588
3AL 91670 AAAA Ed.02 OPERATOR’S HANDBOOK Alcatel METRO OMSN Rel. 4.4B/5.2B 1640FOX Rel. 4.4B STM–1/4 Multiservice Node for Customer Premises 1650SMC Rel. 4.4B STM–1/4 Multiservice metro Node 1660SM Rel. 4.4B STM–16 Multiservice metro Node 1660SM Rel. 5.2B STM–64 Multiservice metro Node

1660 S M Oper R4

  • Upload
    fxx

  • View
    1.006

  • Download
    2

Embed Size (px)

Citation preview

Page 1: 1660 S M  Oper  R4

3AL 91670 AAAA Ed.02

OPERATOR’S HANDBOOK

AlcatelMETRO OMSN Rel. 4.4B/5.2B

1640FOX Rel. 4.4BSTM–1/4 Multiservice Node for Customer Premises

1650SMC Rel. 4.4BSTM–1/4 Multiservice metro Node

1660SM Rel. 4.4BSTM–16 Multiservice metro Node

1660SM Rel. 5.2BSTM–64 Multiservice metro Node

Page 2: 1660 S M  Oper  R4

3AL 91670 AAAA Ed.02

Page 3: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

1

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

METRO OMSN REL. 4.4/5.2A OPERATOR’S HDBK

TABLE OF CONTENTS

LIST OF FIGURES AND TABLES 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 HANDBOOK STRUCTURE AND CONFIGURATION CHECK 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 General information 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Handbook applicability 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 Purpose of the handbook 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 Handbook configuration check 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.4.1 Notes on Ed. 01 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4.2 Notes on Ed. 02 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 PRODUCT-RELEASE HANDBOOKS 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 SAFETY NORMS AND LABELS 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 First aid for electric shock 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Norms and labels 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 HANDBOOK DESCRIPTION 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5 GENERAL ON ALCATEL CUSTOMER DOCUMENTATION 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 Products, product-releases, versions and Customer Documentation 21. . . . . . . . . . . . . . 5.2 Handbook supply to Customers 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 Aims of standard Customer Documentation 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4 Handbook Updating 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.4.1 Changes introduced in the same product-release (same handbook P/N) 22. . . . . . . . . . . . 5.4.2 Supplying updated handbooks to Customers 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.3 Changes due to a new product-release 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.5 Customer documentation supply on CD–ROM 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5.1 Contents, creation and production of a CD–ROM 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5.2 Use of the CD–ROM 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5.3 CD–ROM identification 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5.4 CD–ROM updating 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ED DATE CHANGE NOTE APPRAISAL AUTHORITY ORIGINATOR

01 041119 C.FAVERO ITAVE P.GHELFI ITAVE

02 050414 ECR 23082 C.FAVERO ITAVE P.GHELFI ITAVE

METRO OMSNRel. 4.4/5.2AOPERATOR’S HANDBOOK

J. MIR – S. MAGGIO

J. MIR – S. MAGGIO

Page 4: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

2

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

LIST OF FIGURES AND TABLES

TABLESTable 1. Handbooks related to the specific product hardware 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 2. Handbooks related to the specific product SW management and local product control 8. . Table 3. Handbooks related to ATM specific product SW 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4. Handbooks related to PR_EA specific product SW 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5. Handbook related to ISA–PR specific product SW 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6. Handbook related to ISA–ES specific product SW 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7. Handbooks common to Alcatel Network Elements using 1320CT platform 10. . . . . . . . . . . . . Table 8. Optional handbooks common to 16xxSM 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 9. Documentation on CD–ROM 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

3

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

1 HANDBOOK STRUCTURE AND CONFIGURATION CHECK

1.1 General information

WARNING

ALCATEL makes no warranty of any kind with regards to this manual, and specifically disclaims theimplied warranties of merchantability and fitness for a particular purpose. ALCATEL will not be liablefor errors contained herein or for damages, whether direct, indirect, consequential, incidental, orspecial, in connection with the furnishing, performance, or use of this material.

NOTICE

The product specification and/or performance levels contained in this document are for informationpurposes only and are subject to change without notice. They do not represent any obligation on thepart of ALCATEL.

COPYRIGHT NOTIFICATION

The technical information of this manual is the property of ALCATEL and must not be copied,reproduced or disclosed to a third party without written consent.

1.2 Handbook applicability

This handbook applies to the following product-releases:

PRODUCT ANV P/N

1640FOX (Rel. 4.4) 3AL 37491 AAAA

1650SMC (Rel. 4.4) 3AL 36641 AAAA

1660SM (Rel. 4.4) 3AL 36301 AAAA

1660SM (Rel. 5.2) 3AL 36301 AAAA

PRODUCT RELEASEVERSION

(N.B.)ANV P/N

1640FOX Rel.4.4 B 3AL 80997 AEAA

1650SMC Rel.4.4 B 3AL 81018 AEAA

1660SM Rel.4.4 B 3AL 81025 AEAA

1660SM Rel.5.2 B 3AL 81407ACAA

For further information on the Alcatel software product and its physical distribution support refer to the“Introduction” section.

Page 6: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

4

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

N.B. NOTES FOR HANDBOOKS RELEVANT TO SOFTWARE APPLICATIONS

Handbooks relevant to software applications (typically the Operator’s Handbooks) are notmodified unless the new software ”version” distributed to Customers implies man–machineinterface changes or in case of slight modifications not affecting the understanding of theexplained procedures.Moreover, should the screen prints included in the handbook contain the product-release’s”version” marking, they are not replaced in the handbooks related to a subsequent version, ifthe screen contents are unchanged.

1.3 Purpose of the handbook

This Handbook contains detailed information for the METRO OMSN 1640FOX, 1650SMC, 1660SMequipment management. Unless otherwise specified, the menus have to be used for all the equipments.

This handbook describes the operations concerning commissioning, operation and maintenance that theoperators must carry out as indicated by the specific software application(s) referred to in this handbook(see para. 1.2 on page 3).

This handbook must be used together with the associated Technical Handbook ( see Table 1. on page7) and the 1320CT associated documentation ( see Table 7. on page 10) does not replicate informationcontained into it.In particular, all cautions relevant to safety, rules for EMC and ESD, as well as warnings regardingoperations that may cause damages to the equipment, are not duplicated here, but must be retrieved fromthe Technical Handbook.

When using this handbook it is assumed that the Operators know:

• the structure (hardware composition) and all the possible operating modes of the equipment(product-release) this handbook refers to.

• how to use a PC and the Windows ambient applications

Page 7: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

5

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

1.4 Handbook configuration check

This handbook is a collection of documents (each contained in a specific section) that can haveeditions different from one another.The Edition of the whole handbook is that of Section 1 (HANDBOOK GUIDE).The edition of the enclosed documents indicated in the following table is that of thecorresponding original internal document.

HANDBOOK EDITION 01 02 03 04 05

REGISTER AND SECTION TITLE SECTION EDITION

1 HANDBOOK GUIDE 01 02

2 INTRODUCTION MANUAL 01 02

3 NE MANAGEMENT MANUAL 01 02

4 MAINTENANCE MANUAL 01 02

5 SIBDL MANUAL 01 02

1.4.1 Notes on Ed. 01

Ed.01 issued on NOVEMBER 2004, is the first released and validated version of the handbook.

1.4.2 Notes on Ed. 02

Ed.02 issued on APRIL 2005, is the second released and validated version of the handbook.

New description added:

– ISA ES4–8FE SMII mode and GMII mode

Page 8: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

6

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

Page 9: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

7

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

2 PRODUCT-RELEASE HANDBOOKS

The list of handbooks given here below is valid on the issue date of this Handbook andcan be changed without any obligation for ALCATEL to update it in this Handbook.

Some of the handbooks listed here below may not be available on the issue date of thisHandbook.

The standard Customer Documentation in the English language for the equipment whoseproduct-release-version is stated in para.1.2 on page 3 consists of the following handbooks:

Table 1. Handbooks related to the specific product hardware

REF HANDBOOK Part NumberTHIS

HDBK

1

1640FOX Rel.4.4Technical Handbook

3AL 91666 AAAA

1Provide information regarding Equipment description, Maintenance,Hardware setting documentation.

2

1640FOX Rel.4.4Installation Handbook

3AL 91666 BAAA

2Provide information regarding Equipment Installation, according toA–Installation Engineering Dept. rules.

3

1640FOX Rel.4.4Turnup & Commissionig Handbook

3AL 91666CAAA

3Provide information regarding Equipment Turn–On, Test and Operation,according to A–Installation Engineering Dept. rules.

4

1650SMC Rel.4.4Technical Handbook

3AL 91667 AAAA

4Provide information regarding Equipment description, Maintenance,Hardware setting documentation.

5

1650SMC Rel.4.4Installation Handbook

3AL 91667 BAAA

5Provide information regarding Equipment Installation, according toA–Installation Engineering Dept. rules.

6

1650SMC Rel.4.4Turnup & Commissionig Handbook

3AL 91667 CAAA

6Provide information regarding Equipment Turn–On, Test and Operation,according to A–Installation Engineering Dept. rules.

Page 10: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

8

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

REFTHIS

HDBKPart NumberHANDBOOK

7

1660SM Rel.4.4Technical Handbook

3AL91668 AAAA

7Provide information regarding Equipment description, Maintenance,Hardware setting documentation.

8

1660SM Rel.4.4Installation Handbook

3AL 91668 BAAA

8Provide information regarding Equipment Installation, according toA–Installation Engineering Dept. rules.

9

1660SM Rel.4.4Turnup & Commissionig Handbook

3AL 91668CAAA

9Provide information regarding Equipment Turn–On, Test and Operation,according to A–Installation Engineering Dept. rules.

10

1660SM Rel.5.2 “Version B”Technical Handbook

3AL91669 AAAA

10Provide information regarding Equipment description, Maintenance,Hardware setting documentation.

11

1660SM Rel.5.2Installation Handbook

3AL 91669 BAAA

11Provide information regarding Equipment Installation, according toA–Installation Engineering Dept. rules.

12

1660SM Rel.5.2Turnup & Commissionig Handbook

3AL 91669 CAAA

12Provide information regarding Equipment Turn–On, Test and Operation,according to A–Installation Engineering Dept. rules.

Table 2. Handbooks related to the specific product SW management and local product control

REF HANDBOOK Part NumberTHIS

HDBK

13

METRO OMSN REL. 4.4 & 5.2 “Version B”CT Operator’s Handbook

3AL 91670 AAAA

13Provides METRO OMSN “SDH” Craft Terminal screens and operationalprocedures

Page 11: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

9

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

Table 3. Handbooks related to ATM specific product SW

REF HANDBOOK Part NumberTHIS

HDBKor note

14ATM Rel.1.2Operator’s Handbook

3AL 80814 AAAA

15ATM Rel.2.0Operator’s Handbook

3AL 81826 AAAA

16ATM Rel.2.1Operator’s Handbook

3AL 89777 AAAA

17ATM Rel.2.2Operator’s Handbook

3AL 91714 AAAA

Provide ATM Terminal screens and operational procedures

Table 4. Handbooks related to PR_EA specific product SW

REF HANDBOOK Part NumberTHIS

HDBKor note

18PR_EA Rel. 1.1Operator’s Handbook

3AL 81062 BAAA

Provides “Packet Ring Edge Aggregator” Terminal screens and operationalprocedures

Table 5. Handbook related to ISA–PR specific product SW

REF HANDBOOK ANV Part No.FACTORY

Part No.

THIS

HDBK

19ISA–PR Rel. 1.0Operator’s Handbook

3AL 81771 AAAA ––

20ISA–PR Rel. 1.1Operator’s Handbook

3AL 91658 AAAA ––

21ISA–PR Rel. 1.2Operator’s Handbook

3AL 91715 AAAA ––

Provides ISA_PR board Craft Terminal screens and operational procedures

Page 12: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

10

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

Table 6. Handbook related to ISA–ES specific product SW

REF HANDBOOK ANV Part No.THIS

HDBK

22ISA–ES1 Rel. 1.0Operator’s Handbook

3AL 89872 AAAA

23ISA–ES1/ES4 Rel. 1.1Operator’s Handbook

3AL 89871 AAAA

24ISA–ES1/ES4 Rel. 1.2Operator’s Handbook

3AL 91804 AAAA

25ISA–ES16 Rel. 2.0Operator’s Handbook

3AL 89870 AAAA

26ISA–ES16 Rel. 2.1Operator’s Handbook

3AL 91716 AAAA

Provides ISA_ES board Craft Terminal screens and operational procedures

Table 7. Handbooks common to Alcatel Network Elements using 1320CT platform

REF HANDBOOK Part Number

THIS

HDBK

OR

NOTE

27

1320CT 3.xBasic Operator’s Handbook

3AL 79551 AAAA

27Provides general information and operational procedures common to all 1320CT(Craft terminal) of Alcatel InfoModel Network Elements.

28

1330AS Rel. 6.5Operator’s Handbook

3AL 88876 AAAA

28Provides detailed information and operational procedures regarding the alarmSurveillance software embedded in the 1320CT software package.

29

ELB 2.XOperator’s Handbook

3AL 88877 AAAA

29Provide detailed information and operational procedures regarding the EventLog Browsing software embedded in the 1320CT software package.

Page 13: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

11

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

Table 8. Optional handbooks common to 16xxSM

REF HANDBOOK ANV Part No.FACTORYPart No.

THISHDBK

30

S9–16xxSMSystem Installation Handbook

3AL 78901 AAAA 955.100.692 N

30Provides general installation rules necessary to install the Optinex familyequipment in the S9 Rack .

31

Optinex RACK–16xxSMSystem Installation Handbook

3AL 38207 AAAA 955.110.202 L

31Provides general installation rules necessary to install the Optinex familyequipment in the Optinex Rack .

N.B. Handbooks REF. 30 and 31 are available only on paper support.

Table 9. Documentation on CD–ROM

See para. 5.5 on page 23

REF CD–ROM TITLE Part Number

32METRO OMSN 4.4 & 5.2 CD–ROM EN 3AL 91671 AAAA

32Contains, in electronic format, the following handbooks: REF. 1 to 13

331320CT 3.x BASIC CD–ROM–DOC EN 3AL79552 AAAA

33Contains, in electronic format, the following handbooks: REF. 27 to 29

34ATM 1.2 CD–ROM–DOC EN 3AL 80815 AAAA

34Contains, in electronic format, the following handbook: REF. 14 on page 9

35ATM 2.0 CD–ROM–DOC EN 3AL 81829 AAAA

35Contains, in electronic format, the following handbook: REF. 15 on page 9

36ATM 2.1 CD–ROM–DOC EN 3AL 89778 AAAA

36Contains, in electronic format, the following handbook: REF. 16 on page 9

37ATM 2.2 CD–ROM–DOC EN 3AL 91714 AAAA

37Contains, in electronic format, the following handbook: REF. 17 on page 9

38PR_EA 1.1 CD–ROM EN 3AL 81063 BAAA

38Contains, in electronic format, the following handbook: REF. 18 on page 9

Page 14: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

12

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

REF Part NumberCD–ROM TITLE

39PR 1.0 CD–ROM EN 3AL 81769 AAAA

39Contains, in electronic format, the following handbook: REF. 19 on page 9

40PR 1.1 CD–ROM EN 3AL 91659 AAAA

40Contains, in electronic format, the following handbook: REF. 20 on page 9

41PR 1.2 CD–ROM EN 3AL 91718 AAAA

41Contains, in electronic format, the following handbook: REF. 21 on page 9

42ES1 1.0 CD–ROM EN 3AL89875 AAAA

42Contains, in electronic format, the following handbook: REF. 22 on page 10

43ES1/ES4 1.1 CD–ROM EN 3AL89871 AAAA

43Contains, in electronic format, the following handbook: REF. 23 on page 10

44ES1/ES4 1.2 CD–ROM EN 3AL91805 AAAA

44Contains, in electronic format, the following handbook: REF. 24 on page 10

45ES16 2.0 CD–ROM–DOC EN 3AL 89873 AAAA

45Contains, in electronic format, the following handbooks: REF. 25 on page 10

46ES16 2.1 CD–ROM–DOC EN 3AL 91719 AAAA

46Contains, in electronic format, the following handbooks: REF. 26 on page 10

Page 15: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

13

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

3 SAFETY NORMS AND LABELS

3.1 First aid for electric shock

Do not touch the patient with bare hands until the circuit has been opened.

Open the circuit by switching off the line switches. If that is not possible, protect yourself with drymaterial and free the patient from the conductor.

ARTIFICIAL RESPIRATION

It is important to start mouth to mouth resuscitation at once and seek doctor help immediately.

TREATMENT OF BURNS

This treatment should be used after the patient has regained consciousness. It can also be employed whilethe artificial respiration is being applied (in this case there should be at least two persons present).

WARNING:

• Do not attempt to remove his clothing from the burnt parts;

• Apply dry gauze on the burns;

• Do not apply ointments or other oily substances.

Page 16: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

14

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

Mouth to mouth resuscitation method

1

2

3

4

5

6

Lay the patient supine with his arms parallel with the body, if the patient is layingon an inclined plane, make sure that his stomach is slightly lower than his chest.Open the patient’s mouth and check that there are no extraneous bodies in hismouth (dentures, chewing–gum etc.),

Kneel beside the patient level with his head. Puta hand under the patient’s head and one underhis neck (see fig.) Lift the patient’s head and letit recline backwards as far as possible

Shift the hand from the patient’s neck to is chin:place your thumb between his chin and hismouth, the index along his jawbone, and keep theother fingers closed together (see fig.). Whileperforming these operations take a good supplyof oxygen by taking deep breaths with yourmouth open.

With your thumb between the patient’s chin andmouth keep his lips together and blow into hisnasal cavities (see fig.)

While performing these operations observe if thepatient’s chest rises (see fig.) If not it is possiblethat his nose is blocked: in that case open thepatient’s mouth as much as possible by pressingon his chin with your hand, place your lips aroundhis mouth and blow into his oral cavity. Observeif the patient’s chest heaves. This secondmethod can be used instead of the first evenwhen the patient’s nose is kept closed bypressing the nostrils together using the hand youwere holding his head with. The patient’s headmust be kept sloping backwards as much aspossible.

Start with ten rapid expirations, hence continue at a rate of twelve/fifteenexpirations per minute. Go on like this until the patient has regainedconsciousness, or until a doctor has ascertained his death.

Page 17: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

15

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

3.2 Norms and labels

Refer to the Technical Handbook associated to ALCATEL’s designed and manufactured equipmentto obtain the following information:

– COMPLIANCE WITH EUROPEAN NORMS.

– SAFETY RULES

• General rules

• Harmful optical signals

• Risk of explosion

• Moving mechanical parts

• Heat–radiating Mechanical Parts

– ELECTROMAGNETIC COMPATIBILITY

– ELECTROSTATIC DISCHARGERS (ESD)

– EQUIPMENT LABELS

Identical or similar information on Personal Computer, Work–Station etc., other than ALCATEL’s, loadedwith software applicative described in this Handbook, is supplied in the Constructor’s technicaldocumentation.

Page 18: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

16

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

Page 19: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

17

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

4 HANDBOOK DESCRIPTION

This handbook is composed of the following Manuals:

SECTION 1: HANDBOOK GUIDE (This document)

The Handbook Guide gives general information on the application and use of the Handbook. TheHandbook Guide includes the following chapters:

– Chapter 1: Handbook structure and configuration check. This chapter gives information on the wholehandbook application, composition and evolution.

– Chapter 2: Product-release handbooks. This chapter lists the handbooks the Operator should havein order to carry out the tasks allowed by the specific product–release this handbook refers to.

– Chapter 3: Safety norms and labels

– Chapter 4: Handbook description

– Chapter 5: General on Alcatel Customer Documentation

SECTION 2: INTRODUCTION Manual

The Introduction Manual describes the main features of the graphical interface and provides a generaloverview of the system architecture and the different functionalities provided by the Craft Terminal. TheIntroduction Manual includes the following chapters:

– Chapter 1: Introduction. This chapter gives the structure of this manual.

– Chapter 2: General description of the Craft Terminal. The Craft Terminal is introduced and thesoftware product listed. The Craft Terminal main functionality in the NE management (EML–USM)are listed and briefly described.

– Chapter 3: Acronyms and abbreviations. The acronyms used in all the operator manuals are listed.

– Chapter 4: Glossary of terms. Definitions concerning the acronyms.

SECTION 3: NETWORK ELEMENT MANAGEMENT Manual

The aim of this document is to describe the Craft Terminal view, inserting operative information.The Network Element Manual includes the following chapters:

– Chapter 1: Introduction. This chapter gives the structure of this manual.

– Chapter 2: General introduction on views and menus. The view organization is presented and themenus available listed and briefly described.

– Chapter 3: NE management supervision. This chapter is dedicated to the NE states and NE access.

– Chapter 4: NE management general configuration. In this chapter general configuration referred tothe equipment management are described (CT access, NE Time, Alarm Configuration etc).

– Chapter 5: Security Management. In this chapter configuration referred to the Security managementare described (ACD level and Manager list).

– Chapter 6: External input and output points management. This chapter describes how to display andset the input/output environmental alarm (housekeeping alarm).

Page 20: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

18

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

– Chapter 7: Diagnosis management. In this chapter are specified: access to the Alarm Surveillanceto show the alarm condition, abnormal condition list (as result of operator’s command), access to theEvent and Alarm Log file and Internal Link Monitor.

– Chapter 8: Communication and Routing management. In this chapter are presented thecommunication and routing parameters, concerning the OSI and IP communication protocols forthe local NE, the OS and each other related NE in order to provide a global communicationcapabilities inside the network

– Chapter 9: Equipment management. This chapter deals mainly with the setting and changing of theboards present on the Equipment and undertaking board protection operations.

– Chapter 10: Board view. This chapter permits to show the physical port available in a specific board(alarm synthesis and port symbol), to access the port view and to change the physical interface.

– Chapter 11: Port view. This chapter permits to set and show the transmission resources referred tothe Port.

– Chapter 12: Equipment Protection management (EPS). This chapter permits to manage the EPSprotection, setting the relevant configuration.N.B. EPS is not applicable in 1640FOX

– Chapter 13: Multiplex Section protection management. This chapter permits to manage the MSPprotection.

– Chapter 14: Transmission view. This chapter permits to show and set the Termination Point of theequipment, thus having an overview of the complete signal flow of the various port.

– Chapter 15: Cross connection management. This chapter permits to manage the connection of thepaths.

– Chapter 16: Overhead management. This chapter permits to manage the Overhead, setting therelevant configuration.

– Chapter 17: Performance Monitoring management. This chapter permits to set and showPerformance Monitoring parameters and data.

– Chapter 18: Synchronization management. This chapter permits to set and show Synchronizationparameters and status.

– Chapter 19: MS–SPRing Management. This chapter permits to set the MS–SPRing protection of theNEN.B. MS–SPRing Management menu is available only for 1660SM

– Chapter 20: ISA port Configuration. This chapter describes the operations necessary for theATM/PR_EA/Ethernet boards creation and the ATM/PR_EA/Ethernet TTPs creation.

– Chapter 21: Software management. This chapter permits to update the NE by means downloadprocedure and to manage NE software.

Page 21: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

19

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

SECTION 4: NETWORK ELEMENT MAINTENANCE Manual

This document aims at introducing the Maintenance procedure, inserting information useful to identifyalarms and troubleshoot the NE.The Maintenance Manual includes the following chapters:

– Chapter 1: Introduction. This chapter gives the structure of this manual.

– Chapter 2: Craft Terminal Maintenance Introduction.This chapter:

• list the maintenance steps;• for the “Maintenance of the Personal Computer”, refers to the personal Computer

manual;• describes the problem with Craft terminal (shut–down and restart of the PCis

indicated).

– Chapter 5: Troubleshooting (Corrective Maintenance). Detection location and correction of failureare presented.

– Chapter 6: Unit replacement with spare. The replacement procedure is detailed.

– Chapter 7: Upgrading with New Hardware. The Hardware upgrading procedure is detailed.

– Chapter 8: FLASH card substitution. The FLASH card substitution procedure is detailed.

SECTION 5: SIBDL Manual

This document describes the download procedure with SIBDL.The SIBDL Manual includes the following chapters:

– Chapter 1: Introduction

– Chapter 2: Download with SIBDL configuration

– Chapter 3: Configuration for SIBDL

Page 22: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

20

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

Page 23: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

21

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

5 GENERAL ON ALCATEL CUSTOMER DOCUMENTATION

5.1 Products, product-releases, versions and Customer Documentation

A ”product” is defined by the network hierarchical level where it can be inserted and by the whole ofperformance and services for which it is meant.A ”product” evolves through successive ”product-releases” which are the real products marketed fortheir delivery at a certain ”product-release” availability date.

So, a ”product–release” defines a set of hardware components and a software package which, as a whole,identify the possible network applications and the equipment performance which the specific”product-release” has been designed, engineered and marketed for.

In some cases a ”product-release” has further development steps, named ”versions”, that are born toimprove or add some performance (mainly software) with respect to the previous version, or for bug fixingpurposes.

A ”product-release” has its own standard Customer Documentation, composed by one or morehandbooks.

A new ”version” of a ”product-release” may or may not produce a change in the status of the CustomerDocumentation set, as described in para.5.4 on page 22.

5.2 Handbook supply to Customers

Handbooks are not automatically delivered together with the equipment they refer to.The number of handbooks per type to be supplied must be decided at contract level.

5.3 Aims of standard Customer Documentation

Standard Customer Documentation, referred to hereafter, must be always meant as plant-independent.Plant-dependent documentation, if envisaged by the contract, is subjected to commercial criteria as faras contents, formats and supply conditions are concerned (plant-dependent documentation is notdescribed here).

Standard hardware and software documentation is meant to give the Customer personnel the possibilityand the information necessary for installing, commissioning, operating and maintaining the equipmentaccording to Alcatel–Telecom Laboratory design choices.In particular the contents of the handbooks associated to the software applications focus on theexplanation of the man-machine interface and of the operating procedures allowed by it.

Consequently, no supply to the Customers of design documentation (like software source programs,programming tools, etc.) is envisaged.

Page 24: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

22

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

5.4 Handbook Updating

The handbooks associated to the ”product–release” are listed in para.2 on page 7.Each handbook is identified by:– the name of the ”product-release” (and ”version” when the handbook is applicable to the versions

starting from it, but not to the previous ones),– the handbook name,– the handbook P/N,– the handbook edition (usually first edition=01),– the handbook issue date. The date on the handbook does not refer to the date of print but to the date

on which the handbook source file has been completed and released for the production.

5.4.1 Changes introduced in the same product-release (same handbook P/N)

The edition and date of issue might change on future handbook versions for the following reasons:

– only the date changes (pointed out in the Table of Contents) when modifications are made to theeditorial system not changing the technical contents of the handbook.

– the edition, hence the date, is changed because modifications made concern technical contents. Inthis case:• the table in para.1.4 on page 5 indicates the section(s) edition change;• in each section, the main changes with respect to the previous edition are listed;• in affected chapters of each section, revision bars on the left of the page indicate modifications

in text and drawings (this is done after the first officially released and validated version).

Changes concerning the technical contents of the handbook cause the edition number increase (e.g. fromEd.01 to Ed.02). Slight changes (e.g. for corrections) maintain the same edition but with the addition ofa version character (e.g. from Ed.02 to Ed.02A).

NOTES FOR HANDBOOKS RELEVANT TO SOFTWARE APPLICATIONS

Handbooks relevant to software applications (typically the Operator’s Handbooks) are notmodified unless the new software ”version” distributed to Customers implies man–machineinterface changes or in case of slight modifications not affecting the understanding of theexplained procedures.Moreover, should the screen prints included in the handbook contain the product-release’s”version” marking, they are not replaced in the handbooks related to a subsequent version, ifthe screen contents are unchanged.

5.4.2 Supplying updated handbooks to Customers

Supplying updated handbooks to Customers who have already received previous issues is submitted tocommercial criteria.By updated handbook delivery it is meant the supply of a complete copy of the handbook new issue(supplying errata–corrige sheets is not envisaged).

5.4.3 Changes due to a new product-releaseA new product-release changes the handbook P/N and the edition starts from 01. In this case the modifiedparts of the handbook are not listed.

Page 25: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

23

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

5.5 Customer documentation supply on CD–ROM

In the following by ’CD–ROM’ it is meant ’Customer Documentation on CD–ROM’

5.5.1 Contents, creation and production of a CD–ROM

In most cases, a CD–ROM contains in read–only eletronic format the documentation of oneproduct–release(–version) and for a certain language.In some other cases, the same CD–ROM can contain the documentation of differentproduct–release(–version)s for a certain language.

As a general rule:

– CD–ROMs for Network Management products do not contain:

• the Installation Guides

• the documentation of system optional features that Customers could not buy from Alcateltogether with the main applicative SW.

– CD–ROMs for Network Elements products do not contain:

• the documentation of system optional features (e.g. System Installation Handbooks related toracks that Customers could not buy from Alcatel together with the main equipment).

A CD–ROM is obtained collecting various handbooks and documents in .pdf format. Bookmarks andhyperlinks make the navigation easier. No additional information is added to each handbook, so that thedocumentation present in the CD–ROMs is exactly the same the Customer would receive on paper.

The files processed in this way are added to files/images for managing purpose and a master CD–ROMis recorded.

Suitable checks are made in order to have a virus–free product.

After a complete functional check, the CD–ROM image is electronically transferred to the archive of theProduction Department, so that the CD–ROM can be produced and delivered to Customers.

Page 26: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

24

02

SC.1:HANDBOOK GUIDE

/3AL 91670 AA AA

24

24

5.5.2 Use of the CD–ROM

The CD–ROM can be used both in PC and Unix WS environments.

The CD–ROM starts automatically with autorun and hyperlinks from the opened “Index” document permitto visualize the .pdf handbooksOther hyperlinks permit to get, from the Technical handbooks, the specific .pdf setting documents.

In order to open the .pdf documents Adobe Acrobat Reader Version 4.0 (minimum) must have beeninstalled on the platform.The CD–ROM doesn’t contain the Adobe Acrobat Reader program. The Customer is in charge of gettingand installing it.ReadMe info is present on the CD–ROM to this purpose.

Then the Customer is allowed to read the handbooks on the PC/WS screen, using the navigation andzooming tools included in the tool, and to print selected parts of the documentation through a local printer.

5.5.3 CD–ROM identification

Each CD–ROM is identified:

Each CD–ROM is identified:

1 ) by the following external identifiers, that are printed on the CD–ROM upper surface:– the name of the ”product–release(s)” (and ”version” if applicable)– a writing indicating the language(s),– the CD–ROM P/N (Factory P/N and ANV P/N),– the CD–ROM edition (usually first edition=01)

2 ) and, internally, by the list of the source handbooks and documents (P/Ns and editions) by whosecollection and processing the CD–ROM itself has been created.

5.5.4 CD–ROM updating

The list of source handbook/document P/Ns–editions indicated in previous para. 5.5.3 point 2 ) , inassociation with the CD–ROM’s own P/N–edition, is also loaded in the Alcatel–Information–System as astructured list.Whenever a new edition of any of such handbooks/documents is released in the Alcatel archive system,a check in the Alcatel–Information–System is made to identify the list of CD–ROMs that must be updatedto include the new editions of these handbooks/documents.This causes the planning and creation of a new edition of the CD–ROM.Updating of CD–ROMs always follows, with a certain delay, the updating of the single handbookscomposing the collection.

END OF DOCUMENT

Page 27: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

1

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

METRO OMSN REL. 4.4/5.2A OPERATOR’S HDBK

TABLE OF CONTENTS

LIST OF FIGURES AND TABLES 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 INTRODUCTION 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Scope 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.1 Document scope 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.2 Target audience 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2 Reading rules 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.1 Menu options 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 GENERAL DESCRIPTION OF THE CRAFT TERMINAL 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Introduction 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Alcatel software product and licence delivered to the customer 6. . . . . . . . . . . . . . . . . . .

2.2.1 Software product and licences description 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.2 1640FOX Software products and licences list and part numbers 7. . . . . . . . . . . . . . . . . . . 2.2.3 1650SMC Software products and licences list and part numbers 8. . . . . . . . . . . . . . . . . . 2.2.4 1660SM Software products and licences list and part numbers 9. . . . . . . . . . . . . . . . . . . .

2.3 Craft Terminal main functionalities in the NE management 10. . . . . . . . . . . . . . . . . . . . . . . . 2.3.1 Network Element management supervision 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.2 Network Element general configuration 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.3 Security Management 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.4 External input and output point management 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.5 Diagnosis management 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.6 Communication and routing management 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.7 Equipment and board management 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.8 Port management 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.9 Protection management 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.10 Transmission management 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.11 Cross Connection management 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.12 Performance monitoring management 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.13 Synchronization management 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.14 ISA port Configuration 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.15 Software management 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 ACRONYMS AND ABBREVIATIONS 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 GLOSSARY OF TERMS 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ED DATE CHANGE NOTE APPRAISAL AUTHORITY ORIGINATOR

01 041119 C. FAVERO ITAVE P.GHELFI ITAVE

02 050414 ECR 23082 C. FAVERO ITAVE P.GHELFI ITAVE

METRO OMSNRel. 4.4/5.2AOPERATOR’S HANDBOOK

J.MIR – S.MAGGIO

J.MIR – S.MAGGIO

Page 28: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

2

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

LIST OF FIGURES AND TABLES

TABLESTable 1. Software products part numbers 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 2. Software licence part numbers 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3. Software products part numbers 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4. Software licence part numbers 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5. Software products part numbers 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6. Software licence part numbers 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 29: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

3

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

1 INTRODUCTION

1.1 Scope

1.1.1 Document scope

The Introduction Manual present the Craft Terminal main functions and provides a general overview of thedifferent functionalities provided by the ELM–USM of the Craft Terminal for Info Model NE.

1.1.2 Target audience

The Introduction Manual is intended for all users.

The documents that should be read before starting this document are:

– 1320CT Basic Operator’s Handbook

1.2 Reading rules

1.2.1 Menu options

All the manuals describe menus, but not necessarily all the options of these menus. When a menu optionis not detailed in a manual, the information are surely given in another manual.

Page 30: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

4

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

Page 31: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

5

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

2 GENERAL DESCRIPTION OF THE CRAFT TERMINAL

2.1 Introduction

The Craft Terminal is a project in charge of the local management of single network elements, providingITU– compliant Information Model Interface to the Network Element.Multiple NE management up to 32 Network element is possible obtaining a remote Craft Terminalapplication.

The general information of the Craft Terminal are presented in the Basic Craft Terminal Operator’sHandbook, that the operator have to read before this Handbook.

In the Basic Craft Terminal Operator’s Handbook are described all the general description of use, login,navigation, rules, etc, common to all the NE using the same Craft Terminal.

Further, the same handbook contains the detailed description of common operations as “Installation” andcommon screens as “Network Element Synthesis view”.

The Network Element Synthesis view is the first view presented to the operator entering the application.

Starting from this view it is possible login the NE and than enter the EML–USM views.

This Operator’s Handbook deals with the EML–USM views of the Craft Terminal, which directlypermit to manage the Network Element.

The management main functions of the EML–USM are inserted at para. 2.3 on page 10.

A detailed description of the EML–USM screens is given in Section Ne Management of this handbook.

From the Craft Terminal is possible to run other Specific Software applications.These applications are in charge of the ISA–ATM, ISA–PR and ISA–PR_EA (Packet Ring EdgeAggregator) management inside the NE such as cross–connection, Backup and Restore configurationfiles etc.Details information about Specific Application are described in the relevant Operator’s Handbook (seeSection 1 HANDBOOK GUIDE for the code).

The list and part numbers of the SDH software products distributed by Alcatel is inserted in para.2.2 onpage 6.

The Craft Terminal characteristic (computer configuration) are listed in the Basic Craft Terminal Operator’sHandbook.

Page 32: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

6

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

2.2 Alcatel software product and licence delivered to the customer

2.2.1 Software product and licences description

The software products are distributed by Alcatel in a CD–ROM.

In this CD–ROM are contained:

• Software packages for NE management by means of the craft terminal

• Software package of the NE, to be installed in the NE or update the NE (by means of downloadfunction)

The software package used for management permits the dialogue between craft terminal and NE, torealize all the functions of the NES and EML–USM ).

The software package used for updating the NE must be installed on the PC and then downloaded onthe NE, thus following product evolution.

Alcatel typically offers several software licences on the software product.

They are referred both to the Network Element software features and to the Craft Terminal softwarefeatures.

Page 33: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

7

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

2.2.2 1640FOX Software products and licences list and part numbers

Every Software Product is identified by a denomination and a part number, listed on the following table.

Table 1. Software products part numbers

Name ANV Part Number N.B.

SWP 1640FOX SDH R.4.4 CD–ROM 3AL 89846 AA––

Every Software licence is identified by a denomination and a part number, listed on the following table.

Table 2. Software licence part numbers

Name ANV Part Number N.B.

SWL–A POINT 40FOX Rel. 4.4

LICENCE FEE / STM–13AL89684 AJ 1

SWL–B POINT 40FOX Rel. 4.4

LICENCE FEE / STM–13AL 89684 AK 1

SWL–C POINT 40FOX Rel. 4.4

LICENCE FEE / STM–13AL 89684 AL 1

SWL–A POINT 40FOX Rel. 4.4

LICENCE FEE / STM–43AL 89684 AM 1

SWL–B POINT 40FOX Rel. 4.4

LICENCE FEE / STM–43AL 89684 AN 1

SWL–C POINT 40FOX Rel. 4.4

LICENCE FEE / STM–43AL 89684 AP 1

SWL–LCT 40FOX Rel. 4.4 LICENCE FEE 3AL 89684 AQ 2

SWL–RCT 40FOX Rel 4.4 LICENCE FEE 3AL 89684 AR 2

N.B. 1 Licence alternative for Network Element software features:• SWL–A: full functionality set• SWL–B: improved functionality set• SWL–C: basic functionality set

N.B. 2 Licence alternative for Craft Terminal software features:• SWL–LCT: local Craft Terminal functionality• SWL–RCT: remote Craft Terminal functionality

Page 34: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

8

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

2.2.3 1650SMC Software products and licences list and part numbers

Every Software Product is identified by a denomination and a part number, listed on the following table.

Table 3. Software products part numbers

Name ANV Part Number N.B.

SWP 1650SMC SDH R.4.4 CD–ROM 3AL 89849 AA––

Every Software licence is identified by a denomination and a part number, listed on the following table.

Table 4. Software licence part numbers

Name ANV Part Number N.B.

SWL–A POINT 50SMC Rel. 4.4

LICENCE FEE / STM–13AL 89685 AF 1

SWL–B POINT 50SMC Rel. 4.4

LICENCE FEE / STM–13AL 89685 AG 1

SWL–C POINT 50SMC Rel. 4.4

LICENCE FEE / STM–13AL 89685 AH 1

SWL–LCT 50SMC Rel. 4.4 LICENCE FEE 3AL 89685 AJ 2

SWL–RCT 50SMC Rel 4.4 LICENCE FEE 3AL 89685 AK 2

N.B. 1 Licence alternative for Network Element software features:• SWL–A: full functionality set• SWL–B: improved functionality set• SWL–C: basic functionality set

N.B. 2 Licence alternative for Craft Terminal software features:• SWL–LCT: local Craft Terminal functionality• SWL–RCT: remote Craft Terminal functionality

Page 35: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

9

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

2.2.4 1660SM Software products and licences list and part numbers

Every Software Product is identified by a denomination and a part number, listed on the following table.

Table 5. Software products part numbers

Name ANV Part Number N.B.

SWP 1660SM SDH R.4.4 CD–ROM 3AL 89852AA––

SWP 1660SM SDH R.5.2A CD–ROM 3AL 89854 AA––

SWP 1660SM SDH R.5.2B CD–ROM 3AL 89855 AA––

Every Software licence is identified by a denomination and a part number, listed on the following table.

Table 6. Software licence part numbers

Name ANV Part Number N.B.

SWL–A POINT 60SM Rel. 4.4

LICENCE FEE / STM–13AL 89686 AF–– 1

SWL–B POINT 60SM Rel. 4.4

LICENCE FEE / STM–13AL 89686 AG–– 1

SWL–C POINT 60SM Rel. 4.4

LICENCE FEE / STM–13AL 89686 AH–– 1

SWL–LCT 60SM Rel. 4.4 LICENCE FEE 3AL 89686 AJ–– 2

SWL–RCT 60SM Rel. 4.4 LICENCE FEE 3AL 89686 AK–– 2

SWL–A POINT 60SM Rel. 5.2

LICENCE FEE / STM–13AL 89686 AR–– 1

SWL–B POINT 60SM Rel. 5.2

LICENCE FEE / STM–13AL 89686 AS–– 1

SWL–C POINT 60SM Rel. 5.2

LICENCE FEE / STM–13AL 89686 AT–– 1

SWL–LCT 60SM Rel. 5.2 LICENCE FEE 3AL 89686 AU–– 2

SWL–RCT 60SM Rel. 5.2 LICENCE FEE 3AL 89686 AV–– 2

N.B. 1 Licence alternative for Network Element software features:• SWL–A: full functionality set• SWL–B: improved functionality set• SWL–C: basic functionality set

N.B. 2 Licence alternative for Craft Terminal software features:• SWL–LCT: local Craft Terminal functionality• SWL–RCT: remote Craft Terminal functionality

Page 36: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

10

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

2.3 Craft Terminal main functionalities in the NE management

In this chapter, are described the main functionalities of the Craft Terminal, referred to the Network Elementmanagement views, obtained by means EML–USM. The functionalities constitute the heading of each ofthe paragraphs below.

2.3.1 Network Element management supervision

Deals with the NE state and access.

2.3.2 Network Element general configuration

Deals with the general configuration of the equipment.

– Craft Terminal access state (allow or inhibit)

– NE Time management

– Alarms Configuration• Alarm Severity Assignment Profile management,• Allow/Inhibit alarm notification,• Alarm re–synchronization.• Alarm Persistency configuration.

– Restart NE

2.3.3 Security Management

Deals with the security configuration of the equipment.

– Set Manager list

– Set ACD level

2.3.4 External input and output point management

Deals with housekeeping signals input from the external (station alarms) or forwarded (output) towardsthe external.

– Display External points

– Configure External points

Page 37: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

11

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

2.3.5 Diagnosis management

For real time alarm reporting and subsequent fault localization and correction.

– Alarm SurveillanceThe alarms concerning a particular managed entity will be represented in a synthetic way in all theviews concerning the entity.Alarms information are detailed in the Alarms Surveillance Manual

– Abnormal Condition list ( as result of operator’s commands)

– Event log ManagerPermits to have access to the Event Log file.

– Remote Inventory (”upload” and “view” remote inventory)

– Internal Link Monitor

– Data Flow Analizer

2.3.6 Communication and routing management

This deals with the configuration parameters concerning the communication protocols for the local NE,the OS and each other related NE. Different types of protection can be managed:

– Local NE and OS addresses

– NTP configurations

– LAPD, Ethernet, MESA, RAP configurations

– IP Configuration

– Tunneling Configuration

2.3.7 Equipment and board management

Deals with the presentation of the equipment and the hierarchical tree structure, permitting to define thetypes of boards present. The Board view permits to access the Port view.

– Set / modify / remove boards or subracks

– Software information of the selected board.

– Remote Inventory

Page 38: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

12

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

2.3.8 Port management

This permits to set and show the transmission resources (TP) referred only to the port (SDH PDH, HOA,ISA).It is used to check the detailed alarm of each TP and to configure them (many options are the same ofthe Transmission view).

For each port a specific menu is available where various configuration of the specific port can be set, forexample:

– Automatic Laser Shutdown

– MSP protection

– Loopback management and configuration

– Single fiber configuration

– TP Frame Mode Configuration

– Retiming

– Ethernet port configuration

Port view is also the entry point of other “management functions” :

– Performance Monitoring management

– Cross Connection management

For each port are presented:

– the various ITU–T functional blocks (i.e. PPI, RST, VC4).

– details of alarm and state condition

– TP role, connection, etc. information

2.3.9 Protection management

This deals with the protection mechanism that is possible to configure in the NE. Different types ofprotection can be managed:

– Equipment Protection Switching (EPS)

N.B. Not supported by 1640FOX

– Multiple Section Protection (MSP)

– MS–SPRing Protection 2 fibers ( 4 fibers is not operative in current release);

N.B. MS–SPRing Protection is available only for 1660SM

Page 39: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

13

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

2.3.10 Transmission management

This permits to cover the management of the transmission resources, opening the views of all the specificports of the NE (SDH and PDH).It supply an overview of the complete signal flow.For all the ports are presented:

– the various ITU–T functional blocks (i.e. PPI, RST, VC4).

– synthesis of alarm and state condition

– TP role, connection, etc. information

For each port a specific menu is available similar to the Port view where various configuration of thespecific port can be set.

Also Transmission view is than the entry point of other “management functions” .

2.3.11 Cross Connection management

This deals with the connection of all the Termination Point (TP), which are the starting and terminatingpoints of a transmission segment. In this way the multiplex structures are created, managing the trafficflow. Similar operation are made on the OverHead cross connections.

– Create / modify cross connections

– Activate / deactivate / switch cross connections

2.3.12 Performance monitoring management

This function deals with the set up, collect, log and display performance data associated with the managedNE according ITU–T G.826.It consists of a set of functions that evaluate and report on the behavior of theNEs and their effectiveness relating to the communications taking place on the Network.

– Set up the Performance Monitoring thresholds

– Collect and display Performance Monitoring data

– Performance Monitoring history

– Display Maintenance Counter

2.3.13 Synchronization management

Deals with the management of the timing.

– Timing source, SSU, T0, T4,T5 and T6 configuration

– Protection commands

2.3.14 ISA port Configuration

Describes the operations necessary for the ATM/PR_EA/ETH boards and the ATM/PR_EA/ETH TPscreation.

Page 40: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

14

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

2.3.15 Software management

Deals with the manipulation of the software package within NE.

– Software download refers to the NE software, permitting to charge the software in the relevant NEto upgrade the NE software, thus following product evolution, or as a consequence of substitutionwith a spare.

– Back–up and restore on the MIB of the NE.

Page 41: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

15

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

3 ACRONYMS AND ABBREVIATIONS

AIS: Alarm Indication Signal

APS: Automatic Protection Switching (MSP as alternative name)

ASAP: Alarm Severity Assignment Profile

ATM: Asynchronous Transfer Module

CD–ROM: Compact Disc Read Only Memory

CCITT: Telegraph and Telephone International Consultative Committee

CT: Craft Terminal

DCN: Data Communications Network

ECC: Embedded Communication Channels

EML: Element Management Layer

EPS: Equipment Protection Switching

FAD: Functional Access Domain

Gbit/s: Gigabits per second

GNE: Gateway Network Element

HMI: Human Machine Interface

IEEE: Institute of Electrical and Electronics Engineers

IM: Information Manager

IP: Internet Protocol

ISA: Integrated Service Adapter (ISA board are the following unit: ATM, PR_EA, PR and ETHERNET)

Kbit/s: Kilobits per second

LAN: Local Area Network

LVC: Lower Order Virtual Container

MAC: Media Access Control

Mbit/s: Megabits per seconds

MIB: Management Information Base

MS: Multiplex Section

MSP: Multiplex Section Protection

NAD: Network Access Domain

NAP: Network Access Point

Page 42: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

16

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

NE: Network Element

NML: Network Management Layer

NTP: Network Time Protocol

OS: Operation System

PI: Physical Interface

PR_EA: Packet Ring Edge Aggregator

SD: Signal Degrade

SF: Signal Failure

TMN: Telecommunications Management Network

TN: Telecommunications Network

TP: Termination Point

USM: User Service Manager

XC: Cross–Connection

Page 43: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

17

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

4 GLOSSARY OF TERMS

Acknowledgment:When an alarm is taken into account by the application, the operator has to acknowledge it to point outthat he has seen it and that he will react in the right way. During alarm configuration it is possible to seta maximum delay for alarm acknowledgement. The operator can decide whether or not the alarm clearhas to be acknowledged.

Administrator:A user who has access rights to all the Management Domains of the Craft Terminal product. He has accessto the whole network and to all the management functionalities.

Alarm:An alerting indication to a condition that may have an immediate or potentially negative impact on the stateof an equipment or the CT. An alarm is characterized by an alarm begin and an alarm end.

Alarm Severity Assignment Profile:Function allowing the assignment of severities to the alarms depending on their probable causes.

Alarm Status:Identifies the type and severity of an occurring alarm.

Board:A board is part of an NE. They are electronic cards that fit into slots in the NE.

Bridge:The action of transmitting identical traffic on both the working and protection trails.

Bridge Request:A message sent from a tail–end node to the head–end node requesting that the head–end perform abridge of the working channels onto the protection channels.

Bridge Request status:A message sent from a tail–end node to all other nodes within the protection system indicating that thetail–end has requested a bridge.

Bridge&switch node:The node that performs the bridge and switch function for a protection event. Where the bridge and switchis performed on a per AU–4 basis, the node executing a bridge and switch of at least one AU–4 is referredto as a bridge and switch node. Note that with a Transoceanic application, a node in the switching statusmay not be a bridge&switch node, whereas a node in the pass–through state may be a bridge&switchnode. With the Classic application, only a request node (see below) may be a bridge&switch node.

Compact Disk Read Only Memory:Data saving support from which the information can only be read. Is useful for stocking data due to itsavailable memory space.

Craft Terminal:Workstation or Personal computer (PC) from which local address to an NE is possible. It can be used toconfigure or perform monitoring tasks on the NE.

Cross–connectionCross–Connections provide the network with the Routing Capabilities, this is the possibility of routing onesignal to a particular destination.

Digital Communication network:Communication Network in which the transmission of data is done in a digitized format.

Page 44: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

18

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

Embedded Communication Channel:Communication channel used in conjunction with packet commuting networks (X25) to manage distantSDH networks. These communication channels are related to the QECC* protocols.

Element Management Layer:This application is responsible for the configuration and management of Network Elements.

Equipment Protection Switching:Used to provide protection for cards within an equipment to protect traffic in the event of card failure.

Extra traffic:Traffic that is carried over the protection trail when it is not used for the protection of working traffic. Extratraffic is not protected and is preempted when the protection trail is required to protect the working traffic.

Filter:They are related to the alarms or events generated on an NE or internally within the OS itself. They canbe configured by an operator to reject specified types of notifications and limit the processing that is appliedto them.

Flushing:This deals with logs. When a log is flushed, all its records are deleted.

Functional Access Domain:It defines the range of functions which are available to a specified user.

Gigabits per second:Unit that corresponds to the transmission of 109 bits every second.

Gateway Network Element:It is a Network Element devoted to the control, from the OS, of those NEs providing a QECC* interface.To do this it uses a QB3* interface and performs the conversion QB3* ↔ QECC*.

Head End:Node executing the bridge (adjacent along the direction where a failure is present)

Human Machine Interface:It is the graphical user interface application through which the operators interact with the system.

History Report:This function enables operators to get information concerning performances, security or alarms on entitiescomposing the network, or on the network itself. The operator specifies the time period for which herequires the report.

Idle:A node that is not generating, detecting or passing–through bridge requests or bridge request statusinformation.

Intermediate node:The node that is not a request node. It is always in the pass–through state. If such a node executes bridgeand switch of at least one AU–4 it is also a bridge&switch node.

International Telegraph and Telephone Consultative Committee:Standard organization for telecommunications. Now called the ITU–T (International TelecommunicationUnion).

Page 45: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

19

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

Isolated Node:A single node that is isolated from a traffic perspective by ring switches on each of its two spans by itsadjacent nodes.

Kilobits per second:Unit that correspond to the transmission of 103 bits every second.

Line Terminal:A line terminal is the end point of a communication link. it is used to transmit or receive signals. They canundertake signal conversion functions (adapting a signal to two different transmission media) ormultiplexing/demultiplexing functions.

Logs:Logs are files used to store history data concerning the incoming notifications, operator commands andsystem alarms. The size of the log can be configured.

Management Domain:The Craft Terminal product is partitioned into management domains for functional proposes. Eachmanagement domain is associated with functionalities that enable the operators to manage the NEs.

Media Access Control Address:Represents the Level 2 address for Local Area Networks.

Megabits per second:Unit that corresponds to the transmission of 106 bits every second.

Mis–connection:A condition in which traffic destined for a given node is incorrectly routed to another node and no correctiveaction has been taken.

MSSPRing channels:The range of channels that are part of the MSSPRing operation (i.e. the whole of the working andprotection channels).

Multiplexer:Equipment used to combine several signals to produce a single signal at a higher transmission rate andto decompose it back to the smaller rate signals.

Multiplex Section:In general, represents the section containing the multiplexed signals.

Network Access Domain:Defined as a set of Network Elements. NADs are used to define the set of Network Elements that a usercan manage.

Network Element:Either a telecommunication equipment or groups parts of a Telecommunication Network. Havecharacteristics compliant with CCITT recommendations.

Network Management Level:Designates the management functions performed on networks elements assembled in a network.

Notification:Spontaneous data received by the system concerning an NE.

Page 46: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

20

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

Operation System:A system dedicated to the supervision of NEs in a standard way, using protocols and interfaces. it offers tothe operator a set of functions necessary to supervise the NEs. The 1353SH is an Operation System.

Operator:The end–user of the Craft Terminal. He supervises a part of the network that is dependant on his user profile.

Path:According to ITU–T Recommendation G.803, a path is a transport entity (i.e., architectural component)used to transfer information. Nevertheless, this name will be used throughout this document to indicatethe information carried either unidirectionally or bidirectionally between two access points of a ring oneither a path link connection (if the two points are both PDH) or trail segment.

Physical Interface:Electrical or Electrical/Optical transformers that decouples the line signals and adapt the form of signalfor further transmission. This functional block also manages clock extraction, signal loss monitoring andloopback functions.

Port:A physical point at which the Network Element can be attached to a transmission medium. A port is eithera termination point or an origination point.

Protocol request:A message sent by a node to another node via K1/K2 bytes with the purpose of settling a certain behavior.All the K1 request codes represent protocol requests, but not all of them are bridge requests. For example,a SF–R is a bridge request (see ITU–T G841), but LP–S is not: both of them are protocol requests. EvenNR is a protocol request.

Protocol reply:A message sent by a node to another node via K1/K2 bytes with the purpose of acknowledging a receivedprotocol request.

Protection trail:The trail allocated to transport the working traffic during a switch event. When there is a switch event, trafficon the affected working trail is bridged onto the protection trail.

Protection section:The full set of both protection and (lower) unprotected channels in a multiplex section.

Protection semi–section:The part of multiplex section (i.e. the N/2+1..N channels in a 2–fiber STM–N NE) consisting of protectionchannels.

Repeater:Equipment used to regenerate a signal when it has travelled a long distance.

Request node:A node that generates either a protocol request or protocol reply (other than NR!). The pair of nodessending each other protocol request/reply are peer request nodes.

Severity:Linked to alarms, severities indicate the magnitude related to the failure.

Shared protection:A protection architecture using m protection entities shared among n working entities (m:n). The protectionentities may also be used to carry extra traffic when not used for protection.

Page 47: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

21

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

Span:The set of multiplex sections between two adjacent nodes on a ring.

Span Switching:Protection mechanism similar to the MSP that applies only to four–fibre rings where working and protectionchannels are contained in separate fibres and the failure only affects the working channels. During a spanswitch, the working traffic is carried over the protection channel on the same span as failure.

Squelched traffic:An all “1”s signal resulting from the squelching process (insertion of AU–AIS in order to guarantee theconnections)

Switch:The action of selecting traffic from the protection trail rather than the working trail.

Switching Node:The node that performs the bridge or switch function for a protection event. In the case of a multiplexsection switched ring network architecture, this node also performs any necessary squelching ofmisconnected traffic.

Tail End:Node which detects the failure.

Telecommunication Management Network:Defines the concept of interoperable management of TNs. They provide an organized network structureto achieve the interconnection of the different components of the TN and the services to process theinformation.

Telecommunication Network:Describes the network to be managed. Provides the transmission, the transport and the switchingsupports to the interconnected Network Elements.

Terminal Point:Describes either the origin or the termination of a signal in an equipment. Is related to a port.

Thresholding:This is the assignment of a specified value to monitored parameters ( for example BIt Error Rates) that,when exceeded, generate trouble indications.

Unprotected channels:See unprotected channel in ITU–T G841. Each pair of unprotected channels is made up on one in theworking (semi)section plus one in the protection (semi)section.

Unprotected traffic:See unprotected traffic in ITU–T G841.

User Profile:Identifies the functionalities of the Craft Terminal to which a user has access. A finite number of predefineduser profiles is determined by a fixed set of FADs. To give user access to Craft Terminal functionality, theadministrator must assign a profile to a UNIX user account by choosing one among the predefined profilesinstalled with Craft Terminal.

User Service Manager:These are presentation processes used by the Craft Terminal to manage the Human Machine Interfaceand facilitate the interaction with the product.

Page 48: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

22

02

SC.2:INTRODUCTION

/3AL 91670 AA AA

22

22

Working channels:The channels over which working traffic is transported when there are no switch events. An APS systemperforms restoration for the working channels only.

Working traffic:Traffic that is normally carried in a working trail, except in the event of a protection switch.

Working trail:The trail over which working traffic is transported when there is no switch events.

Working section:The full set of both working and (upper) unprotected channels in a multiplex section.

Working semi–section:The part of multiplex section (i.e. the 1..N/2 channels in a 2–fiber STM–N NE) consisting of workingchannels.

Wrapping:Wrapping is the technique that enables the most recent entries in a file to replace the oldest when a fileis full.

END OF DOCUMENT

Page 49: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

1

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

METRO OMSN REL. 4.4/5.2A OPERATOR’S HDBK

TABLE OF CONTENTS

LIST OF FIGURES AND TABLES 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 INTRODUCTION 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Scope 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.1 Document scope 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.2 Target audience 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2 Terminology 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.1 Acronyms and abbreviations 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.2 Glossary of terms 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 GENERAL INTRODUCTION ON VIEWS AND MENUS 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 EML–USM view organization 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Introduction on the EML–USM menu options 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.2.1 Views menu introduction 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.2 Configuration menu introduction 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.3 Diagnosis menu introduction 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.4 Supervision menu introduction 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.5 MS–SPRing menu introduction 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.6 Download menu introduction 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.7 Equipment menu introduction 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.8 Board menu introduction 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.9 Port menu introduction 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.10 EPS menu introduction 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.11 Transmission menu introduction 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.12 Synchronization menu introduction 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.13 External Points menu introduction 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.3 Advices on Navigation principles 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 NE MANAGEMENT SUPERVISION 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 NE management states 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 NE supervision and login 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 NE MANAGEMENT GENERAL CONFIGURATION 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Access state (allow or inhibit NE Craft access) 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.1.1 Switching from the OS to the Craft Terminal access state 50. . . . . . . . . . . . . . . . . . . . . . . . . 4.1.2 Switching from the Craft Terminal access state back to the OS access state 50. . . . . . . .

ED DATE CHANGE NOTE APPRAISAL AUTHORITY ORIGINATOR

01 041119 C. FAVERO ITAVE P.GHELFI ITAVE

02 050414 ECR 23082 C. FAVERO ITAVE P.GHELFI ITAVE

METRO OMSNRel. 4.4/5.2AOPERATOR’S HANDBOOK

J. MIR – S. MAGGIO

J. MIR – S. MAGGIO

Page 50: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

2

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.2 NE Time management 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3 Alarm Configuration 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.3.1 Procedure to modify an ASAP 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.2 Alarm Severity Assignment Profile Management (ASAP) 53. . . . . . . . . . . . . . . . . . . . . . . . . 4.3.3 Set SdhNE Alarms Severities 63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.4 Allow/Inhibit Alarms Notifications 64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.5 Alarms re–synchronization 65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.6 Alarms Persistency Configuration 66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.4 Restart NE 67. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5 SECURITY MANAGEMENT 69. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 Set Manager list 69. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 Set ACD level 70. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6 EXTERNAL INPUT AND OUTPUT POINTS MANAGEMENT 71. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1 Displaying external points 72. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6.1.1 Expanding or reducing external points list. 74. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2 External points configuration 75. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7 DIAGNOSIS MANAGEMENT 79. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1 Alarms surveillance 79. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2 Abnormal Condition List 81. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.3 Internal Link Monitor 83. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.4 Log Browsing 85. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5 Remote Inventory 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7.5.1 Upload remote Inventory 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5.2 View Remote Inventory 87. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8 COMMUNICATION AND ROUTING MANAGEMENT 89. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1 Overview on Communication and Routing Domain 89. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8.1.1 OSI Protocol on QB3/Qecc 89. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1.2 OSI Partitioning into separate Routing Domains 90. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1.3 IP over OSI tunneling for ISA board 91. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1.4 OSI over IP tunneling on QB3 91. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8.2 Communication and routing views 93. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.3 Local Configuration 95. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.4 OS Configuration 97. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.5 NTP Server Configuration 98. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.6 LAPD Configuration 99. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.7 Ethernet Configuration 102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.8 Reachable Address Prefixes Configuration 104. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.9 Manual ES Adjacencies table Configuration 105. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.10 IP Configuration 106. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8.10.1 IP routing configuration for ISA boards management 106. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.11 IP Static Routing Configuration 107. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.12 OSPF Area Table Configuration 108. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.13 IP Address Configuration of Point–to–Point Interfaces 109. . . . . . . . . . . . . . . . . . . . . . . . . . 8.14 ISA board IP Address 110. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.15 OSI over IP 111. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.16 IP over OSI 112. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9 EQUIPMENT MANAGEMENT 115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1 Introduction and navigation 115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.2 Set and change or remove board/subrack 122. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.3 Connect Fan to CONGI board 126. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 51: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

3

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

9.4 Board administrative state 128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.4.1 Setting a board in service 128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.4.2 Setting a board out of service 128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.4.3 Consulting a Board’s Administrative state 128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9.5 Software description 129. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.6 Remote Inventory 130. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.7 Show supporting equipment 132. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10 BOARD VIEW 133. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1 Introduction 133. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.2 Board View Menu 135. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10.2.1 Port Access 136. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.2.2 Change Physical Interface 137. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.2.3 Show Supporting equipment 138. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11 PORT VIEW 139. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 Introduction 139. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.2 Port View: elements on the TP 141. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.3 Port View Menu 142. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.4 Port Mode Configuration 144. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.5 Set Retiming 146. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.6 AU4 Concatenation 148. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.7 Physical Media option menu 151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11.7.1 Automatic Laser Shutdown Configuration 152. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.7.2 Show Optical Configuration 156. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.7.3 Single Fiber Configuration 157. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.7.4 Ms Configuration 159. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.7.5 Line Length Configuration 160. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.7.6 Ethernet Port Configuration 161. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.7.7 Ethernet Mapping Protocol 164. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.7.8 Control Path Activation 165. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.7.9 LCAS Configuration 167. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11.8 TP Frame Mode Configuration 170. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.9 Show Supporting Board 173. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.10 Navigate to Transmission View 174. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.11 Navigate to Monitoring View 175. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11.11.1 Navigate to HOA Port View 176. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12 EQUIPMENT PROTECTION MANAGEMENT (EPS) 177. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.1 Introduction 177. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.2 Management: consulting and modifying EPS 178. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.3 Configuration: revertive and WTR for EPS 185. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.4 Switching EPS 187. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.5 EPS Overview 188. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13 MULTIPLEX SECTION PROTECTION MANAGEMENT (MSP) 193. . . . . . . . . . . . . . . . . . . . . . . . . . 13.1 Architecture types 193. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.2 MSP Options Introduction 194. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.3 MSP Create 195. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.4 MSP Management 199. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13.4.1 MSP modification 200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.5 MSP Delete 201. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.6 Display of Protection State 202. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.7 MSP Commands 204. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.8 MSP overview 206. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 52: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

4

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14 TRANSMISSION VIEW 211. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.1 Overview 211. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.2 View elements 212. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.3 View Layout 213. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.3.1 View Description 213. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.3.2 Number of TPs Displayed in Transmission View 214. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.3.3 Naming TPs 214. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.3.4 Dynamic View Behavior 214. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.4 Transmission view access and menu 215. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.5 Add TP 217. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.5.1 TP Search 217. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.6 TP Configuration 227. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.6.1 High Order TP Configuration 227. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.6.2 J0 Section Trace management 230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.6.3 Low Order TP Configuration 231. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.7 TP Threshold Configuration 234. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.8 Terminate/Disterminate TP 235. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.8.1 Terminate TP 235. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.8.2 Disterminate TP 235. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.9 Monitoring Operations 236. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.9.1 Creation/Deletion 237. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.9.2 Configuration 239. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.10 Structure TPs 241. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.11 Loopback 242. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.11.1 Loopback Configuration 242. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.11.2 Loopback Management 245. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.12 Physical Media 247. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.12.1 Set Domain 248. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14.13 Navigation Commands 249. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.13.1 Expand 249. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.13.2 Hide 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.13.3 Show Supported Board 251. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.13.4 Navigate to Port View 252. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15 CROSS-CONNECTION MANAGEMENT 253. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.1 Introduction 253. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15.1.1 Overview 253. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.1.2 Multiplex Structures for SDH 254. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.1.3 Definition of Termination Points (TP) 257. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.1.4 Mapping Tables: TP Names 261. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.1.5 Cross-Connection Types 262. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.1.6 Cross-Connection Protection 264. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15.2 Operative Sequence to execute Cross-Connections 266. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.3 Cross-Connections management 270. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15.3.1 Search Criteria 272. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.3.2 Cross-Connection List 274. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.3.3 Actions available 276. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15.4 Create/Modify Cross-Connections 277. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.4.1 Cross-Connection Parameters 278. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.4.2 Create a Cross-Connection 283. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.4.3 Modify a Cross-Connection 289. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15.5 Activate/Deactivate/Delete Cross-Connections 292. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.5.1 Activate a Cross-Connection 292. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.5.2 Deactivate a Cross-Connection 292. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 53: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

5

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.5.3 Delete a Cross-Connection 292. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.6 Split and Join Cross-Connections 293. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15.6.1 Split a Cross-Connection 293. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.6.2 Join Two Cross-Connections 295. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15.7 Protection Switching 296. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.8 Print 298. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.9 Show Cross-Connected TPs 299. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16 OVERHEAD MANAGEMENT 301. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.1 Introduction 301. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.2 OH Connection overview 302. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.3 Overhead views 303. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.4 OH Cross Connection 304. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.5 OH TP creation 309. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.6 OH TP deleting 310. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.7 OH Phone Parameters 311. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17 PERFORMANCE MONITORING 313. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.1 Introduction 313. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2 Performance Monitoring on SDH port 314. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17.2.1 Overview 314. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2.2 Supported Performance Counters 314. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2.3 Far End (FE) and Near End (NE) Performance Counting 316. . . . . . . . . . . . . . . . . . . . . . . . 17.2.4 Bidirectional counting (24 h Bi) for QoS 316. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2.5 End to End (e–e 24h) Performance Counting 317. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2.6 Performance Monitoring on AU–PJE 317. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2.7 Tandem Connection Termination (TCT) and Monitoring (TCM) 318. . . . . . . . . . . . . . . . . . . 17.2.8 Performance Monitoring on 2 Mbit/s ISDN–PRA 318. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2.9 Performance Data Collection 318. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2.10 Data Collection 319. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2.11 Performance Monitoring History 319. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.2.12 Thresholds 320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17.3 Performance Monitoring on ETHRNET port 321. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.3.1 Overview 322. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.3.2 Ethernet physical interface counters 322. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.3.3 Aggregate counter 323. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.3.4 Flow counter 324. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17.4 Configuration (SDH port) 325. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.5 Display Current Data (SDH port) 330. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.6 Display History Data (SDH port) 333. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.7 PM Threshold Table Selection (SDH port) 335. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.8 PM Threshold Table Create / Modification / Display (SDH port) 339. . . . . . . . . . . . . . . . . . .

