8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
1/104
CBB_A04_E1OMC Radio Parameters Introduction
ZTE University
CDMA-BSS Course Team
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
2/104
Main Content
BSS Parameters
BTS Parameters
Cell Parameters
Carrier Parameters
Channel Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
3/104
BSS Parameter
BSS Parameters
Forward Power Control Parameters
1X Forward Power Control
Parameters
Reverse Power Control Parameters
BSS Neighbor Cell
BSC Handoff Parameters
Gain Parameters
RLP Parameters
PTT SCH Parameters
Pay Phone Parameters
Special Number Parameters
Switch Parameters
There are twelve parameter tables in BSS grade.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
4/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
5/104
BSS Parameters
MSC ID
Description :Switch ID.
Service provider specifies this parameter. The first 16 digits represent Market
ID. The last 8 digits represent the Switch number.
Value Range: 0 ~ 255.
Setting: Network operator maintains this parameter. It is unchangeable at
background.
MS MCC :Mobile Country Code
Value Range: 000~999
Default: 460
Description: It is the first three digits of the International Mobile Station Identity
(IMSI).
China = 460, USA = 310, Canada =302a, Singapore = 525.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
6/104
BSS Parameters
MS MNC: Mobile Network Code
Value Range: 00~99
Default: 03
Description: part of the IMSI.
MS IMSI_11_12 Value Range: 00~99
Default: 03
Description: the eleventh and twelfth digits of the IIMSI, when IMSI is 15 digitals
in length IMSI_11_12 is equal to MNC.
An IMSI that is 15 digits in length is called a class0 IMSI (the NMSI is 12
digits in length); an IMSI that is less than 15 digits in length is called a
class 1 IMSI (the NMSI is less than 12 digits in length).
IMSI Structure
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
7/104
BSS Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
8/104
BSS Parameters
Intercurrent Voice and data supported indicator Value Range: 0, 1 Default: 0 Description: Indication of BS concurrent service beingsupported.
Packet data services zone id (Data service) Value Range: 0 255 Default: 1Description: If the base station supports a packet data
service zone, the base station shall set this field to itsnon-zero packet data services zone identifier. If thebase station does not support a packet data servicezone, the base station shall set this field to 0.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
9/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
10/104
BSS Parameter
BSS Parameters
Forward Power Control Parameters
1X Forward Power Control Parameters
Reverse Power Control Parameters
BSS Neighbor Cell
BSC Handoff Parameters
Gain Parameters
RLP Parameters
PTT SCH Parameters
Pay Phone Parameters
Special Number Parameters
Switch Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
11/104
Forward Power Control Parameters
This is for CSM1500
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
12/104
BSS Parameter
BSS Parameters
Forward Power Control Parameters
1X Forward Power Control Parameters
Reverse Power Control Parameters
BSS Neighbor Cell
BSC Handoff Parameters
Gain Parameters
RLP Parameters
PTT SCH ParametersPay Phone Parameters
Special Number Parameters
Switch Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
13/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
14/104
1X Forward Power Control Parameters
MS Power control step size1/2/3
Value Range: 0~2
Default: MS Power control step size 1:0
MS Power control step size 2:1MS Power control step size 3:2
Description: Step length of reverse close loop power control (1 leg, 2
or more legs). In terms of power control bits in power control
subchannel, MS adjusts transmission power according to this step
length.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
15/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
16/104
This is for reverse closedPower control setpoint For example:13000: 21-13=8 dB
Reverse Power Control Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
17/104
BSS Parameter
BSS ParametersForward Power Control Parameters
1X Forward Power Control Parameters
Reverse Power Control Parameters
BSS Neighbor Cell
BSC Handoff Parameters
Gain Parameters
RLP Parameters
PTT SCH Parameters
Pay Phone Parameters
Special Number Parameters
Switch Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
18/104
BSS Neighbor cell
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
19/104
BSS Neighbor cell
Press here, system will jump this windows.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
20/104
Neighbor cell parameters
Global neighbor cell ID Value Range: 0~1023 Default: - Description: Global neighbor cell Id is generated by backgroundautomatically. It is unchangeable.
Global neighbor cell typeValue Range: 0,1
Default: -Description: There is or there isn t relationship between BSC of localcell and BSC of neighbour cell. Not Protocol Filed.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
21/104
Neighbor cell parameters
CI Discriminator: Neighbor cell discrimination mode.
Value Range: 1,2,5,7
Default: 2
Description: Not Protocol Filed.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
22/104
Neighbor cell parameters
MarketId: (A unique market identity provided by aservice provider )
Value Range: 0~65535Default:-
Description: When the CI Discriminator isn t 7 , Location, Market Id and Switch Number are inactivated.
