotorControls
ProximitySensors
PhotoSensors
LimitSwitches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks &Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
RS Series Relay Remover and Protective Cover
34
69
6.5
(35)13.2
3
RZ4N
To remove a relay from the terminal module,use the TY3 relay remover. RS4N-DE andRS6N-DE modules include a TY3 relayremover. Pull the relay in a direction perpen-dicular to the terminal module surface.Incorrectly removing or mounting a relaymay damage the relay pins and pin jacks ofthe module.
TY3
A protective cover fits over theRS4N-DE or RS6N-DE module andprotects the terminals.
RZ4N
PC board drilling (View from back side)
Internal wiring diagram
5.08 max
21.3 max
20
0.5 0.5
1
0.3
2-0.7
1.3 7.62 7.62 2.54
2-0.5
3.8
ma
x
12.6
max
1.2 Dia.0.1
7.62 7.62 2.54
2.54
2.54
Figure 1 RB105-DE
Figure 2 RZ4N (Terminal guard for RS Series)
Relay remover, TY3 Optional protectivecover, RZ4N
Dimensionsmm
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-18Volume 14
RS Series Relay Dimensions and Wiring Diagrams
43.5 (Rail height 15)
Internal Wiring32
36 (Rail height 7.5)
28.3
6.834
69 85
IN
OUT
Operationindicator
M3.5 x 6.5
DIN 35mm rail
IN
OUT
16
12
15
11
14
10
13
9
Jumper
+-4 3 2 1
8 7 6 5+-
+-
+-
Wiring diagramRS4N-DE
3228.3
6.834
69 85
IN
OUT
Operationindicator
M3.5 x 6.5
43.5 (Rail height 15)36 (Rail height 7.5)
DIN 35mm rail
4 3+ +
2- -
----
1
8 7 6 5
12
16
11
15
10
14
9
13
IN
COM
COM COM
COM
Internal Wiring
OUT
Figure 3 RS4N-DE
Figure 4 RS6N-DE Wiring diagramRS6N-DE
- included only withRS4N-DE
Dimensionsmm
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-19
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more &other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
MotorControls
ProximitySensors
PhotoSensors
LimitSwitches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks &Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
78 Series Electromechanical Relay Selection Guide
These ice cube style relays are powerrelays designed for applicationsdemanding high power control in variousfactory machines and control panels. Theyare ideal for electrical control panelsrequiring stable and reliable relays.
Specification 781 Series 782 Series 783 Series 784 Series
Coil Voltages 110/120VAC, 220VAC, 12VAC, 12VDC,24VAC, 24VDC110/120VAC, 220VAC, 12VAC, 12VDC,24VAC, 24VDC
110/120VAC, 220VAC, 12VAC, 12VDC,24VAC, 24VDC
110/120VAC, 220VAC, 12VAC, 12VDC,24VAC, 24VDC
Configuration SPDT DPDT 3PDT 4PDTContact Rating 12 to 15A 12 to 15A 12 to 15A 12 to 15ABase Socket 5 pin spade terminal 8 pin spade terminal 11 pin spade terminal 14 pin spade terminal
Agency ApprovalsUL Recognized (E191059), CE,IEC Std 947-4-1 and 947-5-1,CSA 244610
UL Recognized (E191059), CE,IEC Std 947-4-1 and 947-5-1,CSA 244610
UL Recognized (E191059), CE,IEC Std 947-4-1 and 947-5-1,CSA 244610
UL Recognized (E191059),CE, CSA 244610
Prices starting at
78 Series Relays Selection GuideNOTE: Not recommended for low current switching. Find contacts Minimum Switching Requirement on following page.
For low current switching, please see the QM4N1 and QM4X1 series.
Part Number Price Coil Voltage Configuration Dimensions Relay SocketPart Number Price Dimensions
781-1C-12D 12VDC
SPDT Figure 1 781-1C-SKT Figure 5
781-1C-12A 12VAC781-1C-24D 24VDC781-1C-24A 24VAC781-1C-120A 120VAC781-1C-240A 240VAC782-2C-12D 12VDC
DPDT Figure 2 782-2C-SKT Figure 6
782-2C-12A 12VAC782-2C-24D 24VDC782-2C-24A 24VAC782-2C-120A 120VAC782-2C-240A 240VAC783-3C-12D 12VDC
3PDT Figure 3 783-3C-SKT Figure 7
783-3C-12A 12VAC783-3C-24D 24VDC783-3C-24A 24VAC783-3C-120A 120VAC783-3C-240A 240VAC784-4C-12D 12VDC
4PDT Figure 4 784-4C-SKT-1 Figure 8
784-4C-12A 12VAC784-4C-24D 24VDC784-4C-24A 24VAC784-4C-120A 120VAC784-4C-240A 240VAC
Features Small package design Silver CadmiumOxide gold flashed contact High open contact dielectric strength(up to 2500V rms)
High reliability and long life High vibration and shock resistance LED indicator on all models, so you caneasily see if the relay is working properlywithout using a voltmeter
Flag indicator shows relay status inmanualor powered condition
A pushbutton allowsmanual operation ofthe relay without the need for power to thecoil
Lock-Down door, when activated, holdspushbutton and contacts in the operateposition, allowing circuits to be analyzed.This feature is not available on 781 series.
SPDT, DPDT, 3PDT and 4PDTmodels Finger grip cover allows easier removal ofrelays from sockets than conventional relays
I.D. tag/write labels for identifying relays inmulti-relay circuits
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-20Volume 14
78 Series Electromechanical Relay Specifications
781 Series Contact Ratings (current)Resistive *Motor Load
Voltage Nominal UL CSA UL28VDC 12A 12A 12A ---120VAC 15A 15A 15A 1/2Hp277VAC 12A 12A 12A 1Hp
782 Series Contact Ratings (current)Resistive *Motor Load
Voltage Nominal UL CSA UL28VDC 12A 12A 12A ---120VAC 15A 15A 15A 1/2Hp277VAC 12A 12A 12A 1Hp
NEMA Mechanical Switching Ratings and Test Values for AC Control Circuit Contacts
Contact RatingDesignation
ThermalContinuous TestCurrent (A)
Maximum AC Current, 50/60Hz (A)Voltamperes
120 Volts 240 Volts 480 Volts 600 VoltsMake Break Make Break Make Break Make Break Make Break
B300 5 30 3.00 15 1.50 --- --- --- --- 3600 360This chart is provided as a guideline only, and the ratings and values are not guaranteed to be accurate. It is the users responsibility to properly size their controlcircuit devices. The chart values are from NEMA Standard ICS 5-2000, Table 1-4-1.
