Upload
buitu
View
226
Download
1
Embed Size (px)
Citation preview
Add 6P location insideexisting MiddleAtlantic Cabinet.Terminate to existingBelden patch panel incabinet. Coordinatewith PHSD prior toinstallation.
2'6
" SO
FF
IT
2'6
" SO
FF
IT
2' S
OF
FIT
2' S
OF
FIT
CEILING HT 16'7"
10'7
" HT
10'7" HT
9' CLNG
10' CLNG
11' C
LNG
8'6" SFFT
9'6" SFFT
10'6
" SFFT
8' SFFT
9'1
1" C
LN
G
TR-02
TR-01
102
101
103
104
105
106 107
108109
110
201202
203
204
205 206
207
208
209
210
301
302
303
304 305
306
307
308
309
310
LMC
CAFE
CUSTODIAL
OFFICE
NURSE
PNPLAP
ST
AG
E
GYM
CONF
112402 401
AdvClb
STO
312
111
311
STO
FD
FD
FD
FS
REF.
2-FS1.1
3
FD
FD
FS
FD
FD
10'6
" SFFT
8' SFFT
G000
G4
G000
G16
G000
G10 NEW DESCO FLOORING AT CAFE AND ALL RELATED LABOR, MATERIALS, EQUIPMENT AND PREP WORK TO INSTALL. (2165 SF +/-)
DESCO: GRANITE SERIES COLOR: TBD
1
BOTH SIDES-1/4" GAP WITH SEALANT
08 11 13.A03
3/8"
07 92 00.A01
BOTH SIDES
NEW LINTEL W/(2) #4 BARS HORIZONTAL GROUTED SOLID
SAWCUT EXISTING MAS BLOCK WALL
7'-4 3
/8" ±
TO
FIN
FLR
SAWCUT & REMOVE CLEANLY WITH NO OVER-CUTS AT CORNERS
#4 REINFORCING BARS
DRILL 2" MAX DIA HOLES (1 EA END) TO GROUT BOND BEAM
SLOT BOTTOM OF BOND BEAM BLOCK FOR VERTICAL BAR
08 11 13.A03
07 92 00.A01
04 20 00.A10
3/8"
SAWCUT EXISTING MAS BLOCK WALL
GROUT NEW CELLS SOLID
ROUGH OPENING WIDTH + 1 '- 4"
(2) #4 BARS VERTICAL EACH JAMB
SAWCUT EXISTING MAS BLOCK WALL
NEW HALF BULLNOSEEA JAMB
3/8"
ROUGH OPENING WIDTH
08 11 13.A0308 11 13.A03
07 92 00.A0107 92 00.A01BOTH SIDES
04 20 00.A0104 20 00.A01
PER SCHED
PER
SC
HED
A SC WOOD (08 14 16.a01)
2" PER SCHED 2"
PER
SC
HED
4"
08 11 13.A03
INFILL EXISTING DOORS, TOOTH IN NEW BLOCK. PAINT FINISH
(EA SIDE) TO BE PRIVIDED BY ARCHITECT
3B
3B
EXISTING DOORTO REMAIN
EXISTING DOORTO REMAIN
1
1
9' -
0"
TR-01
3B
10' - 0"
DEMO EXISTINGCOUNTER
ALIGN
DEMO COUNTERAT JOINT
TR-02
3B
3B
2
2
CHECK
SET
1 2 3 4 5 86 7 9 10
1 2 3 4 5 86 7 9 10
1311 12 14 15 16 17
1311 12 14 15
DRAWN BY:
DATE:
REVISIONS:
16 17
CHECKED BY:
The Professional Architects seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plan, drawings, or documents not exhibiting this seal.
A
B
C
D
E
F
G
H
N
J
K
L
M
Q
P
R
A
B
C
D
E
G
H
N
J
K
L
M
Q
P
R
F
Please consider the environment before printing this.
Missouri State Certificate of Authority Architecture # 0000161Structure # 2006031333
Hollis + Miller Architects
JOB NO:
Smith and BoucherMEP EngineersState Certificate of Authority #EGC-00017825501 Valley Parkway, Suite 200 Olathe, Kansas 66061 913.345.2127 phone
2/1
/2
01
8 4
:36
:27
PM
Project Number
LT
Pa
rk H
ill
Sc
ho
ol
Dis
tric
t
Pra
irie
Po
int
Ele
me
nta
ry
G000
COVER SHEET
81
01
NW
Be
lvid
ere
Pa
rkw
ay
Ka
nsa
s C
ity,
MO
64
15
2
2018
MP
ISS
UE F
OR
BID
Prairie Point ElementaryPark Hill School District
8101 NW Belvidere ParkwayKansas City, MO 64152
ISSUE FOR BID
GENERAL
G000 COVER SHEET
INDEX OF DRAWINGS
REMOVE EXISTING CARPET AND BASE INCLUDING ADHESIVE.
DEMOLITION NOTES
FLOORS & BASE
WALLS
1
1
2 REMOVE EXISTING CASEWORK WITH ASSOCIATED COUNTERTOPS & ALL RELATED PLUMBING FIXTURES. RE: PLUMBING DEMO.
REMOVE EXISTING METAL FRAME, DOOR & ALL RELATED HARDWARE.