SwitchNumberValue Range: 0~255Default: -Description: used to uniquely identify a specialswitching center in a group of switching centers underthe same Market ID. when CI_Discriminator equals to 7,SwitchNumber is valid and used to construct MSCID.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
23/104
BSS Parameter
BSS Parameters
Forward Power Control Parameters
1X Forward Power Control Parameters
Reverse Power Control Parameters
BSS Neighbor Cell
BSC Handoff Parameters
Gain Parameters
RLP Parameters
PTT SCH Parameters
Pay Phone Parameters
Special Number Parameters
Switch Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
24/104
BSC Handoff Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
25/104
BSC Handoff Parameters
Hard handoff support RC3 and up indicator .
Value Range: 0,1
Default: 1
Description: Indication of 1X hard handoff being
supported. If not support, the MS of RC3 or above are
treated as IS-95 MS. This parameter is used in hard
handoff with disconnected BSC.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
26/104
BSC Handoff Parameters
Parameters as Search window are default .
Value Range: 0,1
Default: 0
Description: Indication of set the parameters such as
search window and etc. in default. This parameter is
used in hard handoff with disconnected BSC.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
27/104
BSC Handoff Parameters
SOWD and TOWD include hardware delay
Value Range: 0,1
Default: 1
Description: SOWD and TOWD contain hardware delay
indication. This parameter is used in the hard handoff
with disconnected BSC.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
28/104
BSS Parameter
BSS Parameters
Forward Power Control Parameters
1X Forward Power Control Parameters
Reverse Power Control Parameters
BSS Neighbor Cell
BSC Handoff Parameters
Gain Parameters
RLP Parameters
PTT SCH Parameters
Pay Phone Parameters
Special Number Parameters
Switch Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
29/104
BSS Parameter
Gain ParametersRLP ParametersPTT SCH ParametersPay Phone ParametersSpecial Number Parameters
Switch Parameters
In the most of the conditions, the default valueis used in these parameter tables.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
30/104
Main Content
BSS Parameters
BTS Parameters
Cell Parameters
Carrier Parameters
Channel Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
31/104
BTS Parameters
The parametersof this table areused for EV-DO
service!
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
32/104
BTS Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
33/104
1X Forward Power ControlParameters/Switch Parameters
Forward power uprise step size(1/2/3 leg)
Value Range: 1 ~ 7. The unit is 0.25dB
Default: Forward power uprise step size(1 leg) = 4
Forward power uprise step size(2 leg) = 2
Forward power uprise step size(3 leg) = 1
Description: Forward power control uprising step length. If the power
control step length is set too high, the forward quick power control
response time is short, but the stable state power deviation is high. Ifthe power control step length is set too low, the stable state power
deviation is low, but the forward quick power control response time is
long.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
34/104
1X Forward Power ControlParameters/Switch Parameters
Forward power down step size(1/2/3 leg)
Value Range: 1 ~ 7. The unit is 0.25dB
Default: Forward power down step size(1 leg) = 4
Forward power down step size(2 leg) = 2
Forward power down step size(3 leg) = 1
Description: Forward power control descending step length. If the
power control step length is set too high, the forward quick power
control response time is short, but the stable state power deviation ishigh. If the power control step length is set too low, the stable state
power deviation is low, but the forward quick power control response
time is long.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
35/104
BTS Parameters
Power
The powerassigned by BTSto a subscriber.
Maximum
Minimum
Initial
These two parametersdecide Maximum
threshold andMinimum threshold
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
36/104
1X Forward Power ControlParameters/Switch Parameters
RCC2 FCH initial power (voice)Value Range: 163~203. The unit is DGU
Default: 179
Description: RC3/4/5 voice service F-FCH initial transmitting power. If
the initial transmitting power is set too high, F-FCH initial transmitting
power is high, and the MS is easier to receive information correctly
(Frame Error Rate is low), but the forward capacity is lowered when
the channel is established. If the initial transmitting power is set too
low, F-FCH initial transmitting power is low, and the MS may receive
wrong information (Frame Error Rate is high), but the forward power
resource is saved.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
37/104
1X Forward Power ControlParameters/Switch Parameters
Nominal transmit power for voice (1/2/3 leg)
Value Range: 1~255. The unit is DGU
Default: Nominal transmit power for voice (1 leg) = 169
Nominal transmit power for voice (2 leg) = 175
Nominal transmit power for voice (3 leg) = 171
Description: Voice service nominal power.