17.8.1 Creation 339. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.8.2 Modification 341. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.8.3 Display 341. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17.9 Configuration (Ethernet port) 343. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.10 Display current Data (Ethernet port) 344. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.11 Display history Data (Ethernet port) 348. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.12 PM overview 350. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18 SYNCHRONIZATION MANAGEMENT 355. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.1 Introduction 355. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.2 Synchronization Management 357. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18.2.1 Displaying the Synchronization View 357. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 54: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

6

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.2 Synchronization View 358. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.2.3 Timing Source Configuration 361. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.2.4 Synchronization Protection Commands 364. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.2.5 Synchronization Configuration for T0/T4/T5 and T4 squelch criteria 365. . . . . . . . . . . . . . . 18.2.6 SSU Configuration 368. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.2.7 Remove Timing Reference 369. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.2.8 Change T4 <–> T5 370. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.2.9 Change 2MHz –>2Mbit 372. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.2.10 Set and Remove T0 Equal T4 374. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.2.11 Transmission of SSM Quality Configuration 375. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.2.12 Show Timing Source 376. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19 MS–SPRING MANAGEMENT 377. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.1 MS–SPRING introduction 377. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.2 MS–SPRING connection configuration advices 378. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19.2.1 2–Fiber MS–SPRING connection configuration advices 378. . . . . . . . . . . . . . . . . . . . . . . . . 19.3 Operative sequence to configure MS–SPRING 379. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19.3.1 Operative sequence to configure 2–Fiber MS–SPRING 379. . . . . . . . . . . . . . . . . . . . . . . . . 19.4 MS–SPRING Management 380. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19.4.1 MS–SPRing Main Configuration 381. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.4.2 Squelching Table with 2 fiber Terrestrial applications 387. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.4.3 Activate, Deactivate and Delete commands 393. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19.5 MS–SPRING Protection Status and Commands for 2 fiber terrestrial application 394. . 19.5.1 2F MS–SPRing protection commands 394. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.5.2 External commands (2F) 396. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.5.3 2F MS–SPRing dual protection commands 404. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.5.4 2F Protection Status Visualization 409. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20 ISA PORT CONFIGURATION 427. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20.1 Introduction 427. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20.2 ISA board TTPs creation 428. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20.2.1 ISA–ATM boards 428. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20.2.2 ISA– PR_EA board 430. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20.2.3 10/100 Mbit/s fast ETHERNET board 432. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20.2.4 Gigabit/s ETHERNET board 434. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20.2.5 ISA –ES boards 435. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21 SOFTWARE MANAGEMENT 439. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.1 Generalities and descriptions 439. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21.1.1 Naming Conventions 440. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.2 Software download operative sequence 441. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21.2.1 Software Download upgrade 441. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.3 Software Download Manager menu 442. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.4 Init download 443. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.5 SW package Activation and Units information 445. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.6 Mib management 447. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 55: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

7

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LIST OF FIGURES AND TABLES

FIGURESFigure 1. 1640FOX EML–USM main view organization. 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2. 1650SMC EML–USM main view organization. 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3. 1660SM EML–USM main view organization. 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4. Menu options flow chart – 1 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 5. Menu options flow chart – 2 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 6. Menu options flow chart – 3 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 7. Menu options flow chart – 4 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 8. Menu options flow chart – 5 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 9. Menu options flow chart – 6 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 10. Menu options flow chart – 7 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 11. 1640FOX: EML–USM Main view. 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 12. 1650SMC: EML–USM Main view. 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 13. 1660SM: EML–USM Main view. 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 14. NE management: setting the access state. 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 15. Consulting and/or setting the local NE time. 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 16. NE Time dialogue box. 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 17. Configuring Alarm Severity Assignment Profile. 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 18. ASAPs Management dialogue box. 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 19. ASAP Edition dialogue box. 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 20. Set ASAP dialogue box (example) 57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 21. Clipboard dialog layout 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 22. Tp search dialog with support for ASAP filtering 60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 23. Equipment search dialog with ASAP filtering support 61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 24. Search for resources assigned to ASAP 62. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 25. Set SdhNE Alarms Severities 63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 26. Inhibit alarm notification 64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 27. Allow alarm notifications 64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 28. Alarm re–synchronization 65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 29. Alarm Persistency Time configuration window 66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 30. Restart NE confirmation 67. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 31. Set Manager list 69. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 32. Set ACD level 70. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 33. Opening the external points view. 72. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 34. External points view (example) 73. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 35. Expanding or reducing the external points list. 74. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 36. Configuring external points. 75. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 37. External input point configuration dialogue box (example) 75. . . . . . . . . . . . . . . . . . . . . . . . . Figure 38. External output point configuration dialogue box (MANUAL). 76. . . . . . . . . . . . . . . . . . . . . . Figure 39. External output point configuration dialogue box (FLEXIBLE) 76. . . . . . . . . . . . . . . . . . . . . . Figure 40. Alarm Surveillance 79. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 41. Alarm Surveillance (example) 80. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 42. Abnormal condition menu option 81. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 43. Example of abnormal condition list 81. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 44. Example of loopback dialog window management 82. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 45. Internal Link Monitor (1660SM example) 84. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 46. Log Browsing option in Network Element context view 85. . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 47. Remote Inventory confirmation request 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 48. Remote Inventory completed 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 49. View Remote Inventory (example) 87. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 50. Routing subdomain organization example 90. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 56: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

8

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 51. OSI over IP tunneling on QB3 92. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 52. Comm/Routing options 94. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 53. Local Configuration 96. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 54. OS Configuration 97. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 55. NTP Server Configuration 98. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 56. LAPD Configuration dialog (example) 100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 57. Creation LAPD Interface 101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 58. Confirmation to change LAPD Role 101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 59. Ethernet Configuration 103. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 60. Ethernet Configuration – L2 only parameter 103. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 61. RAP Configuration 104. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 62. MESA Configuration 105. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 63. IP Static Routing Configuration (example) 107. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 64. OSPF Area Table Configuration (example) 108. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 65. IP Address Configuration of Point–to–Point Interfaces (example) 109. . . . . . . . . . . . . . . . . . . Figure 66. ISA Board IP Address (example) 110. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 67. OSI over IP Tunneling configuration (example) 111. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 68. IP over OSI Tunneling configuration (example) 113. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 69. Equipment Overview – 1650SMC and 1660SM “Subrack“ level 117. . . . . . . . . . . . . . . . . . . . Figure 70. Equipment Overview – 1650SMC and 1660SM “Rack” level 118. . . . . . . . . . . . . . . . . . . . . . . Figure 71. Equipment Overview – 1650SMC and 1660SM “Equipment level” 119. . . . . . . . . . . . . . . . . . Figure 72. Equipment Overview – 1640FOX“Rack” level 119. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 73. Equipment Overview – 1640FOX “Subrack“ level 120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 74. Equipment Overview – 1640FOX “Equipment level” 120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 75. Equipment menu (example) 121. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 76. The list of different boards/subrack relative to an NE slot (examples) 123. . . . . . . . . . . . . . . Figure 77. Connect FAN to CONGI 126. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 78. Remove FAN connection from CONGI 127. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 79. Consulting a board’s administrative state (example) 128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 80. Software Description dialogue box (example) 129. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 81. Remote Inventory (example) 130. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 82. Select Printer 131. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 83. Select Output Format for file 131. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 84. Equipment Overview – Subrack level (example) 132. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 85. Equipment view: select the SDH port on a board (example) 133. . . . . . . . . . . . . . . . . . . . . . . Figure 86. Example of a Board View 134. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 87. Examples of a Ports identification and relevant alarm synthesis 134. . . . . . . . . . . . . . . . . . . Figure 88. Board menu options 135. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 89. After “Port Access” selection (example) 136. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 90. Change Physical Interface (example) 137. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 91. Subrack level (example) 138. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 92. Example of a Port View (example) 140. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 93. Termination TP box (example) 141. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 94. G.783 Adaptation TP box. 141. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 95. Examples of port menu options (SDH, PDH and ATM/GBIT ETHERNET port) 143. . . . . . . Figure 96. Port mode configuration pull–down menu 144. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 97. Port Mode overview 145. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 98. Set Retiming enable (before) 146. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 99. Set Retiming enable (after) 147. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 100. AU4 concatenate/deconcatenate commands 149. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 101. Example of a concatenated AU4 transmission view 150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 102. Example of a concatenated AU4c 150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 103. Physical media menu (SDH port example) 151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 104. Automatic Laser Shutdown Management 152. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 57: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

9

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 105. Automatic Laser Shutdown Management (after ALS Function delete) 153. . . . . . . . . . . . . . Figure 106. ALS and Laser current state (example) 154. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 107. Visualizing a port optical parameters (example) 156. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 108. Bidirectional Transmission on a single fiber 157. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 109. Single Fiber Configuration View 158. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 110. Ms Configuration 159. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 111. PDH Line Length Configuration View 160. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 112. Ethernet Port Configuration options (fast ethernet example) 161. . . . . . . . . . . . . . . . . . . . . Figure 113. Ethernet Port Configuration menu 161. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 114. Information dialog 162. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 115. Gigabit Ethernet port view (example) 163. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 116. Ethernet Mapping Protocol (EXAMPLE) 164. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 117. Control Path Activation:Individual Path mode 165. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 118. Control Path Activation:Range Path mode 166. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 119. LCAS configuation pull–down menu 167. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 120. LCAS Configuration 167. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 121. LCAS Monitoring 168. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 122. TP Frame Mode Configuration 170. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 123. Board View Example. 173. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 124. After “Navigate to Transmission view” selection (example) 174. . . . . . . . . . . . . . . . . . . . . . . Figure 125. View of Monitoring Operations (example) 175. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 126. Navigate to HOA Port 176. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 127. Consulting EPS 178. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 128. EPS Management dialogue box (example) 178. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 129. EPS: board selection (example) 183. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 130. EPS: choose protected (example) 183. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 131. EPS functional state from protected active board view 184. . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 132. EPS functional state from protecting active board view 184. . . . . . . . . . . . . . . . . . . . . . . . . . Figure 133. Configure EPS 185. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 134. EPS Management dialogue box (example) 185. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 135. Switching EPS 187. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 136. EPS Switch dialogue box (example) 187. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 137. EPS overview 188. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 138. EPS overview after Search (Example) 189. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 139. Subrack view after “Open Subrack View” command (example) 192. . . . . . . . . . . . . . . . . . . Figure 140. Board view after “Open Board View” command (example) 192. . . . . . . . . . . . . . . . . . . . . . . Figure 141. MSP Create Option 195. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 142. MSP Schema Creation 195. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 143. MSP schema creation Port dialog 196. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 144. TP Search (example) 197. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 145. MSP 1+1 standard protection schema (example) 198. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 146. MSP N:1 standard protection schema (example) 198. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 147. MSP Management Option 199. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 148. MSP Management View (example) 200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 149. MSP Delete option 201. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 150. MSP Schema Deletion (example) 201. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 151. MSP Protection Status Examples 203. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 152. MSP Commands option 204. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 153. MSP Commands (example) 205. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 154. MSP overview 206. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 155. MSP overview after Search (Example) 207. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 156. Port view after “Open Port View” command (example) 209. . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 157. Symbols Used in Transmission View 212. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 158. Transmission View Area (example) 213. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 58: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

10

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 159. Transmission menu options 216. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 160. TP Search Dialog, Initial State 217. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 161. Information Window (example) 218. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 162. TP Search Dialog with Various TP Selections 218. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 163. TP Search Dialog with Status Information Displayed 219. . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 164. Symbols in TP Search 219. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 165. TP search window: Show Monitoring details (example) 220. . . . . . . . . . . . . . . . . . . . . . . . . . Figure 166. TP search window: Show Performance Monitoring details (example) 220. . . . . . . . . . . . . . Figure 167. Board History Check List 221. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 168. TP Search: ASAP search filtering 222. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 169. TP Search Dialog with Different Filtering Options 224. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 170. “Information...” Dialog for Search Process 224. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 171. Print to Printer 225. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 172. Print to File 225. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 173. Example Printout 226. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 174. High Order TP Configuration 227. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 175. J1 hexadecimal editor (example) 228. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 176. J0 Configuration 230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 177. J0 hexadecimal editor 230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 178. Low Order TP Configuration 231. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 179. J2 hexadecimal editor 232. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 180. Degraded Signal Threshold selection (example) 234. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 181. Monitoring Operations Creation/Deletion 237. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 182. Display of POM and TCM in Port View (example) 238. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 183. Display of POM and TCM/TCT in Port View (example) 238. . . . . . . . . . . . . . . . . . . . . . . . . . Figure 184. Monitor Configuration 239. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 185. Loopback configurations 242. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 186. Port Loopbacks View 244. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 187. Loopback Management 245. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 188. Set Domain 248. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 189. Board View (example) 251. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 190. Port View 252. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 191. SDH Multiplex Structure according to ITU-T G.707 255. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 192. Frame Construction within the Synchronous Digital Hierarchy 256. . . . . . . . . . . . . . . . . . . . Figure 193. SDH Transport Level Diagram 259. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 194. PDH Transport Level Diagram 260. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 195. Unidirectional Connection 262. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 196. Bidirectional Connection 262. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 197. Example of Broadcast Connection with Three Legs 263. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 198. Protected Unidirectional Connection 264. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 199. Bidirectional Connection – Input Protected 264. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 200. Protected Broadcast 265. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 201. Drop and Continue – Normal 265. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 202. Cross connection management cascade menu 270. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 203. Cross-Connection Management Dialog (Initial State) 273. . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 204. Cross-Connection Management Dialog (After Search) 275. . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 205. Protection Criteria 279. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 206. Cross-Connection Icons 282. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 207. Creation of a Unidirectional, Non-Protected Cross-Connection 282. . . . . . . . . . . . . . . . . . . . Figure 208. Create a Bidirectional Protected Cross-Connection (example) 284. . . . . . . . . . . . . . . . . . . . Figure 209. Search for Cross-Connection Output (example) 286. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 210. Create an Unprotected Broadcast Cross-Connection (example) 287. . . . . . . . . . . . . . . . . . Figure 211. Create a Protected Broadcast Cross-Connection (example) 288. . . . . . . . . . . . . . . . . . . . . . Figure 212. Unprotect a Bidirectional Cross-Connection (example) 290. . . . . . . . . . . . . . . . . . . . . . . . . .

Page 59: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

11

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 213. Protect one Leg of a Broadcast Connection (example) 291. . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 214. Split/Join Unprotected Bidirectional Cross-Connection 293. . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 215. Split/Join to Protected Bidirectional Cross-Connection 294. . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 216. Protection Actions Dialog 296. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 217. Select Printer 298. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 218. Select Output Format 298. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 219. Show Cross Connected VC4 of an AU4 300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 220. Overhead options 303. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 221. Cross Connection Management for OverHead dialog (example) 304. . . . . . . . . . . . . . . . . . Figure 222. Main Cross-Connection for OverHead dialog 304. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 223. OH TP creation 309. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 224. OH Search TP for creation (example) 309. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 225. OH TP deleting 310. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 226. Phone Parameters dialog window (example) 311. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 227. Far End Performance Monitoring Principles 316. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 228. Counter directionality: network centric view 321. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 229. Counter subdivision 322. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 230. Ethernet Aggregate counter 324. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 231. Ethernet Flow counter 324. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 232. PM Configuration Dialog (example) 327. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 233. PM question dialog box (example) 327. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 234. Current PM Data Dialog (example) 332. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 235. PM History Data Dialog (example) 334. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 236. PM Threshold Table Select 336. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 237. Create PM Threshold Table 340. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 238. Modify PM Threshold Table 342. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 239. Create Ethernet counter 343. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 240. Display Current Data 344. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 241. Display Current Data example (Interface counters) 345. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 242. Display Current Data example (Flow counters) 346. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 243. Display Current Data (Aggregate counters) 347. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 244. Display History Data 349. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 245. PM Overview menu 350. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 246. PM overview window 351. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 247. PM overview–Tp search windows interworking 353. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 248. Internal organization of the SETS. 355. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 249. Obtaining the synchronization view. 357. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 250. Synchronization View Example 358. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 251. Synchronization Menu 361. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 252. Timing source configuration for cross–connect equipments 362. . . . . . . . . . . . . . . . . . . . . . Figure 253. TP Synch. source search (example) 363. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 254. Lockout, Force and Manual commands 364. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 255. Configuring the T0 or T4 SSM algorithm and the squelch criteria 366. . . . . . . . . . . . . . . . . . Figure 256. T5 output SSN bits configuration 367. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 257. SSU Configuration 368. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 258. Synchronization source removing (example) 369. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 259. Synchronization source removing confirmation 369. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 260. Change T4 <–> T5 menu (example) 370. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 261. Change T4 <–> T5 confirmation message 370. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 262. Change T4 <–> T5: command execution (example) 371. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 263. Change 2MHz –>2Mbit menu (example) 372. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 264. Change 2MHz –>2Mbit confirmation message 372. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 265. Change 2MHz –>2Mbit: command execution (example) 373. . . . . . . . . . . . . . . . . . . . . . . . . Figure 266. T4 equal T0 setting (example) 374. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 60: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

12

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 267. Transmission SSM Quality (example) 375. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 268. Show Timing Source (example with T2 reference source) 376. . . . . . . . . . . . . . . . . . . . . . . . Figure 269. Display MS–SPRing pull down menu 380. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 270. MS–SPRing Management dialogue box. 381. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 271. Creation Schema dialog box. 382. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 272. Activated MS–SPRing Management 383. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 273. Set scheme name 383. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 274. Node Id and associated ring node position. 384. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 275. Ring map configuration 385. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 276. WTR dialog box. 386. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 277. Example of error message 387. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 278. Squelching table 387. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 279. Example of a ring traffic 388. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 280. Connections of the ring of Figure 279. 388. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 281. Squelching table of Node A, West side. 389. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 282. Squelching table of Node A, East side. 389. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 283. Squelching table of Node B, West side. 390. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 284. Squelching table of Node B, East side. 390. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 285. Squelching table of Node C, West side. 391. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 286. Squelching table of Node C, East side. 391. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 287. Squelching table of Node D, West side. 392. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 288. Squelching table of Node D, East side. 392. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 289. Confirmation message 393. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 290. Protection states and commands ”Idle” status (2F) 394. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 291. Ring Protection (2F) 395. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 292. Lockout commands (2F) 396. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 293. Protection and working channels where the lockout command can be activated (2F) 396Figure 294. Tail–end / Head–end association 397. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 295. Tail–end / head–end protection with a lockout working and a one direction ring failure (2F)398Figure 296. Ring protection with a lockout and a ring failure (2F) 399. . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 297. Lockout command and non–served failures (2F) 400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 298. Forced and Manual commands (2F) 401. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 299. Manual and Force Ring command (2F) 401. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 300. Ring Protection with Force and Manual commands (2F) 402. . . . . . . . . . . . . . . . . . . . . . . . . Figure 301. Automatic protection Bridge/Switch (2F) 403. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 302. Example of confirmation dialog box 403. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 303. Clear WTR command (2F) 403. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 304. Ring network reference scheme (2F) 405. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 305. Examples of Double ring failure 406. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 306. 2F Automatic protection (tail/head) for double ring failure visualization 407. . . . . . . . . . . . . Figure 307. Tail / head dual “Events” Protection table (2F) 408. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 308. Manual command applied at the “Reference Point” ring network Figure 305. 410. . . . . . Figure 309. Visualization of the Forced / Manual protection Statuses (2F) 411. . . . . . . . . . . . . . . . . . . . . Figure 310. Visualization of the Lockout command Statuses (2F) 412. . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 311. Visualization of Automatic Protection Statuses (2F) 413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 312. Protection status with double ring failure (reference point––SS–AN) 414. . . . . . . . . . . . . . . Figure 313. Protection status with double ring failure (reference point––SS–RN) 415. . . . . . . . . . . . . . . Figure 314. Protection status with double ring failure (reference point––OS–AN) 416. . . . . . . . . . . . . . . Figure 315. Protection status with double ring failure (reference point––OS–AN) recovering to “idle” . . 417Figure 316. Double manual ring command (reference point––SS–AN) 418. . . . . . . . . . . . . . . . . . . . . . . . Figure 317. Double manual ring command (reference point––OS–AN) 419. . . . . . . . . . . . . . . . . . . . . . . Figure 318. Manual ring and Lockout Protection (reference point––SS–SN) 420. . . . . . . . . . . . . . . . . .

Page 61: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

13

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 319. Manual ring and Lockout Protection (reference point––SS–RN) 421. . . . . . . . . . . . . . . . . . Figure 320. Automatic working ring and Manual Ring (reference point––OS–AN) 422. . . . . . . . . . . . . Figure 321. Automatic working ring and Force Ring (reference point––SS–AN) 423. . . . . . . . . . . . . . . Figure 322. Automatic working ring and Lockout working Ring (reference point––SS–SN) 424. . . . . Figure 323. Automatic working ring and Lockout Protection (reference point––OS–RN) 425. . . . . . . . Figure 324. ATM TPs creation 428. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 325. Navigate to ATM port view (example) 429. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 326. PREA4ETH: example of TPs creation 430. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 327. MPLS port view exaple 431. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 328. Example of Fast Ethernet (ETH–MB) TPs creation 432. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 329. Control Path activation window (example) 433. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 330. ETHERNET port view example 433. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 331. Example of Ethernet Switch (ES1–8FE) TPs creation (EMPTY FIELDS) 435. . . . . . . . . . Figure 332. Example of Ethernet Switch (ES1–8FE) TPs creation (WITH DEFEINED TPS) 436. . . . Figure 333. Control Path activation window (example) 437. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 334. ETHERNET SWITCH port view example 438. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 335. Software Download general principle 439. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 336. Equipment view (example) 442. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 337. Download menu 442. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 338. SW Downloading dialogue box example 443. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 339. Software download in progress (example) 444. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 340. Software Package Information dialogue box (example) 445. . . . . . . . . . . . . . . . . . . . . . . . . . Figure 341. Detail software package (example) 446. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 342. NE MIB management (example) 447. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TABLESTable 1. SDH NE alarms 63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 2. STM–N port and AU4 concatenation supported by each equipment 148. . . . . . . . . . . . . . . . . . Table 3. MSP commands and Auto–switch protection priority 205. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4. Default value for C2/V5 Signal Label 228. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5. Supported loopback 243. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6. PDH TPs 261. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7. SDH TPs 261. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 8. Optional and Mandatory Configurable Parameters for Cross-Connection Creation 280. . . . . . Table 9. Modifiable Parameters 289. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 10. 1660SM Threshold table entities association 337. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 11. 1640FOX and 1650SMC Threshold table entities association 337. . . . . . . . . . . . . . . . . . . . . . . Table 12. Maximum Performance Parameter Values 341. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 62: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

14

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 63: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

15

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

1 INTRODUCTION

1.1 Scope

1.1.1 Document scope

The aim of this document is to help the operator understand, configure and manipulate Network Elements(NEs) easily, using the Craft Terminal (CT). The different functionalities related to the equipment views,the menu items and the different actions that can be undertaken from these views are described in detail.

Unless otherwise specified, the menu and the relevant description in the followingchapters are intended as applicable to all the three Network Elements (1640FOX,1650SMC, 1660SM).

In many screen of this handbook the release number is not indicated, while it is insteadpresent in the real screen displayed to the operator.This is due to the fact that the same screen is associated to the different releases.Sometimes the release number reported is only for example.

The most part of the screen of this handbook are referred to 1660SM menu because it isthe equipment with the complete set of features, so it has been choosed like referenceexample.Anyway similar screen are presented for 1650SMC and 1640FOX so can be apply tothem, the same description of 1660SM .

1.1.2 Target audience

This document is intended for the operators whose role is to manage the Network Elements.

The documents that should be read before starting this document are:

– 1320CT Basic Operator’s Handbook

The documents of this Handbook that should be read before starting this document are:

– Introduction manual

1.2 Terminology

1.2.1 Acronyms and abbreviations

Refer to the Section Introduction manual.

1.2.2 Glossary of terms

Refer to the Section Introduction manual.

Page 64: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

16

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 65: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

17

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

2 GENERAL INTRODUCTION ON VIEWS AND MENUS

In this chapter the organization of the EML–USM screen, presented after the NE login, is described.

First is introduced the view organization, than the accessible menu options are listed.

At the end some further advice are given for Navigation principles.

2.1 EML–USM view organization

The EML–USM view is the first window presented to the operator after the login.

The first view is different according to the Equipment type but the navigation principles are the same forall; Figure 1. , Figure 2. , and Figure 3. show some examples.

EML–USM view contains the following fields, that provide you with information needed to manage the NE:

• Severity alarm synthesis,• Domain alarm synthesis,• Management status control panel• View title,• View area• Message/state area

The Menu bar and the View area contained in the same NE view permits to performs all the configurationand supervision and display the specific selected item.

The view organization is detailed in the Basic Craft Terminal Operator Handbook to which refer for thedescription, except for the following information, that differs according the NE type:

– Domain alarm synthesisThe different alarm domain type in which can be subdivided the NE are: Synchronization, ExternalPoint, Equipment, Transmission.

Information about the alarms and status is given in the Maintenance section of this handbook.

Page 66: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

18

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Severity alarmssynthesis

Message/state area

View area

View title

Domain alarms synthesis

Management states control panel

Menu bar

LCA

Figure 1. 1640FOX EML–USM main view organization.

Page 67: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

19

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Severity alarmssynthesis

Message/state area

View area

View title

Domain alarm synthesis

Management states control panel

Menu bar

LCA

Figure 2. 1650SMC EML–USM main view organization.

Page 68: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

20

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Severity alarmssynthesis

Message/state area

View area

View title

Domain alarm synthesis

Management states control panel

Menu bar

LCA

Figure 3. 1660SM EML–USM main view organization.

Page 69: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

21

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

2.2 Introduction on the EML–USM menu options

The menu bar allows to perform configuration and supervision functions on the Network Element.

This paragraph list all the menu options and then more details on the relevant contained entries.

For each of them the relevant operative function are briefly introduced and it is referred the paragraphswhere it is detailed or the introduction to the options of each menu inserted in next paragraphs of thischapter.

The flow charts from Figure 4. summarize the menu options.

From chapter 3 on details and operative information on the all the views are given. They are not presentedaccording the menu option sequence but according a functional subdivision.

In the menu bar there are permanent menu items always displayed. Staring from the left , the menus are:

– Permanent Menus

• Views (first column). See para.2.2.1 on page 23.

To navigate among the NE views (Equipment, External Point, Transmission etc. ) .

• Configuration (second column). See para.2.2.2 on page 24.

To set general configuration of the NE, set TMN and OverHead parameters and to show ormodify some parameters (performance monitoring, ISA Port Configuration, MSP, EPS andcross–connection).

• Diagnosis (third column). See para.2.2.3 on page 25.

To get information about the NE (alarms, performance monitoring, remote inventory, internallink monitor).

• Supervision (fourth column). See para.2.2.4 on page 26.

To set the supervision states (i.e. Craft Terminal enabling).

• MS_SPRing (fifth column). See chapter 19 on page 377.

To manage the 2 fiber MS_SPRing protection, setting the relevant configuration.

MS–SPRing menu is available only for 1660SM

• Download (sixth column). See chapter 21 on page 439.

To manage the NE software (download, MIB management).

• Help (last column).

To activate the help.

Page 70: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

22

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Further, in the menu bar there are other menus, presented as an alternative, only when a particular objector option is selected.

– Other Menus

• Equipment (eighth column). See chapter 9 on page 115

To manage the NE as a whole, setting subracks and boards which compose it. From theEquipment view the Board view can be accessed.From the Equipment menu is also possible to start the Specific Terminal application for ISA porttraffic configuration.

• Board (eighth column). See chapter 10 on page 133.

To show the physical port available in a specific board. It is the entry point for the Port view.

• Transmission (seventh column). See chapter 14 on page 211.

It permits to show and set the Termination Point of the equipment, thus having an overview ofthe complete signal flow of the various port.The menu permits to define all the Cross Connections and manages the transmissionresources, setting the relevant configuration.Further access the Performance Monitoring and permits navigation to the Board view.It also permits to manage the MSP protection setting the relevant configuration.

• Port (seventh column). See chapter 11 on page 139.

To set and show (detailed alarm view) the transmission resources referred to the Port.It also permits to manage the MSP protection setting the relevant configuration.

• EPS (seventh column). See chapter 12 on page 177.

To manage the EPS protection, setting the relevant configuration.

EPS menu is not applicable to 1640FOX

• Synchronization (seventh column). See chapter 18 on page 355.

To show and modify synchronization parameters.

• External Points (seventh column). See chapter 6 on page 71.

To show and modify housekeeping (environmental) alarms.

Page 71: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

23

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

2.2.1 Views menu introduction

This menu permits to navigate among the views and set some parameters, by means of the followingentries:

– Backward: Go back to the previous view.

– Forward: Go to the next view.

– Equipment: Open the Equipment view. See chapter 9 on page 115.The “Equipment” menu and the”EPS” menu are then available on the menu bar.

– External Points: Open the External Point view. See chapter 6 on page 71.The “External Point” menu is then available on the menu bar.

– Transmission: Open the Transmission view. See chapter 14 on page 211.The “Transmission” menu is then available on the menu bar.

– Synchronization: Open the Synchronization view. See chapter 18 on page 355.The “Synchronization” menu is then available on the menu bar.

– Refresh: The aim of the refresh feature is to avoid a misalignment between the CT andthe managed NE.This misalignment is due to a loss of notifications coming from the NE.

– Open Object: Navigate and show the contents of the selected object: the current view change.It is equivalent to a double click on the selected object in the view area.

– Open in Window: Navigate and show the contents of the selected object.The current view doesn’t change but a new window with a new view is opened.

– Close: Close the EML–USM view, without stopping the supervision of the NE

Page 72: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

24

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

2.2.2 Configuration menu introduction

This menu permits to set general configuration of the NE and to show or modify some parameters, bymeans of the following entries:

– Alarm Severities: Manage the Alarm Severity Assignment Profile.See para. 4.3.2.1 on page 53.

– Set Alarm severities: Send the Alarm Severity Assignment Profile to the selected objectSee para. 4.3.2.2 on page 57.

– Set SdhNe Alarm severities: Send the Alarm Severity Assignment Profile referred to theequipment level.See para. 4.3.2.2 on page 57.

– NE Time: Display and set the NE local time. See para. 4.2 on page 51.

– Performance: Manage the the Performance Monitoring domain.Used to define the PM parameters, opening the following menu options:• Threshold table: See para.17.7 on page. 335.

– EPS overview : Allows to display as well as search for EPS states.See paragraph 12.5 on page 188.

EPS overview is not applicable to 1640FOX

– Set ACD level: See para.5.2 on page 70.

– Cross Connection Management: Manage the connection of the paths.See para.15.3 on page 270

– Loopback Management: Enter the loopback management. See para. 14.11 on page 242.Used to configure the loopback command for commissioning ormaintenance purposes.

– Comm/Routing: Enter the Communication and Routing management.See paragraph 8 on page 89.Used to define the parameters for NE and OS in the TMN, opening thefollowing menu options:

• Local configuration

• OS Configuration

• NTP Server Configuration

• Interfaces Configuration– LAPD Configuration– Ethernet Configuration (not applicable to 1640FOX)

• OSI Routing Configuration– RAP Configuration– MESA Configuration

• IP Configuration– IP Static Routing Configuration– OSPC Area Configuration– IP Address Configuration of point–to–point interfaces– ISA board IP address

Page 73: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

25

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

• Tunnelling Configuration– OSI Over IP (not applicable to 1640FOX)– IP Over OSI

– Overhead: Handle the operation on the Overhead bytes (not applicable to 1640FOX).See para.16 on page 301.Used to define the parameters in the following menu options:• OH Cross Connection (not applicable to 1640FOX)• OH Phone Parameter (not applicable to 1640FOX)• OH TP creation (not applicable to 1640FOX)• OH TP deleting (not applicable to 1640FOX)

– MSP overview : Allows to display as well as search for MSP states.See paragraph 13.8 on page 206.

– PM overview : It shows both both PM and Monitoring Objects. Serch operation are allowed for PM objects, Monitoring object or both.

– Port Mode : It allows a centralized mechanism for:• System wide search for Port Mode setting• Change Port Mode setting• Change of Port Mode defaultSimilar view can also be reach from Port view. Refer to paragraph 11.4 onpage 144.

– ISA port Configuration : It allows to create the TPs for the ISA connections.See paragraph 20.2 on page 428.

– Alarm Persistency Configuration: This feature has the aim to avoid transient alarm conditions.See paragraph 4.3.6 on page 66

2.2.3 Diagnosis menu introduction

This menu permits to get information about the NE, by means of the following entries:

– Alarms: Display the Alarms Surveillance information of the NE.See para. 7.1 on page 79.It opens the following menu options:• NE alarms• Object alarms• Subtree alarms• Equipment alarms• Transmission alarms• External Points alarms

– Log Browsing: Manage the events stored in the NE. See para. 7.4 on page 85It opens the following menu options:• Alarm Log• Event Log• Software Trace Log

– View Remote Inventory: Display the remote inventory data, previously stored in the Craft Terminalby means the “upload remote inventory” performed in the “Supervisory”menu. See para 7.5.2 on page 87.

Page 74: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

26

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Abnormal Condition list: Display the list of the object class (Loopback, ALS Handler, protection board) and the name of the boards that are in abnormal condition.See para 7.2 on page 81.

– Internal Link Monitor: Indicates the presence of failure on Rx or Tx side for the signalincoming/outgoing from/to the active/standby MATRIX orCOMPACT–ADM board.Refer to paragraph 7.3 on page 83.

– Data Flow Analyzer: Not operative

2.2.4 Supervision menu introduction

This menu permits to set the supervision states of the NE, by means of the following entries:

– Access State: Manage the supervision access to the NE, with CT or OS.See para.4.1 on page 49.It opens the following menu options:• OS• Requested

– Alarms: Manage the alarms supervision of the NE.It opens the following menu options:• Resynchronize. See para. 4.3.5 on page 65.• Allow / Inhibits Notifs. See para. 4.3.4 on page 64.

– Upload Remote Inventory:Store the Remote Inventory data in the Craft Terminal.See para. 7.5.1 on page 86.

– Set Manager list: See para.5.1 on page 69.

– Restart NE: Reset the NE software.See para.4.4 on page 67.

2.2.5 MS–SPRing menu introduction

MS–SPRing menu is only available for 1660SM

This menu permits to manage the 2 fiber and 4 fiber MS–SPRing protection (the last is not operative incurrent release) , setting the relevant configuration, by means of the following entries:

– Main dialog for MS–SPRing management: Contains all the command to set and manage theMS–SPRingSee para. 19.4.1 on page 381.

Page 75: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

27

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

2.2.6 Download menu introduction

This menu permits to manage the NE software, by means of the following entries:

– Init download: Manage the software download, upgrading the NE.See para.21.4 on page 443.

– Units info: Show the status of the software package installed in the NE memory banks.See para.21.5 on page 445.

– Mib management: Permits backup of NE software configuration and restore of backupped file.See para. 21.6 on page 447.

2.2.7 Equipment menu introduction

This menu permits to manage the NE as a whole, setting the boards which compose it, by means of thefollowing entries:

– Set: Add or change the board type (a list is proposed).See para. 9.2 on page 122.

– Modify: Change the board type without previously remove it. It is only possiblebetween compatible board or modules (ex. it is possible to change froman Long and Short 1.1 optical module)See para. 9.2 on page 122.

– Remove: Remove the board.See para. 9.2 on page 122.

– Set in service: Insert a lock symbol in the board. See para. 9.4.1 on page 128.

– Set out of service Delete the lock symbol in the board, enabling changes.See para. 9.4.2 on page 128.

– Reset: Not operative.

– Software description: Show information on the software of the board. See para. 9.5 on page 129.

– Remote Inventory: Show the Remote Inventory data inserted in the equipment.See para. 9.6 on page 130.It opens the following menu options:• Subrack level• Board level

– ISA Board IP Address: Used to define the ISA board IP address. See paragraph 8.14 on page 110.N.B. This option is available only at Subrack view level.

– Show supporting equipment: Navigate to the upper equipment level. See para. 9.7 on page 132.

– ISA navigate: Start the Specific Craft Terminal application for the ISA trafficmanagement configuration.For details refer to the specific ISA board Operator’s Handbook.N.B. This option is available only after having selected an ISA board

at subrack level view.

Page 76: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

28

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Connect FAN to CONGI#4:This option is available only on 1650SMC.

Enable the management of the Fan subrack alarms on CONGI insertedin slot4.

N.B. This option is available only after having selected a CONGIboard at Subrack level view.

– Connect FAN to CONGI#10:This option is available only on 1660SM.

Enable the management of the Fan subrack alarms on CONGI insertedin slot10.

N.B. This option is available only after having selected a CONGIboard at Subrack level view.

– Connect FAN to CONGI#12:This option is available only on 1660SM.

Do not use this option to manage the FAN subrack alarms!; Fansubrack alarms can be managed only by CONGI#10.

2.2.8 Board menu introduction

This menu permits to show the physical port available in a specific board (alarm synthesis and port symbol)and to access the port view, by means of the following entries:

– Port Access: Access the “Port view”. See para. 10.2.1 on page 136.

– Change Physical Interface Change the SPI or PPI object into PPI or SPI (and viceversa) on thebi–mode port( 140Mbi/s/ STM–1 switchable). See para. 10.2.2 onpage 137.

This option is not supported by 1640FOX.

– Show supporting equipment: Navigate to the upper subrack level. See para. 10.2.3 on page 138.

– ISA port Configuration: It allows to create the TPs for the ATM/PR_EA/ETH connections.See paragraph 20.2 on page 428.N.B. This menu is available only if an ATM/PR–EA/ETH board

has been equipped in the subrack.

Page 77: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

29

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

2.2.9 Port menu introduction

This menu permits to set and show the transmission resources (TP) referred to the Port, by means of theentries indicated in the following list.

The menu differs according the port type (SDH, PDH, HOA and ISA).

The “Port view” is reached by means the Equipment menu and Board view to check the detailed alarmspresented, but the available menu permits to configure the port (many setting options listed in the portmenu are common with the “Transmission” view).In these views are presented only the TP specific of the port.

It permits navigation to the Transmission view.

– TP configuration: Set parameters for the Overhead (Signal Label and Path Trace) onSynchronous TP’s. See para 14.6 on page 227.

– Port Mode Configuration: This functionality allows to manage the alarms behaviour on LOS according to the setup done at port level.Refer to paragraph 11.4 on page 144.

– TP Threshold Configuration: Set B2 excessive BER and Signal Degraded parameter.See para 14.7 on page 234.

– TP Frame Mode Configuration: Set parameters for 2Mbit/s G.703/704 or ISDN–PRAmanagement.Only for PDH ports views. See para 11.8 on page 170

– Set Retiming: Set the retiming feature applies to the outgoing 2Mbit/s. See paragraph 11.5 on page 146.It opens the following options:• Enable• Disable

– AU4 Concatenation: Only for SDH ports views. See para. 11.6 on page 148.

– Cross Connection: Manage the connection of the paths. See para.15 on page 253.It opens the following menu options:• Cross Connection Management• Create Cross Connection• Modify Cross Connection

– Monitoring Operation: Set parameters for POM/SUT/TCM/TCT TP’s.See para. 14.9 on page 236.It opens the following menu options:INot available for PDH ports.• Creation / Deletion• Configuration

– Performance: Set and show Performance Monitoring parameters and data.See chapter 17 on page 313.

IDifferent menu are available:• Configure Performance Monitoring• Display Current Data• Display History Data

Page 78: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

30

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Loopback: Enter the loopback management. See para. 14.11 on page 242.Used to configure the loopback command for commissioning ormaintenance purposes:

• Port Loopback Configuration• Loopback management

– MSP Manage the Multiplex Section Protection of the NE.See Chapter 13 on page 193.Only for SDH ports view.It opens the following menu options:

• MSP Create• MSP Management• MSP Commands• MSP Delete

– Physical Media: Manage the physical setting of the TP of the ports. Not applicable to HOAport. See para.11.7 on page 151.It opens a menu which differs according the port type:

– SDH port:• ALS Management• Show Optical Configuration• TX Quality Configuration• Single Fiber Configuration• LAPD Configuration• Ms Configuration

– PDH port:• Line Length Configuration• HDSL Configuration (not operative)• NT G703/704 Configuration (not operative)• NT X21 Configuration (not operative)

– ETHERNET port:• Remote Laser Management (not operative)• ALS Management (not operative)• Ethernet Port Configuration• Ethernet Mapping Protocol• ISA Port Configuration• Control Path Activation• LCAS Configuration

– Show supporting board: Navigate to the upper board level.See para.11.9 on page 173.

– Navigate to Transmission view: permit to show a complete overview about the signal flow, openingall TP’sSee para.11.10 on page 174

– Navigate to Monitoring view: permit to show for a selected TP the related POM/SUT/TCM and TCTobject if present.

– Navigate to HOA port view: permit to show the HOA port associated to a selected TP (forexample, the HOA port associated to an AU4 ia a VC4).It is available only on SDH ports.

Page 79: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

31

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

2.2.10 EPS menu introduction

This menu is not supported by 1640FOX.

This menu permits to manage the EPS protection, setting the relevant configuration, by means of thefollowing entries :

– Management: Set EPS protections. See para.12.2 on page 178.

– Configure: Set revertive / not revertive and WTR parameters.See para. 12.3 on page 185.

– Switch: Manage the EPS operator commands (Force, Manual, Lockout)See para.12.4 on page 187.

2.2.11 Transmission menu introduction

This menu permits to show and set the Termination Point of the equipment, thus having an overview ofthe complete signal flow of the various port.

The menu permits to define all the Cross Connections and manages the transmission resources, settingthe relevant configuration.

Further access the Performance Monitoring and manage Multiplex Section Protections and Loopbacksfunctions.

It permits navigation to the Port view.

The menu lists the following entries:

– Add TP: Search and add TP to the transmission view, than presented in the screen.See para.14.5 on page 217.

– Expand: Display the TP’s related to a selected TP. See para.14.13.1 on page 249.It opens the following menu options:• Next level of lower TP• All lower TP• Next level of upper TP• All upper TP

– Hide: Remove the TP from the screen of the Transmission view.See para.14.13.2 on page 250.It opens the following menu options:• Lower TP• Upper TP• Selected TP

– Port Mode Configuration: This functionality allows to manage the alarms behaviour on LOS according to the setup done at port level.Refer to paragraph 11.4 on page 144.

– TP configuration: Set parameters for the Signal Label and Path trace.See para.14.6 on page 227.

Page 80: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

32

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– TP Frame Mode Configuration: Set parameters for 2Mbit/s G.703/704 or ISDN–PRAmanagement.Only for PDH ports views. See para 11.8 on page 170

– TP Threshold Configuration: Set B2 Ex BER and Signal Degrade threshold.See para. 14.7 on page 234.

– Terminate TP: Terminate the AU4–CTP paths. See para.14.8 on page 235.

– Disterminate TP: Disterminate the AU4–CTP paths. See para.14.8 on page 235

– AU4 Concatenation Only for SDH ports views. See para. 11.6 on page 148.

– Cross Connection: Manage the connection of the paths. See para.15 on page 253.It opens the following menu options:• Cross Connection Management• Create Cross Connection• Modify Cross Connection• Port Switch Over• Show Cross Connected TP’s

– Monitoring Operation: Set parameters for POM/ SUT/TCT/TCM TP’s.See para.14.9 on page 236It opens the following menu options:• Creation / deletion• Configuration

– Performance: Set and show Performance Monitoring parameters and data.See chapter 17 on page 313.

Different menu are available:• Configure Performance Monitoring• Display Current Data• Display History Data

– Structure TP’s: Define the structure of a selected TP (TU2, TU3, TU12, VC3/VC4, VC12)See para.14.10 on page 241.

– Loopback : Enter the loopback management. See para. 14.11 on page 242.Used to configure the loopback command for commissioning ormaintenance purposes:It opens the following menu options:• Port Loopback Configuration• Loopback management

Page 81: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

33

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Physical Media: Manage the TP physical setting. See para.14.12 on page 247.It opens the following menu options:• ALS Management• Show Optical Configuration• TX Quality Configuration• Single Fiber Configuration• Extra traffic• Regeneration Section management• Line Length Configuration• Set Domain• HDSL Configuration (not operative)• NT Configuration (not operative)• X21 Configuration (not operative)

– MSP Manage the Multiplex Section Protection of the NE.It opens the following menu options:• MSP Create• MSP Management• MSP Commands• MSP Delete• NE MSP synthesis

– Show supported board: Navigate to the board supporting the selected TPSee para.14.13.3 on page 251.

– Navigate to Port view: Navigate to the port supporting the selected TPSee para.14.13.4 on page 252.

2.2.12 Synchronization menu introduction

This menu permits to set and show the Synchronization parameters and status, setting the relevantconfiguration, by means of the following entries :

– Timing Source Configuration: Set timing source priority and quality for the selected input reference.See para.18.2.3 on page 361.

– Protection Command: Manage commands (force, manual, lockout) for the selected timingreference. See para.18.2.4 on page 364.

– T0 Configuration: Enable/disable SSM and WTR on the T0 synchronization source.See para.18.2.5 on page 365.

– T4 Configuration: Enable/disable SSM, WTR and Squelch Criteria on the T4synchronization source. See para.18.2.5 on page 365.

– SSU Configuration: Set NE single or with SSU. See para.18.2.6 on page 368.

– Transmitted SSM Quality Configuration: Set SSM quality transmitted on the selected T1 SDHtiming reference. See para.18.2.11 on page 375.

– Frame Mode Configuration: Set parameters for 2Mbit/s G.703/704 or ISDN–PRAmanagement.Only for PDH ports views. See para 11.8 on page 170

– Remove Timing Reference See para.18.2.7 on page 369.

Page 82: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

34

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Change T4<–>T5:This option is not supported by 1640FOX.

Change the synchronization physical interface from 2MHz (T4)to2Mbit/s (T5) without traffic” and vice–versa (see para18.2.8 onpage 370.

– Change 2MHz–>2MbitThis option is not supported by 1640FOX.

Change the source of a protection unit from 2Mhz (T3) to 2Mbit(T6)and viceversa (see para. 18.2.9 on page 372).

– Set T0 Equal T4 See para.18.2.10 on page 374.

– Remove T0 Equal T4 See para.18.2.10 on page 374.

– Show Timing Source: Show the “port view” related to the selected timing reference.See para.18.2.12 on page 376.

2.2.13 External Points menu introduction

This menu permits to display and set the input/output environmental alarm (housekeeping alarm), bymeans of the following entries:

– Configuration: Set the input/output environmental alarm.See para. 6.2 on page 75.

– Display: Show the list of the input/output environmental alarm.See para. 6.1 on page 72.It opens the following menu options:

• Show external Input Points• Show external Output Points• Show all external Points

Page 83: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

35

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ËËËËËËËËËË

Views

Backward

Equipment

External Points

Transmission

Synchronization

Open Object

Open in Window

Close

D

C

B

A

Forward

Refresh

Refer to Figure 7.

Refer to Figure 10.

Refer to Figure 9.

Refer to Figure 10.

F Refer to Figure 10.

Figure 4. Menu options flow chart – 1

Page 84: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

36

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ËËËËËËËËËËËËConfiguration

Comm/Routing

Overhead

Local Configuration

OS Configuration

NTP Server

Interfaces

OSI Routing

IP Configuration

OH Cross

OH TP Creation

OH TP Deleting

Configuration

Configuration

Connection

Alarm Severities

Set Alarm Severities

NE Time

Performance

Set ACD level

Cross ConnectionManagement

ÇÇÇÇÇÇÇÇÇÇÇÇ

Threshold table

ÇÇÇÇÇÇÇÇÇÇÇÇ

Oh PhoneParameters

LoopbackManagement

SeveritiesSet SdhNe Alarm

MSP overview

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

LAPD Configuration

Ethernet

RAP Configuration

MESA Configuration

ConfigurationConfiguration

ÇÇÇÇÇÇÇÇÇÇÇÇ

TunnelingConfiguration

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

IP Static Routing

OSPF Area

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ÁÁÁÁÁÁÁÁÁÁÁÁ

IP Address Config.

IP over OSI

EPS overview

ISA port

Configuration

Configuration

of Point–toPoint interfaces

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ

ISA board IP address

ÁÁÁÁÁÁÁÁÁÁÁÁ

OSI over IP

Configuration

PM Overview

Alarm PersistencyConfiguration

Port Mode

Figure 5. Menu options flow chart – 2

Page 85: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

37

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ËËËËËËËËËËËËDiagnosis

Alarms

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

NE alarms

Object alarms

Equipment alarms

Transmission alarms

External Points

Log Browsing

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

Alarm Log

Event Log

View

Subtree alarms

alarms

Abnormal Condition List

ÇÇÇÇÇÇÇÇÇÇÇÇSoftware Trace Log

Internal LinkMonitor

ËËËËËËËËËËSupervision

Access State

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

OS

Requested

Alarms

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

Resynchronize

Allow Notifs

Upload Remote

Set Manager list

Inventory

Restart NE

ÇÇÇÇÇÇÇÇÇÇ

Inhibit Notifs

Data flow analyzer

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

Remote Inventory

Figure 6. Menu options flow chart – 3

Page 86: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

38

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ËËËËËËËËËËMS_SPRing

Main Dialog for MS_SPRingmanagement

ËËËËËËËËËË

Download

Init download

Units info

Mib Management

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ËËËËËËËËËËEquipment

Set

Modify

Remove

Set in service

Set out of service

Software

Remote Inventory

Show supporting

Reset

description

equipment

Subrack level

Board level

A

G

ISA Navigate

ISA Board IP Address

Connect FAN to CONGI#10

Connect FAN to CONGI#12

NB.2

NB.2

Connect FAN to CONGI#04 NB.1

Refer to Figure 8.

Refer to Figure 4.

NB.1– avaialble only if CONGI board has been selected in the 1650SMC Subrack level view

Notes:

NB.2– available only if CONGI board has been selectedin the 1660SM Subrack levle view

NB.3

NB.3– available only if an ISA ATM / ISA PREA / ISA ES board has been selected.

Figure 7. Menu options flow chart – 4

Page 87: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

39

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

Physical Media:

TP configuration

CrossConnection

with SDH port

with PDH port

AU4Concatenation

Cross ConnectionManagement

Create Cross Connection

Modify CrossConnection

Set Retiming

Enable

Disable

Performance

Display CurrentData

Navigate toTransmission view

Show supportingboard

ËËËËËËËËËËËËPort

F

Notes:

TP Thresholdsconfiguration

nb2

nb1: only for PDH port nb2: only for SDH port

Loopback

MSP

C

Creation / deletion

Configuration

TP Frame modeconfiguration nb1

nb1

MonitoringOperations

Navigate to

with ETHERNET port

Remote laserManagement

nb2

Monitoring view

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ConfigurePerformance Monitoring

Display HistoryData

Port LoopbackConfiguration

Loopback management

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

MSP Management

MSP Commands

MSP Delete

MSP Create

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇ

ALSManagement

Ethernet portConfiguration

ISA port Configuration

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

Show OpticalConfiguration

ALSManagement

Tx Quality Configuration

LAPD config.

Single FiberConfiguration

Ms Configuration

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

Configuration

HDSLConfiguration

NT G703/G704Configuration

NT X21 Configuration

Line Lenght

ËËËËËËËËËËËËËËË

Port Access

Show supporting

Board

equipment

G

F

Change PhysicalInterface

ConfigurationISA port

Refer to Figure 7.

Refer to Figure 9.

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

Ethernet mappingProtocol

ÇÇÇÇÇÇÇÇÇÇ

Control PathActivation

Navigate toHOA port

Port ModeConfiguration

ÇÇÇÇÇÇÇÇÇÇ

LCAS Configuration

Figure 8. Menu options flow chart – 5

Page 88: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

40

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇ

ÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

Next Level ofLower TPs

Next Level of

All Lower TPs

Upper TPs

ËËËËËËËËËËËË

Transmission

Add TP

Expand

Hide

All Upper TPs

Lower TPsUpper TPs

TP configuration

AU4 Concatenation

Cross Connection

Cross ConnectionManagement

Create Cross Connections

Modify CrossConnections

Show Cross Connected TPs

Port Switch Over

Monitoring

Creation / DeletionConfiguration

Performance

Structure TPs

Regeneration Section management

Show SupportedBoards

Navigate toPort View

Configure

Monitoring

Display CurrentData

Physical Media:

C

F

Loopback

Set Domain

MSP

TP ThresholdConfiguration

Terminate TP

Disterninate TP

TP Frame modeconfiguration

Operations

Refer to Figure 8.

Refer to Figure 4.

ÇÇÇÇÇÇÇÇÇÇÇÇ

Display HistoryData

ÇÇÇÇÇÇÇÇÇÇÇÇ

Selected TPs

ÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

TU2TU3TU12AU3AU4

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

Port LoopbackConfiguration

Loopbackmanagement

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

MSP CreateMSP ManagementMSP CommandsMSP DeleteNE MSP synthesis

ÇÇÇÇÇÇÇÇÇÇÇÇALS Management

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

TX QualityConfiguration

Show OpticalConfiguration

Single FiberConfiguration

Extra traffic

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

Line LenghtConfiguration

HDSLConfiguration

NT Configuration

X21 Configuration

Performance

Port ModeConfiguration

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

VC3/VC4VC12

Figure 9. Menu options flow chart – 6

Page 89: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

41

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ËËËËËËËËËË

Eps

Management

Configure

Switch

ËËËËËËËËËËËË

Synchronization

T0 Configuration

T4 Configuration

SSU Configuration

Set T0 Equal T4

Timing SourceConfiguration

ProtectionCommand

Remove TimingReference

TransmittedSSM QualityConfiguration

Show TimingSource

ËËËËËËËËËËËË

External Points

Configuration

Display

RemoveT0 Equal T4

E D B

Change T4 <–> T5

Frame Mode Configuration

Change 2MHz –> 2Mbit

Refer to Figure 4. Refer to Figure 4. Refer to Figure 4.

ÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇÇ

ÇÇÇÇÇÇÇÇÇÇÇÇ

Show ExternalInput Points

Show ExternalOutput Points

Show AllExternal Points

Figure 10. Menu options flow chart – 7

Page 90: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

42

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

2.3 Advices on Navigation principles

Navigation rules are the same for all the NE using the same Craft Terminal Info Model.

This general rules are described in the “Basic Craft Terminal Operator Handbook”.

In this paragraphs are instead inserted menu options typical for every NEs involved in Navigation andexample of Navigation.

To reach a particular view of the NE there are several ways (navigation is also possible mixing the differentways):

• double click on the selected object

• select the object and use the Open object or Open in Window option of the View pull downmenu

• use the Menu option tree structure. The View pull down menu permits to show the followingmenus:

– Equipment– Transmission– Synchronization– External Points

The menu structure permits to open the same window following several menu paths.

EXAMPLE: to obtain the “Create Cross Connection” window:

– First navigation path:Open View – Transmission pull down menuOpen Transmission – Cross Connection – Cross Connection Management pull downmenuSelect Create option in the presented window

– Second navigation path:Open View – Equipment pull down menuDouble click on Board bodySelect the Board to access the Board viewOpen Board – Port Access pull down menuOpen Port – Cross Connection – Create Cross Connection pull down menu

– Third navigation path:Open Configuration – Cross Connection Management pull down menuSelect Create option in the presented window

The menu structure also permits to pass from a view menu to another (i.e. from “port view” to”board view”or to “transmission view”) thus facilitating the operators activity.

Depending on which object the mouse arrow is located, a related pop–up menu can be activated by meansof the right button of the mouse; this menu is correspondent to the possible actions that can be done onthe specific object of the view.

Page 91: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

43

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Views Navigation

The first level of the “Equipment view” representation will be displayed directly into the current window,immediately after the NE login. (See Figure 1. on page 18, Figure 2. on page 19 and Figure 3. on page20).The Equipment view enables a fast navigation through all levels of the equipment hierarchy.Navigation is done from higher to lower levels.

The NEs hierarchy is different organized according to the equipment type, as follow:

– 1660SM & 1650SMC:

Subrack > board > port > TP

The navigation through different levels of the NE hierarchy is performed by double clicking on theobjects (see also para 9.1, pg. 115):

• the first level shows the subrack level of the Equipment view (see Figure 2. on page 19 andFigure 3. on page 20);

• by double clicking on a board body , the board level of the Equipment view can be reached.• further, by double clicking on a port body contained in the board, the port level of the Equipment

view can be reached. The port view displays the inner TPs.• it is possible to go back to the upper level of representation by pressing the <ESC> key on the

keyboard;It is also possible to:– go back to the previous view, by selecting the Backward option from the views menu– go to the next view, by selecting the Forward option from the view menu.

N.B. Selecting in the first level of the Equipment view ( subrack level, see Figure 2. on page19 and Figure 3. on page 20 ) the Show supporting equipment option from theEquipment menu, the Rack level view is presented.

In the Rack Level view two subracks are presented:

– at the top the Equipment Subrack (example “SR60M” for 1660SM or “SR50C” for1650SMC)

– at the bottom the Fans Subrack, named SRFAN.The Fans Subrack presence is managed with the Set option as for the boards of theEquipment Subrack (refer to paragraph 9.2 on page 122 for details)

Further, selecting in the Rack level view the Show supporting equipment option from theEquipment menu, the Equipment level view is presented.

Page 92: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

44

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– 1640FOX:

Rack > Subrack > board > port > TP.

The navigation through different levels of the NE hierarchy is performed by double clicking on theobjects (see also para 9.1, on page 115):

• the first level shows the Rack level of the Equipment view (see Figure 1. on page 18); twosubracks are presented:

– at the top the Equipment Subrack “SR40M”– at the bottom the AC/DC Rectifier Subrack, named “SR40R”

by double clicking on a Subrack body, the relevant subrack level of the Equipment view can bereached.

• by double clicking on a board body, the board level of the Equipment view can be reached.• further, by double clicking on a port body contained in the board, the port level of the Equipment

view can be reached. The port view displays the inner TPs.• it is possible to go back to the previous level of representation by pressing the <ESC> key on

the keyboard; or:– go back to the previous view, by selecting the Backward option from the Views menu– go to the next view, by selecting the Forward option from the Views menu.

N.B. Selecting, in the first level of the Rack view (rack level, see Figure 1. on page 18 ), the Showsupporting equipment option from the Equipment menu, the Equipment level overview ispresented.

Page 93: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

45

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

3 NE MANAGEMENT SUPERVISION

This chapter is dedicated to the NE states and NE access.

3.1 NE management states

The elementary building blocks of any telecommunication network are the Network Elements (NEs).

Operating with the Craft Terminal the NE can present different management states according to thecondition of the connection (supervision, local access, connection state, etc). Also general Alarm statusare presented.Management states are present at Network Element Synthesis view level and at USM–EML view level.All the information referred to the management states are inserted in the Basic Craft Terminal Operator’sHandbook.Any disruption in the communication link between the CT and the NE results in an update of themanagement states when the CT has detected the communication failure.

Page 94: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

46

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

3.2 NE supervision and login

The Network Element Synthesis views enable you to get access to the current NE EML–USM viewdescribed in this handbook.

The Network Element Synthesis views enable you to work on “local” or “remote” NE, selecting it andactivating “Supervision” and “Show Equipment”, as described in the Basic Craft Terminal Operator’sHandbook.

The EML–USM Main view is presented as for the following figures.

LCA

Figure 11. 1640FOX: EML–USM Main view.

Page 95: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

47

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LCA

Figure 12. 1650SMC: EML–USM Main view.

LCA

Figure 13. 1660SM: EML–USM Main view.

Page 96: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

48

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 97: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

49

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4 NE MANAGEMENT GENERAL CONFIGURATION

In this chapter general configuration referred to the equipment management are described (Craft Terminalaccess, NE Time, Alarms configuration, etc).

4.1 Access state (allow or inhibit NE Craft access)

The NE can be managed by the OS or by the Craft Terminal. To control the competition of the OS and theCT, a Local Access Control (LAC) is available.

If the LAC is “Granted!” that means the CT is allowed to manage the NE, the icon “LCA” has a greenrectangular shape.

If the LAC is ”Denied” that means the OS manages the NE and the CT is not allowed to modify NEconfiguration (it can only “read”), the icon “LCA” has a cyan circular shape.

If the LAC is ”Requested!” that means the CT has requested permission to the OS and is waiting for areplay, the icon “LCA” has a blue circular shape.

However the OS does continue to provide a certain number of services. These services includes:

– Reception and processing of alarms,– Performance processing on TPs,– Switching back to the OS access state.

The access state of an NE can be modified from two types of views:

Page 98: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

50

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.1.1 Switching from the OS to the Craft Terminal access state

Select the Supervision pull down menu. Then select the Requested option from the Access Statecascading menu as shown in the following figure.

Figure 14. NE management: setting the access state.

From the confirmation dialogue box that opens you can confirm or cancel the ”Craft access” operationusing the Yes or No push buttons. the request is up to the OS which accept or refuse it.If the OS doesn’t answer in a predefined time it is assumed that the NE is in the Craft access stateand can be managed from a Craft Terminal.

4.1.2 Switching from the Craft Terminal access state back to the OS access state

Select the Supervision pull down menu. Then select the OS... option from the Access Statecascading menu in Figure 14. From the confirmation dialogue box that opens you can confirm or cancel the ”OS access” operation.The NE is now managed by the OS.

N.B. The key symbol icon on the management states of the NE view, indicates whether the NE ismanaged by a Craft Terminal or by the OS.

N.B. Local Craft Terminal access is denied on recovery phase after a loss of communication of theNE. When communication is lost with the NE, the OS automatically recovers the communicationand put the state that was set before the loss of communication (therefore the Craft Terminalaccess can be denied or granted).

Page 99: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

51

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.2 NE Time management

The NE local time of a selected NE can be visualized and/or re–aligned on the OS time basis.In this view the OS indication identifies the Craft Terminal.The status of the Network Time Protocol can be checked

Select the NE Time... option from the Configuration pull down menu.

Figure 15. Consulting and/or setting the local NE time.

The following dialogue box is opened from which you can get and/or set the local NE time and check theNTP Status.

Figure 16. NE Time dialogue box.

Page 100: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

52

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The following fields are available:

– NTP Status section (read only) with the following parameters:

• NTP protocolIt can be enabled (in the NTP Server Configuration option at para 8.5 on page 98) or disabledor empty (greyed).

• NTP Main and NTP SpareIt displays the status of the Main and Spare NTP: reachable or unreachable.

– Time section with the following data:

• NE Time and OS TimeIt displays (read only) the time of the Network Element and of the OS (Craft Terminal).

• Set NE Time With OS TimeIt permits to align the NE time with the time of the Craft Terminal.

Two different operative conditions can be defined:

– NTP protocol enabledIn this case, NTP Main and NTP Spare will be reachable or unreachable. When both are reachablethe NE uses the Main.The Set NE Time With OS Time message is not operative and the user cannot set manually the NETime.

– NTP protocol disabledIn this case, the NTP Main and NTP Spare are empty (greyed); the Set NE Time With OS Timemessage is operative and the user can set manually the NE Time (i.e. change the NE time with theTime of the Craft Terminal).

If you do not want to set the NE local time, click on the Close push button to close the dialogue box.

To re–align the NE time on the OS time basis click in the Set NE Time With OS Time radio button and eitherclick on the Apply push button to validate or on the Close push button to cancel and close the dialoguebox. The OS time comes from the PC date configuration which corresponds to the legal GMT time.

N.B. When the NTP is not present, the OS system re–aligns the time of all supervised NEsperiodically and automatically with a configured periodicity. This periodicity is common for allthe NEs.If you set the NE time, you will force the change, with an immediate effect on the NE. Howeverit will not have any effect on the periodic and automatic mechanism.

Page 101: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

53

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.3 Alarm Configuration

The operations described in this chapter, mainly related to alarm setting, are:

– Alarm Severity Assignment Profile management,– Allow/Inhibit alarm notification,– Alarm re–synchronization.

4.3.1 Procedure to modify an ASAP

a ) Select the TP (or the board/port/etc...) whose ASAP is to be changedb ) from the menu click on “Configuration” –> “Alarms Severities...”c ) (see Figure 18. on page 54 ) select one of the “user” profiles (#10001 or #10002) and click on

“Modify”d ) (see Figure 19. on page 56) click on the “Probable Cause Families” associated to the alarme ) select the relevant alarm in the list of “Probable Cause Name”f ) in the “Service affecting/non–affecting” fields select the needed severity (critical/major/minor...)g ) click on “OK”h ) (see Figure 18. ) click on “Close”i ) select the relevant TP and then “Configuration” –> “Set Alarms Severities...”j ) in the box that appears select the just modified ASAP (eventually check it by means of “Detail”)k ) click on “OK”

For further details see paragraphs 4.3.2, 4.3.2.1, 4.3.2.2.

4.3.2 Alarm Severity Assignment Profile Management (ASAP)

Managed entities yield alarms when they malfunction. This section deals with the configuration of ASAPs.An ASAP is a list of Alarm probable causes to which Severities Profiles are assigned, predefined orsettable by the operator.

Three important notions are:

– The Probable Cause of the alarm,– The Severity of the alarm.– The Alarm Type (communication alarm, equipment alarm).

4.3.2.1 Alarm Severities

This option permits to configure and display the ASAP.

Select the Alarm Severities... option from the Configuration pull down menu.

Page 102: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

54

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 17. Configuring Alarm Severity Assignment Profile.

The ASAP Management dialogue box is displayed.

Figure 18. ASAPs Management dialogue box.

Page 103: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

55

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The default presented profiles are:

• Profile ”All Alarms”. With this profile all the alarms are enabled (only Sfwr Download Failureis not alarmed).This ASAP enables the emission of all alarms.

• Profile “No Remote Alarms”shows the alarm criterion configuration defined for ”path alarms”(only AIS and RDI and Sfwr Download Failure are not alarmed)This ASAP enables the emission of all:

– Communication Alarms (i.e. the AIS & RDI alarms are not alarmed)– Equipment alarms– Environmental– Error Processing (i.e. Sfwr Download Failure is not alarmed)

• Profile ”Primary alarms”. With this profile the AIS, Battery Degraded, Sfwr Download Failure,SSF and RDI alarms are not alarmed.This ASAP enables the emission of all:

– Communication Alarms (i.e. the AIS, SSF & RDI alarms are not alarmed)– Equipment alarms– Environmental– Error Processing (i.e. Sfwr Download Failure is not alarmed)

• Profile “No Alarms” : (i.e. all alarms disabled).This ASAP inhibits the emission of any potential alarm.

• Profile “10001” can be set by the user.Each single alarm can be classified with a criterion selected by the operator.A default standard configuration is set (Battery Degraded, Battery Failure, CommunicationSubsystem Failure, Path Trace Mismatch are not alarmed).NOTE: if this profile is not already present in the list, it is necessary to create it, by using thedialog of Figure 18. , selecting one existing profile and then clicking on the Clone button.

• Another Profile #10002 can be created by the user, as explained for the #10001; the profileidentifier is incremented automatically.

For ASAP “10001” and “10002” is then possible to choose Detail, Modify, Clone or Delete buttons.For ASAP “No Alarms” , ”Primary alarms”, “No Remote Alarms” and ”All Alarms” it is only possible tochoose Detail, or Clone buttons.Clone selection can be used to create new ASAP.

By selecting an ASAP and clicking on Detail, Modify, or Clone button, the following ASAP edition dialoguebox is displayed.

Page 104: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

56

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 19. ASAP Edition dialogue box.

The alarm severity assignment profile dialogue box displays a list of probable causes and a list of alarmseverity.The Probable Cause Families check buttons allows to filter the probable causes that will appear in theProbable Cause Name list. NOTE: it is necessary to choose one or more of these filters to have the list.To find a particular probable cause, enter its name in the Search entry box at the bottom.

ASAPs are already defined in the system with default values for the assigned severities.You can modify the severity associated with each probable cause. To do this, select the probable causewhose severity level you wish to modify.Then click on the option button: Service Affecting (not protected probable cause), and then Non ServiceAffecting (protected probable cause) and then Service Independent (don’t used, it is not operative). Foreach the severity can be chosen from ”Critical”, ”Major”, ”Minor”, ”Warning”, ”Non–alarmed” or “Not used”.A ”Non–alarmed” probable cause corresponds to no alarm emitted for this probable cause.When selecting Details the assigned severity are only shown and it isn’t possible to modify.When you have finished configuring ASAP, press the OK button to confirm the settings and close thedialogue box or the Cancel push button to cancel the new settings and close the dialogue box.

When Clone an ASAP the created one is identified with next number (10002, ....).The max number of ASAP is six.

N.B. The number of severities and the number of probable causes is fixed. The ASAP function onlyenables the modification of the severities assigned to the probable causes, it does not allow theaddition, removal or modification of these severities and causes.

N.B. To take into account a profile modification, it is mandatory to perform a re–synchronization ofthe alarms (see para. 4.3.5 on page. 65). During this re–synchronization, the severity of eachalarm is updated. Otherwise, the severities are updated only when the modified or new alarmsare emitted by the NE.

Page 105: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

57

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.3.2.2 Set Alarm Severities

This option permits to send (i.e. to provision) the chosen ASAP to the previously selected object (rack,subrack, board, port, TP).If the severity profile is to be changed, it must be done by means of the Modify option, as described inthe previous paragraph (see procedure in paragraph 4.3.1, page 53).

It permits also to check the currently operative ASAP used by the object.

Select the Set Alarm Severities... option from the Configuration pull down menu as for Figure 17. onpage 54. Note: the Set Alarm Severities option is accessible only if an object has been selected.

The Set ASAP dialogue box is displayed (Figure 20. ). The List of ASAPs on the left side lists all availableASAPs (Alarm Severity Assignment Profiles). The ASAP currently operative on the object is highlighted.To choose an ASAP select a new one of the presented list.Clicking on Detail button, or double–clicking on an ASAP, a dialogue box is displayed, as that inFigure 19. , page 56, which displays detailed information about this ASAP.

Figure 20. Set ASAP dialogue box (example)

Page 106: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

58

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Within the “Apply to” section on the right side, the user specifies the objects (TP or equipment) the ASAPselected in the List of ASAPs (new ASAP) should be applied to:

Choose Scope

– Selected object onlyThe new ASAP is only applied to the object currently selected in the view.This is the default if an object is selected in the view.

– Network elementThe new ASAP is applied to all objects of the NE matching the criteria specified in “Choose Classes”and “Choose current ASAP”.Since this application process takes some time, its progress is shown in the Section “ExecutionMonitoring”.This is the default if no object is selected in the view.

– Selected object and subordinatesThe new ASAP is applied to the selected object and those of its subordinates matching the criteriaspecified in “Choose Classes” and “Choose current ASAP”.Since this application process takes some time, its progress is shown in the Section “ExecutionMonitoring”.

N.B. Due to system architecture, AU–4 CTPs are no subordinates of MSTTPs. Therefore, if theAU–4 CTP should be included as subordinate, select the related OSTTP (OpS) or ESTTP(ElS) as main object.

Choose Class(es)

Enabled if one of the scopes “Network element” or “Selected object and subordinates” is selected.

– All classes

– Specific class(es)Select one or more object classes the new ASAP shall be applied to.

Choose current ASAP

The new ASAP is only applied to objects which are currently assigned to this ASAP.

Execution Monitoring

Continuously shows the number of modified objects during the ASAP application process if one of thescopes “Network element“ or “Selected object and subordinates“ is chosen.

Press Ok to confirm the ASAP assignment and close the dialog. Press Cancel to close the dialog anddiscard any changes.The TP list.... button let the operator to search for resources assigned to a specific ASAP and to changeASAP on multiple object istances; for detail concerning the clipboard refer to paragraph 4.3.2.3 on page59.

Page 107: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

59

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.3.2.3 Clipboard Dialog

Note: Clipboard dialog is not called directly from a view menu entry . It is started as sub–dialog from another dialog using the TP List button.In principle, every dialog supporting clipboard can be the starting point to obtain a list ofresources assigned to an ASAP .

Use the Clipboard dialog to perform the same action, e.g. PM configuration, on a number of objects (TPsor equipment) in one step.

Clipboard layout is depicted in Figure 21. on page 59.

Figure 21. Clipboard dialog layout

The list box on the left side of the dialog displays all the Objects (TPs or equipment) the user has selected(refer to Figure 21. ) for the current action.

The buttons on the right side of the dialog are used to create a list of objects:

– Add Tp Opens the TP Search dialog in which the user selects the TPs to be configured. The selectedTPs are added to the clipboard list.

– Add EQP Opens the Equipment Filter dialog in which the user selects the equipment to beconfigured. The selected equipment is added to the clipboard list.

Page 108: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

60

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Delete Deletes the selected objects from the clipboard list.

– Delete All Deletes all objects from the clipboard list.

– Load/Save Opens the User Preference dialog where a preference set can be loaded or saved. If apreference set has been loaded, the name of this set is displayed on the lower left side of the dialog.

– Print The Print dialog opens and the user selects the print destination and print format.

– Start Starts the action process on the listed objects. The semantics of the action is defined in thecalling dialog. After starting, an information window opens to cancel the action during its progress.Click on Ok to cancel the process.

– Continue Continues an action performed on the clipboard which was previously cancelled.

– Close Closes the Clipboard dialog

Clipboard dialog starts an improved version of TP search dialog (Figure 22. on page 60 ) (with supportfor ASAP management and Performance Monitoring/Monitoring operations as well) using the AddTP...button.

Figure 22. Tp search dialog with support for ASAP filtering

Page 109: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

61

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Add Eqp... button in clipboard starts the EqpSearch dialog with support for ASAP filtering Figure 23.

Figure 23. Equipment search dialog with ASAP filtering support

The use case to search for ASAP assigned resources (both TPs and Eqp resources) could be summarizedin the following steps:

– Open the ASAP Enhanced dialog

– Push the TP list ... button to build up the clipboard dialog

– From the clipboard dialog ask for TP by Add TP... button

– In TP search use the ASAP filter to search for TPs using the selected ASAP.

– Move the result of search operations into the clipboard.

Page 110: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

62

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– From the clipboard dialog ask for Equipment objects using the Add Eqp... button

– In Eqp Search dialog use the ASAP filter to search for equipment objects using the selected ASAP.

– The content of clipboard is the list of resources assigned to a specific ASAP. It is possible to changethe ASAP for this list of objects (since the first operation was the invoke of ASAP Enhanced dialog),to select the object instance to move toward a view (according to the object instance type), toload/save this object instance list and to Print it.

In Figure 24. on page 62 a representation of this use case is presented.

LCA

Figure 24. Search for resources assigned to ASAP

Page 111: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

63

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.3.3 Set SdhNE Alarms Severities

Selecting the Set SdhNE Alarms Severities option from the Configuration pull down menu only thealarms at Equipment level are managed as reported in the table below.

Table 1. SDH NE alarms

1640FOX 1650SMC 1660SM

FF (not used) FF FF

ABF (not used) ABF ABF

SDH NEs managed alarms CFF – –

BKF (not used) – BKF

SHD SHD SHD

Note: for details information on SDH NE alarms refer to Section 4 “NE MAINTENANCE”.

Figure 25. Set SdhNE Alarms Severities

If an object was selected in a view before opening this dialog, its ASAP is highlighted in the list. Using theDetail button or double–clicking on a list item opens the ASAP Edition dialog which displays detailedinformation on this ASAP.

Press Ok to confirm the ASAP assignment and close the dialog. Press Close to close the dialog anddiscard any changes.

Page 112: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

64

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.3.4 Allow/Inhibit Alarms Notifications

The system provides the possibility to allow/inhibit the spontaneous incoming alarm notifications.

l ) To inhibit alarm notification,Select the Supervision pull down menu. You can then select the Inhibit Notifs option from the Alarmspull down menu as shown in the following figure.

Figure 26. Inhibit alarm notification

From the confirmation dialogue box that opens you can confirm or cancel the operation using the Okor Cancel push buttons respectively.To inform the operator that alarms have been inhibited, the labels of the alarm panel are greyed out.

N.B. Inhibiting the alarms notification means that they are not forwarded to the CT but alarmsare still generated by the NE.

m ) To allow alarm notificationSelect the Supervision pull down menu. You can then select the Allow Notifs option from the Alarmspull down menu as shown in the following figure.

Figure 27. Allow alarm notifications

From the confirmation dialogue box that opens you can confirm or cancel the operation using the Okor Cancel push buttons respectively.

Page 113: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

65

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.3.5 Alarms re–synchronization

The system provides the possibility to recover alarms present on the NE and to update the current problemlist of the NE. After this operation CT and NE current alarms are consistent.

To re–synchronize the alarms, select the Supervision pull down menu. You can then select theResynchronize option from the Alarms pull down menu as shown in the following figure.

