565

Click here to load reader

2012 Powerwave Product Catalog

Embed Size (px)

Citation preview

P R O D U C T

C A T A L O G

J A N U A R Y

2 0 1 2

Table of Contents

POWERWAVE

Table of Contents

Page Base Station Products and Solutions Power Amplifier Solutions MCPA Modules Single MCPA Outdoor Booster Systems Dual MCPA Outdoor Booster Systems Triple MCPA Outdoor Booster Systems TMA Products Tower Mounted Amplifiers Power Distribution Unit Current Injectors Filters Diplexer/Crossband Combiners Duplexers Same Band Combiners T1 Triplexer/Crossband Combiners Interference Filters RMDU and Enclosure Solutions MicroFlex Outdoor Enclosures RapidFlex Outdoor Enclosures SubTerra Controlled Environment Vault VersaFlex Shelter Solutions Coverage Products and Solutions Repeater Products Channel Selective Standard Repeaters Band Selective Compact Repeaters Band Selective Standard Repeaters Advanced Train Repeaters Digital Repeaters In-Building and Outdoor DAS Products Repeater Products Bi-Directional Amplifiers Fiber Optic DAS Master Unit LinkNet Convergence Platform Tap-In Signal Distribution Taps Nexus FT Public Safety DAS Products Wide Band Radio Heads Nexus FT Single and Dual Band Nexus FT Rack Mounts Repeater Remote Management Products Base Station Management Interface IP/SNMP/GPS Repeater Remote Management Interface Antenna Products Broadband Antennas Single Broadband Antennas Cross Polarized High Broadband Cross Polarized Antennas, 1710-2170 MHz Low Broadband Cross Polarized Antennas, 806-960 MHz Low Broadband Cross Polarized Antennas, 698-894 MHz Dual Broadband Antennas Dual High Broadband Cross Polarized Antennas, 2x1710-2170 MHz Dual High Broadband Cross Polarized Antennas, 824-960/1710-2170 MHz Triple Broadband Antennas Cross Polarized Triple Broadband Cross Polarized Antennas, 824-960/2x1710-2170 MHz

6 14 20 24 31 68 72 79 85 86 90 91 95 98 100 102

108 138 170 185 190

203 206 208 216 218 220 223 259 265 267

274 305 343 351 361

368

1

Table of Contents

POWERWAVE

Table of Contents

Page Triple Broadband Cross Polarized Antennas, 790-960/1710-2170/2500-2690 MHz Single and Dual Band Antennas Single Band Antennas Cross Polarized ALX Cross Polarized Antennas, 806-896 MHz X-Urban Cross Polarized Antennas, 824-896/870-960 MHz Vertical Polarized Omni Vertical Polarized Antennas, 806-896 MHz Urban Vertical Polarized Antennas, 824-896/870-960 MHz Dual Band Antennas Vertical Polarized ALVC Vertical Polarized Antennas, 806-896/1850-1990 MHz iRET Low Broadband Cross Polarized iRET Antennas, 698-894MHz Dual Broadband Cross Polarized iRET Antennas, 698-894/1710-2170MHz Triple High Broadband Cross Polarized iRET Antennas, 1710-2170 MHz High Broadband Cross Polarized iRET Antennas, 1710-2170 MHz Dual High Broadband Cross Polarized iRET Antennas, 1710-2170 MHz Dual High Broadband Cross Polarized iRET Antennas, 1710-2170/2300-2700 MHz Dual High Broadband Cross Polarized iRET Antennas, 2300-2700 MHz iDiplexer Antennas Multi Broadband Cross Polarized Antennas Remote Electrical Tilt (RET) Single Band RET Dual Band RET Triple Band RET iRET Antenna Controller Module 8510 Master Control Unit Current Injector Layer One Converter RET System Cables Indoor Antennas Dual Band Indoor Antennas Cross Polarized Indoor Dual Band Cross Polarized Antennas, 824-896/1850-1990 MHz Multiband Indoor Antennas Vertical Polarized Indoor Multiband Vertical Polarized Antennas, 800-2500 MHz Clean Site Solutions Mounting Solutions Antenna FAQ Network Management Part Number Index 375

384 386 406 414

438 452 456 463 483 489 493 496 502 508 517 520 523 526 533 538

543

545 549 551 558 559 561

2

Base Station Products

Power wave

Base Station ProductsA unique combination of capabilities sets Powerwave apart from other providers when it comes to rapidly delivering cost-effective base station solutions to operators & OEMs. From straightforward crossband and same band combiners to active multi-function assemblies such as tunable combiners, active same band combiners and integrated amplifier assemblies, Powerwave has you covered.

Power Amplifier Solutions TMA Products Filters

Comprehensive RF/Digital CompetenciesOur engineering staff has expertise across all facets of RF and digital signal processing. Using all of these technological competencies, we are able to create highly integrated performance and cost-effective base station solutions. Higher integration means fewer parts, optimum manufacturing efficiency and better value.

End-to-End System ProviderBecause Powerwave is a proven provider for all categories of wireless infrastructure solutions - from antenna products to base station products to coverage products - you can rely on us as a value-added single-source to consolidate and streamline your supply chain.

Base Station Products

POWERWAVE

Base Station Products

Power Amplifier Solutions MCPA Modules Single MCPA Outdoor Booster Systems Dual MCPA Outdoor Booster Systems Triple MCPA Outdoor Booster Systems TMA Products Tower Mounted Amplifiers Power Distribution Units Current Injectors Filters Diplexer/Crossband Combiners Duplexers Same Band Combiners T1 Triplexer/Crossband Combiners Interference Filters

Page

6 14 20 24

31 68 72

79 85 86 90 91

4

Power Amplifier Solutions

Power wave

Powerwave offers one of the industrys largest and most diverse line of power amplifier systems for cellular, EGSM, DCS, PCS, AWS and UMTS wireless networks, with more than 350,000 MCPAs and SCPAs deployed worldwide. One key reason for this success is that we are able to rapidly roll out new solutions by leveraging the modular architecture of existing systems. Building upon field-proven products and technologies, our RF engineers are able to shorten design time and deliver systems with industryleading efficiency, packaging density and reliability to help service providers reduce both operating and capital expenses within their network while increasing revenues.

MCPA Modules Single MCPA Outdoor Booster Systems Dual MCPA Outdoor Booster Systems Triple MCPA Outdoor Booster Systems

Base Station Products

POWERWAVE

MCPA Modules

Power Amplifier SolutionsMCPA Modules

Title 180W Multi-Carrier Power Amplifier 160W Multi-Carrier Power Amplifier 135W Multi-Carrier Power Amplifier 120W Multi-Carrier Power Amplifier 170W Multi-Carrier Power Amplifier 140W Multi-carrier Power Amplifier

Range (MHz) 850

Air Interface GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA

Part Number G3l-850-180

Page 7

850

G3L-850-160

9

900

G3L-929-135

10

1800

G3L-1829-120

11

1900

G3L-1929-160

12

2100

G3L-2129-140

13

6

G3L-850-180Introduction:The G3L-850-180 is a high performance Multi-Carrier Power Amplifier (MCPA) intended for Cellular applications. This PA utilizes Powerwaves feed-forward linearization technique to provide maximum operating BW and compatibility with 2G, 3G and 4G air interface standards. Latest generation devices and biasing schemes provide industry leading efficiency, RF output power and spectrum performance allowing significant savings in OPEX and CAPEX.