Power region for voice (1/2/3 leg)
Value Range: 1~255. The unit is DGU
Default: Power region for voice (1 leg) = 80
Power region for voice (2 leg) = 40
Power region for voice (3 leg) = 32
Description: Voice service power variation region.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
38/104
Main Content
BSS Parameters
BTS Parameters
Cell Parameters
Carrier Parameters
Channel Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
39/104
Cell Parameter
Cell Parameter
System Parameter
Power Control Reporting Parameter
Handoff Parameter
Reverse Link Overload Parameter
SCH Rate Parameter
Redirect Message Parameters
Link Cell
Neighbor Frequency
ECAM Information Repeat Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
40/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
41/104
Cell Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
42/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
43/104
Cell Parameter
Cell Identity : CI Value Range: 0~65535
Default:-
Description: Each cell has a unique CI.
Pilot PN sequence offset: PILOT_PN
Value Range: 0~511
Unit: 64PN chip
Description: Protocol Field.
Pilot PN sequence offset index increment: PILOT_INC
Value Range: 0~15
Unit: 64PN chip
Default: 4
Description: Protocol Field.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
44/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
45/104
Cell Parameter
Cell ParameterSystem Parameter
Power Control Reporting Parameter
Handoff Parameter
Reverse Link Overload Parameter
SCH Rate Parameter
Redirect Message Parameters
Link Cell
Neighbor Frequency
ECAM Information Repeat Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
46/104
System Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
47/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
48/104
Cell Parameter
Cell Parameter
System Parameter
Power Control Reporting Parameter
Handoff Parameter
Reverse Link Overload Parameter
SCH Rate Parameter
Redirect Message Parameters
Link Cell
Neighbor Frequency
ECAM Information Repeat Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
49/104
Power Control Reporting Parameter
For forward slow powerControl.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
50/104
Cell Parameter
Cell Parameter
System Parameter
Power Control Reporting Parameter
Handoff ParameterReverse Link Overload Parameter
SCH Rate Parameter
Redirect Message Parameters
Link Cell
Neighbor Frequency
ECAM Information Repeat Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
51/104
Handoff Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
52/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
53/104
Handoff Parameters
Pilot detection threshold: T_ADDValue range: 0 ~ 47 Default: 26 Unit: -0.5dbDescription: be used to trigger a mobile station to send a pilot signalstrength measurement message to start the handoff process.
Pilot drop threshold: T_DROPValue range: 0 ~ 47 Default: 30 Unit: -0.5dbDescription: be used to trigger a mobile station to send a pilot signalstrength measurement message to start the handoff drop process.
Active Set versus Candidate Set comparison threshold: T_COMPValue range: 0 ~ 15 Default: 5 Unit: 0.5dBDescription: be used to control the transfer of pilot signals from the
candidate set to the active set.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
54/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
55/104
IS-2000 Soft Handoff algorithm
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
56/104
Dynamic Add Threshold: [(SOFT_SLOPE/8) 10 log10(PS1) + ADD_INTERCEPT/2]Dynamic Drop Threshold : [(SOFT_SLOPE/8) 10 log10(PS2) + DROP_INTERCEPT/2]
IS-2000 Soft New Parameters
Slope in the inequality criterion for adding or dropping a pilot :SOFT_SLOPEValue range: 0 ~ 63 Default: 0 Unit: -Description: Soft handoff slope .
Intercept in the inequality criterion for adding a pilot to Active Set: ADD_INTERCEPT
Value range: 0 ~ 63 Default: 26 Unit: -0.5dBDescription: Add soft handoff intercept.
Intercept in the inequality criterion for dropping a pilot from the Active Set: DROP_INTERCEPT
Value range: 0 ~ 63 Default: 30 Unit: -0.5dBDescription: Drop soft handoff intercept .