Figure 28. Alarm re–synchronization

From the confirmation dialogue box that opens you can confirm or cancel the operation using the Ok orCancel push buttons respectively.

N.B. This functionality has to be used only if there is any perturbation. Never use this operation duringa correct behavior.

Page 114: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

66

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.3.6 Alarms Persistency Configuration

This feature has the aim to avoid transient alarm conditions on 2Mbit/s signals. To get this goal the networkelement perform a persistency check on the fault causes, before declaring a failure. Once the failure isdeclared, it shall be cleared if the fault cause is absent continiously for a persistency time.

Select the Alarm Persistency Configuration option from the Configuration pull down menu.

The Alarm Persistency Configuration dialog box is displayed:

Figure 29. Alarm Persistency Time configuration window

It is possible to choose between two options:

– Default value : raising time O.25 sec; clearing time 5 sec– UMTS Network: raising time 30 sec; clearing time 30 sec

Customize is not operative in current release

Click on Ok button to confirm the selected value.

Page 115: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

67

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

4.4 Restart NE

The restart operation is a software reset and can be executed in normal traffic conditions.

The restart operation in any case activates the Commit (active) version.

Select the Restart NE option from the Supervision cascading menu.

The following dialogue box is opened.

Figure 30. Restart NE confirmation

Click on the OK push button to perform the restart NE.

Click on the Cancel push button to abort the restart NE.

Page 116: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

68

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 117: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

69

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

5 SECURITY MANAGEMENT

In this chapter are inserted setting options referred to the SECurity management:

5.1 Set Manager list

This option is referred to the SECurity management and allows the user to set the Manager list and theAccess Control Domain of the NE.

Select the Set Manager list option from the Supervision pull down menu.

The dialog–box contains the following fields:

– Manager list: each connected manager to the NE is highlighted in the list. The user can set amanager clicking on the denomination.Several manager can be enabled contemporaneously, having in charge the NE.The Manager List contains the list of managers ( i.e. RM, SY, NPOS , EML) that work on the NE.The EML–USM administrator (SH or Craft Terminal) should set the Manager List only to remove amanager in case of emergency (i.e. the Manager misses the NE connection).

– NE Domain field allow to select the domain among that displayed in the list, assigning it to the NE.The different domains could be assigned to different operators.

OK button is used to validate the selection.

Cancel button close the dialog without changes of the data.

Help button provides some useful information about the dialog.

Figure 31. Set Manager list

Page 118: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

70

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

5.2 Set ACD level

This option allows the user to select the level of the Access Control Domain.

The ACD manage the concurrence of access among several different managers (i,e. RM and EML).This only acts on the functions that can be used by different manager.

Select the Set ACD level option from the Configuration pull down menu.

The dialog–box contains the following fields:

– “Current ACD level “Show the Access Control Domain level currently set.

– The “Select new ACD Level”Permit to set one of three level checks. By the way, this is an operation that should be performed onlyduring the EML–USM installation phase:• Port Level• NE level, the ACD is performed on all the NEs• No Check, the ACD is not managedThe default value is NE level. If it is changed, it is necessary to restart the EML–USM.

OK button is used to validate the selection.

Close button close the dialog without changes of the data.

Figure 32. Set ACD level

Page 119: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

71

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

6 EXTERNAL INPUT AND OUTPUT POINTS MANAGEMENT

This chapter describes how to display and set the input/output environmental alarm (housekeeping alarm),

An external input point is an environmental alarm (also called housekeeping alarm). It corresponds to anexternal event which is monitored by the NE. Number of relays on the NE are dedicated to checkmodification of the environment as for example a fire, a flood ...

An external output point is used to manage a NE contact (i.e relay) connected to detector. An externaloutput point is independent from external input point.

The operations that can be undertaken in this section are:

– Displaying external points,

– Expanding or reducing external points list,

– Configuring input and output external points.

Note: the max. number of External Points depends by the equipment type (1640FOX, 1650SMC,1660SM) and board type were applicable ( example CONGI 3 Wire or CONGI 2 Wire boards equippedin 1650SMC and 1660SM); for details refer to the relevant Technical Handbook.

Page 120: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

72

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

6.1 Displaying external points

Select the External Points option from the Views pull down menu as shown in the following figure.

Figure 33. Opening the external points view.

After selecting this menu option the external points view is displayed into the current window instead ofthe current view.

Page 121: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

73

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LCA

Figure 34. External points view (example)

The external points view displays a list of all input and output points.

The following information is given for each external point:

– the external point Type: Input or Output.– the User Label: a user–friendly label associated to the configurable external point (see further the

paragraph External points configuration).– the External State: represents the alarm state. ”On” when the alarm is raised, else ”Off”. If the external

point is active (On), a little red flag is represented near the status of the concerned point.

Only for the “Output” external point there is the following information:

– the Output criteria: if configurated, display the alarm event and the board affected associated to theOutput point (see further the paragraph External points configuration).

Page 122: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

74

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

6.1.1 Expanding or reducing external points list.

The external points view displays a complete list of the external points but it can also be restricted to theinput or to the output points.

To see either the input points, the output points or all the external points, select the appropriate option fromthe External Points pull down menu as shown in the following figure.

Figure 35. Expanding or reducing the external points list.

Page 123: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

75

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

6.2 External points configuration

The configuration operations available on external points are:

• “user labels” configuration• “external state”. Can be set for output points (ON or OFF)• “Output criteria” associated to the External output point

To configure an external point, click on the concerned row of Figure 34. on page 73 and then select theConfiguration option from the External Points pull down menu as shown in the following figure.

Figure 36. Configuring external points.

The following dialogue boxes are then opened, displaying information about the selected external point(Input or Output).

Figure 37. External input point configuration dialogue box (example)

Page 124: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

76

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 38. External output point configuration dialogue box (MANUAL).

Figure 39. External output point configuration dialogue box (FLEXIBLE)

Page 125: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

77

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Opening the dialog the current state of the selected External Point is shown.

[1] External Input Point Configuration

• Type: In the field the name of the involved Input point is displayed (e.g. ExtP#8 in Figure 37. )

• User Label: this field can be filled by the user with a Label that indicate the associated eventthat must be taken under check (for example presences of water or fire in the room where theEquipment is placed)

• External State: this field is set to off and can’t be changed by the operator

• Probable Cause: this field is set to housekeeping and can’t be changed by the operator

[2] External Output Point Configuration

• Type: In the field the name of the involved Output point is displayed (e.g. ExtP#8 in Figure 38. )

• User Label: this field can be filled by the user with a Label that indicate the alarm detected orthe action that must be executed if a specific event occur (for example a “Pump” activation whenwater is present in the room where the equipment is placed)

• External State: can be set to “on” (alarm) or “off” (non alarm) only if “Manual” option has beenselected in the “Output Criteria” field.

• Output Criteria can be configured as :

– Manual (forced). The output contact is set in a fixed way , not depending on a particularevent.For example the output contact could be used to “Manually” activate a pump to drain waterfrom the room where the equipment is placed ; in this case is also necessary to set theoption “On” in the field “External State”.

– Flexible. It is possible to define from CT the couple event/CPO#, where the event ischosen between a set of Output Criteria (LOS, RDI and LOF) and specifies the STM–Ninterface which the Output Criteria refers to by clicking on Choose button; subsequentlythe TP search dialog box will be opened.

When the configuration of the external point is completed, click on the OK push button to validate thechoice and close the dialogue box. The Cancel push button cancels the configuration and closes thedialogue box.

Page 126: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

78

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 127: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

79

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

7 DIAGNOSIS MANAGEMENT

Alarms are always present on the operator’s workspace. The different types of alarms, their number and theirseverity level, are represented in all Equipment views (NE views, Board views and Port views). An iconrepresentation is used, which change color when the relevant alarm is active. Thus, at all times, you know thenumber of alarms and their severity relating to the equipment.Access to the Alarm Surveillance to show the alarm condition is detailed in the following paragraph.Than is presented the abnormal condition list (as result of operator’s command such us loop, laser forcedon etc.).At the end the Event log access is introduced.Information about the significance of equipment alarms and status is given in the Maintenancesection of this handbook.

7.1 Alarms surveillance

In this chapter is described the access to the Alarm Surveillance information of the NE.

It is possible to show all the Alarms or filter the alarms report.

Select the Diagnosis pull down menu. You can then select the following option from the Alarms pull downmenu (see the following figure):

– NE Alarms: all the NE alarms are listed in the Alarm Surveillance report which isactivated

– Object Alarms: only the alarms of the selected object are listed in the Alarm Surveillancereport

– Subtrees Alarm: only the alarms of the selected object and of the relevant subtrees arelisted in the Alarm Surveillance report

– Equipment Alarms: only the alarms of the equipment management are listed in the AlarmSurveillance report

– Transmission Alarms: only the alarms of the transmission management are listed in the AlarmSurveillance report

– External Points Alarms: only the alarms of the input external point management are listed in theAlarm Surveillance report

Figure 40. Alarm Surveillance

Page 128: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

80

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Selecting any of the previously seen options, the Alarm surveillance report is displayed as for the exampleof the following figure.

This view shows first a synthesis of the NE alarms (Counter Summary) with the sum of all alarms, thena detailed list of alarms of the selected filter (Alarms Sublist).

LCA

Figure 41. Alarm Surveillance (example)

Detailed information for each alarm is supplied.

For example the board in which the alarm is detected, the status of the alarm, the alarm type, the probablecause.

The information supplied help the operator, typically during troubleshooting operation, presented in nextsection of this handbook. (Maintenance section, where more details about alarms are given).

Detailed description is given in the AS Operator’s Handbook.

Page 129: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

81

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

7.2 Abnormal Condition List

The abnormal condition provides the synthesis of NE “not normal conditions” listinig the events thatcontribute to abnormal condition. Select Diagnosis–>Abnormal Condition List ( see Figure 42. on page81). Figure 43. on page 81 is opened.

Figure 42. Abnormal condition menu option

Figure 43. Example of abnormal condition list

The abnormal condition are the following:

• Loopback

• ALS is disable and the laser is forced on or off

• Protection units (in case of EPS, SNCP and MSP ) are in lockout or in forced status

• Board (or sub–board) is placed in a not configured slot

Page 130: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

82

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Select an abnormal condition and click on “OK” to open the relative dialog window. Figure 44. on page82 is opened.

Figure 44. Example of loopback dialog window management

The other abnormal condition types will open the corrisponding management window or will open thewindow to navigate towards the management window.

Page 131: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

83

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

7.3 Internal Link Monitor

The following description refers to the 1660SM equipment. The same description can beapplied to 1640FOX and 1650SMC taking into account the following rules:

– MATRIX (present in 1660SM) equivalent board in 1640FOX and 1650SMC is calledCOMPACT–ADM.

– 1640FOX can be equipped with only one COMPACT ADM board (main)

This function improves, at the user interface level, the diagnostic associated to the hardware failure.The presence of a failure on RX or TX side for the signal incoming/outgoing from/to the active MATRIXis detected.Internal Link Monitor displays a detailed localization of the link failure: a graphical representation of thestatus of the link among the active and stand–by MATRIX is shown.

Select the Internal Link Monitor option of the Diagnosis menu.

As shown in Figure 45. on page 84 the first page displays the link status for the main MATRIX, the secondone concern the spare MATRIX.

In detail, each page contains the following functional blocks and graphical objects:

• the tab of the page displays the user label of the MATRIX board;• the left side of the page displays the block representing the MATRIX board;• the right side of the page displays the list of blocks representing the equipped boards; each

block displays a string contained the user label of the associated board;• two arrows are displayed between the MATRIX block and each board block; the two arrows

represent the link status in Rx and Tx side:

– a red arrow indicates a ”link failure”– a green arrow indicates a ”working link”

• the Refresh button allows to perform an explicit refresh of all the displayed information.

In order to indicate all the possible roots of the ”link failure”, all boards that detect the link failure arerepresented by a red block in the page of the MATRIX main:

• a ”port” board is represented by a red block if a link problem is detected in the NGI Rx from theactive MATRIX;

• the MATRIX is represented by a red block if a link problem is detected in one of the NGI Tx fromone of the possible ”port” board.

Page 132: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

84

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 45. Internal Link Monitor (1660SM example)

Page 133: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

85

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

7.4 Log Browsing

From the Network Element context views, perform the following operations to have access to the EventLog file:

– In the Diagnosis pull–down menu, select the Log Browsing option. The following options areproposed:

Figure 46. Log Browsing option in Network Element context view

The proposed option:

• Select the Alarm Log option (Log Id # 1 ) to access the Event Log file.

The Configuration and Log Browsing ELB Windows open, permitting to analyze all alarmsstored in the NE.Refer to the “ELB Operator’s Handbook”

• Select the Event Log option (Log Id # 2 ) to access the Event Log file.

The Configuration and Log Browsing ELB Windows open, permitting to analyze all eventsstored in the NE.Refer to the “ELB Operator’s Handbook”

• Software Trace Log option is reserved to Alcatel personnel only.

Page 134: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

86

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

7.5 Remote Inventory

This paragraph describes the access to the remote inventory of this NE.In the Remote Inventory are stored information of identification, construction data ect.

The options used are:

– Upload Remote Inventory: store the Remote Inventory data in the Craft Terminal.

– View Remote Inventory: display the remote inventory data, previously stored in the Craft Terminalby means the “upload remote inventory” performed in the “Supervision” menu.

Remote Inventory option of the Equipment menu is instead presented in para. 9.6 on page 130.

7.5.1 Upload remote Inventory

This command stores the Remote Inventory data in the Craft Terminal.Select the Upload Remote Inventory option of the Supervision pull down menu.

The following confirmation dialog box is opened.

Figure 47. Remote Inventory confirmation request

Clicking on OK after a while an information dialog box is presented.

Figure 48. Remote Inventory completed

Page 135: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

87

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

7.5.2 View Remote Inventory

This command displays the remote inventory previously stored in the Craft Terminal by means the Uploadremote inventory.Select the View Remote Inventory option of the Diagnosis pull down menu.The Remote inventory data appears as for the following figure.

Figure 49. View Remote Inventory (example)

Data is displayed in specific fields:

• CompanyIt indicates the Company’s (Alcatel’s branch) which designs the unit.Refer to Alcatel for the abbreviation’s meaning (four characters).

• Unit TypeIt indicates the units’ acronym

• Unit Part NumberIt indicates Alcatel or Factory product’s Part No.. The number indicated is that printed on thelabels or on the units’ front coverplate.

• Software Part NumberIt indicates the id. of the unit’s resident software

Page 136: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

88

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

• CLEI CodeIt indicates the CLEI code according to Bellecore specs. TR–ISD–325

• Manufacturing plantIt indicates the Company’s manufacturing plant id. within the company, producing the unit.Refer to Alcatel for the abbreviation’s meaning (four characters).

• Serial NumberIt indicates the product’s serial number as specified by the NR 130 Norm.

• Date identifierIt indicates the meaning of the date that follow.It is a two–digit code supplying the following information:

00 date of construction at the time of final testing01 production order data02 construction date of the unit lot03 date product has been forwarded to customer04 customer order date

• Date (YYMMDD)The identification of the date depends on the indications stated in the previous field. When onlythe year is displayed, the format must be ”YY– – – – ”

Page 137: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

89

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8 COMMUNICATION AND ROUTING MANAGEMENT

8.1 Overview on Communication and Routing Domain

The purpose of the communication and routing domain is to define configuration parameters concerningthe communication protocols for the local NE, the OS and each other related NE in order to provide aglobal communication capabilities inside the network.

8.1.1 OSI Protocol on QB3/Qecc

A brief description of basic concepts and terms involved in the communication and routing domain follows.

During the TMN design process, a network is partitioned into domains; each domain can consist of acollection of two types of nodes:

• nodes supporting a link state routing protocol IS–IS; these nodes will be called adaptiverouters; IS–IS protocol floods the network with link state information in order to build a completeconsistent picture of the network topology. Use of IS–IS routing protocol in a TMN facilitatesinstallation and operation due to the ”self learning” capabilities of these protocols and automaticnetwork reconfiguration in case of failure; moreover the use of these standardized routingprotocols guarantees interoperability in a multivendor environment.

• nodes not supporting these protocols; these nodes will be called static routers;

Networks partitions consisting of the former type of node will be called adaptive routing domains;networks partitions consisting of the later type of node will be called static routing domains.

Moreover, a node which have to take routing decisions must became Intermediate Systems, all otherscan be made End Systems

For the description of the following paragraphs use is made of Figure 50. on page 90. It is not a networkplanning example, it is only used to describe L1 ,L2, RAP and MESA.

8.1.1.1 OSI Partitioning into Routing Subdomains

In order to reduce the overhead associated with distributed adaptive routing, it may be useful to dividea adaptive routing domain into smaller routing subdomains, called areas or level 1 subdomain. A level1 subdomain should fulfill the following requirements:

• a level 1 subdomain should form a connected subnetwork; this subnetwork should have onlya few links to the outside world, compared with the number of internal links;

• each node must belong to exactly one level 1 subdomain;• each node which is connected to a foreign level 1 subdomain must become a level 2

intermediate system; level 1 intermediate systems know how to communicate only with ISin the same area; obviously, there must be at least one level 2 intermediate system per level1 subdomain;

• Level 2 intermediate systems must form a connected network, because level 1 paths cannotbe utilized for level 2 communication. This network will be called level 2 backbone.

In the most simple case, all nodes within a level 1 subdomain share the same area address.In general it is allowed to have multiple synonymous area addresses within a level 1 subdomain even ifthe usage of this features should be checked with Alcatel engineers.The synonymous list is used to ease partitioning in the future. There is a basic rule, which must be followedby two neighboring level 1 intermediate systems within a subdomain: there must be at least one areaaddress in common between their two synonymous list, otherwise they are not able to communicate witheach other.

Page 138: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

90

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.1.2 OSI Partitioning into separate Routing Domains

In certain situations it may be necessary to partition a given network into separate routing domains, whereno routing information is exchanged between these domains. The major benefits of this partitioning arereduction of memory, processing and traffic overhead, because there is no exchange of routinginformation between the domains. Communication between separate routing domains must be achievedthrough the use of Reachable Address Prefixes (RAP).A Reachable Address Prefixes represents static routing information. It can only be associated with a linkof a level 2 intermediate system, whereby this link crosses routing domain boundaries. A ReachableAddress Prefixes is handled in the same way as information about a foreign level 1 subdomain within theown domain. The Reachable Address Prefixes indicates that any packet whose destination networkaddress NSAP matches the prefix may be forwarded via the link with witch the prefix is associated.

For example, consider network which is split into two separate routing domains:• routing domain A resides in a level 1 subdomain with area address ”a”• routing domain B resides in a level 1 subdomain with area address ”b”

In order to enable the communication, the Reachable Address Prefixes in routing domain A must containthe area address ”b” and the Reachable Address Prefixes in routing domain B must contain the areaaddress ”a”.On the other hand, within a given level 1 subdomain, there can be some NEs not supporting IS–IS norES–IS protocol (static routing). In such condition, the communication can be achieved through the useof Manual End System Adjacencies (MESA).A prerequisite for the use of manual end system adjacencies is that the area addresses of the connectednodes must be the same; as a consequence the nodes must belong to the same level 1 subdomain.Within a pure Alcatel network there is no need to use any kind of static routing. Therefore normally RAPand MESA shall never be used.

ÉÉÉÉ

AREA (subdomain) 1

AREA (subdomain) 3

AREA (subdomain) 2

= NE

L1

ÉÉÉÉ

= NE not supporting IS–IS

L1

L1

L1

L1

L1

L1

L1L2

L1

L1

L1

L1

L2L2

L2

ÉÉÉÉ

with MESA

with RAP

with MESA

L1

L1

L1

L1

L1

L1 L1 L1

L2 L2

Figure 50. Routing subdomain organization example

Page 139: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

91

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.1.3 IP over OSI tunneling for ISA board

This feature is applicable to NEs equipped with ISA boards (excepted ETHERNET and PR board)It permits to create a tunnel over OSI systems, to communicate IP management messages through anOSI network; it encapsulates the SNMP messages of the TCP/IP protocol stack over the OSI stack, usingCLNP,LAPD,ECC protocols, and an OSI address. In this way the message reaches its final destinationwithout repeated IP decapsulation/encapsulation in the intermediate nodes.

8.1.4 OSI over IP tunneling on QB3

This feature is not applicable to 1640FOX

This feature allows the Element Manager to reach the GNEs (and all the relevant NEs behind them) byusing IP networking.

This would permit to use an external DCN based on IP only. Hence, no OSI networking would be requiredon the external DCN.

OSI over IP technique is used to meet the target. OSI packets leaving the SH are encapsulated into IPpackets within the SH system itself. Hence, packets leaving the SH are IP packets, containing the originalOSI packet.

Once the packet get the NE through a pure IP network, the GNE has to strip off the IP encapsulation,extracting the OSI packet, and to route the OSI packet as it does today using a pure OSI networking.

Hence, the internal networking of the SDH network (DCCs) is still based on OSI. No IP packets shall flowinside DCCs, because the GNE receives the IP packet containing the OSI packet, deletes the IP header,and forwards only the OSI packet on DCCs.

The default OSI lower layers networking can be replaced by IP routing capability at the bottom of theQB3/QECC communication protocol suite; the choice is software switchable at NE level. Theimplementation adopts the RFC1006 standard to put the OSI upper layers on top of IP networking.

The application goal is to offer the TCP/IP transport (i.e. Internet compatibility) in alternative to the fullISO/OSI communication protocols, in the complete DCN network or at least in a consistent portion of it.

Figure 51. depicts the protocol architecture.

Page 140: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

92

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 51. OSI over IP tunneling on QB3

Page 141: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

93

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.2 Communication and routing views

To access select Comm/Routing option from the Configuration pull down menu as shown in thefollowing figure.

The Communication and Routing Views allows to perform the following operations:

• Local Configuration: definition of the local NE addresses

• OS Configuration: addressing of the main and spare OSs connected to the local NE

• NTP Server Configuration:addressing of the main and spare NTP servers connected to the local NE

• Interfaces Configuration subdivided in:

– LAPD Configuration: definition of the LAPD port parameters for each LAPD channelon the local NE

– Ethernet Configuration: definition of configuration parameters needed to manage a local NE which provides a LAN ethernet interface

• OSI Routing Configuration subdivided in:

– RAP Configuration: configuration of parameters necessary to the addressing of NEconnected by Reachable Address Prefixes in a domain differentfrom the one of the local NE. These information are stored in RAP table.

– MESA Configuration: configuration of parameters necessary to the addressing of nonIS–IS NE in the same domain as the one of local NE.These information are stored in MESA table.

• IP Configuration subdivided in:

– IP Static Routing Configuration: definition of Host/Network destination address for IPstatic routing

– OSPF area Configuration: definition of Open Shortest Path First address

– IP Address Config. of Point–to–Point interfaces: definition of the Equipment Controller IPaddress

– ISA board IP address: definition of the ISA board IP address

• Tunneling Configuration subdivided in:

– OSI over IP: definition of destination IP address for OSI over IP tunneling.This feature is not applicable to 1640FOX

– IP over OSI: definition of destination NSAP address and type of IP routing forIP over OSI tunneling

All the previously cited operation can be entered choosing the relevant option of the menu, as shown inthe Figure 52.

The options are described in next paragraphs.

Page 142: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

94

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 52. Comm/Routing options

Page 143: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

95

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.3 Local Configuration

Select the Configuration pull down menu. Select the Comm/Routing option and then from the cascadingmenu the Local Configuration option.

The dialog–box opens (Figure 53. ) and allows to configure the local address of the NE.

The following fields are present:

– a Local Address section contains the following graphical object:

• a Presentation Selector (P.Sel) identifies a presentation entity at the location identified by theNSAP Address. The presented value must not be modified.

• a Section Selector (S. Selector) identifies a section entity at the location identified by the NSAPAddress. The presented value must not be modified.

• a Transport Selector (T. Sel) identifies a transport entity at the location identified by the NSAPAddress. The presented value must not be modified.

• a Network Service Access Point (NSAP) Address identifies a location in the network. The firstfield of the NSAP address, AFI, determines the NSAP format.The AFI filed is 2 characters long (2 exadecimal digits) and, depending on the its value, thelength of NSAP address is variable from 16 characters to 40 characters:– the value of AFI 49 identifies the local format of variable length (from 16 characters to 40

characters).– the value of AFI 39 identifies the ISO–DCC format of 40 characters long.– the value of AFI 47 identifies the GOSIP–V2 format of 40 characters long.

Field after AFI: (optional: if not used must be all–zero), area address and organizationidentifier.

In all cases the last two fields of the NSAP address are:– System Id: uniquely identifies a NE in an area and is 12 characters long

It might be the equipment MAC Ethernet address, level 2, inserted in the NE (check thevalue in the para. 8.7 on page 102 ) or it might be selected by the operator.

– Network Selector: provides the distinction among users of the network service and is 2characters long (value is “1d”).

In the view, the NSAP is managed as simple strings of characters without any pre–formattingbecause of the variable format:– a first string of two characters that identifies the AFI field– a second string of variable length that identifies the remaining NSAP address

– Synonymous Area Addresses section allows to have multiple synonymous area addresses within alevel 1 subdomain. The compilation of the two network addresses is optional and if they are inserted,the last two fields, System Id and Network Selector, of the mandatory address and of the synonymousaddresses must be the same.

– System Type section determines whether the local NE acts as a “intermediate system level 1” or asa “intermediate system level 2” or as a “End System”. Note that a level 2 intermediate systemperforms functions of a level 1 too. End System is not operative.

Ok button is used to perform a configuration change of the data contained in the dialog–box and closesit; the dialog is visible until the end of the operations and a wait cursor is displayed.

Cancel button close the dialog without changes of the data.

Help button provides some useful information about the dialog.

Page 144: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

96

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 53. Local Configuration

Page 145: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

97

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.4 OS Configuration

Select the Configuration pull down menu. Select the Comm/Routing option and then from the cascadingmenu the OS Configuration option.

The dialog–box opens (Figure 54. ) and allows to configure the addresses of the Main and Spare OSsconnected to the local NE.

The following fields are present:

– Main OS Address section contains the same graphical object of the Local Address Section in theLocal Configuration dialog–box.

– Spare OS Address section contains the same graphical object of the Local Address Section in theLocal Configuration dialog–box.

Ok button is used to perform a configuration change of the data contained in the dialog–box and closesit; the dialog is visible until the end of the operations and a wait cursor is displayed.Cancel button close the dialog without changes of the data.Help button provides some useful information about the dialog.

Figure 54. OS Configuration

Page 146: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

98

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.5 NTP Server Configuration

Select the Configuration pull down menu. Select the Comm/Routing option and then from the cascadingmenu the NTP Server Configuration option.

The dialog–box opens (Figure 55. ) and allows to configure the addresses of the Main and Spare NTP(Network Protocol synchronization Time) Servers connected to the local NE, used for time distribution inthe network.

The following fields are present:

– Enabling NTP Protocol section allows to enable or disable the NTP Protocol.

– Main NTP Server Address section contains the same graphical object of the Local Address Sectionin the Local Configuration dialog–box.

– Spare NTP Server Address section contains the same graphical object of the Local Address Sectionin the Local Configuration dialog–box.

If the NTP server is coincident with the OS (same hardware), the same NSAP address of the OS must beassigned.

Ok button is used to perform a configuration change of the data contained in the dialog–box and closesit; the dialog is visible until the end of the operations and a wait cursor is displayed.Cancel button close the dialog without changes of the data.Help button provides some useful information about the dialog.

Figure 55. NTP Server Configuration

Page 147: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

99

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.6 LAPD Configuration

Select the Configuration pull down menu. Select the Comm/Routing–>Interfaces Configurationoption and then from the cascading menu the LAPD Configuration option.

The ”LAPD Configuration” dialog opens (see Figure 56. on page 100, this example has one LAPDInterface configured).It contains the following functional block and graphical objects:

– a section named LAPD Interfaces List that allows the user:

• to display the list of configured LAPD Interfaces using a graphical table;• to change the role of the LAPD Interface selected in the LAPD Interface List;• to delete the LAPD Interface selected in the LAPD Interface List;• to create a new LAPD Interface.

This section contains the following graphical objects:

• the number of LAPD interface displayed in the LAPD Interface List;• the LAPD Interface List that lists all the configured LAPD Interfaces; for each LAPD Interfaces,

the table displays:– the user label of the TTP containing the configured LAPD Interface (MS/RS TTP);– the LAPD role that contains one of the following value:

• User (one end of the link)• Network (the other end of the link)

• Delete button that allows to delete the LAPD Interface selected in the LAPD table;• Change Role button that allows to change the role (User or Network) of the LAPD Interface

selected in the table (after selection the Figure 58. on page 101 is shown to confirm actionrequired);

• Create button that allows to create a new LAPD Interface; this button starts a new dialog (seeFigure 57. on page 101) named Create LAPD Interface; it is disabled when the maximumnumber of LAPD Interface has been configured.This Create LAPD Interface dialog contains the following functional blocks and graphicalobjects:

– a Choose button that allows the operator to select the superior TTP of the LAPD Interfaceto be created; this button starts the TP Search dialog; the TP Search dialog will beconfigured in order to display in the right tree only the allowed TTP of the LAPD Interfacei.e. RS–TTP or MS–TTP;

– a section LAPD Role that allows to configure the role (User or Network) of the LAPDInterface to be created.This connection is a must to establish end–to–end connection between two NE’s: if oneend is configured with User role, the other end connected must be configured with Networkrole.

– a section named Search Criteria that allows the user to display only the LAPD’s of the selected typein the LAPD Table; the section contains the following graphical objects:

• the field Interface Type that allows to select the type of the LAPD’s to be displayed in the LAPDTable; the field will manage both ADM and WDM DCC type; the value ”Ignore” will allow todisplay all the LAPD types;

• the Search button starts the search of the selected LAPD type; this buttons can be used torefresh the LAPD table too.

Page 148: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

100

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The LAPD Interface List will be updated on reception of the Delete/Create/Change DCC CTPnotification. If no LAPD Interface are configured in the equipment, the message ”No LAPD Interface”will be displayed near LAPD Interface counter (that it is at zero).

Figure 56. LAPD Configuration dialog (example)

Close button close the dialog without changes of the data.

Page 149: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

101

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 57. Creation LAPD Interface

Figure 58. Confirmation to change LAPD Role

Page 150: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

102

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.7 Ethernet Configuration

This feature is not applicable to 1640FOX

Select the Configuration pull down menu. Select the Comm/Routing –> Interfaces Configurationoption and then from the cascading menu the Ethernet Configuration option.

The dialog–box opens (Figure 59. ) and allows to define the parameters needed to manage a NE whichprovides a LAN ethernet interface .

The following fields and data are present:

– Ethernet Interface field allows to define or remove a Local Area Network Port for the access to theData Communication Network.

– MAC Address section allows to display the address of the Network Element in the Ethernet LAN;it is a read–only field.

– OSI Section:

• L2 only Parameter field indicates if the port shall be used for level 2 traffic only, thus avoidingtransmitting L1 packets. Note that the flag shall be set to No if some other nodes (NEs or OSs)of the same area of the relevant NE are connected to the Ethernet.One example is indicated in Figure 60. on page 103.

• L1 Default Metric is a not modifiable field , Priority field can be set ( default value for ethernetis 64)

• L2 Default Metric is a not modifiable field , Priority field can be set ( default value for ethernetis 64)

– IP Section section allows to define the “node” IP Address, IP Mask and the Routing IP Protocol used;If “OSPF” or “Both” options of Routing IP Protocol field are selected, also the “Associated OSPFArea” must be set.

Apply button performs a configuration change of the data.

Close button close the dialog without changes of the data.

Page 151: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

103

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 59. Ethernet Configuration

L2 L2

NENo

AREA 1

AREA 2

AREA 3

LAN

NENo

L2

NEYes

OS

Figure 60. Ethernet Configuration – L2 only parameter

Page 152: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

104

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.8 Reachable Address Prefixes Configuration

Select the Configuration pull down menu. Select the Comm/Routing –> OSI Routing Configurationoption and then from the cascading menu the RAP Configuration option.The dialog–box opens (Figure 61. ) and allows to configure the Reachable Address Prefix table.Each element of the RAP table allows to link a LAPD port or a LAN port of the local NE to a separatedomain; the separate domain is selected by the address Prefixes. If the addressed element is the OS, theLAN port will be used.The view simulates a real notebook; it allows the user to select the pages of the notebook using the pointingdevice (upper part of the figure); each page represents a particular element of the RAP table and therespective pointing device displays the element counter.

In detail, each page contains the following data:– Physical Interface button

• if the element is empty, displays the ”none” value and allows to select a LAPD ports or a LANport which will be used to reach the addressed area.

• if the element isn’t empty, displays the selected port and allows to change it.– Area Address Prefix section allows the user to address the separate domain. The Area Address

Prefix represents a NSAP address without the fields System Id and Network Selector.– MAC Address section allows to address the element of a domain to be reached the Ethernet LAN;

the field is managed as a simple strings of 12 digit.

Apply button is used to perform a configuration change of the data contained in the complete RAP tableand close the view; the view is visible until the end of the operations and a wait cursor is displayed.New button is used to insert a new page.Delete button is used to delete the selected page.Close button close the dialog without changes of the data.

Figure 61. RAP Configuration

Page 153: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

105

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.9 Manual ES Adjacencies table Configuration

Select the Configuration pull down menu. Select the Comm/Routing –> OSI Routing Configurationoption and then from the cascading menu the MESA Configuration option.The dialog–box opens (Figure 62. ) and allows to configure the Manual ES Adjacencies table.Each element of the MESA table allows to link a LAPD port or a LAN port of the local NE to a End Systemelement; the ES element must be in the same area as the one of the local NE. If the addressed elementis the OS, the LAN port will be used.The view simulates a real notebook; it allows the user to select the pages of the notebook using the pointingdevice (upper part of the figure); each page represents a particular element of the MESA table and therespective pointing device displays the element counter.

In detail, each page contains the following data:– Physical Interface button

• if the element is empty, displays the ”none” value and allows to select a LAPD ports or a LANport which will be used to reach the End System element.

• if the element isn’t empty, displays the selected port and allows to change it.– System Id section represents the System Id of the ES element.– MAC Address section allows to address the element in the Ethernet LAN; the field is managed as

a simple strings of 12 digit.

Apply button is used to perform a configuration change of the data contained in the complete MESA tableand close the view; the view is visible until the end of the operations and a wait cursor is displayed.New button is used to insert a new page.Delete button is used to delete the selected page.Close button close the dialog without changes of the data.

Figure 62. MESA Configuration

Page 154: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

106

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.10 IP Configuration

The options listed in the menu Configuration –> Comm/Routing –> IP Configuration and also inConfiguration –> Comm/Routing –> Tunneling Configuration are relevant to the configuration ofmessages communications for the management of ATM or PR_EA boards (ISA) inside the equipment andin the network.

8.10.1 IP routing configuration for ISA boards management

In order to manage the ISA boards (excepted ETHERNET and PR boards) inserted into the equipment,the following operations are to be done:

• “IP Address Configuration of Point–to–Point Interface” (see para 8.13 page 109), definesthe IP address for the Equipment–Controller (EC). This should be the first addressing operation

• routing configuration, by means of the options:– “IP Static Routing Configuration” (see para 8.11 page 107), if using static routing– “OSPF Area Configuration” (see para 8.12 page 108), if using the automatic OSPF

routing

• “ISA Board IP Address” (see para. 8.14 page 110), it defines the IP address for the ISA boards;it is to be defined for every ISA board hosted by the equipment.NOTE: if the ISA boards are in EPS 1+1 configuration (not applicable to 1640FOX), they musthave the same address)

• “IP over OSI Tunneling” (see para. 8.16 page 112), it defines the OSI address (NSAP) of thedestination node to be reached (for instance the GNE connected to the TMN), when the ATM/IPmanagement message passes through an SDH/OSI network; i.e. it is to be done for everySDH–NE of the network, if equipped with ISA boards.NOTE: this addressing must be carried out at both end nodes of the tunnel, so that they cansee each other.

• “OSI over IP Tunneling” (not applicable to 1640FOX), it defines the IP address of thedestination node to be reached (for instance the IP router where the TMN is connected), whenan OSI management message passes through an IP network. It is to be defined on a a GatewayNetwork Element (GNE) equipped with the QB3 interface, where the QB3 is connected to aLAN/IP network.NOTE: this addressing must be carried out at both end nodes of the tunnel, so that they cansee each other.

Page 155: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

107

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.11 IP Static Routing Configuration

Select the Configuration pull down menu. Select the Comm/Routing–>IP Configuration and then fromthe cascading menu, the IP Static Routing Configuration option.The dialog–box opens (Figure 63. ) and allows to configure the parameters for IP Static RoutingConfiguration.

The following fields and data are present:

[1] Destination Host IP Address: allows to define the IP address necessary to reach a specific Host

[2] Destination Network: it is alternative to Destination Host IP Address; allows to define theIP Address and IP Mask to reach a network.

[3] Default Gateway IP Address: allows to define the address of the next hop gateway

[4] CLNP (Connection Less Network Protocol): allows to use a pre–define IP over OSI tunnel towardsa gateway. The information in the field is automaticallyassigned after the execution of the option “IP over OSITunneling” (see para. 8.16 page 112).

[5] IP Point–to–Point Interface Id: allows to use point to point interfaces made available by EC

N.B. Points from [3] to [5] are alternative

Apply button is used to perform a configuration change of the data contained in the complete table andclose the view; the view is visible until the end of the operations and a wait cursor is displayed.New button is used to insert a new page.Delete button is used to delete the selected page.Close button close the dialog without changes of the data.

Figure 63. IP Static Routing Configuration (example)

Page 156: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

108

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.12 OSPF Area Table Configuration

Select the Configuration pull down menu. Select the Comm/Routing–>IP Configuration and then fromthe cascading menu, the OSPF Area Table Configuration option.The dialog–box opens (Figure 64. ) and allows to configure the parameters for OSPF (Open Shortest PathFirst) Area Table Configuration , i.e. it is used in an IP network in automatic, dynamic OSPF routingconfiguration. More area addresses may be set; in this case new pages are created by the system.

The following fields and data are present:

– OSPF Area IP Address: it is the address of the area containing the equipment

– OSPF Area Range Mask

Both fields gives a synthetical information that includes all the addresses (specific to a NE and to aNetwork) in an Area.

Apply button is used to perform a configuration change of the data contained in the complete RAP tableand close the view; the view is visible until the end of the operations and a wait cursor is displayed.New button is used to insert a new page.Delete button is used to delete the selected page.Close button close the dialog without changes of the data.

Figure 64. OSPF Area Table Configuration (example)

Page 157: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

109

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.13 IP Address Configuration of Point–to–Point Interfaces

Select the Configuration pull down menu. Select the Comm/Routing–>IP Configuration and then fromthe cascading menu, the IP Address Configuration of Point–to–Point Interfaces option.The dialog–box opens (Figure 65. ) and allows to set the Equipment Controller IP Address used tocommunicate with the ISA boards inserted into the equipment, and with the rest of the network.

Ok button is used to perform a configuration change of the data contained in the dialog–box and closesit; the dialog is visible until the end of the operations and a wait cursor is displayed.

Cancel button close the dialog without changes of the data.

Figure 65. IP Address Configuration of Point–to–Point Interfaces (example)

Page 158: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

110

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.14 ISA board IP Address

Select an ISA board of the equipment and then the Configuration pull down menu. Select theComm/Routing–>IP Configuration and then from the cascading menu, the ISA Board IP Addressoption.The dialog–box opens (Figure 66. ) and allows to set the IP Address of the ISA Board that communicatewith the Equipment Controller (EC).

Ok button is used to perform a configuration change of the data contained in the dialog–box and closesit; the dialog is visible until the end of the operations and a wait cursor is displayed.

Cancel button close the dialog without changes of the data.

Figure 66. ISA Board IP Address (example)

Page 159: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

111

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.15 OSI over IP

This feature is not applicable to 1640FOX

Select the Configuration pull down menu. Select the Comm/Routing–>Tunneling Configuration andthen from the cascading menu, the OSI over IP option.The dialog–box opens (Figure 67. ) and allows to configure the Remote Destination IP Address of theEquipment Controller.

Figure 67. OSI over IP Tunneling configuration (example)

Apply button is used to perform a configuration change of the data contained in the complete table andclose the view; the view is visible until the end of the operations and a wait cursor is displayed.New button is used to insert a new page.Delete button is used to delete the selected page.Close button close the dialog without changes of the data.

Page 160: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

112

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

8.16 IP over OSI

Select the Configuration pull down menu. Select the Comm/Routing–>Tunneling Configuration andthen from the cascading menu, the IP over OSI option.The dialog–box opens (Figure 68. ) and allows to configure the Destination NSAP Address and the IPRouting Type; i.e. it permits the TMN to reach the ATM/IP boards inserted into the SDH/OSI network . Moretunneling channels may be created, in these cases new pages are created by the system.

The following fields are present:

– Destination NSAP Address:(OSI address of the NE ending the tunnel)

a Network Service Access Point (NSAP) Address identifies a location in the network. The firstfield of the NSAP address, AFI, determines the NSAP format.The AFI filed is 2 characters long (2 exadecimal digits) and, depending on the its value, thelength of NSAP address is variable from 16 characters to 40 characters:– the value of AFI 49 identifies the local format of variable length (from 16 characters to 40

characters).– the value of AFI 39 identifies the ISO–DCC format of 40 characters long.– the value of AFI 47 identifies the GOSIP–V2 format of 40 characters long.

In all cases the last two fields of the NSAP address are:– System Id: uniquely identifies a NE in an area and is 12 characters long

It might be the equipment MAC Ethernet address, level 2, inserted in the NE (check thevalue in the para. 8.7 on page 102 ) or it might be selected by the operator.

– Network Selector: provides the distinction among users of the network service and is 2characters long (value is “1d”).

In the view, the NSAP is managed as simple strings of characters without any pre–formattingbecause of the variable format:– a first string of two characters that identifies the AFI field– a second string of variable length that identifies the remaining NSAP address

– IP Routing:allows to choose the type of IP routing supported as follows;– OSPF (Open Shortest Path First) , if the “OSPF Area Configuration” option has been used

(see para 8.12 page 108)– RIP (Routing Information Protocol)– Both– None, if the option “IP Static Routing Configuration” (see para 8.11 page 107) has been

used

If “OSPF” or “Both” options are selected, also the “Associated OSPF Area” must be set (it is tobe chosen among the presented options); in this case the information field is automatically filledwith the addresses set in the “OSPF Area Configuration” application.

Apply button is used to perform a configuration change of the data contained in the complete table andclose the view; the view is visible until the end of the operations and a wait cursor is displayed.New button is used to insert a new page.Delete button is used to delete the selected page.Close button close the dialog without changes of the data.

Page 161: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

113

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 68. IP over OSI Tunneling configuration (example)

Page 162: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

114

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 163: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

115

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

9 EQUIPMENT MANAGEMENT

9.1 Introduction and navigation

This section deals mainly with the setting and changing of the boards present on the Equipment andundertaking board protection operations.

Using the menu options, select the Equipment option from the View pull down menu

The first level of the “Equipment Overview” representation will be displayed directly into the current window(see the following figures).The Equipment Overview enables a fast navigation through all levels of theequipment hierarchy. Navigation is done from higher to lower levels.

The NEs hierarchy is different organized according to the equipment type, as follow:

– 1660SM & 1650SMC:

Subrack > board > port > TP

The navigation through different levels of the NE hierarchy is performed by double clicking on theobjects (see also para 9.1, pg. 115):

• the first level shows the subrack level of the Equipment view (see Figure 69. on page 117);• by double clicking on a board body , the board level of the Equipment view can be reached (as

described in chapter 10 on page 133).• further, by double clicking on a port body contained in the board, the port level of the Equipment

view can be reached (as described in chapter 11 on page 139). The port view displays the innerTPs.

• it is possible to go back to the upper level of representation by pressing the <ESC> key on thekeyboard;It is also possible to:– go back to the previous view, by selecting the Backward option from the views menu– go to the next view, by selecting the Forward option from the view menu.

N.B. Selecting in the first level of the Equipment view ( subrack level, see Figure 69. on page117 ) the Show supporting equipment option from the Equipment menu, the Rack levelview of Figure 70. is presented.

In the Rack Level view two subracks are presented:

– at the top the Equipment Subrack (example “SR60M” for 1660SM or “SR50C” for1650SMC)

– at the bottom the Fans Subrack, named SRFAN.The Fans Subrack presence is managed with the Set option as for the boards of theEquipment Subrack (refer to paragraph 9.2 on page 122 for details)

Further, selecting in the Rack level view the Show supporting equipment option from theEquipment menu, the Equipment level view of Figure 71. is presented.

Page 164: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

116

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– 1640FOX:

Rack > Subrack > board > port > TP.

The navigation through different levels of the NE hierarchy is performed by double clicking on theobjects (see also para 9.1, on page 115):

• the first level shows the Rack level of the Equipment view (see Figure 72. on page 119); twosubracks are presented:

– at the top the Equipment Subrack “SR40M”– at the bottom the AC/DC Rectifier Subrack, named “SR40R”

by double clicking on a Subrack body, the relevant subrack level of the Equipment view can bereached (see Figure 73. on page 120).

• by double clicking on a board body, the board level of the Equipment view can be reached (asdescribed in chapter 10 on page 133).

• further, by double clicking on a port body contained in the board, the port level of the Equipmentview can be reached (as described in chapter 11 on page 139). The port view displays the innerTPs.

• it is possible to go back to the previous level of representation by pressing the <ESC> key onthe keyboard; or:– go back to the previous view, by selecting the Backward option from the Views menu– go to the next view, by selecting the Forward option from the Views menu.

N.B. Selecting, in the first level of the Rack view (rack level ), the Show supporting equipmentoption from the Equipment menu, the Equipment level overview is presented (see Figure 74. on page 120).

Page 165: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

117

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

1650SMC

1660SM

LCA

LCA

Figure 69. Equipment Overview – 1650SMC and 1660SM “Subrack“ level

Page 166: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

118

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

1650SMC

1660SM

1650SMC

1660SM

without Fans Subrack with Fans Subrack

without Fans Subrack with Fans Subrack

SR50C

SRFAN

SR60M

SRFAN

LCA LCA

LCA LCA

Figure 70. Equipment Overview – 1650SMC and 1660SM “Rack” level

Page 167: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

119

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

1650SMC 1660SM

LCALCA

Figure 71. Equipment Overview – 1650SMC and 1660SM “Equipment level”

1640FOX

LCA

Figure 72. Equipment Overview – 1640FOX“Rack” level

Page 168: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

120

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

1640FOX

LCA

Figure 73. Equipment Overview – 1640FOX “Subrack“ level

1640FOX

LCA

Figure 74. Equipment Overview – 1640FOX “Equipment level”

Page 169: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

121

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The “equipment management” is achieved by using the options offered by the Equipment menu (seeFigure 75. page 121).

Alarms indications are present at every NE level.Details about these alarms indications are given in the Maintenance section.

All the options offered by equipment menu are described in the next paragraphs.

The main functions are the setting and changing of the boards on the Equipment.Boards administrative state settings, that decide about the “in/out of service” of the boards is alsodescribed.

Figure 75. Equipment menu (example)

Equipment setting operation are defined according the following sequences:

– configuration of a new board• Configure the board using the option “Set”

– change of board type• “Set out of service” the board• Configure the board using the option “Set”

– remove a board• “Set out of service” the board• Delete all the underlying traffic, connections, services, etc. concerning the board• “Remove” the board.

Page 170: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

122

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

9.2 Set and change or remove board/subrack

The boards can be set, changed or removed using the menu options of the Equipment view.

a ) Setting or changing a board/subrack

A new board/subrack may be created in either an empty slot or it may replace an existing Out ofService board/subrack (without the lock symbol). In fact, the Set option is available only afterselecting an empty slot or an Out–of–service board.

• Click on the empty slot in which a board/subrack has to be added, or on an existing Out ofService board in order to change it (see next para. 9.4 on page 128 for “in /out of service” info).The contour becomes highlighted to show that operations can be done on it.

• Select the the Set option of the Equipment pull down menu of Figure 75. on page 121.

• The following example of dialogue box containing a list of the different types of boards/subrack/access card and modules is displayed.

Page 171: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

123

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

BOARDS LIST

ACCESS CARD LIST

SUBRACK LIST

MODULES LIST

Figure 76. The list of different boards/subrack relative to an NE slot (examples)

Page 172: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

124

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

NOTE: The list of boards/subrack displayed during a ”Set” operation is restricted to those which theequipment may accept in the selected slot. Therefore the list will vary depending on which slot hasbeen selected.For details on the board/subrack identified by acronyms and NE physical composition please refersto the Technical Handbook.

• Choose the board/subrack/access card type required, by clicking on the corresponding item inthe list. The name of the board is highlighted. Click on the OK push button to validate the choice.Note: In case of 4xANY Modules it is also necessary to choose the type of user supported asshown in Figure 76.

• The board/subrack representation appears on the NE view in the slot when the board changeis effective.A lock representation appears over the boards (”in–service”, see next para. 9.4 on page 128)

• In the Create/Modify dialogue box, the Cancel push button cancels the operation and closesthe dialogue box. The Help push button opens a Help view giving information about the context.

b ) Removing a board/subrack/modules

NOTE: the “Remove” action is not possible in the case that, on the considered board, is still existing anyoperation/connection/termination on the underlying supported signals, such as:• Performance Monitoring on underlying TPs• POM / TCT /TCM /SUT monitoring operations• Lower order Connections• Higher order Connections• Lower/Higher order Path Terminations• Loop–backs• LAN/LAPD (and any comm/routing service)• Auxiliary channels• Timing Sources References• Daughter boards, Submodules, etc.Thus the deletion of every operation/connection/termination is necessary, in the same order as abovelisted, before removing a board.

• Click on the board/subrack to remove (Out of Service board/subrack, as for next para. 9.4 onpage 128).

• The outline of the slot becomes highlighted. This indicates that the board is selected and thatoperations can be done on the slot.

• If the slot you are working on is already empty no name appears under the slot.

• Select the Remove option the Equipment pull down menu of Figure 75. on page 121.

• From the confirmation dialogue box that opens you can confirm or cancel the ”Remove” operation.

Page 173: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

125

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

c ) Modify a board

NOTE: this procedure can be done to replace an existing unit with a similar one of different version,without previously remove it. In other words: it is possible when changing only the version of theboard, not the type.

– Click on the optical module to replace. The outline of the slot becomes highlighted to show thatoperation can be done on it.

– Select the Modify option of the Equipment pull down menu of Figure 75. on page 121 .

– A dialog box containing a list of different types of optical module is displayed.

– Chose the optical module type required by clicking on the corresponding item in the list; the nameof the module is highlighted.

– Click on OK push button to validate the choice.

– The board representation appears on the N.E. view in the slot when the board change is effective.A padlock representation appears over the board.

Page 174: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

126

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

9.3 Connect Fan to CONGI board

This feature is not applicable to 1640FOX

This command enable the Fan Subrack alarms management by means of a connection to a CONGI board.

The option menu is different according to the equipment type (1650SMC or 1660SM) as explained in thefollowing table:

Equipment Type Options available

1650SMC Connect Fan to CONGI#5

1660SM Connect Fan to CONGI#10

Connect Fan to CONGI#12

NOTE: even if available, this option must not be used!

Figure 77. shows an example of connection for 1660SM equipment; the description that follows can beapply also to 1650SMC taking into account that the option to be chosen is “Connect Fan to CONGI#5”.

Select the CONGI board

To enable this function select the option (Connect Fan to CONGI#10 ) of the Equipment menu

LCA

Figure 77. Connect FAN to CONGI

It is possible to disable this function by selecting the relevant CONGI board and than choosing theRemove Fan connection from CONGI#10 option of the Equipment menu (refer to Figure 78. ).

Page 175: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

127

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LCA

Figure 78. Remove FAN connection from CONGI

Page 176: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

128

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

9.4 Board administrative state

The operator decides to set a board in service or out of service, if it is allowed by the NE.

N.B. In the equipment view, a lock representation appears over the boards which are in ”in service”

state.

9.4.1 Setting a board in service

– In the Subrack NE view, click on the board in order to select it.– Select the Set in service option of the Equipment pull down menu of Figure 75. on page 121.

A lock representation appears over the boards.

9.4.2 Setting a board out of service

– In the Subrack NE view, click on the board in order to select it.– Select the Set out of service option of the Equipment pull down menu of Figure 75. on page 121.

Select the Ok push button in the confirmation window which appears.

A lock representation disappears, substituted by the symbol over the boards..

9.4.3 Consulting a Board’s Administrative state

The board’s administrative (”in service” or “out of service”) state is indicated on the board view as shownin the following figure.

Administrative

State Information

LCA

Figure 79. Consulting a board’s administrative state (example)

Page 177: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

129

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

9.5 Software description

This function allows the operator to visualize information about the software(s) which is (are) present in theselected board.

– Click on a board in which the software is wanted to know (EQUICO or MATRIX unit for “1660SM”,SYNTH unit “for 1650SMC and 1640FOX”). The outline of the slot becomes highlighted. Thisindicates that the board is selected and that operations can be done on the slot.

– Select the Software description option of the Equipment pull down menu of Figure 75. on page121.

The following window opens.

Figure 80. Software Description dialogue box (example)

The dialogue box contains as many folder sheets as there are softwares in the selected board.

If the selected board does not contain any software, the following information will be displayed:

Click on the Close push button to close the dialogue box.

Page 178: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

130

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

9.6 REMOTE INVENTORY

This command displays the remote inventory data present in the Subrack and Boards.– Select the Remote Inventory option of the Equipment pull down menu.

Two options are available (see the following figure):• Subrack level: prints or write on a file the remote inventory data of the subrack.• Board level: show the remote inventory data of the selected board

For the Board level a dialog similar to Figure 81. appear.

Figure 81. Remote Inventory (example)

Page 179: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

131

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The remote inventory data of the Subrack level can be printed on the default printer ( Figure 82. ) or to afile in postscript or ASCII format ( Figure 83. ).

Figure 82. Select Printer

N.B. If no printer is installed, there is no error message displayed to indicate this.

Figure 83. Select Output Format for file

Page 180: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

132

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

9.7 Show supporting equipment

Click on Show Supporting Equipment menu option of the Equipment menu to navigate to theequipment that supports the selected board.

Figure 84. (example) opens.

LCA

Figure 84. Equipment Overview – Subrack level (example)

Page 181: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

133

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

10 BOARD VIEW

10.1 Introduction

The Board View permits to show the physical port available in a specific board and to access the Portview.

The “Board view” is reached selecting the Equipment option in the View pull down menu, then doubleclicking on the selected board to show the relevant Board view, presenting the ports.

In case of board containing “sub–boards”, another view permits to see the contained item, named“daughter” or “sub–board” (see example of Figure 85. )

An example of “daughter” with the presented port is in Figure 86. It is displayed after clicking on it.

Alarms and Status indications referred to the board level are present at the bottom of the view, as indicatedin the example (Administrative State and Board Alarms/Status).

This information are “In/Out of service” of the board (Administrative State) and board alarms and statuslike “missing” (RUM) or “mismatch” (RUTM), EPS condition if supported and other indications typical ofeach unit .

In the Maintenance section details on this indication are given.

Administrative stateBoard Alarms/Status

”daughters”

LCA

Figure 85. Equipment view: select the SDH port on a board (example)

Page 182: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

134

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LCA

Figure 86. Example of a Board View

A port type is described with a board rectangular view and a port identification.

The port identification is usually internal to the rectangular board (see Figure 87. some ports examples).

(SDH) (ISA) (PDH) (GBit ETHERNET) (ISA–ES)

Figure 87. Examples of a Ports identification and relevant alarm synthesis

The following information is available:

– type of port (name)– state of port (alarm status synthesis)– symbol of the port

The operator is provided with a representation of the port alarm synthesis on each port.

The messages displayed at the top view provide port denomination.

The messages displayed at the bottom provide information about Board alarms.

A message under the mouse facility provides the name and the port type or the alarms name. A messageappears in the message area in the bottom left corner of the view.By double clicking on a board view, it is also possible open the corresponding port view (see chapter 11on page 139).

Page 183: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

135

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

10.2 Board View Menu

Selecting the “Board” option in the menu bar of Figure 86. on page 134 the complete pull down Boardmenu is presented (Figure 88. ):

– Port Access: Access the “Port” view. See para.10.2.1 on page 136 .Note: this option is accessible after the selection of a port containedin the view.

– Change Physical Interface: Change the SPI or PPI object into PPI or SPI (and viceversa) on thebi–mode port( 140Mbit/s / STM–1 switchable).See para. 10.2.2 on page 137.

This feature is not applicable to 1640FOX

– Show supporting equipment: Navigate to the upper subrack level.See para.10.2.3 on page 138.

– ISA Port Configuration: It allows to configure the TPs for the ISA port connections.Note: this is available only if an ISA board has beenequipped in the Subrack.

Figure 88. Board menu options

These options are described in next paragraphs.

Page 184: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

136

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

10.2.1 Port Access

Click on Port Access option of the Board menu to access the “Port View” ( see chapter 11 on page 139).

Navigation to the Port view permits to show a detailed alarm presentation of the port and to set the relevantconfigurations as for the example of the following figure.

Note: on the ISA port the TPs are not automatically created (except for MAU TP) when the board isequipped in the subrack but they must be created with the aid of the Configuration –>ISA portConfiguration (refer to Chapter 20 on page 427).

LCA

Figure 89. After “Port Access” selection (example)

Page 185: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

137

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

10.2.2 Change Physical Interface

This feature is not applicable to 1640FOX

This command allows to change the type of physical interface in a bi–mode port (140 Mbit/s / 155 Mbit/sswitchable port) i.e it changes the SPI or PPI object into PPI or SPI.

Select the Symbol of the port in the “Board view”.

Click on Change Physical Interface menu option of the Board menu (see Figure 90. on page 137)

LCA

Figure 90. Change Physical Interface (example)

The following dialog box is opened:

Click on the OK push button to change the physical interface.

Click on the Cancel push button to abort the change of the physical interface.

Page 186: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

138

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

10.2.3 Show Supporting equipment

Click on Show Supporting Equipment menu option of the Board menu to navigate to the subrack thatsupports the selected port view.Figure 91. (example) opens.

LCA

Figure 91. Subrack level (example)

Page 187: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

139

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11 PORT VIEW

11.1 Introduction

This section describes the operations necessary for the consultation, modification and configuration ofeach port.

The Port View permits to set and show the transmission resources (i.e. the Termination Point, TP) referredto the specific Port; it permits to check the detailed alarms presented by each TP of the Port, and theavailable menu permits to configure the port, (many setting options listed in the port menu are commonwith the “Transmission” view).In these views are presented only the TP specific of the port.

The menu differs according the port type (SDH, PDH, HOA, ISA port).

The Port View can be accessed from the Equipment or Transmission Views.

The “Port view” is reached selecting the Equipment option in the View pull down menu then doubleclicking on the presented rack/subrack to present the subrack view, as described in chapter 9 on page 115.Double clicking on the selected board the relevant Board view is available presenting the ports (seechapter 10 on page 133).By double clicking on a board view, the corresponding port view is opened (see Figure 92. ).

The “Port view” is also reached selecting the Transmission option in the View pull down menu.Then the Add TP option of the Transmission menu permits to select and confirm a TP (see the descriptionat para. 14.5 on page 217).

On the transmission view which appears select the TP and on the Transmission menu select theNavigate to a port view option.The HOA port view can be reached from the Port view, selecting a Tp and then Port –> Navigate to HOAport view.The ISA port (ATM, ETH, PR_EA) are not automatically created when the board is inserted in the subrackbut must be created as explained in Chapter 20 on page 427.

From the Port view It is possible to Navigate to Transmission view.

The port types contain the following TP:

• SDH port: Electrical or Optical SPI TTP, RS TTP, MST TTP, prot TTP (MSP TTP), AU4 CTP,Trail Monitor (only with enabled POM)

SONE Tport: Eelctrical or Optical SPI TTP, RST TTP, prot TTP (MSP), AU3 P.

PDH port: PPI TTP, En CTP, VCn TTP

HOA port: VC4 TTP, TUG3, TUG2, TU3, TU12, Trail Monitoring (only with enabled POM)

ISA–ATM port: VC4C TTP, VC4 TTP, VC3 TTP, VC12 TTP, s31 TTP and E1 TTP

ISA–PR_EA port: VC4 TTP, VC3 TTP and VC12 TTP

ISA–Fast ETHERNET port: MAU, PTC, VC3XV, VC12XV, VC4 TTP, VC3 TTP and VC12 TTP

ISA–Gigabit ETHERNET port: MAU, PTC, VC4XV, VC4 TTP, VC3 TTP and VC12 TTP

ISA–ES port: MAU, PTC, VC4XV, VC3XV, VC12XV, VC4 TTP, VC3 TTP and VC12 TTP

NOTE: ISA–PR board does not have any kind of port type.

Page 188: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

140

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LCA

Figure 92. Example of a Port View (example)

On the port view, the messages displayed at the top view in the form of message boxes provide moreinformation concerning the type and the alarms of the port.

On the other hand the messages displayed at the bottom provide information about MSP protection andALS state ( if they are supported ).

A message under the mouse facility provides the name and the port type. A message appears in themessage area in the bottom left corner of the view.

Page 189: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

141

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.2 Port View: elements on the TP

The symbols of the TPs (see Figure 93. ) have the following meaning:

– Alarm Icon AreaThe icon boxes represent alarms. The color of the boxes changes according to the alarm severity.

– TP RoleThe icon boxes represent the function: Adaptation, Termination or Compound Adaptation andTermination.

– Cross-connected stateIf the condition of the resource is cross-connected, an icon with a x appears beneath the box.

– Performance stateIf the condition of the resource is under performance monitoring, an icon with a P appears beneaththe box.

– Loop stateIf the condition of the resource is under loop, an icon with a L appears beneath the box.

– Selected stateAn orange frame around the box identifies the TP selection, so port menu refers to the selected TP.

Alarm icon area

TP identifier

Crossconnected stateSelection indication

G.783 TP Role (Termination)

TP under Performance monitoring

Figure 93. Termination TP box (example)

Figure 94. is another example of TP with different G.783 function role.

Alarm icon area

G.783 Functional block acronym

G.783 TP Role (Adaptation)

Figure 94. G.783 Adaptation TP box.

Page 190: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

142

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.3 Port View Menu

Selecting the “Port” option in the menu bar of Figure 89. on page 136 the complete pull down Port menuis presented (Figure 95. )

The menu differs according the port type (SDH, PDH, HOA and ATM), and is introduced in the following:

– TP configuration: Set parameters for the Signal Label and Path Trace overhead onSynchronous TP’s.See para 14.6 on page 227.

– Port Mode Configuration: This functionality allows to manage the alarms behaviour on LOS according to the setup done at port level.Refer to paragraph 11.4 on page 144.The same functionality can be reached from Configuration –> Port Mode menu.

– TP Threshold Configuration: Set B2 excessive BER and Signal Degraded parameterSee para. 14.7 on page 234.

– TP Frame Mode Configuration: Set parameters for 2Mbit/s G.703/G.704 or ISDN–PRAmanagement

See para 11.8 on page 170.

– Set Retiming: Enable/disable the retiming feature on the outgoing 2 Mbit/s signal. Seeparagraph 11.5 on page 11.5.

– AU4 Concatenation: Only for SDH ports views. See para 11.6 on page 148

– Cross Connection: Manage the connection of the paths. See para.15 on page 253

– Monitoring Operations: Set parameters for POM/SUT/TCTTCM TP’s.See para.14.9 on page 236

– Performance: See and Show Performance Monitoring parameters and data.See Chapter 17 on page 313.

– Loopback: Manage the loopback commands, for commissioning or maintenancepurposes. See para. 14.11 on page 242.

– MSP Manage the Multiplex Section Protection of the NE.See Chapter 13 on page 193.

– Physical Media: Manage the physical TP port setting. Not applicable to HOA port. It is described in the following paragraph.

– Show supporting board: Navigate to the upper board levelIt is described in this chapter, see para.11.9 on page 173

– Navigate to Transmission view: permit to show a complete overview about the signal flow, openingall TP’s.It is described in this chapter, see para.11.10 on page 174

– Navigate to Monitor view: permit to show an overview about the monitoring operation (POM, SUT,TCT/TCM) TP’s. It is described on paragraph 11.11 on page 175.

– Navigate to HOA port view: this option is available only on SDH ports;The HOA pot view display the internal structureof the payload.

Page 191: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

143

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

SDH Port

PDH port

ISA port

Figure 95. Examples of port menu options (SDH, PDH and ATM/GBIT ETHERNET port)

Page 192: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

144

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.4 Port Mode Configuration

”To prevent alarms from being raised and failures being reported during trail provisioning actions, trailtermination functions have the ability to enable and disable fault cause declaration.

This is controlled via their termination point mode or port mode parameter.

The termination point mode can be either ”monitored” (MON) or ”not monitored” (NMON). The state canbe MON if the termination function is part of a trail and provides service and NMON if the terminationfunction is not part of a trail or is part of a trail which is in the process of set–up, breakdown orre–arrangement.

In physical section layers, the termination point mode is called the port mode. It has three modes : MON,AUTO, and NMON (the last is not supported on OMSN).

The AUTO mode is like the NMON mode with one exception: if the LOS defect clears, the port mode isautomatically changed to MON. This allows for alarm–free installation without the burden of using amanagement system to change the monitor mode.

Selecting the “Port Mode Configuration” option in the menu bar of Figure 96. on page 144 the completePort Mode Configuration window is presented (Figure 97. )

Figure 96. Port mode configuration pull–down menu

Page 193: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

145

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 97. Port Mode overview

Port Mode Overview Dialog allows a centralized mechanism for:

– System wide search for Port Mode settings

– Change of Port Mode setting

– Change of Port Mode default.

System wide search capability is offered in order to show port mode value representation for all ports ina NE or in a port subset.

The subset is defined according to the filtering capabilities on Port Type (all ports, SDH port Only, PDHport Only, Ethernet port only, CWDM port only) and to the Port Mode set (Ignore, Mon, Auto).

Change of Port Mode setting can be done on the selected ports in the matrix gadget. Multiple selectionis allowed. The user can choose the new Port Mode ( in the Define Port Mode Values field) and can startthe change on the selected ports (Set Mode).

Change of Port Mode System Default can be done in the related frame. Current system default isvisualized in the combo box current value.

Port Mode Overview dialog is available both at Configuration menu and Port View menu and TransmissionView as well.Using it at Configuration menu the “multi port” working mode is enabled with full support for search andfiltering.Using it in Port View or Transmission View enable the “single port” functionality and the search capabilityis greyed out.

Page 194: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

146

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.5 Set Retiming

The Retiming feature applies to the outgoing 2 Mbit/s and its purpose is to absorb the jitter /wander thatis transferred to the PDH signal when SDH pointer justification occur. The feature is set individually perport.

Select a 2Mbit/s port and zoom in to open the port view.

When the Retiming feature is disable, the color of the state information at the bottom of the window is brownand the label “Retiming State Disable” is written.

Select the Set Retiming–>Enable option from the Port menu (see Figure 98. example)

LCA

Figure 98. Set Retiming enable (before)

As result of this operation the state information color become green and the label “Retiming State Enable”is written (see Figure 99. example)

Page 195: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

147

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LCA

Figure 99. Set Retiming enable (after)

Page 196: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

148

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.6 AU4 Concatenation

Select a STM–N optical interface to configure as AU4 concatenation structure; refer to Table 2.

Table 2. STM–N port and AU4 concatenation supported by each equipment

EQUIPMENT TYPE STM–N interface supported AU–4 concatenation supported

1640FOX STM–4 AU4–4c

1650SMC STM–4 AU4–4c

STM–4 AU4–4c

1660SM STM–16 AU4–16c1660SM

Note: AU4–64c is not supported in current release.

Zoom in to open the board and then the port view menu.

In the following a 1660SM has been choosed like example.

Select the AU4 Concatenation option from the Port menu to open Figure 100. on page 149 (in thisexample a STM–16 view is shown)

The STM16 stream appears divided into different groups: not all AU4s can be chosen as first AU4 but onlyAU4#1, AU4#5, AU4#9, AU4#13 for AU4c. Therefore for concatenated action of four AU4s in one AU4cthese AU4 streams are deleted and substituted by the new AU4c component.

Select the supported concatenation Number =4 to visualize the available group/groups then select thegroup to concatenate and click on the Concatenate push button.

Click on the Cancel key to exit and come back to the previous window.

Page 197: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

149

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 100. AU4 concatenate/deconcatenate commands

The Concatenate button will be enabled and the Deconcatenate button will be disabled when is selecteda non concatenated AU4, viceversa when is selected a concatenated AU4.

Page 198: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

150

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 101. Example of a concatenated AU4 transmission view

The port view represented in Figure 101. shows an STM16 interface with four AU4 concatenated in oneAU4c. The AU4c appears as a single icon that has the same size of the actual AU4 blocks. The AU4cstreams support the Alarm synthesis, Cross–Connection states and Performance Monitoring informationas standard AU4 streams.

To deconcatenate an AU4c select again the “AU4 Concatenation” option in the Port View menu and thenselect the AU4c to deconcatenate (see Figure 102. ). Click on the Deconcatenate push button to applythe command or on Cancel to exit.

Figure 102. Example of a concatenated AU4c

Page 199: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

151

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.7 Physical Media option menu

The Port –> Physical Media options permit to set physical configuration of each TP of the port.

The Physical Media options are also accessible from the Transmission menu.

It opens a menu which differs according to the port type:

• SDH port:

– ALS Management– Show Optical Configuration– Tx Quality Configuration:see para. 18.2.11 on page 375– Single Fiber Configuration– LAPD Configuration: see para.8.6 on page 99.– Ms Configuration

• PDH port:

– Line Length Configuration.– HDSL Configuration. Not operative– NT G703/704 Configuration. Not operative– NT X21 Configuration. Not operative

• ETHERNET port:

– Remote Laser Management. Not operative– ALS Management. Not operative– Ethernet Port Configuration.– Ethernet Mapping Protocol.– ISA port Configuration. Refer to Chapter 20 on page 427.– Control Path Activation.– LCAS Configuration

These options are described in next paragraphs except the previously referenced.

Figure 103. Physical media menu (SDH port example)

Page 200: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

152

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.7.1 Automatic Laser Shutdown Configuration

The aim of this paragraph is to describe the optical port hence the laser sources.

Automatic laser shutdown (ALS) is useful in case of a loss of communication between two NEs due tooptical fiber breakdown. For safety reasons it may be necessary to shutdown the laser to enable the fixingof the communication link.

The automatic laser shutdown function can only be configured from the optical ports of the equipment.

Select the SPI block in the port view and then select the Port pull down menu.

Select the Physical media option and then from the cascading menu the ALS Management option .

The Automatic Laser Shutdown State dialogue box opens ( Figure 104. ).

Figure 104. Automatic Laser Shutdown Management

Page 201: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

153

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The dialogue box enables the ALS Management and the Restart parameters. The following actions areavailable:

a ) Allow Automatic Laser Shutdown.

To allow the automatic laser shutdown functionality, select the ALS Enabled option of the ALSFunction: option button.

b ) Forcing the Laser to start or stop.

When the laser is forced to ON or OFF, it is restarted or stopped and the Automatic Laser Shutdownis disabled, if it was not already so.

1 ) Force laser ON.To carry out a laser forced ON, select the Laser Forced ON option of the ALS Function thenclick on Apply and then or Close push button to close the dialogue.

2 ) Force laser OFF.To carry out a laser forced OFF, select the Laser Forced OFF option of the ALS Function thenclick on Apply and then or Close push button to close the dialogue

c ) Delete : this option deactivates the ALS function, returning to the state shown in Figure 105. on page153.From this window it is only possible to create the ALS function (all the ALS commands are greyed).

Figure 105. Automatic Laser Shutdown Management (after ALS Function delete)

d ) Enabling or Disabling Automatic / Manual Laser Restart.

To enable (disable) an automatic laser restart following an automatic laser shutdown (periodicrestart), select the Enabled (Disabled) option of the ALS Auto Restart. The laser will be ON for2 secs and OFF for 70 secs, in periodic mode. The same procedure is applicable for the ALS Manualrestart : while the ALS auto Restart is disabled,the manual restart permits to perform a laser restartfor a single time period.