Multi-Carrier Power Amplifiers

Features:q

Automatic Power Control (APC) @ 210W Phase matched for parallel combining Internal monitoring and alarming for VSWR, linearization, voltage, overpower Backward compatible with legacy MCPA systems Common form-factor with PCS and AWS models

q

q

q

q

ELECTRICAL SPECIFICATIONSFrequency Range (MHz) Bandwidth (MHz) Instantaneous Bandwidth (MHz) Air Interface Efficiency RF Output Power Intermodulation Distortion Harmonics Nominal RF Gain (dB) Gain Flatness Gain Variation with Temperature Input Return Loss Output Return Loss DC Input Voltage Range (DC) DC Input Current Alarms and Protections 869 ~ 894 25 25 GSM, EDGE, CDMA2000, WCDMA, LTE 23% 180W FCC & Air Interface Compliant -13dBm/1MHz 63dB +/-0.5dB +/-0.5dB 14dB 16dB +22V ~ + 30V 29A @ +27V, 180W RF Ouput VSWR, Temp, Overpower, PSU, Linearization

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

Page 1 of 2 Updated: Oct 5 2011 5:41PM

Powerwave Technologies 1801 East St. Andrew Place, Santa Ana, CA 92705 USA Tel: 714-466-1000 Fax: 714-466-5800 www.powerwave.com [email protected]

7

G3L-850-180MECHANICAL SPECIFICATIONSDimension HxWxD, ft. (mm) Weight, lbs (kg) Connectors DC Terminal Post Connectors RF Input Connectors RF Output Connectors Alarm Output Serial Interface (GUI)

Multi-Carrier Power Amplifiers

12 x 4 x 16 (354.6 x 95.6 x 450) 24.3 (11.0) PDM (D-Sub 17/21 Blind Mate) PKZ (D-Sub 17/21 Blind Mate) PKZ (D-Sub 17/21 Blind Mate) D-Sub 17/21 Blind Mate RJ-11 Jack

ENVIRONMENTAL SPECIFICATIONSOperating Temperature Range Storage Temperature Range Operating Humidity Storage Humidity -20oC ~ +50oC -40oC ~ +70oC 5% ~ 80% RH 5% ~ 95% RH

Example Performance @ 180W RF Output

Single Carrier HSPA+ PCDE Compliant Peak EVM Compliant

Multi-Carrier HSPA+ PCDE Compliant Peak EVM Compliant

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

Page 2 of 2 Updated: Oct 5 2011 5:41PM

Powerwave Technologies 1801 East St. Andrew Place, Santa Ana, CA 92705 USA Tel: 714-466-1000 Fax: 714-466-5800 www.powerwave.com [email protected]

8

POWERWAVE

Multi-Carrier Power Amplifiers

G3L-850-160

160W Multi-Carrier Power Amplifier

ELECTRICAL SPECIFICATIONS* Band (MHz) Frequency Range (MHz) Instantaneous Bandwidth Air Interface Efficiency RF Output Power Intermodulation Distortion Harmonics Nominal RF Gain (dB) Gain Flatness Gain Variation with Temperature Input Return Loss Output Return Loss DC Input Voltage Range DC Input Current Alarms and Protections 850 869-894 25 GSM/EDGE/CDMA2000/WCDMA 18% 160W (Typical) -65 dBc Better than -13 dBm/ 1MHz 63 dB 0.5 dB 0.5 dB +/-0.5 dB 16 dB (Max) 16 dB (Max) 26 to 28 Vdc (+21 to 30 Vdc Operational) Typical: 30.5A (GSM), 29 (CDMA) Input over power, VSWR, DC failure, High temperature, Loop failure

MECHANICAL SPECIFICATIONS* Dimension HxWxD, mm(ft) Weight(lbs) Connectors DC Terminal Post Connectors RF Input Connectors RF Output Connectors Alarm Output 355 x 99 x 450 (12x4x16) 24.3 N/A Sub-miniature Combo D connector for RF & Digital interfaces N/A N/A

ENVIRONMENTAL SPECIFICATIONS* Operating Temperature Range Storage Temperature Range Operating Humidity Storage Humidity -33 C to 50 C -40 to 70 C 0% to 80% (non condensing) 0% to 95% (non condensing)

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Updated: Dec 5 2010 4:38PM

9

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Multi-Carrier Power Amplifiers

G3L-929-135

135W Multi-Carrier Power Amplifier

ELECTRICAL SPECIFICATIONS* Band (MHz) Frequency Range (MHz) Instantaneous Bandwidth Air Interface Efficiency RF Output Power Intermodulation Distortion Harmonics Nominal RF Gain (dB) Gain Flatness Gain Variation with Temperature Input Return Loss Output Return Loss DC Input Voltage Range DC Input Current Alarms and Protections 900 925-960 MHz 25 MHz GSM/EDGE/CDMA2000/WCDMA 19% 135W (Typical) -65 dBc (Typical) Better than -13 dBm/1 MHz 63 dB 0.5 dB 0.5 dB 0.5 dB 14 dB (Max) 16 dB (Max) 26 to 28 Vdc (21 to 30 Vdc Operational) 26A (nominal at rated power) Input over drive, VSWR, DC failure, High temperature, Loop failure, APC

MECHANICAL SPECIFICATIONS* Dimension HxWxD, mm(ft) Weight(lbs) Connectors DC Terminal Post Connectors RF Input Connectors RF Output Connectors Alarm Output 355 x 99 x 450 (12x4x16) 20 21W4 Combo-D w/size 8 contact 21W4 Combo-D w/PkZ contact 21W4 Combo-D w/PkZ contact 21W4 combo-D

ENVIRONMENTAL SPECIFICATIONS* Operating Temperature Range Storage Temperature Range Operating Humidity Storage Humidity -33 C to 50 C -40 C to 70 C 5% to 95% non-condensing 5% ro 95% non-condensing

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Updated: Dec 6 2010 5:44PM

10

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Multi-Carrier Power Amplifiers

G3L-1829-120

120W Multi-Carrier Power Amplifier

ELECTRICAL SPECIFICATIONS* Band (MHz) Frequency Range (MHz) Instantaneous Bandwidth Air Interface Efficiency RF Output Power Intermodulation Distortion Harmonics Nominal RF Gain (dB) Gain Flatness Gain Variation with Temperature Input Return Loss Output Return Loss DC Input Voltage Range DC Input Current Alarms and Protections 1800 1805-1880 35 GSM/EDGE/CDMA2000/WCDMA 13.4% (GSM) Typical: 120W -65 dBc (Typical) Better than -13 dBm/ 1MHz 63 dB +/- 0.5 +/-0.3 dB +/-0.5 dB 17 dB (Max) 18 dB (Max) 26 to 30 /Vdc (22 to 30 Vdc Operational) Typical: 33A (GSM), 31A (CDMA) Input over drive, VSWR, DC failure, High temperature, Loop failure, APC

MECHANICAL SPECIFICATIONS* Dimension HxWxD, mm(ft) Weight(lbs) Connectors DC Terminal Post Connectors RF Input Connectors RF Output Connectors Alarm Output 355 x 99 x 450 (12x4x16) 23 21W4 Combo-D w/size 8 contact 21W4 Combo-D w/PkZ contact 21W4 Combo-D w/PkZ contact 21W4 Combo-D

ENVIRONMENTAL SPECIFICATIONS* Operating Temperature Range Storage Temperature Range Operating Humidity Storage Humidity -33 C to 50 C -40 to 70 C 5% to 95% (non condensing) 5% to 95% (non condensing)

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Updated: Dec 5 2010 4:39PM

11

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Multi-Carrier Power Amplifiers

G3L-1929-160

170W Multi-Carrier Power Amplifier

ELECTRICAL SPECIFICATIONS* Band (MHz) Frequency Range (MHz) Instantaneous Bandwidth Air Interface Efficiency RF Output Power Intermodulation Distortion Harmonics Nominal RF Gain (dB) Gain Flatness Gain Variation with Temperature Input Return Loss Output Return Loss DC Input Voltage Range DC Input Current Alarms and Protections PCS 1930-1995 Up to 65 GSM/EDGE/CDMA2000/WCDMA 18.5% 170 Watts (Typical) -65 dBc Better than -13 dBm/ 1MHz 63 dB 0.5 dB 0.5 dB +/-0.5 dB 16 dB (Max) 16 dB (Max) 26 to 28 Vdc (+21 to 30 Vdc Operational) 34A@170W, 33A@160W Input over power, VSWR, DC failure, High temperature, Loop failure

MECHANICAL SPECIFICATIONS* Dimension HxWxD, mm(ft) Weight(lbs) Connectors DC Terminal Post Connectors RF Input Connectors RF Output Connectors Alarm Output 355 x 99 x 450 (12x4x16) 26.4 N/A Sub-miniature Combo D connector for RF & Digital interfaces N/A N/A

ENVIRONMENTAL SPECIFICATIONS* Operating Temperature Range Storage Temperature Range Operating Humidity Storage Humidity -33 C to 50 C -40 to 70 C 0% to 80% (non condensing) 0% to 95% (non condensing)

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Updated: Dec 5 2010 4:42PM

12

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Multi-Carrier Power Amplifiers

G3L-2129-140

140W Multi-carrier Power Amplifier

ELECTRICAL SPECIFICATIONS* Band (MHz) Frequency Range (MHz) Instantaneous Bandwidth Air Interface Efficiency RF Output Power Intermodulation Distortion Harmonics Nominal RF Gain (dB) Gain Flatness Gain Variation with Temperature Input Return Loss Output Return Loss DC Input Voltage Range DC Input Current Alarms and Protections 2100 2110-2170 60 MHz CDMA2000/WCDMA/LTE > 15% (45 MHz IBW), >14% (60 MHz IBW) 140W Spurious Emissions - 3GPP TS25.141 Air interface compliant. -13 dBm (Max.) 1 MHz Bandwidth; -50 dBc (Max.) 63 dB +/-0.5 dB +/-0.5 dB 14 16 +26 to +28 Vdc Nominal (+21 to +30 Operational) 34.5A (Nominal, at 27V, 140W output) Input over drive, VSWR, DC failure, High temperature, Loop failure

