FAE: Chad Tseng
Telecom Power New Smart
CSU Presentation
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
2/26
1Telecom Power System
Telecommunication Power System
AC Input
Generator
U.P.S
A C Di s t r i b u t i on
Uni t
Rectifier # 1
Control SupervisoryUnit (CSU)
L OAD
( S wi t c h
,AD S L
E
.T . C . )
O u t p u t D
C Di s t r i b u t i on
Uni t
LVDS
Rectifier # 3
Rectifier # 2
Rectifier # N
Battery
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
3/26
New Smart CSU System Function Block
NSCSU
RS-485
RS-232
Web Server SMNP Server
Rectifiers
SMR Shelf
Rectifiers
Max: 4 PCsID, DCI,Alarm,S/N
RS-485
Rectifiers
SMR Shelf
Rectifiers
Max: 4 PCsID, DCI,Alarm,S/N
Rectifiers
SMR Shelf
Rectifiers
Max: 4 PCsID, DCI,Alarm,S/N
R S - 4 8 5
I.D.Add ress
R S - 4 8 5
I.D.Add ress
R S - 4 8 5
I.D.Add ress
IB U SIB U S
PDU DetectionI/O function
Anal og S ignal
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
4/26
PDU (Several Configurations)
Rectifier ESR-48/56A
Battery & Base
New Smart CSU (Main Board))
New Smart CSU (Relay Board))
19Rectifier Shelf (SB-05N/HG A )
160W Heat-exchange
CCU (ClimateControl Unit )
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
5/26
RS-485
New Smart CSU: DPS 2700 Series
Configuration,Supervision Terminal Interface
Web/SNMP Card
Ethernet
Configuration,Supervision(web browser)
54Vdc/50AWith SMR
AnalogSignal Detection
LCD Display
RS-485 X 3With SMR
RS-485 WithSMR
AnalogI.D address
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
6/26
New Smart Control andSupervisory Unit
To LCD display
Down S/W Program and RS232
Board Main Power
Main Board
Display 128 x 64
To RelayOutput
Terminal
Connector Board
Expand Board
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
7/26
New Smart Control and
Supervisory Unit
Features: System Input AC Voltage Detection 3 Phases System Output DC Voltage Detection LCD Display Dots 128 x 64 type (Option)
Four Switch Button for Display setting System Battery Current Detection X 2 system Load Current Detection X 1 Battery Fuse Detect X 4
Seven LED display On board
Features:Breaker(Plug-in) Detect 2 Rails Load Fuse/Breaker Detect X 13(Series Detection)
(Including GMT Fuse Detect X 1)
LVDS Control X 2 Environment Temp. X1 and Batt. Temp.X 2 8 Relay Alarm output (From C type ) 3 switch function for setting (On Board)
External Buzzer Alarm X 1 (Option )
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
8/26
Transformer full waves
Acv Detect - LM358
CPU M9S12E128MFU
Date Bus & AddressBusRelay enable &CommunicationCrystal =11.0592Flash ROM 32K
EEPROM 24C16
Save all Parameters
Relay Out - 8 N.C.