Page 202: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

154

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

e ) Wait to restart time

The Wait To Restart Time: field indicating the delay period in seconds, occurring before anautomatic laser restart is launched (following an automatic shutdown). The restart time period forthis equipment is fixed to 70 secs.

f ) ALS Manual restart (not operative in current release)

When the ALS Manual Restart is Enable it is possible to enter two different commands: Manual orTest Restart. The Manual command immediately activates a single laser restart: this commandoverrides the wait to restart time. The Test restart is similar to the manual restart but the laserremains “ON” for a longer time in order to make a measurement of the received optical power.

When all the different parameters have been configured, select the Apply button to confirm the settingand close the dialogue box.Selecting only the Close button allows you to cancel the choices made.The TP list... button opens the clipboard dialog; refer to paragraph 4.3.2.3 on page 59 for details.

Note that the ALS procedure is activated ( if enable ) only when the fiber has been interrupted and theALS state has not to be confused with the laser state.

ALS states (see example of Figure 106. ), displayed by the functional state message area of the opticalport, are:

ALS states:

Inactive = No ALS has been activated (Off) or the laser has been Forced ON/OFF.

In test = The laser restart has been automatically activated .

Active = The ALS has been activated (On).

Undefined = The ALS is not present (not created).

Laser state:

On = all OK or ALS not present (not created).

Off = Laser off (when ALS is created).

Forced on = ALS forced on by operator command.

Forced off = ALS forced off by operator command.

Figure 106. ALS and Laser current state (example)

Page 203: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

155

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 204: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

156

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.7.2 Show Optical Configuration

This command permits to get detailed information on the optical characteristics of the port that isvisualized.

Firstly select an optical board and the SPI block, then click on Show Optical Configuration option fromthe Physical media pull down menu to visualize the parameters of the selected optical port.

Figure 107. shows an example of the parameters of the selected interface.

N.B. This dialogue box can only be read. You cannot write in the entry boxes.

Figure 107. Visualizing a port optical parameters (example)

The laser ports are identified by three major characteristics:

– STM Level: describes the input/output optical interface types:

• STM–1 (1640FOX, 1650SMC, 1660SM)• STM–4 (1640FOX, 1650SMC, 1660SM)• STM–16 ( only on1660SM)• STM–64 ( only on1660SM Rel. 5.1 )

– The wavelength of the laser source: the units are nanometers (nm = 10–9 m).

– The use of the port: describes whether the laser port is used for intraoffice transmissions on longdistances (Long Haul � 40 km) or for infraoffice transmissions on short distances (Short Haul �15 km).

The Colored Interface Parameters display the Channel used and the Grid spacing.To close the dialogue box click on the Cancel push button.

Page 205: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

157

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.7.3 Single Fiber Configuration

The single fiber configuration can be realized with passive optical couplers (see Figure 108. )The optical coupler must not loop the Tx signal onto the local Rx .For this purpose and in general to avoid a low Tx/Rx decoupling also when the optical line is interrupted,an identification label has been assigned to the local Tx side ; the Rx part in the remote receive side checksthe congruency between the received and the expected labels. If a signal label mismatch is recognizedon the received section, an alarm (AIS and RDI) will be generated. Example of Figure 108. shows thatis accepted the label “1” from Tx1 to Rx2 while is accepted label “2” from Tx2 to Rx1.

Tx1 Tx2

Tx1 Label : 1 Tx2 Label : 2

Rx1 Rx2

OPTICALPASSIVE

COUPLER

OPTICALPASSIVE

COUPLER

Rx1: accepted label=2 Rx2: accepted label=1

Single bidir

Figure 108. Bidirectional Transmission on a single fiber

Page 206: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

158

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Select the Physical media option and then from the cascading menu the SDH Single FiberConfiguration option .

Figure 109. opens. The following fields have to be considered:

– Allow Single Fiber: select the transmit mode on the single fiber (enable or disable).

– Transmitted Section:

• Transmitted Media Byte – assigned label to Tx (0–14).

• Transmitted Media Type – overhead byte used for the communication:

– Media Dependent byte of Regeneration Sectionor

– S1 byte of Multiplex Section (the part not used for the SSM)

– Received Section:

• Received label

• Expected label (0–14).

Figure 109. Single Fiber Configuration View

Page 207: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

159

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.7.4 Ms Configuration

The Ms Configuration menu allows the SS bit provisioning for Multiplex Section Object (MSTTP) inSONET/SDH network interworking.

Select the MSP TP.

Click on Ms Configuration menu option of the Port–> Physical Media menu. Figure 110. opens.

This dialog allows to select between SDH or SONET networks. After the selection click on Apply and thenon Close to close the dialog.

Ms Forced AIS is not supported in the current release.

Figure 110. Ms Configuration

Page 208: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

160

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.7.5 Line Length Configuration

This option is not effective on 1640FOX because this function is implemented by amanual switch located on the “1x45Mb/s” module; refer to the 1640FOX technicalhandbook to set it.

To manage the Line Length configuration click on Line Length Configuration menu option of thePhysical Media menu. Figure 111. opens.

This dialog allows to configure the line length for a PDH PPI TP of a 45 Mbit/s port.

The OK button validate the configuration and close the dialog box.

The Cancel button removes the dialog

Figure 111. PDH Line Length Configuration View

Page 209: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

161

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.7.6 Ethernet Port Configuration

To set the Fast Ethernet (10/100 Mbit/s) port parameters, select the Ethernet Port Configuration optionof the Port –> Physical Media menu as shown in Figure 112.

LCA

Figure 112. Ethernet Port Configuration options (fast ethernet example)

Subsequently Figure 113. on page 161 will be opened.

Figure 113. Ethernet Port Configuration menu

Page 210: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

162

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

For the Fast Ethernet (10/100 Mbit/s) port it is possible to choose between two “Configuration Type”:

[1] “Auto Negotiation” : allows to configure the “Rate” to be negotiated (10 or 100 Mb/s).The “Directionality” (Full Duplex) and the “Flow Control” (Activated) are always enable and can’tbe changed.

[2] “Manual”: allows to force the “Rate “ at 10 or 100 Mb/s .The “Directionality” is always Full Duplex.

Moreover It is possible to Restart the “Auto Negotiation” by depressing the relevant button; if parametershas been changed before pressing the Restart button , a question dialog is displayed (see Figure 114. on page 162) to advice that the user has changed data but not applied them.

Figure 114. Information dialog

In read only mode there are indication if the Auto negotiation on remote side is activated (Remote AutoNegotiation) and what parameters are allowed on remote (Remote Allowed Parameters).

In both cases is possible to check the the “Auto negotiation Current State” with the possible massage:

– completed OK– completed KO– configuring– deactivated– parallel Defect Fail– other

At the bottom of the port view are displayed the following indications (refer to Figure 112. on page 161and Figure 115. on page 163):

– the “Interface Type”:

• S1000 Base SX (only for Gigabit Ethernet board)• S1000 Base LX (only for Gigabit Ethernet board)• S1000CX (only for Gigabit Ethernet board)• S100BaseTX• S100BaseFX• Unknown• S10BaseT

– the “Bit Rate” (only for fast ethernet board):

• 10 Mb/s• 100 Mb/s

Page 211: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

163

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LCA

Figure 115. Gigabit Ethernet port view (example)

Page 212: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

164

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.7.7 Ethernet Mapping Protocol

Select a VC TP.

Click on PortEthernet Mapping Protocol option of the Port–> Physical Media menu. Figure 116. opens.

Figure 116. Ethernet Mapping Protocol (EXAMPLE)

This dialog aims to show the actual Ethernet mapping protocol used and allowing the user to change it.In Figure 14 is depicted an example of this new view.

The options available are the following:

– ISA–FAST ETHERNET boards:

• GFP null extension Header with FCS

• GFP null extension Header without FCS

• GFP for Packed concatenation extended

– ISA–GIGABIT ETHERNET boards:

• GFP null extension Header with FCS

• GFP null extension Header without FCS

– ISA–ES and ISA–PR–EA boards:

• GFP null extension Header without FCS

• HDLC

Page 213: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

165

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.7.8 Control Path Activation

This dialog allows to modify the state of the Ethernet port virtualTPs, created as explained in Chapter20 on page 427.

Select a TP in the Ethernet port view window.

Click on Control Path Activation option of the Port–> Physical Media menu.A new window will be opened (Figure 117. and Figure 118. are examples); a similar window is displaywhen a new concatenated VCX is created in the “ISA port configuration” window (refer to paragraph 20.2.3on page 432).

This dialog aims to show the activation state of the virtualTPs present in the Ethernet Port View and tochange the number of virtual TPs active.

Two modality are foreseen to activateTPs:

[1] Individual path (refer to Figure 117. ): the Active state is reached by selecting the individual row withthe mouse and click on the Change Status button.

[2] Path Range (refer to Figure 118. ):the Active state is reached by choosing the number of “TPs to beactive” and click on the Apply button.On the contrary to change in Idle the Active state of a TP decrease the “TPs to be active” field andthen and click on the Apply button.

To switch bwtween the two modality click on the relevant button in the Activation Mode field. In this fieldit is also displayed the Actual Selected Mode.

Figure 117. Control Path Activation:Individual Path mode

Page 214: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

166

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 118. Control Path Activation:Range Path mode

Click on the Refresh button to uptade the changes.

Click on Close button to close the Control Path Activation window.

Page 215: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

167

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.7.9 LCAS Configuration

Link Capacity Adjustment Scheme (LCAS) is used to increase or decrease the capacity of a container thatis transported in a SDH network using Virtual Concatenation. In addition, the scheme automaticallydecrease the capacity if a member experinces a failure in the network, and increase the capacity whenthe network fault is repaired. The scheme is applicable to every member of the Virtual ConcatenationGroup (VCG).

Select a VCnXv TP an than the LCAS Configuration option from the Port –> Physical Media menu (referto Figure 119. I); Figure 120. will be opened.

Figure 119. LCAS configuation pull–down menu

Figure 120. can be reached also from ISA board Configuration window (refer to paragraph 20.2 on page428).

Figure 120. LCAS Configuration

Page 216: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

168

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

In the LCAS Configuration window it is possible to Enable / Disable the LCAS scheme protocol selectingthe relevant button.

The Monitoring... button opens the LCAS monitoring window dysplayed in Figure 121.

Other parameters can be set:

– RS acknowledge timeout; it is the timeout value (in milliseconds) LCAS protocol waits for there–sequence acknowledge message

The button Apply will se the attribute Max differential delay and RS acknowledge timeout if the LCASprotocol is enable.

Figure 121. LCAS Monitoring

The LCAS Monitoring window is divided in two section, the first reports information concerning the VirtualConcatenation Group Monitoring Parameters, the second reports the Channels Monitoring Parameters.

Virtual Concatenation Group Monitoring Parameters fields description:

– Active Channel Number: display the number of Vcs active on Source and Sink read on Node A.

– Acknowledge Bit (Re–Sequence Acknowledge) Source and Sink: when a renumbering of thesequence numbers of the members sending in CTRL field NORM, DNU, EOS, or when a change ofthe number of these members is detected at the Sk, a notification to the So per VCG has to beperformed by toggling (i.e. change from ’0’ to ’1’ or from ’1’ to ’0’ ) the RS–Ack bit.

– MST Channel Ref.: indicates wich channel of the VCG is the reference one for MST information;MST information report the member status from Sk to So with two states: OK or FAIL (1 status bitper member).OK = 0, FAIL = 1.

– VCG Master: indicates wich channel is the reference channel for the Differential Delay calculation.

Page 217: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

169

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Channels Monitoring Parameters fields description:

– The first column contains the channel identifier inside the VCG (called Sequence Number) .

– Tx CTRL Packet: Message sent (ADD, DNU, IDLE, NORM, EOS, FIXED), relative to a traffic flowfrom Node A to Node B; it provides the status of the individual member of the group as reported inthe following:

• Fixed: this is an indication that this end uses Fixed bandwidth (non–LCAS mode)• Add: this member is about to be Added to the group• Norm: Normal transmission• Eos: End of Sequence indication and Normal transmission• Idle: this member is not part of the group or about to be removed• Dnu: Do Not Use (the payload) the Sk side reported FAIL status• Unknow

– Rx Channel State: MST indication (OK/FAIL) relative to a traffic flow Node B to Node A;

– Rx CTRL Packet: Message received (ADD, DNU, IDLE, NORM, EOS, FIXED), relative to a trafficflow from Node B to Node A; it provides the status of the individual member of the group as reportedin the following:

• Fixed: this is an indication that this end uses Fixed bandwidth (non–LCAS mode)• Add: this member is about to be Added to the group• Norm: Normal transmission• Eos: End of Sequence indication and Normal transmission• Idle: this member is not part of the group or about to be removed• Dnu: Do Not Use (the payload) the Sk side reported FAIL status• Unknow

– Tx Channel State: MST indication (OK/FAIL) relative to a traffic flow Node A to Node B;

– Differential Delay: it is calculated respect to the Virtual Concatenation group Master channel,relative to a traffic from Node B to Node A .

– TxVC: contains the sequence number assigned to a specific member from Node A to Node B. Eachmember of the same VCG is assigned a unique sequence number, starting at 0.

– RxVC:contains the sequence number assigned to a specific member from Node B to Node A. Eachmember of the same VCG is assigned a unique sequence number, starting at 0.

The Refresh button refreshes the values displayed.

Page 218: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

170

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.8 TP Frame Mode Configuration

This menu item enables the configuration of the most important transmission parameters concerning thePrimary Rate Access (PRA) and G.703/G.704 frame management.

PRA management

The PRA functionality performs termination bi–directional function for Time Slot 0 on framed with CRC–42 Mbit/s signal.In detail, it extracts in sink direction and writes in source direction particular bits (E, Sa5, Sa6 and A) ofthe Time Slot 0.Moreover, it generates substitution frames in case of detection of LOS on the signal coming from aTerminal Equipment.The PRA functionality has been extended in order to manage proprietary handling of the bits of Time Slot0 (Framed with leased line PRA option) in terms of state, defect detection and consequent actions.

G.703/G.704 management

This functionality allows to activate the adaptation function to process a framed (G.704 interface) or notframed (G.703 interface) 2Mbit/s signal.

This TP Frame Mode Configuration option is available for:

– P12–CTP

Select the desired P12–CTP and then the Port –>TP Frame Mode Configuration option.

TP Frame Mode Configuration can also be accessed from the “Transmission” and “Synchronization”view menu.

The following dialog appears:

Figure 122. TP Frame Mode Configuration

Page 219: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

171

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The windows contains the following graphical objects:

– ”Framed Signal Mode” that allows to configure the attribute framed Signal Mode; the user canchoose one of the following value:

• ”Not Framed” (G.703 interface): the PRA function cannot be activated ;

• “Framed without PRA” (G.704): the behavior according to ETS 300–233 is applied in thehandling of bits of Time Slot 0 in terms of state, defect detection and consequent action;

• ”Framed with PRA” : PRA function are activated

• ”Framed with leased line PRA” : a proprietary leased line behavior is applied.

In PRA applications, the following features are managed:

• a configurable parameter in order to define the operation modes of the CRC procedure;

• the configuration of the “consequent action” on the transmitted 2M/s signal in case of configuredretiming functionality and loss of synchronization (when the CRU is in HoldOver orFreeRunning mode).

• the configuration of the “consequent action” concerning the AIS insertion for boardP63E1N–M4 in leased Line mode.

– “CRC4 Status“ that defines the monitoring capabilities applied to the signal with a CRC multiframe:

• “Operation”: allows to configure the CRC–4 processing modalities; the possible value are:

• “Disabled” that disables the CRC–4• “Forced” that configures CRC–4 with consequent actions• “Automatic” that triggers the CRC–4 algorithm in order to allow

interworking of pieces of equipment with and without a CRC4 capability.

• “Monitoring Enabling”: enable or disable the CRC–4 error counting

• ”Remote Indication”: read–only field that indicates if status of CRC–4 error countingfunctionality of far–end NE is enabled or disabled.

– Two “Consequent Action” are forseen:

• “Loss of Synch Consequent Action” allows to perform the consequent action on thetransmitted 2M/s signal with retiming when the CRU is in Holdover or Freerunning mode; theconsequent action is performed only if PRA or leased line application ha been configured onthe associated P12–CTP.The possible values of the Loss of Sync Consequent Action are:

– ”Timing Plesiochronous” that causes a timing as 2 Mb/s incomin signal

– ”Insert AIS” that causes AIS insertion

Page 220: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

172

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

• “Far–End defect Consequent Action” allows the AIS insertion towards 2Mb/s PDH asconsequent action upon the detection of the far–end defect on the SDH side (by a specialpattern carried in Sa4–bits); it works only in leased line application;

The values attribute are:

– ”SubstitutionFrame” that means ”no action”

– ”AIS” that causes AIS insertion

– “Frame Status” is a read–only field that reports an indication of the received signal:

• ”no indication”

• “the 2Mb/s signal is multi–frame”

Press Ok to apply the parameters or Cancel to close the dialog.

Page 221: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

173

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.9 Show Supporting Board

Select a TP.

Click on Show Supporting Board menu option of the Port menu to navigate to the board that supportsthe selected port view.

Figure 123. (example) opens.

LCA

Figure 123. Board View Example.

Page 222: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

174

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.10 Navigate to Transmission View

Select a TP.

Click on Navigate to Transmission View menu option of the Port menu to navigate to the correspondingTransmission View that is related to the selected TP.

Navigation to the Transmission view permits to show a complete overview about the signal flow as for theexample of the following figure..

LCA

Figure 124. After “Navigate to Transmission view” selection (example)

Page 223: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

175

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.11 Navigate to Monitoring View

Select a TP where are configurated some Monitoring Operations (POM, SUT, TC).

Click on Navigate to Monitoring View menu option of the Port menu to navigate to the correspondingMonitoring View that is related to the selected TP.

Navigation to the Monitoring view permits to show a complete overview about the Monitoring Operations(POM, SUT, TC) as for the example of the following figure.

In Figure 125. on page 175 is shown an example of Monitoring View of a TP with POM and TCM bothbefore and after matrix.

Figure 125. View of Monitoring Operations (example)

Page 224: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

176

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

11.11.1 Navigate to HOA Port View

After having selected a Tp (for example AU–4), click on Port –> Navigate to HOA Port View option.

The HOA port displays the internal structure of the payload, as for the following figure:

Figure 126. Navigate to HOA Port

Page 225: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

177

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

12 EQUIPMENT PROTECTION MANAGEMENT (EPS)

This function is not applicable to 1640FOX ; the descriptions reported in this chapter isintended only for 1650SMC and 1660SM.

12.1 Introduction

It is unthinkable to launch a telecommunications system, handling millions of communications, without thepossibility of replacing equipment in a real time way, consequent to equipment failure. Everything mustbe done so that the communications can continue smoothly and so that the equipment failure remainstransparent to the users. Protection management deals with this aspect of the EML–USM.

The protection is performed by switching the board supporting the protected service when this board failsto a protecting board capable of supporting the same service. This protection is realized according to aprotection scheme.

An equipment protection scheme is composed of the following parameters which can be configured:

• Group type: 1+1 or 1+nthe group type specifies if one or more unreliable resources for protection can be assigned toone or more reliables resources. 1+1 group type means that a working element is protected byone protecting unit. 1+n group type means that n working elements are protected by only oneprotecting unit.

• Protection priority:A priority can be assigned to protected units in 1+n protection schemes. This priority can be be1, 2, ... or n, 1 being the highest priority.

• Configuration type: revertive or non revertiveIn revertive mode, a protected service will be switched back to its protected element when it hasrecovered from its failure.In non revertive mode, the switch to the protecting element is maintained even after a recoveryfrom failure.

• Protection wait to restore time:Used when revertive mode is active, the protection wait to restore time prevents severalprotection switches due to an intermittent failure. A protected element must be fault free duringthis fixed period of time before a protected service is switched back to it.

Board duplication remains the easiest way to ensure equipment protection in a system.The actions that can be undertaken are of the following type:

– Consult and modify an Equipment Protection Scheme (EPS),– Force Switch EPS,

In Board view, the board whose contents is represented is considered as implicitly selected.

EPS protection states are displayed by the functional state message area of the boards involved in anequipment protection scheme.

Page 226: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

178

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

12.2 Management: consulting and modifying EPS

In order to consult EPS, perform the following operations:

The “Port view” is reached selecting the Equipment option in the View pull down menu to present thesubrack view, as described at chapter 9.1 on page 115.

– Select the Equipment option in the View pull down menu.– Select the EPS pull down menu. Then select the Management... option as show in the following

figure.

Figure 127. Consulting EPS

The following dialogue box is opened.

r01sr1/board#40

r01sr1/board#23

r01sr1/board#32

r01sr1/board#27

Figure 128. EPS Management dialogue box (example)

The EPS Management dialogue box shows the current NE protection schemes in the left side. Thelist gives for each protecting board the protected board(s).

The available protection schemes are coherent with the NE type and release.

The right side of the dialogue box allows to modify the EPS configuration.

Page 227: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

179

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The current release of this NEs fix the following protection:

– 1660SM EQUIPMENT:

• N+1 (with N ≤ 6)“P63E1 or P63E1N–M4” protection:

– board of slot MAIN (protected): P63E1 or P63E1N–M4, slots 24–27–30–33–36–39– board of slot SPARE (protecting): P63E1 or P63E1N–M4, slot 32

• N+1 (with N ≤ 15) “P3E3/T3” protection:

– board of slot MAIN (protected): P3E3/T3, from slot 25 to 39– board of slot SPARE (protecting): P3E3/T3, from slot 24 to 38

• N+1 (with N ≤ 15) “P4ES1N” protection:

– board of slot MAIN (protected): P4ES1N, from slot 25 to 39– board of slot SPARE (protecting): P4ES1N, from slot 24 to 38

• N+1 (with N ≤ 15) “P16S1–4E” (ELECTRICAL ONLY) protection:

– board of slot MAIN (protected): P16S1–4E, from slot 25 to 39– board of slot SPARE (protecting): P16S1–4E, from slot 24 to 38

N.B. For P3E3/T3 P4ES1N and P16S1–4E more than one protection group N+1 revertivecan be created, depending on the equipment configuration.The spare board position can be assigned in a flexible way .The only constraint arethe following:

• the access card corresponding to the protecting board must be an HPROT card• the HPROT card has to be plugged at the left side of the access card group• the main/spare boards have to be adjacent.• the protecting board has to be plugged at the left side of the protected group of boards• the protecting/protected group of ports have to be of the same type

• 1+1 “ATM MATRIX 4x4” protection:The ATM MATRIX board can be protected in 1+1 equipment protection scheme.In this configuration the ATM MATRIX and all indirect interfaces connected to it are protectedagainst ATM module failure. This does not apply to the local STM–1 interface so the traffic onit is lost.A maximum of two protection group 1+1 not revertive can be created.The spare card position can be assigned in a flexible way; no restriction for position of main andspare ATM MATRIX are present.

• 1+1 “ATM MATRIX 8x8” protection:The ATM MATRIX board can be protected in 1+1 equipment protection scheme.In this configuration the ATM MATRIX and all indirect interfaces connected to it are protectedagainst ATM module failure.A maximum of two protection group 1+1 not revertive can be created.The spare card position can be assigned in a flexible way; no restriction for position of main andspare ATM MATRIX are present.

• 1+1 ISA PR_EA (PREA4ETH, PREA1GBE)” protection:The ISA PR_EA boards can be protected in 1+1 equipment protection scheme.In this configuration the ISA PR_EA and all indirect interfaces connected to it are protectedagainst module failure. This does not apply to the local interface so the traffic on it is lost.A maximum of two protection group 1+1 not revertive can be created.

Page 228: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

180

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The spare card position can be assigned in a flexible way; no restriction for position of main andspare ISA PR_EA are present.

• 1+1 ISA ES–16” protectionThe ISA ES–16 boards can be protected in 1+1 equipment protection scheme.In this configuration the ISA ES–16 and all indirect interfaces connected to it are protectedagainst module failure. This does not apply to the local interface so the traffic on it is lost.A maximum of two protection group 1+1 not revertive can be created.The spare card position can be assigned in a flexible way; no restriction for position of main andspare ISA ES–16 are present.

• 1+1 “MATRIX” protection

– board of slot 23, MATRIX main (protected)– board of slot 40, MATRIX spare (protecting)

N.B. for each type of failure on the MATRIX main board ( CRU, Shelf Controller) a switch isperformed to the spare boards.

The MATRIX protection is automatically presented in the left side of the dialog box whenthe SPARE MATRIX is created in the Set option of the Equipment menu. It is not createdwith the EPS menu described in this chapter.

– 1650SMC EQUIPMENT:

• N+1 (with N=1) P63E1 or P63E1N–M4 protection

– board of slot 6, 63 x 2 Mbit/s (P63E1 or P63E1N–M4) main (protected)– board of slot 7, 63 x 2 Mbit/s (P63E1 or P63E1N–M4) spare (protecting)

• N+1 (with N ≤ 2) “P3E3/T3” protection

– board of slot MAIN (protected): P3E3/T3, from slot 7 to 8– board of slot SPARE (protecting): P3E3/T3, from slot 6 to 7

• N+1 (with N ≤ 2) “P4ES1N” protection

– board of slot MAIN (protected): P4ES1N, from slot 7 to 8– board of slot SPARE (protecting): P4ES1N, from slot 6 to 7

N.B. For P3E3/T3 and P4ES1N only one protection group N+1 revertive can be created,depending on the equipment configuration.The spare board position can be assigned in a flexible way .The only constraint are thefollowing:

• the access card corresponding to the protecting board must be an HPROT card• the HPROT card has to be plugged at the left side of the access card group• the main/spare boards have to be adjacent.• the protecting board has to be plugged at the left side of the protected group of boards• the protecting/protected group of ports have to be of the same type

• 1+1 “ATM MATRIX 4x4” protectionThe ATM MATRIX board can be protected in 1+1 equipment protection scheme.In this configuration the ATM MATRIX and all indirect interfaces connected to it are protectedagainst ATM module failure. This does not apply to the local STM–1 interface so the traffic onit is lost.A maximum of one protection group 1+1 not revertive can be created.

Page 229: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

181

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The spare card position can be assigned in a flexible way; no restriction for position of main andspare ATM MATRIX are present.

• 1+1 ISA PR_EA (PREA4ETH, PREA1GBE)” protectionThe ISA PR_EA boards can be protected in 1+1 equipment protection scheme.In this configuration the ISA PR_EA and all indirect interfaces connected to it are protectedagainst module failure. This does not apply to the local interface so the traffic on it is lost.A maximum of one protection group 1+1 not revertive can be created.The spare card position can be assigned in a flexible way; no restriction for position of main andspare ISA PR_EA are present.

• 1+1 ISA ES–16” protectionThe ISA ES–16 boards can be protected in 1+1 equipment protection scheme.In this configuration the ISA ES–16 and all indirect interfaces connected to it are protectedagainst module failure. This does not apply to the local interface so the traffic on it is lost.A maximum of oneOne protection group 1+1 not revertive can be created.The spare card position can be assigned in a flexible way; no restriction for position of main andspare ISA ES–16 are present.

• 1+1 COMPACT ADM (SYNTH1N or/and SYNTH4) protection

N.B. In the following will be explained some rules for EPS schema configuration usingSYNTH1N board; the same rules can be applied to SYNTH4 board.Mixed configuration are also allowed (i.e. EPS schema composed by SYNTH1N andSYNTH4).

– board of slot 9, COMPACT ADM–1 (SYNTH1N) main (protected)– board of slot 10, COMPACT ADM–1 (SYNTH1N) spare (protecting)

N.B. for each type of failure on the COMPACT ADM main board (matrix, CRU, ShelfController) a switch is performed to the spare boards. The optical/electrical port andthe Equipment Controller function on the COMPACT ADM board are not EPSprotected.

The SYNTH1N/SYNTH4 protection is automatically presented in the left side ofthe dialog box when the SPARE SYNTH1N/SYNTH4 is created in the Set optionof the Equipment menu. It is not created with the EPS menu described in thischapter.

This right side of Figure 128. is divided into two parts.The upper part provides a message field with the name of the Protecting board and a choose button todisplay the list of boards available.The lower part provides a list to display the Protected boards currently in the displayed scheme.A choose button is provided to display the list of boards which could be added as protected.A delete button enables user to remove a protected board from a scheme.

a ) Scheme displaying

To display a specific scheme, user selects an item on the left list.This operation fills the protecting element text field and the protected list with the board user name. If userclicks where there is no item displayed, the right part is displayed empty.The Cancel push button closes the dialog box.

b ) Scheme creation

Page 230: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

182

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

To create a new protection scheme,don’t click on item in the left list.In this way the right part is displayed empty and the Choose Protecting button is sensitive.Press this button to displays a window to choose a board in the “Board Selection” list (see Figure 129. onpage 183). The board are listed opening the NE>rack>subrack levels.

After that operation, Choose Protecting button becomes insensitive and Choose Protected becomessensitive (see Figure 130. on page 183)The user can add, always using the same “Board Selection” list dialogue box presented, as manyprotected boards as wanted (max.15 in 1660SM, max. 2 in 1650SMC).

When the right part of window is correctly filled, the OK button close the dialog box and create the scheme(the new list is update re–opening the EPS Management dialogue box).The Cancel push button cancels the creation and closes the dialog box.

c ) Scheme deletion

To delete an existing protection scheme, the user selects a scheme in the left list. Using the Delete button,user could delete the scheme.

Page 231: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

183

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

d ) Scheme modification

To modify an existing protection scheme by adding or removing protection units, the user selects a schemein the left list. Using Choose button for protected elements, user could add protected boards.By selecting a protected board and using the Delete Protected button, user could remove protectedelements from scheme. When the right part of window is correctly filled, the OK button close the dialogbox and modify the scheme.The Cancel push button cancels the creation and closes the dialog box.

Figure 129. EPS: board selection (example)

Figure 130. EPS: choose protected (example)

Page 232: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

184

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The EPS functional state of a board selected in the board view is displayed at the bottom of the view asshown in the following figures.

Protection role Protection status Switch Type

Figure 131. EPS functional state from protected active board view

Figure 132. EPS functional state from protecting active board view

Page 233: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

185

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

12.3 Configuration: revertive and WTR for EPS

This functionality configure Revertive and Wait Time to Restore in a protection scheme.

In order to configure, perform the following operations:

– Select a transmission board in the Equipment view.

– Select the EPS pull down menu. Then select the Configure option as show in the following figure.

Figure 133. Configure EPS

The following dialogue box is opened.

Figure 134. EPS Management dialogue box (example)

Page 234: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

186

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The dialog box provides configuration for elements such as :

– the name of the protecting element as a label– the Equipment Type (board) of the protecting element as a label– a list displaying the protected elements owned by the scheme– the Revertive Mode flag as an option menu. The available values are revertive and non revertive– the wait time to restore time value (steps of 30 seconds, from 60 to 600). Only for N+1 EPS.

Notes: in the current release the Wait Time to Restore is fixed to 5 minutes.

The following protection mode are supported :

– 1660SM EQUIPMENT:

• 1+1 ATM MATRIX 4x4 is Not Revertive only

• 1+1 ATM MATRIX 8x8 is Not Revertive only

• 1+1 PR_EA is Not Revertive only

• 1+1 ES–16 is Not Revertive only

• 1+1 MATRIX is Not Revertive only

• N+1 63 x 2 Mbit/s (P63E1 or P63E1N–M4) protection is Revertive

• N+1 3x34/45 Mbit/s (P3E3/T3) protection is Revertive

• N+1 4x STM–1 ELECTRICAL port (P4ES1N) protection is Revertive

• N+1 16x STM–1 ELECTRICAL port (P16S1–4E) protection is Revertive

– 1650SMC EQUIPMENT:

• 1+1 ATM MATRIX 4x4 is Not Revertive only

• 1+1 PR_EA is Not Revertive only

• 1+1 ES–16 is Not Revertive only

• 1+1 COMPACT ADM (SYNTH1,SYNTH1N or SYNTH4) is Not Revertive only

• N+1 63 x 2 Mbit/s ( P63E1 or P63E1N–M4) protection is Revertive

• N+1 3 x 34/45 Mbit/s (P3E3/T3) protection is Revertive

• N+1 4 x STM–1 Electrical (P4ES1N) protection is Revertive

When the configuration of the equipment protection scheme is completed confirm closing the dialog boxby clicking on the OK push button. The Cancel push button cancels the configuration and closes the dialogbox.

Page 235: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

187

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

12.4 Switching EPS

This functionality enables to force a protecting board to work even if there is not failure.

The forced switch will fail if the other board is already forced switched or if the protecting board has a failurecondition.

In order to switch an EPS, perform the following operations:

– Select a transmission board in the Equipment view.

– Select the EPS pull down menu. Then select the Switch option as show in the following figure.

Figure 135. Switching EPS

The following dialogue box is opened.

Figure 136. EPS Switch dialogue box (example)

This dialogue box displays in its left part the EPS of the selected board.

From this dialogue box the operator can configure, in the current release, only the Lockout options, byclicking on the relevant radio button.

The Manual to command perform the “manual” switch, active only if the other board is not alarmed.

Clicking on the OK push button will initiate the switch and close the dialogue box. The Cancel push buttoncancels the operation and closes the dialogue box.

Page 236: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

188

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

12.5 EPS Overview

EPS Overview allows to display as well as search for EPS states.

Selecting the EPS Overview option from the Configuration pull down menu Figure 137. opens

Figure 137. EPS overview

To Search the EPS groups two different ways of filtering are supported; a filtering for all protection unitslocated on a dedicated Board Type as well as a filtering for protection units carrying a specific Status.

The search criteria can be chosen with the help of a combo box:

– Board Type: allows to filter for the EPS protected boards (example Ignore, SYNTH1N, MATRIXN,P3E3/T3, etc. )

– Status: allows to filter for all possible EPS protection states;the following filters values should beoffered (examples):

• Ignore• Normal• DNR• Auto–Fail• Auto–WTR• Manual• Force• Lockout

After the filter selection click on Search button to start; the field below the Search button will be updated(see Figure 138. )

Page 237: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

189

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 138. EPS overview after Search (Example)

Page 238: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

190

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Each protection unit is presented with the following information:

– Protection Group (example protection GroupId, 40)

– Board Id (example r01sr1/board#40 )

– Board Role:

• Ped (Protected)• Ping (Protecting)

– B Status (board status):

• A (Active)• S (StandBy)• F (Faulty)

– Protection Status: defines the current state of the protection unit as follow

• Normal• DNR (Do Not Revert)• Auto–Fail (Autoswitch Equipment Fail)• Auto–WTR (Autoswitch Wait Time to Restore)• Manual (Manual switch)• Force (Force switch)• Lockout

The colors used for each row have the following meaning:

– Green (OK): for protected protection units active

– Red (Critical): for protected protection units in fail condition, protection unit in lockout or activeon autoswitch or commands

– Orange (Major): for protected units in standby after a command and protecting protection unitin standby for autoswitch or commands

– Cyan (Indicative): for protecting protection unit active and no fail condition present in the schema(Do Not Revert State)

At the bottom of the EPS Overview windows are available five button that allows to navigate through theEPS management views and subrack view, board view.In this way the operator has a quick link towards the views showing the correlation between the alarmsand the protection states.

N.B. Before to click on one of the five buttons select a row

Page 239: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

191

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The buttons available are:

– Open Subrack View: opens the Subrack view showing the protection states with icons on theboards (see example of Figure 139. )

The possible protection states and the relevant symbols are explained inthe following:

Symbol EPS protection status

No RequestDo not Revert

Lockout

Auto Switch (WTR, Fail)ManualForced

– Open Board View: opens the board view showing the alarm and the board administrative states (see example of Figure 140. )

– Open Commands: opens the EPS Switch dialog box. See 12.4 on page 187 and the relevant description.

– EPS Management: opens the EPS Management dialog box. See Figure 128. on page 178and the relevant description.

– EPS Parameters: opens the EPS Configuration dialog box. See 12.3 on page 185and the relevant description.

Click on Close button to exit from the EPS Overview window

Page 240: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

192

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LCA

Figure 139. Subrack view after “Open Subrack View” command (example)

LCA

Figure 140. Board view after “Open Board View” command (example)

Page 241: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

193

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

13 MULTIPLEX SECTION PROTECTION MANAGEMENT (MSP)

13.1 Architecture types

The Multiplex Section Protection (MSP, formerly called APS: Automatic Switching Protection) is theconnection between two NEs protected by a cable and port duplication. At the source the signal isduplicated and sent to the sink via two independent cables. When occurs a multiplex section failure, thesystem switches to the other cable and port.

The MS Linear Trail Protection can be applied to any NE where it is possible to configure a linear APS(single ended/dual ended) line protection. For this NE is applicable the APS 1+1 Proprietary, the APS1+1 Standard and the APS 1 :1 Standard dual ended.

The APS 1 +1 (not revertive) feature permits a 1+1 protection in a linear link, where a path signal isprotected by another dedicated path carrying the same signal. The protection can be set both in single(unidirectional) and in dual (bidirectional) ended mode.In single ended mode (unidirectional) the protection is accomplished by switching only the signal affectedby the failure.In dual ended mode (bidirectional) the protection is accomplished by switching both the affected and theunaffected signals .

“Dual ended mode” (bidirectIonal) protection is not supported by 1640FOX and 1650SMC

Architecture 1+1 or N+1 Standard (the last is only available for 1660SM)Described in ITU–T Rec. G783/G841. The refence switching criteria are SF and SD. It provides ak1/k2 communication protocol thus this protection can be single or dual ended.

Architecture 1+1 Proprietary (not used )The refence switching criteria are SF and SD. No k1/k2 communication protocol is provided thusthis protection can be only single ended.

Architecture 1+1 Optimized (not used )

Architecture 1 : 1 Standard (not used )Described in ITU–T Rec. G783/G841 as architecture 1 : n ( with n=1 ). The refence switching criteriaare SF and SD. It provides revertive mode managed by k1/k2 protocol and thus this protection canbe single or dual ended. The spare interface can be used to transport “low priority traffic” .

The WTR time is used with revertive mode.

Signal Degrade (SD) software setting enables the MSP protection mechanisms when a SD is recognizedon the working port. The SD threshold reference value depend on the NE selected threshold on the MStermination point. This threshold value is configured as explained in the para.14.7 on page 234.

Page 242: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

194

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

13.2 MSP Options Introduction

All the MSP options are available starting from the Port View following the step explained below:

– Select Equipment from the Views menu

– Double click on the SDH optical board to configure to open the port icon

– Double click on the port icon to open the port view

– Select the MSP block in the port view and then choose the MSP options by clicking on Port –> MSPmenu; the possible choice are:

• MSP Create see para 13.3 on page 195.

• MSP Management see para 13.4 on page 199.

• MSP Commands see para 13.7 on page 204.

• MSP Delete see para 13.5 on page 201.

MSP Create, MSP Management, MSP Commands and MSP Delete can also be accessed from theTransmission –> MSP menu.

Page 243: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

195

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

13.3 MSP Create

Select the MSP Create option from the Port –> MSP menu ( see Figure 141. on page 195) to openthe MSP Schema Creation (see Figure 142. on page 195).

Figure 141. MSP Create Option

Figure 142. MSP Schema Creation

Page 244: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

196

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

In this release two MSP Protection Schemas are supported:

– MSP 1+1 standard

– MSP N:1 standard (only for 1660SM)

Select one and then click on Add Port button in the Ports field to create a MSP schema.Figure 143. on page 196 is opened.Following steps are necessary:

– choose Port

– select a Port Role (protected or protecting)

– define Channel Id (mandatory for MSP N:1)

– define SDH Priority (type of traffic, High or Low)

Figure 143. MSP schema creation Port dialog

Select the Choose Port button to define the “Protected Port” and “Protecting Port” units.Figure 144. on page 197 is opened.

Page 245: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

197

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 144. TP Search (example)

Click on Rack–Subrack and select the Board ( Protected / Protecting ) on the “Equipment” window (leftside).The “termination Points” list (right side) is available.

On this right side select the OpS TP of the chosen board and then click on the OK button. It is possibleto select the board through the “Board History” button selecting the board list menu.

The “Filter Section” is divided into different fields. It permits to visualize a reduced TP Class. If used, OpSclass must be selected. The complete TP research description is reported in the “Transmission View”chapter 14.5.1.2 on page 223.Click on the OK button and repeat the operation for both “Protected Port” and “Protecting Port”. If it hasbeen selected a Protected/Protecting port configured in a previously MSP schema protection an errormessage of access denied will be appear on the screen.

In the dialogue of Figure 142. on page 195 also configure the MSP protection schema with the chosenProtection Schema and enter the related Schema Parameters according the following rules:

– 1+1 Standard can be:

• single–ended, Not Revertive for 1640FOX, 1650SMC, 1660SM• dual–ended , Not Revertive for 1660SM

– N :1 Standard can be only dual–ended Revertive (not supported by 1640FOX, 1650SMC)

At the end click on the OK button to confirm the MSP protection schema configuration. An error messagewill be appear if the selected schema is not supported by the NE.

Page 246: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

198

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 145. MSP 1+1 standard protection schema (example)

Figure 146. MSP N:1 standard protection schema (example)

Page 247: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

199

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

13.4 MSP Management

Select the MSP Management option from the Port –> MSP menu ( see Figure 147. on page 199 ) toopen the MSP Schema Configuration (see Figure 148. on page 200).

Figure 147. MSP Management Option

The MSP Schema Configuration dialog shows the current state of the MSP schema, settings and state(protected or protecting) of the current SDH-n port.

This dialog allows to set the configuration parameters for the designated multiplex section:

– Protection Schema reported in the previous paragraph 13.1 on page 193.

– Schema Parameters:

• Dual Ended / Single Ended protection switch and directionality.

• Revertive/Non Revertive mode.

• The WTR Time (Wait To Restore) is the delay time for switching protection and protecting portafter recovery from failure / defect.

• Enable Switch on SD is not operative in current release.

– Ports area display the current MSP schema:

• Port Id: identify the location of the board

• Role: identify the role of the board (“Protecting” or ”Protected”)

• Channel Id: mandatory for MSP N:1 (max. value is 14)

• Priority: type of traffic, High or Low

Configure the MSP protection Schema with the chosen protection schema and enter the related schemaparameters. At the end click on the OK button to configure the MSP protection schema. An error messagewill be appear if the selected schema is not supported by the NE.

Page 248: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

200

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 148. MSP Management View (example)

13.4.1 MSP modification

The same MSP Management option can be used to modify the schema parameters of an active MSPconfiguration.

Before changing a single ended (unidirectional) schema into a dual ended (bidirectional), all activeswitches must be cleared (manual switch, lockout,... ). If the operator wants to change the protectionschema architecture or the ports involved in the MSP schema, the current schema must be removed andre–created.

Page 249: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

201

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

13.5 MSP Delete

Select the MSP Delete option from the Port –> MSP menu (see Figure 149. on page 201) to open the“MSP Schema Deletion” (see Figure 150. on page 201).

Figure 149. MSP Delete option

Figure 150. MSP Schema Deletion (example)

Click on “OK” button to delete the selected MSP Schema Configuration

Page 250: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

202

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

13.6 Display of Protection State

The MSP protection state of a port is displayed at the bottom of the Port view. Some examples are reportedin Figure 151.

The following states are always displayed:

Port Status – Active (red color) or Standby (orange color). The active protection status is referredto a protected/protecting port ( where the traffic is transported): when a failure is detected, theprotecting port is ready to save the traffic (and becomes active). The standby protection status isreferred to a protecting/protected port that is ready to save the traffic.

MSP Protection Role – Protected (green color) or Protecting (ochre color). The protection roledepends on the selected port type (Protected / Protecting).

MSP Group Status, MSP Own Unit and MSP Related Unit – (green color) Displayed if an automaticswitch is requested. “Own Unit” stands for the currently displayed unit in the port view, “Related Unit”stands for the related unit of the same protection group . The status indications are:

NR: (abbreviation of No Request); normal, idle condition, the traffic is on the main portDNR:(abbreviation of Do Not Revert); the SF or SD have been recovered but the traffic isswitched on the spare portPF: a protection failure has been detected on the portRF: a release command has been failedFOP: a failure of protocol has been detected

complete: = the bridge/switch actions are completedpending: = the bridge/switch actions are pending

The “complete” and “pending” indications precede the following statuses:AS: automatic protection switching enabledMS: a manual local protection command has been activatedFS: a forced local protection command has been activatedLO: a lockout local protection command has been activated

SF/SD: Signal Failure or Signal Degraded has been detectedWTR: wait time to restore status

MSP Request Source – (green color) indicates where the operator commands (force/manual/lockout)have been performed. Only present when a command is operative.– Local: switch due to near end SD/SF or local user switch command– Remote: switch due to received K1/K2 bytes.

A remote switch cannot be released locally, but can be overwritten by a switch with higher priority.

MSP Protocol Status

This parameter indicates the current APS Protocol status.The following values are possible:– OK– Failure (in case of FOP)

Page 251: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

203

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

MSP statuses displayed in a normal conditions

MSP statuses displayed after an automatic protection switching

MSP statuses displayed after a forced command

Figure 151. MSP Protection Status Examples

Figure 151. represents a MSP configuration with a normal condition, with an automatic protectionswitching and with a forced command. In any situation are represented the statuses displayed on bothprotected/protecting Port views. The Active status indication, with a forced command on the protectinggroup, shows where the forced command is applied.

Page 252: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

204

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

13.7 MSP Commands

Select the MSP Commands option from the Port –> MSP menu ( see Figure 152. on page 204 ) toopen the “MSP Commands window” (see Figure 153. on page 205).

Figure 152. MSP Commands option

Protecting Port : the location of the board hosting the protecting port is displayed.

Protected Port : the location of the board hosting the protected port is displayed.

The Lockout of protection command denies working channel access to the protection section by issuinga “Lockout” of protection request (on the “Protection Status” of MSP Management).It is possible to “Lockout the Protecting Port” or “Lockout the Protected Port”; to remove the lockoutcommands select Release Ping (for the protecting) and Release Ped (for the protected).

The Force to command switches the working channel (Protected port) to the protection section(Protecting port), unless an equal or higher priority switch command is in effect or SF condition exits onthe protection section, by issuing a “Forced” switch request for that port (on the “Protection Status” ofMSP Management). It is also possible to switch back to the working channel using again the “Force to”Protected port command.For 1+1 non–revertive system, forced switch no working channel transfers the working channel back fromprotection to working section, unless an equal or higher priority request is in effect. Since forced switchhas higher priority than SF or SD on working section, this command will be carried out regardless of theworking section condition.

The Manual to command switches the working channel (Protected port) to the protection section(Protecting port), unless a failure condition exits on the protection section or an equal or higher priorityswitch command is in effect, by issuing a “Manual” switch request for that port (on the “Protection Status”of MSP Management). It is also possible to switch back to the working channel using again the “Manualto” Protected port command.For 1+1 non–revertive system, manual switch no working channel transfers the working channel back fromprotection to working section, unless an equal or higher priority request is in effect. Since manual switchhas lower priority than SF or SD on working section, this command will be carried out only if the workingsection is not in SF or SD condition

Page 253: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

205

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The Clear WTR command cancel the delay time for switching protection and protecting port afterrecovery from failure/defect.

The Exercise command issues an exercise request for protection channel and checks responses on MSPbytes, unless the protection channel is in use. This check controls the k1/k2 communication protocolfunctionality to be sure that the protocol is right also on the protection section.Not Operative in current release.

The Release command clears all previously switching commands.

Figure 153. MSP Commands (example)

The priority levels for the MSP commands are (from the higher to the lower one): Lockout, Force to,Auto–switch (SF&SD), Manual to.

Table 3. on page 205 gives the priority rules when are occurred two different commands. The first columnon the left and the first row at the top report the switch protection and the external MSP commands. Therow/column crossing gives the command or protection result (i.e.: if an “Auto–switch” and a “Manual to”command are present, “Auto–switch” is operative.

Table 3. MSP commands and Auto–switch protection priority

Lockout ofprotection

Forced to Auto–switch Manual to

Lockout ofprotection

–––––––––– Lockout Lockout Lockout

Forced to Lockout –––––––––– Forced Forced

Auto–switch

Lockout Forced ––––––––––– Auto–switch

Manual to Lockout Forced Auto–switch –––––––––––

Page 254: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

206

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

13.8 MSP overview

MSP Overview allows to display as well as search for MSP states.

Selecting the MSP Overview option from the Configuration pull down menu Figure 154. opens

Figure 154. MSP overview

To Search the MSP groups two different ways of filtering are supported; a filtering for all protection unitslocated on a dedicated Board Type as well as a filtering for protection units carrying a specific Status.

The search criteria can be chosen with the help of a combo box:

– Board Type: allows to filter for the MSP protected boards (example P4ES1N, P4E4N, L–41N,Ignore, etc.)

Page 255: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

207

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Status: allows to filter for all possible MSP protection states;the following filters values should beoffered (examples):

• Ignore• NR (Normal)• DNR• Auto–SF• Auto–SD• Auto–WTR• Manual• Force• Lockout• APS Invalid (Fail)• Bad channel (Fail)

After the filter selection click on Search button to start; the field below the Search button will be updated(see Figure 138. )

Figure 155. MSP overview after Search (Example)

Page 256: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

208

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Each protection unit is presented with the following information:

– Protection Group (example protection GroupId, 137)

– Port Id (example r01sr1sl33/port#02–OpS )

– Role:

• Ped Protected• Ping Protecting

– Status (board status):

• A (Active)• S (StandBy)• F (Faulty)• ET Extra Traffic (Not operative)

– Protection Status: defines the current state of the protection unit as follow

• NR (Normal)• DNR (Do Not Revert)• Auto–SF (AutoSwitch Signal Fail)• Auto–SD (AutoSwitch Signal Degrade)• Auto–WTR (AutoSwitch Wait Time To Restore)• Manual (Manual Switch)• Force• Lockout• APS Invalid (Protection fail condition APS invalid)• Bad channel (Protection fail condition Channel Mismatch)

The colors used for each row have the following meaning:

– Green (OK): for protected protection units active

– Red (Critical): for protected protection units in fail condition, protection unit in lockout or activeon autoswitch or commands

– Orange (Major): for protected units in standby after a command and protecting protection unitin standby for autoswitch or commands

– Cyan (Indicative: for protecting protection unit active and no fail condition present in the schema(Do Not Revert State)

At the bottom of the MSP Overview windows are available five button that allows to navigate through theMSP management views and to open the Port View.By clicking on Open Port View the operator has a quick link towards the view showing the correlationbetween the alarms and the protection states.

N.B. Before to click on one of the five buttons select a row

Page 257: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

209

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The buttons available are:

– Open Port view: opens the port view showing the correlation between the alarm and the MSPprotection states. See Figure 156. on page 209.

– MSP Create: opens the MSP Create dialog box. See Figure 142. on page 195 and the relevant description.

– MSP Delete: opens the MSP Delete dialog box. See Figure 150. on page 201 and the relevant description.

– MSP Management: opens the MSP Management dialog box. See Figure 148. on page 200 andthe relevant description.

– MSP Commands: opens the MSP Commands dialog box. See Figure 153. on page 205 and therelevant description.

Click on Close button to exit from the MSP Overview window

Figure 156. Port view after “Open Port View” command (example)

Page 258: 1660 S M  Oper  R4

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

210

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 259: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

211

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14 TRANSMISSION VIEW

14.1 Overview

This section describes the operations necessary for the consultation, modification and configuration ofTPs, providing a representation of the entire signal flow.

The generic Transmission View, described in this chapter, offers the possibility of displaying a single TPor a set of all kinds of TPs (or collected functionality which is represented by one/several TPs).

To display the termination points in the Transmission View, either select specific TPs from a TP searchdialog or access the view directly from another view, e.g. by navigating from the Port View.

The Transmission View provides the following features:

– Brief overview regarding transmission resources.

• An overview concerning all TPs belonging to a port can be called in by activating the functionto expand the selected TP. TP names are listed in an additional information area if the mousepointer is positioned over it. The following states are indicated (see Figure 157. on page 212):

– the alarm state is indicated by the alarm synthesis icon– the cross-connection state is indicated by a cross– whether a TP can be structured is indicated by a circle– whether a TP is under Performance Monitoring indicated by a blue “P” letter– whether a TP is involved in a loop action, it is indicated by a back–folded arrow

• An overview concerning signal flow can be requested by a user action. The user can selecta TP and apply the action Transmission –> Show Cross-connected TPs. The result is thatthe objects related to the TP are displayed and lines indicate the connections. Expanding andhiding TPs that are related to the currently selected TP (e.g. show all TPs that are above theTU-12 CTP) enables all related TPs to be added to the view, thus providing a representationof the entire signal flow.

– Display of single or multiple termination points.

• Search for and select a termination point in a TP search dialog and display it in the TransmissionView.

• Pop-up the Transmission View from the board view. All TPs/compound TPs associated with thephysical port are displayed (i.e. TPs down to AU-4).

– Provide the functionality to create/show cross-connections.

– Provide the functionality to create/show Multiplex Section Protection

– Provide the functionality to create/show Loopback commands.

– Provide the possibility of configuring a selected TP. This functionality is accessed by calling theconfiguration dialogs of the common Transmission/Port Views category.

– Provide the possibility of showing a detailed view of a TP with alarms, navigating to the Port view.

– Provide the possibility of showing and setting Performance Monitoring parameters and data.

Page 260: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

212

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.2 View elements

The Transmission View uses the symbols illustrated in Figure 157.

��������������� ������������

���������������

�������������������

��������������������������������������

�����������������

������������������������� ���������������

���

���������� ����������

� ������������������������������

Figure 157. Symbols Used in Transmission View

Page 261: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

213

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.3 View Layout

The Transmission View is a main view. It provides views of specific areas, which display the transmissionresources, and the specific Transmission View pulldown menu which provides the Transmission Viewoperations.

14.3.1 View Description

Figure 158. illustrates the Transmission View area. TPs that are received from the network element aredisplayed in the Transmission View with the respective TP and connection symbols described inFigure 157. The number of TPs presented initially depends on whether the Transmission View is poppedup from a board view, whether a TP has been selected in another view or whether it is called without aselected TP.

When the “Transmission view” is reached selecting the Transmission option in the View pull down menuin its initial state contains no objects.

Figure 158. Transmission View Area (example)

Page 262: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

214

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.3.2 Number of TPs Displayed in Transmission View

It is possible both to expand a VC-4, thus displaying all underlying TPs, and to hide TPs which are of nointerest. The objects initially displayed depend on the situation/definition.

14.3.3 Naming TPs

The following rules are applied in order to identify the TPs displayed:

– the root node contains the full user label,

– all child nodes contain a short label indicating the position inside the tree.

14.3.4 Dynamic View Behavior

The following section describes the view states and provides a short description of events that affect theview.

14.3.4.1 Initial state of the view

In its initial state, the Transmission View contains no objects when it is reached selecting theTransmission option in the View pull down). Objects can be searched for and displayed using the AddTP dialog.

14.3.4.2 Working state of the view

In its working state, the Transmission View already contains objects. If the operator searches for anddisplays a TP using the TP Search dialog, the view is first initialized again and then the TP is displayed.The same applies in the case of navigation from another view to the Transmission View – the TransmissionView is always initialized and the corresponding objects are then displayed in it.

14.3.4.3 Navigation to Transmission View from other views

If the Transmission View is popped up from the Port View, only the selected TP is displayed.

14.3.4.4 Alarm notification

Alarms concerning the TPs displayed are indicated graphically by the alarm synthesis icons of the TPobjects. The TP objects are updated accordingly.

14.3.4.5 Object deletion

All kinds of object deletion events related to TPs displayed are indicated by the TP objects. The graphicalobjects are removed accordingly from the Transmission View. Example: modification of the payloadstructure from 63 TU-12 to 3 TU-3.

Page 263: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

215

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.4 Transmission view access and menu

The “Transmission view” can be reached selecting the Transmission option in the View pull down menu.In this case, in its initial state, the Transmission View contains no objects.

In the case of navigation from another view (example the “Port view”) to the Transmission View, theTransmission View is always initialized and the corresponding objects are then displayed in it (see forexample Figure 158. on page 213.)

Selecting the “Transmission” option in the menu bar of Figure 158. on page 213. the complete pull downTransmission menu is presented (Figure 159. )

The following menu items are available:

– Add TP Select the TP to show on the Transmission view.It is described in the following paragraph.

– Expand Display TPs that are related to the selected TP.It is described in this chapter, see para 14.13.1 on page 249.

– Hide Hide TPs that are related to the selected TP or the selected TP.It is described in this chapter, see para 14.13.2 on page 250

– Port Mode Configuration: This functionality allows to manage the alarms behaviour on LOS according to the setup done at port level.Refer to paragraph 11.4 on page 144.

– TP Configuration Set parameters for the Overhead on Synchronous TP’s.It is described in this chapter, see para 14.6 on page 227

– TP Frame Mode Configuration: Set parameters for 2Mbit/s G.703/G.704 or ISDN–PRAmanagementSee para. 11.8 on page 170

– TP Threshold Configuration Set B2 ExBER and Degraded Signal parameters.It is described in this paragraph, see para.14.7 on page 234.

– Terminate TP Terminate a path on a AU-4 CTPIt is described in this chapter, see para 14.8 on page 235

– Disterminate TP Disterminate a path on a AU-4 CTPIt is described in this chapter, see para 14.8 on page 235

– AU4 Concatenation: See paragraph 11.6 on page 148

– Cross-Connection Manage the connection of the paths. See para. 15 on page 253

– Monitoring Operations Create, configure and delete POM, SUT,TCT,TCM TP’s.It is described in this chapter, see para 14.9 on page 236

– Performance Set and show Performance Monitoring parameters and data.See chapter 17 on page 313.

– Structure TPs Provides the possibility of structuring and destructuring selected TPIt is described in this chapter, see para 14.10 on page 241

– Loopback Manage the loopback commands, for commissioning ormaintenance purposes. See paragraph 14.11 on page 242.

Page 264: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

216

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Physical Media Manage the physical TP setting. See para 14.12 on page 247.

– MSP Manage the Multiplex Section Protection of the NE. Not available for PDH port

See paragraph 13.4 on page 199. In this paragraph is not describedthe MSP>NE MSP synthesis option of the Transmission menubecause not used in this NE.

– Show Supported Board Navigate to the upper board level.It is described in this chapter, see para 14.13.3 on page 251

– Navigate to Port View Permit to show the detailed alarm of the TP.It is described in this chapter, see 14.13.4 on page 252

These options are described in next paragraphs except the previously referenced.

Figure 159. Transmission menu options

Page 265: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

217

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.5 ADD TP

Select the Transmission –> Add TP option.

This menu item opens the TP Search dialog (see Figure 160. ). The TP Search dialog enables the userto search for and add a TP to the Transmission View (e.g. search for all TPs on a board with PM enabled).

14.5.1 TP Search

14.5.1.1 Default Mode

In this mode, the dialog displays the structure of the equipment tree. After double-clicking, e.g. on a port,the contents of the port appear on the right-hand side of the dialog (TP list). To keep the number of itemsdisplayed small, they are displayed in a hierarchical order. Double-click again to recall the next level (seeFigure 162. ).

Figure 160. TP Search Dialog, Initial State

After double-clicking on an object, an Information window appears (see Figure 161. ). The message textcorresponds to the object selected.

Page 266: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

218

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 161. Information Window (example)

The search can be stopped with Cancel.

It is possible to select several individual TPs from the TP list by clicking on them while holding down theCtrl key on the keyboard. To select a block of TPs, click on the first TP and then click on the last TP in theblock while holding down the Shift key on the keyboard. But only the first TP selected in the list will beshown in the Transmission View.

Figure 162. TP Search Dialog with Various TP Selections

Page 267: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

219

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

After clicking on Show CC State, a more detailed TP list is displayed (see Figure 163. ) containing TPcross connection status information.

Figure 163. TP Search Dialog with Status Information Displayed

The symbols in the TP list have the following significance:

����������

�����������������

�����������������������������

����������

Figure 164. Symbols in TP Search

Page 268: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

220

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

After clicking on Show Mon, a more detailed TP list is displayed (see Figure 165. ) containing TP undermonitoring with relevant type information (example TCT, POM, SUT, etc.)

Figure 165. TP search window: Show Monitoring details (example)

After clicking on Show PM, a more detailed TP list is displayed (see Figure 166. ) containing the TPs underPerfomance monitoring with relevant performance type information ( example near end 15 min, Far–end15 min., 1 day Near–end etc.)

Figure 166. TP search window: Show Performance Monitoring details (example)

Page 269: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

221

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

An easy way to recall to previously displayed boards is to use Board History ( refer to Figure 167. on page 221 ).

Select the relevant board from the list.

Figure 167. Board History Check List

Filter criteria for ASAP feature, allow to search objects that has a specified ASAP value (exampleFigure 168. ). The object classes we are interested in are the ones choosed by the ”Class” option menuand Monitoring objects, PM objects and Equipment if the check boxes in the ”ASAP search” frame arechecked.

The option menu ”ASAP value” is made by the following items :

– Ignore (the search aimed to ASAP value is disabled)

– (No Alarms)

– Primary Alarms)

– (No Remote Alarms)

– All Alarms)

– #10001 (if exists)

When a selection different by ”Ignore” is done, all criteria, except ”Class” option menu and the check boxesrelated to Equipment/PM/Monitoring objects, are grayed.

Page 270: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

222

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 168. TP Search: ASAP search filtering

Page 271: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

223

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.5.1.2 Search Mode

Use Search Mode together with the filtering options provided below the TP list (see Figure 169. ). Thefollowing options are available:

– Class:

Ignore, E1S, OpS, PPI, AU-4, VC-4, AU-4+VC-4, TU-3, VC3, AU3 & TU3 & VC3, TU-3+VC-3, TU2,TU-12, VC-12, TU-12+VC12, AUX, MS, RS, OGPI, GMAU.

– Connection State (Current connectivity status):

Ignore, not connected, connected

– Alarm State (Path Trace):

Ignore, critical, major, minor, warning, not alarmed

– Assign State:

Ignore, NML, EML; not used

– Perf. Monitoring (Performance Monitoring condition):

Ignore, Any, None

– Monitoring Object:

Ignore, POM, SUT, TCT, TCM, Any; None.

– Location:Permits to insert the location of the TP in the following format:r<rack#>sr<subrack#>sl<slot#><port#>

– Name: not supported

Page 272: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

224

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 169. TP Search Dialog with Different Filtering Options

After activating the search process with the Search TP button, the following dialog box appears. Thesearch can be interrupted by clicking on Cancel.

Figure 170. “Information...” Dialog for Search Process

N.B. When searching for PM-enabled TPs on NE, Rack or Subrack, the time for the request can bevery high. It is recommended to search for PM-enabled TPs at the board level (a board isselected for the search).

Page 273: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

225

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.5.1.3 Common Buttons

The following buttons are available in all modes:

14.5.1.3.1 Ok

Closes the dialog and opens the Transmission View containing the selected TP, as for the example ofFigure 158. on page 213.

14.5.1.3.2 Close

Closes the dialog without updating the Transmission View.

14.5.1.3.3 Print

This command is used to generate and print a list of TPs according to the current filter selection (refer toFigure 173. for an example of a printout).

The command opens the following dialog:

Figure 171. Print to Printer

Select the desired printer from the list box and click on Ok to start the print job or abort with Cancel.

The dialog changes after clicking on File:

Figure 172. Print to File

Enter the name of the output file in the input field or select a file name from the File Select dialog by clickingon Select file. Select if the output format should be Postscript or ASCII.

Page 274: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

226

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The output file is generated after clicking on Ok. Use Cancel to stop the process.

Figure 173. Example Printout

14.5.1.3.4 Help

This command opens the online help for the TP-Search dialog.

Page 275: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

227

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.6 TP Configuration

Select the desired TP and then the Transmission –> TP Configuration option.

TP Configuration can also be accessed from the “Port” view menu.

14.6.1 High Order TP Configuration

Depending on the TP selected, a dialog appears for the configuration of the main parameters of thefollowing objects:

– VC-4 TTP (Matrix resource)

– VC-4 TTP (140 Mbit/s PDH) (not available on 1640FOX)

– VC-3 TTP (34 and 45 Mbit/s PDH)

The main parameters are:

– C2 Signal Label: “Automatic” (decided by the NE) or “Equipped not specific”.

– J1 Path Trace.

The dialogs of the following figure appears:

Figure 174. High Order TP Configuration

Page 276: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

228

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.6.1.1 J1 Path Trace

If the Path Trace is 16 bytes long, the first byte is a CRC7 checksum calculated by NE.

If the Path Trace is shorter than 16 bytes, it is filled with zero bytes (”0” hexadecimal).

Received fields is read only.

With the relevant button the operator can set the Expected field as:

– TTI Enable– TTI Disable– TTI Repeated

The Transmitted field can be set with TTI Enable or TTI Repeated byte

Empty TTI button permits to send an all zeroes path trace.

To replace modified with the default, enter the default manually according to the following table.

Table 4. Default value for C2/V5 Signal Label

TP VC–4 TTP / AU4 CTP(SDH)

VC–4 TTP(PDH)

VC3–TTP VC–12 TTP

Significant Byte C2 C2 C2 V5

Default value 2 18 4 2

Click on Hex button Figure 175. will be opened displaying in hexadecimal code the same value reporedin Trasmitted and Received field.

Figure 175. J1 hexadecimal editor (example)

Page 277: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

229

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.6.1.2 C2 Signal Label

Received and Expected fields are read only.They can display the following number, according the G.707 recommendations for the C2 Signal Label:– 0: Unequipped– 1: Equipped non-specific– 2: TUG structure– 3: Locked TU-n– 4: Asynchronous 34/45Mbyte– 18: Asynchronous 140Mbyte– 19: ATM– 20: MAN, DQDB– 21: FDDI.

In the Transmitted field it is possible to select the values:• Automatic: the C2 Signal Label value is automatically selected by the NE according the VC

structure.• Equipment not specific (it corresponds to number 1)

Page 278: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

230

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.6.2 J0 Section Trace management

Select RST block and then select Port–> TP Configuration.

The fields of the following figure appears:

Figure 176. J0 Configuration

This function is implemented in order to manage the J0 Trace configuration.This dialog shows the current values for received, expected and transmitted trail trace and it allows theoperator to change only the values of expected and transmitted trail trace.The received trail trace is read–only.Expected and Transmitted fields are editable by the operator.With the relevant button it is possible to enable or disable TTI Monitoring.

Click on Hex button Figure 177. will be opened displaying in hexadecimal code the same value reporedin Trasmitted and Received field.

Figure 177. J0 hexadecimal editor

Page 279: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

231

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.6.3 Low Order TP Configuration

Depending on the TP selected, a dialog to configure the main parameters of the following objects:

– VC-12 TTP.

Select the desired VC12 and then the Transmission –> TP Configuration option.

The main parameters are:

– V5 Signal Label. “Automatic” (decided by the NE) or “Equipped not specific”.

– J2 Path Trace.

The following dialogs appears:

Figure 178. Low Order TP Configuration

Click on Hex button Figure 179. will be opened displaying in hexadecimal code the same value reporedin Trasmitted and Received field.

Page 280: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

232

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 179. J2 hexadecimal editor

Page 281: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

233

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.6.3.1 J2 Path Trace

If the Path Trace is 16 bytes long, the first byte is a CRC7 checksum calculated by the NE.If the Path Trace is shorter than 16 bytes, it is filled with zero bytes (“0” hexadecimal).

Expected and Transmitted fields are editable by the operator.Mode1 enable the 16 bytes long sequence for Path traceOne repeated byte allows to set one byte that will be repeated.

Received fields is read only.

With the relevant button it is possible to enable or Disable TTI Monitoring.

Empty TTI send an all zeroes path trace.

14.6.3.2 V5 Signal Label

Received, Expected and Transmitted fields are read only.

They can display the following number, according the G.707 recommendations for the V5 Signal Label:

– 0: Unequipped– 1: Equipped non-specific– 2: Asynchronous– 3: Bit Synchronous– 4: Byte Synchronous

In the Transmitted field it is possible to select the values:

• Automatic: the C2 Signal Label value is automatically selected by the NE according the VCstructure.

• Equipped not specific (it corresponds to number 1)

To replace modified with the default, enter the default manually according to the value reported inTable 4. on page 228.

Page 282: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

234

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.7 TP Threshold Configuration

This menu allows the operator to set the alarm thresholds for MST and VCi layer.

Select an MST block, or VC12, or VC3, or VC4.

Select the Transmission –> TP Threshold Configuration option.

Figure 180. will be opened.

The user can select one of the two different Defect distribution:

– Poisson distribution enable configuration of the Excessive Bit Error Ratio (ExBER on MST, VCi)threshold and Signal Degrade (SD on MST, VCi) threshold of the TP’s related counted primitives.

– Bursty distribution enable configuration of the maximum number of errored frames and the totalamount of bad block per frame.

– (*) ExBER – Threshold : 10–3 to 10–5

– Enable Consequent Actions : fixed to enabled

– (*) Signal Degrade – Threshold : 10–5 to 10–9

– Bursty Parameters – Threshold : 1 or 10 or 100 or 1000

– Bursty Parameters – Consecutive Bad Seconds : 2 to 10

Note (*): the ExBER and Signal Degrade may be: “B2” for MST, “B3” for VC4 and VC3, “BIP12” for VC12.

Figure 180. Degraded Signal Threshold selection (example)

Click on Ok to confirm the chosen parameters.

Page 283: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

235

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.8 Terminate/Disterminate TP

Select the Transmission –> Terminate TP or Disterminate TP option.Only one command in the menu is available, depending on whether a TP is terminated or not.

14.8.1 Terminate TP

Use this action to terminate a path. It can be performed on a AU-4 CTP.A cross-connection between the selected AU-4 CTP (= aTP) and a modifiable VC-4 TTP (= bTP) iscreated. Three TUG-3 and TU-3 are created if the modifiable VC-4 TTP was not already structured.A cross appears in the icon of the terminated TP:

If the TP is already cross-connected a error message appears.

14.8.2 Disterminate TP

Use this action to disterminate a path. It can be performed on a AU-4 CTP. The related cross-connectionis deleted.

NOTE: the “Disterminate” action is not possible in the case that is still existing anyoperation/connection/termination on the underlying signals, such as:• Performance Monitoring on lower or higher TPs• POM / HPOM operations• Lower order Connections• Higher order Connections• Lower/Higher order Path Terminations• Loop–backs on lower TPsThus the deletion of every operation/connection/termination is necessary, in the same order as abovelisted, before disterminating a TP.

A box message will be presented, in order to confirm the TP distermination .

Page 284: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

236

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.9 Monitoring Operations

Select the Transmission –> Monitoring Operations option as for the following figure.

Creation/Deletion and Configuration options are presented.

Monitoring Operations can also be accessed from the “Port” view menu.

The commands of this menu item are for the management of the POM, SUT, TCT, TCM functions (PathOverhead Monitoring, Supervised Unequipped Termination, Tandem Connection Termination/Monitoring;SUT function is not operative).

This command is available for:

– AU4 CTP (High order POM before and after matrix; TCM before and after matrix)

– AU4–4c CTP (High order POM before and after matrix; TCM before and after matrix)

– AU4–16c CTP (High order POM before and after matrix; TCM before and after matrix) only for1660SM

– TU-3 CTP (Low order POM before and after matrix;TCM before and after matrix)

– TU-12 CTP (Low order POM before and after matrix; TCM before and after matrix)

– VC–4 (TCT after matrix)

– VC–3 (TCT after matrix)

– VC–12 (TCT after matrix)

Page 285: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

237

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.9.1 Creation/Deletion

This dialog allows multiple object creation/deletion.The dialog shown in the following Figure 181. opens:

Figure 181. Monitoring Operations Creation/Deletion

The Path Overhead Monitoring has the following parameters:

– Before Matrix– After Matrix

The Supervisory Unequipped Termination, not operative in current release, has the following parameters:

– Sink (before matrix)– Sink (after matrix)– Source– Bidirectional

The Tandem Connection has the following configurable parameters:

• Tandem Connections Monitoring (TCM):– TCM Before Matrix– TCM After Matrix

• Tandem Connection Termination (TCT):– TCT Bidirectional Before Matrix– TCT Bidirectional After Matrix

Press Ok to apply the parameters or Close to close the dialog and discard the not with Ok appliedchanges.

Page 286: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

238

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The TP list... button opens the Clipboard window; refer to paragraph 4.3.2.3 on page 59 about the useof the Clipboard.