MECHANICAL SPECIFICATIONS* Dimension HxWxD, mm(ft) Weight(lbs) Connectors DC Terminal Post Connectors RF Input Connectors RF Output Connectors Alarm Output 355 x 99 x 500 (incl handles) (13.96 H X 3.9 W X 19.7 D) 28.5 21W4 Combo-D w/size 8 contact 21W4 Combo-D w/PkZ contact 21W4 Combo-D w/PkZ contact 21W4 Combo-D

ENVIRONMENTAL SPECIFICATIONS* Operating Temperature Range Storage Temperature Range Operating Humidity Storage Humidity -20 C to +50 C -40 to +85 C 5% to 90% (non condensing) 5% to 90% (non condensing)

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Updated: Dec 5 2010 4:44PM

13

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

Base Station Products

POWERWAVE

Single MCPA Outdoor Booster Systems

Power Amplifier SolutionsSingle MCPA Outdoor Booster Systems

Title OS-1 Outdoor System

Range (MHz) 800

Air Interface GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA

Part Number OS-0851-P0-XXX

Page 15

OS-1 Outdoor System

900

OS-0951-P0-XXX

16

OS-1 Outdoor System

1800

OS-1851-H0-XXX

17

OS-1 Outdoor System

1900

OS-1951-E0-XXX

18

OS-1 Outdoor System

2100

OS-2151-E0-XXX

19

14

POWERWAVE

Outdoor Booster Systems

OS-0851-P0-XXX

OS-1 Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM/EDGE/CDMA/WCDMA 869-894 824-849 120** -65* dBc 25 0 to +20 2.5* (-000 version) 180-264 VAC or +27VDC 2.5 @ max gain, 3.0 @ min gain* (-003 version) 0 to +13.0 variable (-003 version) +12 min (-003 Version) 100 min 7.0 (+/- 2 dB) (-003 version) 15 min 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 228 X 660 X 660 (9x 22 x 22) 102 7/16 DIN female X 6 1 1

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -20 C to +50 C IP54 20kA EIC 61000-4-5, 8/20us waveform

ORDERING INFORMATION Model Number 930-00018-009 (optional) MCPA Modules: G3L-850-160 160W MCPA Module 1 Description 3 KW Rectifier Quantity 1

Choose one of the following Enclosures: OS-0851-P0-000 OS-0851-P0-003 Enclosure -TMA model Enclosure - LNA model with VSWR monitor 1 1

* Typical Performance. ** Typical, with G3L-850-160 MCPA Module Inserted.All specifications are subject to change without notice. Contact your Powerwave representative for complete performance data.

Updated: Aug 26 2010 12:04PM

15

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Outdoor Booster Systems

OS-0951-P0-XXX

OS-1 Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM/EDGE/WCDMA 925-960 880-915 105 Watts** Spurious Emissions - 3GPP TS45.005 & TS25.141 Air Interface Compliant 35 0 to +20.0 variable 2 dB* (-100 model) 94-264 VAC (Single Phase) or +27VDC 2.5* @ max. gain, 3.5* @ min. gain (-103 version) 0 to +14.0 variable (-100 model) > 0 dBm 100 min. 0-10 dB output RL 14 min. 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 620 X 284 X 716 (24.4x 11.18 x 28.18) 50 Kg (110 lbs) 7/16 DIN Female X 4 1 1

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -30 to +50 IP54 40kA per line, 8/20 us waveform

ORDERING INFORMATION Model Number Choose one enclosure: OS-0951-P0-104 OS-0951-P0-103 Amplifier Module: G3L-929-135 135W MCPA Module 1 1 sector, with LNA, includes rectifier and modem 1 sector, with LNA, includes rectifier 1 1 Description Quantity

* Typical Performance. ** Typical, with G3L-929-135 MCPA Module Inserted.All specifications are subject to change without notice. Contact your Powerwave representative for complete performance data.

Updated: Feb 11 2011 10:24AM

16

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Outdoor Booster Systems

OS-1851-H0-XXX

OS-1 Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) 15 min. 50 GSM/EDGE/CDMA/WCDMA 1805-1880 1710-1785 90** Watts -65* dBc 45 0 to +14 2dB* (-000 version) 94-264 VAC (Single Phase, 47-63Hz) or +27VDC 2.3* @ max. Gain, 1.89* @ min. Gain 0 to +13.0 variable (-003 version) +12 min. 100 min.

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 610 X 284 X 716 (24x 11 x 28) 102 7/16 DIN Female X 6 1 1

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -20 C to +50 C IP54 20kA EIC 61000-4-5, 8/20 us waveform

ORDERING INFORMATION Model Number G3L-1829-120 Description 120W MCPA module Quantity 1 1 Choose one of: OS-1851-H0-000 OS-1851-H0-003 Enclosure - TMA model - DC transparency Enclosure - LNA model - includes VSWR monitor, lightning arrestors 1 1

* Typical Performance. ** Typical, with G3L-1829-120 MCPA Module Inserted.All specifications are subject to change without notice. Contact your Powerwave representative for complete performance data.

Updated: Jun 10 2010 2:32PM

17

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Outdoor Booster Systems

OS-1951-E0-XXX

OS-1 Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM, EDGE,CDMA,WCDMA 1930-1990 1850-1910 125** Watts -65 dBc 65 0 to +20 variable 2 dB (-100 series) 94-264 VAC (Single Phase, 47-63 Hz), or +27 VDC 2.5 dB max (all models except -100) 0 to +14 dB (all models except -100) > 0 dBm 100 dB min 0-10 dB output RL 14 dB min 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 620 X 284 X 716 (24.4x 11.18 x 28.18) 110 (50 Kg) 7/16 DIN Female X 6 1 1

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -30 C to +50 C IP54 40 KA per line, 8/20 us WF

ORDERING INFORMATION Model Number Enclosures (Select one): OS-1951-E0-102 MCPA Module G3L-1929-160 Alternatively, select a Kit: INST-OS-1951-103 Kit includes: G3L-1929-160 amplifier module OS-1951-E0-102 enclosure 1 1 160W 1900 MHz MCPA 1 1 sector, with LNA, includes rectifier 1 Description Quantity

* Typical Performance** Typical, with G3L-1929-160 inserted, 45 MHz IBWAll specifications are subject to change without notice. Contact your Powerwave representative for complete performance data.

Updated: Jul 20 2010 3:04PM

18

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Outdoor Booster Systems

OS-2151-E0-XXX

OS-1 Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM,EDGE,CDMA,WCDMA 2110-2155 (AWS, -4XX series), 2110-2170 (UMTS, -1XX series) 1710-1755 (AWS, -4XX series), 1920-1980 (UMTS, -1XX series) 100W** Spurious Emissions - 3GPP TS25.141 Air interface compliant. 45 (AWS, -4XX series) 60 (UMTS,-1XX series) 0 to +20 variable 2 dB (-100,-400 models) 94-264 VAC (Single Phase, 47-63 Hz), or +27 VDC 2.5 dB max (-101,-401 models) 0 to +14 dB adjustable (-101,-401 models) >0 dBm 100dB min. 0-10 dB output RL (selectable) 14 dB min. 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 620 X 284 X 716 (24.4x 11.18 x 28.18) 110 (50 Kg) 7/16 DIN Female X 4 1 1

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -30 C to +50 C IP54 40kA per line, 8/20 us WF

ORDERING INFORMATION Model Number Enclosures (select one) OS-2151-E0-101 OS-2151-E0-104 OS-2151-E0-401 OS-2151-E0-404 MCPA Module: G3L-2129-140 140W MCPA module 1 LNA model - UMTS (Band Class 1) w/rectifier LNA model - UMTS (Band Class 1) w/rectifier and modem LNA model - AWS (Band Class 4) w/rectifier LNA model - AWS (Band Class 4) w/rectifier and modem 1 1 1 1 Description Quantity

