06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

Embed Size (px)

Citation preview

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    1/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    M2000 User Guidefor Optimization Engineers

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    2/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    Reference for use of M2000The direction for use of M2000

    Overview of M2000

    How to register object

    How to register the counter

    How to maintain the counter

    How to query the counter

    How to apply real time (short periods) counter How to operate custom counter

    How to import and export the template of counter

    How to manage the threshold of counter

    FAQ problems of M2000

    How to do if we cant query the counter data

    How many network elements can M2000 manage

    Answers to the common problems

    Direction of M2000 versions new supported function

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    3/52

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    4/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    Overview of M2000M2000, using two kinds of working mode, including client and server terminals. The software of

    M2000 is made up of client, server and network element adapter, which are independent from

    each other. Client software runs on client terminal, while the server and network element adaptersoftware run on the server terminal.

    How do M2000 configure the net? Especially for BSC6000? First, M2000 sends the order, all theconfiguration data is written into an XML file. Secondary, uploaded to M2000 by FTP, then the

    configured server will fetch the network elements configuration data according to MIT trees

    related interfaces of BSC6000. So, without making any operation of data configurations in M2000

    we can see all the messages of cells and carrier frequency managed by BSC6000.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    5/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    Overview of M2000

    The functions offered by M2000 are not only the management of performance

    counter, but also the centralized managements of topology, configuration, fault,software and safety.

    Main functions offered by performance counter management:

    Management of performance counter and objects

    Real time measurement functions

    Real time monitoring

    Management of performance data

    Performance alarms

    Custom counter

    After the connecting between M2000 and BSC6000, BSC will upload a default taskfile of a network element to M2000 server. M2000 will analyze and verify the format

    and content of this task file, and then create a new task file according to the

    measured counter management, finally descend to network element.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    6/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to register object

    Object measurement

    To define the measurement object. Measurement object can be subrack or cabinet for physical concept or cells for logical concept.

    Measurement object and measurement counter corresponding to each

    other. Different measurement object has different measurement

    counter, a measurement counter can only be applied for one kind of

    measurement object. The counter is divided into several measurementfunction integration, one measurement function integration is also

    divided into several measurement units which are corresponding to

    one kind of measurement object.

    While adding network elements, such as new sites, M2000 might not

    update object list immediately, we can synchronize the configurationsmanually.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    7/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to register object

    In the M2000 network topology interface, select the network element graph needed to

    be maintained, open the right button menu and select Synchronize CM data; thesynchronization progress will be displayed on the network element graph.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    8/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to register object

    Most of the BSC6000 counteres are collected by network element itself according to

    hours, and a result file is to be created. However, whether these counteres will beconverted into M2000 server database and queried, some settings have to be done.

    (register or not, KPI counteres will be saved and available to be queried).

    The operations related to traffic statistic of M2000 are included in Performance

    menu

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    9/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to register object

    Open performance menu, select Object Setting, then start registering object in the

    pop- up interface. Like the graph below, unfold the cell object, under of which are thenetwork element (BSC6000),

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    10/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to register Counter

    According to the source of counter, we can divide them into two parts: system

    counter and custom counter. System counter could also be divided into two parts:Key counter and Extension Performance counter.

    The counter defined in M2000 by user is custom counter.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    11/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to register counter

    Key performance counter

    Important counter of network element, measurement state by default, usercan not cancel the measurement.

    Extension performance counter

    Non measurement report are not available until we register it, after registering,

    it can start, user could cancel the measurement.

    Custom counter

    Custom counter is a new measurement counter, which is created by portfolio

    operation of original counter.

    Custom counter is made up of value, constant and integral operators. All system

    counteres involved in a certain custom counter must correspond to a same object

    type. The formula defined in custom counter can be nested.

    The length of formula must be less than 255 bytes.

    User can create, modify or delete custom counter, but cant deliver measurement

    directly.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    12/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to register counter

    Select Counter Setting , register the counter on pop -up interface:

    such as the graph below, only the Default Counter (KPI counter) are automaticallyselected when commissioning site, other Extended Counter has to be selected

    manually. Finish selecting, click Apply or OK.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    13/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to register counter

    Architecture of performance measurement counter

    The system has a large amount of performance measurement counter. In

    order to use and manage conveniently, this counter must be managed

    layer by layer.

    Layer 1, functional set (measurement set), includes several functional sub

    set related to certain aspect of system function.

    Layer 2, functional sub set (measurement unit), includes several

    measurement counter related to certain system function.

    Layer 3, measurement counter.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    14/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to register counter

    In counter registering interface of M2000, structure of the counter distributes

    according to measurement object/business process, level one catalogue distributes

    by object, what RNO pays attention to are:

    BSC Measurement

    Call Measurement

    CHAN Measurement

    MR Measurement

    PAGE Measurement

    Call Measurement is the most important, which is separated into several business

    process, including access, assignment, handover, call drop and so on.