When select and apply the Path Overhead Monitoring, the changes will be displayed in the Port View inthe following manner:

Figure 182. Display of POM and TCM in Port View (example)

When select and apply the Tandem Connection Monitoring / Tandem Connection Termination, thechanges will be displayed in the Port View in the following manner:

Figure 183. Display of POM and TCM/TCT in Port View (example)

Also refer to para. 11.11 on page 175, about navigation to Monitoring View.

Page 287: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

239

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.9.2 Configuration

Depending on the parameters selected in the Monitoring Operations Creation/Deletion dialog, not allsections of the dialog are available.

NOTE: It is possible to open the POM and TCT/TCM Configuration dialog for a CTP even if neitherPathOverheadMonitor nor Tandem Connection was created before (SUT isn’t available in thisrelease). No changes can be made in this case and the values displayed can be ignored.

Figure 184. Monitor Configuration

Page 288: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

240

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– TTI Definition

The TTI (Trail Trace Identifier) has a maximum length of 16 characters.

The following TTI Definitions are available:

• TTI Expected• TTI Received without the display• TTI Sent

The following TTI Types are available:

• TTI Enabled• TTI Disabled• TTI Repeated Byte

– Error Distribution

Poisson and Bursty error distribution are supported.

– TCM/TCT ConsActions

It is needed to support explicit consequent action activation (AIS insertion) for TCT sink andbidirectional.

– Thresholds

Set the thresholds of the following parameters:

• Signal DegradePoisson mode only: from 10–5 to 10–9.

• Excessive ErrorPoisson mode only: from 10–3 also if presented a selection from 10–3 to 10–5

• Bursty DegradeSelect a value between 1 and 1000 errors/sec for the Bursty Degrade threshold.

• Bursty ConsecutiveSelect a value between 2 and 10 sec for the Bursty Degrade Consecutive.

– Alarm Timing

Raising and Clearing Timing are not supported by OMSN.

– Unequipped Trail

Not available.

Page 289: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

241

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.10 Structure TPs

Select the Transmission –> Structure TPs option as for the following figure.

This menu item provides the possibility of structuring and destructuring a selected TP. The level that isselected defines how the signal is to be structured, e.g. if a VC-4 TTP is selected and the menu item TU-12is chosen, the signal is structured down to 63 TU-12 CTPs. The following menu items represent all thosepossible:

– TU-2. Not supported.– TU-3.– TU-12.– AU3. Not supported.– AU4. Not supported.– VC-3/VC-4. Not supported.– VC-12. Not supported.

Page 290: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

242

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.11 Loopback

The commands of this menu item are for the management of the loopback commands, for commissioningor maintenance purposes.

14.11.1 Loopback Configuration

The loopbacks can be applied at line (external to equipment) level or at internal equipment level. Theloopback commands are used to separate the communication network into independent part checking theline/equipment functionality during the network installation or maintenance operation.

The loopback architecture provides four configurations ( see Figure 185. ).Line Loopback And ContinueLine Loopback And AISInternal Loopback And ContinueInternal Loopback and AIS

Line Internal Line

Line

Destination

Destination

Initial

Initial

Destination

AIS

Internal Line

AIS

Internal loop And Continue Internal loop And AIS

Line Loop And Continue Line Loop And AIS

Initial Destination

Initial

Figure 185. Loopback configurations

Page 291: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

243

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Table 5. Supported loopback

Port type Line Loop &Continue

Line Loop &AIS

Internal Loop& Continue

Internal Loop& AIS

STM–64(only on 1660SM Rel. 5.x)

OK Access Denied OK Access Denied

STM–16(only on 1660SM)

OK Access Denied OK Access Denied

STM–4 Access Denied OK Access Denied OK

STM–1 Access Denied OK Access Denied OK

140Mbit/s(not available on 1640FOX)

Access Denied OK Access Denied OK

34/45 Mbit/s OK Access Denied OK Access Denied

2 Mbit/s Access Denied OK Access Denied OK

Select a TP that supports the Loopback Configuration

Loopbacks act on the following TPs:

• PDH board (only from the Port View):– Line loopback performed on:

• P for 2/34/45/140 Mbit/s PPI (140 Mbit/s is not available on 1640FOX)

– Internal loopback performed on:• p12 for 2 Mbit/s CTP• p31 for 34/45 Mbit/s CTP• p4 for 140Mbit/s CTP (140 Mbit/s is not available on 1640FOX)

• SDH board:

The loopback configuration can be done only on SDH ports with the acronym endingwith a “ N” letter (i.e. P4S1N, S–4.1N, L–4.1N, L–4.2N, etc.)

– Line loopback performed on:• EIS for electrical STM–1 SPI• OpS for optical STM–1, STM–4, STM–16 SPI (only available on 1660SM), STM–64

SPI (only available on 1660SM Rel.5.x)

– Internal loopback performed on:• MsT TTP for STM–1, STM–4, STM–16 (only available on 1660SM), STM–64 (only

available on 1660SM Rel. 5.x)

Select the Transmission –> Loopback –> Port Loopback Configuration option as for the followingfigure.

Port Loopback Configuration can also be accessed from the “Port” view menu.

Page 292: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

244

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 186. opens.

Figure 186. Port Loopbacks View

Choose the TP clicking on the “Choose TP” button (the second “Choose TP” button is not available).Select the TP where to apply the loopback command. For the TP selection procedure, follow the TPresearch description reported in para. 14.5.1 on page 217. For this NE the “Timed Loopbacks” field isnot managed and thus Start/Stop loopbacks time is not editable.

Page 293: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

245

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.11.2 Loopback Management

To manage the loopback configuration select the Transmission –> Loopback –> LoopbackManagement option as for the following figure.

Loopback Management can also be accessed from the “Port” view menu and from the “Configuration”menu.

Figure 187. opens.

Figure 187. Loopback Management

Page 294: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

246

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The configured loopback are listed into the current loopbacks table. This table can be managed by the“Search” criteria, “Delete” and “Create” commands.

– Search Criteria (not operative): to configure the filter select the “Loop and Continue” type (Yes= LoopAnd Continue, No= Loop And AIS) then select the “Directionality” Internal or Line and edit the InitialTP Id (write: rack, subrack, board, port# and the TP type: EIS (SPI/PPI Electrical), OpS (SPI/PPIOptical), MST and so on. For “Initial TP” has to be intended the outgoing signal while for“Destination TP” the incoming signal. Enable the filter through the “Toggle Filter” Enable/Disablebutton. Click on the “Search” button to start the configured loopback research into the currentloopback table.

– The “Delete” command permits to delete a loopback listed in the Current loopbacks Table: select aloopback in the list and click on the “Delete” button.

– The “Create” command permits to create a new loopback configuration: clicking on “Create” theprevious figure ( Figure 186. ) opens. Follow the previously paragraph indications to create a newloopback configuration.

The activated loopbacks are signalled in the Port view and in the Transmission view as for the followingfigures:

PORT VIEW

Active Loopback

TRANSMISSION VIEW

Active Loopback

Page 295: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

247

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.12 Physical Media

Select the Transmission –> Physical Media option as for the following figure.

The Physical Media options permit to set physical configuration of each TP.

It opens a menu in which the various options will be available according the TP’s type (for the optioncommon with the “Port view” reference is made to the relevant paragraph):

– ALS Management. See para. 11.7.1 on page 152.

– Show Optical Configuration See para.11.7.2 on page 156.

– TX Quality Configuration See para.18.2.11 on page 375.

– Single Fiber Configuration. See para.11.7.3 on page 157.

– Extra traffic Not operative

– Regeneration Section management Not operative

– Line Length Configuration See para.11.7.5 on page 160.

– Set Domain See para. 14.12.1 on page 248.

– HDSL Configuration Not operative

– NT Configuration Not operative

– X21 Configuration Not operative

Page 296: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

248

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.12.1 Set Domain

This option is referred to the SECurity management and allows the user to set the Manager list and theAccess Control Domain of the selected TP.

Select the block: EIS for Electrical SDH port, OpS for Optical SDH port, P (PPI) for PDH port.

Select the Set Domain option from the Physical Media cascade menu to present the following view:

The dialog–box contains the following fields:

– NML Assignment: each connected manager to the TP is highlighted in the list. The user can set amanager clicking on the denomination.Several manager can be enabled contemporaneously, having in charge the TP.The Manager List contains the list of managers ( i.e. RM, SY, NPOS , EML) that work on the NE. TheEML–USM administrator (SH or Craft Terminal) should set the Manager List only to remove amanager in case of emergency (i.e. the Manager misses the NE connection).

– Resource domain field allow to select the domain among that displayed in the list, assigning it tothe TP.The different domains could be assigned to different operators.

OK button is used to validate the selection.

Cancel button close the dialog without changes of the data.

Help button provides some useful information about the dialog.

Figure 188. Set Domain

Page 297: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

249

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.13 Navigation Commands

14.13.1 Expand

Select the Transmission –> Expand option as for the following figure.

This menu item provides the possibility of displaying TPs that are related to the selected TP. These maybe TPs that are contained by the TP or TPs which belong to the physical port that is actually connectedto the TP.

– Show next level of lower TPs,

– Show all lower TPs,

– Show next level of upper TPs,

– Show all upper TPs.

Page 298: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

250

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.13.2 Hide

Select the Transmission –> Hide option as for the following figure.

This menu item provides the possibility of hiding all upper/lower TPs of a selected TP and the deletion ofa selected TP.

– Lower TPs,

– Upper TPs,

– Selected TPs.

Page 299: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

251

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.13.3 Show Supported Board

Select the Transmission –> Show Supported Board option.This menu provides the possibility of navigating directly to the board that supports the TP.

The Board View appears:

Figure 189. Board View (example)

Page 300: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

252

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

14.13.4 Navigate to Port View

Select the Transmission –> Navigate to Port View option.

This menu provides the possibility of navigating to the corresponding Port View related to the selectedTP in order to access a detailed overview of alarms quickly.

The Port View appears:

Figure 190. Port View

Page 301: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

253

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15 CROSS-CONNECTION MANAGEMENT

15.1 Introduction

15.1.1 Overview

The purpose of this domain is to manage the connection of the high and low level path.

The following chapters provide the user with information concerning operations on cross-connections:

– Para. 15.1.2 on page 254 “Multiplex Structures for SDH”gives an overview on the SDH technology

– Para. 15.1.3 on page 257 “Definition of Termination Points”gives an overview about the termination points implemented on the NE

– Para. 15.1.5 on page 262 “Cross-Connection Types”provides information concerning cross-connection types supported by the NE

– Para. 15.1.6 on page 264 “Cross-Connection Protection”provides information concerning cross-connection protection supported by the NE

– Para. 15.2 on page 266 “Operative sequence to execute Cross-Connections”details the complete procedure to realize cross-connection

– Para. 15.3 on page 270 “Cross-Connections Management”details the contents of the main cross-connections view

– Para. 15.4 on page 277 “Create/Modify Cross-Connections”describes the creation and modification of cross-connections

– Para. 15.5 on page 292 “Activate/Deactivate/Delete Cross-Connections”describes the activation, deactivation and deletion of cross-connections.Activation and deactivation not supported in current release.

– Para. 15.6 on page 293 “Split and Join Cross-Connections”describes how to split or join bidirectional cross-connections.

– Para. 15.7 on page 296 “Protection Switching”deals with switching actions (force, manual, lockout protection) on cross-connections

– Para. 15.8 on page 298 “Print”deals with printing out list entries on printers or into files

– Para. 15.9 on page 299 “Show Cross-Connected TPs”describes the possibility of showing connections between two or more TPs of different differenthierarchies, e.g. connection between au4 and vc4.

Page 302: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

254

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.1.2 Multiplex Structures for SDH

By introducing the Synchronous Digital Hierarchy (SDH), a standardized transmission has been created,matching the European with the American standard. The SDH signal structure contains an extendedoverhead as well as a fixed pointer controlled assignment of the user signal elements, thus improving thepossibilities of the network management.

Signals of the Synchronous and Plesiochronous Digital Hierarchy (PDH) are packed by synchronousmultiplexers into Virtual Containers (VC). The STM-1 signal structure is achieved by using the multiplexstructure complying with ITU-T and ETSI, (see Figure 191. ). Each of the user channels (2 Mbit/s, 34Mbit/s, 45 Mbit/s and 140 Mbit/s) is packed into a container synchronous to the STM-1 frame accordingto a predefined structure.

To adjust the plesiochronous signals to the synchronous network clock, certain filling algorithms areavailable. Fix fill bits are inserted into synchronous signals. A byte column (9 Byte) as Path Overhead(POH) is added to the Container (C) generated. Path Overhead and Container together form the VirtualContainer (VC). With the pointer pointing to the start of the VC, in respect of the STM-1 frame, anAdministrative Unit (AU) or – if several Containers of a group are to be combined – a Tributary Unit (TU)is generated. Several TUs form a Tributary Unit Group (TUG) and TUGs again can be combined into aVC. The AU of the signal, together with the Section Overhead (SOH), finally make up the STM-1 frame.

Page 303: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

255

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

STM

–NST

M–1

AU

–4V

C–4

C–4

TU

G–3

AU

–3V

C–3

C–3

TU

G–2

TU

–2V

C–2

C–2

TU

–12

VC

–12

C–1

2

TU

–11

VC

–11

C–1

1

TU

–3V

C–3

140

Mbi

t/s

(45

Mbi

t/s)

34 M

bit/s

6 M

bit/s

2 M

bit/s

(1,5

Mbi

t/s)

Leg

end:

C VC

TU

TU

GA

U

: Con

tain

er: V

irtu

al C

onta

iner

: Tri

buta

ry U

nit

: Tri

buta

ry U

nit G

roup

: Adm

inis

trat

ive

Uni

t

x1x3

x3

x3x1

x7

x7

x4

x1xN

Poin

ter

-Pro

cess

ing

not i

mpl

emen

ted

Figure 191. SDH Multiplex Structure according to ITU-T G.707

Page 304: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

256

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The STM-1 frame consists of:

– a Section Overhead (SOH)– an AU Pointer area– a payload area

Payload

Section Overhead

SOH

AU – Pointer

Section Overhead

SOH

270 Columns (Bytes)

9 rows

1 9 270

1

9

3

4

5

Figure 192. Frame Construction within the Synchronous Digital Hierarchy

The STM-1 frame has a basic bit rate of 155.520 Mbit/s. A single user channel is packed into a VirtualContainer. These Virtual Containers are of different size and may be nested or packed differently.

Virtual Containers for the European bit rates:

– the STM-1 frame contains a VC-4,– a VC-4 may contain one C-4 or three TUG-3,– each TUG-3 may contain one VC-3 or seven TUG-2,– each TUG-2 contains three VC-12 or one VC-2.

An STM-1 user signal can be constructed of:

– either 1 x VC-4– or 3 x VC-3– or 2 x VC-3 + 7 x VC-2– or 2 x VC-3 + 21 x VC-12– or 1 x VC-3 + 14 x VC-2– or 1 x VC-3 + 7 x VC-2 + 21 x VC-12– or 21 x VC-2– or 14 x VC-2 + 21 x VC-12– or 7 x VC-2 + 42 x VC-12– or 63 x VC-12.

STM-N signals are constructed by integer multiples of the basic signal STM-1 of 155.520 Mbit/s. Forexample an STM-16 signal of 2.488.320 Mbit/s is generated by combining sixteen STM-1 signals byteinterleaved.

Page 305: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

257

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.1.3 Definition of Termination Points (TP)

When ports are depicted on the user interface, the following abbreviations are used.

This section concerns the multiplex structure (see Figure 191. ) as well as on the information model ofobject-oriented programming which was used when forming the user interface. As a rule, a TerminationPoint (TP) is the starting and terminating point of a transmission segment. A distinction is made betweenthe following types of TPs:

– CTP (Connection Termination Point)The CTP represents the termination of a connection. The transmission signal is ”terminated”, i.e.,the received signal is monitored and the error signaling evaluated, while own-code signaling isinserted in the transmitted signal.

– TTP (Trail Termination Point)The TTP represents the termination of a transmission segment. The signal is monitored and passedon after modification in one form or another.

Both TP types exist on the SDH level and the PDH level.

– CTPs on SDH levelOn SDH level (see Figure 193. ) a distinction is made between the following CTPs:

• AU-4 (Connection Termination Point)The AU-4 CTP represents both the creation and termination of an STM-1 connection. TheHigh-order Connection Supervision (HCS) function is included.

• TU-x (Connection Termination Point), i.e. TU-12 CTP, TU-2 CTP, TU-3 CTP.The TU-x CTP represents both the creation and termination of a VC-x connection. TheLow-order Connection Supervision (LCS) function is included.

– CTPs on PDH levelOn PDH level (see Figure 194. ), a distinction is made between the following CTPs:

• E4 (Connection Termination Point)The E4-CTP represents the non–intrusive monitoring of incoming 140 Mbit/s PPI.

• S4 (Connection Termination Point)The S4-CTP represents the non–intrusive monitoring of outgoing 140 Mbit/s PPI .

• E32 (Connection Termination Point)The E32-CTP represents the non–intrusive monitoring of incoming 45 Mbit/s PPI.

• S32 (Connection Termination Point)The S3-CTP represents the non–intrusive monitoring of outgoing 45 Mbit/s PPI .

• E31 (Connection Termination Point)The E31-CTP represents the non–intrusive monitoring of incoming 34 Mbit/s PPI.

• S31 (Connection Termination Point)The S31-CTP represents the non–intrusive monitoring of outgoing 34 Mbit/s PPI .

• E1 (Connection Termination Point)The E1-CTP represents the non–intrusive monitoring of incoming 2 Mbit/s PPI. TheMon.(Monitoring) label indicates that is possible to enable the CRC4 control signal.

• S1 (Connection Termination Point)The S1-CTP represents the non–intrusive monitoring of outgoing 2 Mbit/s PPI . TheMon.(Monitoring) label indicates that is possible to enable the CRC4 control signal.

Page 306: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

258

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– TTPs on SDH level

On SDH level (see Figure 193. ) a distinction is made between the following TTPs:

• ES (Electrical Section TTP)An ESTTP displays the physical characteristics of a port with electrical access (level and codemonitoring and conversion).

• OS (Optical Section TTP)An OSTTP displays the physical characteristics of a port with optical access (level and codemonitoring and conversion).

• RST (Regenerator Section TTP)An RSTTP displays the creation and/or termination of an RSOH (Regenerator SectionOverhead), i.e., rows 1 to 3 of the first 9xN columns of an STM-N frame.

• MST (Multiplexer Section TTP)An MSTTP displays the creation and/or termination of an MSOH (Multiplexer SectionOverhead), i.e., rows 5 to 9 of the first 9xN columns of an STM-N frame.

• VC-4 (Trail Termination Point)A VC-4 TTP represents both the creation and termination of a VC-4 path.

– TTPs on PDH levelOn PDH level (see Figure 194. ) a distinction is made between the following TTPs:

• PPI (Trail Termination Point)On the PDH side, an PPITTP corresponds to the ESTTP of the synchronous side. Dependingon the type, it can either display the characteristics of a 140 Mbit/s, a 45MBit/s, a 34 Mbit/s ora 2 Mbit/s port.

• E4 (Trail Termination Point)The E4-TTP represents the creation and/or termination of a 140 Mbit/s connection.

• E3 (Trail Termination Point)The E3-TTP represents the creation and/or termination of a 34 Mbit/s connection.

• E2 (Trail Termination Point)The E2-TTP represents the creation and/or termination of an 8 Mbit/s connection.

• VC-4 (Trail Termination Point)A VC-4 TTP represents both the creation and termination of a VC-4 path.

• VC-3 (Trail Termination Point)A VC-3 TTP represents both the creation and termination of a VC-3 path.

• VC-12 (Trail Termination Point)A VC-12 TTP represents both the creation and termination of a VC-12 path.

– MSP definitionTransmit side, the MSNP (AU4–CTP) input enters two different MSNP/MSN (unProtected CTP)sources and then the MSN–TTP working and protection sources (to insert the K1–K2 bytes) are sentto the own SPI interfaces. Receive side, the working and protection MSN/MSNP outputs (AU4–CTP)enter in the switching selector. The MSNP–TTP terminates the selected signal and checks the SSFand the MSP protocol failure.

Page 307: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

259

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

!����"#����

$����

�������� %�&�����

��'(

���(����

��')

���)����

���*)����

+����

��'( ��'(

��')

��')��')��')

��') ��')

���*)�������*)����

Figure 193. SDH Transport Level Diagram

Page 308: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

260

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

!�����

%�������

!����� !(����

!)����

%��(����!(����

!*����

%��*)����

!)����

!*����

%��*)����

%��*)����

!*����

�������������� ��

*�,�+���"� )�+���"�

��-���

(��+���"�

%��(����

�.�+ ��"�

!()&��� !(*&���

Figure 194. PDH Transport Level Diagram

Page 309: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

261

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.1.4 Mapping Tables: TP Names

The TP names on the 1660SM reflect the software model the user interface is based on. Therefore theydiffer from the TP names given in the ITU-T recommendations. The following tables list the TP namesmapping conventions in the “Transmission” View.

Table 6. PDH TPs

����� �� ��� �� � ��

������ �

�� ��� ����

�� ��� �

�� ��� ����

�� ��� �

�� ��� ����

�� ��� �

�� ��� ����

�� ��� �� ��

�� ��� ��� �������

� ��� ��� �������

�� ��� ��� �������

���� ��� ���

��� ��� ��

����� ��� ����

Table 7. SDH TPs

����� �� ��� �� � ��

����� ���

����� ��

����� ���

���� ��

�� ��

���� ��� ��������

������� ��� �������

���� ��� ���

���� ��!

����� ��!�

��� ��� ��

���� ��� ���

����� ��� ����

Page 310: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

262

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.1.5 Cross-Connection Types

A cross-connection represents the logical connection between the input and output of the matrix, calledthe matrix port.

The matrix only receives and transmits signals in GTI format. The Generic Transport Interface GTI,Alcatel’s standardized signal format for internal interfaces, is similar to the STM-1 format. The incomingsignals are mapped or converted to GTI format on the plesiochronous and synchronous I/O boards. Thisframe is based on the STM-1 frame specified by ITU-T Recommendation G.707. It enables the transportof all signals in the US hierarchy and ETSI hierarchy levels 1 to 4 (1.5 Mbit/s to 140 Mbit/s) mapped toVirtual Containers (VCs) (see Figure 191. ).

The VCs are sent from the I/O boards to both copies of the Matrix (A and B) via the GTI. The matrixperforms the cross-connection on the VC-4, VC-3, VC-2 or VC-12 level and transfers the VCs to therelevant I/O boards via GTI. The configuration of both matrix copies is always identical. On the I/O boards,one GTI signal is selected from Copy A or Copy B, based on quality.

The NE supports unidirectional, bidirectional and broadcast connections unprotected as well as protected.

15.1.5.1 Unidirectional Connection

Information is transmitted exclusively from the input port to the output port (point-to-point); there is norouting in reverse direction.

ÀÀÀÀÀÀÀÀÀÀÀÀ

ÈÈÈÈÈÈÈÈÈÈÈÈ

input TP output TP

Figure 195. Unidirectional Connection

15.1.5.2 Bidirectional Connection

Information is transmitted between input port and output port in both directions (point-to-point).

ÀÀÀÀÀÀÀÀ

ÈÈÈÈÈÈÈÈ

input TP output TP

Figure 196. Bidirectional Connection

Page 311: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

263

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.1.5.3 Broadcast Connection (Multi-leg / Multipoint)

In contrast to a cross-connection between just two points (point-to-point), one source and one sink, abroadcast connection consist of one source and several sinks, different ‘legs’ that share the same sourceTP.

In the example below, information is broadcast from one input to outputs A, B and C on three legs.

ÀÀÀÀÀÀÀÀÀÀÀÀ

ÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ

input TPÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ

output A

output B

output C

leg 1

leg 2

leg 3

Figure 197. Example of Broadcast Connection with Three Legs

A warning box indicates when the resources available for broadcast connections are exhausted.

N.B. Non-intrusive MonitoringAdding a protection leg to a unidirectional cross-connection offers the ability to performnon-intrusive monitoring on this cross-connection. No errors are introduced to the originalcross-connection with applying or removing the protection leg.

Page 312: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

264

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.1.6 Cross-Connection Protection

15.1.6.1 Protected Unidirectional Connection

A unidirectional connection is routed from Input A to the Output (primary route). In the case of a failure,the system automatically switches to the protection path from protection Input B to the Output. This secondconnection is permanently kept in hot standby operation (see Figure 198. ).

in case of

ÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ

ÈÈÈÈÈÈÈÈÈÈÈÈprot.

input B

input A

output TP

failure

Figure 198. Protected Unidirectional Connection

15.1.6.2 Protected Bidirectional Connection

A bidirectional connection is routed from Input A to the Output C (primary route). Input A (input protected– see Figure 199. ) can be protected:

ÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ

ÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ

A

B

C

in case of failure

Figure 199. Bidirectional Connection – Input Protected

N.B. By means of this connection are created links with SNCP protection.

Page 313: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

265

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.1.6.3 Protected Broadcast Connection

The protected broadcast is realized as a set of independent, protected, unidirectional connections usingthe same pair of input termination points, as illustrated in Figure 200. Each protection can be forced,locked out or switched independently. Therefore, if a failure occurs at a certain input, it is possible that onlysome of the protections of the protected broadcast actually switch to the protection input.

����������

ÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ

ÈÈÈÈÈÈÈÈÈÈÈÈ����/

�����

����� �

������

�������

ÈÈÈÈÈÈÈÈÈÈÈÈ

������ �

ÈÈÈÈÈÈÈÈÈÈÈÈ

������ �

��� �

��� �

��� �

Figure 200. Protected Broadcast

Figure 200. shows a broadcast connection from input A to outputs A, B and C. Leg 2 and 3 are protectedvia input B, whereas leg 1 is not protected.

In current release only one out of N legs can be protected.

15.1.6.4 Drop and Continue Connection

A Drop and Continue connection is a composed by: (see Figure 201. )

• a unidirectional connection routed from Input A to the Output C and also to Input protecting B.

• a unidirectional connection from Input protecting B to Output C.

• a unidirectional connection from Output C to Input A.

Output C is protected; when receive from Input main the connection is defined normal, when receivefrom Input Protecting main the connection is defined inverse.

All the connections are created in a single step of configuration.

ÈÈÈÈÈÈÈÈÈÈÈÈ

ÈÈÈÈÈÈÈÈÈÈÈÈ

ÈÈÈÈÈÈÈÈÈÈÈÈ

A

Input Pro

Output

t. input

B

C

Figure 201. Drop and Continue – Normal

Page 314: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

266

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.2 Operative Sequence to execute Cross-Connections

This paragraphs list the complete procedure to realize some examples of cross-connection moving amongthe various menus.

The following main cases have been considered:

[1] High order signal cross connection (AU4s between SDH ports);

[2] High order concatenated signal cross connection (AU4–xc between SDH ports)

[3] Low order signal cross connection (TU12 cross connected with VC–12; ports involved: SDH andPDH )

[4] 4XANY TPs cross connection (ports involved: 4XANY and SDH)

[5] ISA board TPs cross connection (ports involved:ISA, SDH or PDH)

[1] Procedure for high order signal (AU4)

In the following example an AU4 will be cross connected with another AU4; the P4S1N board has beentaken like reference board.

– In the subrack view click twice on the SDH port; the” board view” will be opened

– Click twice on the daughter board icon; the daughter view will be opened.

– Click twice on the SDH port icon present in the daughter view. the port view will be opened with allthe relevant TPs (SPI, RST, MST, MSP and AU4).

– Select the AU4 TP and then choose the Port –>Cross Connection –> Create Cross Connection optionof the menu bar; a new window called ”Main Cross Connection” is opened.

• Select the correct value in the fields ”Type” and ”Protection”

• The “Input field” is automatically filled in

• Click on ”Choose” relevant to the ”Output” field; a new window called ”Search for CrossConnection Output” is opened.

• On the ”Equipment” field select the Board (in our example is P4S1N), in the ”Termination Points”field select the AU4

– Click on ”OK”; the ”Search for Cross Connection Output” window is closed.

– Repeat the same procedure as obove described for the ”Prot. Input” field for protected connections

– Click on ”OK” in the ”Main Cross Connection” window to terminate the creation.

– To check the presence of the new cross– connection select the Port –>Cross Connection –> CrossConnection Management option of the menu bar; a new window called ”Coss connectionManagement” will be opened

• Click on the “Search” button; all the cross connected Tp’s will be displayed in the “CrosConnection in list” field.

Page 315: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

267

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

[2] Procedure for AU4 concatenated (AU4–xC)

N.B. Before to create an AU4 concatenated cross–connection is necessary to define that the AU4son a STM–4 or STM–16 (the last only for 1660SM) board are concatenated as explained in para11.6 on page 148.

– In the subrack view click twice on the STM_N SDH port; the” board view” will be opened

– Click twice on the SDH port icon present in the board view. the port view will be opened with all therelevant TPs (SPI, RST, MST, MSP and AU4–xC).

– Select the AU4–xC (with 4� X �16) TP and then choose the Port –>Cross Connection –> CreateCross Connection option of the menu bar; a new window called ”Main Cross Connection” is opened.

• Select the correct value in the fields ”Type” and ”Protection”

• The “Input field” is automatically filled in

• Click on ”Choose” relevant to the ”Output” field; a new window called ”Search for CrossConnection Output” is opened.

• On the ”Equipment” field select the STM–N Board , in the ”Termination Points” field select theAU4–xC (with 4� X �16) (syntax example: r01sr1sl24/port#01–#01AU4P–4c ).

– Click on ”OK”; the ”Search for Cross Connection Output” window is closed.

– Repeat the same procedure as obove described for the ”Prot. Input” field for protected connections

– Click on ”OK” in the ”Main Cross Connection” window to terminate the creation.

– To check the presence of the new cross– connection select the Port –>Cross Connection –> CrossConnection Management option of the menu bar; a new window called ”Coss connectionManagement” will be opened

• Click on the “Search” button; all the cross connected Tp will be displayed in the “CrosConnection in list” field.

[3] Procedure for low order signal (example TU12)

In the following example a VC–12 will be cross connected with a TU–12; the boards P4S1N and A21E1has been taken like reference board for this example.

Note: the P4S1N STM–1 port payload must be structure as TU–12

– In the subrack view select Configuration –> Cross Connection Management the” Cross ConnectionManagement” window will be opened.

– Click on the Create button; a new window called ”Main Cross Connection” is opened.

• Select the correct value in the fields ”Type” and ”Protection”

• Click on ”Choose” relevant to the ”Input” field; a new window called ”Search for CrossConnection Input” is opened.

• On the ”Equipment” field select the Equipment Subrack (SR60M for 1660SM), in the “TP SeachCriteria” field select the TU12&VC12, then click on search.

• In the Termination Point Field select the TU12 to be connected and subsequently click on OKbutton; the ”Search for Cross Connection Input” window will be closed.

Page 316: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

268

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

• Click on ”Choose” relevant to the ”Output” field and repeat the same sequence as abovedescribed for the input point but instead of TU12 select now the VC12 to be connected in theTermination Point Field; click on OK button AND the ”Search for Cross Connection Output”window will be closed.

– Select the VC–12 TP and then select the Port –>Cross Connection –> Create Cross Connectionoption of the menu bar; a new window called ”Main Cross Connection” is opened.

• Select the correct value in the fields ”Type” and ”Protection”

• The “Input field” is automatically filled in

• Click on ”Choose” relevant to the ”Output” field; a new window called ”Search for CrossConnection Output” is opened.

– Repeat the same on the ”Prot. Input” field for protected connections by selecting the TU12 involvedin the protection.

– Click on ”OK” in the ”Main Cross Connection” window to terminate the creation.

– To check the presence of the new cross– connection select the Port –>Cross Connection –> CrossConnection Management option of the menu bar; a new window called ”Coss connectionManagement” will be opened

• Click on the “Search” button; all the cross connected Tp will be displayed in the “CrosConnection in list” field.

[4] 4XANY TPs cross connection

Note: before to create a cross connection the following step must be executed:

• configure the 4xANY board with the Equipment –> Set menu• configure the 4xANY MODULES with the Equipment –> Set menu and choose the traffic type

that must be supported by the module (e.g. FICON, FDDI etc.); after having selected the traffictype, automatically a number of TPs (VC–4) are generated for this port and can be viewed inthe port view. All the TPs must be used when the cross– connection will be created.For details on 4xANY board refer to the Technical Handbook.

– In the subrack view click twice on the 4xANY board; the” board view” will be opened .

– Click twice on the module to be used; the daughter view will be opened

– Click twice on the daughter board icon; the port view will be opened with all the relevant TPs.

In the following will be explained how to connect one TpP of the 4XANY; repeat the same sequence forall the TPs that has been generated when the traffic type has been defined.

– Select the VC–4 TP and then choose the Port –>Cross Connection –> Create Cross Connectionoption of the menu bar; a new window called ”Main Cross Connection” is opened.

• Select the correct value in the fields ”Type” and ”Protection”

• The “Input field” is automatically filled in

• Click on ”Choose” relevant to the ”Output” field; a new window called ”Search for CrossConnection Output” is opened.

Page 317: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

269

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

• On the ”Equipment” field select the Board to be used for the connection with the 4XANY board(for example S4.1N), in the ”Termination Points” field select the AU4

– Click on ”OK”; the ”Search for Cross Connection Output” window is closed.

– Click on ”OK” in the ”Main Cross Connection” window to terminate the creation.

– repeat the same procedure for all the VC–4 generated for the specific traffic type associated to the4xANY module.

– To check the presence of the new cross–connection select the Port –>Cross Connection –> CrossConnection Management option of the menu bar; a new window called ”Coss connectionManagement” will be opened

• Click on the “Search” button; all the cross connected Tp will be displayed in the “CrosConnection in list” field.

[5] ISA board TPs cross connection

Note: before to create a cross connection the following step must be executed:

• configure the ISA board with the Equipment –> Set menu• define the TP that must be created on the ISA board by selecting the Configuration –> ISA Port

Configuration menu (refer to Chapter 20 for details)

– The ISA board TP cross– connection is similar to that described for the 4xANY board so refer to point[4] .

Page 318: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

270

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.3 Cross-Connections management

A list of cross-connections can be displayed in the Cross-Connection Management dialog (seeFigure 204. on page 275). The dialog can be accessed via the Transmission or Port view or viaConfiguration menu as indicated in Figure 202.

Transmission view is presented with the View → Transmission pull down menu.

Port view is presented with the View → Equipment pull down menu, then clicking on the presentedobjects with the sequence board>port.

Figure 202. Cross connection management cascade menu

Page 319: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

271

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The Cross-Connection Management dialog is initially empty (see Figure 203. on page 273).

A list of cross-connections is displayed in the Cross-Connection Management dialog after selecting theSearch command.

There are two possibilities of displaying a list of cross-connections:

– do not enter any search criteria and press the Search button to display a list of all existingcross-connections,

– enter Search Criteria (one or more) and then press the Search button to display a selection ofcross-connections. Set Ignore for attributes not to be used as filtering criteria.

Use button Cancel Search to cancel an active search request or close the dialog.

Page 320: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

272

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.3.1 Search Criteria

– Name (not supported in current release)

Number of the cross–connection (automatically assigned)

– ACD (not supported in current release)

Enter the Access Control Domain of the relevant cross-connections: E= connection made with1353SH, M= connection made with 1354RM, empty= connection made with CT.This filter option can only be used, if at least one ACD is defined on the NE and one or morecross-connections are assigned to this ACD(s).

– TypeSelect the connection type:

• Unidirectional• Bidirectional• Multipoint• Drop&Continue

– ProtectionSelect protection functionality:

• Protected• Not protected

– TP ClassSelect one of the TP types involved in the requested cross-connection.

– StateSelect the connection state:• Activated• Deactivated (not operative in current release, the connection state is always Activated)

– Prot. StateSelect the protection state (for more detailed information, refer to Chapter 9.5):• Forced to Input• Forced to Protecting• Manual Switch to Input• Manual Switch to Protecting• Auto. Switch to Input• Auto. Switch to Protecting• Lockout• Normal I• Normal P

– TP ID PrefixEnter the TP type and physical location of the port, or only the physical location at least down to boardlevel, according to the following format:r<rack#>s<subr.#>b<board#>/port#<port#>-TP (see Figure 204. on page 275)The # within brackets identifies a number.

Page 321: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

273

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 203. Cross-Connection Management Dialog (Initial State)

Page 322: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

274

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.3.2 Cross-Connection List

After a successful search, a read only list of cross-connections matching the search criteria appears(see Figure 204. ). The number of matching cross-connections is displayed in the upper left corner of thelist. The list contains information concerning the following parameters for each cross-connection:

– Prot. Statedetailed switching information in the format:<protection state> <traffic ind> (<location>:<signal state>–<switch status>,[<location>:<signal state>–<switch status>])

• <protection state>Normal, Auto, Lockout, Forced or Manual.

• <traffic ind>indicates the location of current traffic:P (Protecting input) or I (Input).

• <location>indicates the location of the errored signal:P (Protecting input) or I (Input)

• <signal state>indicates the signal state: SD (Signal Degrade) or SF (Signal Failure)

• <switch status>status of the switch:c (completed) or p (pending)

Example:Auto I (P:SD-c)There has been an Automatic switch from the protecting input to the Input where the traffic iscurrently located. The reason for the automatic switch was Signal Degrade in the Protecting input.The switch was completed.

– SNCP

Protection type indication I ( Inherently monitored Sub–Netwok Protection) or N (Non–intrusivelySub_Network Connection Protection)

– Stateconnection state indicating whether cross-connection is A(ctivated) or D(eactivated)

– Dir.Direction-related connection type:uni(directional), bi(directional), mp (multipoint), DC_N (Drop & Continue Normal) or DC_I (Drop &Continue Inverse)

– Inputsignal source; contains the TP type and physical location of the port according to the format<rack#>–<subr.#>–<board#>–<port#>,<port#>#TP (see Figure 204. on page 275)The # within brackets identifies a number.

– Protecting Input

Page 323: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

275

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

protecting source (for protected cross-connections only); contains the TP type and physical locationof the port according to the formatr<rack#>s<subr.#>b<board#>/port#<port#>-TP (see Figure 204. on page 275)The # within brackets identifies a number.

– Outputsignal destinationfor point-to-point cross-connections, the TP ID of the destination is specified according to the formatr<rack#>s<subr.#>b<board#>/port#<port#>-TP ; for multi-leg cross-connections, the string“multiple Legs” appears instead.

At the bottom of the dialog is a range of buttons to start actions on the listed cross-connections. Beforestarting any action apart from creation or printing, mark at least one cross-connection.

To mark several cross-connections (multi-select) that are listed in succession, select the firstcross-connection of a block with a mouse click and the last one with a mouse click while pressing the<Shift> key.

Or, mark a number of individual cross-connections by clicking the mouse button while pressing the<Control> key.

Deselect cross-connections by clicking on the respective row while simultaneously pressing the <Control>key. To deselect a number of cross-connections at a time, press the <Shift> key and hold it down whilemoving the mouse pointer to the last entry.

All actions that may affect traffic must be confirmed. A confirmation dialog pops up in this case and theuser has to confirm the requested action.

Figure 204. Cross-Connection Management Dialog (After Search)

Page 324: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

276

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.3.3 Actions available

The following actions are available:

– Create a cross–connection (see chapter 15.4 on page 277)

The Main Cross-Connection dialog (see Figure 208. on page 284) is opened.

– Modify a Cross-Connection (see chapter 15.4 on page 277)Available if just one cross-connection is selected from the list. The Main Cross-Connection dialog(see Figure 208. on page 284) is opened.

– Activate a Cross-Connection (see chapter 15.5 on page 292)Available if at least one cross-connection is selected from the list. Not operative in current release.

– Deactivate a Cross-Connection (see chapter 15.5 on page 292)Available if at least one cross-connection is selected from the list. Not operative in current release.

– Delete a Cross-Connection (see chapter 15.5 on page 292)Available if at least one cross-connection is selected from the list.

– Split a Cross-Connection (see paragraph 15.6.1 on page 295)Available if at least one bidirectional cross connection is selected from the list.

– Join Cross-Connections (see paragraph 15.6.2 on page 295)Available if two cross connections are selected.

– Protection Switching (see chapter 15.7 on page 296)Available if exactly one protected cross-connection is selected from the list. The Protection Actionsdialog is opened.

– Print (see chapter 15.8 on page 298)Prints the filtered list of cross-connections.

The dialog has to be closed explicitly.

Page 325: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

277

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.4 Create/Modify Cross-Connections

Creation and modification of cross-connections are performed in the Main Cross-Connection dialog. Thedialog can be accessed via the Transmission or Port view as for the following menus example or by usingthe Create or Modify buttons (chapter 15.3.3 on page 276) in the Cross-Connection Managementdialog (see Figure 203. on page 273).

The dialog box of Figure 208. on page 284 is presented ( “Main Cross Connection” view).

Page 326: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

278

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

To prevent operation faults, the system is designed according to the following guidelines:

– All operations that may affect traffic must be confirmed. The subsystem provides a confirmationdialog box before the operation can be executed.

– If the window displays an existing cross-connection, the OK button is insensitive when thiscross-connection is assigned to NML or it is not assigned to the user profile.

– If the window is used to create a new cross-connection, the system verifies that the relevant TPs canbe used (not assigned to NML and assigned to the user profile) after the OK button is pressed. If aspecified TP is not permitted, the corresponding message box appears.

15.4.1 Cross-Connection Parameters

The “Main Cross Connection” view of Figure 208. on page 284 permits to create the cross connections.

A cross-connection is defined through a set of parameters which depend on the connection and protectiontype. Only those parameters which are permitted within the current context can be accessed. All othersare disabled (faded gray).

To create a cross-connection, one or more of those parameters must be defined according to thecross-connection type. Table 8. gives an overview about the optional and mandatory input parameters forthe various cross-connection types. Activate the relevant entry boxes first of all by clicking on them withthe mouse.

Configurable Parameters

– TypeSelect the connection type:• Unidirectional• Bidirectional• Drop&Continue

– D&C TopologySelect the direction for Drop&Continue:• Normal• Inverse

– ProtectionDefine protection state:• Protected• Not Protected

– Prot. Criteria (only available for protected connections)

Clicking on the Prot. Criteria button, Figure 205. for the Protection Criteria dialog is opened, wherethe user can display and configure the SNCP Type Protection. No protection criteria for automaticprotection switching can be configured.

The following SNCP Type are available:

• SNCP–I (Inherently monitored Sub–Network Connection Protection)

• SNCP–N (Non–intrusively monitored Sub–Network Connection Protection)

• SNCP–S (Sub–layer Sub–Network Connection Protection) (Not operative in current release)

Page 327: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

279

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 205. Protection Criteria

– Revertive (available only for protected connections)Select whether protection is to be revertive or not.In Revertive mode, a protected service is switched back to its initial, protected element when the faulthas been eliminated.When Revertive mode is active, the Wait To Restore protection period prevents several protectionswitches being initiated as a result of an intermittent failure. The protected element must be error-freeduring this defined period of time before a protected service is switched back to it.In the current release the Wait To Restore time period is fixed to 5 minutes.In Non-revertive mode, switchover to the protecting element is maintained even after the fault hasbeen eliminated.

– HOT (available only for protected connections)To enter the Hold Off Time expressed in msec. with a range from 0 to 10.000.HOT is the time between declaration of Signal Degrade or Signal Fail, and the initialization of theprotection switching algorithm.

– InputTo enter the input TP, click the relevant Choose button and select the TP in the TP Search dialog(see Figure 162. on page 218). Otherwise, select the input field and enter the name of the TP directly.

– Prot. InputTo enter the protecting TP, click the relevant Choose button and select the TP in the TP Searchdialog. Otherwise, select the input field and enter the name of the TP directly.

– OutputIt is possible to enter one or more output TPs.To enter one output TP, click the relevant Choose button and select the TP in the TP Search dialog.Otherwise, select the input field and enter the name of the TP directly.To enter more than one output TP and create a broadcast connection, proceed as describedpreviously and press button Add afterwards. The previously chosen TP is then moved to the list boxlocated below. Click the Choose button and select the next TP in the TP Search dialog. Otherwise,select the input field and enter the name of the TP directly. Repeat this procedure for each destinationTP. A list of all the selected output TPs is displayed in the list box located below it.To delete a leg from the list, select the TP in the list box and click on the Delete Leg button.

Page 328: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

280

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

N.B. Non-intrusive MonitoringAdding a protection leg to a unidirectional cross-connection offers the ability to performnon-intrusive monitoring on this cross-connection. No errors are introduced to the originalcross-connection with applying or removing the protection leg.

Table 8. Optional and Mandatory Configurable Parameters for Cross-Connection Creation

���� � ������

������������ ������������� � ����� ����������

��� �� �� ����� ����������

������������

��������� ������������

���������

���� ������������"����������� ������������

12� �������� ������"��3���� & &

��������� ��� ������� ������� ��� ������� �������

�����������������

& ����&-

����&�

& ����&-

����&�

4#� & 5 & 5

������� & & & &

$�3����3� & 5 & &

-���� ��� �� ��� �� ��� �� ��� ��

��������� -���� & ��� �� & ��� ��

#����� ��� �� ��� �� ��� �� �������

��� �� �������

& ��� �3�������5 ������������ ��������

Page 329: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

281

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Non-configurable Parameters

– CC Topology

The topology of the cross-connection is indicated via two icons. The left-hand icon displays thecurrent topology and the right one displays a view of the topology following confirmation of the currentmodifications.

In addition, the color of an icon indicates the connection state of the cross-connection:

green –> active

brown –> inactive

The icon is set according to the entries made in Type and Protection:

TPs not cross-connected

Unidirectional, not protected

Bidirectional, not protected

Unidirectional, protected

Bidirectional, protected

Broadcast, not protected

Broadcast with one protected leg

Drop & Continue normal

Page 330: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

282

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Drop & Continue inverse

Loopback connection:unidirectional, same input and output TP

Figure 206. Cross-Connection Icons

current state:TPs are not connected

state after creation:unidirectional, non-protected cross-connection

Example:

Figure 207. Creation of a Unidirectional, Non-Protected Cross-Connection

Page 331: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

283

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.4.2 Create a Cross-Connection

This chapter lists the steps the user has to take to create a cross-connection using The “Main CrossConnection” view of Figure 208. on page 284.

For a detailed description of the single parameters, refer to the previous para. 15.4.1 on page 278.

For information on cross-connection types, refer to para. 15.1.5 on page 262.

N.B. After creation of a cross-connection, the cross-connection list in the Cross ConnectionManagement dialog is not automatically updated. Use button Search in this dialog to updatethe list.

Create a Point-to-Point Cross-Connection (uni- or bidirectional)

1 ) Select the cross-connection Type.

2 ) Select the Protection state.

3 ) Select or type in the Input TP.

To enter the TP, click the Choose button and select the TP in the Search for Cross ConnectionInput dialog (see Figure 209. ), or select the input field and enter the name of the TP directly.

The Search for Cross Connection Input dialog offers the possibility to list TPs according todifferent filter criteria. E.g. to obtain a list of all not connected AU-4 TPs of a rack, first select therack in the left list box, then select the filter criteria ConnectionState “not connected” and Class“AU-4” and click on button Search. The matching TPs are listed in the right listbox. Select theinput TPs in the list and confirm with Ok.

For a more detailed description on the Search for Cross Connection dialog see para. 14.5.1on page 217.

4 ) Select or type in the Output TP as described in Step 3 ).

The following steps only apply to protected cross-connections:

5 ) Select or type in the Protecting Input (Prot. Input) TP as described in Step 3 ).

6 ) Configure the Revertive mode.

7 ) Configure the Protection Criteria (Prot. Criteria)

8 ) Configure the HOT (Hold Off TIme)

Press the button Ok to confirm the creation.

Page 332: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

284

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 208. Create a Bidirectional Protected Cross-Connection (example)

Page 333: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

285

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Create a Broadcast Connection

1 ) Select the cross-connection Type “unidirectional”

2 ) Select the Protection state.

3 ) Select or type in the Input TP.

To enter the TP, click the Choose button and select the TP in the Search for Cross ConnectionInput dialog (see Figure 209. ) or select the input field and enter the name of the TP directly.

This dialog offers the possibility to list TPs according to different filter criteria. E.g. to obtain alist of all TU12 TPs of a board, first select the board in the left list box, then select the filter criteriaConnection State “Ignore” and Class “TU12” and click on button Search TPs. The matchingTPs are listed in the right listbox (see Figure 209. ). Select the input TPs in the list and confirmwith Ok.

For a more detailed description on the Search for Cross Connection dialog see para. 14.5.1on page 217.

4 ) Select or type in the Output TPs as described in Step 3 )

Press the button Add Leg in the Main Cross Connection dialog and all output TPs are displayedin the list box under the Output field (Figure 210. on page 287).

To delete a leg from the list, select the TP in the list box and click on the Delete Leg button.

The following steps only apply to protected broadcast connections:

5 ) Select or type in the Protecting input TP. Note that each single protected leg of the broadcasthas to be assigned to the same protecting input.

Proceed as described in Step 3 ). Afterwards, select the protected output TP in the output list boxand click button Protect Leg. The leg is then marked as “protected” in the list box. Repeat thisprocedure for each protected output TP (only one protected leg is supported in current release).

To unprotect a leg from the list, select the protected TP in the list box and click on the Unprotect Legbutton.

Examples are in Figure 210. and Figure 211.

6 ) Configure the Revertive mode.

7 ) Configure the Protection Criteria (Prot. Criteria)

8 ) Configure the HOT (Hold Off TIme)

Press the button Ok to confirm creation.

Page 334: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

286

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 209. Search for Cross-Connection Output (example)

Page 335: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

287

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 210. Create an Unprotected Broadcast Cross-Connection (example)

Page 336: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

288

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 211. Create a Protected Broadcast Cross-Connection (example)

Page 337: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

289

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.4.3 Modify a Cross-Connection

When modifying a cross-connection, note that some of the transformations involved may affect traffic(because the system may have to destroy and re-create the cross-connection to perform the necessarytransformation). As mentioned at the beginning of this chapter, the user is required to confirm operationsaffecting traffic, i.e. a confirmation window warns the user.

Within the Main Cross Connection dialog, modification of a cross-connection is restricted to theprotection state and the parameters required by the protection. Refer to Table 9. for an overview of theaccessible parameter when the protection state has been changed from “not protected” to “protected” andvice versa. For a description of the parameters, please refer to the previous para. 15.4.1 on page 278.

To modify a cross connection select one from the connection list of Figure 204. on page 275. and then clickon the Modify button.

N.B. After modification of a cross-connection, the cross-connection list in the Cross ConnectionManagement dialog is not automatically updated. Use button Search in this dialog to updatethe list.

Table 9. Modifiable Parameters

��� � � ������ ������� ����

��� �������� ����������

�������� �� �����������

���� & &

12� �������� ������"��3����

������"��3����

��������� ������� ��� �������

��������� �������� 5 &

��������� & 5

������� 5 &

4#� 5 &

$�3����3� 5 &

-���� 5 5

��������� -���� 5 &

#����� 5 5

& ��� ��������5 ��������

Page 338: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

290

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The following few facts should be taken into consideration when modifying connections.

– Unprotect a protected cross-connection (see Figure 212. ):

When a protected cross-connection is being unprotected (protection changed to “not protected”), thedialog displays the additional option button Unprotected.

It offers the choice of whether to keep the protected input TP (Input) or the protecting input TP (Prot.Input) as the only signal source of the new unprotected cross-connection. Ensure that the active TPis selected (i.e. check the protection state in the Cross-Connection Management dialog).

An example is in the following Figure 212.

In addition, a question box appears, asking the user to confirm the unprotect action.

Figure 212. Unprotect a Bidirectional Cross-Connection (example)

Page 339: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

291

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Protect an unprotected cross-connection:

When an unprotected cross-connection is being protected, the Prot. Input button is available toselect the protection input connection to insert.

An example is in the following Figure 213.

Protection principle are given in para. 15.1.6 on page 264.

Figure 213. Protect one Leg of a Broadcast Connection (example)

Page 340: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

292

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.5 Activate/Deactivate/Delete Cross-Connections

15.5.1 Activate a Cross-Connection

Not supported in current release.

The Cross Connection Management dialog provides the possibility of displaying a selection of existingcross-connections (see Chapter 15.3 on page 270). The connection state (Act = A or D) is indicated in thisconnection list.

To activate a cross-connection, select one from the connection list (see Figure 204. ) and then click on theActivate button to initiate the process. A confirmation box appears in which to confirm the state changerequest. The connection in the list is automatically updated to indicate the new connection state (Act = A).

If the set of cross-connections selected from the list includes both activated and deactivatedcross-connections, clicking the Activate button only initiates actions on the deactivatedcross-connections which were selected.

15.5.2 Deactivate a Cross-Connection

Not supported in current release.

After creation, a cross-connection is automatically in an active state. To deactivate a cross-connection,select one from the connection list (see Figure 204. ) and then click on the Deactivate button to initiatethe process. A confirmation box appears in which to confirm the state change request. The connectionin the list is automatically updated to indicate the new connection state (Act = D).

If the set of cross-connections selected from the list includes both activated and deactivatedcross-connections, clicking the Deactivate button only initiates actions on the activatedcross-connections which were selected.

15.5.3 Delete a Cross-Connection

Only deactivated cross-connections should be deleted. However, deletion of active cross-connections ispossible.

NOTE: the “Delete cross–connection” action is not possible in the case that is stillexisting any operation/connection/termination on the underlying supported signals, such as:• Performance Monitoring on lower or higher TPs• POM / HPOM operations• Lower order Connections• Higher order Connections• Lower/Higher order Path Terminations• Loop–backs• LAN/LAPD (and any comm/routing channel)• Auxiliary channelsThus the deletion of every active operation/connection/termination is necessary, in the same order asabove listed, before the deletion of a cross–connection.

To delete a cross-connection, select the corresponding connection from the list and click on the Deletebutton. To prevent operation errors, the user must confirm the deletion request.

The deleted cross-connection automatically disappears from the connection list when the operation issuccessful.

Page 341: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

293

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.6 Split and Join Cross-Connections

15.6.1 Split a Cross-Connection

Precondition

Only bidirectional cross-connections can be split.

Split

Select one or more bidirectional cross connections from the list in the Cross Connection Managementdialog and press Split. The cross-connections are split without further confirmation from the user.

The original cross connection(s) disappear from the list in the Cross Connection Management dialogafter a successful action. The user has to press Search to see the new cross connections.

Depending on the protection state of the original cross-connection, the split action has the following effect:

a ) Unprotected Cross-Connection

An unprotected bidirectional cross-connection is split into two unidirectional cross-connections withthe input TP in one of them being the output in the other and vice versa (see Figure 214. ).

The new cross connection has the same name and activation status as the old bidirectional one.

ÀÀÀÀÀÀÀÀÀ

ÀÀÀÀÀÀÀÀÀ

ÀÀÀÀÀÀÀÀÀ

ÀÀÀÀÀÀÀÀÀ

� ÀÀÀÀÀÀÀÀÀ

ÀÀÀÀÀÀÀÀÀÀÀÀ

�����6���7��� *8

Figure 214. Split/Join Unprotected Bidirectional Cross-Connection

Page 342: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

294

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

b ) Protected Cross-Connection

Splitting a protected connection results in one protected unidirectional cross-connection and onebroadcast with two legs. The input of the original cross-connection is one of the legs in the broadcast.The other leg in the broadcast is the protecting input. The input of the broadcast is the output of theoriginal protected cross-connection.

ÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ

ÈÈÈÈÈÈÈÈÈ

ÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ

ÈÈÈÈÈÈÈÈÈ

ÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ

ÈÈÈÈÈÈÈÈÈ

�����

������� ������������ ������������� ������� ��������

6���7��� )8

Figure 215. Split/Join to Protected Bidirectional Cross-Connection

Page 343: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

295

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.6.2 Join Two Cross-Connections

Precondition

Two cross-connections can be joined if they match the following characteristics:

– The connections are either

1 ) both unprotected, unidirectional and the input is the output of the other one, or

2 ) one of them is protected and unidirectional, and the other one a broadcast with two legs.Restriction: the input of the broadcast connection has to be the output of the protectedconnection and the legs of the broadcast match the input and the protection input of theunidirectional connection, also refer to Chapter Split a Cross-Connection, effect b).

– Both cross-connections have the same connection state (activated or deactivated).

– Both cross-connections have the operational state “enabled”, i.e. they are listed in black color in theCross Connection Management dialog.

Join

Select exactly two cross connections in the Cross Connection Management dialog and press the Joinbutton. The cross-connections are joined without further confirmation from the user.

The original cross connection(s) disappear from the list in the Cross Connection Management dialogafter a successful action. Press Search to see the new cross-connections in the list.

The result is either a bidirectional (case 1, see Figure 214. ) or a protected bidirectional (case 2, seeFigure 215. ) cross-connection.

If the original cross-connections have different names, the new name is a concatenation of the names ofboth of them.

Page 344: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

296

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.7 Protection Switching

The Protection Actions dialog is displayed after clicking on the Protection button in the CrossConnection Management dialog (see Figure 204. ).

Users can only switch protection on cross-connections belonging to them and not assigned to the NML.A second condition is that protection is enabled for the cross-connection concerned (protection parameteris set to “protected”).

The three protection actions Force, Lock Out and Manual Switch belong to different levels, wherebyLock has the highest priority and Manual Switch the lowest.

Note that a protection state can only be changed within the same or from a higher priority level, e.g. ForceTo Protecting can be reverted with Release but not with Manual Switch To Input.

Figure 216. Protection Actions Dialog

The dialog window enables the user to perform protection- related operations on protectedcross-connections. These are:

– Force to Input

The cross-connection is switched to the protected input regardless of signal quality. Automaticprotection is disabled.

– Force to Protecting (Input)

The cross-connection is switched to the protecting input regardless of signal quality. Automaticprotection is disabled.

– Release Force

Forced switching is disabled and automatic protection switching re-enabled.

Page 345: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

297

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Manual Switch to Input (not operative in current release)

The user can switch over to the protected input manually. Switching over is not executed if the signalquality on the protected path is worse than on the protecting path.

– Manual Switch to Protecting Input (not operative in current release)

The user can switch over to the protecting input manually. Switching over is not executed if the signalquality on the protecting path is worse than on the protected path.

– Release Manual Switch (not operative in current release)

A manual switch is disabled and automatic protection switching re-enabled.

– Lock Out to Invoke

The connection path is locked for protection switching, i.e. neither forced nor manual switching canbe performed.

– Release Lock

The protection lock is disabled.

N.B. All the operations listed are context-dependent and are enabled or disabled (“grayed”)accordingly.

After completion of protection switching, the list entry in the Cross Connection Management dialog isupdated automatically.

After clicking on an action button and completing the action initiated, the dialog disappears automatically.

Page 346: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

298

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.8 Print

This option is used to print the currently filtered cross-connection list and the related filter settings on thedefault printer or to a file in postscript or ASCII format (see Figure 217. and Figure 218. )

Figure 217. Select Printer

N.B. If no printer is installed, there is no error message displayed to indicate this.

Figure 218. Select Output Format

Page 347: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

299

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

15.9 Show Cross-Connected TPs

An overview of signal flow can be requested by means of a user action. The user can select a TP andinitiate the action Show Cross Connected TPs from the Transmission view.

The result is that all other TPs connected to the currently selected TP are displayed (see the example ofFigure 219. on page 300). A line indicates the connection .

This functionality should only be applied selectively (either for a single TP or selected group of TPs).Expanding and hiding TPs that are associated with the currently selected TP (e.g. show all TPs that areabove the TU12CTP) enables all the related TPs to be added to the view so that the complete signal flowcan be illustrated.

Page 348: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

300

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 219. Show Cross Connected VC4 of an AU4

Page 349: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

301

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

16 OVERHEAD MANAGEMENT

16.1 Introduction

All the descriptions in the following paragraphs are applicable only to 1650SMC and 1660SM.

The purpose of this set of dialogs is to handle the operations on the Overhead (OH) bytes of the NE.

The possible operations are:

• Overhead cross–connection

– Cross–connection between 2 or more OH bytes– Termination of an OH byte onto an auxiliary port or vocal channel– Total Pass–through of the MSOH bytes for some cards– Definition of the Phone Parameters

There is a TP associated to every OH byte and to every auxiliary port, so TP could be used instead ofOH bytes or auxiliary port, depending on the context.

Note for 1640FOX:

Two bytes of the SDH Overhead frame are accessible for auxiliary purposes, in V11 and RS232 format;the dedicated bytes are fixed and belong to the STM1#1 or STM4#1 (the module inserted in the highestposition of the CompactADM unit). The auxiliary services on STM1#2 or STM–4#2 are not available incurrent release, except just in case of 1+1 MSP STM–N line protection.

These bytes are E1 (for V11 signal) and F1 (for RS232). The auxiliary signals are available, at theback–side connector, as soon as the CompactADM unit is inserted, without any software presetting.

Page 350: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

302

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

16.2 OH Connection overview

Here are described the possible OH connections

For OH Phone Parameters directly refer to the para 16.7 on page 311.

– OH Cross–connection

The operator has to be able to cross–connect 2 or more OH bytes on 2 different boards.

The possible cross–connection types are:• unprotected bidirectional point to point

The steps an operator has to do in order to perform the cross–connection are the following:

• create the OH TPs involved in the operation• create the OH cross–connection:

– select type of cross–connection– select the input OH TP involved in the operation– select the output OH TP involved in the operation

After having deleted an OH cross–connection, the involved TPs have to be deleted.

– OH Termination

The operator has to be able to terminate one OH byte onto an auxiliary port or vocal channel.

The steps an operator has to do in order to perform the OH bytes termination are the following:• create the OH TP involved in the operation• create the OH byte termination:

– select the created OH TP– select the auxiliary port/vocal channel TP involved in the operation

After having deleted an OH byte termination, the involved TP have to be deleted.

– Total MSOH Pass–through

For STM ports it make sense to allow the operator to perform a total pass–through of the MSOH bytes.A total msoh pass–through connection (connection between msPassThroughCTP points) is set–up onlyif no single msoh pass–through connection are set and if no single msoh cross–connection are set. If atotal msoh pass–through connection is set, a single msoh pass–through connection or a single msohcross–connection cannot be set.

The steps an operator has to do in order to perform the total MSOH pass–through are the following:• create the msPassThroughCTP points involved in the operation• create the total MSOH pass–through:

– select the input msPassThroughCTP point involved in the operation– select the output msPassThroughCTP point involved in the operation

After having deleted a total MSOH pass–through, the involved msPassThroughCTP points have to bedeleted.

Page 351: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

303

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

16.3 Overhead views

The Overhead Views allows to perform the previously presented operations.

To access select Overhead option from the Configuration pull down menu; the following options arepresented in the cascading menu, as shown in the following figure:

• OH Cross Connection See next para.

• OH Phone Parameters See para.16.7 on page 311.

• OH TP creation See para.16.5 on page 309.

• OH TP deleting See para.16.6 on page 310.

Figure 220. Overhead options

The options are described in next paragraphs.

Page 352: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

304

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

16.4 OH Cross Connection

Select the Configuration pull down menu. Select the Overhead option and then from the cascading menuthe OH Cross Connection option.The Cross-Connection Management for OverHead dialog opens (see Figure 221. on page 304 ) andallows to start the configuration.

Figure 221. Cross Connection Management for OverHead dialog (example)

It is similar to the dialog used for the cross–connection of the TP for paths, then the samedescription and functions are valid.Next configuration steps use the Main Cross-Connection for OverHead (see Figure 222. on page 304)dialog and the TP Search dialog (see Figure 162. on page 218), also in this case already described forpath management.

Figure 222. Main Cross-Connection for OverHead dialog

Page 353: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

305

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

For all details, navigation and sequences on these views refer to chapter 15 on page 253.

There is one big difference between the OH TPs and the other kinds of TPs: the OH TPs have to be:• created ONLY BEFORE a cross–connection/termination operation involving them has been

performed.• deleted AFTER a cross–connection/termination deleting involving them has been confirmed.

The current implementation of the TP Search Dialog (TPSD) works only with created TPs.In the following a description of the main functions and commands is given, also to list the Supported andNot Supported operation.

16.4.1 Cross-Connection Management for OverHead dialog

See Figure 221. on page 304

– Supported operations

• Search cross connections/terminations according to one or more of the following filteringattributes: type, TPs . The operator can set the filtering criteria, can start the search and selectone or more cross connections/terminations among those presented in a read–only list as aresult of the search operation. For each crossconnection/termination matching the filteringcriteria, the following information is shown: direction (bidirectional) and the input, output TPsinvolved;

After choosing one or more cross connections/terminations, this dialog allows to:

• Delete the selected xconnection/termination

Note: this dialog disappears only when the user explicitly clicks on the close button.

Delete operations can be performed on several cross connections/termination at the same time.Modify operations can be performed only on single cross connections/terminations.The OH xconnections are automatically active at the moment of their creation.

The operation buttons availability follows some rules:

• The Delete and Print buttons are enabled only if at least one item is selected from the list.A special dialog will ask the user for a confirmation.

• the create button is always enabled. It brings up the Main crossconnection Dialog.

When some operation may affect the existing traffic, the operator is warned about that, and a confirmationdialog must be answered to carry on/cancel the operation. The choices for this dialog are: yes/no forsingle items, yes to all/cancel for multiple items

– Not Supported operation

When used for OH purposes, the Cross-Connection Management dialog doesn’t support the followingfunctionalities:

• Protect cross connections/terminations: all the OH cross connections/terminations areunprotected

• Activate/Deactivate cross connections/terminations: all the OH crossconnections/terminations are automatically active since their creation

• Split cross connection/termination

• Modify Cross Connection Termination

Page 354: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

306

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

16.4.1.1 Main Cross-Connection for OverHead dialog

See Figure 222. on page 304.

According to the philosophy of offering only meaningful operations to the user, and being the OHcrossconnection operations a subset of those applying to the general cross connections (e.g:protectionsare not allowed), some fields of this dialog are disabled.

By clicking on the proper portions of the dialog and on the proper buttons, the operator can perform theoperations hereafter listed:

• selection of the cross–connection type

• selection of the input TP involved in the cross–connection

• selection of the output TP involved in the cross–connection

In order to do that the operator can either type in the involved TPs ID or use the TP Search dialog.

– Supported operations

• When creating a new cross connection, some or all of the following operations are available,depending on the NE type characteristics:

– Choose one input TP

– Choose one output TP

It is possible to directly type in the TP name or to click on the Choose button to select aTP from the TP Search dialog box

16.4.1.2 TP Search dialog

The TP Search dialog (see Figure 162. on page 218) currently offers:

• navigation rack/subrack/board/port

• a list of TPs to choose from

When used in the OH domain, this dialog is a subcase of the most generic TP Search.

The operator can choose among a list of:

• all the possible OH TPs belonging to a specified class: no board selected and MS, RS or VCclass selected

• all the possible OH TPs belonging to a specified board/port: board/port selected and no TPclass selected

• all the possible OH TPs belonging to a specified board/port and class: board/port selected andMS, RS or VC class selected

• all the OH TPs already connected (also accordingly to the connection type)

• all the OH TPs not yet connected

• a combination of the above options

Page 355: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

307

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

In 1660SM and 1650SMC to connect the auxiliary / vocal channels and the Overhead bytes the followingoperative indication must be observed:

1660SM:

– the auxiliary and vocal channels TPs are in the SERVICE board of slot 11

The auxiliary channels are:

• 2 x G.703 2 Mbit/s; in the screen are indicated as:

– r01sr1sl11/port#05–PExpanding this TP, 31 referred TPs are presented

– r01sr1sl11/port#06–PExpanding this TP, 31 referred TPs are presented

• 4 x G.703 64Kbit/s; in the screen are indicated as:

– r01sr1sl11/port#07–P– r01sr1sl11/port#08–P– r01sr1sl11/port#09–P– r01sr1sl11/port#10–P

• 4 x V11; in the screen are indicated as:

– r01sr1sl11/port#01–#01–v11TTP– r01sr1sl11/port#02–#01–v11TTP– r01sr1sl11/port#03–#01–v11TTP– r01sr1sl11/port#04–#01–v11TTP

• 4 x V24; in the screen are indicated as:

– r01sr1sl11/port#01–#01–v24TTP– r01sr1sl11/port#02–#01–v24TTP– r01sr1sl11/port#03–#01–v24TTP– r01sr1sl11/port#04–#01–v24TTP

• 1 x phonic interface (voice channel); in the screen are indicated as:

– r01sr1sl11/port#01–#01–q23TTPExpanding this TP, four referred TPs are presented:• r01sr1sl11/port#01–#001–q23TTP• r01sr1sl11/port#01–#002–q23TTP• r01sr1sl11/port#01–#003–q23TTP• r01sr1sl11/port#01–#004–q23TTP

These TPs permit to connect the voice channel toward four directions.

Page 356: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

308

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

1650SMC:

– the auxiliary and vocal channels TPs are in the SERGI board of slot 05

The auxiliary channels are:

• 1 x G.703 2 Mbit/s (not operative in current release); in the screen is indicated as:

– r01sr1sl05/port#03–PExpanding this TP, 31 referred TP are presented from

• 2 x G.703 64Kbit/s; in the screen are indicated as:

– r01sr1sl05/port#04–P – r01sr1sl05/port#05–P

• 2 x V11; in the screen are indicated as:

– r01sr1sl05/port#01–#01–v11TTP– r01sr1sl05/port#02–#01–v11TTP

• 2 x V24; in the screen are indicated as:

– r01sr1sl05/port#01–#01–v24TTP– r01sr1sl05/port#02–#01–v24TTP

• 1 x phonic interface (voice channel): in the screen are indicated as:

– r01sr1sl05/port#01–#01–q23TTPExpanding this TP two referred TP are presented:• r01sr1sl05/port#01–#001–q23TTP• r01sr1sl05/port#01–#002–q23TTP

These TPs permit to connect the voice channel toward two directions.

1650SMC and 1660SM:

– The other boards used to terminate or cross–connect the OH bytes are the STM–n boards.The OH TP are present in MS, RS and VC4 TP Class.In these TPs the indication “......#0011 to 0099 (MS or RS) are referred to the coordinates of theSection OverHead bytes on the SDH frame (1,1 to 9,9).The voice channel are identified by the “ow” indication, the “FU” is for Future Use, the “NU” is forNational Use, “UC” is for User Channel and “Pass” is for Passthrough channel.

The examples of the figure in this OH connection chapter can be helpful to the operator.

Page 357: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

309

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

16.5 OH TP creation

Select the Configuration pull down menu. Select the Overhead option and then from the cascading menuthe OH TP creation option.The OH TP creation dialog opens (see Figure 223. ) and allows to create the OH TP to cross connect.

In detail, the dialog–box contains the following graphical object:

– a Choose button is used to display a list of OH Tps to be created. The Choose button startsthe TP Search (see Figure 224. ) with predefined filtering; the TP Search dialog allows theoperator to visualize only not created OH Tps.To visualize the OH TP in the TP Search view double click on the MS, RS or VC4 Tp.

– OH Tp field displays the label of the selected OH Tp to be created.

Apply button is used to perform a create request of the tp displayed in the OH Tp field. After havingperformed the create request, the OH Tp field is set to empty.Close button close the dialog without changes of the data.Help button provides some useful information about the dialog.

Figure 223. OH TP creation

Figure 224. OH Search TP for creation (example)

Page 358: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

310

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

16.6 OH TP deleting

Select the Configuration pull down menu. Select the Overhead option and then from the cascading menuthe OH TP deleting option.The OH TP deleting dialog opens (see Figure 225. ) and allows to delete the OH TP no more involvedin an OH cross–connection.

In detail, the dialog–box contains the following graphical object:

– a Choose button is used to display a list of OH Tps to be deleted. The Choose button startsthe TP Search with predefined filtering; the TP Search dialog allows the operator to visualizeonly created and not cross–connected OH Tps.

– OH Tp field displays the label of the selected OH Tp to be deleted.

Apply button is used to perform a delete request of the tp displayed in the OH Tp field. After havingperformed the delete request, the OH Tp field is set to empty.

Close button close the dialog without changes of the data.

Help button provides some useful information about the dialog.

Figure 225. OH TP deleting

Page 359: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

311

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

16.7 OH Phone Parameters

The OH phone parameters option permits to configure the telephone number and to manage theparameter “phonic extension”.