Updated: Jul 20 2010 3:26PM

19

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

Base Station Products

POWERWAVE

Dual MCPA Outdoor Booster Systems

Power Amplifier SolutionsDual MCPA Outdoor Booster Systems

Title OS-2 Outdoor System

Range (MHz) 900

Air Interface GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA

Part Number OS-0921-V0-XXX

Page 21

OS-2 Outdoor System

1800

OS-1821-H0-XXX

22

OS-2 Outdoor System

1900

OS-1921-H0-XXX

23

20

POWERWAVE

Outdoor Booster Systems

OS-0921-V0-XXX

OS-2 Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) EGSM/EDGE 925-960 880-915 180** Watts -65* dBc 25 1 MCPA Module 0 to 17.5, 2 MCPA Module 0 to 20.5 2dB*(-000 variant), 0.5dB*dB (bypass mode) 180-264 VAC, 47-63 Hz Single Phase, or +27VDC 2.5* @ max. Gain, 3.5* @ min. Gain (-001 and -003 variants) 0 to +11.0 variable (-001 and -003 variants) +12 min. 90 min. 9.5 (+/-2dB) (-003 variant) 14 min. 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 407 x 865 x 840 (14x 210x 29) 151-183 7/16 DIN Female X 4 1 or 2 1

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -20 to +50 IP54 20kA EIC 61000-4-5, 8/20 us waveform

ORDERING INFORMATION Model Number G3L-929-135 1001308 Choose one of the following Enclosures: OS-0921-V0-010 OS-0921-V0-011 OS-0921-V0-013 Enclosure - TMA model - 12V supply to TMA Enclosure - LNA model Enclosure - LNA model with VSWR monitor 1 1 1 Description 135W MCPA module Rectifier Quantity 1-2 2-3

Updated: Jun 10 2010 2:33PM

21

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Outdoor Booster Systems

OS-1821-H0-XXX

OS-2 Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM/EDGE 1805-1880 1710-1785 160** Watts -65* dBc 35 1 MCPA Module 0 to +12, 2 MCPA Module 0 to +15 2.5dB*, 0.5dB* (bypass) 180-264 VAC, 47-63 Hz Single Phase, or +27VDC 2.5* @ max. Gain, 3.5* @ min. Gain (-001 version) 0 to +12.0 variable (-001 version) +12dBm min. 100 min. N/A 14 min 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 407 x 865 x 840 (14x 210x 29) 151-183 7/16 DIN Female X 4 2 1

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -20 C to +50 C IP54 20kA EIC 61000-4-5, 8/20 us waveform

ORDERING INFORMATION Model Number G3L-1829-120 1001308 Choose one of the following Enclosures: OS-1821-H0-004 OS-1821-H0-005 TMA Model - 12VDC supply to TMA LNA Model 1 1 Description 120W MCPA Module AC Rectifier Quantity 1-2 2-3

* Typical ** Typical, with two G3L-1829-120 modules installed. All specifications are subject to change without notice. Contact your Powerwave representative for complete performance data.

Updated: Jun 10 2010 2:32PM

22

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Outdoor Booster Systems

OS-1921-H0-XXX

OS-2 Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM/EDGE/CDMA/WCDMA 1930-1990 1850-1910 160** Watts -65* dBc 45/60 1 MCPA Module 0 to +12, 2 MCPA Modules 0 to +15 2.5* 180-264 VAC, 47-63 Hz Single Phase, or +27VDC N/A N/A N/A 100 dB min N/A 14dB min. 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 407 x 863 x 838 (16x 34x 33) 151-183 7/16 DIN Female X 8 2 1

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -20 C to +50 C IP54 20kA EIC 61000-4-5, 8/20 us waveform

ORDERING INFORMATION Model Number 930-00018-009 OS-1921-H0-000 Description 3 KW rectifier Enclosure - TMA model - DC transparency or TMA bias Function (configurable) Compatible with MCPA Module: G3L-1929-120 120W MCPA module 1-2 Quantity 1-2 1

* Typical ** Typical, output power at antenna port with 2 G3L-1929-120 modules installed, 45 MHz IBW. All specifications are subject to change without notice. Contact your Powerwave representative for complete performance data.

Updated: Jun 10 2010 2:33PM

23

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

Base Station Products

POWERWAVE

Triple MCPA Outdoor Booster Systems

Power Amplifier SolutionsTriple MCPA Outdoor Booster Systems

Title OS-3 3 Sector Outdoor System OS-3 3 Sector Outdoor System OS-3 3 Sector Outdoor System OS-3 Outdoor System OS-3 3 Sector Outdoor System

Range (MHz) 900

Air Interface GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA GSM/EDGE/CDMA2000/ WCDMA

Part Number OS-0933-E0-XXX

Page 25

1800

OS-1833-E0-XXX

26

1900

OS-1933-E0-XXX

27

1900

OS-1991-H0-XXX

28

2100

OS-2133-E0-XXX

29

24

POWERWAVE

Outdoor Booster Systems

OS-0933-E0-XXX

OS-3 3 Sector Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM/EDGE/CDMA/WCDMA 925-960 880-915 110 W* -63 dBc* 35 (with G3L-929-135 module) 0-17 Variable 0.5dB* (RF Bypass Mode) 180-264 VAC, -48VDC (-103 model) 2.5 (Max @ 12dB Gain), 4.5 (Max @ 0 dB gain) 0-12 dB 0.0 100 Adjustable 14 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 16 W x 40 H x 38 D 385 (175 kg) 7/16 DIN-F, N-F 1 3

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -20 C to +50 C IP55 20kA EIC 61000-4-5, 8/20 uS Waveform

ORDERING INFORMATION Model Number OS-0933-E0-003 Description OS-3, 900 MHz, Trident 3 Sector, 3I/3O Includes: G3L-929-135 modules RF Conditioning Units (RFCU) 220VAC Rectifiers OS-0933-E0-103 -48VDC version of OS-0933-E0-003 Includes four -48VDC rectifiers instead of 220VAC rectifiers OS-0933-E0-001 OS-3, 900 MHz, Trident 1 Sector, 3I/3O Includes: G3L-929-135 module RF Conditioning Unit (RFCU) 220VAC Rectifiers INST-0933-E0-001 1 Sector Upgrade Kit Includes: G3L-929-135 module RF Conditioning Unit (RFCU) 220VAC Rectifier 1 1 1 1 1 1 2 Quantity 1 3 3 4

Updated: Sep 6 2011 10:20AM

25

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Outdoor Booster Systems

OS-1833-E0-XXX

OS-3 3 Sector Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM/EDGE/CDMA/WCDMA 1805-1880 1710-1785 100 W* -63 dBc* 75 (with G3L-1829-120 module) 0-17 Variable 0.5dB* (RF Bypass Mode) 180-264 VAC, -48VDC (-103 model) 2.5 (Max @ 12dB Gain), 4.5 (Max @ 0 dB gain) 0-12 dB 0.0 100 Adjustable 14 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 16 W x 40 H x 38 D 385 (175 kg) 7/16 DIN-F, N-F 1 3

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -20 C to +50 C IP55 20kA EIC 61000-4-5, 8/20 uS Waveform

ORDERING INFORMATION Model Number OS-1833-E0-003 Description OS-3, 1800 MHz, Trident 3 Sector, 3I/3O Includes: G3L-1829-120 modules RF Conditioning Units (RFCU) 220VAC Rectifiers OS-1833-E0-103 -48VDC version of OS-1833-E0-003 Includes four -48VDC rectifiers instead of 220VAC rectifiers OS-1833-E0-001 OS-3, 1800 MHz, Trident 1 Sector, 3I/3O Includes: G3L-1829-120 module RF Conditioning Unit (RFCU) 220VAC Rectifiers INST-1833-E0-001 1 Sector Upgrade Kit Includes: G3L-1829-120 module RF Conditioning Unit (RFCU) 220VAC Rectifier 1 1 1 1 1 1 2 Quantity 1 3 3 4

Updated: Sep 16 2011 1:03PM

26

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Outdoor Booster Systems

OS-1933-E0-XXX

OS-3 3 Sector Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM/EDGE/CDMA2000/WCDMA 1930-1995 1850-1915 150W* -65 dBc* 65 (with G3L-1929-160 module) 0-17 Variable 0.5dB* (RF Bypass Mode) 180-264 VAC, -48VDC (-103 model) 2.5 (Max @ 12dB Gain), 4.5 (Max @ 0 dB gain)* 0-12 dB 0.0 100 Adjustable 14 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 16 W x 40 H x 38 D 385 (175 kg) 7/16 DIN-F, N-F 1 3

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -20 C to +50 C IP55 20kA EIC 61000-4-5, 8/20 uS Waveform