Major & Minor &ACDN
HV & TA Fail & RFA &LVDS& EQU
Power - 2843
Input 20Vdc-60Vdc+5V , S5V , R5V,
A15V,B 15V
V+
V-
Differential Amplify
Batt Current Detect - OP07
Differential Amplify
DCV Detect OP07
Buffer Translation
Temp Detect LM258
DigitalI/O
Photo isolate detect
Load Fuse Detect - TLP621
Photo isolate detect
Batt Fuse Detect TPL621
Rail Function Board
Breaker Detect - LM358
New Smart CSU Function Block
Clock DS1306N
Real Time Clock withBattery
LED Out - 8 LED
Major & Minor &ACDN
HV & TA Fail & RFA &LVDS& EQU
74541/74573
Digital
I/O
74541/74573
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
9/26
User friendly operating interfaceLarge 128 x 64 Dot LCD Display
Entry of alarm and system parameters from keypadHigh reliable RS-485 communicationMulit- Language (Sim chinese Tri Chinese;English)Easy system configuration and expansion
Featured functionsStand-alone operationProvisioning AlertGreen Energy ManagementTemperature & Voltage compensationBattery capacity and load testGenerator Control
Different possibilities for remote monitoringInternet/Local Access
New Smart CSU Features and Benefits
User Interface
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
10/26
Main Board
CPU UE15
Down S/W Program
Main board Power
Note: Using Cyclone Pro Tools down loadS/W
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
11/26
Main Board-Expand Board
Expand (Upgrade) Features:
System Input Expand to 3 Phases. System Expand Analog Input X 4 System Expand digital input X 2 System Battery Fuse Expand x 2
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
12/26
Connector I/P BoardFeatures: System Input AC Voltage Detection 1 Phase
(Expand to 3 Phases) System Output DC Voltage Detection System Battery Current Detection X 2 System Load Current Detection X 1
Battery Fuse Detect X 2 (Expand 2) Breaker(Plug-in) Detect 2 Rails Load Fuse/Breaker Detect X 13(Series Detection)
(Including GMT Fuse Detect X 1)
LVDS Control X 2 Environment Temp. X1 and Batt. Temp.X 2 8 Relay Alarm output ( From C type )
External Buzzer Alarm X 1 (Option )
Expand 4 Analog and 2 Digital I/P
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
13/26
BackEnter
Major LEDMinor LED
EQU LED
128 x 64 LCDDots Display
New Smart CSU: User Interfaces
Up Down
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
14/26
New Smart CSU Function Architecture* (Main\Data)
* Function architecture varies in different systems
Rectifier I.D. Address
Output CurrentStatus
Event Log Alarm Function Time
Recover Time
Current .settingDC Setting
Alarm SettingBatt.Setting
Other Setting
HomeDCVDCI
Sys Status(FL/EQU)
Alarm Existing
Sys Info Sys Setting Current Alarm
BatteryBatt. String I.D.
Batt.StatusBatt. Current
* DC/DC Data
AC & Temp ACV Voltage Ambient Temp.
Data &VersionDate/TimeH/W versionS/W version
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
15/26
New Smart CSU Function Architecture* (Main\Data)
* Function architecture varies in different systems
DC SettingDCV settingCL setting
Batt. SettingBatt. Par.T-CompBDT TestB-EQU
PasswordNew PWCfm PWDefault(0000)
HomeDCVDCI
Sys Status(FL/EQU)
Alarm Existing
Sys Info Sys Setting Current Alarm
Alarm Sett ing ACV,
DCV,LVDS,OTP,EQU,Batt.Test.
Password
Date SettingYear/month/
day/time
Alarm ResetReset HVSD
Reset Com-fail
Generator ON/OFF
LanguageEnglish
Efficn.t Mgt.ON/OFF
Comm.Modbus
Baudrate
Temp. Uni tON/OFF
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
16/26
New Smart CSU Function Architecture*(Main\Alarm)
* Function architecture varies in different systems
HomeDCVDCI
Sys Status(FL/EQU)
Alarm Existing
Sys Info Sys Setting Current Alarm
All Alarm Function show on DisplayShow Real Information and Alarm Time in Event
Log
Back Content
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
17/26
BATTERY CHARGE AND DISCHARGE CONTROL
Normal Operation
DistributionCapacity CountAC FailAC Fail
1 HrsCycle Count
EqualizeCharge 1 Hrs
Capacity Charge
Count
NO
YES
EqualizeCharge
NOYES Charge Current
10% I10
ChargeComplete
NO
NO
YES
YES
Float
AC Restored
YES
NO
ContinuousEqualize Charge
1 Hrs
NO
NO
YES
AccumulatedEqual ize Charge
10Hrs
YES
PeriodicallyEqualize Charge
Disc ha rge
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
18/26
33 battery recharge modes : Periodic, Manual, Deeply discharge modebattery recharge modes : Periodic, Manual, Deeply discharge mode Periodic mode: The battery was periodic recharge for compensating self-discharge of
battery. Manual mode: Technician th rough LCD or Remote control system to syst em control.