Select the Configuration pull down menu. Select the Overhead option and then from the cascading menuthe OH Phone Parameters option. Figure 226. opens.

r01sr1sl11/port#01–#01–q23TTP

Figure 226. Phone Parameters dialog window (example)

In the window are presented:

– the interface field (at the top) where can be selected the phonic interfaces to be configured.It identifies a TP indicated as “q23TTP”, referred to the physical voice connection on the SERVICEunit in slot11.

– the phone number field, to set the telephone number for operator call on the phonic interface.

– The phonic extension field, where enable or disable the extension of the selected phonic interface.If enabled the phonic signal is extended towards the external on the access panel of the NE.

Apply button performs the configuration change of the modified phone parameters of the selected phonicinterface without close the dialog

Close button close the dialog without changes of the data.

Page 360: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

312

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 361: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

313

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17 PERFORMANCE MONITORING

17.1 Introduction

The Performance Monitoring domain on the NE covers the monitoring of counter values for trailtermination points and connection termination points.

Examples of these counters on the SDH PORT are Errored Seconds (ES) and Severely Errored Seconds(SES).

The Performance Monitoring domain counts these errors during specified granularity periods (15 min,24h) and stores the values in history data logs.

For the purpose of quality supervision, the values of the error counters can be compared to user-definedthreshold levels. If a counter value has crossed a threshold level, a notification (threshold crossing alarm)is issued.

The principle performance management functions are:

– Configuration of the counting interval for each performance measurement point.

– Collection of the performance data.

– Configuration of the quality thresholds that generate alarms and log records when predefined valuesare exceeded.

On the ETHERNET PORT a set of performance counters are foreseen, for QoS and maintenancepurpose. By selecting the GMAU TP and subsequently the Transmission–>Performance menu, thefollowing options are available:

– Configure Performance Monitoring.

– Display Current Data.

– Display History Data.

Page 362: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

314

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.2 Performance Monitoring on SDH port

17.2.1 Overview

Performance Monitoring functionalities, are described in the following paragraph in addition to generalinformation concerning performance monitoring on the NE.

– Paragraph 17.4 on page 325 Configuration ( SDH port) deals with the configuration of performancemonitoring

– Paragraph 17.5 on page 330 Display Current Data ( SDH port) deals with displaying currentperformance data

– Paragraph 17.6 on page 333 Display History Data ( SDH port) deals with displaying historyperformance data

– Paragraph 17.7 on page 335 PM Threshold Table Selection ( SDH port) deals with the selectionof threshold tables

– Paragraph 17.8 on page 339 PM Threshold Table Modification/Display ( SDH port) deals withthe modification of threshold tables and permits to display the same

17.2.2 Supported Performance Counters

The NE uses performance counters to count transmission errors.

A set of performance counters is provided according to the Termination Point (TP), where performancemeasurement occurs.

The user can start performance monitoring on one or more subsets of counters for each TP; it is notpossible to start individual performance counters.

Near end performance monitoring events are:

– Background Block Error (BBE): A BBE counter measures the number of errored blocks which donot occur as part of an SES.

– Errored Second (ES): A one second period with one or more errored blocks or with a defect.

– Severely Errored Second (SES): A one second period which contains > 30% of errored blocks, orat least one Severely Disturbed Period (SDP). An SES is also counted as an ES.

– Near End Unavailable Second (NEUAS): An Unavailable Second is a second which is part of theUnavailable Time.

The corresponding Far End (FE) performance monitoring events are:

– Far End Background Block Error (FEBBE): A far end errored block which does not occur as partof an FESES.

– Far End Errored Second (FEES): Identifies, at a terminal, a one second period with one or moreerrored blocks or with a defect which were received by the Far End Terminal.

– Far End Severely Errored Second (FESES): Identifies, at a terminal, a one second period whichcontains > 30% of errored blocks, or at least one Severely Disturbed Period (SDP) which wasreceived/detected by the Far End Terminal. An FESES is counted as an FEES.

Page 363: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

315

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Far End Unavailable Second (FEUAS): An Unavailable Second is a second which is part of theUnavailable Time at the far end.

The Termination Point (TP) type determines which performance monitoring events can be counted:

– SDH TPs

Both near end and far end counters are supported in receive direction of the signal for all SDH pathlayers and for the multiplex section layer. For the regenerator section, no far end information istransmitted and, therefore, only near end counting is supported.

– PDH TPs

Only near end counters are supported in receive direction for all PDH path layers.

Further definitions:

– Errored Block (EB): A block in which one or more bits associated with the block are erroneous.

– Remote Error Indicator (REI) [formerly Far End Block Error (FEBE)] : Identifies, at a terminal,the count of errored blocks that were received by the far end terminal.

– Remote Defect Indicator (RDI) [formerly Far End Receive Failure (FERF)]: indicates to a terminalthat the far end terminal has detected an incoming failure.

– Unavailable Time (UAT): A period of unavailable time begins at the onset of 10 consecutive SESevents. These 10 seconds are considered to be part of unavailable time. A new period of availabletime begins at the onset of 10 consecutive non-SES events.

– Pointer Justification Event (PJE): A PJE is an inversion of I– or D– bits of the pointer , togetherwith an increment or decrement of the pointer value to signify a frequency justification.

– Out of Frame Second (OFS) ): An OFS is defined as a second in which one or more out of frameevents have occurred. This event is identified by the A1/A2 byte of the SDH Frame.

The counting of OFS is only supported for the regenerator section termination. Please note that thiscounter is deprecated by ETSI and will be removed from international standards.

Page 364: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

316

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.2.3 Far End (FE) and Near End (NE) Performance Counting

Far end performance monitoring parameters are derived from Remote Defect Indicators (RDI) andRemote Error Indicators (REI) (refer to Figure 227. ).

far endcounter

far endcounter

near endcounter

RDI insertion

signifi-cant bits

signifi-cant bits

near enddefect

far enddefect

signifi-cant bits

signifi-cant bits

far enddefect

Source

Sink

Sink

Source

Node A Node B

near enddefect

RDI inser-tion

trans-missionsignal

trans-missionsignal

near endcounter

Figure 227. Far End Performance Monitoring Principles

– At Node A, the near end information represents the performance of the unidirectional section/pathfrom B to A, while the far end information represents the performance of the unidirectionalsection/path from A to B.

– At Node B, the near end information represents the performance of the unidirectional section/pathfrom A to B, while the far end information represents the performance of the unidirectionalsection/path from B to A.

Near end performance data at Node A and far end performance data at Node B correspond as long asneither direction is disturbed, and vice versa.

In compliance with ETSI and ITU-T standards, far end errors cannot be counted in the case of near endfailures.

17.2.4 Bidirectional counting (24 h Bi) for QoS

As specified in G.826, G.784 and ETSI 300417, the bidirectional PM collection for Quality of Service hasbeen supported by combining the information on each direction of transport to assess a singleunavailability state: the bidirectional path is in the unavailable state if either one or both directions are inthe unavailable state.PM data are collected by a single UAS plus two sets of three event counters (BBE,ES,SES) for NE–PMand FE–PM respectively. When the path transports unidirectional payload just the four counters for theNE–PM are activated (BBE, ES, SES and UAS).Data collection is performed only on 24 hours registers and the NE maintains a buffer of two registers: the24hours current registers and the historical one.

Page 365: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

317

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.2.5 End to End (e–e 24h) Performance Counting

VCn trails can be monitored in intermediate node through the activation of performance monitoringprocess on Monitoring function.

As the trails are often responsible of the end–to–end customer service, the end to–end monitoring can berequested to provide monitoring for Quality of Service purposes and , in addition, for network Maintenanceapplications.

If SNCP is configured the Quality of Service collection have to be enable in the monitoring functions afterthe matrix .

End to end monitoring is achieved by activation of Performance monitoring on the two direction of pathand using far–end primitives. This process can be unidirectional (for Monitoring) or bidirectional process(for QoS).

In case of unidirectional process one direction can be monitored end to end and both 15minute and 24h collection can be activated 15min./ 24H FE_BBE, FE–ES, FE–SES, FE–UAS on incoming or egresssignal depending of the POM is enable. The TCA are also evaluated in both 15 minute and 24 H counters.

The bidirectional process needs the presence on the two Monitoring functions in the two directions in oneNE and among the two monitoring function a 24 hour collection can be activated with the collection ofincFE_BBE, incFE–ES, IncFE–SES, UAS, eFE–BBE, eFE–es, eFE–SES.

17.2.6 Performance Monitoring on AU–PJE

AU PJE (Administrative unit point justification event) is an optional parameters request in G.784.

For AU PJE counters , the positive and negative PJE shall be counted separately on one selectable AUwithin an STM–N signal, after the AU has been resynchronized to the local clock. Refer to G.783.

The number of positive and negative outgoing PJE per second are collected in 15 minutes and 24 Hcounters. A history of 16 x 15minutes counters and 2x 24H are stored in the NE for each AU selected.

No Threshold crossing mechanism is supported on AU–PJE counters.

Page 366: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

318

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.2.7 Tandem Connection Termination (TCT) and Monitoring (TCM)

TCM allows monitoring within the operator domain. The quality within the operator’s own domain can beproven regardless of the received quality of the signal at the entry point of the network. At the input pointthe reference value is set to zero by using the TCM feature.

Tandem Connection Monitoring is applicable to VC–4–nc (n=1, 4, 16, ...), VC–4, VC–3 and VC–12 layers.

TCM provides:

– Incoming error count (IEC);– TC_REI to indicate errored blocks within the TC to the far end;– OEI to indicate errored blocks of the egressing VC–n;– TC_API as access point identifier complying with generic 16–byte string format;– TC_RDI indicating to the far end that defects have been detected within the TC at the near end TC

sink;

17.2.8 Performance Monitoring on 2 Mbit/s ISDN–PRA

The feature provides PM data collection at the 2 Mbit/s ISDN–PRA terminations.The performance monitoring capabilities (applied on p12Mon TP) support both the standard datacollection modes:

– G. 826 bidirectional for QoS

– M2120 unidirectional near–end / far–end for maintenance

17.2.9 Performance Data Collection

Near end and far end performance monitoring events are counted over fixed monitoring periods of 15minutes and 24 hours.

The 24-hour monitoring periods start at 00 : 00 (UTC) and the 15-minute monitoring periods start atxx : 00, xx : 15, xx : 30 and xx : 45.

Performance monitoring can be enabled and disabled at any time during a monitoring period. An entityof all near end or far end performance monitoring events is always counted, it is not possible to startindividual performance counters (e.g. SES only). BBE, ES and SES counting is stopped duringUnavailable Time.

Event Counting

The performance events (e.g. SES) are counted in a counter per event. These counters are called thecurrent registers. At the end of the monitoring period, the contents of the current registers are transferredto the first of the recent registers, together with a time stamp to identify the period (including the day). Timestamping is performed using UTC (as for all alarms). After that, the current register is reset. It is alsopossible to reset an individual current register manually.

Suspect Flag

A suspect interval flag is set as an indication that the data of the corresponding register may be eitherincomplete or invalid.

Page 367: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

319

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Zero Suppression

Zero suppression is a basic mechanism to remove irrelevant PM information and to reduce the amountof PM reports in the system. A PM report is suppressed and hence no history record is created by the entitywhich is responsible for PM reporting when all of the following conditions are true for the monitoring period:

– an interval is error-free (all PM counter values are zero)– PM was enabled during the entire monitoring interval (the elapsed time equals its nominal value, i.e.

900 for 15 min. and 86400 for 24 h)– PM was running properly (the suspect interval flag is not set)

By default, zero suppression is active for all PM enabled TPs. The number of suppressed intervals isindicated.

17.2.10 Data Collection

N.B. PM data is not counted on boards that were plugged out at the moment of enabling datacollection (see PM Configuration dialog). Nevertheless, PM data is counted on boards thatwere plugged in at the moment of enabling data collection, but were plugged out and back insome time during data collection.

Performance Monitoring can be started at any time.

As soon as Performance Monitoring is started on the Craft Terminal, current PM data is collected on theI/O boards, incrementing the performance counters each time an error is detected.The performance data counted is evaluated every quarter of an hour or every 24 hours and stored therein a history record.

When the user disables the monitoring of a TP within the first 10 minutes of a 15-minute period, it ispossible that have still not been received the PM data of the previous monitoring interval.Since PM data is not stored after monitoring is disabled, the PM data of the previous interval is lost in thiscase.

If equipment or line protection switching occurs during a counting interval, the NE does not providecomplete performance measurement for the protected TPs.Only the period between the last switch and the end of the counting window is counted.The interval is marked for suspect data and the elapsed time indicates the length of the measured period.

17.2.11 Performance Monitoring History

Performance Monitoring history data is necessary to assess the recent performance of transmissionsystems. Such information can be used to sectionalize faults and to locate the source of intermittent errors.History data, in the form of performance monitoring event counts, is stored in registers in the NE. All thehistory registers are time stamped.

In compliance with ETSI and ITU-T standards, the history registers operate as follows:

The history data is contained in a stack of registers. There are sixteen 15-minute period registers and one24-hour period registers per monitored event. These registers are called the recent registers. At the endof each monitoring period, the contents of the current registers are moved to the first of the recent registers.When all recent registers are full, the oldest information is discarded.

Page 368: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

320

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.2.12 Thresholds

For quality supervision purposes, the recorded errors through the performance counters can be comparedto threshold levels. If a counter value has crossed a threshold level, a Threshold Crossing Alarm (TCA)is transmitted to the alarm manager.

The threshold values are defined in threshold tables together with a severity and a flag indicating whethercrossing this value should be notified by an alarm and logged or only stored in the current problem list.The user can modify and delete such tables.

Different thresholds can be assigned for near end and far end and for granularity of 15 minutes and 24hours.

The TCA only reports the value of the counter which has crossed the threshold, it does not provide acomplete set of all counters. Therefore, the user has to explicitly retrieve all current performance data afterreceiving the alarm. The user can retrieve this information from the Current Performance ManagementData Dialog.

Two thresholds mechanism are supported:

– For 24–hour (implicit clearance) monitoring periods, one threshold value is defined: if the event countreaches or exceeds the threshold value during the monitoring period, a TCA is generated. To cleara TCA, the alarm must be manually acknowledged by the user.

– For 15–minute (explicit clearance) monitoring periods, two threshold values (set, reset) are defined:a TCA is generated during the monitoring period when the event count reaches or exceeds the setthreshold value the first time. This TCA is automatically cleared by the system at the end of thefollowing monitoring period in which the event count is less than or equal to the reset threshold valueand there was neither an unavailable nor a suspect period during this monitoring period

The following limitations apply for explicit clearance:

– The value of the low threshold is fixed to “0” (only a single threshold is provided by a threshold table).

– An SES threshold crossing is cleared at the end of the interval if no unavailability was detected andSES had not reached the low threshold (low threshold equal to 0).

– Even in case of a suspect interval the TCA is cleared if no unavailability was detected and the lowthreshold had not been reached.

Additionally an explicit clearance of TCAs for all granularity periods is executed if one of the followingevents occurs during the current interval:

– deletion of the current data instance (TP),

– resetting of counters (only for 24 h),

– increased thresholds (higher than current value of counters) (only for 24 h).

Page 369: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

321

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.3 Performance Monitoring on ETHRNET port

Performance Monitoring on Ethernet port, can be applied to ETH–ATX, GETH–AG, ETH–MB, GETH–MBcads and are described in the following paragraphs:

– Paragraph 17.9 on page 343 Configuration (Ethernet port) deals with the configuration ofperformance monitoring

– Paragraph 17.10 on page 344 Display Current Data (Ethernet port) deals with displaying currentperformance data

– Paragraph 17.11 on page 348 Display History Data (Ethernet port) deals with displaying historyperformance data

An Ethernet link can be defined between two 10/100 Ethernet interfaces, or between two Gb Ethernetinterfaces, or also between a Fast Ethernet and a Gb Ethernet interface.

At the terminations of Ethernet link, it s possible to monitor the Ethernet frames and to collect informationabout the Ethernet traffic by means of some counters.

Definitions of incoming and outgoing counter direction

[1] Incoming (network centric view): it refers to the direction starting from Ethernet domain toward SDHdomain (see Figure 228. ). The traffic arrives to the board from an Ethernet link and goes out froman SDH link.

[2] Outgoing (network centric view): it refers to the direction starting from SDH domain toward Ethernetdomain (see Figure 228. ). The traffic arrives to the board from an SDH link and goes out from anEthernet link.

Figure 228. Counter directionality: network centric view

Page 370: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

322

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.3.1 Overview

Ethernet counters can be distinguished from different points of view as depicted in Figure 229.

They are:

– Physical interface counters

– Aggregate counters

– Flow counters

Besides this classification, some counters can be of Quality of Service, others only of maintenance.

Symbol ErrorMedia Available ExitsJabber State False Carrier

TRCOinTRCFinTDFin

TRCOoutTRCFoutTDFout

TTOinTTFin

Port interface#1

TTOoutTTFout

Interface FlowAggregate Counters CountersCounters

TRSEFin

TRSEFout

Eth

ern

et

SD

H

Figure 229. Counter subdivision

17.3.2 Ethernet physical interface counters

Ethernet physical interface counters are used to test Ethernet interface working state.

They are:

– Symbol Error : for an interface operating at 100Mb/s, the number of times there was as invalid datasymbol when a valid carrier was present. For an interface operating in full–duplex mode at 1000 Mb/s,the number of times the receiving media is non–idle carrier event for a period of time equal or greaterthan minFrameSize, and during which there was at least one occurrence of an event that causes thePHY to indicate Data reception error on the GMII. The count represented by an instance of this objectis incremented at most once per carrier event, even if multiple symbol errors occur during the carrierevent. This count does not increment if a collision is present.

– Media Available Exits : number of times that ifMauMediaAvailable for this MAU instance leavesthe state available. Discontinuities in the value of this counter can occur at re–initialization of themanagement system, and at other times as indicated by the value of ifCounterDiscontinuityTime

Page 371: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

323

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Jabber State : number of times that mauJabberState for this MAU instance enters the statejabbering. This counter will always indicate zero for MAUs of type dot1MauTypeAUI and those ofspeeds above 10Mbps. Discontinuities in the value of this counter can occur at re–initialization of themanagement system, and at other times as indicated by the value ifCounterDiscontinuityTime.

– False Carrier: number of false carrier events during IDLE in 100BASE–X and 1000BASE–X links.For all other MAU types, this counter will always indicate zero. This counter does not increment atthe symbol rate. It can increment after a valid carrier completion at a maximum rate of once per 100ms for 100BASE–X and once per 10µs for 1000BASE–X until the next CarrierEvent. Discontinuitiesin the value of this counter can occur at re–initialization of the management system, and at other timesas indicated by the value of ifCounterDiscontinuityTime.

They are only maintenance counters.

17.3.3 Aggregate counter

Aggregate counters count frames that pass through the same port.

Aggregate counters are:

– TRSEF (Total Received Service Errored frames): it is the sum of three contributions.

• Alignment Errors:A count of frames received on a particular interface that are not an integral number of octetsin length and do not pass the FCS check.The count represented by an instance of this object is incremented when the alignment Errorstatus is returned by the MAC service to the LLC (or other MAC user).Received frames for which multiple error conditions obtain are, according to the conventionsof IEEE 802.3 Layer Management, counted exclusively according to the error status presentedto the LLC.

• FCSErrors :A count of frames received on a particular interface that are an integral number of octets inlength but do not pass the FCS check. This count does not include frames received withframe–too–long or frame–too–short error.The count represented by an instance of this object is incremented when the frameCheckErrorstatus is returned by the MAC service to the LLC (or other MAC user).Received frames for which multiple error conditions obtain are, according to the conventionsof IEEE 802.3 Layer Management, counted exclusively according to the error status presentedto the LLC.Note: Coding errors detected by the physical layer for speeds above 10 Mb/s will cause theframe to fail the FCS check.

• Frame Too Longs :Number of received Ethernet frames that exceed the MTU.The count represented by an instance of this object is incremented when the frameTooLongstatus is returned by the MAC service to the LLC (or other MAC user).Received frames for which multiple error conditions obtain are, according to the conventionsof IEEE 802.3 Layer Management, counted exclusively according to the error status presentedto the LLC.

They are Quality of Service counters.

Page 372: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

324

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

SDH VC–npipe

Node A Node B

Transmittedframes

Receivedframes

OMSN OMSN

TRSEF incomingTRSEF outgoing

ISA Eth/GbE port ISA Eth/GbE port

Incoming direction Outgoing direction

Eth –> SDH SDH –>Eth

Figure 230. Ethernet Aggregate counter

17.3.4 Flow counter

Counters definitions are: .

– TRCO (Total Received Correct Octets): total number of octets of Ethernet frames received correctly,including Ethernet header characters.

– TRCF (Total Received Correct Frames): total number of Ethernet frames received correctly

– TDF (Total Discarded Frames): total number of Ethernet frames which were chosen to be discardeddue to buffer congestion.

– TTO (Total Transmitted Octets): total number of octets of Ethernet frames transmitted out, includingEthernet header characters.

– TTF (Total Transmitted Frames): total number of Ethernet frames transmitted out.

SDH VC–npipe

Node A Node B

Transmittedframes

Receivedframes

OMSN OMSN

TRCO incomingTRCF incoming

TDF incoming

TTO incomingTTF incoming

TRCO outgoingTRCF outgoing

TTO outgoingTTF outgoing

ISA Eth/GbE port ISA Eth/GbE port

TDF outgoing

Incoming direction Outgoing direction

Eth –> SDH SDH –>Eth

Figure 231. Ethernet Flow counter

Page 373: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

325

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.4 Configuration (SDH port)

Use menu item Add TP to display a special TP in the Transmission menu (see para.14.5 on page 217).

Select the TP and open the PM Configuration dialog (see Figure 232. ) by clicking on the menu itemTransmission –>Performance –>Configure Performance Monitoring.

This “PM Configuration” dialog serves as the main interface to all PM services. Everyconfiguration of all monitoring intervals is defined using this dialog.

It is possible to access the same “PM Configuration” dialog selecting a TP in the “Port view” and openingthe same Performance > Configure Performance Monitoring option in the Port pull down menu (seepara.11 on page 139).

N.B. To configure PM for au4CTPs and tuxCTPs, Path Overhead Monitoring (POM) ,SupervisedUnequipped Termination (SUT, not supported) or Tandem Connection (TCT, TCM) must becreated first (see description in para. 14.9 on page 236 ).

The PM Configuration dialog is designed as a notebook consisting of a text field, to identify the selectedTP, and page labels.

The selected TP is indicated in the first box at the top of the screen: TP Identifier.

Page 374: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

326

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

In case of au4CTP tuxCTPs and VcxCTP, the PM Configuration dialog also contains a cascading menuthat allows to configured the POM/SUT/TC options as follow:

– PathOverhMon After Matrix

– PathOverhMon Before Matrix

– TP (Performance is made on AU–PJE )

– TCM After Matrix

– TCM Before Matrix

– TCT Bidirectional After Matrix

– TCT Bidirectional Before Matrix

When more than one of the above options is chosen, a Question dialog box is displayed (see Figure 233. );click on Cancel to continue or OK to interrupt any action.

N.B. As long as the PM Configuration dialog is open, a modified POM/SUT/TC configuration is notautomatically recognized and displayed. This may lead to rejections or confirmations offorbidden PM configuration. Therefore make sure to reopen the PM Configuration dialog eachtime the POM/SUT/TC configuration is changed.

Each page label presents a range of parameters for one near end or far end granularity period (15 min.or 24 h) which together form a dataset. To select a special page label, click on the top part of the label:

• NE15, near end 15 minutes page

• NE24, near end 24 hours page

• FE15, far end 15 minutes page

• FE24, far end 24 hours page

• 24hBi , near and far end 24 hours page bidirectional (UAS is the sum of far end and near end)

• e–e 24h , end to end 24 hours page (enable only on HPOM)

Each dataset has to be configured independently. For AU–4 CTP and TU–x CTP the highest criteria isPOM and SUT. I.e. select the POM or SUT option first and then configure the different associated datasets.Confirm the configuration with Apply before you continue with a different POM or SUT option.

Page 375: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

327

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 232. PM Configuration Dialog (example)

Figure 233. PM question dialog box (example)

Page 376: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

328

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Activate any item within the page label by selecting the respective radio button.

– Mode

• Data Collection

Select this button to activate performance monitoring. Disabling Data Collection leads toclearance of the current and all history data of this entity.

• Create History Data

If this item is selected, history data collection is performed in the selected entity for thecorresponding TP.

Note that on disabling this mode item, no history data is available. Nevertheless, datasetscollected prior to deactivation are not cleared and are displayed after re-enabling the item, aslong as the number of displayed datasets does not exceed 16 for 15 min. granularity and onefor 24 hours granularity.

• Lock Data Collection. Not supported

If Lock is selected, PM remains enabled but data collection is stopped. All history performancedata remain available. All current values are set to zero.

– EML OS Monitoring (only accessible from SH)

Not available for Craft Terminal.

– Notifications

• UAT (only available for 24 h granularity)

For 24 h granularity, UAT (UnAvailable Time) notifications are created if enabled. Thisnotification results in an UAT alarm in the Alarm Surveillance.

N.B. This parameter can only be selected during creation and cannot be subsequentlymodified.

• Suppress Additional Threshold

Disabled: the alarm is generated every time the value exceed the upper threshold (value up).

Enabled: after a first alarm generation, the alarm is generated again when the value exceed theupper threshold (value up) after the lower threshold (value down) has been exceeded.

– Threshold Table

Attach a threshold table to the selected TP. Only assign threshold tables that match the granularityperiod of the datasets (i.e. a 15 min. threshold table must not be assigned to a 24 h dataset).Otherwise the Transmission view is blocked and only released by closing and reopening the PMConfiguration window and the Transmission view.Click on button Attach... to open the PM Threshold Table Select dialog (see Figure 236. ) andconfigure the threshold table (see Chapter 17.7 on page 335).Select button Remove to disassociate the threshold table from the entity.

N.B. A threshold table can only be attached if Data Collection is enabled.

Page 377: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

329

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

– Set Alarm Severity UAT

• ASAP Id

This field shows the label of the ASAP pointer assigned to the UAT alarm

• Set ASAP

Allows to set a new ASAP pointer for the UAT alarm. The Set ASAP button opens the windowdisplayed in Figure 20. on page 57.

The Tp List... button opens the Clipboard windows; for details refer to paragraph 4.3.2.3 on page 59.

Confirm the configuration with the button Apply before closing the dialog. Otherwise the configuration islost.

Page 378: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

330

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.5 Display Current Data (SDH port)

Use menu item Add TP to display a special TP in the Transmission view (see para.14.5 on page 217).

Select the TP and open the Current PM Data dialog (see Figure 234. ) by clicking on the menu itemDisplay Current Data.

This “Current PM Data” dialog serves to show the results and status of the PerformanceMonitoring counters.It is possible to access the same “Current PM Data” dialog selecting a TP in the “Port view” and openingthe same Performance > Display Current Data option in the Port pull down menu (see para.11 on page139).The Current PM Data dialog is designed as a notebook consisting of a text field, to identify the selectedTP, and page labels.The selected TP is indicated in the first box at the top of the screen: TP Identifier.

In case of au4CTP tuxCTPs, VCxCTP the Current PM Data dialog also contains a cascading menu thatallows to choose the POM/SUT/TC options to display as follow:

– PathOverhMon After Matrix

– PathOverhMon Before Matrix

– TP (Performance is made on AU–PJE )

– TCM After Matrix

– TCM Before Matrix

– TCT Bidirectional After Matrix

– TCT Bidirectional Before Matrix

Page 379: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

331

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Each page label presents a range of parameters for one “near end and far end” granularity period (15min.or 24h) which together form a dataset. To select a special page label, click on the top part of the label:

• 15 min, near end and far end 15 minutes page• 24 h, near end and far end 24 hours page• 24hBi, far end 24 hours page bidirectional (UAS is the sum of far end and near end)• e–e 24h, end to end 24 hours page (enable only on HPOM)

All datasets available which are related to the selected TP and recorded in the current monitoring intervalare displayed in this dialog.

The following items are indicated for each entity:– Administrative State

Indicates whether the PM collection is locked for the local user or not.– Operational State

Indicates whether PM is enabled or disabled.– Suspect Data

Indicates if collection errors occurred during the collection period.– Threshold Table– Indicates which threshold table is assigned to the entity.– Current Problem List

Indicates current UAT (“Unavailable”) and TCA (“ThresholdCrossed”) alarms.

N.B. The entry “Unavailable ThresholdCrossed” indicates, that both alarms are active. Sincethe text field is too small to display the full text at a time, use the cursor to scroll the textfield in this case.

– Elapsed TimeIndicates the time which has elapsed since the monitoring interval was started. This information tellsthe user whether the data collection covers the whole period.

At the bottom the PM results are listed.

Reset button is used to restart the counting period. Two buttons are present for near–end and far–endperiods.Press the Refresh button to update the window contents and display the latest data.Using the Print button, PM data can be saved to a file or printed on paper.

N.B. If no printer is installed, there is no error message displayed to indicate this.

Page 380: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

332

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 234. Current PM Data Dialog (example)

Page 381: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

333

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.6 Display History Data (SDH port)

Use menu item Add TP to display a special TP in the Transmission view (see para.14.5 on page 217).

Select the TP and open the PM History Data dialog (see Figure 235. ) by clicking on the menu itemDisplay History Data.

This “PM History Data” dialog serves to show stored Performance Monitoring counting.It is possible to access the same “PM History Data” dialog selecting a TP in the “Port view” and openingthe same Performance > Display History Data option in the Port pull down menu (see para.11 on page139).

The PM History Data dialog is designed as a notebook consisting of a text field, to identify the selectedTP, and page labels.

The selected TP is indicated in the first box at the top of the screen: TP Identifier.

In case of au4CTP , tuxCTPs VCxCTPs, the PM History Data dialog also contains a cascading menu thatallows to choose the POM/SUT/TC options to display as follow:

– PathOverhMon After Matrix

– PathOverhMon Before Matrix

– TP (Performance is made on AU–PJE )

– TCM After Matrix

– TCM Before Matrix

– TCT Bidirectional After Matrix

– TCT Bidirectional Before Matrix

Each page label presents a range of parameters for one “near end and far end” granularity period. To selecta special page label, click on the top part of the label.

Page 382: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

334

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

All available datasets (entities), which are related to the selected TP, are displayed in the table:

• 15 min, near end and far end 15 minutes page• 24 h, near end and far end 24 hours page• 24hBi, far end 24 hours page bidirectional (UAS is the sum of far end and near end)• e–e 24h, end to end 24 hours page (enable only on HPOM)

The PM data is displayed containing information concerning:

– Interval End Timein the format dd.mm.yyyy hh:mm:ss.

– The number of recorded events concerning an entity is divided into near end and far end data

– Elapsed Timeindicating whether the data collection was complete (see para. 17.2.10 on page 319)

– suspindicating suspect data where collection errors occurred during the collection period.

In case of 15 min. entities, a maximum of 16 datasets can be displayed simultaneously for each counter,the 24h entities display a maximum of one dataset. These figures cannot be changed by the user.

If the limit of 16 datasets for 15 min. granularity and one datasets for 24 h granularity is reached, the oldestset in the list is cleared when the next data set arrives.

Using the Print button, PM data can be saved to a file or printed on paper.

N.B. If no printer is installed, there is no error message displayed to indicate this.

Monitor

Figure 235. PM History Data Dialog (example)

Page 383: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

335

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.7 PM THRESHOLD TABLE SELECTION (SDH port)

The PM Threshold Table Select dialog (see Figure 236. ) pops up if the Attach button is clicked in thePM Configuration dialog (see Figure 232. ).

In addition, this dialog can be accessed using the Configuration menu:

N.B. Do not open several dialogs at the same time using both possibilities. Since those dialogs arenot synchronized, they could display different contents.

The dialog presents a list of existing threshold tables.

The tables are individually indicated with a number.

Each table is dedicated to a specific entities, as reported in Table 10. Each table can be modified accordingthe operator selections.

The filtering criteria are not operative.

The user can perform the following actions:

– Create / Modify / Display a threshold table.

– Delete an existing threshold table

Mark the table in the list and click on the Delete button.

Note that a threshold table cannot be deleted if it is attached to a PM entity. An error message informsthe user of this situation.

– Attach the selected threshold table to a TP entity. It is only available entering from the PMConfiguration dialog (see Figure 232. )

The user has to close the dialog explicitly by clicking on the button Close.

Page 384: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

336

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

1660SM example 1640FOX and 1650SMC

Figure 236. PM Threshold Table Select

Page 385: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

337

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Table 10. 1660SM Threshold table entities association

N layer TP’s ASSOCIATED granularity

1 STM16 RS 15 minutes

2 STM16 RS 24 hours

3 STM4 RS 15 minutes

4 STM4 RS 24 hours

5 STM1 RS 15 minutes

6 STM1 RS 24 hours

7 STM16 MS Near End / Far End 15 minutes

8 STM16 MS Near End / Far End 24 minutes

9 STM4 MS Near End / Far End 15 hours

10 STM4 MS Near End / Far End 24 hours

11 STM1 MS Near End / Far End 15 minutes

12 STM1 MS Near End / Far End 24 hours

13 VC4 Path Termination Near End / Far End 15 minutes

14 VC4 Path Termination Near End / Far End 24 hours

15 VC3 Path Termination Near End / Far End 15 minutes

16 VC3 Path Termination Near End / Far End 24 hours

17 VC12 Path Termination Near End / Far End 15 minutes

18 VC12 Path Termination Near End / Far End 24 hours

Table 11. 1640FOX and 1650SMC Threshold table entities association

N layer TP’s ASSOCIATED granularity

1 STM4 RS 15 minutes

2 STM4 RS 24 hours

3 STM1 RS 15 minutes

4 STM1 RS 24 hours

5 STM4 MS NE / FE 15 minutes

6 STM4 MS NE / FE 24 hours

7 STM1 MS NE / FE 15 minutes

8 STM1 MS NE / FE 24 hours

9 VC4 Path Termination NE / FE 15 minutes

10 VC4 Path Termination NE / FE 24 hours

11 VC3 Path Termination NE / FE 15 minutes

12 VC3 Path Termination NE / FE 24 hours

13 VC12 Path Termination NE / FE 15 minutes

14 VC12 Path Termination NE / FE 24 hours

Page 386: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

338

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

After the activation of a PM on a TP, it will be signalled in the Port view and in the Transmission view asfor the following figures:

PORT VIEW

Active PM

TRANSMISSION VIEW

Active PM

Page 387: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

339

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.8 PM Threshold Table Create / Modification / Display (SDH port)

17.8.1 Creation

The PM Threshold Table Create dialog (see Figure 237. on page 340) pops up when the Create buttonis clicked in the PM Threshold Table Selection dialog (see Figure 236. on page 336).

Carry out the following steps to create a threshold table:

1 ) Enter the table name in input field Name.Leaving the input field blank or entering only blanks is not allowed and rejected.

2 ) Select a Granularity of 15 min. or 24 h for the entity.

3 ) Enter the set (Value Up) and the reset (Value Down) threshold values. Note that the reset valueif supported, will be available with 15 min. monitoring periods.Table 12. on page 341 shows the maximum performance monitoring event values.The respective value is automatically reset to the maximum if a larger figure is entered.

4 ) Select the alarm Severity for each PM attribute in case a threshold is crossed.

5 ) Disable Send notification if no notification message should be sent in the case of a crossedthreshold.

6 ) Confirm the entries with Apply to create the threshold table. A number of threshold tables canbe created from the same window.

Explicitly close the window with button Close.

Page 388: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

340

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 237. Create PM Threshold Table

Page 389: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

341

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.8.2 Modification

The PM Threshold Table Modify dialog (see Figure 238. ) pops up if a threshold table is selected in thePM Threshold Table Selection dialog (see Figure 236. ) and the Modify button is clicked.

Carry out the following steps to modify a threshold table:

1 ) Modify the upper threshold value (Value Up) and the lower value (Value down)

Table 12. shows the allowed maximum performance parameter values.

2 ) Modify the alarm Severity for each PM attribute in case a threshold is crossed.

3 ) Disable Send notification if no notification message should be sent in the case of a crossedthreshold.

Note that the Name (really “number”) cannot be changed.

4 ) Confirm the modifications with Apply.

5 ) To modify more than one threshold table, do not close the dialog, but select the next thresholdtable in the PM Threshold Table Selection dialog and press the Modify button(see Figure 236. ).

Explicitly close the dialog with button Close.

17.8.3 Display

The PM Threshold Table Display dialog (similar to Figure 238. ) pops up if a threshold table is selectedin the PM Threshold Table Selection dialog (see Figure 236. ) and the Display button is clicked.

Refer to the previous chapter for a description of the attribute values and types.

Table 12. Maximum Performance Parameter Values

Performance Parameter Max. Value for 15-min.period

Max. Value for 24-h period

BBE, FEBBE on STM-16 34,559,100 3,317,673,600

BBE, FEBBE on STM-4 8,639,100 829,353,600

BBE, FEBBE on STM-1 2,159,100 207,273,600

BBE, FEBBE 539,100 51,753,600

OFS, ES, UAS, FEES, 900 86,400

SES, FESES 810 78,760

PJC high, PJC low 1,800,000 172,800,000

Page 390: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

342

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 238. Modify PM Threshold Table

Page 391: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

343

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.9 Configuration (Ethernet port)

Use menu item Add TP to display a special TP in the Transmission menu (see para.14.5 on page 217).

Select the TP (Gmau) and open the PM Configuration dialog (see Figure 232. ) by clicking on the menuitem Transmission –>Performance –>Configure Performance Monitoring.

The Create Ethernet Counter window is opened (refer to Figure 239. on page 343)

Figure 239. Create Ethernet counter

In that dialog the operator will be allowed to create/delete the currentData by checking/un–checking thecorresponding checkbox for the incoming and outgoing direction.

Page 392: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

344

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.10 Display current Data (Ethernet port)

Use menu item Add TP to display a special TP in the Transmission view (see para.14.5 on page 217).

Select the TP and open the Current PM Data dialog (see from Figure 241. to Figure 242. ) by clickingon the menu item Display Current Data.

Figure 240. Display Current Data

This “Current PM Data” allows the operator to send a request in order to retrieve the maintenancecounters.

The layout of the dialog ”maintenance counters” is depicted in Figure 242.

At startup the dialog displays an empty table; the dialog allows to choose the polling time and how manytimes the action will be done; the default values for those entries are 0 for polling time and 1 for numberof retries, with that default configuration if the the ”Start polling” button allows to perform the configuredrequest.If the number of retries is bigger than 1, several actions are performed on the NE.During the polling interval the label of the button ”Start polling” will be changed to ”Stop polling”, and forevery response arrived a row is added to the table.Every time the operator push the ”Start polling” button new lines will be added to the lines already presentin the table.

The button ”Display Graph.” allow to visualize the counter values in a graphical view but is not operativein current release.

Page 393: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

345

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 241. Display Current Data example (Interface counters)

Page 394: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

346

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 242. Display Current Data example (Flow counters)

Page 395: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

347

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 243. Display Current Data (Aggregate counters)

Page 396: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

348

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.11 Display history Data (Ethernet port)

Use menu item Add TP to display a special TP in the Transmission view (see para.14.5 on page 217).

Select the TP (Gmau) and open the PM History Data dialog (see Figure 235. ) by clicking on the menuitem Display History Data.

The menu item ”Display History Data” will be opened (refer to Figure 244. ):

– In case of one hour history data, the showed values are the hourly historic data collected by NE.If the NE has collected only one history data, the dialog shows directly counter values.If the NE has collected more than one history data, the displayed counter values are calculated asa difference from the older available history data value.The older one will be added in the first line with the label ”– –” and for each cell a tooltip will show thehistory value received.

In the bottom of the dialog, the description of the showed counters value is dispalyed.

The layout of the dialog ”Display History Data” is depicted in Figure 244. ; this dialog shows the numericvalue for each counter calculated as described before.

The button ”Display Graph.” allow to visualize the counter values in a graphical view but is not operativein current release.

Page 397: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

349

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

OUTGOING

INCOMING

Figure 244. Display History Data

Page 398: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

350

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

17.12 PM overview

This menu provide a NE global view for PM and Monitoring operations helps the operator to list theseresources.

Select the PM overview option from the Configuration menu (refer to Figure 245. ); the PM Overviewdialog will be opened (refer to Figure 246. )

Figure 245. PM Overview menu

PM/Monitoring Overview (PMO) dialog is able to show both PM and Monitoring objects.

Page 399: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

351

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 246. PM overview window

Search operation are allowed for PM objects, monitoring object or both. Search operations are dividedin two phases:

[1] the operator chooses a list of interesting TP using TP search; at the end fo this search operation thenoperator moves such a list of TPs into PMO dialog.These TPs define a list of search roots forMonitoring and PM.

[2] the operator configure the filtering criteria in PMO and starts PM/Monitoring search oeprations usingthe Show button in PMO.

Figure 247. represents the interworking between these two dialogs.

The button area contains the following button (refer to Figure 246. ):

[1] ADD TP: it starts the search operations using the TP Search dialog. Only TP references are movedby TP search into PMO dialog. This is a precondition to start PM/Monitoring search operations, usingTP selected by TP search as search roots.

[2] Show: it starts the search for PM/Monitoring objects in the MIB. according to the filtering criteria.

[3] Reset Filter : it reset all filtering settings to default conditions.

Page 400: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

352

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

[4] Preferences : it start the user preferences dialog. It is greyed out in USM not supporting this feature.

[5] Config PM : it starts the dialog for Current Data create/delete.

[6] Config Mon : it starts the dialog for monitoring object create/delete.

[7] Current Data: it starts the dialog for PM counter visualization

[8] History Data: it starts the dialog for PM counter visualization

[9] Print: it starts a request to print the tree content

[10] Delete: it starts a request to remove the selected objects (monitoring and/or).

[11] Delete All: it destroys the TP list and make empty the TreeGadget

[12] Port View: it starts the Port View . PMO dialog is not closed after Port View or Port details dialogopening.

Page 401: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

353

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 247. PM overview–Tp search windows interworking

Page 402: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

354

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 403: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

355

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18 SYNCHRONIZATION MANAGEMENT

18.1 Introduction

All SDH NEs require timing in order to generate the necessary synchronization and frame phase referenceinformation. The timing can be provided by a source external to the NE or an internal timing generator.The derived timing shall be used for all signals and interfaces in the NE that are related to the SDH framestructure.

Follows a brief description of the heart of the NE clock known as the Synchronization Equipment TimingSource (SETS).

It can be divided into 2 parts:

– OSC: the internal oscillator.– SETG: the Synchronization Equipment Timing Generator.

The SETG is responsible for the generation of the external timing source for the Frame structure and theclock, whilst the internal oscillator (OSC) is useful only in the abnormal functioning ”Free–running” modethat will be explained later.The simplified figure that follows represents the internal organization of the SETS.

SelectorA

OSC

SETG

SelectorC

SquelchA

SquelchB

T1T2

T3/T6 (*)Selector

B

S15 Y

T0

T4/T5 (**)

SETS

NOTES:

(*) T3/T6 are not available on 1640FOX(**) T5 is not available on 1640FOX

Figure 248. Internal organization of the SETS.

The internal sources (inputs) are:

– T1: Reference obtained from incoming STM–N signals,– T2: Reference obtained from incoming 2 Mbits signals,– T3/T6: Reference obtained from an external incoming 2.048 MHz (T3) or 2.048 Mbit/s (T6) signal.

T3/T6 reference clocks are not available on 1640FOX

– OSC: the internal oscillator.

The number of timing reference inputs depends on the configuration of the NE.

Page 404: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

356

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The external sources (outputs) are:

– T0: is the reference output signal for the clock and signal frames,– T4: is the 2 MHz reference output for the external equipment synchronization.– T5: is the 2 Mbit/s reference output for the external equipment synchronization.

T5 reference clock is not available on 1640FOX

Other reference points:

– Y: is used for communication of Synchronization Status Message (SSM) between SETS and MSTfunctional blocks.

– S15: is used to provide notifications and loss of incoming timing reference reporting to theSynchronous Equipment Management Function (SEMF).

Selector A provides the capability to select timing reference from available T1 inputs, either automaticallybased on the priority and quality level of the candidate sources (SSM algorithm), or manual as a result ofcommands issued from the managing system.

Selector B is capable of selecting timing reference from T1, T2, or T3/T6 inputs, according to the SSMalgorithm. The capability for manual selection of the timing source is also provided.

Selector C is only operated in manual mode, to switch between SETG output signal (T0) and a T1 timingreference.

The squelch functions A and B mute the relevant timing references in the presence of failure condition,or SSM threshold violation.

The choice of the timing reference is done in two ways:– Automatically:

Following a particular algorithm based on the quality and the priority of the incoming timing signals.The automatic selection is based either on the priority of the incoming timing source (Priorityalgorithm) or on the priority and the quality level of the incoming sources (SSM algorithm).

– Manually:Following an order from the Operator.

N.B. The priority level is determined by the Operator for each candidate timing source. It is staticinformation. On the other hand, the quality of the source is dynamic information, dependantof the quality of the reference clock generating the timing.In an SDH signal frame, the quality of the timing source is located in the Section Overhead.

The SETG has 3 modes of operation:– Locked mode:

The SETG output is fully controlled by the external timing references (T1, T2 and T3/T6).– Hold–Over mode:

The external timing reference is malfunctioning. The SETG during normal functioning storesregularly the value of the external timing reference. In this case the SETG output is controlled by thismemorized value.

– Free running mode:This is not a normal operating mode. The external timing reference and the memorized timingreference are malfunctioning. In this case the SETG output is controlled by the internal clock source.

Page 405: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

357

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2 Synchronization Management

The operations that can be done on the synchronization sources are the following:

– Timing Source Configuration,– Protection Commands,– T0 Configuration,– T4 Configuration,– SSU Configuration,– Transmitted SSM Quality Configuration,– Frame Mode Configuration (see para. 11.8 on page 170)– Remove Timing Reference,– Change T4<–> T5 (not applicable to 1640FOX)– Set T0 Equal T4,– Change 2 MHz –> 2 Mbit (available only if T3 has been configured as timing source) (not applicable

to 1640FOX)– Remove T0 Equal T4,– Show Timing Source.

Before any other operation the synchronization view has to be displayed.

18.2.1 Displaying the Synchronization View

The synchronization view can be normally opened using the menu Views options (see Figure 249. ).

Using menu options, select the Synchronization option from the Views pull down menu as shown in thefollowing figure.

Figure 249. Obtaining the synchronization view.

Selecting this menu option the synchronization representation will be displayed directly into the currentwindow instead of the current view. All the operations that can be done on the synchronization sourcesare performed from this synchronization view.

Page 406: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

358

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.2 Synchronization View

The Synchronization view shows the external timing reference sources and the T0, T4 or T5, generation.The selection is based on the SSM algorithm or on the priority of the incoming timing sources. Activatingthe SSM algorithm implies that the selection of the source is before done on the quality criteria and thenon the priority criteria for sources at the same quality level.

After selecting the Synchronization option from the Views menu the Synchronization View is visualizedin Figure 250.

Figure 250. Synchronization View Example

Page 407: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

359

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Synchronization View Description

The synchronization view provides two list of allowable timing references:

• one for T0 timing output; T0 list is always present;• one for T4 or T5 timing output; the presence of the T4/T5 list is configurable using resource files.

T0 list contains :

– a timing reference associated to the Internal Oscillator timing source; it is always presentand it cannot be removed or redefined.

– 6 max timing reference for candidate inputs belonging to the allowable timing referenceT1, T2 or T3/T6 configurable by the operator.

T4 list contains :

– 6 timing reference for candidate inputs belonging to the allowable timing reference T1configurable by the operator.

The T0 and T4/T5 lists are used for the management of reference timing source protection; a 1:n protectionlike mechanism is used for the selection of the timing source from T0 (T4/T5) list of the allowable timingreferences, . The protection system chooses the timing reference to generate the output T0 (T4/T5) eitherautomatically, basing on the priority and quality level of the candidate sources according a selectionalgorithm or manually under control of the managing system.

View elements description

Here after, the basic component contained in the synchronization view are described:

• Timing referenceEach allowable timing reference, , is represented by the graphical object displayed in the view;the timing reference graphical object displays (with the exception of Internal Oscillator timingreference) the following information (if the timing source has been declared by the user):

– the name of the selected timing source– the status of the synchronization source: (lockout, manual switch, force switch, automatic

switch, no request, failure)– the label of the quality level of the timing input source– the priority of the timing input source– 2 small boxes representing the SSF (Los) and DRIFT alarms detected on the timing

source;DRIFT means that the Frequency Offset between the external signal source and theinternal clock is high then the maximum tolerance value.SSF means that the Server Signal Failure is sending a wrong reference signal to the NE.In case of alarm indication the operator can select Show Timing Source ( Figure 268. )to visualize the alarm detail.

Page 408: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

360

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

In the timing reference graphical object associated to the Internal Oscillator the followinginformation are displayed :

– the name of the timing source: Internal Oscillator– a small box representing the LOS alarm; the small box will be lighted up when all the

selected timing source are lost, indicating the Holdover or Free Running operation mode;– a label field representing the abnormal clock operation modes; one of the following strings

can be displayed in the label field:• Holdover, displayed when the clock operates in Holdover mode;• Free Running, displayed when the clock operates in Free Running mode• empty string is displayed when the clock operates in Lock

– a label ”0” representing the priority of the Internal Oscillator

• Selectorssmall ellipse are used to represent respectively:– the selector A;– the selector B;– the selector C;

• Squelch Statusboxes contained a label field are used to represent the squelch statuses T0/T4 and T4. The boxdis plays the configured quality level threshold and it is lighted up when the output timing signalis inhibited.

• Output Signalan arrow and a label field are used to represent respectively:– the output signal T0;– the output signal T4/T5;

• line Typethe following different line type are used to link the output signals and the respective allowabletiming reference:– A solid line between an output signal and an allowable timing reference means that timing

reference is currently used to generate that signal;– A dashed line between an output signal and an allowable timing reference means that

timing reference is not currently in use as timing source but will act in the protecting role.In the same way, a solid line between T0 signal and T4/T5 signal (or T0_Test signal) box isdrawn when T0 signal is used to generate T4/T5.

• SSUbox indicating a possible external SSU (Synchronization Source Unit).

• Timing Generatorbox indicating the status of the timing generator .

Page 409: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

361

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.3 Timing Source Configuration

This functionality allows to configure the input synchronization sources and configure or modify the timingsource priority and quality.

Figure 251. Synchronization Menu

The menu options are greyed according to the current state of the dialogue box that the user can open.

Firstly select an empty synchronization source reference and after the Synchronization menu to open theSynchronization Option List (as shown in Figure 251. ). Then select the Timing Source Configurationoption from the cascading menu, as shown in the above figure.

The following dialogue box is opened.

Page 410: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

362

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 252. Timing source configuration for cross–connect equipments

The Timing source configuration dialogue box displays the extracted quality of the selected timing source.It permits to configure the following timing source information:

– Input source– Quality level– Priority level

Click on the Input Source Choice field and then on its related button “Choose“; Figure 253. shows theopened window, to search a TP as a source.

Following the TP Search procedure described in para.14.5.1 on page 217 ( rack, subrack, board, port )enter the termination point (TP) value.The valid TPs for timing reference are : EIS for electrical SDH ports, OpS for optical SDH ports, PPI for2Mb/s ports.

This operation can be repeated for all the available empty synch. sources both for T0 clock and for T4clock.

Page 411: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

363

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 253. TP Synch. source search (example)

Click on the Input Quality Configuration: the option button opens the option menu to select the desiredquality level.

“Input Quality Configuration” can be fixed by the user, in increasing order, with five quality levels: G.811,G.812T, G.812L, G.813, Q. Don’t use (where the highest quality level is G.811 ); or it can be taken as theactual Rx quality, retrieved from the signal received from the line (”Extracted” option).If Input Quality Configuration is set to a value other than ”Extracted”, Rx quality is forced to this value.

Click on the Priority: the option button opens the option menu to select the desired priority level.The internal oscillator timing source will have the lowest priority (priority=0) and its priority can not bechanged. The other timing sources will have a priority of 1 to n.

Priority of 1 is the highest priority. Levels 6,...2 are intermediate levels between level 0 and 1, in increasingorder of priority (i.e. 0 6 5 4 3 2 1).

When the configuration of the timing source is completed, click on the OK push button to validate thechoice and close the dialogue box. The Cancel push button cancels the configuration and closes thedialogue box.

Positioning the mouse on the synch. source box “Port#” test, the corresponding physical interfacedenomination (rack–subrack–board–port) is written on the window bottom left.

Page 412: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

364

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.4 Synchronization Protection Commands

Select the timing reference from the synchronization view. As in Figure 251. , select the Synchronizationpull down menu. You can then select the Protection Commands to open the Figure 254. Menu optionsare greyed according to the current state of the selected timing source.

Figure 254. Lockout, Force and Manual commands

a ) Invoke/Release Lockout: Locking or unlocking a timing source enables or disables the timingsource from being considered as a possible timing source for T0 or T4/T5.

b ) Invoke/Release Force and Manual Selection of Timing Source

General selection

A timing source can be selected manually or automatically. Furthermore, the selection of a particularincoming timing source (except the internal oscillator) may be forced.This selection is independent of the priority or quality of the timing source. If the timing source is lockoutor unavailable, this operation is impossible. A timing source is considered to be available if it is not lockoutand has not a failure condition or Priority level of 0.The forced switch mode is terminated by releasing or inhibiting the force selected timing source.The manual selection option is only possible if the quality and priority of the selected timing source aresufficient. Otherwise the automatic selection algorithm overrules the manual selection.If the previously manual selected timing source becomes unavailable the automatic selection is activated.The “Status” indication describes the current synch. status (No Request, Automatic Switch, Failure, ...)

N.B. The internal oscillator cannot be forced or manually selected.From the dialogue box that opens, you can confirm or cancel the operation.

To perform or release a T0 or T4/T5 lockout, forced or manual selection, the following operations have tobe done:– Select the T0 or T4/T5 source.– Click on the Synchronization menu.– Select the Protection Commands option then invoke/Release the Lockout, Forced or manual

Selection option.– Click on Apply in the displayed confirmation box.

Page 413: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

365

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.5 Synchronization Configuration for T0/T4/T5 and T4 squelch criteria

Select the available T0 or T4 synchronization sources and then the T0 or T4 Configuration... command.This command permits to select/deselect the SSM algorithm, to set the wait time to restore and to enablethe revertive procedure if all these features are available.

In this NE revertive mode is hardware set, with fixed WTR.

In Revertive mode the internal selector A/B (Figure 248. ) changes every time to the best reference clockwith the highest quality; on the same quality level basis the reference clock Source with the best prioritywill be selected. The changing mechanism of the reference inputs is controlled by the wait time to restore:this time sets a delay before to change the input source.

Selecting the T0 or T4 Configuration set the SSM algorithm and the Wait To Restore Time in the dialogbox upper part of Figure 255.

Click on the SSM Algorithm to select/deselect it.

Wait To Restore Time button and Revertive option button are disabled

Selecting Synchronization –> T4 Configuration it is possible to set the T4 “squelch criteria” in the bottomdialog box of Figure 255.

This functionality allows to configure the external timing reference (T4) squelch criteria. The squelchfunction mutes the relevant timing references in the presence of a failure condition.Squelch may be forced by the Operator or according to squelch criteria which consists in a choice of qualitylevel.Different squelch criteria may be applied:

• when T0 is selected to generate T4 (squelch B Figure 248. ): T0 may be squelched if all theallowable timing references of Selector B have Quality Level lower than the programmablethreshold.

• when T1 is selected to generate T4 (squelch A Figure 248. ) :T1 may be squelched if T1 QualityLevel is lower than the programmable threshold or if it becomes unavailable.

The T0/T4 and T1/T4 squelch fields enables the operator to configure the quality level of the T0 or T4timing source, opening the relevant option menu.

When the configuration of T0/T4 Configuration is completed, click on the OK button to validate the choiceand close the dialogue box.

The T5 output field allows to select the bit used (from #4 to #8) for SSM (refer to Figure 256. )

The Cancel button cancels the configuration and closes the dialogue box.

Page 414: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

366

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 255. Configuring the T0 or T4 SSM algorithm and the squelch criteria

Page 415: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

367

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 256. T5 output SSN bits configuration

The T4 squelch configuration dialogue box enables you to configure the quality level of the T4 timingsource.

Click on the T0: option button to open the option menu and select the desired quality level.Click on the T4: option button to open the option menu and select the desired quality level.

The T4 Force Squelch enables you to activate the T4 forced squelch.

When the configuration of T0/T4 Configuration is completed, click on the OK push button to validate thechoice and close the dialogue box.

The Cancel push button cancels the configuration and closes the dialogue box.

Page 416: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

368

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.6 SSU Configuration

The SSU configuration command allows either to configure the single NE or the NE with SSU. In the lastcase the SSU quality has to be defined.SSU: Synchronization Source Unit, it is an external equipment that serves the NE for timing reference.

Selecting SSU Configuration from the Synchronization menu is Figure 257. is presented

Figure 257. SSU Configuration

Page 417: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

369

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.7 Remove Timing Reference

Select the synch. source to remove and click on the Synchronization –> Remove Timing Reference option (Figure 258. ). To remove the selected source click on “OK” button of the confirmation message(Figure 259. ).

Figure 258. Synchronization source removing (example)

To remove the selected source click on “OK” button of the confirmation message (Figure 259. ).

Figure 259. Synchronization source removing confirmation

Page 418: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

370

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.8 Change T4 <–> T5

This option is not applicable to 1640FOX.

This menu allows the change of the synchronization physical interface from 2Mhz (T4 ) to 2 Mbit/s (T5)and viceversa.

NOTE: this menu is enable only if the SERGI board ( on 1650SMC) or SERVICE board (on 1660SM) ispresent in the subrack.

Select Change T4 <–> T5 from the Synchronization menu as shown in Figure 257.

Figure 260. Change T4 <–> T5 menu (example)

A confirmation message appears (see Figure 261. on page 370)

Figure 261. Change T4 <–> T5 confirmation message

Page 419: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

371

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Click on ok to confirm; the new window display T5 instead of T4 (see Figure 262. on page 371)

Figure 262. Change T4 <–> T5: command execution (example)

Page 420: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

372

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.9 Change 2MHz –>2Mbit

This option is not applicable to 1640FOX.

This menu is enabled only if the operator selects a protection unit which have as source a 2 MHz (T3)or a 2 Mbit/s (T6) without traffic.

Select Change 2MHz –>2Mbit from the Synchronization menu as shown in Figure 263.

Figure 263. Change 2MHz –>2Mbit menu (example)

A confirmation message appears (see Figure 264. on page 372)

Figure 264. Change 2MHz –>2Mbit confirmation message

Click on ok to confirm;

Page 421: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

373

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The label of the protection unit will be changed depending on the kind of source selected (see Figure 265. on page 373):

• If the selected protection unit is a 2 MHz, then the label will be changed into 2Mbit/s (2 MbpsT6#A in the example of Figure 265. )

• If the selected protection unit is a 2 Mbit/s, then the label will be changed into 2MHz (2MHz T3#Afor example)

Figure 265. Change 2MHz –>2Mbit: command execution (example)

Page 422: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

374

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.10 Set and Remove T0 Equal T4

To connect T0 internal synch. select a synch. source and click on Synchronization –> Set T0 EqualT4 menu option. The connection between T0/T4 will pass from a shaped to a continue line as in theexample of Figure 266.

Figure 266. T4 equal T0 setting (example)

To separate T4 from T0 click on the “Synchronization –> Remove T0 Equal T4” menu option. The T0/T4connection will become shaped while the connection between T1/T4 will pass from a shaped to acontinue line.

Page 423: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

375

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.11 Transmission of SSM Quality Configuration

Select the T1 SDH Reference Source in the Synchronization View (Figure 250. ) hence the TransmissionSSM Quality Configuration is enabled. This selection allows, with the Inserted option, to transmit thesystem internal T0 clock quality towards the external SDH interface. It is also possible to transmit differentquality level selecting a different value.

Click on Transmitted SSM Quality Configuration of the Synchronization menu option.Figure 267. opens.

Figure 267. Transmission SSM Quality (example)

This Transmission SSM Quality window can be also opened from any SDH boards. Select the Equipmentoption of the View menu, then access the Board view> Port view> Physical Media> SDH Tx QualityConfiguration; it is also possible to open the window selecting the Transmission option of the Viewmenu, then access the Physical Media> SDH Tx Quality Configuration option.

In both cases select the MST block

Page 424: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

376

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

18.2.12 Show Timing Source

Selecting any T1 or T2 Reference Source in the Synchronization View (Figure 250. ) hence the ShowTiming Source is enabled. This selection allows to analyze the input source considering its payloadstructure and the related alarms (Port view is presented) .

Click on Show Timing Source of the Synchronization menu option. Figure 268. opens.

Figure 268. Show Timing Source (example with T2 reference source)

Page 425: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

377

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19 MS–SPRING MANAGEMENT

MS–SPRING is a feature applicable only to 1660SM Equipment; it cannot be applicableto 1640FOX and 1650SMC.

19.1 MS–SPRING introduction

Different MS–SPRING protections architectures are provide: 2–Fiber (Terrestrial), and 4–Fiber NPE(Transoceanic). See ITU–T Rec. G.841.

The description of the MS–SPRING protections is inserted in the Technical Handbook.

4 Fiber MS–SPRING is not operative in this release.

Note for 1660SM Rel. 5.1 only: in the following paragraphs the 2F MS SPRING at STM 16 will beexplained; the same description can be apllied to 2F MS SPRING at STM 64 taking into account that 64AU 4 are available and that the bandwidth is divided into two halves of equal capacity called respectivelyworking (AU4# 1 to AU4# 32) and protection capacity (AU4#33 to AU4# 64).

Page 426: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

378

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.2 MS–SPRING connection configuration advices

In the following paragraphs 2–Fiber advices are reported, to follow before to implement the MS–SPRingprotection: there are some limitations concerning the aggregate types or the AU4s cross–connections tobe considered.

19.2.1 2–Fiber MS–SPRING connection configuration advices

The following suggestions must be considered in the MS SPRING connection configuration:

• SNCP, 4 Fiber MS SPRING and MSP protection connections cannot be installed in a 2 FiberMS–SPRING network. This leads to an unprotected connections installation.

• AU4s from #9 to #16 don’t have to be used for connections nor considered in any parameterof ”Squelching table” provisioning. Only AU4s from #1 to #8 must be used and configured forpath installation.

• AU4 permutation (change of AU4 allocation) is not allowed. The AU4 allocated to pass–throughin HVC connections must be the same through the node.

• AU4 cross–connection line side, i.e. paths received from the line and looped–back to the sameline are not allowed.

• Follow the “Squelching Table Configuration” in order to define the ”Squelching Table HO” forEast and for West Side describing, for each connection installed, as Source Node, the NodeIdentifier of the node generating the considered AU4 and as Destination Node, the NodeIdentifier of the node terminating the AU4.

Page 427: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

379

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.3 Operative sequence to configure MS–SPRING

19.3.1 Operative sequence to configure 2–Fiber MS–SPRING

Next paragraphs list the operative sequence according the type of procedure to obtain.

– Activation procedure

a ) Create an MS–SPRING schema with WTR, Node Identifier, Ring map and the related SquelchingTable for each node of the ring, in the desired order. WTR Ring must be the same in all the nodes.

b ) In the Main dialog for MS–SPRing management select “ACTIVATE” in each node of the ring, in thedesired order.Consider that, in this step, “Default K byte West or East” detection by View Protection StatusParameter (under MS–SPRing label –> “Protocol exception”), will occur on those Ports connectedto the nodes not provisioned yet with the MS–SPRing protection “created” (active).

c ) Verify in the View Protection Status Parameter screen, at the end of the provisioning update, that allthe nodes of the ring are in “MS–SPRing active” and “No request” state.

– Deactivation procedure

a ) In the Main dialog for MS–SPRing management select “DEACTIVATE” in each node of the ring.Consider that, in this step, “Default K byte West or East” detection by View Protection StatusParameter (under MS–SPRing label –> “Protocol exception”), will occur on those Ports of theactivated nodes connected to the nodes just deactivated.

b ) In the Main dialog for MS–SPRing management select “DELETE” in each node of the ring.

– Removing a node

a ) In the Manage ring Map view select the node and click on the”Remove Node” button.

b ) Modify the table in the Configure Squelch Table view according the new Ring Map.

c ) Opening the View Protection Status Parameter screen, send “Force Ring” command to both NE’sadjacent to the node to be removed.

d ) Physically remove the node.

e ) Connect the fibers and send the “Release” command of the relevant “Force Ring” to both NE’sadjacent to the removed node.

– Adding a node

a ) In the Manage ring Map view insert the node in the selected position. Next nodes are automaticallyshifted.

b ) Modify the table in the Configure Squelch Table view according the new Ring Map.c ) Opening the View Protection Status Parameter screen, send “Force Ring” command to both NE’s

adjacent to the node to be added.d ) Physically add the node and configure with 2–Fiber MS–SPRING activated with the right

configuration (Ring Map, Squelching table, WTR, Node Identifier).e ) Connect the fibers and send the “Release” command of the relevant “Force Ring”to both NE’s

adjacent to the added node.

Page 428: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

380

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.4 MS–SPRING Management

In the current release the NE supports the MS–SPRING protection as “Terrestrial architecture“.The Transoceanic application with 4–Fiber is not supported in current release.

For the 2–Fiber Terrestrial application a max. of 16 nodes are available.

The available tables permit to visualize for the same NE the architecture 2 x 2–Fiber.

Figure 269. shows the MS–SPRing pull down menu.

Figure 269. Display MS–SPRing pull down menu

The first Main Dialog for MS–SPRing management option contains all the commands to configure andmanage the MS–SPRing.

In any dialog box is present the Cancel or Close buttons. When the user clicks on these buttons the dialogbox will close without starting any operation.

Page 429: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

381

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.4.1 MS–SPRing Main Configuration

Select the MS–SPRing pull down menu. Then select the Main Dialog for MS–SPRing management option from the pull down menu.

The following dialogue box is displayed (Figure 270. ) when no protection have been previouslyconfigured.

Figure 270. MS–SPRing Management dialogue box.

The only command available is Create. The name of Schema Selection is not editable but is fixed to “NoSchema”.

Click on Create to start the MS–SPRing configuration. Figure 271. opens.

Page 430: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

382

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 271. Creation Schema dialog box.

The user can select the “MS–SPRing Application” and the “Architecture types” supported by the NetworkElement.

Terrestrial MS–SPRing Application is a 2 Fiber architecture.

Transoceanic MS_SPRING is a 4 Fiber architecture (not supported in current release)

The “Port Selection” depends on the Architecture type: if the architecture is a 2F MS–SPRing, the workingand protection port on each side is the same and the “Protecting West and East” fields are disabled(greyed).

If the architecture is a 4F MS–SPRing, the working and protection ports on each side are different.

The label r(xx)sr(y)sl(zz)port#(hh) where r=rack, sr=subrack, sl=slot give the position of the physical port.In the same board it is generally possible to have different port numbers.

The OK button will start the selected operation. The cursor is displayed busy up to receiving a reply. Thenthe dialog window will be closed. Figure 272. opens and all commands are now available.

Page 431: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

383

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 272. Activated MS–SPRing Management

The Holdoff Time command is not operative in current release.

It is possible to give an identification name to the schema by means of the Set Name command (refer toFigure 273. on page 383).

Figure 273. Set scheme name

Page 432: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

384

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Click on Ring Map to configure the network node connection. Figure 274. opens.

Figure 274. Node Id and associated ring node position.

The Ring Map sets the connection sequence of the nodes within the ring. The matrix represents up to 64nodes for transoceanic application and up to 16 nodes for terrestrial application.

Select Current NodeId (it means the NE where the operator is acting) in the box and enable ( � ) ChangeNodeId button (Id means Node Identifier).

Select Available NodeId in the pull down list (0 to 63 for transoceanic application, 0 to 15 for terrestrialapplication) releasing the left mouse button or pushing the stepper arrows and enter keys to select theNodeId value.

This will be displayed in the Available NodeId box then click on Add Node button.

Clicking on the Add Node button the selected “Ring position” will shift one step on the right starting from“1” position and in the “NodeId” field the Available NodeId value is inserted. In the same time the AvailableNodeId will be updated to a new value.

The default association for a four node ring related to the fourth node (NodeId=3; Ring Position=4) isdepicted in Figure 275.

Page 433: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

385

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 275. Ring map configuration

Repeat the procedure for all nodes of the ring selecting the different NEs and edit the different CurrentNodeId value.

To remove a node, select the node and click on Remove Node button. The following Ring Position ofthe nodes on the right decreases by one and the erased NodeId is inserted into Available NodeId , soit can be assigned to other nodes.

The OK button will start the selected operation, displaying the busy cursor up to receiving the reply to theactions. Then the dialog window will be closed.

Click on the WTR button. Figure 276. opens.

Page 434: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

386

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 276. WTR dialog box.

Click on the push mouse button on the up/down Seconds arrows to select the required delay for therelevant WTR. The step value is 60 sec.The range value accepted is from 60 sec. to 900 sec. (in current release is fixed to 300 sec.)

Click on OK to apply the WTR Configuration.

The same WTR Time Ring must be set on each Node of the ring.

Page 435: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

387

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.4.2 Squelching Table with 2 fiber Terrestrial applications

With a 2 fiber Terrestrial application can be selected the Squelching Table while with a 4 fiberTransoceanic application (not supported in current release) can be selected the Ring Traffic (seeFigure 272. on page 383).

If the operator tries to select a different table a error message is visualized. Figure 277. shows the errormessage visualized when is selected the Ring Traffic with a Terrestrial application.

Figure 277. Example of error message

Click on Squelching Table of see Figure 272. on page 383 to configure the AU4 (AU4#1 to AU4#8 for2F Architecture,) connection between the different nodes. Figure 278. opens. The same opens clickingon Configure Squelch Table of the MS–SPRing pull down menu of Figure 269. on page 380.

Figure 278. Squelching table

When the window is opened for the first time the squelching table is N/A ( not available ) because the NEhas never been configured. Point the mouse on the matrix position and click on the right mouse buttonto open the node list menu. Select the node identification number (0 to 15) from the available list usingthe slider or the stepper arrows on the right scroll region.

Page 436: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

388

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.4.2.1 Squelching table example

Figure 279. is an example of ring traffic.

Figure 280. represent in a table the connections of the ring example.

Figure 281. to Figure 288. show how to configure the relative squelching table.

AU4#1

AU4#2

AU4#3

AU4#1

AU4#2

AU4#3AU4#3

West West

WestEast

East East

WestEast

AU4#2 AU4#3

AU4#1

B

CD

A

Figure 279. Example of a ring traffic

The squelching table is applicable only for HO–VC signals.

AU west Node eastNumber

1

2

3

4

5

6

VC

VC

VC

B C DA A

Figure 280. Connections of the ring of Figure 279.

Page 437: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

389

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Node A: 1660SM – MS–SPRING–Squelch Table Configu...

Figure 281. Squelching table of Node A, West side.

Node A: 1660SM – MS–SPRING–Squelch Table Configu...

Figure 282. Squelching table of Node A, East side.

Page 438: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

390

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Node B:1660SM–MS–SPRING–Squelch Table Configu...

Figure 283. Squelching table of Node B, West side.

Node B:1660SM–MS–SPRING–Squelch Table Configu...

Figure 284. Squelching table of Node B, East side.

Page 439: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

391

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Node C:1660SM–MS–SPRING–Squelch Table Configu...

Figure 285. Squelching table of Node C, West side.

Node C:1660SM–MS–SPRING–Squelch Table Configu...

Figure 286. Squelching table of Node C, East side.

Page 440: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

392

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Node D:1660SM–MS–SPRING–Squelch Table Configu...

Figure 287. Squelching table of Node D, West side.

Node D:1660SM–MS–SPRING–Squelch Table Configu...

Figure 288. Squelching table of Node D, East side.

Page 441: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

393

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.4.3 Activate, Deactivate and Delete commands

The Main Activities commands ( Figure 272. on page 383) manage the MS–SPRing configuration. TheMS–SPRing status can be Enable, Active, Disable and Inactive.