ORDERING INFORMATION Model Number OS-1933-E0-003 Description OS-3, 1900 MHz, Trident 3 Sector, 3I/3O Includes: G3L-1929-160 modules RF Conditioning Units (RFCU) 220VAC Rectifiers OS-1933-E0-103 -48VDC version of OS-1933-E0-003 Includes four -48VDC rectifiers instead of 220VAC rectifiers OS-1933-E0-001 OS-3, 1900 MHz, Trident 1 Sector, 3I/3O Includes: G3L-1929-160 module RF Conditioning Unit (RFCU) 220VAC Rectifiers INST-1933-E0-001 1 Sector Upgrade Kit Includes: G3L-1929-160 module RF Conditioning Unit (RFCU) 220VAC Rectifier 1 1 1 1 1 1 2 Quantity 1 3 3 4

Updated: Jan 25 2011 4:27PM

27

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Outdoor Booster Systems

OS-1991-H0-XXX

OS-3 Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM/EDGE/CDMA2000/WCDMA 1930-1995 1850-1915 335** Watts -65* dBc 45/65 duplex/simplex: 3 MCPAs: 0.0 to +16.2/17.0, 2 MCPAs: 0 to 14.4/15.2, 1 MCPA: 0 to +11.4/12.2 3.0 max (-003, -103, -200 versions) -36 to -60VDC (-103 version), 180-264VAC (-003,-004 versions),+26-28VDC (-200 version) 2.5 at max Rx gain (-004 version) 0-12 dB in 1 dB increments (-004 version only) 0.0 (-004 version only) 100 min N/A 14 min. 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 405 x 774 x 864 (14x 26x 210) 255 lbs, fully populated, with 3 MCPA modules 7/16 DIN Female 3 1

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -20 C to +50 C IP55 20kA EIC 61000-4-5, 8/20 us waveform

ORDERING INFORMATION Model Number Choose one of: G3L-1929-160 G3L-1929-120 Choose one of: OS-1991-H0-003 OS-1991-H0-004 OS-1991-H0-103 OS-1991-H0-200 220 VAC Enclosure - TMA model 220 VAC Enclosure - LNA with DC bypass option for TMA bias -48 VDC Enclosure - TMA model +27 VDC Enclosure - TMA model 1 1 1 1 160W MCPA module 120W MCPA module 1-3 1-3 Description Quantity

* Typical performance**Typical, with 3 G3L-1929-160 modules, 45 MHz IBW.All specifications are subject to change without notice. Contact your Powerwave representative for complete performance data.

Updated: Dec 5 2010 4:49PM

28

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Outdoor Booster Systems

OS-2133-E0-XXX

OS-3 3 Sector Outdoor System

ELECTRICAL SPECIFICATIONS Air Interface Frequency (MHz) Down Link Frequency (MHz) Up Link System Output Power IMD Specification Instantaneous Bandwidth Tx Gain Range (dB) Rx Path Insertion Loss Supply Voltage Noise Figure (dB) Rx Gain Range Input Intercept Point IIP3 (dBm) Tx Rejection In Rx Band (dB) VSWR Alarm Threshold (dB) Return Loss, All Ports (dB) Impedance All Ports (Ohms) GSM/EDGE/CDMA2000/WCDMA 2110-2170 (UMTS, -X1X series), 2110-2155 (AWS, -X4X series) 1920-1980 (UMTS, -X1X series), 1710-1755 (AWS, -X4X series) 105W** -65 dBc* 60 (UMTS, -X1X series) 45 (AWS, -X4X series) 0-17 Variable 0.5dB* (RF Bypass Mode) 180-264 VAC (-0XX series), -48VDC (-1XX series) 2.5 (Max @ 12dB Gain), 4.5 (Max @ 0 dB gain) 0-12 dB 0.0 100 adjustable 14 50

MECHANICAL SPECIFICATIONS Dimension HxWxD mm(ft) Weight(lbs) RF Connectors Number of MCPAs per Sector Number of Sectors 16 W x 40 H x 38 D 385 (175 kg) 7/16 DIN-F, N-F 1 3

ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range Ingress Protection Class Lightning Protection -20 C to +50 C IP55 20kA EIC 61000-4-5, 8/20

ORDERING INFORMATION Model Number OS-2133-E0-013 OS-2133-E0-043 OS-2133-E0-113 OS-2133-E0-143 Description Enclosure: 3I3O, UMTS (Band 1),220 VAC Enclosure: 3I3O, AWS (Band 4),220 VAC Enclosure: 3I3O, UMTS (Band ),-48 VDC Enclosure: 3I3O, AWS (Band 4),-48VDC Models above include: G3L-2129-140 amplifier modules Frequency-specific RF Conditioning Units 220 VAC Rectifiers (AC enclosures only) OS-2133-E0-041 Enclosure: 3I3O, AWS (Band 4), 220 VAC Incl: G3L-2129-140 amplifier module AWS RF Conditioning Unit 220VAC Rectifiers INST-2133-E0-041 AWS Upgrade Kit, includes: G3L-2129-140 amplifier module AWS RF Conditioning Unit 220 VAC Rectifier 3 3 4 1 1 1 2 1 1 1 Quantity 1 1 1 1

* Typical Performance** Typical, with G3L-2130-140 MCPA Module Inserted, 45 MHz IBW

Updated: May 18 2011 12:42PM

29

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

TMA Products

Power wave

Tower Mounted AmplifiersPowerwave offers one of the most extensive tower mounted amplifier (TMA) product portfolios, including single, twin and dual band TMAs. Our TMA design offers a low noise amplifier that provides superior receive system performance and reliability, and is fully compatible with 2G, 3G and 4G(LTE) systems. Powerwave TMAs are designed for the harshest environments to include desert and polar climates and extreme environments such as rain forests. Powerwave TMAs are also part of the Powerwave Clean Site Solutions which provides multiple benefits such as reduced installation cost, reuse of existing building permits and reduced visual impact to base stations.

Tower Mounted Amplifiers Power Distribution Unit Current Injectors

Base Station Products

POWERWAVE

Tower Mounted Amplifiers

TMA ProductsTower Mounted Amplifiers

TMA Type TMA-DD Micro Twin 2100TMA Twin 2600 TMA 800 Digital Dividend TMA Twin 800 AISG TMA-DD Twin 2100 15 MHz TMA-DD Twin 2100 15 MHz TMA-DD Twin 2100 15 MHz TMA-DD Twin 2100 15 MHz TMA Twin 900 AISG TMA Twin 900 AISG TMA Twin 900 AISG TMA Single 900 AISG TMA Single 900 AISG TMA Single 900 AISG TMA-DD EGSM TMA-DD 850 MHz SMR Rejection TMA-DD 1900

Up-Link (MHz) 1920-19802500-2700 832-862 824-849 1969.7-1984.7 1920.5-1935.5 1964.9-1979.9 1950-1965 890-915 880-908 890-915 890-915 890-915 890-915 880-915 824-849 1850-1910

Down-Link (MHz) 2110-21702620-2690 791-821 869-894 2110-2170 2110-2170 2110-2170 2110-2170 935-960 925-953 935-960 935-960 935-960 935-960 925-960 869-894 1930-1990 1805-1880 1805-1880 1805-1880

Part Number LGP215nnTT26-0000112-0n1 TT8D-0000112-0n1 24501, 24511 010-11177-0214 010-11182-02nn 010-11183-02nn 010-50025-0232 25001, 25011 25002, 25012 25014, 25016 25101, 25111 25102, 25112 25103, 25113 LGP192nn LGP174nn LGP175nn LGP18510, LGP18520 LGP18520, LGP18521 LGP185nn

Page33 35 37 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55

TMA-DD 1800 Twin AISG 2.0 1710-1785 TMA-DD 1800 Twin AISG 2.0 1710-1785 TMA-DD 1800 Twin AISG 2.0 1710-1785

31

Base Station Products

POWERWAVE

Tower Mounted Amplifiers

TMA ProductsTower Mounted Amplifiers

TMA TypeTMA-DD 1900 Twin TMA-DD 1900 Twin

Up-Link (MHz)1850-1910 1850-1910

Down-Link (MHz)1930-1990 1930-1990

Part NumberLGP186nn LGP18611

Page 56 57 58 59 60 61 62 63 6465 66 67

TMA Dual Band AWS with 700 Bypass

1710-1770 with 698-746 bypass

2110-2170 with 698746 bypass 2110-2170 with 698746 bypass 2110-2155 2110-2170 728-746 and 21102170 728-746 and 21102170 869-894 /1930-1990 1930-1990 with 824894 bypass 935-960 935-960

TSAW-07BP111-001 TTAW-07BP111-001 TTAW-0000112-001 TTAW-60BW111-001 TS07-AWDB111-001 TS07-AWDB112-001 TT08-19DB111-001 TT19-08BP111-001 TU09-000001n-001 TU9E-28BW01n-00n

TMA Twin Dual Band 1710-1770 with 698-746 AWS with 700 Bypass bypass TMA Micro Twin AWS TMA Micro Twin AWS TMA Dual Band 700/AWS TMA Dual Band 700/AWS TMA Twin 850/1900 Dual Band TMA Twin 1900 with 850 Bypass ACTIVE UGC 900 ACTIVE UGC 900 1710-1755 1710-1770 698-716 MHz and 17101770 MHz 698-716 MHz and 17101770 MHz 824-849 /1850-1910 1850-1910 with 824-894 bypass 890-915 890-915

32

LGP215nnMicro Twin Tower Mounted Amplifier Dual Duplex 2100 MHz Full Band

Tower Mounted Amplifiers

Introduction:Enables the LNA to be placed close to the Antenna. By improving the receive sensitivity the uplink coverage and capacity is increased and mobile talk time extended. Powerwave Twin 2100 TMA offers state of the art performance, size and weight enclosure in Twin configuration, two TMAs in one housing with market leading reliability.