Scale
1/32" = 1'-0"A4
Overall - Level 1
Scale
1 1/2" = 1'-0"D16 HM Jamb @ CMU
Scale
1 1/2" = 1'-0"A12
HM Head Retrofit @ CMU Wall (Interior Only)
Scale
1 1/2" = 1'-0"D12
HM Jamb Retrofit @ CMUScale
1/4" = 1'-0"D10 Door Types
Scale
1/4" = 1'-0"A10 Frame Types
Scale
1/4" = 1'-0"G4
Unmarked Rm Scale
1/4" = 1'-0"G16 TR-01Scale
1/4" = 1'-0"G10
TR-02
DESIGN TEAM
ARCHITECTURAL DESIGN:Hollis + Miller Architects1828 Walnut Street Ste 922Kansas City, MO 64108CONTACT: Michael PatrickPHONE: (816) 442-7700FAX: (816) 599-2545
DOOR Frame All DETAILS on A521 UNO
Fire Rating RemarksNumber Size Type Type Material Head Strike Hinge
TR-01 3'-0" x 7'-0" x 1 3/4" A 1 HM --
TR-02 3'-0" x 7'-0" x 1 3/4" A 1 HM --
WALL TYPES
3B - 8" CMU - TO DECK
VICINITY MAP
CONSTRUCTION MANAGERS:Universal Construction11200 W. 79th StreetLenexa, KS 66214CONTACT: Archie SmithPHONE: 913.342.1150
MECH/ELECT ENGINEERS:Smith & Boucher25501 Valley Parkway, Suite 200Olathe, KS 66061CONTACT: Kent McCoshPHONE: 913.345.2127
# Description Date
A
DC
B
AREAS
Project Site
INDEX OF DRAWINGS SITE
Address
Vicinity Map
Kansas City MO, 64152
8101 NW Belvidere Parkway
Prairie Point Elementary
Prairie Point Elementary School Telecommunications Package
GeneralPP-G000 Cover Sheet
TelecommunicationsPP-T000 SchedulesPP-T001 Telecommunications Station Plan - Area APP-T002 Telecommunications Station Plan - Area BPP-T003 Telecommunications Station Plan - Area CPP-T004 Telecommunications Station Plan - Area DPP-TR01 Telecommunications RoomsPP-TB01 Telecommunications Backbone PlanPP-TC01 Telecommunications Cable Tray Plan
Special Outlet Schedule - Wall
Typical Data Work Area Outlet (ref. spec.) with specified quantity of Data Horizontal Cables (Copper) (Cat6a) (ref.spec.) from nearest TR.
Typical Wall Phone Outlet (ref. spec.) with (1) one Data Horizontal Cable (Copper) (Cat6a) (ref. spec.) from nearest TR.
Indicates above counter.
Typical Audio-Visual Outlet (ref. spec.) with (2) two of Data Horizontal Cables (Copper) (Cat6a) (ref. spec.) from nearestTR and Audio Visual Cable (ref.spec) to ceiling projector.
Indicates above counter.
Special Outlet Schedule - Ceiling
Typical In-Ceiling Data Outlet (ref. spec.) with (1) one Data Horizontal Cable (Copper) (Cat6a) (ref. spec.) from nearest TR.
Typical In-Ceiling Data Outlet (ref. spec.) with (2) two Data Horizontal Cables (Copper) (Cat6a) (ref. spec.) from nearest
TR.
Typical In-Ceiling Data Outlet (ref. spec.) with specified quantity of Data Horizontal Cables (Copper) (Cat6a) (ref. spec.)
from nearest TR.
Typical In-Ceiling Data Outlet (ref. spec.) with (1) one Data Horizontal Cable (Copper) (Cat6a) (ref. spec.) from nearest TR.
Typical In-Ceiling Data Outlet (ref. spec.) with (1) one Data Horizontal Cable (Copper) (Cat6a) (ref. spec.) from nearest TR.
Typical Television Outlet (ref. spec.) with (1) one Data Horizontal Cables (Copper) (Cat6a) (ref. spec.) and (1) one Coax
Cable from nearest TR.
Typical In-Ceiling Data Outlet (ref. spec.) with (1) one Data Horizontal Cable (Copper) (Cat6a) (ref. spec.) from nearest TR.
Typical In-Ceiling Data Outlet (ref. spec.) with (1) one Data Horizontal Cable (Copper) (Cat6a) (ref. spec.) from nearest TR.
Typical In-Ceiling Data Outlet (ref. spec.) with (1) one Data Horizontal Cable (Copper) (Cat6a) (ref. spec.) from nearest TR.
Special Outlet Schedule - Floor
Typical Audio-Visual Floor Outlet (ref. spec.) with (2) two of Data Horizontal Cables (Copper) (Cat6a) (ref. spec.) from
nearest TR and Audio Visual Cable (ref.spec) to ceiling projector or television.
Special Outlet Schedule - Other
Typical Alarm Outlet (ref. spec.) with specified quantity of Data Horizontal Cable (Copper) (Cat6a) (ref. spec.) from nearest
TR.
Typical HVAC Outlet (ref. spec.) with specified quantity of Data Horizontal Cable (Copper) (Cat6a) (ref. spec.) from nearest
TR.
Typical Intercom Outlet (ref. spec.) with specified quantity of Data Horizontal Cable (Copper) (Cat6a) (ref. spec.) from
nearest TR.
Typical Door Access Control Location (ref. spec.) with (1) one Door Control Cable (Copper) (ref. spec.) from nearest TR
(excluding zone enclosures).
Symbols
Excluded Area
Ceiling Demolition
Outdoor Area
Area not included in current section - refer to section map and corresponding sheet
A
DC
B
A
DC
B
A
DC
B
A
DC
B
TR-01 TR-02