78 Series Relay Specification Table
Part Numbers
781-1C-12D
781-1C-12A
781-1C-24D
781-1C-24A
781-1C-120A
781-1C-240A
782-2C-12D
782-2C-12A
782-2C-24D
782-2C-24A
782-2C-120A
782-2C-240A
General Specifications
*Service Life: Mechanical / Electrical OperationsMechanical: 10,000,000 operations unpowered
Electrical: 100,000 operations @ rated resistive load
Operating Temperature -40C to 55C (-40F to 131F)Response Time 20 msAmbient Humidity 45% RH to 85% RHVibration Resistance 3 Gs, 10 to 55Hz (0.6mm double amplitude)Shock Resistance 10 GsWeight 29 g (1.02 oz) 36 g (1.27 oz)**Agency Approvals and Standards UL Recognized File E191059, CE, CSAEnvironmental Protection IEC IP40NEMA B300 Pilot Duty Rated Yes
Coil SpecificationsStandard LED IndicatorCoil Input Voltage 12VDC 12VAC 24VDC 24VAC 120VAC 240VAC 12VDC 12VAC 24VDC 24VAC 120VAC 240VACCoil Resistance 188 46 750 180 4.43k 15.72k 160 46 650 180 4.43k 15.7k
Power Consumption 0.7W DC,0.9VA @ 60Hz AC @ 25C0.9W DC,
1.2VA@ 60Hz AC @ 25C
Dropout Voltage (% of nominal voltage or more) 10% 15% Min.10% Min. 15% 10% 15% Min. 10% Min. 15%Pull-in Voltage (% of nominal voltage or less) 80% 85% 80% 85% 80% 85% 80% 85%Max. Voltage (Max. continuous voltage) 110% of the rated coil voltage
Contact SpecificationsContact Type SPDT DPDTContact Material Silver cadmium oxide, gold flashedMinimum Switching Requirement 100mA @ 5VDCMax. Contact Rating Refer to Contact Ratings charts.Dielectric Strength Between Contacts 1500V rms
*Note: These devices are rated for 1,000 cycles when used in a motor application. (Per Table 45.1, UL 508).**Note: UL listed when used with sockets 781-1C-SKT, 782-2C-SKT, 783-3C-SKT, 784-4C-SKT, or 784-4C-SKT-1. Current limited to rating of relay or socket, whichever is less.
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-21
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more &other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
MotorControls
ProximitySensors
PhotoSensors
LimitSwitches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks &Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
78 Series Electromechanical Relay Specifications
783 Series Contact Ratings (current)Resistive *Motor Load
Voltage Nominal UL CSA UL28VDC 12A 12A 12A ---120VAC 15A 15A 15A 1/2Hp277VAC 12A 12A 12A 3/4Hp
784 Series Contact Ratings (current)Resistive *Motor Load
Voltage Nominal UL CSA UL28VDC 12A 12A 12A ---120VAC 15A 15A 15A 1/2Hp277VAC 12A 12A 12A 3/4Hp
78 Series Relay Specification Table
Part Numbers
783-3C-12D
783-3C-12A
783-3C-24D
783-3C-24A
783-3C-120A
783-3C-240A
784-4C-12D
784-4C-12A
784-4C-24A
784-4C-24A
784-4C-120A
784-4C-240A
General Specifications
*Service Life: Mechanical / Electrical OperationsMechanical: 10,000,000 operations unpowered200,000 operations @ rated resistive load
Operating Temperature -40C to 55C (-40F to 131F)Response Time 20 msAmbient Humidity 45% RH to 85% RHVibration Resistance 3 Gs, 10 to 55Hz (0.6mm double amplitude)Shock Resistance 10 GsWeight 60 g. (2.12 oz.) 80 g (2.82 oz)**Agency Approvals and Standards UL Recognized File E191059, CE, CSAEnvironmental Protection IEC IP40NEMA B300 Pilot Duty Rated Yes
Coil SpecificationsStandard LED IndicatorCoil Input Voltage 12VDC 12VAC 24VDC 24VAC 120VAC 240VAC 12VDC 12VAC 24VDC 24VAC 120VAC 240VACCoil Resistance 100 25.3 400 103 2.77k 12.1k 96 21.2 388 84.5 2.22k 9.12k
Power Consumption 1.4W DC,1.5VA @ 60Hz AC @ 25C1.5W DC,
1.5VA @ 60Hz AC @ 25C
Dropout Voltage (% of nominal voltage or more) 10% 15% 10% 15% 10% 15% Min. 10% Min. 15%Pull-in Voltage (% of nominal voltage or less) 80% 85% 80% 85% 80% 85% 80% 85%Max. Voltage (Max. continuous voltage) 110% of the rated coil voltage
Contact SpecificationsContact Type 3PDT 4PDTContact Material Silver cadmium oxide, gold flashedMinimum Switching Requirement 100mA @ 5VDCMax. Contact Rating Refer to Contact Ratings charts.Dielectric Strength Between Contacts 1500 V rms 2500V rms
*Note: These devices are rated for 1,000 cycles when applied to a motor application. (Per Table 46.1` UL 508)
*Note: These devices are rated for 1,000 cycles when used in a motor application. (Per Table 45.1, UL 508).
**Note: UL listed when used with sockets 781-1C-SKT, 782-2C-SKT, 783-3C-SKT, 784-4C-SKT, or 784-4C-SKT-1. Current limited to rating of relay orsocket, whichever is less.
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-22Volume 14
78 Series Wiring Diagrams and Dimensions
Wiring Diagrams (viewed from pin end)
13 1 4
1
9
5
(A1) (A2)
781-1C-XXX4 (4 2 )(1 2 ) 1
1 3
(1 4 ) 5 8 (4 4 )
1 4
1 2 (4 1 )(1 1 ) 9
(A 1 ) (A 2 )
782-2C-XXX 784-4C-XXX783-3C-XXX1
5
9
1 4
2
6
1 0
3
7
1 1
4
8
1 2
(A1) (A2)1 3
(12) 1 2 (22) 4 (42)
(14) 5 6 (24) 8 (44)
(11) 9 (21)10 (41)12
(A1) (A2) 13 14
Dimensionsinches [mm]
AALLTTEERRNNAATTEE NNEEMMAA OORR IIEECC (( )) NNUUMMBBEERRSS,, VVIIEEWWEEDD FFRROOMM PPIINN SSIIDDEE
Figure 1: 781-1C
Figure 4: 784-4C
Figure 2: 782-2C
Figure 3: 783-3C
78 Series Relay Socket Dimensions
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-23
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
DIN-rail mounting, SPDT, for usewith 781 series relays
Figure 5: 781-1C-SKT
DIN-rail mounting, DPDT, for usewith 782 series and AD-70S2 relays
Figure 6: 782-2C-SKT
Figure 7: 783-3C-SKT DIN-rail mounting, 3PDT, for use with783 series relays.
Note: Order sockets separately; holding clips are included with sockets.
Note: See Table on next pagefor maximum screw torquesand wire sizes
Note: See Table on next pagefor maximum screw torquesand wire sizes
Note: See Table on next pagefor maximum screw torques andwire sizes
Dimensionsinches [mm]
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-24Volume 14
78 Series Relay Socket Dimensions
Figure 8: 784-4C-SKT-1
DIN-rail mounting, 4PDT,for use with 784 series relays.Note: Order sockets separately;holding clips are included with sockets.