Features:q

AISG 1.1 and 2.0 compatible Current Alarm Mode (When no AISG is connected) Twin configuration, 2 TMAs in one and same housing Market leading reliability Low Noise Figure Low TX insertion loss Easy to install wall mount bracket and hose clams for pole mount included No Maintenance

q

q

q

q

q

q

q

ELECTRICAL SPECIFICATIONSUplink Frequency Range (MHz) Rejection Gain (dB) Return Loss Noise Figure UL Output 3rd Order Intercept Point (dBm) Bypass Loss (dB) Max Input Power (dBm) Downlink Frequency Range (MHz) Return Loss Insertion Loss (dB) Intermodulation Power Handling, RMS Power Supply & Alarm Input Voltage (V) Alarm Functionality Power Consumption AISG Compatibility AISG Mode: 10-30; Current alarm mode: 9 -17 AISG Compatible. In case of no AISG command received current alarm mode. LGP21509, 19: 170-190 mA; LGP21508, 18: current alarm compatible with PDU LGP121nn @12 VDC, 1.5 W per LNA LGP21508, 09 AISG 1.1 (field upgradable to AISG 2.0); LGP21518, 19 AISG 2.0 2110-2170 >20 dB 0.3 dB, Typical @ 2 x 43 dBm Tx carriers, In receive band, 49 dBm (4x43 dBm) 1920-1980 >85 dB (2110-2170 MHz) 12 >18 dB 1.4 dB, Typical +25, Typical 1 million hours IP65 and IP68

MECHANICAL OUTLINE

APPROVALS AND TESTSSafety EMC EN 60 950 ETSI 125 113

INSTALLATION INSTRUCTIONSThe TMA brackets included as part of the TMA support wall mount or pole mount. Two hose clamps are included in the TMA package. The TMA can be installed in all directions except flat with backside up 30. Ground the TMA and torque the jumper cables with a torque wrench to 25 - 30 NM (18-22 ft lbs). For details see TMA Installation and Service Manual 044-05214. Seal the 7/16 connectors according to the in the package enclosed instruction 100-11279-001.

ACCESSORIESLGP21301, LGP21302 LGP23301, LGP23303 LGP12101, 02, 03, 04 D100301, LG705 D105104, D105103 D100315, D100313 Outdoor Current Injector (01 female , 02 male ANT conn.) Outdoor Current Injector (01 female , 02 male ANT conn.) Power Distribution Unit (01: 2 TMA module, 04: 6 TMAs 19) Indoor CIN cable (01: 7m, 05: 3m) Outdoor CIN Cable (04: 10.3m, 03: 3m) PDU Alarm Cable (15: 7m, 13: 3m) D100314, D100312 7060.00, 7060.05 7060.10, 7060.15 7070.10, 7070.30, 7070.50 PDU Power Cable (14: 7m, 12: 3m) CILOC (ANT) CILOC (BTS) MCU (10: AC, 30: 24V, 50: -48V)

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

Page 2 of 2 Updated: Nov 2 2011 1:31PM D031-08222 Rev D

Powerwave Technologies 1801 East St. Andrew Place, Santa Ana, CA 92705 USA Tel: 714-466-1000 Fax: 714-466-5800 www.powerwave.com [email protected]

34

TT26-0000112-0n1TMA Twin 2600 12 dB AISG 2.0

Tower Mounted Amplifiers

Introduction:Enables the LNA to be placed close to the Antenna. By improving the receive sensitivity the uplink coverage and capacity is increased and mobile talk time extended. Powerwave Twin 2600 TMA offers state of the art performance, size and weight enclosure in Twin configuration, two TMAs in one housing with market leading reliability.

Features:q

AISG compatible Current Alarm Mode (When no AISG is connected) Twin configuration, 2 TMAs in one and same housing Market leading reliability State of the art low Noise Figure Low TX insertion loss Easy to install, wall mount bracket and hose clams for pole mount included No Maintenance

q

q

q

q

q

q

q

ELECTRICAL SPECIFICATIONSUplink Frequency Range (MHz) Rejection Gain (dB) Return Loss Noise Figure UL Output 3rd Order Intercept Point (dBm) Bypass Loss (dB) Max Input Power (dBm) Downlink Frequency Range (MHz) Return Loss Insertion Loss (dB) Intermodulation Power Handling, RMS Power Supply & Alarm Input Voltage (V) Alarm Functionality Power Consumption AISG Compatibility AISG Mode: 10-30; Current alarm mode: 8 -30 AISG compatible or in case of no AISG command received current alarm mode 170-190 mA 18 0.4, Typical @ 2 x +43 dBm Tx carriers in receive band, < -117 dBm, reffered to antenna port >52 dBm (>160W) 2500-2570 >85 dB 12 >18 1.1 dB, Typical (TT26-0000112-011); 1.3 dB (TT26-0000112-001) >+24 80 dB 12 >18 dB +23 1 million hours per TMA IP68 228x169x120 (9x6.7x4.8) 82 dB 12 >18 dB 1.4 dB, Typical +25, Typical 2.0 dB, Typical +10 dBm 869-894 >18 dB 0.4, Typical 53.5 dBm 24501 AISG 1.1 (Field upgradable to AISG 2.0); 24511 AISG 2.0

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Rev A Updated: Feb 4 2010 11:29AM

39

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

010-11177-0214

Tower Mounted Amplifier

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN 60950 ETS 125 113 -40C to +65C (-40F to +149F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s; 20 kA (Shield) Aluminum >350.000 Hours IP 68 340x171x70 mm (13.4x6.7x2.8 inch) 18 dB Typical 1.2 dB, Max 1.7 dB > +23 18 dB Max 0.4 350.000 Hours IP68 340x171x70 mm (13.4x6.7x2.8 inch) 18 dB Typical 1.2 dB, Max 1.7 dB > +23 18 dB Max 0.4 350.000 Hours IP68 340x171x70 mm (13.4x6.7x2.8 inch) 18 dB Typical 1.2 dB, Max 1.7 dB > +23 18 dB Max 0.4 350.000 Hours IP 68 340x171x70 mm (13.4x6.7x2.8 inch) 18 dB Typical 1.2 dB, Max 1.7 dB > +23 18 dB Max 0.4 1 million hours per TMA IP68 228x169x120 (9x6.7x4.8) 82 dB 12 >18 dB 1.4 dB, Typical +25, Typical 2.0 dB, Typical +10 dBm 935-960 >18 dB 0.4, Typical 53.5 dBm 25001 AISG1.1 (Field upgradable to AISG 2.0); 25011 AISG 2.0

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Rev A Updated: Apr 18 2011 5:41PM

44

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

25002, 25012

TMA Twin 900 EGSM 28 MHz 12 dB SL AISG

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN60950, UL 1950, ETL ETS 300 342-3 -40C to +65C (-40F to +149F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s; 20 kA (Shield) Aluminum >1 million hours per TMA IP68 228x169x120 (9x6.7x4.8) 82 dB 12 >18 dB 1.4 dB, Typical +25, Typical 2.0, Typical +10 dBm 925-953 >18 dB 0.4, Typical 53.5 dBm 25002 AISG 1.1 (Field upgradable to AISG 2.0); 25012 AISG 2.0

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Rev A Updated: Dec 29 2009 12:47PM