After having configured the protection schema by means of the Create button, the status becomes Enable .

The Activate button selection enables the MS–SPRing protection mechanism on the selected schemaconfiguration.

To change from Active to Enable click on the Deactivate button. This command starts the request todeactivate the MS–SPRing protection mechanism.

When the selected protection schema is Enable the Delete button starts the request to remove it. Thedelete action is started after confirming the window message Figure 289. .

Figure 289. Confirmation message

During the activation procedure on different ADMs some of these can be in Active status , others in Inactivestatus. The statuses, the protocol request and the protocol protection errors are described in the chaptersdescribing the“MS–SPRing Protection Status and Commands” .

Page 442: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

394

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.5 MS–SPRING Protection Status and Commands for 2 fiber terrestrialapplication

19.5.1 2F MS–SPRing protection commands

If a protection schema is Active it is possible to select one of the above commands.

Clicking on the Prot. Commands button in the MS–SPRing –>Main Dialog for MS–SPRing management( see Figure 272. on page 383), Figure 290. is opened.

8

Figure 290. Protection states and commands ”Idle” status (2F)

The working/protection span state boxes are not available (greyed) for the 2Fiber MS–SPRingarchitecture.

Page 443: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

395

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

In the MSPRing 2 Fiber configuration, the 1–8 working channels are inserted into the 9–16 protectionchannels in the opposite side of the failure event as shown in Figure 291.

A

E W E

BX w/p

W

Ring Protection:

by the ring protection channels ”p” (AU4 9 to 16)( B on East side )( A on West side )

the working channels (AU4 1 to 8) are substituted

w/p w/p

w/p

Figure 291. Ring Protection (2F)

Page 444: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

396

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.5.2 External commands (2F)

The external protection commands are : Lockout, Force, Exercise (not operative in currentrelease),Manual, WTR.

The lockout commands disable the MS–SPRing management.

The lockout section presents six lockout commands, four operative ( Figure 292. ). Each lockoutcommand is applicable on different points where the lockout actions has to be performed ( Figure 293. )and any “Lockout” command is associated to a “Release “ command to come back to the previous status.

Term “Span” identifies the section interested by the command, it doesn’t assume the Span meaning of thefour fiber protection.

Figure 292. Lockout commands (2F)

Ap

p=protection (AU4 9 to 16) w= working (AU4 1 to 8)

wpw

wp

wp

EastWest

Figure 293. Protection and working channels where the lockout command can be activated (2F)

Page 445: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

397

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The protection events can be equipment/signal failure, signal degrade or external command or acombination of them.

The “Events” will be served if some actions (B/S=bridges and switches) are executed and the networkhas been updated.

The “Events” will be signalled if the K1/K2 protocol communicates to the network nodes what hashappened, without execute actions.

A single ring failure is completely restored but not two ring failures. When are present multiple ring failuresthe automatic B/S protection will try to maintain on all the possible connections.

The K1/K2 communication protocol MS–SPRing is generated from the two nodes adjacent to “Event” viathe protection communication channels. A node is defined tail –end when it firstly receives the “Event”,the second node is defined head–end when it receives back the protocol answer. Figure 294. shows theassociation of tail–end / tail–end or head–end / tail–end.

Some network protection mechanisms are accepted or rejected depending on the end type (tail/head)(lockout command,...)

B

W E W E W E

A C

Tail–end Tail–endTail–end/Head–end

w/p

w/pX X

w/p

w/p

Figure 294. Tail–end / Head–end association

If the node is tail–end, the lockout working ring command disable the protection MS–SPRingmechanisms, while if the node is head–end, it serves the request node protection (protection notdisable). See Figure 295. on page 398.

With the lockout protecting span command and a ring failure, the ring protection is served if this ring failureoccurred along the same section; the ring protection is disabled if the ring failure has occurred inanother ring section.On the contrary, with the lockout working ring command failure and a ring failure along a different section,the ring protection is served ((protection not disable). See Figure 296.

Page 446: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

398

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

W E

W

E

A

B

Lockout working

w/p

w/p

failure

ring protection

W E

W

E

A

B

Lockout workingw/p

w/p

failure

no ring protection

tail

head

tail

head

Figure 295. Tail–end / head–end protection with a lockout working and a one direction ring failure (2F)

Page 447: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

399

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

W EW

E

A

B

Lockout protecting Span

w/p

w/p

failure

ring protection

W

A

Lockout protecting Span

failure

no ring protection

W

E

C

W EW

E

A

B

w/p

w/p

failure

w/p

w/p

ring protection

W

A

failure

W

E

C

w/p

w/p

W EW

E

A

B

w/p

w/p

failure

no ring protection

ring protection

E

E

Lockout working Lockout working Lockout working

Lockout working

Figure 296. Ring protection with a lockout and a ring failure (2F)

Page 448: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

400

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 297. shows a ring with three nodes and the actions performed by the lockout commands. Thiscommand disables the acknowledgment of the signal failure/degrade on the receiving ports.

A N

od

e

B

WE

WE

WE

AC

A N

od

eA

No

de

A N

od

e

Rin

g E

Lo

cko

ut

Pro

tect

ion

Rin

g W

Lo

cko

ut

Pro

tect

ion

Rin

g E

failu

res

and

of

no

n–s

erve

d”1

” ”2

Lo

cko

ut

Wo

rkin

g

Rin

g W

Lo

cko

ut

Wo

rkin

g

1

2

4

ring

prot

ectio

n on

the

oppo

site

sid

eth

e op

posi

te s

ide

if th

e rin

g fa

ilure

if

the

ring

failu

reoc

curs

bet

wee

nA

–C o

r C

–B n

odes

occu

rs b

etw

een

A–B

or

B–C

nod

es

ring

prot

ectio

n on

Com

bina

tions

exte

rnal

com

man

ds

3w

/p

w/p

w/p

w/p

Figure 297. Lockout command and non–served failures (2F)

Page 449: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

401

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The Force command ( Figure 298. ) executes a forced protection. The Force Ring command substitutesthe working channels (AU4 1 to 8) with the opposite direction protection channels (AU4 9 to 16) betweentwo adjacent nodes (Figure 299. ).The Force Span command is not operative in 2 fiber MS–SPring.

Figure 298. Forced and Manual commands (2F)

AEW

w1–8

Manual/force Ring East

BW E

W. 1–8 channels are substituted by P. 9–16 channelson the opposite side for both adjacent nodes

A1

w1–8

w1–8

p9–16

w1–8

p9–16

p9–16

p9–16

w1–8

p9–16

w1–8

p9–16

W/P

W/P

B1

w1–8

p9–16

w1–8

p9–16

W/P

Manual/force Ring West

Figure 299. Manual and Force Ring command (2F)

The Manual command is similar to Force command but it is at a lower priority level with respect toautomatic MS–SPRing. The general priority scale that can be applied to solve antithetical situationsstarting from the lowest priority level is: manual ring – automatic working ring – force ring – lockoutWorking Ring – lockout Protecting Span.

When a force ring command is applied a next working failure is not able to modify the forced configurationapplied. That is because force ring command has a higher priority respect to the “Automatic” workingprotection. In this condition the ring can be split according the location of command and event. Vice versathe “Manual” protection is exceeded by the “Automatic” protection. Figure 300. visualizes the ringprotection with a Force/Manual command and a signal failure. FS–R is for “Force Switching Request”,SF–R is for “Signal Failure Request”.

Page 450: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

402

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

W E

W

E

A

B

Force Ring East

w/p

w/p

failure

W

A

failure

ring protection for FS–R

W

E

C

W E

W

E

A

B

w/p

w/p

failure

w/p

w/p

ring protection for SF–R

W

A

failure

W

E

C

w/p

w/p

ring protection for SF–R

Force Ring East

Manual Ring East

W

E

C

BW

E

CW

E

”A” node is isolated

E

Manual Ring East

E

ring protection for SF–R and FS–R

Figure 300. Ring Protection with Force and Manual commands (2F)

Page 451: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

403

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

A node

Signal fail/degrade

A node

B/S actions

Ring WSignal fail/degrade

Ring E

1–2 w. channels aresobstituted by 3–4 p.

3–4 w. channels are

B

W E W E W E

A C

w/p1

2w/pw/p

w/p

3

4

sobstituted by 1–2 p.channels channels

Figure 301. Automatic protection Bridge/Switch (2F)

Each command starts when the proper button is selected. A dialog box ( Figure 302. ) has to be confirmedbefore the command is performed.

From each command exists its own Release button to cancel the previously selected command and comeback to normal MS–SPRing protection.

Figure 302. Example of confirmation dialog box

Clicking on the WTR command (of Figure 272. on page 383) next figure opens. If the WTR box, in theLocal Condition field of Figure 290. on page 394, becomes red a waiting time has been activated afterrepairing the ring failure. The waiting time, set in the configuration menu, can be cleared selecting theClear WTR Ring command. A confirmation dialog box opens and, if the operator clicks OK, the WTRbox turns off and the protection status window is updated.

Figure 303. Clear WTR command (2F)

Page 452: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

404

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.5.3 2F MS–SPRing dual protection commands

In general dual contemporary “Events” can be:

two external commands

an external command and a ring failure

two contemporary ring failures

Dual “Events” can appear on the same side W/W (West/West) or E/E (East/East) (SS= same side) or onthe opposite side W/E or E/W (OS= opposite site) of the ring network. In the SS or OS the “Events” canappear on the same node (SN) or on the different nodes (DN), the different node can be an adjacent node(AN) or a remote node (RN). Figure 304. depicts a clockwise ring network . The network propagationK1–K2 protocol signals are according to the following legend :

C = served the column element

R = served the row element

B = served both row and column elements

Cs = signalled (not served) the column element

Rs = signalled (not served) the row element

Bs = signalled (not served) both row and column element

when a command (Manual switch, Force switch) is neither served nor signalled, it is erased ( it isnot pending at the node)

Page 453: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

405

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

W E

W

E

1

2

w/p

w/p

w/p

w/p

WE

3

W

E

4

Reference point

SS SNclockwise

OS AN

SS AN

OS SN

OS RNSS RN

SS RN

OS RN

Figure 304. Ring network reference scheme (2F)

Figure 304. visualizes the ring reference scheme: the adjacent node (AN) is the node connected to thereference point.

The automatic protection for dual ring failures is represented in Figure 306. Consider the networkreference scheme of Figure 305. with a tail–end / head–end alarm propagation. In this figure are depictedthe node switches for any reported double events.

Page 454: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

406

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

W EW

E

1

2

w/p

w/p

failure

W

E4

failureWE

3

W EW

E

1

2

w/p

w/p

failure

W

E4

failure

WE

3

W EW

E

1

2

w/p

w/p

failure

W

E4

failure

WE

3

W E W

E

1

2

w/p

w/p

failure

W

E4

failure

WE

3

W EW

E

1

2

w/p

w/p

failure

W

E4

failure

WE

3

SS–AN

SS–RN

OS–AN

OS–RN

OS–SN

Figure 305. Examples of Double ring failure

Page 455: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

407

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Rin

gP

rote

ctio

n

point

Otherpoints

SN

AN

RN

SN

AN

RN

Reference

Au

tom

atic

SS

OS

Automatic Protection Ring

Nodes 1,2,3,4 in switching for SF alarm =B

Node 4=intermediate

Node 2: isolated=BsNode 1,3 in switching for SF alarm=BNode 4 = intermediate

Node 1,2 in switching for alarm=BNodes 3,4 = intermediate

Node 1: isolated=BsNodes 2,4 in switching for SF alarm=BNode 3= intermediate

Node 2 : isolated = BsNode 1–3 in switching for SF alarm =B

Figure 306. 2F Automatic protection (tail/head) for double ring failure visualization

The same reference Figure 304. and Figure 305. schemas are applied to describe dual generic “Events”where both ring failures and external commands are considered.

The first row at the top of the protection table (Figure 307. ) shows the “Events” at the reference point. Foreach of them the associated “Event” is listed on the first column at the left of the table.

Two manual ring commands can be only signalled: Bs (Manual SS–SN and OS–AN commands give thesame ring protection switching and then both can be served).

Two Lockout commands are both always served: B

Force command has priority with respect to the Manual one.

Automatic protection has priority with respect to the Manual command.

Force Ring and Automatic Protection (or two Force ring commands) are always served if they are notapplied on the SS–SN. In this last case has to be considered the priority level. The behavior is that seenfor two automatic protection switching ( Figure 305. )

Lockout working SS–SN has priority with respect to Manual, Automatic protection and Force commands.In the other cases, both commands are served (B).

Lockout protection SS–SN / OS–AN and Manual or Automatic or Force command are both servedbecause the switching SS–SN / OS–AN channels are not managed by the lockout protection: B.

Lockout protection SS–AN / OS–SN overrides the Manual or Automatic or Force command because thelockout protection controls the switching channels of the same Node.

Lockout protection SS–RN / OS–RN and manual or automatic or force command: the lockout protectionprevents the working 1–8 channels from being inserted into the protecting 9–16 ones. The lockoutprotection is served, because it has a higher priority, the ring protection will be only signalled (pending).

Page 456: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

408

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Rin

g

Ring

Manual

Ring

Automatic

Ring

ForceF

orc

eR

ing

Man

ual

LockoutWorking

Protection Working

SS

OS

SN

SS

OS

SN

SS

OSSN

AN

RN

AN

RN

AN

RN

SS

OS

SN

AN

RN

Lo

cko

ut

Wo

rkin

gL

ock

ou

t Pro

tect

ing

SN

RN

AN

SN

AN

RN

SN

AN

RN

SN

AN

RN

Bs

BsBs

B

BsCCC

CCCCBBBBBBC

CRsC

CRsB

point

Otherpoints

Reference

RR

RRR

R

RR

RRR

R

CBBBBB

CBBBBB

CBBBBB

BBBBB

BC

CRsC

CRsB

BC

CRsC

CRsB

B

B

BR

RCsRB

RCsBRRCs

RBRCs

RB

BB

B

B

RBBBBB

Figure 307. Tail / head dual “Events” Protection table (2F)

Page 457: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

409

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.5.4 2F Protection Status Visualization

The protection statuses ring network are:

– 1 – Lockout Switching

– 2 – Forced Switching

– 3 – Automatic Switching ( MS–MSPRing protection for equipment/signal failure ).

– 4 – Manual Switching

– 5 – Idle ( regular operation without MS–SPRing protection )

These protection states are represented with the following color state boxes:

– Green: Active State, No Request condition.

– Red: Inactive State and any external or protection executed command ( that has been served ).

– Yellow: ordered but not executed command ( that has only been signalled= pending status ).

– Greyed: not available state box.

Automatic switching and external commands are revertive: then when the “Events” have been cleared,the MS–SPRing configuration comes back to its idle status.

The state boxes visualize the “Node Condition Request” as a consequence of the equipment/signal failureor the external commands detected on the corresponding side (”Event”). The state boxes don’t describethe protection actions provided on the NEs.

The served “Events” ( B/S=bridges and switches are executed and the network has been updated ) arecompleted B/S actions visualized as red box indications

The signalled “Events” ( the K1/K2 protocol communicates to the network nodes what has happened )are pending B/S visualized as yellow box indications.

Figure 308. shows the protection status with a served East manual ring command. Any protection statuswindow is divided in different status fields: Schema description and status, Local Conditions, NodeConditions and Protocol Exceptions. The first one describes the network configuration and applicationtype and its status, the second gives the local external commands indications, the third the “Events” resultson the nodes and the fourth one checks the k1/k2 ring protocol. The window is divided into three parts:West, Middle and East. On the West there are all the box indications corresponding to the West protectionsand commands. In the middle “WTR–Ring” refers to West and East sides, “No Request” correspondingto “Idle Status”, and “Intermediate Node” denotes that the protections and commands don’t concern thenode involved. The Manual Ring command visualizes “Manual Ring” on the local node and “RequestNode Ring” in the both “Local Conditions adjacent East ADM1–West ADM2 nodes, while the 3 and 4nodes are “Intermediate Node”. The red color means that the command has been served. A regularprotocol “Exceptions” is represented with white boxes, a protocol alarm is signalled with red boxes. The“Prot. Unavailable” indications are activated when a lockout protection command is applied in a networknode.

Page 458: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

410

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 308. Manual command applied at the “Reference Point” ring network Figure 305.

Figure 309. reports the “Protection Status” for external “Force and “Manual” commands in a 3 –node ring(A, B, C). Figure 310. shows the lockout statuses and Figure 311. the automatic protection statuses.

Page 459: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

411

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Local Conditions Force/

WRing

A

Force/Manual Force/Manual

B C A B C

Node ConditionsNode

WRing

RequestNode

ERing

Request

Nod

e

Inte

rmed

iate

Force/

ERing

Node

ERing

RequestNode

WRing

Request

Nod

e

Inte

rmed

iate

B

W E W E W E

A C

w/p

w/p

w/p

w/p

Ring W Ring E

Manual Manual

Referencenode: A

Figure 309. Visualization of the Forced / Manual protection Statuses (2F)

Page 460: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

412

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LocalRing W

A

Lockout Working Lockout Protecting

B C A B C A B C A B C

Node

Ring E

Nod

eIn

term

edia

te

Nod

eIn

term

edia

te

Ring W Span W Span ELockout Working

Ring ELockout Protecting

Lockout Lockout LockoutProt W

LockoutProt E

Referencenode: A

Pro

t. U

nava

ilabl

e

Pro

t. U

nava

ilabl

e

Pro

t. U

nava

ilabl

e

Pro

t. U

nava

ilabl

e

B

W E W E W E

A C

w/p

w/p

w/p

w/p

Conditions

Conditions

Figure 310. Visualization of the Lockout command Statuses (2F)

Page 461: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

413

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

A

Signal fail/degrade

B C A B C

Node Conditions

Ring WSignal fail/degrade

Ring E

WRing

Request

ERing

Request

Nod

e

Inte

rmed

iate

WRing

Request

ERing

Request

Nod

e

Inte

rmed

iate

Referencenode: A

B

W E W E W E

A C

w/p

w/p

w/p

w/p

Figure 311. Visualization of Automatic Protection Statuses (2F)

The WTR status is visualized on the side where the link has been repaired. The considered networkfailures are related to a tail–end/head–end node connection. The “WTR Clear” command can be executedby the user without waiting the WTR setting time.

Page 462: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

414

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.5.4.1 Double ring failure

The double ring failure visualization of Figure 305. are here following reported.

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 312. Protection status with double ring failure (reference point––SS–AN)

Figure 312. reports the protection status with double ring failure (reference point––SS–AN. The node 2isolated, the nodes 2–3 in switching and the node 4 Intermediate. The box color is white unless otherwisespecified:

“Active”: green“Request Node Ring” West ADM3–East ADM1: red (served)“Request Node Ring” West ADM2–East ADM2: yellow (pending)“Intermediate Node” ADM4: red

Page 463: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

415

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 313. Protection status with double ring failure (reference point––SS–RN)

Figure 313. reports the protection status with double ring failure (reference point––SS–RN). The nodes1,2,3,4 are being switched for signal failure alarm and both the two signal failures are served. The boxcolor is white unless otherwise specified:

“Active”: green“Request Node Ring” East ADM3–East ADM1: red (switching for SF)“Request Node Ring” East ADM4–East ADM2: red (switching of the opposite nodes)

Page 464: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

416

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 314. Protection status with double ring failure (reference point––OS–AN)

Figure 314. reports the protection status with double ring failure (reference point––OS–AN). The nodes1,2 are being switched for signal failure alarm and both signal failures are served: B. The box color is whiteunless otherwise specified:

“Active”: green“Request Node Ring” West ADM2–East ADM1: red (switching for SF)“Intermediate Node ” ADM3–ADM4: red

Page 465: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

417

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 315. Protection status with double ring failure (reference point––OS–AN) recovering to “idle”

Figure 315. reports the previous protection status with double ring failure (reference point––OS–AN)while the ring protection comes back to its “idle” status. The “WTR (Wait To Restore) Ring” on ADM1 nodebecomes red to signal that the SF disappears at the “reference point” . The box color is white unlessotherwise specified:

“Active”: green“WTR Ring” : red (to signal the SF recovering)“Request Node Ring” West ADM2–East ADM1: red“Intermediate Node ” ADM3–ADM4: red

Page 466: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

418

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

19.5.4.2 Double external command or an external command and a ring failure

Some more significative double events of Figure 307. are here following reported.ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 316. Double manual ring command (reference point––SS–AN)

Figure 316. reports the protection status with double manual command (reference point––SS–AN). Boththe commands can be only pending. The “Request ring” to 1,2,3 nodes becomes pending while the 4 nodeis “Intermediate node”. The box color is white unless otherwise specified:

“Active”: green“Request Node Ring” East ADM1– West ADM2: yellow ( pending ) for Manual Ring East ADM1“Request Node Ring” East ADM2– West ADM3: yellow ( pending ) for Manual Ring East ADM2“Request Node Ring” West ADM1– East ADM3: yellow ( pending ) for switching of the opposite nodes“Intermediate Node ” ADM4: red

Page 467: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

419

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 317. Double manual ring command (reference point––OS–AN)

Figure 317. reports the protection status with double manual command (reference point––OS–AN). Boththe commands can be served. The “Request Manual ring” to ADM1 (East) and to ADM2 opposite side(West) collapses in the same manual command. Both the manual commands are served. The box coloris white unless otherwise specified:

“Active”: green“Request Node Ring” East ADM1– West ADM2: red ( served )“Intermediate Node ” ADM3, ADM4: red

Page 468: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

420

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 318. Manual ring and Lockout Protection (reference point––SS–SN)

Figure 318. reports the protection status with a manual command and a lockout protection (referencepoint––SS–SN). Both the manual and the lockout commands are visualized to the same ADM1 node(East). Both the commands are served because the bridge/switch points are different. The box color iswhite unless otherwise specified:

“Active”: green“Request Node Ring” East ADM1 – West ADM2: red ( served )“Intermediate Node ” ADM3, ADM4: red“Manual Ring and Lockout Prot.” commands East ADM1: red“Prot. Unavailable” East ADM1 : red .N.B. The “Prot. Unavailable” is not propagated on West ADM2 node because on West ADM2 the

protection switching has been executed.

Page 469: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

421

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 319. Manual ring and Lockout Protection (reference point––SS–RN)

Figure 319. reports the protection status with a manual command and a lockout protection (referencepoint––SS–RN). The manual command is pending while the lockout command is served. The box coloris white unless otherwise specified:

“Active”: green“Manual Ring” command East ADM1: yellow“Request Node Ring” East ADM1 – West ADM2 : yellow ( pending )“Request Node Ring” West ADM1 – East ADM2 : yellow ( pending ) for switching of the opposite nodes“Lockout Prot.” command: East ADM3 : red“Prot. Unavailable” East ADM3 and West ADM4: red (served)

Page 470: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

422

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 320. Automatic working ring and Manual Ring (reference point––OS–AN)

Figure 320. reports the protection status with a ring failure and a manual ring command (referencepoint––OS–AN). The automatic protection has a higher priority with respect to the manual command andthen it has been served. The box color is white unless otherwise specified:

“Active”: green“Request Node Ring” East ADM1 – West ADM2 : red (served)“Intermediate Node” ADM3 – ADM4 : red

Page 471: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

423

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 321. Automatic working ring and Force Ring (reference point––SS–AN)

Figure 321. reports the protection status with a ring failure and a force ring command (referencepoint––SS–AN). The ADM2 is isolated and the force command is pending. The box color is white unlessotherwise specified:

“Active”: green“Request Node Ring” East ADM1: red (served) the West ADM1 switching is applied for SF“Request Node Ring” West ADM3: red (served) the East ADM3 switching is applied for the force command“Request Node Ring” West ADM2, East ADM2: yellow (pending) the ADM2 is isolated“Intermediate Node” ADM4 : red

Page 472: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

424

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 322. Automatic working ring and Lockout working Ring (reference point––SS–SN)

Figure 322. reports the protection status with a ring failure and a lockout working command (referencepoint––SS–SN). The Lockout command has a higher priority with respect to the automatic protectionswitching and then only the lockout command has been served. The box color is white unless otherwisespecified:

“Active”: green“Lockout Ring” command East ADM1: red“Request Node Ring” East ADM1 – West ADM2 : red (served)“Intermediate Node” ADM3 – ADM4 : red

Page 473: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

425

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

ADM4: 1660SM –– MS–SPRING–Protection States and Commands ADM1: 1660SM –– MS–SPRING–Protection States and Commands

ADM3: 1660SM –– MS–SPRING–Protection States and Commands ADM2: 1660SM –– MS–SPRING–Protection States and Commands

Figure 323. Automatic working ring and Lockout Protection (reference point––OS–RN)

The lockout protection has a higher priority with respect to the automatic ring protection. The box coloris white unless otherwise specified:

“Active”: green“Lockout Prot.” command West ADM3: red“Prot. Unavailable” West ADM3 – East ADM2 : red (lockout protection is served)“Request Node Ring” East ADM1 – West ADM2 : yellow (automatic protection is pending)“Intermediate Node” ADM4 : red

Page 474: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

426

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Page 475: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

427

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

20 ISA PORT CONFIGURATION

20.1 Introduction

This Chapter describes the operations necessary for the ISA boards creation (ATM, PR_EA, PR,ETHERNET, ES) in the Equipment view and the ISA TTPs creation; as a matter of fact ISA boards doesnot crate TTPs when they are configurated.

The ISA board creation is performed (following the same rules of all the other SDH/PDH ports asexplained in paragraph 9.2 on page 122) when a CT user sets an ISA board and then configure the IPAddress (as described in paragraph 8.14 on page 110).

For the TTPs creation refer to paragraph 20.2 where all the operation are explained.

For the ISA traffic configuration (for example creation of Hard/Soft cross connection, PNNI configurationetc.) refer to the relevant OPERATOR’S HANDBOOK (ATM, PR, PR_EA or ES) where “Specific Terminal”application is explained in details.

The operational sequence to follow to manage ISA cross–connection is:

a ) ISA board declaration (Equipment Set)

b ) ISA IP Address Configuration ( Called ISA board IP Address) (not needed for ISA–PR andETHERNET boards)

c ) ISA board TTPs creation (VC4XV , VC12XV, VC3XV, VC4–4c TTP, VC4 TTP, VC3 TTP, VC12 TTP,s31 TTP, E1 TTP) (not needed for ISA–PR board)

d ) TTPs cross–connection ( refer to paragraph 15.3 on page 270) (not for ISA–PR board)

e ) ISA traffic configuration with “Specific Terminal” application

Page 476: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

428

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

20.2 ISA board TTPs creation

In the following paragraphs will be explained how to create, delete and modify ISA board TTPs.

20.2.1 ISA–ATM boards

On the ATM 4X4 board can be configurated up to 16 TPs (VC4 TTP, VC3 TTP, VC12 TTP, s31 TTP, E1TTP) with a maximum throughput of 622 Mbit/s.

On the ATM 4X4 V2 board can be configurated up to 252 TPs (E1 TTP, E3 TTP, VC12 TTP, VC3 TTP, VC4TTP, T3 TTP) with a maximum throughput of 622 Mbit/s.

On the ATM 8X8 board (present only on 1660SM) can be configurated up to 32 TPs (VC4–4c TTP, VC4TTP, VC3 TTP, VC12 TTP, s31 TTP, E1 TTP) with a maximum throughput of 1.2 Gbit/s.

Select ISA Port Configuration option from the Configuration menu to open the ISA ports Configuration(see Figure 324. on page 428).

ATM 4X4 MATRIX (with defined TPs)ATM 4X4 MATRIX (initial empty fields)

Figure 324. ATM TPs creation

The ISA ports Configuration window is filled with notebook pages (initially blank), each page is an ATM,Ethernet or PR_EA board with relevant ports;

The user can “create” a new port, “delete” an existing one and “change” port associations (that meansmodify the STM1 number and STM–1 Time Slot on ISA ports already created) via the three buttonscontained in the notebook page.

When the user want to create a new ATM port he can select an empty row, then in the “Selected Item”sections , he can fill the field ”Signal” choosing among the available options and push the”Create” button.

The STM1 Number and the STM1 Time Slot are automatically assigned.

If the user want to change the port attribute association he can select a filled row, then in the “SelectedItem” section he can change the fields ”STM1 number” and ”STM1 Time Slot” and than push the ”TimeSlot Sw.” button.

Page 477: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

429

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

To delete a port the user can select a row and push ”Delete” button.

To close the dialog box click on the “Close” push button.

It is possible to see the ATM Ports created as above explained by selecting the relevant row in the ISAconfiguration window and then click on the “Navigate” button; Figure 325. on page Figure 325. showsan example.

LCA

Figure 325. Navigate to ATM port view (example)

Page 478: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

430

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

20.2.2 ISA– PR_EA board

On the PR_EA boards can be configurated the following TPs:

– PREA4ETH: up to 59 TPs (SDH VC4, SDH VC3, SDH VC12 ) with a maximum throughput of 622Mbit/s.

– PREA1GBE: up to 62 TPs (SDH VC4, SDH VC3, SDH VC12 ) with a maximum throughput of 622Mbit/s.

Select ISA Port Configuration option from the Configuration menu to open the ISA ports Configuration(see Figure 326. on page 430).

PR_EA MATRIX (with defined TPs)PR_EA MATRIX (initial empty fields)

Figure 326. PREA4ETH: example of TPs creation

The ISA ports Configuration window is filled with notebook pages (initially blank), each page is an ATM,Ethernet or PR_EA board with relevant ports;

The user can “create” a new port, “delete” an existing one and “change” port associations (that meansmodify the STM1 number and STM–1 Time Slot on ISA ports already created) via the three buttonscontained in the notebook page.

When the user want to create a new PR_EA port he can select an empty row, then in the “Selected Item”sections , he can fill the field ”Signal” choosing among the available options and push the”Create” button.

The STM1 Number and the STM1 Time Slot are automatically assigned.

If the user want to change the port attribute association he can select a filled row, then in the “SelectedItem” section he can change the fields ”STM1 number” and ”STM1 Time Slot” and than push the ”TimeSlot Sw.” button.

To delete a port the user can select a row and push ”Delete” button.

To close the dialog box click on the “Close” push button.

Page 479: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

431

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

It is possible to see the PR_EA Ports created as above explained by selecting the relevant row in the ISAconfiguration window and then click on the “Navigate” button; Figure 327. on page 431 shows anexample.

LCA

Figure 327. MPLS port view exaple

Page 480: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

432

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

20.2.3 10/100 Mbit/s fast ETHERNET board

On the FAST ETHERNET boards can be configurated up to 11 TPs (VC4 TTP, VC3 TTP, VC12 TTP,VC12XV and VC3XV) on the port card (ETH–MB) and up 14 TPs (VC4 TTP, VC3 TTP, VC12 TTP, VC12XVand VC3XV) on the relevant access card (ETH–ATX).

Select ISA Port Configuration option from the Configuration menu to open the ISA ports Configuration(see Figure 328. on page 432).

ETH–MB (with defined TPs)ETH–MB (initial empty fieds)

Figure 328. Example of Fast Ethernet (ETH–MB) TPs creation

The ISA ports Configuration window is filled with notebook pages (initially blank), each page is an ATM,Ethernet or PR_EA board with relevant ports;

The user can “create” a new port, “delete” an existing one and “change” port associations (that meansmodify the STM1 number and STM–1 Time Slot on ISA ports already created) via the three buttonscontained in the notebook page.

When the user want to create a new TPs he can select an empty row, then in the “Selected Item” sections,he can fill the field ”Signal” choosing among the available options and push the”Create” button.Note: in case of concatenated VC TP creation (example VC12XV or VC3XV), before to push on ”Create”button it is also necessary to choose the Concatenation Level value; after creation command new fieldsand a new button appear.

The STM1 Number and the STM1 Time Slot are automatically assigned.

If the user want to change the port attribute association he can select a filled row, then in the “SelectedItem” section he can change the fields ”STM1 number” and ”STM1 Time Slot” and than push the ”TimeSlot Sw.” button.

The Ctrl Path Act. button allows to change the state of the concatenated virtual VCs (example VC12XVor VC3XV) that could be “Idle” or “active”.;

Click on Ctrl Path Act. button a new window will be opened (Figure 329. ); for details about the meningof the field refer to paragraph 11.7.8 on page 165.

Page 481: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

433

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

To delete a port the user can select a row and push ”Delete” button.

To close the dialog box click on the “Close” push button.

Figure 329. Control Path activation window (example)

It is possible to see the VCs created on the ETHERNET board as above explained by selecting therelevant row in the ISA configuration window and then click on the “Navigate” button; Figure 330. onpage 433 shows an example.

LCA

Figure 330. ETHERNET port view example

Page 482: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

434

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

20.2.4 Gigabit/s ETHERNET board

Two architectures are possible to provide Gigabit Ethernet ports:

[1] 10/100Mbit/s Ethernet board (ETH–MB)+GBIT Access (GETH–AG); this feature is supported onlyon 1650SMC and 1660SM.

With this architecture can be configurated up to 2 TPs (VC4XV TTP Type concatenation level=1) onthe GETH–AG access card and up to 11 TPs (VC4 TTP, VC3 TTP, VC12 TTP, s31 TTP, E1 TTP Type)on the ETH–MB main board taking into account that the maximum throughput must not exceed 622Mbit/s.

[2] GIGABIT board (GETHMB) stand–alone; this feature is supported on all OMSN (1640FOX,1650SMC and 1660SM).

With this architecture can be configurated up to 4 TPs (VC4XV Type) on each board taking intoaccount that the maximum throughput must not exceed 622 Mbit/s in 1640FOX and 1650SMC (forexample it is possible to configure 1 port VC4XV with a max. concatenation level equal to 4 or asalternative 4 ports VC4XV with concatenation level equal to 1).

The same rule above described are applicable to 1660SM when the GIGABIT board (GETHMB)is equipped in normal slot (i.e. slot with a throughput of 622 Mbit/s).In 1660SM are also available slot called “enhanced” (25, 26,28,29,34,35,37,38) where thethroughput per board is 1.2 Gbit/s.If the GIGABIT board (GETHMB) is equipped in one of these slot it is possible to reach a max.concatenation level equal to 7 per port ; of course this means that there is only one VC4XV withconcatenation level =1 available for another port and no resources for the last two ports present onthe board.For more details read the Gigabit Ethernet description reported in the Technical Handbook.

The Gigabit Ethernet TPs creation follows the same rules described for the 10/100Mbit/s Ethernet Board;refer to paragraph 20.2.3.

Page 483: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

435

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

20.2.5 ISA –ES boards

On the ETHERNET SWITCH boards can be configurated the following Tps:

– On the ISA ES1–8FE up to 8 among VC4 TTP, VC3 TTP, VC12 TTP, VC12XV (XMAX= 21), VC3XV(XMAX= 2)

– On the ISA ES1–8FX up to 8 among VC4 TTP, VC3 TTP, VC12 TTP, VC12XV (XMAX= 21), VC3XV(XMAX= 2)

– According to the settings made in the Equipment Set procedure (SMII or GMII), the board ISAES4–8FE can be configured with the following TPs:

• ISA ES4–8FE SMII mode: up to 16 TPs among VC4 TTP, VC3 TTP, VC12 TTP, VC12XV(XMAX= 50), VC3XV (XMAX= 2), VC4XV (Xmax=1).

• SA ES4–8FE GMII mode: up to 2 TPs among VC4 TTP, VC3 TTP, VC12 TTP, VC12XV (XMAX=63), VC3XV (XMAX= 12), VC4XV (Xmax=4).

– On the ISA ES16 (not available on 1640FOX) up to 16 among VC4 TTP, VC3 TTP, VC12 TTP,VC12XV (XMAX= 63), VC3XV (XMAX= 12) , VC4XV (XMAX= 8)

Select ISA Port Configuration option from the Configuration menu to open the ISA ports Configuration(see Figure 332. on page 436).

Figure 331. Example of Ethernet Switch (ES1–8FE) TPs creation (EMPTY FIELDS)

Page 484: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

436

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Figure 332. Example of Ethernet Switch (ES1–8FE) TPs creation (WITH DEFEINED TPS)

The ISA ports Configuration window is filled with notebook pages (initially blank), each page is an ES, ATMor PR_EA board with relevant ports;

The user can “create” a new port, “delete” an existing one and “change” port associations (that meansmodify the STM1 number and STM–1 Time Slot on ISA ports already created) via the buttons containedin the notebook page.

When the user want to create a new TPs he can select an empty row, then in the “Selected Item” sections,he can fill the field ”Signal” choosing among the available options and push the”Create” button.Note: in case of concatenated VC TP creation (example VC12XV or VC3XV), before to push on ”Create”button it is also necessary to choose the Concatenation Level value; after creation command new fieldsand a new button appear.

The STM1 Number and the STM1 Time Slot are automatically assigned.

If the user want to change the port attribute association he can select a filled row, then in the “SelectedItem” section he can change the fields ”STM1 number” and ”STM1 Time Slot” and than push the ”TimeSlot Sw.” button.

Page 485: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

437

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The LCAS Cfg.. button allows to Enable / Disable the LCAS scheme protocol selecting the relevant button(refer to paragraph 11.7.9 on page 167).

The Ctrl Path Act. button allows to change the state of the concatenated virtual VCs (example VC12XVor VC3XV) that could be “Idle” or “active”.;

Click on Ctrl Path Act. button a new window will be opened (Figure 329. ); for details about the meningof the field refer to paragraph 11.7.8 on page 165.

To delete a port the user can select a row and push ”Delete” button.

To close the dialog box click on the “Close” push button.

Figure 333. Control Path activation window (example)

It is possible to see the VCs created on the ETHERNET SWITCH board as above explained by selectingthe relevant row in the ISA configuration window and then click on the “Navigate” button; Figure 330. on page 433 shows an example.

Page 486: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

438

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

LCA

Figure 334. ETHERNET SWITCH port view example

Page 487: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

439

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

21 SOFTWARE MANAGEMENT

21.1 Generalities and descriptions

The Craft Terminal provides a set of functions which allow software packages manipulation within NEs.The downloading operation consists in the establishment of session between the NE and a softwareserver for the purpose of file transfer.

Actions can then be performed on the NE software version as update and activation operation, or roll backto the previous software version operation. In this way the NE can follow the product evolution with “inservice” equipment.The same function is used during maintenance phase, to update spare boards for substitution aftertroubleshooting.

The operations that can be undertaken in this section are:

– display Software Download Information,– initiate / Abort Software Package Download,– manage Software Packages within NEs, activating the downloaded Software Package or coming

back to the previous condition.

A backup/restore can be also done on the MIB of the NE. Indeed the MIB can be saved to or restoredfrom the mass storage of the Craft Terminal.

The software download general principle is represented in the following figure.

MANAGER

SERVER

CLIENT

AGENT

NE

DownloadControl

EventReport

TransferRequest

Binary & DataFiles

Software Management

Software Downloading

OPERATOR

OPERATOR

Figure 335. Software Download general principle

Page 488: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

440

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

21.1.1 Naming Conventions

The naming conventions used for Download Management are the following:

– Software Package: Software Package stands for a piece of software which can be executed by anNE of a particular type. It consists in one or more Software Units and a Descriptor File. A softwarepackage is identified by its name, release, version and edition.On the NE (i.e. once downloaded) a software package can be:

– the active version: the software package currently running on the NE– a standby version: a software package which is neither the active version nor the boot

version

– Software Unit: A Software Unit is a part of a software package which can be either executable codeor a data segment of a particular board within an NE. A software unit is also identified by its name,release, version and edition.

– Descriptor File: A Descriptor File contains information about the software package it belongs to andlists the composing software units. Each software package must have a descriptor file otherwise itwould not be possible to interpret the content of the package.

– Software Management Function: The Software management function offers information about allcurrent software packages present in an NE. Indicators enable software management (runningpackage, activated package, etc...).

The following software version states are available:• Commit (active) version: the software version currently running on the NE.• Standby version: is a software version which has been downloaded on the NE but which is

not in the active state.

Two main functions are involved in the software downloading:– Software Download Manager function– Software Download Server function

The Software Download Manager function takes the downloading and management requests of theoperator and sends them to the NE. Thus, this function enables a download process to be initiated andmonitored by the operator. It manages the NE software releases and initiates software downloadoperations.

The Software Download Server is only responsible for fulfilling the requests received from NEs andperforming software package file transfer operations to the NE.

Page 489: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

441

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

21.2 Software download operative sequence

Two main different operative condition are defined for this Equipment:

• First installation of an OMSNThe NE is received without the relevant software install. The software download must be doneas described in the SIBDL section of this Handbook.

• Updating an OMSN with an already installed software.Follow the operative indications of para. 21.2.1 on page 441 .

21.2.1 Software Download upgrade

N.B. In order to migrate from Release 1.1A to a Higher Release, the download procedure requirestwo steps. The first is from 1.1A to 1.1X (intermediate package) and the second is from 1.1Xto the Higher Release (e.g. 1.1B1).

In order to update the following procedure is to be done as explained in the next steps:

a ) Install on the PC the NE Software Package present in the CD–ROM (refer to 1320CT BasicOperator’s Handbook for details).

b ) open a session on Craft Terminal application (start–up of the application, start supervision and NElogin)

c ) Check the present status of the software on a selected NE.

Download should not be performed in presence of unstable alarms

d ) Open the Download menu as for para. 21.3 on page 442.

e ) Select the new software package in the server and triggers the download process, as presented atpara.21.4 on page 443.A message will indicate the completed download.

f ) Activate the package as presented at para.21.5 on page 445.

g ) Check that the activated package is in the “Commit” status.

h ) If problems are found with the new activated package, activate the previous software package(revert–back operation) to come back to the previous condition and then try to repeat the procedure.

Page 490: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

442

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

21.3 Software Download Manager menu

All the software download operations are carried out from the software download manager.

Figure 336. Equipment view (example)

To display the software download manager menu from the main view, select the NE on which you want toperform download operations, then select the Download pull down menu. The following menu is displayed:

Figure 337. Download menu

Page 491: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

443

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

21.4 Init download

You can request the NE to start / abort a software download operation. After selecting the desired NE youmust choose an available software package and then start the download process. All these operationscan be performed from the SW downloading dialogue box.

Select the Init download option from the Download cascading menu.

The Software download initiate dialogue box is opened.

Figure 338. SW Downloading dialogue box example

The following fields are available to search a specific package:

– Server filter: to enter the server name selected,– Package filter: to enter the package name selected.

To use the filter and display the selection, push on Apply filter(s) button. The SW packages existing onthe Craft Terminal are displayed.

In the next field the list of the packages is displayed:

– Server: name of the server,– Package: name of the package,– Version: version number of package.

Click on Forced push button to set the forced download attribute: then all software units of the Descriptorfile have to be downloaded. Otherwise only the units with different software version will be loaded.

If you want stop the download, click on the Cancel push button of the Software download initiate dialoguebox to close it.

Page 492: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

444

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

Click on the OK push button to start the download. From the confirmation dialogue box that opens, youcan confirm or cancel the download. If you confirm the operation, the SW Downloading dialogue box thendisappears and the Software download in Progress dialogue box is displayed (see Figure 339. ) fromwhich you can if necessary abort the software download.You can monitor the download progress by means of the Software in Progress dialogue box which alsoenables you to possibly abort the current download.

Figure 339. Software download in progress (example)

The Software download in Progress dialogue box displays the name and type of the NE and the SWpackage name, the total of bytes, the current percentage and the current file which is being downloaded.Click on the Abort push button to abort the complete download transaction. From the confirmationdialogue box that opens you can confirm or cancel the abort.Click on the Close push button to close the SWDL Work in Progress dialogue box at the end of the softwaredownload.

Page 493: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

445

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

21.5 SW package Activation and Units information

This item permits to activate the downloaded software package and to get information about the softwareof the various units of the equipment.

The operator is able to get information about the software package of the NE at any moment, even if nodownload operations have been performed previously.

For this, select the Units info option from the Download pull down menu.

The following dialogue box is opened.

Figure 340. Software Package Information dialogue box (example)

The SW Information dialogue box displays the name and type of the NE, and the respective package nameand status of the committed and (if existing) the uncommitted software.

You can select one software package by clicking on the name.

Page 494: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

446

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

The following fields are displayed:

– Software package: name, release, version, edition of the package,– Service Specific Components: name, release, version, edition of the Service Specific Components

(example ATM, IP etc.)– Operational state: enabled or disabled,– Activation date: date and hour of the last activation– Vendor: the supplier of the product,– Current state\Action: commit or stand–by and with the option button; none/Force/Activate/Delete

current state = standby means the package is not active on the NEcurrent state = commit means the package is active on the NEaction = (none) means no action to doaction = activate serves to activate the selected SW packageaction = force

Select the Activate option of the “CurrentState\Action” field, to activate the Software package

The Sw units Det. button allows to give more information about a selected software package.

Clicking on it, the following window is displayed:

Figure 341. Detail software package (example)

Clicking on [–] symbol behind each software package all details disappear.

When you click on Close the previous view is displayed (Figure 340. ).

In Figure 340. when you click on the:

– OK push button you close dialogue box,– Cancel push button you close the SW Information dialogue box,– Help push button you access to help on context.

Page 495: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

447

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

21.6 Mib management

This function allows to make a backup and/or a restore of the Mib.. (MIB is a data base pertaining theconfiguration of the equipment).

Select the Mib management option from the Download pull down menu. The following window is displayed:

Figure 342. NE MIB management (example)

The following fields are displayed:

– Available backups on local server: gives the list of the backups available on the Craft Terminal,– Backup name: to enter the new backup name.

Three push buttons allow to choose the action with click on:

– Backup: performs the backup on the CT of the Mib present on the NE,– Restore: this function allows the managing system to restore the NE configuration database of the

managed system. Only one restore operation can be performed at the same time on a given NE.– Delete: this action allows to delete a backup of the NE database. The NE is not involved in this action.

The only effect is to delete the selected backup version stored in a specific directory of the FT server.

To activate an already restored MIB you click on Activate push button. Only at this point it becomesoperative on the NE.

To exit of the NE MIB management window, you click on Close push button.

To save or load the Mib to/from an external disk follow the indication of the “Basic 1320CT Operator’sHandbook” using the menu options of the Network Element Synthesis.

Page 496: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

448

02

SC.3:NE MANAGEMENT

/3AL 91670 AA AA

448

448

END OF DOCUMENT

Page 497: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

1

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

METRO OMSN REL. 4.4/5.2A OPERATOR’S HDBK

TABLE OF CONTENTS

LIST OF FIGURES AND TABLES 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 INTRODUCTION 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Scope 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.1 Document scope 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.2 Target audience 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2 Terminology 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.1 Acronyms and abbreviations 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.2 Glossary of terms 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 MAINTENANCE INTRODUCTION 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Maintenance of the PC 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Problems with Craft Terminal 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.2.1 Purpose of the procedure 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.2 Procedure 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 CORRECTIVE MAINTENANCE (TROUBLESHOOTING) 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Purpose of the procedure 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Troubleshooting organization 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 On site Troubleshooting 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4 Troubleshooting by means of the Craft Terminal. 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.4.1 Preliminary Concepts and Definitions 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.2 Alarms/states view Organization (subrack view) 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.3 Alarm synthesis indication 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.4 Alarm Surveillance (AS) 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.5 Port View alarms 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.6 Board view alarms and states 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.7 Subrack and Rack view alarms 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.8 AC/DC Rectifier alarms view 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.9 Equipment View alarms 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.10 External Points alarms (HouseKeepings) 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 UNIT REPLACEMENT WITH A SPARE 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 EQUICO or PQ2/EQC unit replacement 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 COMPACT ADM unit replacement 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3 ATM MATRIX 4X4, 4x4 V2, 4X4 D3 units replacement 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ED DATE CHANGE NOTE APPRAISAL AUTHORITY ORIGINATOR

01 041119 C. FAVERO ITAVE P.GHELFI ITAVE

02 050414 ECR 23082 C. FAVERO ITAVE P.GHELFI ITAVE

METRO OMSNRel. 4.4/5.2AOPERATOR’S HANDBOOK

J.MIR – S.MAGGIO

J.MIR – S.MAGGIO

Page 498: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

2

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

4.4 ATM MATRIX 8X8 unit replacement 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5 CONGI unit replacement 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5 UPGRADING WITH NEW HARDWARE 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 MATRIX substitution with MATRIXN 60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 SYNTH1 substitution with SYNTH1N 61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.2.1 Procedure for 1650SMC 61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.2 Procedure for 1640FOX 65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.3 P4S1, S–41, L–41, L–42, S–161, L–161, L–162 substitution with P4S1N, S–41N, L–41N,L–42N , S–161N, L–161N, L–162N 67. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4 P21E1 substitution with P21E1N (only for 1640FOX) 67. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6 FLASH CARD SUBSTITUTION 69. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1 Flash card substitution procedure for 1660SM 69. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2 Flash card substitution procedure for 1650SMC 71. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3 Flash card substitution procedure for 1640FOX 74. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 499: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

3

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

LIST OF FIGURES AND TABLES

FIGURESFigure 1. General Flow–chart for on site troubleshooting 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2. Flow–Chart for 1660SM/1650SMC Power Supply alarm 15. . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3. Flow–Chart for 1640FOX Power Supply alarm 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4. Transmission network level structure 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 5. Alarms/status view Organization (subrack view example) 19. . . . . . . . . . . . . . . . . . . . . . . . . . Figure 6. Alarm pull down menu. 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 7. Alarm Surveillance 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 8. Example of SDH Port View alarms (without MSP schema) 31. . . . . . . . . . . . . . . . . . . . . . . . . Figure 9. Example of SDH Port View alarms (with MSP schema) 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 10. Example of ATM Port View alarms 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 11. Example of 10/100 Mbit/s Ethernet Port View alarms 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 12. Gigabit/s Ethernet Port View alarms 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 13. Example of board view alarms and status 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 14. Example of “daughter” View alarms and status 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 15. Example of PDH Board View alarms and status 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 16. 1660SM Subrack view alarms and status example 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 17. 1660SM Rack view alarm and status example 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 18. 1660SM Fans subrack alarms view example 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 19. AC/DC Rectifier View alarms and status 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 20. Example of Equipment View alarms and status 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 21. Example of 1650SMC Equipment View alarms and status 45. . . . . . . . . . . . . . . . . . . . . . . . . Figure 22. Example of 1640FOX equipment View alarms and status 46. . . . . . . . . . . . . . . . . . . . . . . . . Figure 23. Example of External Points alarms and status 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 24. EQUICO or PQ2/EQC unit replacement 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 25. COMPACT ADM unit replacement (EPS protected) part “A” 53. . . . . . . . . . . . . . . . . . . . . . . Figure 26. COMPACT ADM unit replacement (EPS protected) part “B” 54. . . . . . . . . . . . . . . . . . . . . . . Figure 27. COMPACT ADM unit replacement (EPS not protected) 55. . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 28. ATM MATRIX 4X4 and 4x4 V2 units replacement without EPS protection 56. . . . . . . . . . . Figure 29. ATM MATRIX 4X4 unit replacement with EPS protection 57. . . . . . . . . . . . . . . . . . . . . . . . . . Figure 30. 1650SMC: Upgrading with a new SYNTH1N EPS not protected 62. . . . . . . . . . . . . . . . . . . Figure 31. 1650SMC: Upgrading with a new SYNTH1N EPS protected 64. . . . . . . . . . . . . . . . . . . . . . . Figure 32. 1640FOX: Upgrading with a new SYNTH1N 66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 33. FLASH CARD substitution 70. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 34. FLASH CARD substitution (COMPACT ADM EPS protected) 72. . . . . . . . . . . . . . . . . . . . Figure 35. FLASH CARD substitution (COMPACT ADM EPS not protected) 73. . . . . . . . . . . . . . . . . Figure 36. FLASH CARD substitution (on COMPACT ADM unit) 75. . . . . . . . . . . . . . . . . . . . . . . . . . . .

TABLESTable 1. Alarms colors and Severity association 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 2. Alarm Synthesis indication 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3. Domain Alarm Synthesis indication 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4. Management States Control Panel. 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5. Alarm Surveillance information general description 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6. General aspect of alarms meaning and relevant maintenance actions 24. . . . . . . . . . . . . . . . Table 7. Boards alarms 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 8. Module alarm 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 500: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

4

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Page 501: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

5

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

1 INTRODUCTION

1.1 Scope

1.1.1 Document scope

The Maintenance Manual mainly describes the NE troubleshooting with Craft Terminal.

1.1.2 Target audience

The Maintenance Manual is intended for all users.

The documents that should be read before starting this document are:

– 1320CT Basic Operator’s Handbook

The documents of this Handbook that should be read before starting this document are:

– Introduction manual

– NE Management manual

1.2 Terminology

1.2.1 Acronyms and abbreviations

Refer to the Section Introduction manual.

1.2.2 Glossary of terms

Refer to the Section Introduction manual.

Page 502: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

6

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Page 503: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

7

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

2 MAINTENANCE INTRODUCTION

The maintenance procedures consist of the following steps:

– Maintenance of the PC.See Chapter 2.1 on page 8

– Problems with Craft terminal (shut–down and restart of the PC).See Chapter 2.2 on page 8.

– Corrective Maintenance (Troubleshooting).See Chapter 3 on page 9.

– Unit replacement with a spare.See Chapter 4 on page 49.

– Upgrading with new Hardware.See Chapter 5 on page 59 .

– Flash Card substitution.See Chapter 6 on page 69 .

Page 504: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

8

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

2.1 Maintenance of the PC

With regard to maintenance PC, refer to the constructor’s documentation.

2.2 Problems with Craft Terminal

2.2.1 Purpose of the procedure

This procedure describes the Shut–down and restart the PC should the Craft Terminal SoftWare Productnot be working properly or not responding to the operator’s commands.

2.2.2 Procedure

In order to shut down the PC execute the command :

Start > Shut down

A window (Windows NT Security user dialog) is displayed. It permits to shut down the computer or restartit.

The same window is displayed pressing he keys <Ctrl> + <Alt> + <Del> simultaneously.

Page 505: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

9

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3 CORRECTIVE MAINTENANCE (TROUBLESHOOTING)

3.1 Purpose of the procedure

Troubleshooting involves the detection, location and correction of failures in the equipment and thereplacement of the defective parts.

3.2 Troubleshooting organization

The troubleshooting procedure is carried out with the help of some flow–charts and tables, reportedhereinafter. Anyway this method does not deal with the following aspects (which are to be deduced in otherways):

– faulty electronic alarm indication, processing and detection circuits– faulty wiring (back–panel, connectors, etc.)

The following interfaces are present to troubleshoot the equipment :

• Q3 interface for Telecommunication Management Network

• Q–ECC interface for Telecommunication Management Network (via DCC channels, linked tothe relevant OS)

• F interface for Craft Terminal (Local or Remote)

• Remote Alarm for Supervisory Center

• LEDs on the units of the NE

Usually maintenance is firstly done via software (TMN or Remote Craft Terminal) to locate the faultyequipment and the faulty unit or the faulty path and then on site to physically solve the trouble.

The Maintenance can be done :

[1] from a TMN network management center

[2] from a Remote Craft Terminal (RCT) management center

[3] from a station supervisory center

[4] on site

[1] TMN network management center: by means of the TMN the maintenance technician can see thealarms sent by each equipment of the managed network (see the relevant TMN handbooks).

[2] Remote craft terminal: the operator, connected to a local NE , can remotely manage andtroubleshooting a network composed of max 32 NEs included itself. This handbook is used.

Page 506: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

10

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

[3] Station supervisory center: the maintenance technician refers to the Remote Alarms received fromthe equipment in a centralized office of the station i.e. :

• 1660SM and 1650SMC

– T URGENT (MAJOR and CRITICAL), T NOT URGENT (MINOR): remote alarms pertaining tothe urgent, not urgent alarm type.

– TOR, TAND: remote alarms respectively due to the decrease or loss of one or both stationpower supply DC voltages.

– INT: Remote alarm pertaining to the local (internal) alarm type

When a second CONGI unit is used the following remote alarms are added:

– TORC, TANC: remote alarms respectively due to the loss of +3,3V generated by the on boardconverter in of one or both the CONGI units.

– IND: Indeterminate alarm synthesis. Indicates synthesis of alarms not associated to othersseverities. Not operative.

– TUP: remote alarm due to microprocessor fault in the EQUICO unit (for 1660SM), PQ2/EQCunit (for 1660SM Rel. 5.1) or SYNTH1N/SYNTH4 unit (for 1640FOX,1650SMC)

– LOSQ2: remote alarm due to loss of communication with Mediation Device. Not operative.

• 1640FOX

– T URGENT (MAJOR and CRITICAL), T NOT URGENT (MINOR): remote alarms pertaining tothe urgent, not urgent alarm type.

– INT (MAJOR or CRITICAL): Remote alarm pertaining to the local (internal) alarm type– INTALM (WARNING): Remote alarm due to alarm detection from the external Converter

SR40R.– TAND (MAJOR or CRITICAL): remote alarm due to the loss of power supply (battery–fail or

–3.3VService fail).– FANSOFF1 (WARNING): remote alarm due to failure of FOX fans.– FANSOFF2 (WARNING): remote alarm due to failure of external Converter (SR40R) fans.

Depending on the supervisory center organization, it is possible to locate the equipment in troubles andto detect the failure type and source.

[4] On site : the operator is on site in case :

1 ) the equipment is not managed by a TMN or by a Remote Craft terminal (RCT)

2 ) the equipment is not reachable by the remote manager (TMN or RCT) and is therefore isolated

3 ) link problems are present

4 ) the trouble has been located and a substitution is necessary

In case 1 ) , 2 ), 3 ), the alarmed equipment is checked by means of the local Craft Terminal and of rackLED indications and station buzzers.

The NE is provided with LEDs which indicate:

Page 507: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

11

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Units Alarms:

Each port card or access card of the equipment is provided with a bicolor LED (green/red) or multicolorLED (green/red/yellow) at the bottom of the front coverplate.

Bicolor LED indicates:– when red, internal failure (indicates that the unit concerned must be replaced)– when green, in service unit

Multicolor LED indicates:– when red, internal failure (indicates that the unit concerned must be replaced)– when green, in service unit– when yellow, means that the unit is part of an EPS schema and its status is “standby” (only available

on 1650SMC and 1660SM)

AC/DC Rectifier Alarms: (only for 1640FOX)

The AC/DC is provided with four LEDs on the front coverplate, which indicate (from top to bottom):

• Red LED: detection of an INTERNAL alarm (rectifier failure or rectifier fans failure)• Yellow LED: battery charging• Red LED: AC mains off (missing of AC power)• Green LED: rectifier is operating

ATM unit Alarms:

All the alarm detected on the unit are related to the ATM traffic management; on the front coverplate arepresent optical indication (LEDs) with the following meaning (from the top to the bottom):

• Red LED : detection of an MAJOR or CRITICAL (URGENT) alarm

• Red LED : detection of a MINOR (NOT URGENT) alarm

• Yellow LED : alarm condition ATTENDED

• Yellow LED : detection of an ABNORMAL operative condition.

• Yellow LED : detection of an WARNING (INDICATIVE) alarm

Page 508: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

12

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Centralized Equipment Alarms:

All the alarms detected on the units are collected by the “Controller” unit (called EQUICO in 1660SM,SYNHT1N or SYNTH4 in 1640FOX/1650SMC) unit which will deliver centralized optical indications (bymeans of LEDs on its front coverplate). Specifically, from the top to the bottom :

• Red LED: detection of an URGENT (MAJOR and CRITICAL) alarm

• Red LED: detection of a NOT URGENT (MINOR) alarm

• Yellow LED: alarm condition ATTENDED

• Yellow LED: detection of an ABNORMAL operative condition. Type: active loopbacks, forcingthe unit into service, laser forced ON or OFF, try to restore after ALS

• Yellow LED: detection of an INDICATION (WARNING) alarm

The analysis of these LEDs permits to detect the alarm type (Urgent – Not Urgent – Indication) andrelevant condition (Abnormal condition, Attended).In case of URGENT or NOT URGENT alarm, after having located the alarmed equipment, the alarmcondition can be ”attended” by pressing the relevant alarm storing push button on the EQUICO, PQ2/EQC,SYNTH1N, SYNTH4 unit.

This condition causes:

– On the rack

• the YELLOW LED to light up• the RED LED to go off

– On the front coverplate:

• yellow LED (ATTENDED) to light up• red LEDs NOT URGENT (MINOR) and URGENT (MAJOR and CRITICAL) to turn off (free to

accept other alarms)If both LEDs are on, the Attend command should be given twice : one for attending the NOTURGENT (MINOR) alarm and one for attending the URGENT (MAJOR) alarm.

Page 509: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

13

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.3 On site Troubleshooting

The trouble–shooting operation proceeds according to the information indicated in the flow–charts:

– Figure 1. on page 14: General flow–chart

– Figure 2. on page 15: Flow–Chart for 1660SM/1650SMC Power Supply alarm

– Figure 3. on page 16: Flow–Chart for 1640FOX Power Supply alarm

and according to para.3.4 on page 17.

As indicated in the flow–charts the troubleshooting operation is done by means of the Craft Terminal, andof the optical indicators (LEDs) present on the NE.

The Craft Terminal is cord–connected to the relative connector on the “Controller” unit(EQUICO,PQ2/EQC,SYNTH1N,SYNTH4) front coverplate (F interface).

The Craft Terminal applications provide detailed information on the alarm state thus facilitating faultlocation and subsequent removal as indicated in para. 3.4 on page 17.

To correctly execute the troubleshooting operations the technician must know the exactequipment configuration (see Equipment Configuration applications on the Craft Terminal).

The aim of the flow–charts which follow and of the maintenance tables is to locate the faulty unit and toreplace it with a spare as well as to locate a failure along the link.

The flow–charts/tables should be also consulted when the unit LEDs flash, because the flashing conditionmight be due to external alarm causes usually related to line problems.

Page 510: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

14

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

START

AN ALARMIS PRESENT

IN CASE OF URGENT OR NOT URGENT ALARM

IS THE

CONTROLLER (*)

BICOLOR LED RED?

NO

IS THE

RED LED URGENT (MAJOR)

NO

ON ?

THROUGH PUSH–BUTTON

RESET THE UNIT

DOESTHE ALARM

CONDITIONPERSIST ?

NO TRANSITORY

FAILURE

THE UNIT IS FAULTY. REPLACE IT ACCORDINGTO THE DESCRIBED PROCEDURE

IS

ONE OF THE BICOLORLEDS INDICATING UNIT

FAILURE RED?

NO

YES

REPLACE THE UNIT IN ALARM.BY CONNECTING THE PC AND

ACCORDING THE TYPE OF FAILURE

THE FAULTY UNIT CAN BEREPLACED (OR NOT) IN CASE

OF LOW TRAFFIC .

END

CONNECT THE PC TO THEEQUIPMENT AND, ACCORDING TOTHE TYPE OF DETECTED ALARM,

PROCEED AS STATED IN

END

IS THE

NOT URGENT (MINOR) YELLOW

LED ON ?

NO

YES

CONNECT THE PC TO THE EQUIPMENT,

END

AFTER HAVING DETECTED THE TYPEOF FAILURE, ESTABLISH IF

INTERVENTION MUST BE IMMEDIATE ORNOT AS STATED IN THE RELATIVE

YELLOW ALARM IS ON. MAINTENANCE OPERATION

MUST BE PERFORMEDON THE EQUIPMENT CONNECTED

TO THE LOCAL ONE. CONNECT THE PC AND ACCORDING TO

THE TYPE OF ALARM PROCEEDAS INDICATED IN

YES

YES

YES

YES

YES(see chapter 4 on page 49)

PARA 3.4 ON PAGE 17

ATTEND IT WITH THE BUTTON

CONTROLLER(*) UNIT

AND THE TRAFFIC DAMAGE

CONTROLLER (*) UNIT

IN CONTROLLER (*) UNIT

THE INDICATION (WARNING)

PARA 3.4 ON PA GE 17

PARA 3.4 ON PA GE 17

NOTE:

(*) CONTROLLER UNIT IS:

SYNTH1N or SYNTH4 for 1640FOX,1650SMCEQUICO PQ2/EQC for 1660SM

ON THE CONTROLLER UNIT(*)

––_

Figure 1. General Flow–chart for on site troubleshooting

Page 511: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

15

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

START

ISREMOTE ALARM

TAND PRESENT ?

(N.B.)

NO

STATION POWER

SUPPLY FAILURE

END

OVERLOAD LIKELY TO HAVEBEEN CAUSED BY ONE OF THE

ASSEMBLY UNITS.

REMOVE ALL THE UNITS

INSERT THEM BACK ONEAT A TIME TILL THE ONE

CAUSING THE FAILURE IS DETECTED.HENCE REPLACE IT.

END

ALL LED’S OFF

N.B. IF THE REMOTE ALARMS ARE NOT UTILIZED CHECK FOR PRESENCE OF STATION POWER SUPPLY.

SHOULD IT HAVE FAILED THEN ALL THE UNIT’S LEDS WILL BE OFF (FOLLOW OUTPUT “YES” OF THEFLOW–CHART).

IF POWER SUPPLY IS PRESENT PROCEDE WITH OUTPUT “NO”.

NO

YES

YES

SUBSTITUTE THE FUSE ON THE CONGI UNIT

ARE LEDS ACTIVE?YES

TRANSITORY OVERLOAD

FROM THE SUBRACKAND SUBSTITUTE THE FUSE

IF NECESSARY.

SUBSTITUTE THE FUSE IF NECESSARY.

WARNING!

Before removing CONGI unit from subrack, switch–off the relevant Station Battery Fuse Breakerpresent at the top of the Rack or in the Station Distribution Frame; subsequently remove the station battery cable if necessary and then extract the CONGI unit.

Figure 2. Flow–Chart for 1660SM/1650SMC Power Supply alarm

Page 512: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

16

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

START

ISREMOTE ALARM

TAND PRESENT ?

(N.B.)

NO

STATION POWER

SUPPLY FAILURE.

END

OVERLOAD LIKELY TO HAVEBEEN CAUSED BY ONE OF THE

ASSEMBLY UNITS.

ALL LEDS ARE OFF

N.B. IF THE REMOTE ALARMS ARE NOT UTILIZED, CHECK FOR PROBLEMS ON STATION POWER SUPPLY (OR ONAC/DC RECTIFIER)

SHOULD IT HAVE FAILED, THEN ALL THE UNITS LEDS WILL BE OFF (FOLLOW OUTPUT “YES” OF THEFLOW–CHART).

IF POWER SUPPLY IS PRESENT PROCEDE WITH OUTPUT “NO”.

YES

REMOVE ALL THE UNITS

INSERT THEM BACK ONEAT A TIME TILL THE ONE

CAUSING THE FAILURE IS DETECTED,HENCE REPLACE IT.

FROM THE SUBRACK,

SUBSTITUTE THE SHELF,IF THE ALARM PERSISTS.

END

OR AC/DC RECTIFIER

FAILURE

Figure 3. Flow–Chart for 1640FOX Power Supply alarm

Page 513: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

17

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4 Troubleshooting by means of the Craft Terminal.

The troubleshoot proceeds checking the detailed information on the NE alarm by means of the craftterminal.

The information on the NE alarm will be mainly obtained by means of the craft terminal through the AlarmSurveillance data and the alarms/status indications presented in the various views, depending on thelevel of the structure under observation.Navigation across the various level views is done from higher to lower levels, by double clicking on theobjects (see instructions on “NE management” section).The NE hierarchy is organized in the following order: NE > rack > subrack > board > port > TP.

The troubleshoot procedure with the the Craft Terminal consists of the following steps:

a ) An example of alarms/status view organization is shown in Figure 5. pg. 19. Observe the activealarms on the Severity Alarm Synthesis, Domain Alarm Synthesis and Management StatesControl Panel always present on the window (it resumes all the NE alarms).Table 2. on page 20 describes the meaning of these alarms/statuses and the relevant maintenanceactions.

b ) in case of alarm presence, access the Alarm Surveillance to troubleshoot. This application givesthe details of the detected alarms and helps for their localization.Para 3.4.4 on page 22 describes this view.

c ) It is possible to analyze the detailed alarm presence on the TPs of each ports of the NE, followingthe indication of para 3.4.5 on page 30.

d ) It is also possible to check alarm and status at Board view, Subrack view and Equipment vieware also supplied following the indication of para 3.4.6 on page 37 and para 3.4.9 on page 44.

e ) Eventual housekeeping alarms can be localized following the indications given in para. 3.4.10 onpage 47.

f ) These above said paragraphs describe general aspect of alarms meaning and relevant maintenanceactions that can be done with the information given in the applications.

g ) The history of past events can be obtained by means of the Event log option of the Diagnosis pulldown menu (see “NE management” section).

In case of unit replacement, follow the indications reported in Chapter. 4 on page 49.

Troubleshooting with Automatic Laser Shutdown

The Automatic Laser Shutdown (ALS) is used to protect the operator who is working with the optical fiber.When the ALS is active, it may be difficult to detect the link failed.To locate it, it is necessary to ”force on” the ALS, thus enabling the optical power transmission on theopposite direction of the failed link.WARNING: During this phase the operator has to pay attention when working with fibers and connectors.The ABNORMAL indication inform the operator of the ALS forced condition.After having completed the maintenance, enable the ALS.The ALS states are indicated in the port view, as described in para. 3.4.5 on pg. 30.

Page 514: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

18

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.1 Preliminary Concepts and Definitions

The following concepts and definitions are considered useful to facilitate maintenance operations with theaid of the previously indicated tables.

The various units specified in the synchronous multiplexing hierarchy imply structuring the Transmissionnetwork into three levels (sublevels of the physical OSI level):

– Transmission bearer level. It is the support for the path level and can be further split into physicallevel (Transmission media) and Transmission section level. The sections can be either regeneratoror multiplexer and utilized for specific functions associated to the EOW channels of the SDH frame.The interface alarms (or section alarms, indicated in the tables) belong to this level (example: LineLOS, LOS, B2etc.).

– Path level It concerns the data transfer between the access points and the path. It does not dependon the service nor on the type of Transmission media. It constitutes the circuit level support. The pathcan be either lower order (LO) or higher order (HO) depending on the capacity of data transferring.Like the regenerator and multiplexer sections, the paths too have specific functions associated to theEOW channels of the SDH frame. The alarms listed in the cited tables, where path leveltroubleshooting is required, belong to this level (example:TUAIS, TU LOP).

– Circuit level. This level concerns the transfer of information between the access points and thecircuit proper. It is a direct support for the telecommunication services. It superimposes the SDH function and is considered as the transport agent hence no SDH order–wire channel associatedfunctions are required. An example of this level alarm is Tributary LOS.

The above level structuring in the Transmission network is depicted in Figure 4.

TRIBUTARIES SDH MUX

G.703

STM–NREGENERATOR

SDHMUX

STM–N

TRIBUTARIESSDH MUX

G.703

STM–N

RSOHREGENERATOR

SECTION

RSOHREGENERATOR

SECTION

MSOHMULTIPLEXER

SECTION

MSOHMULTIPLEXER

SECTION

POH PATH

MSOHMULTIPLEXER

SECTION

Figure 4. Transmission network level structure

Page 515: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

19

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.2 Alarms/states view Organization (subrack view)

Severity alarmssynthesis

Message/status area

View area

View title

Domain alarms synthesis

Management status control panel

Menu bar

Administrativestate indications

Boards

Alarms

LCA

Figure 5. Alarms/status view Organization (subrack view example)

the critical (CRI) or major (MAJ) alarms indicate severe alarms that could have impact on thecurrent traffic (interruption or degrade). Thus requiring a rapid intervention to restore theregular working condition of the equipment.

A message under the mouse facility provides the alarm or status complete denomination. A messageappears in the message area in the bottom left corner of the view.

Page 516: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

20

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.3 Alarm synthesis indication

Alarms and Statuses synthesis are given in all the screens.

The alarms CRI, MAJ, MIN, WNG, IND are part of the Severity Alarms Synthesis area, presented inTable 2. on page 20.

The alarms EXTP, EQP, TRNS are part of the Domain Alarms Synthesis area, presented inTable 3. onpage 21.

The alarms SUP, ALI, LAC, COM, OS, MGR, NTP and AC are part of the Management States ControlPanel, presented in Table 4. on page 21.

All these indications (except for SUP, ALI, LAC, COM, OS, MGR and NTP) are the summaries of particulartypes of alarms detected by the equipment, hence the specific cause of alarm is to be found as indicatedin the following paragraphs: 3.4.4, 3.4.5, 3.4.6, 3.4.7, 3.4.10.