Note: See table below for maximum screwtorques and wire sizes
Part Number Price Maximum Screw Torques Maximum Wire Sizes
781-1C-SKT Terminals 13, 14: 7 in-lbs/0.8NmTerminals 1, 5, 9: 9 in-lbs/1.0Nm
Terminals 13, 14: 18 to 20 AWG, solid or stranded, one or two identical wires
Terminals 1, 5, 9: 12 to 20 AWG, solid or stranded,one or two identical wires
782-2C-SKT All terminals: 9 in-lbs/1.0Nm All terminals: 12 to 20 AWG, solid or stranded,one or two identical wires783-3C-SKT
784-4C-SKT-1
Dimensionsinches [mm]
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-25
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
H782 Series Hermetically Sealed Electromechanical Relay Selection Guide
These ice cube style relays aredesigned for applications requiringhermetically sealed units forhazardous factory locations. (Class I,Div. 2 Groups A, B, C, D).
Specification H782 Series
Coil Voltages 120VAC, 240VAC, 12VAC, 12VDC,24VAC, 24VDCConfiguration 4PDTContact Rating 3A, 5ABase Socket 14 pin spade terminal
Agency ApprovalsUL Recognized (E344123), cULus when used with 782-4C-SKTsocket, CSA, CE, RoHS
Prices starting at
782 Series Hermetically Sealed Relays Selection Guide
Part Number Price Coil Voltage Configuration Contact Rating Dimensions Relay SocketPart Number Price Dimensions
H782-4C3-12D 12VDC
4PDT
3A
Figure 1 782-4C-SKT Figure 2
H782-4C3-12A 12VACH782-4C3-24D 24VDCH782-4C3-24A 24VACH782-4C3-120A 120VACH782-4C3-240A 240VACH782-4C5-12D 12VDC
5A
H782-4C5-12A 12VACH782-4C5-24D 24VDCH782-4C5-24A 24VACH782-4C5-120A 120VACH782-4C5-240A 240VAC
Features Hermetically sealed for use inhazardous locations (Class I, Div. 2 Groups A, B, C, D)
Small package design Silver Cadmium Oxide goldflashed contact High reliability and long life High vibration and shock resistance
Sealed for washdown conditions 4PDT models
H782-4C3-12Ashown
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-26Volume 14
H782 Series Hermetically Sealed Electromechanical Relay Specifications
782 Series Contact Ratings (current)Resistive *Motor Load
Voltage Nominal UL CSA UL30VAC 3A 3A 3A120VAC 3A 3A 3A 1/16 HP240VAC 3A 3A 3A 1/10 HP
782 Series Contact Ratings (current)Resistive *Motor Load
Voltage Nominal UL CSA UL30VAC 5A 5A 5A120VAC 5A 5A 5A240VAC 5A 5A 5A
H782 Series Hermetically Sealed Relay Specification Table
Part Numbers
H782-4C3-12D
H782-4C3-12A
H782-4C3-24D
H782-4C3-24A
H782-4C3-120A
H782-4C3-240A
H782-4C5-12D
H782-4C5-12A
H782-4C5-24D
H782-4C5-24A
H782-4C5-120A
H782-4C5-240A
General Specifications
*Service Life: Mechanical / Electrical Operations Mechanical: 10,000,000 operations unpowered
Electrical life:100,000 operations @ rated resistive load
Operating Temperature -40C to 70C (-40F to 158F)Response Time 20 msAmbient Humidity 45% RH to 85% RHVibration Resistance 3 Gs, 10 to 55Hz (0.6mm double amplitude)Shock Resistance 10 GsWeight 45 g (1.59 oz) **Agency Approvals and Standards UL Recognized File E344123, CE, CSA, RoHSEnvironmental Protection IEC IP67 (Class I, Div. 2 Groups A, B, C, D)NEMA B300 Pilot Duty Rated Yes
Coil SpecificationsCoil Input Voltage 12VDC 12VAC 24VDC 24VAC 120VAC 240VAC 12VDC 12VAC 24VDC 24VAC 120VAC 240VACCoil Resistance 160 43 650 160 3.9k 12k 160 43 650 160 3.9k 12k Power Consumption 0.9W DC; 1.2VA @ 60Hz AC @ 25CDropout Voltage (% of nominal voltage or more) 15% AC, 10%DCPull-in Voltage (% of nominal voltage or less) 85% AC, 80% DCMax. Voltage (Max. continuous voltage) 110% of the rated coil voltage
Contact SpecificationsContact Type 4PDTContact Material Fine silver, gold flashed Silver alloyMinimum Switching Requirement 10 mA @ 5VDC 100mA @ 5VDCMax. Contact Rating Refer to Contact Ratings charts.Dielectric Strength Between Contacts 500V rms
*Note: These devices are rated for 1,000 cycles when used in a motor application. (Per Table 45.1, UL 508).
**Note: UL listed when used with socket 782-4C-SKT. Current limited to rating of relay or socket, whichever is less.
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-27
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
H782 Series Hermetically Sealed Electromechanical Relay Dimensions
0.312 (7.92) LONG#3-48 THREAD
782 HERMETIC MOUNTING OPTIONS
1.28 MAX(32.54)
1.16 MAX(29.36)
0.25(6.35)
0.91 MAX(23.1)
A214
A113
21 31
14
41
32
3424
10 11
6 7
22
44
12
8
422 3 4
0.02(0.508)
IECNEMA
IECNEMA
0.312 (7.92) LONG#3-48 THREAD
782 HERMETIC MOUNTING OPTION S
1.28 MAX(32.54)
1.16 MAX(29.36)
0.25(6.35)
0.91 MAX(23.1)
THREAD AND ANTI-ROTATION TABMOUNTING STUD WITH #6-32
TION
CODE 4STUD ANDTAB LOCATION
0.46 REF.(11.68)A1
13
11 21 31
A214
41
3212
342414
9 10 11
5 6 7
22
44
12
8
421 2 3 4
0.02(0.508)
IECNEMA
Wiring DiagramBottom View
Wiring
Figure 1: H782-4C3-xxand H782-4C5-xx
Dimensionsinches [mm]
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-28Volume 14
Socket for H782 Series Hermetically Sealed Electromechanical Relay
Part Number Price Maximum Screw Torques Maximum Wire Sizes
782-4C-SKT All terminals: 9 in-lbs/1Nm All terminals: 12 to 20 AWG, solid or stranded,one or two identical wires
Figure 2: 782-4C-SKT
Dimensionsinches [mm]
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-29
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
4 56
781
2
3
(A1) (A2)
45 6
10111
23
87
9
(A1) (A2)
75 Series Electromechanical Relay Selection Guide
Features Octal base design Silver Cadmium Oxide, gold flashed contacts
High open contact dielectric strength(1,500 V rms)
High reliability and long life High vibration and shock resistance Flag indicator shows relay status in manualor powered condition
LED indicator on all models, so you caneasily see if relay is working properly without using a voltmeter
A pushbutton allows manual operation ofthe relay without the need for power to thecoil
I.D. tag/write label for identifying relays inmulti-relay circuits
75 Series Relay Selection Guide
Part Number Price Coil Voltage Configuration Contact Rating Dimensions Relay SocketPart Number Price
750-2C-12D 12VDC
DPDT
12A
Figure 1 750-2C-SKT
750-2C-12A 12VAC750-2C-24D 24VDC750-2C-24A 24VAC750-2C-120A 120VAC750-2C-240A 220VAC750-3C-12D 12VDC
3PDT Figure 2 750-3C-SKT
750-3C-12A 12VAC750-3C-24D 24VDC750-3C-24A 24VAC750-3C-120A 120VAC750-3C-240A 240VAC
75 series relays are general purpose relays designed for a wide range of applications,from power to sequence controls in various factory machines and control panels. Theyare ideal for electrical control panels requiring stable and reliable relays.