45

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

25014, 25016

TMA Twin 900 16 dB AISG

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN60950, UL1950, ETL ETS 300 342-3 -40C to +65C (-40F to +149F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s, 8kA 8/20 s, 20 kA (Shield) Aluminum >1 million hours per TMA IP68 228x169x120 (9x6.7x4.8) 82 dB 16 >18 dB 1.4 dB, Typical +25, Typical 2.0 dB, Typical +10 dBm 935-960 >18 dB 0.4, Typical 53.5 dBm AISG 2.0

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Rev A Updated: Dec 9 2010 9:45AM

46

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

25101, 25111

TMA Single 900 12 dB SL AISG

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN60950, UL1950, ETL ETS 300 342-3 -40C to +65C (-40F to +149F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s, 8kA 8/20 s, 20 kA (Shield) Aluminum >1 million hours per TMA IP68 228x169x69 (9x6.7x2.7) 18 dB 1.4 dB, Typical +25, Typical 2.0 dB, Typical +10 dBm 935-960 >18 dB 0.4, Typical 53.5 dBm 25101 AISG1.1 (Field upgradable to AISG 2.0); 25111 AISG 2.0

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Rev A Updated: Apr 18 2011 5:43PM

47

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

25102, 25112

TMA Single 900 EGSM 28 MHz 12 dB SL AISG

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN60950, UL 1950, ETL ETS 300 342-3 -40C to +65C (-40F to +149F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s; 20 kA (Shield) Aluminum >1 million hours per TMA IP68 228x169x69 (9x6.7x2.7) 18 dB 1.4 dB, Typical +25, Typical 2.0, Typical +10 dBm 925-953 >18 dB 0.4, Typical 53.5 dBm 25102 AISG 1.1 (Field upgradable to AISG 2.0); 25112 AISG 2.0

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Rev A Updated: Feb 19 2010 6:10AM

48

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

25103, 25113

TMA Single 900 12 dB AISG

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN60950, UL1950, ETL ETS 300 342-3 -40C to +65C (-40F to +149F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s, 8kA 8/20 s, 20 kA (Shield) Aluminum >1 million hours per TMA IP68 228x169x69 (9x6.7x2.7) 18 dB 1.4 dB, Typical +25, Typical 2.0 dB, Typical +10 dBm 935-960 >18 dB 0.4, Typical 53.5 dBm 25103 AISG1.1 (Field upgradable to AISG 2.0); 25113 AISG 2.0

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Rev A Updated: Apr 18 2011 5:42PM

49

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

LGP192nn

Dual Duplex EGSM 900 MHz Full Band

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN 60 950 ETS 300 342-3 -40 C to +65 C (-40 F to +149 F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s; 20 kA (Shield) Aluminum >1 million hours IP65 169 x 272 x 89 (7x11x4) 83 dB 12 >20 dB, Typical < 1.7 dB, Typical > +23 2.0, Typical +10 925-960 > 20 dB, Typical 21 dB, Typical < 1.7 dB, Typical > +23, Typical 21 dB, Typical < 0.45 dB, Typical @ 2 x 43 dBm Tx carrier dBm (dBc), 1 million hours IP65 181 x 365 x 66 (7x12x4) 6.4 kg (14.1 lbs) Off white (NCS 1502-R) DIN 7/16 female Mounting kit for pole and wall is included 1850-1910 @1912 MHz, >10 dB 12 >20 dB < 1.6 dB > +23 20 dB < 0.5 dB 2 Tx@43 dBm (dBc), 54 dBm N/A

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

PNLGP175nn Updated: Apr 18 2011 5:38PM

52

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

LGP18510, LGP18520

Twin Dual Duplex 1800 MHz Full Band

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN 60 950 ETS 301 489 -40 C to +65 C (-40 F to +149 F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s; 20 kA (Shield) Aluminum >1 million hours IP 68 169 x 272.5 x 67.7 (7x11x3) 80 dB 12 >18 dB 1.5 dB, Typical +26 dBm, Typical < 3.0 dB, Typical +12 1805-1880 > 18 dB 0.4 dB, Typical @ 2 x 43 dBm Tx carriers, In receive band, 53 dBm LGP18510 AISG 1.1 (field upgrdable to AISG 2.0), LGP18520 AISG 2.0

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

D031-08228 Rev A Updated: May 30 2011 9:03AM

53

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

LGP18520, LGP18521

Twin Dual Duplex 1800 MHz Full Band

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN 60 950 ETS 301 489 -40 C to +65 C (-40 F to +149 F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s; 20 kA (Shield) Aluminum >1 million hours IP 68 169 x 272.5 x 67.7 (7x11x3) 80 dB 12 >18 dB 1.5 dB, Typical +26 dBm, Typical < 3.0 dB, Typical +12 1805-1880 > 18 dB 0.4 dB, Typical @ 2 x 43 dBm Tx carriers, In receive band, 53 dBm AISG 2.0

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Updated: Apr 18 2011 5:36PM

54

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

LGP185nn

Twin Dual Duplex 1800 MHz Full Band

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN 60 950 ETS 301 489 -40 C to +65 C (-40 F to +149 F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s; 20 kA (Shield) Aluminum >1 million hours IP 68 (LGP18501, 06 upgraded from IP65 to IP68 week 36 2011) 169 x 272.5 x 67.7 (7x11x3) 80 dB 12 >18 dB 1.5 dB, Typical +26 dBm, Typical < 3.0 dB, Typical +12 1805-1880 > 18 dB 0.4 dB, Typical @ 2 x 43 dBm Tx carriers, In receive band, 53 dBm LGP18501, 06 no AISG; LGP18507, 10 AISG 1.1 (field upgrdable to AISG 2.0), LGP18517, 20, 21 AISG 2.0

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

D031-08219 Rev D Updated: Sep 8 2011 10:32AM

55

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

LGP186nn

Twin Dual Duplex 1900 MHz Full Band

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC UL60 950, ETL FCC Part 15 -40 C to +65 C (-40 F to +149 F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s; 20 kA (Shield) Aluminum >1 million hours IP 68 (LGP18601, 06 upgraded from IP65 to IP68 week 36 2011) 169 x 272.5 x 67.7 (7x11x3) 80 dB 12 >18 dB 1.5 dB, Typical +26 dBm, Typical < 3.0 dB, Typical +12 1930-1990 > 18 dB 0.4 dB, Typical @ 2 x +43 dBm Tx carriers, In receive band, 1 million hours IP 68 169 x 272.5 x 67.7 (7x11x3) 80 dB 12 >18 dB 1.5 dB, Typical +26 dBm, Typical 3.0 dB, Typical +12 1930-1995 > 18 dB 0.5 dB, Typical @ 2 x +43 dBm Tx carriers, In receive band, 1 million hours IP67 minimum 250x169x82 (9.9x6.7x3.1) 25 dB rejection at 1700 and 1800 MHz 13 >18 dB +23 (Input IP3 >+11) 18 dB +11) 18 dB +10) AWS: 18 dB 55 dBm AISG 1.1 fully upgreadable to AISG 2.0 (AISG version only dependent on loaded SW version) TT08-19DB112001 has AISG 2.0 loaded from factory

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

Rev B Updated: Mar 28 2011 2:25PM

64

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Tower Mounted Amplifiers

TT19-08BP111-001

TMA Twin 1900 with 850 Bypass 12 dB AISG 1.1

ELECTRICAL SPECIFICATIONS* UL Frequency Range (MHz) UL Rejection UL Gain (dB) UL Return Loss UL Noise Figure UL Output 3rd Order Intercept Point (dBm) UL Bypass Loss (dB) UL Max Input Power (dBm) DL Frequency Range (MHz) DL Return Loss DL Insertion Loss (dB) Intermodulation Input Voltage (V) Alarm Functionality Power Consumption Power Handling, RMS AISG Compatibility MECHANICAL SPECIFICATIONS* Dimensions HxWxD mm(ft) Weight (lbs) Colors RF Connectors Mounting Kit ENVIRONMENTAL SPECIFICATIONS* Temperature Range Operational Transportation Storage Lightning Protection Housing MTBF Ingress Protection APPROVALS AND TESTS* Safety EMC EN60950 3GPP: TS 25.113 -40 C to +65 C (-40 F to +149 F) ETS 300 019-1-4 ETS 300 019-1-2 ETS 300 019-1-1 3 kA 10/350 s; 20 kA (Shield) Aluminum >1 million hours per TMA IP65 and IP68 250x169x137 mm (9.9x6.7x5.4) 77 dB 12 >18 +23 2.5, Typical +14 dBm 1930-1990 with 824-894 bypass >18 850 MHz, 82 dB Variable 0-12 in 1 dB steps >18 dB 1.5dB, typical at 12 dB gain +25, typical 1 million hours per TMA IP68 -40C to +65C (-40F to +149F) 230.5x171x160 (9.1x6.8x6.3) 18 dB 0.65 maximum 53.5 dBm TU9E-28BW011-001 AISG 1.1 (Field upgradable to AISG 2.0); TU9E-28BW012-001 AISG 2.0 880-908 >82 dB Variable 0-12 in 1 dB steps >18 dB 1.5dB, typical at 12 dB gain +25, typical 1 million hours