    MR Measurement is traffic statistic of measurement report, it includes traffic volume,

    interference band, up-down link balance, etc.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    15/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to maintain counter

    counter maintenance function includes several aspects:

    Synchronize the measurement result of a certain time segment Subscribe measurement, dynamically examine the result reporting instance

    Query reliability instance of measurement result in a certain time segment

    Query the loss instance of measurement result in a certain time segment

    suspend and resume measurement

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    16/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to maintain counter

    The interface of maintenance counter (the graph below), the function buttons referred

    before are at the bottom of the interface:

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    17/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to maintain counter

    How to maintain counter :synchronize

    Synchronize network element data manually, so that the lost measurement datacan be recovered from the network element.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    18/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to maintain counter

    How to maintain counter: subscribe

    After subscribing, newly reported performance measurement result will bedisplayed in the interface automatically.

    A limit of five subscribedmeasurement instances in everyinterface

    Cancel the subscribeof current Tab andclose it

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    19/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to maintain counter

    How to maintain counter: miss the queried result

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    20/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to maintain counter

    How to maintain counter: query reliability

    While network element reporting measurement result, the reliability informationwill be included, so as to describe whether these data is reliable. It shows the

    ratio of the reliable result in the whole measurement result.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    21/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    Select query result in performance main menu

    Query measurement result according to different conditions (counter/object/timesegment).

    Save the set query condition as a template, this template can also be copied and

    pasted.

    The measurement result can be displayed in the form of table, linearity graph

    and histogram.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    22/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    counter query interface:

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    23/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    Direction of tree structure

    In the counter query interface, every login user has his own directory. Unfold thedirectory, there is a query template which is belongs to the login user.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    24/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    ObjectSetting

    CounterSetting

    Direction of counter query: counter query is to query the database under conditions of object,counter and time, so these three aspect must be selected in the counter query interface.

    Get Result

    OthersSetting

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    25/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    In order to create a query, we have to right click on the level 1 tree directory, and

    select New Query.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    26/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    counter selection:

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    27/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    Time selection:

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    28/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    Every new query, there is a save template button, we can save the template, so that

    if we have to query the same counter next time, it can be easily done by clicking the

    template.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    29/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    Query result (in the form of table chart) , most common form.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    30/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    Query result in the form of linearity chart

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    31/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to query counter

    Query result in the form of histogram

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    32/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to apply real time (short periods) counter

    The period of real time counter measurement is less than 30 minutes, commonly 5min or 15min,for the purpose of trouble shooting (paging or handover) in a short time. Mostly we dont use it. In

    order to prevent M2000 from data processing overload.

    Maintenance and queryoperation of real timecounter is the same asnormal counter, but thefunction entrance

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    33/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to operate custom counter

    Direction of custom counter operation:

    Custom counter is made up of value, constant and operator.

    After all the original counter come into measurement status, the user custom counter

    will come into measurement status.

    All system counteres involved in a certain custom counter must correspond to a same

    object type. So as to say: one object type can span function sub set.

    User can create, modify or delete custom counter.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    34/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to operate custom counter

    Select Customer Counter Management in the performance menu, M2000 will switch

    to custom counter operation interface:

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    35/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to operate custom counter

    See the graph below:

    Select thequery unitwhere newcounter issaved Existing defined

    custom counter

    After user login, select thecustom counter, and the modifyor delete operation will beavailable

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    36/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to operate custom counter

    Tips of custom counter usage

    Naming of custom counter must distinguish obviously from the system selfcounter.

    Export the custom counter to xml file, and import in other M2000 server.

    We cant edit the custom counteres created by other user, but we can copy them

    in counter browse interface and make use of them convenient.

    Custom counter support nested counter , the custom counter set by user canbe used in other counter formula.

    When querying custom counter, it must be calculated by M2000. Unlike the

    system counter which is calculated at the time while reporting archive. So custom

    counter need more query time (V2R6 and its higher version, custom counter will

    be calculate at the archive time).

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    37/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to operate custom counter

    In the new custom counter interface, formula can be copied and pasted directly in formula

    editing area.