Order socket separately.
Dimensionsinches [mm]
Wiring750-2C-xxx wiring diagram
750-3C-xxx wiring diagram
Figure 1: 750-2C-xxx
Figure 2: 750-3C-xxx
Note: Contacts and coil shownare internal to the relay
Note: Contacts and coil shownare internal to the relay
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-30Volume 14
75 Series Electromechanical Relay Specifications
75 Series Specification Table
Part Numbers
750-2C-12D
750-2C-12A
750-2C-24D
750-2C-24A
750-2C-120A
750-2C-240A
750-3C-12D
750-3C-12A
750-3C-24D
750-3C-24A
750-3C-120A
750-3C-240A
General SpecificationsService Life Mechanical: 5 million operations, Electrical: 100,000 operations @ rated resistive loadOperating Temperature -40C to 55C (-40F to 131F)Response Time 20 msVibration Resistance 3 Gs @ 10 to 55 Hz(0.6mm double amplitude)Shock Resistance 10 GsWeight 89 g (3.1 oz)*Agency Approvals and Standards UL Recognized file E191059, CE, CSA Certified 244610Environmental Protection IEC IP40
Coil SpecificationsStandard LED IndicatorCoil Input Voltage 12VDC 12VAC 24VDC 24VAC 120VAC 240VAC 12VDC 12VAC 24VDC 24VAC 120VAC 240VAC
Coil Resistance 120 18 470 72 1.7k 7.2k 120 18 470 72 1.7k 7.2k
Power Consumption 3VA (60Hz) AC, 1.4W DC
Dropout Voltage (% of rated voltage) 15% AC, 10% DC
Pull-in Voltage Max. 85% of nominal voltage or less
Max. Voltage (Max. continuous voltage) 110% of the rated coil voltage
Contact SpecificationsContact Type DPDT 3PDTContact Material Silver cadmium oxide, gold flashedMinimum Switching Requirement 100mA @ 5VDCContact Rating Refer to Contact Ratings chartDielectric Strength Between Contacts 1500V rms
75 Series Contact Ratings (current)Resistive Motor Load
Voltage Nominal UL CSA UL
28VDC 12A 12A 12A ---
120VAC 12A 12A 12A 1/3Hp
240VAC 12A 12A 12A 1/2Hp
*Note: UL listed when used with sockets 750-2C-SKT, 750-3C-SKT. Current limited to rating of relay or socket, whichever is less.
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-31
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
H750 Series Hermetically Sealed Electromechanical Relay Selection Guide
H750 series hermetically sealed relays are designed for use in hazardous applications. (Class 1, Div 2, Groups A, B, C, D).
Features Hermetically sealed for use in hazardouslocations (Class 1, Div 2, Groups A, B, C, D)
Octal base design Silver Cadmium Oxide, gold flashed contacts
High open contact dielectric strength(1,500V rms)
High reliability and long life High vibration and shock resistance DPDT and 3PDT models
H750 Series Hermetically Sealed Relay Selection Guide
Part Number Price Coil Voltage Configuration Contact Rating Dimensions Relay SocketPart Number Price
H750-2C-12D 12VDC
DPDT
12A
Figure 1 750-2C-SKT
H750-2C-12A 12VACH750-2C-24D 24VDCH750-2C-24A 24VACH750-2C-120A 120VACH750-2C-240A 220VACH750-3C-12D 12VDC
3PDT Figure 2 750-3C-SKT
H750-3C-12A 12VACH750-3C-24D 24VDCH750-3C-24A 24VACH750-3C-120A 120VACH750-3C-240A 240VAC
Order socket separately.
Specification H750 Series
Coil Voltages 120VAC, 240VAC, 12VAC, 12VDC,24VAC, 24VDCConfiguration DPDT or 3PDTContact Rating 12ABase Socket 8-pin or 11-pin spade terminal,
Agency ApprovalsUL Recognized (E344123), cULus when used with 750 socketsRoHS
Prices starting at
H750-2C-12Dshown
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-32Volume 14
H750 Series Hermetically Sealed Electromechanical Relay Specifications
H750 Series Hermetically Sealed Relays Specification Table
Part Numbers
H750-2C-12D
H750-2C-12A
H750-2C-24D
H750-2C-24A
H750-2C-120A
H750-2C-240A
H750-3C-12D
H750-3C-12A
H750-3C-24D
H750-3C-24A
H750-3C-120A
H750-3C-240A
General Specifications
Service Life Mechanical: 10 million operations
Electrical: 100,000 operations @ rated resistive load
Operating Temperature -40C to 55C (-40F to 131F)Response Time 20 msVibration Resistance 3 G, 10 to 55 HzShock Resistance 10 G Weight 130 g (4.6 oz)*Agency Approvals and Standards UL Recognized file E344123, CSA 244610, RoHSEnvironmental Protection IEC IP67 (Class I, Div. 2 Groups A, B, C, D)
Coil SpecificationsStandard LED IndicatorCoil Input Voltage 12VDC 12VAC 24VDC 24VAC 120VAC 240VAC 12VDC 12VAC 24VDC 24VAC 120VAC 240VAC
Coil Resistance 120 18 470 72 1.7k 7.2k 120 18 72 470 1.7k 7.2k Power Consumption 1.2 VA (60Hz) AC, 0.9W DC 2 VA (60Hz) AC, 1.2W DCDropout Voltage (% of rated voltage) 10% to 15%Pull-in Voltage Max. 85% of nominal voltage or lessMax. Voltage (Max. continuous voltage) 110% of the rated coil voltage
Contact SpecificationsContact Type DPDT 3PDTContact Material Silver alloyMinimum Switching Requirement 100mA @ 5VDCContact Rating Refer to Contact Ratings chartsDielectric Strength Between Contacts 1500V rms
75 Series Contact Ratings (current)Resistive Motor Load
Voltage Nominal UL CSA UL
28VDC 12A 12A 12A ---
120VAC 12A 12A 12A 1/3Hp
240VAC 12A 12A 12A 1/2Hp
*Note: UL listed when used with sockets 750-2C-SKT, 750-3C-SKT. Current limited to rating of relay or socket, whichever is less.