D031-08280 Rev A Updated: Apr 18 2011 5:37PM

69

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

TMA Products

LGP18104

PDU Lite Indoor (For Dual Band TMAs)

ELECTRICAL DATA Input Voltage Input Current (Max) Input Protection and Polarity Output Voltage Output Current (Max) Output Protection Sum Alarm Output Port MECHANICAL SPECIFICATIONS Dimensions, HxWxD, mm(ft) Weight (lbs) 19 1HU (19 x 1.75) 700 (1.55) 20-60 V DC, positive or negative 3x1 A Automatic Polarity Agile 12 V DC +/- 1 V 375 mA/port Automatic short-circuit protection, auto recovery Relay Normally Open and Normally Closed

ENVIRONMENTAL SPECIFICATIONS Temperature Range Humidity MTBF APPROVALS AND TESTS EMC Environmental ETS 300 342-3 ETS 300 019 -33 to +60 (-27 to +140) 5-95% RH non condensing >1 000 000 hours (over 100 years)

Updated: Sep 21 2009 8:25AM

70

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

TMA Products

LGP12101

PDU Lite Indoor

ELECTRICAL DATA Input Voltage Input Current (Max) Input Protection and Polarity Output Voltage Output Current (Max) Output Protection Sum Alarm Output Port MECHANICAL SPECIFICATIONS Dimensions, HxWxD, mm(ft) Weight (lbs) 3.9 x 0.8 x 2.4 in 120 g (0.3 lbs.) 20 to 60 V DC, positive or negative 1A Automatic Polarity Agile 12 V DC +/- 1 V 375 mA/port Automatic short-circuit protection, auto recovery Relay Normally Open and Normally Closed

ENVIRONMENTAL SPECIFICATIONS Temperature Range Humidity MTBF APPROVALS AND TESTS EMC Environmental ETS 300 342-3 ETS 300 019 -33 C to +60 C (-27 F to +140 F) 5-95% RH non condensing >1 million hours

D031-08280 Rev A Updated: Apr 18 2011 5:49PM

71

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

Base Station Products

POWERWAVE

Current Injectors

TMA ProductsCurrent Injectors

Frequency Range (MHz) 806-960 and 1710-2170

Return Loss (dB) >20

Insertion Loss (dB) 20

25

20

20 < 0.1 1.5 A 20 13

MECHANICAL SPECIFICATIONS* Connector Connector position Dimensions, HxWxD, mm(ft) Mounting Weight, with brackets, kg (lbs) Weight, without brackets, kg (lbs) Wind load, frontal/lateral/rear side 42 m/s Cd=1.6 (N) Maximum operational wind speed, m/s (mph) Survival wind speed, m/s (mph) Lightning protection Operating Temperature Radome Material Radome colour Packing size, HxWxD, mm (ft) Shipping weight, kg (lbs) Brackets 2 x 7/16 DIN female Bottom 710x280x125 (24x11x5) Pre-mounted standard bracket 7.7 (17) 4 (8.8) 189 42 55 DC grounded -40C to +60C GRP Light Gray 850x355x200 (29x12x10) 9.5 (20.9) 7456.00A, 7454.00, 7455.00, 7458.00

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

ANTENNA PATTERNS* For detailed patterns visit http://www.powerwave.com/rpa/.

D031-08018 Rev A Updated: Jul 15 2011 1:36AM

385

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

Single Band Antennas

POWERWAVE

X-Urban Cross Polarized Antennas, 824-896/870-960 MHz

Single Band AntennasCross Polarized X-Urban Cross Polarized Antennas, 824-896/870-960 MHz

Horizontal Beamwidth 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65

Gain dBi dBd 12.5/10.4 12.5/10.4 14.5/12.4 15.5/13.4 15/12.9 15/12.9 15/12.9 16.5/14.4 16.5/14.4 16.5/14.4 17.5/15.4 17.5/15.4 17.5/15.4 17.5/15.4 17/14.9 18/15.9 18/15.9 18/15.9 18/15.9

Tilt FET FET FET FET FET FET FET FET FET FET FET FET FET FET FET FET FET FET FET

Length 0.7m (2'3") 0.7m (2'3") 1.3m (4'3") 1.3m (4'3") 1.3m (4'3") 1.3m (4'3") 1.3m (4'3") 1.9m (6'2") 1.9m (6'2") 1.9m (6'2") 2.6m (8'6") 2.6m (8'6") 2.6m (8'6") 2.6m (8'6") 1.9m (6'2") 2.6m (8'6") 2.6m (8'6") 2.6m (8'6") 2.6m (8'6")

Part Number 7216.03 7282.03 7217.11 7217.04 7217.03 7263.01 7263.04 7255.03 7281.02 7281.04 7218.03 7218.04 7218.13 7218.14 7255.04 7218.05 7218.09 7218.15 7218.19

Page 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405

386

POWERWAVE

Single Band Antennas

7216.03

X-Urban Cross Polarized

POLARIZATION: X-Pol FREQUENCY (MHz): 880-960 HORIZONTAL BEAM WIDTH (): 65 GAIN (dBi dBd): 12.5/10.4 TILT: FET LENGTH: 0.7m (23)

ELECTRICAL SPECIFICATIONS* Frequency range (MHz) Frequency band (MHz) Gain (dBi/dBd) Polarization Nominal Impedance () VSWR Horizontal beam width, -3 dB () Vertical beam width, -3 dB () Electrical down tilt () Side lobe suppression, vertical 1st upper (dB) First null fill (dB) Vertical beam squint () Front to back ratio (dB) 180 30 coplanar Front to back ratio (dB) 180 30 total power Cross polar discrimination (XPD) 0 (dB) Cross polar discrimination (XPD)60 (dB) Far field coupling IM3, 2xTx&43dBm (dBc) Power handling, average per input (W) Power handling, average total (W) 20 >20

MECHANICAL SPECIFICATIONS* Connector Connector position Dimensions, HxWxD, mm(ft) Mounting Weight, with brackets, kg (lbs) Weight, without brackets, kg (lbs) Wind load, frontal/lateral/rear side 42 m/s Cd=1.6 (N) Maximum operational wind speed, m/s (mph) Survival wind speed, m/s (mph) Lightning protection Operating Temperature Radome Material Radome colour Packing size, HxWxD, mm (ft) Shipping weight, kg (lbs) Brackets 770x308x121 (26x1x5) 7.5 (16.5) 7456.00A, 7454.00, 7455.00, 7458.00 PVC 2 x 7/16 DIN female Bottom 660x256x50 (22x10x2) Pre-mounted standard bracket 7.3 (16) 3.6 (7.9) 222 42 55 (123) DC grounded

*All specifications subject to change without notice. Please contact your Powerwave representative for complete performance data.

ANTENNA PATTERNS* For detailed patterns visit http://www.powerwave.com/rpa/.

D031-08069 Rev A Updated: May 12 2011 3:27AM

387

Copyright 2011 Powerwave Technologies, Inc. All rights reserved. All specifications are subject to change without notice. Please contact your Powerwave representative for complete performance data.

POWERWAVE

Single Band Antennas

7282.03

X-Urban Cross Polarized

POLARIZATION: X-Pol FREQUENCY (MHz): 824-896 HORIZONTAL BEAM WIDTH (): 65 GAIN (dBi dBd): 12.5/10.4 TILT: FET LENGTH: 0.7m (23)

ELECTRICAL SPECIFICATIONS* Frequency range (MHz) Frequency band (MHz) Gain (dBi/dBd) Polarization Nominal Impedance () VSWR Horizontal beam width, -3 dB () Vertical beam width, -3 dB () Electrical down tilt () Side lobe suppression, vertical 1st upper (dB) First null fill (dB) Vertical beam squint () Front to back ratio (dB) 180 30 coplanar Front to back ratio (dB) 180 30 total power Cross polar discrimination (XPD) 0 (dB) Cross polar discrimination (XPD)60 (dB) Far field coupling IM3, 2xTx&43dBm (dBc) Power handling, average per input (W) Power handling, average total (W) 824-896 824-896 12.5/10.4 Linear slanted 45 50 9 22 >18 >20 >10 19 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10 20 >20 >10