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
57/104
Cell Parameter
Cell ParameterSystem Parameter
Power Control Reporting Parameter
Handoff Parameter
Reverse Link Overload Parameter
SCH Rate Parameter
Redirect Message Parameters
Link Cell
Neighbor Frequency
ECAM Information Repeat
Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
58/104
Reverse Link Overload Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
59/104
Reverse Link Overload Parameter
Reverse Power Control Mode:Value range: 0 ~ 4 Default: 3
Description: Reverse overload control mode.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
60/104
Reverse Link Overload Parameter
RC2/RC3/RC4/RSCH Correction Factor
Value range: 0 ~ 32767
Unit: 1/1000
Description: The equivalent user mode will calculate the
reverse load via converting all reverse service channels
into 8 K voice R-FCH under RC1. This set of
parameters will convert R-FCH of RC1, RC3 and RC4,different target FERs and coding mode (volume or
TURBO) R-SCH into the correction factor for 8 K voice
R-FCH under RC1.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
61/104
Cell Parameter
Cell ParameterSystem Parameter
Power Control Reporting Parameter
Handoff Parameter
Reverse Link Overload Parameter
SCH rate Parameter
Redirect Message Parameters
Link Cell
Neighbor Frequency
ECAM Information Repeat Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
62/104
We can control RSCHrate by setting the
parameters of this table
SCH Rate Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
63/104
Cell Parameter
Cell ParameterSystem Parameter
Power Control Reporting Parameter
Handoff Parameter
Reverse Link Overload Parameter
SCH Rate Parameter
Redirect Message Parameters
Link Cell
Neighbor Frequency
ECAM Information Repeat Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
64/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
65/104
Cell Parameter
Cell ParameterSystem Parameter
Power Control Reporting Parameter
Handoff Parameter
Reverse Link Overload Parameter
SCH Rate Parameter
Redirect Message Parameters
Link Cell
Neighbor Frequency
ECAM Information Repeat Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
66/104
Link Cell
Add neighbor PNAccording to designing .
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
67/104
Cell Parameter
Cell Parameter
System Parameter
Power Control Reporting Parameter
Handoff Parameter
Reverse Link Overload Parameter
RSCH Rate Parameter
Redirect Message Parameters
Link Cell
Neighbor frequency
ECAM Information Repeat Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
68/104
Neighbor frequency
Add neighbor PN forHandoff between carriers .
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
69/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
70/104
ECAM Information Repeat Parameters
We can adjusthow to repeatECAM here.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
71/104
Main Content
BSS Parameters
BTS Parameters
Cell ParametersCarrier Parameters
Channel Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
72/104
Carrier Parameter
Carrier Parameter
Global Redirect Message Parameters
PTT SCH Power Control Parameters
Neighbor Cell List
Access Parameter
Power Control Message Parameter
Forward Power Overload Parameter
Periodic Pilot Measurement Request Order
Traffic Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
73/104
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
74/104
Carrier Parameter
We can use thesetwo parameters
to balance trafficfor multiple
carrier.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
75/104
Carrier Parameter
QPCH support indicator: QPCH_SUPPORTEDValue range: 0: not supported, 1: supportedDefault: 0Description: QPCH is a new control channel in the 1Xsystem compared with the IS95 system, which can onlywork above RC3.
Nominal transmit power offsetValue range: 0~15, corresponding to 8 -~ 7 (db)respectivelyDefault: 0Description: Nominal transmit power offset, expressedin binary supplemental code. This parameter and theparameter Extended nominal transmit power are usedin the open loop power control of reverse links.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
76/104
Carrier Parameter
For carrier handoff
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
77/104
Carrier Parameter
Carrier Parameter
Global Redirect Message Parameters
PTT SCH Power Control Parameters
Neighbor Cell List Access Parameter
Power Control Message Parameter
Forward Power Overload Parameter
Periodic Pilot Measurement Request Order
Traffic Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
78/104
Carrier Parameter
Just default!
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
79/104
Carrier Parameter
Carrier Parameter
Global Redirect Message Parameters
PTT SCH Power Control Parameters
Neighbor Cell List
Access Parameter
Power Control Message Parameter
Forward Power Overload Parameter
Periodic Pilot Measurement Request Order
Traffic Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
80/104
Neighbor Cell List
Attention the relationship withThe cell neighbor list!Carrier neighbor
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
81/104
Carrier Parameter
Carrier Parameter
Global Redirect Message Parameters
PTT SCH Power Control Parameters
Neighbor Cell List
Access Parameter
Power Control Message Parameter
Forward Power Overload Parameter
Periodic Pilot Measurement Request Order
Traffic Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
82/104
Access Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
83/104
A bi
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
84/104
Request Message ready
for transmission
Sequence 2 Sequence 3Access ProbeSequence 1
Access Channel
Request Attempt
Sequence MAX_RSP_SEQ
(15max )
System Time
RS PD RS
Access Probe
1+NUM_STEP
(16 max )
PD PD
Access Probe 3PI
PI
IP
RT TATA RT TA
Select access channel Initial Power
System Time
Access Probe
2Access Probe
1
PD =0 for
ResponseMessage Access Procedure
is depending on the Access parameter .
Access Probing
A P
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
85/104
Access Parameter
NUM_STEP, PWR_STEP and INIT_PWR function simultaneously in the
access attempt sequence of an MS.
INIT_PWR :Initial power offset of access
Unit: dB
Value range: -16 ~ 15 Default: 0
PWR_STEP :Power increment
Unit: dB
Value range: 0 ~ 7 Default: 3
NUM_STEP :Number of access trials
Value range: 0 ~ 15 Default: 6
Description: The maximum number of access probe to be transmitted.