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-33
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
H750 Series Hermetically Sealed Electromechanical Relay Specifications
Dimensions inches [mm]
4 56
781
2
3
(A1) (A2)
H750-2C-xxx wiring diagram
H750-3C-xxx wiring diagram
45 6
10111
23
87
9
(A1) (A2)
Wiring
Figure 1: H750-2C Series8-pin
Figure 2: H750-3C Series11-pin
Note: Contacts and coil shownare internal to the relay
Note: Contacts and coil shownare internal to the relay
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-34Volume 14
75 Series Socket Dimensions
Figure 3: 750-2C-SKT
Figure 4: 750-3C-SKT
Bus Connector
AccessoryPart Number Description Price
33-796-1Coil bus connector used to connect multiplerelays in parallel. Package includes 5 pairs of busbars to connect up to 5 relays together.
Dimensionsinches [mm]
Wiring
Wiring
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-35
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
755 Series Relay Selection Guide
Part Number Price Coil Voltage Configuration Contact Rating Relay Socket Part Price
755-2C-120A 120VACDPDT 16A 750-3C-SKT 755-2C-240A 240VAC
755-2CD-24D 24VDC
Uses 1 1 Pin Octal base (750-3C-SKT, not shown )
AC Operation DC Operation
LineNeutral
LatchLatch
Reset Reset
755 Series Octal Base Magnetic LatchingRelay Selection Guide
Dimensionsinches [mm]
Wiring755 SeriesLatch and reset are designedto be impulse activated.
Features 11-pin octal base (use 750-3C-SKT) installs easily
16 amp contact rating handles most control circuit loads
Permanent magnet latching mechanismholds last set position
Note: Dimensional drawing shows3-pole relay; actual relay is 2-pole.
755-2C-120Ashown
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-36Volume 14
755 Series Octal Base Magnetic LatchingRelay Specifications
755 Series Specifications (@ 25C)
Part Numbers 755-2C-120A(single coil)755-2C-240A(single coil)
755-2CD-24D(double coil)
Contact Specifications
Contact Type DPDT
Contact Material Silver cadmium oxide, gold flashed
Contact Rating 16A @ 120/240VAC 50/60Hz, 16A @ 28VDC
Minimum Switching Requirement 100mA @ 5VDC or 0.5WContact Resistance 50m
Coil Specifications
Standard LED Indicator
Coil Input Voltage 120VAC 240VAC 24VDC
Coil Resistance 10k 3.6k 350
Power Consumption 2VA to 3.55VA (60Hz) ACDropout Voltage (% of rated voltage) N/A
Pull-in Voltage AC: Max. 85% of nominal voltage or lessDC: Max 80% of nominal voltage or lessMax. Voltage (Max. instantaneous voltage) 115% of the rated coil voltage
General Specifications
Service Life Mechanical @ no load: 10 million operations
Electrical: 100,000 operations @ rated resistive load (AC1)
Operating Temperature AC: -30C to 70C (- 22F to 158F)DC: -30C to 75C (- 22F to 167F)Weight 170 g (6 oz)
*Agency Approvals and Standards UL Recognized file E43641, CE Pending, CSA 244610
* UL Listed when used with sockets 750-2C-SKT and 750-3C-SKT. Current limited to rating of relay or socket, whichever is less.
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-37
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
Protection Device Selection Guide
Part Number Price Description Nominal InputVoltageDimensions & Package
MatingSocket
AD-ASMD-250 Protection diode module for 784 and 75 series relays. Plug-in modules come in package of 5. 6-250VDC
Figure 1
783-3C-SKT784-4C-SKT-1750-2C-SKT750-3C-SKT
AD-ASMM-24
MOV module for 784 and 75 series relays that operate at 24VAC coil voltage. Package includes 5modules. 24VAC/VDC
AD-ASMM-120 MOV module for 784 and 75 series relays that operate at 120VAC coil voltage. Package includes 5modules. 120VAC/VDC
AD-ASMM-240 MOV module for 784 and 75 series relays that operate at 240VAC coil voltage. Package includes 5modules. 240VAC/VDC
AD-BSMD-250 Protection diode module for 782 series relays. Plug-in modules come in package of 5. 6-250VDC
Figure 2 782-2C-SKTAD-BSMM-24 MOV module for 782 series relays that operate at 24VAC coil voltage. Package includes 5 modules. 24VAC/VDC
AD-BSMM-120 MOV module for 782 series relays that operate at 120VAC coil voltage. Package includes 5 modules. 120VAC/VDC
AD-BSMM-240 MOV module for 782 series relays that operate at 240VAC coil voltage. Package includes 5 modules. 240VAC/VDC
1.37(34.7)
1.45(38.8)
0.384(9.82)
0.490(12.4)
0.900(22.8)
0.34(8.63)
Figure 1 Figure 2
A2 A1M.O.V .
A2 A1
DIODE
Packaged M.O.V.s and Diodes
Accessory dimensionsinches [mm]
OverviewMetal Oxide Varistors (MOV) and Diodecircuits are offered as convenient plug-inmodules. Plugging a module into therelay socket connects the circuit in parallelwith the relay coil. No additional wiring isrequired.
Modules fit within the maximum dimen-sions of the relay and socket.
Features MOVs protect by shunting potentiallydamaging electrical spikes away from therelay coil. Ideal for AC and DC applications.
Diodes protect external drive circuitry from inductive voltages generated when removing coil voltage.Ideal for DC applications. Polarity sensitive.
ApplicationMany PLC systems control one or moreinductive load devices. These inductiveloads (devices with a coil) generate tran-sient voltages when they are de-energizedwith a relay contact. When a relay contactis closed it bounces, which causes thecoil to energize and de-energize until thebouncing stops. The transient voltagewhich is generated is much larger inamplitude than the supply voltage, espe-cially with a DC supply voltage.
When switching a DC-supplied inductiveload the full supply voltage is alwayspresent when the relay contact opens (orbounces). When switching an AC-supplied inductive load, if the voltageis not zero when the relay contact opens,there is energy stored in the inductor thatis released when the voltage to theinductor is suddenly removed. This releaseof energy is what produces transient voltages.
When inductive load devices (motors,motor starters, interposing relays, sole-noids, valves, etc.) are controlled withrelay contacts, it is recommended that asurge suppression device be connecteddirectly across the coil of the field device.If the inductive device has plug-typeconnectors, the suppression device can beinstalled on the terminal block of the relayoutput.
Metal oxide varistors (MOV) and diodesare devices which provide good surgeand transient suppression of AC and DCpowered coils.