    Formulaediting area

    Or i gi n

    al c

    o un t er

    an

    d

    ex i s

    t i n g c o un t er

    s el e

    c t i n g ar

    e a

    O p er

    a t or

    an

    d c on

    s t an

    t

    s el e

    c t i n g ar e

    a

    How to import and export the template of

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    38/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to import and export the template ofcounter

    Export of user created custom counter

    Step1 selectcounter

    Step2:click export

    How to import and export the template of

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    39/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to import and export the template ofcounter

    Export of user created custom counterStep3 save as .XML

    How to import and export the template of

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    40/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to import and export the template ofcounter

    Import of user created custom counter Click import, open saved .XML

    h h h ld f

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    41/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to manage the threshold of counter

    Threshold management

    For the purpose of KPI monitor, we can set a threshold value to manage. M2000 will

    use the form of alarm to inform user that the counter has been changed based on the

    pre set threshold values. However, the counter reporting can only support minimum

    15 minutes granularity. The subsequence version can support the counter reporting

    for less than 15 minutes also.

    Threshold management includes: Set threshold according to a certain network element or measurement unit

    Two threshold direction: ascent and descent

    Four threshold alarm levels: warning, minor, major, critical.

    Hysteresis can be set separately.

    Threshold can be created, modified, deleted, or suspended.

    H h h h ld f

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    42/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to manage the threshold of counter

    Threshold management: performance threshold measurement interface

    H h h h ld f

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    43/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to manage the threshold of counter

    Threshold management: add threshold

    H h h h ld f

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    44/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to manage the threshold of counter

    Threshold management: modify threshold

    H t th th h ld f t

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    45/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to manage the threshold of counter

    Threshold management: suspend threshold

    FAQ bl f M2000

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    46/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    FAQ problem of M2000

    How many network elements can M2000 manage

    How to do if we cant query the counter data

    Answers to the common problems

    direction of M2000 versions new supported function

    H t k l t M2000

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    47/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How many network elements can M2000 manage

    M2000 version Database platform Hardware platform Number of networkelement

    R3C01B063 &earlierversion

    Solaris8+Sybase12

    Sun Fire V890 Server 8CPU No more than 90

    Sun Fire E4900 Server 8CPU No more than 120

    R3C01B065 &subsequenceversion

    Solaris10+Sybase15

    Sun Fire V890 Server 8CPU No more than 120

    Sun Fire E4900 Server 8CPU No more than 160

    V2R5 predictive

    specSolaris10+Sybase15

    Sun Fire V890 Server 8CPU No more than 150

    Sun Fire E4900 Server 8CPU No more than 200

    Ability of network element management ( common setting )

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    48/52

    H t d if t q th t d t

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    49/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    How to do if we cant query the counter data

    Failing to archive is the main reason, several scenes are described below:

    The size of original network element reporting file in M2000 server is 0K, which

    results in failing to read the real data.

    Due to bad transmission condition between M2000 and BSC, error files will be

    created. We need to delete these files before archive. M2000 version

    V2R3C01B065SP04 and its subsequence version can solve this problem.

    High amount of data query leads to deadlock of database Cleaning the database and restart M2000 server are needed, for BSC6000, we

    must strictly control measurement object activation data related to Neighbor cell

    measurement.

    Register 15 minutes traffic statistic, leads to slow data archive:

    Close short period traffic statistic, or it would cause large amount of data needsto archive on the hour, it would also delay the normal period traffic statistic to

    archive.

    Answers to the common problems

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    50/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    Answers to the common problems

    Common problems

    After query result files saved as .EXCEL, number format is saved as text format,

    which leads to failure to edit the data directly

    R3C01B065SP03 and its earlier version, we need to transfer the data or save it

    as .CSV format.

    R3C01B065SP04 version, number can be saved directly.

    counter query/register interface, how to do if all counteres needed to be selected?

    Drag the scroll bar to the bottom, and click all item, thats ok.

    Some appraisal counteres of customer need to be calculated by custom formula,

    but the query is very slow, how to do?Suggest not use custom counter in M2000, export the original counter, write

    macro/formula ourselves to improve the speed.

    Direction of M2000 versions new supported function

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    51/52

    All Rights Reserved 2006, Huawei Technologies CO., LTD.

    Direction of M2000 versions new supported function

    Evolution of M2000 version

    CME imported

    New version is not only enhanced on performance statistic, but also imports CME module on datasetting, which can support both import and export EXCEL format of all network optimizing parameters.

    The adding of CME function can make user deal with daily parameter modifying and operation related

    to network optimizing efficiently. Besides, between different network elements, some matchingfunctions can be implemented automatically: for example, automatically cell data modifying after sitesswap to other BSC.

    MML importedImport of MML can improve the efficiency of daily data modifying and querying.

    Man-machine interface optimized

    Function persistence optimizing: real time monitor of counter, cooperate with network

    element to complete less granularity counter monitor.

    Query report: many sheets can be set in one report, and it can include differentmeasurement object/counter; at the same time, we can set TopN query or conditional display.

  • 8/3/2019 06 M2000 User Guide for Optimization Engineers-20071207-A-1.0

    52/52

    Technology changes.Communication lasts.