Deeply discharge mode: After system deeply di scharged (AC fail or battery test), systemneed rapid recharge battery.
Battery Maintenance - Benefit
g
Voa
a
g
e
Time
Stage 1 Current Limit
Stage 2 Current Limit
Stage 3 Current Limit
Float Voltage
Deeply DischargeVoltage
EqulizeVoltage
Battery current
0V / 0A EQU stop current
Deeply discharge mode:Deeply discharge mode: Af ter system deeply discharged, system provi de rapid and sui table batt ery recharge process to avoid batt erydamage and keep ful ly battery capacity anyti me. Adjustable parameters easy conf orm di fferent batterycharacteristic.
Battery Charge FunctionBattery Charge Function
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
19/26
Temperature compensation is to prevent the thermal runaway of battery when it is used in h igh t emperatureconditi ons and to secure to suffic ient charging of battery when it is used in low temperature conditions.
2 battery compensation modes: Easy and professional compensation pr ocess to satisfy battery characteristic.
Linear mode:Sample coeffici ents depict batterycompensation characteristic to satisfy generalbattery operation.
Temperature Reference(Default: 25 )
Battery Temperature()
Output Voltage (V)
FloatVoltage
Slope: Temperature coefficient(mV/)
Curve mode:Several parameters precise depic t specif ic batterycompensation characteristic to satisfy professionalbattery operation
Coefficient 2
Battery Temperature ( )
Coefficient 3
Coefficient 1
Output Voltage (V)
-15 10 30 50
Coefficient 4
Battery Maintenance - BenefitBattery Temperature CompensationBattery Temperature Compensation
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
20/26
Battery Discharge TestBattery Discharge Test
The propose of battery test i s battery backup funct ion confirmation. Control ler bases on accuracy dischargecurrent (Constant current) and discharge time to calculate battery lost capacity. Measurement of dischargecurrent is according to load discharge current.Operation mode: Periodic, Manual mode
Test Voltage
Test Time
System voltagein floating mode
Time
Voltage
OK
Fail
Battery Maintenance - Benefit
Periodic battery test:Some easy parameter settings (Month, Day, Hour, Cycle) to regular moni tor ing battery heath st atus. Contactdischarge current and adjustable test time precise simulate battery characteristic to enhance test result accuracy.
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
21/26
Green Energy Management - Benefit
Standby Standby Standby
Standby Standby Standby
WorkingRectifiers
E f f i c i e n c y
( % )
9 8 7 6 5 43
2 0
3 0
4 0
5 0
6 0
7 0
8 0
9 0
1 0 0
Rectifier Loading (%)
Efficient Curve AreaExample: 6000W load
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
22/26
Green Energy Management Control Philosophy
System is operating efficiency varies with O/P load.
The sweet spot is 50% and 90% of rated capacity.
Optimize operating effic iency to keep lowest
operational costs.
Real-Time load calculate & gradually turn off & on
rectifier to ensure system reliability.
TrueFalse
Load 60%
Turn On Off OneSMR
True
False
Turn On One SMRTurn Off One SMR
True
Time Elapsed> 12hr
False
True
Turn On All SMR
True
FalseLoad >
80%
OR Alarm
While True
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
23/26
Delta Power System Monitoring & Control
Build in HTTPWeb Server
ACDistribution Rectifiers
DCDistribution
BatteryManagement
EnvironmentData
Acquisition
Control &Supervisory
Unit
ClientUser
ClientUser
Internet
Telecom Power ManageProgram
Local
ClientUser
Mini USB
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
24/26
Local Access
M i n i U S B
NRMS Monitor software
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
25/26
Web Server Function and Feature (Optional)Features:
Applied in TCP/IP Internet/Intranet Environment
Complete Supervising to Power System
User-friendly Graphic Interface
Dynamic information presentation
Password function
Multi Language SupportMicrosoft Explorer and Netscape SupportMain Screen
StatusParameter Setting
Alarm Configuration
8/12/2019 04-2newsmartcsur00-130529203950-phpapp01
26/26
Q & A