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-38Volume 14
Figure 2AD-PR40-2A-xx
Power Relays
Power Relay Selection GuidePart Number Price Coil Voltage Configuration Contact Rating Price DimensionsAD-PR40-1C-12D 12VDC
SPDT
40A
Figure 1AD-PR40-1C-24D 24VDCAD-PR40-1C-24A 24VACAD-PR40-1C-120A 120VACAD-PR40-1C-240A 240VACAD-PR40-2A-12D 12VDC
DPST Figure 2AD-PR40-2A-24D 24VDCAD-PR40-2A-24A 24VACAD-PR40-2A-120A 120VACAD-PR40-2A-240A 240VACAD-PR40-2C-12D 12VDC
DPDT Figure 3AD-PR40-2C-24D 24VDCAD-PR40-2C-24A 24VACAD-PR40-2C-120A 120VACAD-PR40-2C-240A 240VAC
Features High power contacts capable of switching up to 40A Open construction SPDT, DPST and DPDT models Riveted construction for high reliability Maximum contact voltage up to 600V
SPDT DPDT DPST
22
12
A1
A2 11
2124
14
A1
A2 11
2124
14
14
12
A1
A2 11
WiringAD-PR40-1C-xxxx AD-PR40-2C-xxxx AD-PR40-2A-xxxx
Figure 1 AD-PR40-1C-xx
Dimensions inches [mm]
AD-PR40-1C-12Dshown
Figure 3 AD-PR40-2C-xx
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-39
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
Power Relays SpecificationsPower Relays Specification Table
Part Numbers
AD-PR40-1C-12D
AD-PR40-1C-24D
AD-PR40-1C-24A
AD-PR40-1C-120A
AD-PR40-1C-240A
AD-PR40-2A-12D
AD-PR40-2A-24D
AD-PR40-2A-24A
AD-PR40-2A-120A
AD-PR40-2A-240A
AD-PR40-2C-12D
AD-PR40-2C-24D
AD-PR40-2C-24A
AD-PR40-2C-120A
AD-PR40-2C-240A
General Specifications
Service Life Mechanical: 1 million operations AC and DC
Electrical: 50,000 operations @ 300VAC/100,000 @ 28VDC
Operating Temperature -55C to 55C (-67F to 131F)Response Time 30 msWeight 227g ( 8 oz) to 312g (11 oz)Agency Approvals and Standards UL Recognized E191059, CE Certified (9667186-9811), CSA Certified 244610, RoHSEnvironmental Protection Not applicable to open relaysPilot Duty A600Terminal Wire Max 10 AWGTerminal Torque 11 to 15 in-lb (1.2 to 1.7 Nm)
Coil SpecificationsCoil Input Voltage 12VDC 24VDC 24VAC 120VAC 240VAC 12VDC 24VDC 24VAC 120VAC 240VAC 12VDC 24VDC 24VAC 120VAC 240VACCoil Resistance 70 290 12 290 1.2k 70 290 12 290 1.2k 70 290 12 290 1.2k Power Consumption 60Hz, 10VA (AC) , 4.0W DCDropout Voltage (% of rated voltage) Min. 10%Pull-in Voltage Max. 85% of nominal voltage or less AC, Max. 80% of nominal voltage or less DCMax. Voltage (Max. continuous voltage) 110% of the rated coil voltage
Contact SpecificationsContact Type SPDT DPST DPDTContact Material Silver cadmium oxide, gold flashedContact Rating 40A @ 300VAC or 28VDC; 2HP motor loadMinimum Switching Requirement 1A @ 5VAC/VDCMaximum Switching Voltage 600V @ 5A Dielectric Strength Between Contacts 1600V rms
Dimensions inches [mm]
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-40Volume 14
AD Series Solid State Relays
AD-70S2-04Bshown
Solid State Relay Selection Guide
Part Number Price Description Dimensions & Derating ChartsRelay SocketPart Number Price
SocketDimensions
AD-SSR210-AC Solid state DIN-rail mount relay with 10A contact rating. Coil voltage 90-280VAC.Load voltage is 24-280VAC. Finger-safe design and LED status lamp.
Figure 1 N/A N/A N/AAD-SSR225-AC Solid state DIN-rail mount relay with 25A contact rating. Coil voltage 90-280VAC.Load voltage is 24-280VAC. Finger-safe design and LED status lamp.AD-SSR210-DC Solid state DIN-rail mount relay with 10A contact rating. Coil voltage 3-32VDC. Loadvoltage is 24-280VAC. Finger-safe design and LED status lamp.AD-SSR225-DC Solid state DIN-rail mount relay with 25A contact rating. Coil voltage 3-32VDC. Loadvoltage is 24-280VAC. Finger-safe design and LED status lamp.AD-70S2-04B Solid state plug-in relay with 4A contact rating. Coil voltage is 3-30VDC. Load voltage is 24-140VAC.
Figure 2782-2C-SKT(see wiring
diagram on nextpage)
Figure 6 *AD-70S2-04C Solid state plug-in relay with 4A contact rating. Coil voltage is 3-30VDC. Load voltage is 24-280VAC.AD-70S2-04D Solid state plug-in relay with 4A contact rating. Coil voltage is 3-30VDC. Load voltage is 8-50VAC.
AD-SSR210-DC shown
A solid state relay is a relay with isolatedinput and output, whose functions areachieved by means of using electroniccomponents without the use of movingparts (vs.electromechanical relays).
OperationSolid state relays (SSR) are similar toelectromechanical relays, in that both use acontrol circuit and a separate circuit forswitching the load. When voltage isapplied to the input of the SSR, the relay isenergized by a light-emitting diode. Thelight from the diode is beamed into a lightsensitive semiconductor which, in the caseof zero voltage crossover relays, signals thecontrol circuit to turn on the output of thesolid state switch at the next zero voltagecrossover.
Solid State Relay FeaturesSolid state relays have features whichelectromechanical relays do not, such as:
Long life Shock and vibration resistant No generation of RFI, EMI No contact bounce Arcless switching No acoustic noise Zero crossing IC compatibility Immunity to humidity, salt spray and dirt UL # E222847
AD-SSR Features AC & DC input AC output 10 or 25 amp loads Photo isolated zero voltage switching 4000V rms isolation input to output Internal RC (snubber) network RFI suppression Integral safety cover and heatsink DIN-rail mounting or panel-mount
AD-70S2 Features DC input AC output Up to 4 amp loads Optically isolated Quick connect terminal, or panel mountwhen inserted into DIN-rail mountablesocket
*NOTE: See 78 Series Relays Socket Dimensions.