A P
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
86/104
Access Parameter
MAX_CAP_SZUnit: FrameValue range: 0 ~ 7 Default: 3Description: Maximum Access Channel message capsule size. 3 less thanthe maximum number of Access Channel frames in an Access Channelmessage capsule.
PAM_SZUnit: FrameValue range: 0 ~ 15 Default: 3Description:Access Channel preamble length. 1 less than the number of
Access Channel frames that mobile stations are to transmit in each AccessChannel preamble.
A P
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
87/104
Access Parameter
PROBE_BKOFFValue Range: 0~15 Default:0
Description: The next access probe is transmitted after an additional
backoff delay, RT, from 0 to 1+PROBE_BKOFF slots.
RT = 0 ~ [PROBE_BKOFF +1] slots
BKOFF
Value Range: 0~15 Default:0
Description: For every access probe sequence, a backoff delay, RS,from 0 to 1+BKOFF slots is generated pseudorandomly.
RS = 0 ~ [BKOFF +1] slots
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
88/104
C i P t
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
89/104
Carrier Parameter
Carrier Parameter
Global Redirect Message Parameters
PTT SCH Power Control Parameters
Neighbor Cell List
Access Parameter
Power Control Message Parameter
Forward Power Overload Parameter
Periodic Pilot Measurement Request Order
Traffic Parameter
P C t l M g P t
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
90/104
Power Control Message Parameter
Po er Control Message Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
91/104
Power Control Message Parameter
Forward Power Control
Operation Mode Indicator
Value Range: 0~6
Default:0
Description: Indication
of forward power control
operation mode of F-
FCH where there is no
F-SCH.
Carrier Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
92/104
Carrier Parameter
Carrier Parameter
Global Redirect Message Parameters
PTT SCH Power Control Parameters
Neighbor Cell List
Access Parameter
Power Control Message Parameter
Forward Power Overload Parameter
Periodic Pilot Measurement Request Order
Traffic Parameter
Forward Power Overload Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
93/104
Forward Power Overload Parameter
Forward Power Overload Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
94/104
Forward Power Overload Parameter
Rating Power: RATING_PWR Unit: Milliwatt
Value: 0~30000
Description: The parameter refers to the rated power of HPA ,
Provided by network planning .
Cell Power design value: CELL_PWR
Unit: Milliwatt
Value: 0~30000
Description: Designed power of the cell.
Carrier Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
95/104
Carrier Parameter
Carrier Parameter
Global Redirect Message Parameters
PTT SCH Power Control Parameters
Neighbor Cell List
Access Parameter
Power Control Message Parameter
Forward Power Overload Parameter
Periodic Pilot Measurement Request Order
Traffic Parameter
Periodic Pilot Measurement Request Order
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
96/104
For carrier handoff
Periodic Pilot Measurement Request Order
Carrier Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
97/104
Carrier Parameter
Carrier Parameter
Global Redirect Message Parameters
PTT SCH Power Control Parameters
Neighbor Cell List
Access Parameter
Power Control Message Parameter
Forward Power Overload Parameter
Periodic Pilot Measurement Request Order
Traffic Parameter
Traffic Parameter
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
98/104
Traffic Parameter
CE search window
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
99/104
Main Content
BSS Parameters
BTS Parameters
Cell ParametersCarrier Parameters
Channel Parameters
Channel Parameters
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
100/104
Channel Parameters
Pilot Channel
Synchronous Channel
Paging Channel
Access Channel
Configuring Pilot Channel
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
101/104
Configuring Pilot Channel
Configuring Pilot Channel
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
102/104
Configuring Pilot Channel
ModuleIdValue range:
Default: 1
Description: Module where the Pliot channel is located,The
parameter has influence upon cell coverage.
ElementId
Value range: 0 ~ 35
Default: 0
Description: Element where the pilot channel is located. The
parameter has influence upon cell coverage.
Pilot channel gain
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
103/104
40255INPILOTCH_GA
10 _
PWR CELLmW PilotPower
Pilot channel gain
Unit: (X-255)/4
Value range: 0 ~ 255 Default: 225Description : Provided by network planning, generallyaccording to the default value.Suppose the configuration value is X, the corresponding dBvalue is (x- 255)/4. For example, if Pilot_gain is set to 225, the
corresponding dB value is (225-255)/4 = -7.5dB.
The Synchronous Channel, Paging Channel and AccessChannel are similar to this.
8/10/2019 27 OMC-Radio-Parameters-104-ok.ppt
104/104