Table 1. reports the association between the colors of the Alarms and their Severity.

For the Domain Alarms Synthesis the color corresponds to the highest severity among the set of theactive alarms for the relevant domain, according to the same rules of previous Table 1.

Table 1. Alarms colors and Severity association

Alarm Color Severity

RED CRITICAL

ORANGE MAJOR

YELLOW MINOR

CYAN WARNING

WHITE INDETERMINATE

GREEN NO ALARM

Table 2. Alarm Synthesis indication

Mnemonic Alarm/Status Description Maintenance

CRI Critical alarmSynthesis of alarms that needs immediate trouble-shooting (typical: NE isolation). NB1.See detailed indication in the following para.

MAJ Major (Urgent) alarmSynthesis of alarms that needs immediate trouble-shooting. NB1. See detailed indication in the follow-MAJ Major (Urgent) alarm shooting. NB1. See detailed indication in the follow-ing para.

MIN Minor (Not urgent) alarmSynthesis of alarms for which a delayed troubleshoot-ing can be defined. NB1.See detailed indication in the following para.

WNG Warning alarmSynthesis of alarms due to failure of other NE in thenetwork. NB1.See detailed indication in the following para.

IND Indeterminate alarmSynthesis of alarms not associated to the previousseverities. Not operative.See detailed indication in the following para.

Page 517: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

21

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Table 3. Domain Alarm Synthesis indication

Mnemonic Alarm/Status Description Maintenance

EXTPExternal Point

(Housekeeping alarm)

Check the relevant station alarm associated to theinput housekeeping indication. See detailed indicationin the following para.

SYNC Synchronization alarmSynthesis of alarms of the Synchronization domain.

See unit detailed indication in the following para.

EQP Equipment alarmSynthesis of alarms of the Equipment domain.

See unit detailed indication in the following para.

TRNS Transmission alarmSynthesis of alarms of the Transmission domain.

See unit detailed indication in the following para.

Table 4. Management States Control Panel.

Mnemonic Description Maintenance

SUP Supervision state

GREEN: NE is under supervision.

BROWN: NE is not under supervision.

Used in the OS.

ALIAlignment state

(not operative on Craft

Terminal)

GREEN: configuration is aligned (is equal betweenEML manager and NE MIB).

ORANGE: configuration is not aligned (is not equalbetween EML manager and NE MIB).

LCA Local Control Access

GREEN: Indicates that the Craft Terminal has the OSpermission to manage the NE (Granted).

CYAN: Indicates that the Craft Terminal has not theOS permission to manage the NE (Denied).

BLUE: Indicates that the Craft Terminal has re-quested OS permission to manage the NE (Re-quested).

COM NE unreachable/unreachable

GREEN: Identifies the “Enable” operational state ofthe connection between NE and Craft Terminal (SDHservice link up)

RED: Identifies the “Disable” operational state of theconnection between NE and Craft Terminal (SDH

service link down)

OS Operational System Isolation

GREEN: Indicates that the N.E. is not managed by the1353SHCYAN: Indicates that the N.E. is managed by the1353SH.

MGR Manager level

GREEN: Indicates that the N.E. is not managed bythe 1354RM

CYAN: Indicates that the N.E. is not managed by the1354RM

NTP Network Time Protocol

GREEN: NTP protocol enabled and both NTP servers(main and spare) are unreachable.

BROWN: NTP protocol disabled.

CYAN: NTP protocol enabled and at least one NTPservers (main or spare) are reachable.

AC Abnormal Condition

GREEN: normal operating condition.

CYAN: detection of an ABNORMAL operative condi-tion. Type: active loopbacks, forcing the unit into ser-vice, laser forced ON or OFF, try to restore after ALS

Page 518: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

22

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

NB1: Alarm Severity Assignment Profile can modify the assignment of each alarm root to the varioussynthesis.

3.4.4 Alarm Surveillance (AS)

– In case of alarm presence, access the Alarm Surveillance (AS) to troubleshoot. For this purposeselect the Diagnosis pull down menu. With the Alarm pull down menu (see Figure 6. ). It is possibleto show all the NE Alarms or filter the alarms report, for example displaying only the alarms of aspecific domain (i.e. only alarms of the Equipment domain).

Figure 6. Alarm pull down menu.

After the selection a list with a synthesis of the Alarm Surveillance is presented and immediately after alsothe detailed list of the Alarm Surveillance (see Figure 7. ).In the synthesis list it is possible to filter the data to show with the detailed view, double clicking on theselected row of the sublist of Figure 7.

LCA

Figure 7. Alarm Surveillance

Page 519: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

23

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Detailed information of each alarm are supplied.The alarms scenario is indicated by the colors of the alarms and by the information displayed in the table.For instance, if an alarm is still active, the whole row has the same color of its relevant “Perceived Severity”;else if it has been cleared, the color of the row is green (except the “Perceived Severity”). The sameinformation is reported in the “Clearing Status” column.

In the following are shortly described the main information obtained in the AS view, starting from the leftcolumn:

Table 5. Alarm Surveillance information general description

TITLE DESCRIPTION

– Perceived SeverityThe severity assigned to the alarm is indicated, with the relevant color,i.e.: MAJOR, MINOR, WARNING....

– Event date and time Indicates year, month, day and hour of the alarm.

– Friendly NameIdentify the rack, subrack, board, port, and TP in which the alarm is detected,i.e.: / r01sr1sl09/#port01–E1S

– Event TypeIndicates the family type of the alarm as subdivided in the ASAP list, i.e.:EQUIPMENT, COMMUNICATION,

– Probable CauseThe fault/problem is indicated, i.e.: loss of signal, transmitter degraded, re-placeable unit missing,resource isolation, ...

– Reservation StatusIndicates if the alarm is reserved (RSV) or not (NRSV) according securitymanagement.

– Clearing statusIndicates if the alarm condition is terminated (CLR) or is still active (NCLR).If cleared it has a green background,

– Acknowledge statusIndicates if the alarm has been acknowledge (ACK) with the button on theController unit ( EQUICO/ PQ2/EQC / SYNTH1N / SYNTH4) or not ( NACK).

– Correlated notification flag

Not used

– Repetition counter Not used

The information supplied help the operator during the troubleshooting operation.

Table 6. on page 24 supply general indications of alarms meaning and relevant maintenance actions thatcan be done with the information given in the applications.The maintenance action must take into account the board where the alarm is detected.

External Points alarms are referred to the input external point relevant to the Housekeeping signals. Theyare available for the customer by connecting them to a dedicated subrack connector.

Detailed description of this application is given in the AS Operator’s Handbook.

Page 520: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

24

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Table 6. General aspect of alarms meaning and relevant maintenance actions

PROBABLE CAUSE

NAME AND/OR ACRONYMOF DISPLAYED ALARM

MAINTENANCE

Loss of signal (LOS) Check line

Transmitter Signal (TF) Replace unit

Transmitter degraded (TD) Replace unit when possible (laser degrade)

Loss of frame (LOF) Check line (alignment problems due to line error)

AIS Check connected equipment

Excessive BER (EBER) Check line (excessive line BER)

Degraded Signal (DS) Check line (line signal degrade)

Loss of Pointer (LOP) Check line

Payload Mismatch (PLM) Configuration error

Far End Received Failure(FERF)

Check far–end equipment

Server Signal Failure (SSF) Check all the TU path. Alarm indicates AIS signal received onthe TU

Frequency offset (DRIFT) Check reference and connection between it and the equipment

Loss of timing source (LOSS) Check reference and connection between it and the equipment

Resource Isolation Check connection between NE and Craft Terminal

Communication SubsystemIsolation (CSF)

Check Communication configuration (LAPD)

Unequipped (U)

Referred to Signal LabelConfiguration error

Unconfigured EquipmentPresent (UEP)

Unit inserted but not declared

Internal Communication Prob-lem

Reset NE. If persists substitute EQUICO / PQ2/EQC SYNTH1N /SYNTH4 unit according to the NE type.

URU – Underlying ResourceUnavailable

Insert the board

PM_AS– PerformanceMonitoring Alarm Synthesis

Check path / line section interested to the indication.

CPE–Communication protocolerror

Check MSP protocol (architecture type, switch fail)

LOMF – Loss Of MultiFrame Check payload structure

Page 521: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

25

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

MAINTENANCEPROBABLE CAUSE

NAME AND/OR ACRONYMOF DISPLAYED ALARM

AUXP Check far–end equipment

Remote Node Transmissionerror (RNTE)

Check far–end equipment

Table 7. Boards alarms

NAME AND

ACRONYM

OF DISPLAYEDALARM

BOARDACRONYM

MAINTENANCE

Unit missing

(RUM)

A2S1A21E1A3E3A3T3

A4ES1AFOX

ETH–ATXETH–MB

GETH–AGHPROT

L–41L–41N

Insert missing unit

Unit Problem

(RUP)

L–41NL–42

L–42NM4E1M1E3M1T3

P3E3/T3P4ES1N

P4S1P4S1NP21E1

P21E1NP21E1N–M4

P63E1

Replace unit

Unit type mismatch

(RUTM)

P21E1N–M4P63E1

P63E1NP63E1N–M4

S–41S–41N

ES1–8FEES4–8FESERVICECOADM1COADM2COWLA2COMDX8

Insert right unit (unit inserted into a slot set with another type ofunit)

Page 522: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

26

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

MAINTENANCEBOARDACRONYM

NAME AND

ACRONYM

OF DISPLAYEDALARM

Unit Problem

(RUP)EQUICOPQ2/EQC

Replace unit

Unit missing(RUM) Insert missing unit

Unit Problem

(RUP)Replace unit

Unit type mismatch

(RUTM) PR16

Insert right unit (unit inserted into a slot set with another type ofunit)

Power Problem(POP)

PR16

Replace unit

Pump failure(PF)

Replace unit

Enclosure Door Open(EDO)

Check that the protection cover in front of the unit has been cor-rectly placed.

Unit missing(RUM) Insert missing unit

Unit Problem

(RUP)BST10

Replace unit

Unit type mismatch

(RUTM)

BST10BST15BST17

Insert right unit (unit inserted into a slot set with another type ofunit)

Pump failure(PF)

Replace unit

Enclosure Door Open(EDO)

Check that the protection cover in front of the unit has been cor-rectly placed.

Page 523: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

27

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

MAINTENANCEBOARDACRONYM

NAME AND

ACRONYM

OF DISPLAYEDALARM

Unit missing(RUM) Insert missing unit

Unit Problem(RUP)

GETH–MBES1–8FE

Replace unit

Unit type mismatch(RUTM)

ES1–8FEES1–8FXES4–8FE

ES16

Insert right unit (unit inserted into a slot set with another type ofunit)

Internalcommunicationproblem(ICP)

ES16

Internal dialogue problem in the unit. It indicates a temporary con-dition which will be restored. If the condition persists it is due to aunit hardware failure: in this case it will activate the RUP alarm

Unit missing(RUM)

MATRIX

Insert missing unit

Unit Problem(RUP)

MATRIXMATRIXNMATRIXE

Replace unit

Unit type mismatch(RUTM)

MATRIXEPREA1GBEPREA4ETH

ATM8X8

Insert right unit (unit inserted into a slot set with another type ofunit)

Version Mismatch

ATM8X8ATM4X4SYNTH1

Update software version by means of SW download

Internalcommunicationproblem(ICP)

SYNTH1SYNTH1NSYNTH4 Internal dialogue problem in the unit. It indicates a temporary con-

dition which will be restored. If the condition persists it is due to aunit hardware failure: in this case it will activate the RUP alarm

Unit missing(RUM)

S–161

S–161NInsert missing unit

Unit Problem(RUP)

S–161N

S–161ND

L–161

L–161N

Replace unit

Unit type mismatch(RUTM)

L–161N

L–161ND

L–162

Insert right unit (unit inserted into a slot set with another type ofunit)

High LaserTemperature(HLT)

L–162

L–162N

L–162ND

I–161NDReplace unit

Cooling Fans Failure(CFF)

FAN

Check the fan units and substitute the faulty one

Unit missing(RUM)

FAN

Insert missing unit

Page 524: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

28

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

MAINTENANCEBOARDACRONYM

NAME AND

ACRONYM

OF DISPLAYEDALARM

Unit missing(RUM)

Insert missing unit

Unit Problem(RUP)

Replace unit

Unit type mismatch(RUTM)

CONGI

Insert right unit (unit inserted into a slot set with another type ofunit)

LAN problem(LAN)

CONGIThis alarm type is present only on 1650SMC or 1660sm.Check LAN interconnection or substitute CONGI unit

Battery Failure(BF)

According to the CONGI slot check the station battery. (Battery A or Battery B)

Fuse Failure(FF)

Substitute the fuse on the CONGI unit.

Unit missing(RUM)

Insert missing unit

Unit Problem(RUP)

Replace unit

Unit type mismatch(RUTM) SERGI

Insert right unit (unit inserted into a slot set with another type ofunit)

Battery Failure(BF)

Check the Station Battery connected to the unit

Fuse Failure(FF)

Substitute the fuse on the CONGI unit.

Page 525: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

29

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Table 8. Module alarm

NAME AND

ACRONYM

OF DISPLAYEDALARM

MODULEACRONYM

MAINTENANCE

UnconfiguredEquipment Present(UEP)

ICMI

IS–1.1

IL–1.1

IL–1.2

MM1

IS–4.1

IL–4.1

IL–4.2

1000B

1000B

100B

OH–I

OL–IN

OH–MM

OL–MM

SS–162E

SL–162E

SS–162C

SL–162C

SL–162

SL–161

SI–161

SS–161

Unit inserted but not configured; Configure the board.

Page 526: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

30

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.5 Port View alarms

It is also possible to analyze the detailed alarm presence on the TPs of each ports of the NE, followingthe indication of the Port View chapter on the previous Section of this Handbook.

Figure 8. to Figure 12. are examples of Port view.For each TP of the Port a detail of the relevant alarms is presented.

On the port view the messages displayed at the bottom provide information about:

– MSP protection (if enable); refer to Figure 9.

– Automatic Laser Shutdown state; refer to Figure 8.

– State of the connection for Ethernet port (available only if an ethernet port has been selected); referto Figure 11. and Figure 12.

A message under the mouse indicator provides the name of the alarm or object on which it is located, inthis way facilitating the identification of the alarm or status or object.

The non–alarmed condition of an alarm icon is represented by a green color and a “–” sign in the box.The alarmed condition is represented by the color of its severity (as assigned by the ASAP) and an “X”sign in the box.

The alarms which can be found in the Port view are listed in Table 7. on page 25, where the relevantmaintenance actions are reported too.

The information regarding ALS states and Laser state useful for operators safety purpose arereported in the following:

ALS states:

Inactive = No ALS has been activated (Off) or the laser has been Forced ON/OFF.

In test = The laser restart has been automatically activated .

Active = The ALS has been activated (On).

Undefined = The ALS is not present (not created).

Laser state:

On = all OK or ALS not present (not created).

Off = Laser off (when ALS is created).

Forced on = ALS forced on by operator command.

Forced off = ALS forced off by operator command.

Page 527: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

31

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Alarms

Protection message

Mouse message

TP’s

Alarms

Figure 8. Example of SDH Port View alarms (without MSP schema)

Page 528: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

32

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Alarms

Mouse message

TP’s

Alarms

MSP Iinformation message

Figure 9. Example of SDH Port View alarms (with MSP schema)

Page 529: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

33

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Alarms

Mouse message

TP’s

Figure 10. Example of ATM Port View alarms

Page 530: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

34

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Alarms

Mouse message

TP’s

State of connection for Ethernet port

LCA

Figure 11. Example of 10/100 Mbit/s Ethernet Port View alarms

Page 531: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

35

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Alarms

Mouse message

TP’s

State of connection for Ethernet port

TP’s

Alarms

LCA

Figure 12. Gigabit/s Ethernet Port View alarms

Page 532: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

36

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Page 533: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

37

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.6 Board view alarms and states

The alarm and status indications at Board level can be obtained, following the indication of the Board Viewchapter on the previous Section of this Handbook.

Figure 14. and Figure 15. are examples of Board view.

The alarm and status indications depend on the unit type; for example SDH units is organized on two levelsof presentation (in the first is selected one of the available ports) and each view contains dedicated indica-tions.An alarm box is displayed on each port, to indicate whether the port is alarmed.

An indication in the ”message/status area” provides information about the board Administrative State: “in–service” or “out–of–service”.

The alarms of the board are reported at the bottom of the ”message/status area”, by means of variousboxes containing relevant acronyms.The non–alarmed condition of an alarm icon is represented by a green color.The alarmed condition is represented by the color of its severity (as assigned by the ASAP).

A message under the mouse indicator provides the name of the alarm or object on which it is located, inthis way facilitating the identification of the alarm or status or object.

In the view is present the Administrative State information: “in service” or “out of service”.

The alarms which can be found in the Board view are listed in Table 6. page 24, where the relevant mainte-nance actions are reported too.

In the view can also be present EPS indications (if supported by the equipment)

Sub–board alarms

In case of board with multi access points (i.e. containing “sub–boards”) another view permits to select thecontained port, named “daughter” or “sub–board” (see example of Figure 14. page 38).

An example of “daughter” (sub–board) view with the presented ports is in Figure 13. on page 38. It is dis-played after clicking on it.

The alarms which can be found in the sub–board view are listed in Table 6. page 24, where the relevantmaintenance actions are reported too.

Page 534: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

38

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

port alarm synthesis

Board alarms

Administrative State

”daughters”

Figure 13. Example of board view alarms and status

port alarm synthesis

Board alarms

Administrative State

Figure 14. Example of “daughter” View alarms and status

Page 535: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

39

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Board alarms

Administrative StateEPS State

Figure 15. Example of PDH Board View alarms and status

Page 536: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

40

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.7 Subrack and Rack view alarms

The alarms and status indications at subrack and rack level can be obtained, following the indicationsgiven on the previous Section of this Handbook (”NE management”).

Figure 16. and Figure 17. are examples of Subrack and Rack view.

An alarm box is displayed on each board, to indicate whether the board is alarmed. This board alarm sum-marization is activated when one of the board alarms (those reported at the bottom of the Board view) isactive.

A “lock” symbol on a board indicates that it is “in–service”. Else, the lack of this symbol indicates its “out–of–service” state . (Administrative State information).

A message under the mouse indicator provides the name of the alarm or object on which it is located, inthis way facilitating the identification of the alarm or status or object.

Severity alarmssynthesis

Message/status area

View area

View title

Domain alarms synthesis

Management status control panel

Menu bar

Administrativestate indications

Boards

Alarms

LCA

Figure 16. 1660SM Subrack view alarms and status example

Page 537: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

41

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Severity alarmssynthesis

Message/status area

View area

View title

Domain alarms synthesis

Management status control panel

Menu bar

Administrativestate indications

Fans subrack

Alarms

LCA

Figure 17. 1660SM Rack view alarm and status example

Page 538: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

42

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.7.1 Fans Subrack alarms view

This option is only available on 1650SMC and 1660SM.

To obtain Fan Subrack alarms indications click twice with the mouse on the relevant subrack drawingin the rack level view.

Figure 18. on page 42 is presented:

– Battery Failure (BF): check that the station battery cables are right connected

– Cabling Problem (CAP): check that the alarms cable between the Fans Subrack and the CONGIunit is right connected; check also the configuration in the Equipmentmenu (Connected FAN to CONGI#10 for 1660SM or Connected FAN toCONGI#5 for 1650SMC)

Fans subrack can only be connected to CONGI#10 in 1660SMand CONGI#5 in 1650SMC.

– Temperature Out of Range (TOOR): verify the Fan unit alarm and in presence of faulty substitute therelevant unit; clean also the Dust filter if necessary.

Figure 18. 1660SM Fans subrack alarms view example

Page 539: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

43

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.8 AC/DC Rectifier alarms view

This option is available only for 1640FOX

The alarms indications of the AC/DC Rectifier (SR40R) can be obtained selecting, on the menu bar, theitems: Views > Equipment and then by double clicking on the body of the SR40R, displayed beneaththe SR40M .Figure 19. shows the SR40R alarms view, where the following alarms indications are displayed:

– RLV (Rectifier Low Voltage): it indicates loss of AC power –––> Check AC connection.– BC (Battery Charging).– RCF (Rectifier Failure): it indicates internal fault, or fans failure –––>

if the remote alarm “FANSOFF2” is active, then replace the rectifier fans, asstated in Technical Handbook.otherwise, if the remote alarm “FANSOFF2” is not active, then replace the AC/DC Rectifier (in this case all the traffic will be lost).

– BD (Battery Degraded) –––> replace the batteries, as stated in Technical Handbook.– RUM (Replaceable Unit Missing) –––> check the Rectifier alarms connection.

Rectifier alarms

LCA

Figure 19. AC/DC Rectifier View alarms and status

Page 540: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

44

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.9 Equipment View alarms

3.4.9.1 1660SM equipment view alarms

The alarm indications at Equipment level can be obtained, following the indication of the Equipment Viewchapter on the previous Section of this Handbook.

Figure 20. shows the Equipment view, with the alarm indications presented:

– Fuse Failure (FF): Substitute the fuse in the CONGI unit and search for a cause.

– AND Battery Failure (ABF): Failure of the Service Power Supply connected to the CONGI Rackconnector.

– Backplane Failure (BKF): Substitute the Termination BUS

– Specific Hardware Diagnostic (SHD): Indicate the presence of link failure between the MATRIX andone of the units; for details choose the Internal Link Monitor option of theDiagnosis menu.

These alarms can be observed at OS level.

Equipment alarms

Figure 20. Example of Equipment View alarms and status

Page 541: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

45

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.9.2 1650SMC equipment view alarms

The alarm indications at Equipment level can be obtained, following the indication of the Equipment Viewchapter on the previous Section of this Handbook.

Figure 20. shows the Equipment view, with the alarm indications presented:

– Fuse Failure Substitute the fuse in the CONGI or SERGI unit and search for a cause.

– AND Battery Failure Failure of the Service Power Supply connected to the CONGI Rack connector.

– Specific Hardware Diagnostic (SHD): Indicate the presence of link failure between the SYNTH1N /SYNTH4.ADM and one of the units; for details choose the Internal Link Monitoroption of the Diagnosis menu.

These alarms can be observed at OS level.

Equipment alarms

Figure 21. Example of 1650SMC Equipment View alarms and status

Page 542: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

46

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.9.3 1640FOX equipment view alarms

The alarms indications at Equipment level can be obtained selecting, on the menu bar, the items:Views > Equipment and then Equipment > Show Supporting Equipment.

Figure 22. shows the Equipment view, where the following alarms indications are displayed(FF, ABF, BKF alarms are not used):

– Cooling Fans Failure (CFF) Substitute the fans of the 1640FOX, as explained in the “1640FOX Technical Handbook”.

– Specific Hardware Diagnostic (SHD): it indicates the presence of link failure betweenthe SYNTH1N /SYNTH4 unit and one of the other units; for details checkthe fault by means of the Internal Link Monitor option of the Diagnosismenu.

Equipment alarms

Figure 22. Example of 1640FOX equipment View alarms and status

Page 543: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

47

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

3.4.10 External Points alarms (HouseKeepings)

The alarms and status indications relevant to External Points (housekeepings) can be obtained, followingthe indication of the External Points chapter on the previous Section of this Handbook.

The external state represents the alarm state. ”On” when the alarm is raised, else ”Off”.If the external point is active (On), a red flag is represented near the state of the concerned point.

In case of input point the alarm state is reported also in the user label column, by the box near its name:green color and sign “–” –––> means non–alarmed condition.the change of color, as assigned by the severity (ASAP) –––> means alarmed condition.

Figure 23. Example of External Points alarms and status

Page 544: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

48

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Page 545: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

49

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

4 UNIT REPLACEMENT WITH A SPARE

No particular indication is given as to spare handling which is left to the Maintenance Administration.

The replacement procedures are executed as follows:

– Hardware set the spare unit exactly as the unit to replace. Settings are specified in the MS docu-ments. Here a layout figure indicates the exact location of all the setting arrangements and a tablerelate the operations to achieve with the settings.The cited documents are enclosed in the Technical Handbook.

– Simply replace those units not provided with any software settings

– With regard to the EQUICO / PQ2/EQC unit refer to paragraph 4.1 on page 50.(Only for 1660SM)

– With regard to the COMPACT ADM (also called SYNTH1, SYNTH1N, SYNTH4) unit refer to para-graph 4.2 on page 52.(Only for 1650SMC and 1640FOX)

– With regard to the ATM MATRIX 4X4 and 4x4 V2 units refer to paragraph 4.3 on page 56.

– With regard to the ATM MATRIX 8X8 unit refer to paragraph 4.4 on page 58.(Only for 1660SM)

– With regard to the ISA–PR MATRIX and ISA–PR_EA MATRIX unit refer to the specific Operator’sHandbook.

– With regard to the ISA–ES unit refer to the specific Operator’s Handbook.

– When upgrading an equipment with “New Hardware” (for example MATRIXN unit) that substitute theold units (for example MATRIX unit), follow the indication given in paragraph 5 on page 59.

– With regard to the CONGI unit refer to paragraph 4.5 on page 58.(Only for 1660SM and 1650SMC)

WARNING!:

When substituting the CONGI unit strictly observe the following procedure:

• In order to avoid short–circuit, before substituting the CONGI unit, switch–off the rele-vant Station battery fuse breaker . Subsequently remove the Station Battery cableand extract the CONGI unit.

• Before inserting the new spare unit carefully check the settings and the integrity ofthe relative connectors.Don’t insert the units that have been damaged during the transport/storing or in aphase before their replacing.

• Insert the new CONGI unit in the subrack without the Station Battery cable connetedto it.

• Connect the Station Battery cable to the power connector present in front of theCONGI board.

• Switch–on the relevant Station battery fuse breaker .

Page 546: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

50

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

4.1 EQUICO or PQ2/EQC unit replacement

EQUICO unit can be equipped only in 1660SM Rel.4.3

PQ2/EQC unit can be equipped only in 1660SM Rel 5.1

Various procedures are utilized to replace a EQUICO or PQ2/EQC faulty unit. They depend on the typeof spares available:

• Spare without software installed. This is the normal condition.

• Spares with installed software, belonging to the same type of equipment and with SW releaseidentical to the unit to replace

• Spares with installed software, belonging to the same type of equipment but with SW releasediffering from the one of the unit to replace, or belonging to other types of equipment or un-known.

• Spares with installed software, belonging to the another type of equipment (example 1670SM)or unknown SW.

– CONGI unit version (read NOTE in Figure 24. on page 51)

– MIB store in the Craft Terminal or O.S.

The flow–chart of Figure 24. on page 51 illustrates the procedures to follow for the EQUICO or PQ2/EQCsubstitution.

The procedure aim is to replace the faulty unit without causing configuration changes and/or unwantedfaults; when not possible this is indicated in the flow chart.

Page 547: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

51

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

Download the NE relevant software releasewith SIBDL procedure

(see SIBDL section)

software of the same

END

Download the NE relevant software release

(see NE management section)with normal dowload procedure.

”Activate” the sent MIB

I1–1 OFF I1–2 OFF

INSERT AGAIN THE NEWEQUICO or PQ2/EQC

NOTES:

NB2: The ”Comm/Routing” tables are automatically retrievedonly with CONGI starting from version 3AL 78830AAACOtherwise the ”Comm/Routing” tables must be configurated manually using the Craft Terminal

Is the MIB storedin the Craft Terminal?

YESNO

MIB containing the correctconfiguration (NB1)

From O.S. send the saved

MIB containing the correctconfiguration (NB1)

From C.T. send the saved

(see NE management section)

”Activate” the sent MIBFrom O.S.

From C.T.

NEW UNIT HW

I1–1 ON I1–2 OFF

HW–PRESET THE NEW UNIT WITH:

I1–1 OFF I1–2 ON

REMOVE AND HW PRESET THE NEW UNIT WITH:

Substitute EQUICO orPQ2/EQC unit

NB1

INSERT THE NEW UNIT

INSERT THE NEW UNIT AGAIN

(Reset Data Base)

(Reset Data Base and upload Comm/Routing Tables)

REMOVE AND HW PRESET THE NEW UNIT WITH:(Normal operating condition)

CONDITION:

release and NE

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with different

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit without

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with wrong or

NEW UNIT HWCONDITION:

unknown software

I1–1 ON I1–2 ONREMOVE AND HW PRESET THE NEW UNIT WITH:

INSERT THE NEW UNIT AGAIN

THIS PROCEDURE IS APPLICABLE ONLY ON

1660SM

Figure 24. EQUICO or PQ2/EQC unit replacement

Page 548: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

52

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

4.2 COMPACT ADM unit replacement

COMPACT ADM unit can be equipped only in 1640FOX and 1650SMC.

N.B. In this paragraph for COMPACT ADM is generically intended one of the following unit:

– SYNTH1

– SYNTH1N

– SYNTH4

Various procedures are utilized to replace a COMPACT ADM faulty unit. They depend on the followingmaintenance conditions:

– EPS protection of the COMPACT ADM unit (only for 1650SMC)

• EPS present or not (typically present)• failure on the Main board• failure on the Spare board

– type of spares available:

• Spare without software installed. This is the normal condition.• Spares with installed software, belonging to the same type of equipment and with SW release

identical to the unit to replace.• Spares with installed software, belonging to the same type of equipment but with SW release

differing from the one of the unit to replace, or belonging to other types of equipment or un-known.

• Spares with installed software, belonging to the another type of equipment or unknown SW.

– CONGI unit version (read NOTES in Figure 26. on page 54 and Figure 27. on page 55)

– MIB store in the Craft Terminal or O.S.

The flow–charts of Figure 25. on page 53, Figure 26. on page 54, Figure 27. on page 55 illustrates theprocedures to follow for the COMPACT ADM substitution.

The procedure aim is to replace the faulty unit without causing configuration changes and/or unwantedfaults; when not possible this is indicated in the flow chart.

Replacement problems:

When replacing the COMPACT ADM unit the traffic of the two SDH ports is lost when not SNCPprotected.Then it is suggested to replace in low traffic condition.

Page 549: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

53

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

PROTECTEDCOMPACT ADM unit

FAILUREON SPARE

FAILUREON MAIN

SubstituteCOMPACT ADM

END

Craft TerminalYESNO

Force EPS on spareCOMPACT ADM

Substitute mainCOMPACT ADM

manages the NE?

HW–PRESET THE NEW UNIT WITH:I1–1 OFF I1–2 ON

INSERT THE NEW UNIT

WAIT UNTIL THE ACCESS WILL BE RETURNED TO THE C.T.

(Reset Data Base)

THIS PROCEDURE IS APLLICABLE ONLY TO

1650SMC

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

Download the NE relevant software releasewith SIBDL procedure

(see SIBDL section)

software of the same

Download the NE relevant software release

(see NE management section)with normal dowload procedure.

NEW UNIT HWCONDITION:

release and NE

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with different

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit without

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with wrong or

NEW UNIT HWCONDITION:

unknown software

I1–1 ON I1–2 ONREMOVE AND HW PRESET THE NEW UNIT WITH:

INSERT THE NEW UNIT AGAIN

CONTINUEREFER TO

Figure 26. on page 54

Figure 25. COMPACT ADM unit replacement (EPS protected) part “A”

Page 550: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

54

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

IN CASE OF EPS THE DECISION

COMPACT ADM IS LEFT TO THE OPERATOR

END

”Activate” the sent MIB

I1–1 OFF I1–2 OFF

INSERT THE NEWCOMPACT ADM

NOTE:

only with CONGI starting from version 3AL 78830AAACOtherwise the ”Comm/Routing” tables must be configurated manually using the Craft Terminal

Is the MIB storedin the Craft Terminal?

YESNO

MIB containing the correctconfiguration (NB1)

From O.S. send the saved MIB containing the correctconfiguration (NB1)

From C.T. send the saved

(see NE management section)

”Activate” the sent MIBFrom O.S. From C.T.

HW–PRESET THE NEW UNIT WITH:I1–1 ON I1–2 OFF

TO FORCE OR NOT TO THE main

REMOVE AND

NB1: The ”Comm/Routing” tables are automatically retrieved

INSERT THE NEW UNIT AGAIN

HW–PRESET THE NEW UNIT WITH:REMOVE AND(Normal operating condition)

(Reset Data Base and upload Comm/Routing Tables)

FROM

CONTINUE

Figure 25. on page 53

THIS PROCEDURE IS APLLICABLE ONLY TO

1650SMC

Figure 26. COMPACT ADM unit replacement (EPS protected) part “B”

Page 551: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

55

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

NOT PROTECTEDCOMPACT ADM unit

END

NB1: with not protected Compact ADM all traffic is lost

”Activate” the sent MIB

I1–1 OFF I1–2 OFF

INSERT THE NEWCOMPACT ADM

NOTES:

NB2: The ”Comm/Routing” tables are automatically retrievedonly with CONGI starting from version 3AL 78830AAACOtherwise the ”Comm/Routing” tables must be configurated manually using the Craft Terminal

Is the MIB storedin the Craft Terminal?

YESNO

MIB containing the correctconfiguration (NB2)

From O.S. send the saved

MIB containing the correctconfiguration (NB2)

From C.T. send the saved

(see NE management section)

”Activate” the sent MIBFrom O.S.

From C.T.

I1–1 ON I1–2 OFF

HW–PRESET THE NEWI1–1 OFF I1–2 ON

UNIT WITH:

REMOVE AND HW–PRESET THE NEW UNIT WITH:

Substitute mainCOMPACT ADM (NB1)

INSERT THE NEW UNIT

INSERT THE NEW UNIT AGAIN

REMOVE AND HW–PRESET THE NEW UNIT WITH:

WAIT UNTIL THE ACCESS WILL BE RETURNED TO THE C.T.

(Reset Data Base)

(Normal operating condition)

(Reset Data Base and upload Comm/Routing Tables)

THIS PROCEDURE IS APLLICABLE ONLY TO

1650SMC AND 1640FOX

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

Download the NE relevant software releasewith SIBDL procedure

(see SIBDL section)

software of the same

Download the NE relevant software release

(see NE management section)with normal dowload procedure.

NEW UNIT HWCONDITION:

release and NE

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with different

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit without

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with wrong or

NEW UNIT HWCONDITION:

unknown software

I1–1 ON I1–2 ONREMOVE AND HW PRESET THE NEW UNIT WITH:

INSERT THE NEW UNIT AGAIN

Figure 27. COMPACT ADM unit replacement (EPS not protected)

Page 552: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

56

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

4.3 ATM MATRIX 4X4, 4x4 V2, 4X4 D3 units replacement

Two different procedure are available for ATM MATRIX 4X4 substitution according to the EPS schema.

ATM MATRIX 4X4 EPS schema is not supported by 1640FOX so, the flow chart of Figure 29. cannot be applied to this equipment.

The flow–charts of Figure 28. on page 56 illustrates the procedures to follow for the ATM MATRIX 4X4when it is not EPS protected.

The flow–charts of Figure 29. on page 57 illustrates the procedures to follow for the ATM MATRIX 4X4when it is EPS protected.

The procedures aim is to replace the faulty unit without causing configuration changes and/or unwantedfaults.

NOT EPS PROTECTEDATM MATRIX unit

END

From ATM Craft application ”Restore” the data dase

I1–4 OFF

HW–PRESET THE NEW

I1–4 ON

UNIT WITH:

REMOVE AND HW–PRESET THE NEW UNIT WITH:

Substitute the faulty unit

INSERT THE NEW UNIT ANDWAIT UNTIL THE ACCESS

WILL BE RETURNED TO THE C.T.

with a spare ATM MATRIX

TO RESET THE DATA BASE

INSERT THE NEW UNIT ANDWAIT UNTIL THE ACCESS

WILL BE RETURNED TO THE C.T.

previously saved (see ” ATM OPERATOR’S HANDBOOK)

or otherwise re–configure all the ATM connections

Figure 28. ATM MATRIX 4X4 and 4x4 V2 units replacement without EPS protection

Page 553: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

57

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

EPS PROTECTEDATM MATRIX unit

END

The ”Spare ” unit become active

FAILUREON SPARE

FAILUREON MAIN

SubstituteATM MATRIX unit

END Substitute the faulty uni

THIS PROCEDURE IS APLLICABLE ONLY TO

1650SMC AND 1660SM

Figure 29. ATM MATRIX 4X4 unit replacement with EPS protection

Page 554: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

58

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

4.4 ATM MATRIX 8X8 unit replacement

ATM MATRIX 8X8 unit can be equipped only in 1660SM.

Two different procedure are available for ATM MATRIX 8X8 substitution according to the EPS schema.

For ATM MATRIX 8X8 substitution can be applied the same rules used for ATM MATRIX 4X4 , so referto flow chart of Figure 28. on page 56 and Figure 29. on page 57.

4.5 CONGI unit replacement

CONGI unit can be equipped only on 1660SM and 1650SMC.

When substituting an “old” CONGI unit (from code 3AL 78830 AAAA to code 3AL 78830 AAAE) with a“new” CONGI unit (starting from code 3AL 78830 AAAF) must be taken into account the rules reportedin the following; this is necessary for the right management of the “Fuse Broken” alarm on the CONGI(1650SMC and 1660SM) and SERGI (1650SMC) units.

[1] The alarm “Fuse Broken” is meaningful (hence it is active) only if two batteries connections (thismeans that two CONGI in1660SM or one CONGI and one SERGI in 1650SMC has been equipped)are present.

[2] If “old” CONGI units are present in main slot (slot 10 for 1660SM and slot 4 for 1650SMC) it is manda-tory to connect the service battery to the front connector (refer to Installation Handbook for details)to correctly activate the alarms.

[3] In presence of configurations having 2 CONGI units composed of an “old” and “new” type it is manda-tory to open TC5 setting (refer to Technical Handbook for details on Hardware settings) on the solder-ing side of the “old” type CONGI if the latter is placed in the spare position (slot 12 in 1660SM andslot 5 in 1650SMC).If the “old” CONGI is maintained in a main slot (slot 10 in 1660SM and slot 4 in 1650SMC), TC5 canbe nevertheless closed or open.

Page 555: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

59

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

5 UPGRADING WITH NEW HARDWARE

In the next paragraphs is indicated the procedure to follow when upgrading an equipment with “New Hard-ware” .

The new Hardware is identify by the “N” letter at the end of the acronym unit (for example MATRIXN isthe new version, MATRIX without “N” is the old version).

This procedure permits, if the equipment is EPS protected and inserted in a protected network (linear orring protection), to maintain the system “in service”

Page 556: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

60

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

5.1 MATRIX substitution with MATRIXN

MATRIX unit can be equipped only in 1660SM Rel. 4.3.

According to the MATRIX EPS protection scheme different procedure are available:

[1] Upgrading with a new MATRIXN EPS not protected

Substituting the old MATRIX all the traffic is lost!

• Remove the old MATRIX in slot 23 from the subrack

• Insert the new MATRIX into the subrack slot 23; on Craft Terminal a RUTM (unit type mismatch)alarm will be present.

• On Craft Terminal in the Subrack level view select the slot where the new unit has been inserted

• Select the Modify option from the Equipment menu and select the acronym of the new unit( MATRIXN) from the list, then click on ok.

• Verify that the RUTM alarm disappear

[2] Upgrading with a new MATRIXN EPS protected

• Remove first the Stand–by MATRIX from the subrack

• Insert the new MATRIXN into the subrack slot previously occupied by the old MATRIX; a RUTM(unit type mismatch) alarm will be present.

• On Craft Terminal in the Subrack level view select the slot where the new unit has been inserted

• Select the Modify option from the Equipment menu and select the MATRIXN acronym fromthe list then click on ok.

• Verify that the RUTM alarm disappear

• Force the EPS Switching to the Stand–by MATRIXN by selecting the Switch option from theEPS menu. For details see the paragraph “Switching EPS” in the “NE MANAGEMENT” sectionof this Handbook.

• After having verify that the MATRIXN (previously in Stand–by) is now working, remove the MA-TRIX unit (previously working) from the subrack.

• Insert the new MATRIXN into the subrack slot previously occupied by the old MATRIX; a RUTM(unit type mismatch) alarm will be present.

• On Craft Terminal in the Subrack level view select the slot where the new unit has been inserted

• Select the Modify option from the Equipment menu and select the MATRIXN acronym fromthe list then click on ok.

• Verify that the RUTM alarm disappear

• The decision to force again the EPS MATRIXN switching to restore the original working condi-tion is left to the operator.

Page 557: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

61

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

5.2 SYNTH1 substitution with SYNTH1N

5.2.1 Procedure for 1650SMC

According to the EPS and SNCP SYNTH1 protection scheme different procedure are available:

[1] Upgrading with a new SYNTH1N EPS not protected

Substituting the old SYNTH1 all the traffic is lost!

• Remove the old SYNTH1 in slot 9 from the subrack

• Before inserting the new SYNTH1N in subrack slot 9, follow the instruction described inFigure 30. on page 62. At the end of the procedure a RUTM (unit type mismatch) alarm will bepresent.

• On Craft Terminal in the Subrack level view select the SYNTHN unit in slot 9

• Select the Modify option from the Equipment menu and select the SYNTH1N acronym fromthe list then click on ok.

• Verify that the RUTM alarm disappear

Page 558: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

62

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

END

”Activate” the sent MIB

I1–1 OFF I1–2 OFF

INSERT THE NEWCOMPACT ADM

NOTES:

only with CONGI starting from version 3AL 78830AAACOtherwise the ”Comm/Routing” tables must be configurated manually using the Craft Terminal

Is the MIB storedin the Craft Terminal?

YESNO

MIB containing the correctconfiguration (NB1)

From O.S. send the saved

MIB containing the correctconfiguration (NB1)

From C.T. send the saved

(see NE management section)

”Activate” the sent MIBFrom O.S.

From C.T.

I1–1 ON I1–2 OFF

HW–PRESET THE NEWI1–1 OFF I1–2 ON

UNIT WITH:

REMOVE AND HW–PRESET THE NEW UNIT WITH:

INSERT THE NEW UNIT

INSERT THE NEW UNIT AGAIN

REMOVE AND HW–PRESET THE NEW UNIT WITH:

WAIT UNTIL THE ACCESS WILL BE RETURNED TO THE C.T.

(Reset Data Base)

(Normal operating condition)

(Reset Data Base and upload Comm/Routing Tables)

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

Download the NE relevant software releasewith SIBDL procedure

(see SIBDL section)

software of the same

Download the NE relevant software release

(see NE management section)with normal dowload procedure.

NEW UNIT HWCONDITION:

release and NE

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with different

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit without

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with wrong or

NEW UNIT HWCONDITION:

unknown software

I1–1 ON I1–2 ONREMOVE AND HW PRESET THE NEW UNIT WITH:

INSERT THE NEW UNIT AGAIN

NB1: The ”Comm/Routing” tables are automatically retrieved

Figure 30. 1650SMC: Upgrading with a new SYNTH1N EPS not protected

Page 559: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

63

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

[2] Upgrading with a new SYNTH1N EPS protected

Supposing that the two STM–1 ports are not network protected, their traffic will be lost during thesubstitution; the traffic of all the other board will not be lost.

• Remove first the old SYNTH1 in slot 10 from the subrack

• Insert the new SYNTH1N into the subrack slot 10; a RUTM (unit type mismatch) alarm will bepresent.

• On Craft Terminal in the Subrack level view select the SYNTH1N unit in slot 10

• Select the Modify option from the Equipment menu and select the SYNTH acronym from thelist then click on ok.

• Verify that the RUTM alarm disappear

• Force the EPS Switching on SYNTH1N in slot 10 by selecting the Switch option from the EPSmenu. For details see the paragraph “Switching EPS” in the “NE MANAGEMENT” section ofthis Handbook.

• Remove the old SYNT1H in slot 9 from the subrack

• Before inserting the new SYNTH1N in subrack slot 9, follow the instruction described inFigure 31. on page 64. At the end of the procedure a RUTM (unit type mismatch) alarm will bepresent.

• On Craft Terminal in the Subrack level view select the SYNTH1N unit in slot 9

• Select the Modify option from the Equipment menu and select the SYNTH1N acronym fromthe list then click on ok.

• Verify that the RUTM alarm disappear

Page 560: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

64

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

HW–PRESET THE NEW UNIT WITH:I1–1 OFF I1–2 ON

INSERT THE NEW UNIT

WAIT UNTIL THE ACCESS WILL BE RETURNED TO THE C.T.

(Reset Data Base)

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

Download the NE relevant software releasewith SIBDL procedure

(see SIBDL section)

software of the same

Download the NE relevant software release

(see NE management section)with normal dowload procedure.

NEW UNIT HWCONDITION:

release and NE

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with different

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit without

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with wrong or

NEW UNIT HWCONDITION:

unknown software

I1–1 ON I1–2 ONREMOVE AND HW PRESET THE NEW UNIT WITH:

INSERT THE NEW UNIT AGAIN

IN CASE OF EPS THE DECISION

COMPACT ADM IS LEFT TO THE OPERATOR

END

”Activate” the sent MIB

I1–1 OFF I1–2 OFF

INSERT THE NEWCOMPACT ADM

Is the MIB storedin the Craft Terminal?

YESNO

MIB containing the correctconfiguration (NB1)

From O.S. send the saved MIB containing the correctconfiguration (NB1)

From C.T. send the saved

(see NE management section)

”Activate” the sent MIBFrom O.S. From C.T.

HW–PRESET THE NEW UNIT WITH:I1–1 ON I1–2 OFF

TO FORCE OR NOT TO THE main

REMOVE AND

INSERT THE NEW UNIT AGAIN

HW–PRESET THE NEW UNIT WITH:REMOVE AND(Normal operating condition)

(Reset Data Base and upload Comm/Routing Tables)

NOTES:

only with CONGI starting from version 3AL 78830AAACOtherwise the ”Comm/Routing” tables must be configurated manually using the Craft Terminal

NB1: The ”Comm/Routing” tables are automatically retrieved

Figure 31. 1650SMC: Upgrading with a new SYNTH1N EPS protected

Page 561: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

65

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

5.2.2 Procedure for 1640FOX

Substituting the old SYNTH all the traffic is lost!

• Remove the old SYNTH in slot 2 from the subrack

• Before inserting the new SYNTHN in subrack slot 2, follow the instructions described inFigure 32. on page 66 (Compact ADM replacement). At the end of the procedure a RUTM (unittype mismatch) alarm, relevant to the replaced unit, will be present on the C.T.

• On Craft Terminal, in the Subrack level view, select the Compact ADM unit (slot 2).

• Select the Modify option from the Equipment menu and select the SYNTHN acronym fromthe list then click on ok.

• Verify that the RUTM alarm disappears.

Page 562: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

66

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

END

”Activate” the sent MIB

I1–1 OFF I1–2 OFF

INSERT THE NEWCOMPACT ADM

NOTE:

Is the MIB storedin the Craft Terminal?

YESNO

MIB containing the correctconfiguration (NB1)

From O.S. send the saved

MIB containing the correctconfiguration (NB1)

From C.T. send the saved

(see NE management section)

”Activate” the sent MIBFrom O.S.

From C.T.

I1–1 ON I1–2 OFF

HW–PRESET THE NEWI1–1 OFF I1–2 ON

UNIT WITH:

REMOVE AND HW–PRESET THE NEW UNIT WITH:

INSERT THE NEW UNIT

INSERT THE NEW UNIT AGAIN

REMOVE AND HW–PRESET THE NEW UNIT WITH:

WAIT UNTIL THE ACCESS WILL BE RETURNED TO THE C.T.

(Reset Data Base)

(Normal operating condition)

(Reset Data Base and upload Comm/Routing Tables)

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

Download the NE relevant software releasewith SIBDL procedure

(see SIBDL section)

software of the same

Download the NE relevant software release

(see NE management section)with normal dowload procedure.

NEW UNIT HWCONDITION:

release and NE

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with different

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit without

NEW UNIT HWCONDITION:

software

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

unit with wrong or

NEW UNIT HWCONDITION:

unknown software

I1–1 ON I1–2 ONREMOVE AND HW PRESET THE NEW UNIT WITH:

INSERT THE NEW UNIT AGAIN

NB1: The ”Comm/Routing” tables are automatically retrieved(from the shelf of the equipment)

Figure 32. 1640FOX: Upgrading with a new SYNTH1N

Page 563: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

67

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

5.3 P4S1, S–41, L–41, L–42, S–161, L–161, L–162 substitution with P4S1N,S–41N, L–41N, L–42N , S–161N, L–161N, L–162N

During the substitution the traffic carried by the units will be lost if not SNCP or MSP protected

In the following an example will be given substituting a P4S1 with a P4S1N; the same procedure canbe applied to substitute the S–41, L–41, L–42, S–161, L–161, L–162 units respectively with S–41N,L–41N, L–42N , S–161N, L–161N, L–162N units; the same procedure can be applied to substitutea generic “xyz” unit with its upgraded “xyzN” version.

• Remove the old unit( example P4S1 ) from the subrack

• Insert the new unit (example P4S1N) into the subrack slot previously occupied by the old unit;on Craft Terminal a RUTM (unit type mismatch) alarm will be present.

• On Craft Terminal in the Subrack level view select the slot where the new unit has been inserted

• Select the Modify option from the Equipment menu and select the acronym of the new unit( in our example P4S1N) from the list, then click on ok.

• Verify that the RUTM alarm disappear

5.4 P21E1 substitution with P21E1N (only for 1640FOX)

During the substitution, the traffic carried by the involved units will be lost.

In the following an example will be given, substituting a P21E1 with a P21E1N; the same procedurecan be applied to substitute a generic “xyz” unit with its upgraded “xyzN” version.

• Remove the old unit (example P21E1) from the subrack.

• Insert the new unit (example P21E1N) into the subrack slot previously occupied by the old unit;on Craft Terminal a RUTM (unit type mismatch) alarm, relevant to the replaced unit, will be pres-ent.

• On Craft Terminal, in the Subrack level view, select the slot where the new unit has been in-serted.

• Select the Modify option from the Equipment menu and select the acronym of the new unit(in our example P21E1N) from the list, then click on ok.

• Verify that the RUTM alarm disappears.

Page 564: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

68

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Page 565: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

69

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

6 FLASH CARD SUBSTITUTION

6.1 Flash card substitution procedure for 1660SM

The FLASH card used up to rel. 2.0A (80 Mbytes) requires to be replaced with one having a higher size(256 Mbyte) in order to manage the new SDH+ISA (Integrated Service Adapter) services.

N.B. Before to start with the FLASH card substitution ( flow–chart of Figure 33. on page 70) executethe following instruction:

a ) Save the MIB as explained in Section 3 (NE MANAGEMENT), Paragraph “Mib manage-ment” of this Manual.

b ) Create and install the enhanced software package (SDH+ISA) as explained in “1320 CTBasic Operator’s Handbook”.

The flow–chart of Figure 33. on page 70 illustrates the procedures to follow for the FLASH card substitu-tion without causing loss of traffic.

Page 566: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

70

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Download the NE relevant software packagewith SIBDL procedure

(see SIBDL section)

END

”Activate” the sent MIB

I1–1 OFF I1–2 OFF

INSERT AGAIN THE EQUICOOR PQ2/EQC IN THE SUBRACK

NOTES:

NB2: The ”Comm/Routing” tables are automatically retrievedonly with CONGI starting from version 3AL 78830AAACOtherwise the ”Comm/Routing” tables must be configurated manually using the Craft Terminal

Is the MIB storedin the Craft Terminal?

YESNO

MIB containing the correctconfiguration (NB1)

From O.S. send the saved

MIB containing the correctconfiguration (NB1)

From C.T. send the saved

(see NE management section)

”Activate” the sent MIBFrom O.S.

From C.T.

I1–1 ON I1–2 OFF

HW–PRESET THE EQUICO OR PQ2/EQC UNIT WITH:

I1–1 OFF I1–2 ON

Extract the EQUICOor PQ2/EQC unit

NB1

INSERT THE EQUICO OR PQ2/EQC UNIT IN THE SUBRACK

SUBSTITUTE THE OLD FLASH CARDWITH A NEW ONE

(Reset Data Base)

(Normal operating condition)

(Reset Data Base and upload Comm/Routing Tables)

INSERT THE EQUICO OR PQ2/EQC UNIT IN THE SUBRACK

HW–PRESET THE EQUICO OR PQ2/EQC UNIT WITH:

HW–PRESET THE EQUICO OR PQ2/EQC UNIT WITH:

Figure 33. FLASH CARD substitution

Page 567: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

71

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

6.2 Flash card substitution procedure for 1650SMC

N.B. In this paragraph for COMPACT ADM is generically intended one of the following unit:

– SYNTH1

– SYNTH1N

– SYNTH4

The 80 Mbytes FLASH card (housed on COMPACT ADM unit in slot 9) used up to rel. 2.0A requires tobe replaced with one having a higher size (256 Mbyte) in order to manage the new SDH+ATM/IP services.

N.B. Before to start with the FLASH card substitution ( flow–chart of Figure 34. on page 72 or flow–chart of Figure 35. on page 73 ) execute the following instruction:

a ) Save the MIB as explained in Section 3 (NE MANAGEMENT), Paragraph “Mib manage-ment” of this Manual.

b ) Create and install the enhanced software package (SDH+ATM/IP) as explained in “1320CT Basic Operator’s Handbook”.

The flow–charts of Figure 34. on page 72 illustrate the procedures to follow for the FLASH card substitu-tion with COMPACT ADM board EPS protected.

Warning: Substituting the FLASH CARD on COMPACT ADM unit (placedin slot 9) the traffic of the two SDH ports will be lost if not SNCP pro-tected.

Then it is suggested to replace in low traffic condition.

The flow–charts of Figure 35. on page 73 illustrate the procedures to follow for the FLASH card substitu-tion with COMPACT ADM board not EPS protected.

Warning: Substituting the FLASH CARD on COMPACT ADM (placed inslot 9) unit not EPS protected will cause traffic loss!

Then it is suggested to replace in low traffic condition.

Page 568: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

72

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

Download the NE relevant software packagewith SIBDL procedure

(see SIBDL section)

END

”Activate” the sent MIB

I1–1 OFF I1–2 OFF

INSERT AGAIN THECOMPACT ADM UNIT IN THE SUBRACK

NOTES:

NB2: The ”Comm/Routing” tables are automatically retrievedonly with CONGI starting from version 3AL 78830AAACOtherwise the ”Comm/Routing” tables must be configurated manually using the Craft Terminal

Is the MIB storedin the Craft Terminal?

YESNO

MIB containing the correctconfiguration (NB1)

From O.S. send the savedMIB containing the correct

configuration (NB1)

From C.T. send the saved

(see NE management section)

”Activate” the sent MIBFrom O.S. From C.T.

I1–1 ON I1–2 OFF

HW–PRESET THE COMPACT ADM UNIT WITH:

I1–1 OFF I1–2 ON

Extract the COMPACT ADM unit in slot 9

NB1

INSERT THE COMPACT ADM UNIT IN THE SUBRACK

SUBSTITUTE THE OLD FLASH CARDWITH A NEW ONE

EXTRACT AND HW PRESET THE COMPACT ADM UNIT WITH:

(Reset Data Base)

(Normal operating condition)

(Reset Data Base and upload Comm/Routing Tables)

BY CRAFT TERMINAL FORCE THE COMPACT ADM IN SLOT 10 TO BECAME ”ACTIVE”USING THE EPS RELEVANT EPS COMMAND

INSERT THE COMPACT ADM UNIT IN THE SUBRACK

EXTRACT AND HW PRESET THE COMPACT ADM UNIT WITH:

THE DECISION TO FORCE ”ACTIVE” THE COMPACT ADMUNIT IN SLOT 9 IS LEFT TO THE OPERATOR

Figure 34. FLASH CARD substitution (COMPACT ADM EPS protected)

Page 569: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

73

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

NOTES:

NB2: The ”Comm/Routing” tables are automatically retrievedonly with CONGI starting from version 3AL 78830AAACOtherwise the ”Comm/Routing” tables must be configurated manually using the Craft Terminal

NB1

WARNING: Substituting the FLASH CARD on the SYNTHN board not EPS protected will cause traffic loss!

Download the NE relevant software packagewith SIBDL procedure

(see SIBDL section)

END

”Activate” the sent MIB

I1–1 OFF I1–2 OFF

INSERT AGAIN THECOMPACT ADM UNIT IN THE SUBRACK

Is the MIB storedin the Craft Terminal?

YESNO

MIB containing the correctconfiguration (NB1)

From O.S. send the savedMIB containing the correct

configuration (NB1)

From C.T. send the saved

(see NE management section)

”Activate” the sent MIBFrom O.S. From C.T.

I1–1 ON I1–2 OFF

HW–PRESET THE COMPACT ADM UNIT WITH:

I1–1 OFF I1–2 ON

Extract the COMPACT ADM unit in slot 9

INSERT THE COMPACT ADM UNIT IN THE SUBRACK

SUBSTITUTE THE OLD FLASH CARDWITH A NEW ONE

EXTRACT AND HW PRESET THE COMPACT ADM UNIT WITH:

(Reset Data Base)

(Normal operating condition)

(Reset Data Base and upload Comm/Routing Tables)

INSERT THE COMPACT ADM UNIT IN THE SUBRACK

EXTRACT AND HW PRESET THE COMPACT ADM UNIT WITH:

Figure 35. FLASH CARD substitution (COMPACT ADM EPS not protected)

Page 570: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

74

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

6.3 Flash card substitution procedure for 1640FOX

The 80 Mbytes FLASH card (housed on COMPACT ADM unit in slot 2) used up to rel. 2.0A requires tobe replaced with one having a bigger size (256 Mbyte), in order to manage the new SDH+ATM/IP services.

N.B. Before starting with the FLASH card substitution (flow–chart of Figure 36. on page 75 ) executethe following instruction:

a ) Save the MIB as explained in Section 3 (NE MANAGEMENT), Paragraph “Mib manage-ment” of this Manual.

b ) Create and install the enhanced software package (SDH+ATM/IP) as explained in “1320CT Basic Operator’s Handbook”.

The flow–chart of Figure 36. on page 75 illustrates the procedures to follow for the FLASH card substitu-tion.

Warning: Substituting the FLASH CARD on COMPACT ADM unit willcause traffic loss!

Then it is suggested to replace it in low traffic condition.

Page 571: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

75

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

NOTES:NB1: the ”Comm/Routing” tables are automatically retrieved from the shelf of the equipment

WARNING: Substituting the FLASH CARD on the COMPACTADM will cause traffic loss

Download the NE relevant software packagewith SIBDL procedure

(see SIBDL section)

END

”Activate” the sent MIB

I1–1 OFF I1–2 OFF

INSERT AGAIN THECOMPACT ADM UNIT IN THE SUBRACK

Is the MIB storedin the Craft Terminal?

YESNO

MIB containing the correctconfiguration (NB1)

From O.S. send the savedMIB containing the correct

configuration (NB1)

From C.T. send the saved

(see NE management section)

”Activate” the sent MIBFrom O.S. From C.T.

I1–1 ON I1–2 OFF

HW–PRESET THE COMPACT ADM UNIT WITH:

I1–1 OFF I1–2 ON

Extract the COMPACT ADM unit

INSERT THE COMPACT ADM UNIT IN THE SUBRACK

SUBSTITUTE THE OLD FLASH CARDWITH A NEW ONE

EXTRACT AND HW PRESET THE COMPACT ADM UNIT WITH:

(Reset Data Base)

(Normal operating condition)

(Reset Data Base and upload Comm/Routing Tables)

INSERT THE COMPACT ADM UNIT IN THE SUBRACK

EXTRACT AND HW PRESET THE COMPACT ADM UNIT WITH:

Figure 36. FLASH CARD substitution (on COMPACT ADM unit)

Page 572: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

76

02

SC.4:NE MAINTENANCE

/3AL 91670 AA AA

76

76

END OF DOCUMENT

Page 573: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

1

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

METRO OMSN REL. 4.4/5.2A OPERATOR’S HDBK

TABLE OF CONTENTS

LIST OF FIGURES AND TABLES 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 INTRODUCTION 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Scope 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.1 Document scope 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.2 Target audience 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2 Terminology 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.1 Acronyms and abbreviations 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.2 Glossary of terms 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 DOWNLOAD WITH SIBDL 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 Purpose of the procedure 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1.1 SIBDL download procedure 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 CONFIGURATION FOR SIBDL 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 Purpose of the procedure 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.1.1 Remote Access Service configuration (only needed for Windows NT environment) 11. . 3.1.2 Serial Cable Modem configuration for Windows NT environment 11. . . . . . . . . . . . . . . . . . 3.1.3 Serial Cable Modem configuration for Windows 2000 environment 12. . . . . . . . . . . . . . . . .

ED DATE CHANGE NOTE APPRAISAL AUTHORITY ORIGINATOR

01 041119 C. FAVERO ITAVE P.GHELFI ITAVE

02 050414 ECR 23082 C. FAVERO ITAVE P.GHELFI ITAVE

METRO OMSNRel. 4.4/5.2AOPERATOR’S HANDBOOK

J.MIR – S. MAGGIO

J.MIR – S. MAGGIO

Page 574: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

2

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

LIST OF FIGURES AND TABLES

FIGURESFigure 1. SIBDL download procedure – step 1 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2. SIBDL download procedure – step 2 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3. SIBDL download procedure – step 3 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4. SIBDL download procedure – step 4 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 5. SIBDL download procedure – step 5 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 6. SIBDL download procedure – step 6 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 7. SIBDL download procedure – step 7 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 8. Serial Cable Modem configuration – step 1 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 9. Serial Cable Modem configuration – step 2 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 10. Serial Cable Modem configuration – step 3 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 11. Serial Cable Modem configuration – step 4 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 12. Serial Cable Modem configuration – step 5 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 575: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

3

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

1 INTRODUCTION

1.1 Scope

1.1.1 Document scope

The SIBDL Manual describes the SIBDL application, used to download the NE software via Q or Finterface.

The SIBDL (Standard Image Binary DownLoad) procedure contains the following operative descriptions:

– Download with SIBDL. The complete procedure is indicated. See Chapter 2 on page 5

– Configuration for SIBDL. Configurations to be performed for SIBDL operation are described. SeeChapter 3 on page 11.

1.1.2 Target audience

The SIBDL Manual is intended for all users.

The documents that should be read before starting this document are:

– 1320CT Basic Operator’s Handbook

1.2 Terminology

1.2.1 Acronyms and abbreviations

Refer to the Section Introduction manual.

1.2.2 Glossary of terms

Refer to the Section Introduction manual.

Page 576: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

4

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

Page 577: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

5

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

2 DOWNLOAD WITH SIBDL

2.1 Purpose of the procedure

This procedure describes how to download a NE software with the SIBDL (Standard Image BinaryDownLoad) program.

2.1.1 SIBDL download procedure

Download with SIBDL program is performed in the following phases:

• Turn on phase, when activating the NE.

• Maintenance phase, when substituting the EQUICO (1660SM rel. 4.x), PQ2EQC (1660SMRel.5.x) or SYNTH1N/SYNTH4 (1650SMC and 1640FOX) unit with a spare, and the spare onedoesn’t contain software.

ATTENTION:

Download with SIBDL program put the EQUICO, PQ2EQC or SYNTH1N/SYNTH4 unit out ofservice regarding to the supervision and control function, while the traffic is not lost.It must not be executed to download a spare unit that contains software; in this case use theDownload option of the EML–USM, presented in the previous section.

SIBDL tool permits to download the software towards the NE using the Q interface (Ethernet connection)or the F interface RS232 (serial line) of the NE .

When using the Q interface the time necessary to the operation is reduced to some minute (Q interfaceis available only on 1650SMC and 1660SM)

WARNING:

in Windows NT environment, it should have configured, before to use SIBDL:

• TCP/IP protocol, Protocol Service, TEL NET Accessory, defined by the NTAdministrator.

• RAS (Remote Access Service) and Serial Cable Modem presented at chapter 3 onpage 11.

in Windows 2000 environment, it should have configured, before to use SIBDL:

• TCP/IP protocol, Protocol Service, TEL NET Accessory, defined by theAdministrator.

• Serial Cable Modem refer to paragraph 3.1.3 on page 12.

N.B. RAS (Remote Access Service) is not necessary in Windows 2000 environment

Page 578: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

6

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

To download with SIBDL execute the following steps:

Note: the example in the following is referred to a 1660SM; the same rules can be applied to1640FOX and 1650SMC.

1 ) Connect the Craft Terminal with the NE:

• when download by means of Q interface, always connect both the F and Q interface(1650SMC and 1660SM).

• when download by means of F interface, connect only the F interface (1640FOX,1650SMC and 1660SM).

2 ) Start SIBDL, selecting Start > Program>Alcatel>SIBDL”version”>SIBDL

3 ) In the screen which appears (see Figure 1. ) with the command menu, select “automatic mode”command typing 8 and then ENTER.

Figure 1. SIBDL download procedure – step 1

4 ) In the field “source file” at the bottom write the path name of the NE descriptor file (seeFigure 2. ).

The path name has typically the following format (see the example in the figure):

<directory>/<NE name and release number>/<file descriptor>

Note:In current release it is possible to download two types of file descriptor according to the following rules:

1) Create the NE software package as explained in the paragraph “NE Softwarepackage installation procedure” SC.3: NE MANAGEMENT of this Manual.

2) If the software to download manage only the SDH functionality, select the file descriptorin the directory 1660SM.(example: /ALCATEL/Q3CT_Pv1.3.05/FTservices/data/1660SM/2.1b.09/1660.dsc)

3) If the software to download manage the SDH + ATM/IP functionality, select the filedescriptor in the directory 1660SME(example: /ALCATEL/Q3CT_Pv1.3.05/FTservices/data/1660SME/2.1b.09/1660.dsc)

Page 579: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

7

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

C:\ALCATEL\Q3CT_Pv1.3.05/FTservices/data/1660SME/2.1b.09/1660.dsc

Figure 2. SIBDL download procedure – step 2

5 ) Press ENTER

6 ) This step (see Figure 3. ) ask for the “IP Address” insertion.

In the field “NE_IP_address[ PPP TEL NET]” at the bottom:

– with F interface: write PPP and press ENTER

– with Q interface (only1650SMC and 1660SM):

• first possibility: write TELNET and press ENTER

In next step which appears write the IP Address of the Craft Terminal

• second possibility: write the IP Address of the NE and press ENTER

ervices/data/1660SME/2.1b.09/1660.dsc

Figure 3. SIBDL download procedure – step 3

7 ) This step ( see Figure 4. ) ask if the flash card must be formatted.

Type “y” to format the flash card; as result of this action the program ask for a confirmation (seeFigure 5. )

Page 580: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

8

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

ervices/data/1660SME/2.1b.09/1660.dsc

Figure 4. SIBDL download procedure – step 4

ervices/data/1660SME/2.1b.09/1660.dsc

Figure 5. SIBDL download procedure – step 5

8 ) Type “y” . The screen shows the automatic download evolution with a final message indicatingthe completed download (see Figure 6. ).On the contrary repeat the procedure.

Page 581: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

9

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

Figure 6. SIBDL download procedure – step 6

9 ) Press ENTER.

10 ) In the presented screen type 4 (see Figure 7. ) and ENTER.

Figure 7. SIBDL download procedure – step 7

11 ) Extract and re–insert the EQUICO (for 1660SM Rel. 4.3), PQ2EQC (fro 1660SM Rel. 5.1) orSYNTH1N/SYNTH4 (1650SMC or 1640FOX) unit to complete the operation.

12 ) Extract and re–insert again the EQUICO (for 1660SM Rel. 4.3), PQ2EQC (fro 1660SM Rel. 5.1)or SYNTH1N/SYNTH4 (1650SMC or 1640FOX) unit to complete the operation.

13 ) Run the 1320CT application, execute Start supervision and NE login

Page 582: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

10

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

14 ) From Craft Terminal ( EML–USM view) execute the normal download procedure:

N.B. Check that no RUTM alarm is present in the slot reserved to the main MATRIXN for1660SM Rel. 4.3 or SYNTH1N for 1650SMC.If RUTM alarm is present means that the board type inserted in the subrack (typicallyMATRIXN or SYNTH1N in this release) and the board type software configurated(typically MATRIX or SYNTH1) is not the same; under this condition the user mustchange the board type with the Equipment–>Set menu.

– Select Init download from Download menu– Select the SW package to Download and click on OK button

In this condition the download is executed immediately.– Select Unit info from Download menu– Select the Software Package loaded as explained above and activate it– Press OK to complete the operation

In this condition the download is executed immediately.

Page 583: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

11

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

3 CONFIGURATION FOR SIBDL

3.1 Purpose of the procedure

This chapter describes the configurations to be performed for SIBDL operation.

3.1.1 Remote Access Service configuration (only needed for Windows NT environment)

To install a new modem, the user should have administrator privileges and need the installation CD–ROMof Windows NT, then execute:

– Double click on ”My computer” icon on the PC desktop and double click on ”Control panel” icon;– double click on ”Network” icon;– select the folder ”Services” in the ”Network” window and push the button ”Add”: start the ”Select

Network Service” window;– select Remote Access Service (RAS) in the dialog box;– follow the instructions.

3.1.2 Serial Cable Modem configuration for Windows NT environment

To install a new modem, the user should have administrator privileges, then execute:

– Double click on ”My computer” icon on the PC desktop and double click on ”Control panel” icon;

– double click on ”Network” icon;select the folder ”Services” in the ”Network” window;

– select ”Remote Access Service” and push button ”Properties...”;

– push the button ”add” in ”Remote Access Setup” window;

– push the button ”Install Modem” in ”Add RAS Device” window: start the ”Install New Modem” window;

– put a tick against ”Don’t detect my modem; I will select him from a list” and push the ”Next > ” button;

– push the button ”Have disk...”: start the window Install from disk;

– push the button ”Browse...;search the folder where SIBDL is installed (Alcatel / SIBDL “version” / SIBDL /)and select the file”mdmalca.inf”, after push the button ”Open”;

– push the button ”OK” in window ”Install from disk”;select the modem named ”Serial cable” in the dialog box of window ”Install New Modem” and pushthe button ”Next >”;put a tick against ”Selected ports” and select only one port (the port must be available, i.e. not usedby another RAS modem) and push the button ”Next >”;

– follow the instructions;

– push the button ”OK” in ”Add RAS Device” window;

– push the button ”Continue” in ”Remote Access Setup” window;

– push the button ”OK” in ”Network” window;

Page 584: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

12

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

3.1.3 Serial Cable Modem configuration for Windows 2000 environment

To install a new modem, you should have administrator privileges;

– Double click on ”My computer” icon on your PC desktop and double click on ”Control panel” icon;

– Double click on ”Phone and Modem Options” icon and select the ”Modems” folder;

– Push the button ”Add”: ”Add/Remove Hardware Wizard: Install New Modem” window will appear;

– Put a tick against ”Don’t detect my modem; I will select it from a list” and push the button ”Next > ”;

Figure 8. Serial Cable Modem configuration – step 1

– Push the button ”Have disk...”: the window ”Install from disk” will appear;

– Push the button ”Browse...;

– Search the folder where SIBDL is installed and select the file ”mdmalca.inf”, after push the button”Open”;

– Push the button ”OK” on the ”Install from disk” window;

– Select the modem named ”Serial cable” into dialog box from ”Install New Modem” window and pushthe button ”Next >”;

Page 585: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

13

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

Figure 9. Serial Cable Modem configuration – step 2

Page 586: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

14

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

– Put a tick against ”Selected ports” and select only one port (the serial port must be available, i.e. notused by another RAS modem) and push the button ”Next >”;

Figure 10. Serial Cable Modem configuration – step 3

– The window ”Digital Signature Not found” will appear: push the button ”Yes”, and after the button”Finish” to end modem installation;

Figure 11. Serial Cable Modem configuration – step 4

Page 587: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

15

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

– At the end, the ”Phone and Modem Options” window will display the installed modem

Figure 12. Serial Cable Modem configuration – step 5

Page 588: 1660 S M  Oper  R4

All

right

s re

serv

ed. P

assi

ng o

n an

d co

pyin

g of

this

docu

men

t, us

e an

d co

mm

unic

atio

n of

its

cont

ents

not p

erm

itted

with

out w

ritte

n au

thor

izat

ion

from

Alc

atel

.

ED

1AA

000

14 0

004

(900

7) A

4 –

ALI

CE

04.

10

16

02

SC.5: SIBDL

/3AL 91670 AA AA

16

16

END OF DOCUMENT