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-41
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
Solid State Relay Specifications
Specifications
Part Number
AD-SSR210-DC
AD-SSR210-AC
AD-SSR225-DC
AD-SSR225-AC
AD-70S2-04B
AD-70S2-04C
AD-70S2-04D
Input CharacteristicsControl Voltage Range 3-32 VDC 90-280 VAC 3-32 VDC 90-280 VAC 3-30 VDC
Typical Input Current 16 mA 12 mA 16 mA 12 mA 1-17 mA
Must Release Voltage 1 VDC 10 VAC 1 VDC 10 VAC 1.0 VDC
Reverse Polarity Protection Yes N/A Yes N/A No
Maximum Reverse Control Voltage N/A 5 VDC
Power Indicator Red LED Status Lamp N/A
Output CharacteristicsLoad Voltage Range 24-280VAC 24-140 VAC 24-280 VAC 8-50 VAC
Rated Load Current 10 A 25 A 4 A 4 A 4 A
Maximum Off-State Voltage dv/dt 200 s 500 s 3000 V / s Typical
Minimum Load Current 50 mA 120 mA 75 mA
Non-Repetitive Surge Current (1 Cycle) 83 A 800 A 60 A Peak Max. @ 25C
Maximum Off State Leakage current (RMS) 10 mA 6 mA 3 mA
Typical On-State Voltage Drop (RMS) 1.25 VAC 1.35 VAC 1.6 VAC
Maximum I 2T for Fusing (A2Sec) 83 3700 N/A
Maximum Peak Blocking Voltage N/A 400 V 600 V 200 V
Operating Frequency Range 25 Hz to 70 Hz
Maximum Turn-On Time 10ms 40ms 10ms 40ms 8.3 ms
Maximum Turn-Off Time 10ms 80ms 10ms 80ms 8.3 ms
General CharacteristicsDielectric Strength (Input-to-Output Isolation) 4000 V rms 3000 V rms
Insulation Resistance 1010 Min.
Operating Temperature Range -30C to 80C -40C to 100C
Storage Temperature Range -40C to 100C -40C to 125CWeight 12.35 oz. (350 g) approx. 1.4 oz. (40 g) approx.Agency Approvals UL Recognized, CE, CSA
INPUT
OUTPUT
3 + - 4
12
AD-SSRxxx-xx wiring diagram
A1 (-)
A2 (+)12 (41)8 (44)
AD-70S2-xx wiring diagram
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-42Volume 14
SSR Series Dimensions & Derating Charts
1.200 (30.48)
0.830(21.08)
1.000(25.4)
0.187 (4.74)
1.181(30)
4.527 MAX.(115)
3.050 (77.47)
1.20(30.5)
3.188 MAX.(80.97)
0.468(11.9)
4.015 (102)
3.62 (91.940)
0.866(22)
0.196(5.0)
0.5515 (14)
10 Amp Styles
LOA
D CU
RR
ENT
(AM
PS R
MS)
0 10 20 30 40 50 60 70 80 90
10
12
8 6
420
MAX. AMBIENT TEMPERATURE (C)
0
2520
MAX. AMBIENT TEMPERATURE (C)LO
AD
CU
RR
ENT
(AM
PS R
MS)
15105
0 10 20 30 40 50 60 70 80 90
25 Amp Styles
AD-SSR Series
AD-70S2 Series
AD-SSR Series derating charts
AMBIENT TEMPERATURE (C)-40 -20 0 20 40 60 80 100
87654321
LOA
D CU
RR
ENT
(AM
PS)
AD-70S2 Series derating charts
Figure 1
Figure 2
0.565(14.35)
0.085(2.15)
0.220(5.58)
0.280(7.11)
0.285(7.23)
0.232(5.84)
Note: Recommended spacing between multiple SSRs is 0.75 inch.
Dimensionsinches [mm]
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-43
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
AD Series Class 6 Solid State Relays
Class 6 Solid State Relay Selection Guide
Part Number Price Type Input Voltage Load Voltage Configuration Contact Rating
AD-SSR610-AC-280A N.O. SCR 90 to 280 VAC
24 to 280 VAC
SPST
10AAD-SSR610-DC-280A N.O. SCR 3 to 32 VDCAD-SSR6T10-DC-280A N.O. TRIAC 3 to 32 VDCAD-SSR625-AC-280A N.O. SCR 90 to 280 VAC
25AAD-SSR625-DC-280A N.O. SCR 3 to 32 VDCAD-SSR6T25-DC-280A N.O. TRIAC 3 to 32 VDCAD-SSR640-AC-280A N.O. SCR 90 to 280 VAC
40AAD-SSR640-DC-280A N.O. SCR 3 to 32 VDCAD-SSR6T40-DC-280A N.O. TRIAC 3 to 32 VDCAD-SSR650-AC-280A N.O. SCR 90 to 280 VAC
50AAD-SSR650-DC-280A N.O. SCR 3 to 32 VDCAD-SSR675-AC-280A N.O. SCR 90 to 280 VAC
75AAD-SSR675-DC-280A N.O. SCR 3 to 32 VDCAD-SSR6M12-DC-200D N.O. MOSFET 3.5 to 32 VDC
3 to 200 VDC
12A
AD-SSR6M25-DC-200D N.O. MOSFET 3.5 to 32 VDC 25AAD-SSR6M40-DC-200D N.O. MOSFET 3.5 to 32 VDC 40AAD-SSR610-AC-480A N.O. SCR 90 to 280 VAC
48 to 480 VAC
10AAD-SSR610-DC-480A N.O. SCR 3 to 32 VDCAD-SSR6T10-DC-480A N.O. TRIAC 3 to 32 VDCAD-SSR625-AC-480A N.O. SCR 90 to 280 VAC
25AAD-SSR625-DC-480A N.O. SCR 3 to 32 VDCAD-SSR6T25-DC-480A N.O. TRIAC 3 to 32 VDCAD-SSR640-AC-480A N.O. SCR 90 to 280 VAC
40AAD-SSR640-DC-480A N.O. SCR 3 to 32 VDCAD-SSR6T40-DC-480A N.O. TRIAC 3 to 32 VDC
The Class 6 solid state relays offer anenergy-efficient alternative to standardelectromechanical relays.
Switching types include DC switching forlow-voltage DC loads and Zero Cross forresistive AC loads where the output ener-gizes/de-energizes when control voltage isnear zero.
Switching devices include: MOSFET for DCloads, Triac and SCR for AC loads.
Features Finger-safe Hockey Puck housing Solid-state circuitry High load ratings up to 75 amps Input indicating LED Optically coupled circuits Panel mount Thermal pad included with each relay
Note: Thermal pad included with each relay.
AD-SSR610-AC-280Ashown
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-44Volume 14
AD Series Class 6 Solid State Relays
Specifications
Part Number
AD-SSR610-AC-280A
AD-SSR610-DC-280A
AD-SSR6T10-DC-280A
AD-SSR625-AC-280A
AD-SSR625-DC-280A
AD-SSR6T25-DC-280A
AD-SSR640-AC-280A
AD-SSR640-DC-280A
AD-SSR6T40-DC-280A
AD-SSR650-AC-280A
AD-SSR650-DC-280A
AD-SSR675-AC-280A
AD-SSR675-DC-280A
Input Characteristics
Control Voltage Range 90 to 280VAC 3 to 32 VDC90 to 280VAC 3 to 32 VDC
90 to 280VAC 3 to 32 VDC
90 to 280VAC
3 to 32VDC
90 to 280VAC
3 to 32VDC
Maximum Input Current 2 mA 10 mA 2 mA 10 mA 2 mA 10 mA 2 mA 10 mA 2 mA 10 mAMust Release Voltage 10 VAC 1 VDC 10 VAC 1 VDC 10 VAC 1 VDC 10 VAC 1 VDC 10 VAC 1 VDCReverse Polarity Protection no no no no noSwitching Type Zero CrossPower Indicator Green LED status lamp
Output CharacteristicsLoad Voltage Range 24 to 280 VACRated Load Current 10 A 25 A 40 A 50 A 75 AMaximum Off-State Voltage dv/dt 500 V/s
Minimum Load Current 40 mA 150 mA 40 mA 150 mA 40 mA 150 mA 40 mA 150 mA 40 mA 150 mAMaximum Non-Repetitive Surge Current (1 Cycle, 16.6 ms), peak 120 A 250 A 625 A 1000 A
Maximum Off State Leakage current (RMS) 10 mA 1 mA 10 mA 1 mA 10 mA 1 mA 10 mA 1 mA 10 mA 1 mA
Maximum On-State Voltage Drop (RMS) 1.6 V rms
Maximum I 2T for Fusing (A2Sec) 60 260 1620 4150
Operating Frequency Range 50 to 60 HzMaximum Turn-On Time 10 ms 8.3 ms 10 ms 8.3 ms 10 ms 8.3 ms 10 ms 8.3 ms 10 ms 8.3 msMaximum Turn-Off Time 40 ms 8.3 ms 40 ms 8.3 ms 40 ms 8.3 ms 40 ms 8.3 ms 40 ms 8.3 ms
General CharacteristicsDielectric Strength (Input-to-Output Isolation) 4000 VAC (rms)
Thermal Resistance (Junction to Base) 1.48C/W (34.66F/W) 1.02C/W (33.84F/W) 0.63C/W (33.13F/W) 0.31C/W (32.56F)
Minimum Insulation Resistance@ 500 VDC 1
E + 9
Operating Temperature Range -40C to 80C (-40 to 176F) derating appliesStorage Temperature Range -40C to 125C (-40F to 257F)Weight 86.5 g (3.05 oz)Terminal Torque Input terminals: 10 lb-in. Output terminals: 20 lb-inAgency Approvals and Standards UL file # E222847 CE, CSA, RoHS
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-45
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
Specifications
Part Number
AD-SSR6M
12-DC-200D
AD-SSR6M
25-DC-200D
AD-SSR6M
40-DC-200D
AD-SSR610-AC-480A
AD-SSR610-DC-480A
AD-SSR6T10-DC-480A
AD-SSR625-AC-480A
AD-SSR625-DC-480A
AD-SSR6T25-DC-480A
AD-SSR640-AC-480A
AD-SSR640-DC-480A
AD-SSR6T40-DC-480A
Input Characteristics
Control Voltage Range 3.5 to 32 VDC 90 to 280VAC 3 to 32 VDC90 to 280VAC 3 to 32 VDC
90 to 280VAC 3 to 32 VDC
Maximum Input Current 10 mA 4 mA 15 mA 4 mA 15 mA 4 mA 15 mAMust Release Voltage 1 VDC 10 VAC 1 VDC 10 VAC 1 VDC 10 VAC 1 VDCReverse Polarity Protection no no no noSwitching Type DC Zero CrossPower Indicator Green LED status lamp
Output CharacteristicsLoad Voltage Range 3 to 200 VDC 48 to 480 VACRated Load Current 12 A 25 A 40 A 10 A 25 A 40 AMaximum Off-State Voltage dv/dt 500 V/s
Minimum Load Current 40 mA 150 mA 40 mA 150 mA 40 mA 150 mAMaximum Non-Repetitive Surge Current (1 Cycle, 16.6 ms), peak 27 A 50 A 90 A 140 A 250 A 625 A
Maximum Off State Leakage current (RMS)
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-46Volume 14
AD Series Class 6 Solid State RelaysDimensions & Derating ChartsDimensionsinches [mm]
1.5 C/W
0.14 C/W
0.14 C/W (50A)
12 A MOSFET 25/40 A MOSFET
0
50
40
30
20
10
10 20 30 40 50 60 70 80
Load
Cur
rent
(Arm
s)
Mounted on heat sink with0.5 C/W thermal resistance
0
50
40
30
20
10
10 20 30 40 50 60 70 80
Load
Cur
rent
(Arm
s)
Mounted on heat sink with3.2 C/W thermal resistance
Mounted on heat sink with0.5 C/W thermal resistance
Derating Charts
AD-SSR6Mxx-DC-200DAD-SSR6xx-xC-xxxA
Note: Charts are based on using a thermal transfermedium such as the included thermal pad
Relays and Timersw w w . a u t o m a t i o n d i r e c t . c o m / r e l a y s e27-47
CompanyInformation
SystemsOverview
ProgrammableControllers
Field I/O
Software
C-more & other HMI
Drives
SoftStarters
Motors &Gearbox
Steppers/Servos
Motor Controls
ProximitySensors
Photo Sensors
Limit Switches
Encoders
CurrentSensors
PressureSensors
TemperatureSensors
Pushbuttons/Lights
Process
Relays/Timers
Comm.
TerminalBlocks & Wiring
Power
CircuitProtection
Enclosures
Tools
Pneumatics
Safety
Appendix
ProductIndex
Part #Index
Volume 14
AD Series Class 6 Solid State RelaysAccessory
Accessory for SSR6 Solid State Relay
Part Number Price Description
AD-SSR-THERM-PAD Thermal mounting pad for AD-SSR6 solid state relays OONNLLYY. 10/pk.
Dimensionsinches [mm]
Relays and Timers 1 - 8 0 0 - 6 3 3 - 0 4 0 5e27-48Volume 14
AD Series Class 8 Solid State Relays
Class 8 Solid State Relay Selection Guide
Part Number Price Type Input Voltage Load Voltage Configuration Contact Rating
AD-SSR810-AC-28Z
N.O. SCR
90 to 280 VAC
24 to 280 VAC
SPST 10A
AD-SSR810-AC-28R AD-SSR810-DC-28Z
3 to 32 VDCAD-SSR810-DC-28R AD-SSR810-DC-28RN N.C. SCR 3 to 32 VDCAD-SSR810-AC-48Z
N.O. SCR
90 to 280 VAC
48 to 480 VACAD-SSR810-AC-48R AD-SSR810-DC-48Z
3 to 32 VDCAD-SSR810-DC-48R AD-SSR810-AC-60Z
90 to 280 VAC
48 to 600 VACAD-SSR810-AC-60R AD-SSR810-DC-60Z
3 to 32 VDCAD-SSR810-DC-60R
AD-SSR810-AC-28Zshown
Features Internal heat sink Finger-safe terminals DIN and panel mounting Optically coupled circuit
The Class 8 solid state relays offer energyefficient current switching in a slimhousing ideal for space-saving applica-tions.
Switching types include Zero Cross forresistive AC loads where the output energizes/de-energizes when controlvoltage nears zero, and Random for ACloads where the output switches instantaneously with the actual voltage.
All Class 8 solid state relays use an SCR,which is suited for AC load applications,as the switching device .