Filtering efficiency rate is higher than 99.99% based on the minute particle of 0.3㎛, and this filtering efficiency is enhanced at the particles below and above 0.3㎛ by three principles; inertiar impaction, interception and diffusion.

The biological safety cabinet perfectly eliminates the possibility of contaminated air outflow from inside cabinet.It provides personnel, product and environment protections.

It prevents the direct inflow of the unpurified outside air into the inside of the chamber through the gap between the body and door sash when the front door is opened.

A blower supplying stable air flow assures the performance of low noise and non-vibration by optimizing parts and balance, and reduces the energy consumption.

The air current of the intake grille not to be disturbed by the researcher's arm, and perfectly blocks the UV light exposure when the door is closed.

Threshold

The sash alarm will be activated in case sash level is out of preset level, e.g. 8 inches height.

Width

Depth

Height

Frame height

Leveling caster height

Urethane caster height

<Top View> <Front View> <Side View>

1060/ 1385/ 1690/ 1995mm

810mm

1590mm

633mm

80mm

103mm

The work surface, which is easily disassembled from the equipment, is convenient for cleaning and maintenance.

Wide intake grille and reserved air hole perfectly prevent the cross contamination of the inside and outside of a work table. Wide armrest reduces the degree of researcher’s fatigue.

High performance blowerSash level

Intake grille & Armrest Non-filtered air protection hole

Biological Safety CabinetCHC LAB

Threshold structure &UV light leak free guard

Dished work surface

HEPA filter which eliminates the minute particles of 0.3㎛ by 99.99%Design

CHC-222A2 & CHC-777A2

biolus®

BIO SAFETY CABINET

TM

15

90

23

05

63

31

70

597

389 50

65

5

1060 / 1385 / 1690 / 1995

925 / 1250 / 1555 / 1860

06 07

www.chclab.com

Class II Type A2 | CHC-111A2 Class II Type A2 | CHC-222A2 Class II Type A2 | CHC-777A2 Class II Type B2 | CHC-888B2

PRODUCT LIST

Model No.CHC-111A2

04

Dimension(mm)

Width 1340

Depth 700

Height 2075

Color Gray

Door Tempered safety glass

Control panel LCD Display panel

Sash level 203 mm (8inch)

External material SPCC / AL with epoxy powder coated

Chamber material STS 304

Certification X

Avg. inflow velocity 0.3 ~ 0.4 m/s

Avg. Downflow velocity 0.25 ~ 0.35 m/s

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Noise level (dB) < 62

Nominal exhaust volume 312 CMH

Power supply 220V, 50/60Hz

FL lamp 36W X 1EA

UV lamp 30W X 1EA

Power receptacle 220V X 2EA

Utility valve 1EA (Vacuum)

Drain valve X

Differential pressure gauge O

Duct (Ø) X

Hard exhaust connection Option

Airthight damper X

Exhaust airflow sensor X

Model No.CHC-222A2

03 04 05 06

Dimension(mm)

Width 1060 1385 1690 1995

Depth 810

Height 2305

Color Gray

Door 6.38mm Laminated glass

Control panel LCD Display panel

Sash level 203 mm (8inch)

External material SPCC / AL with epoxy powder coated

Chamber material STS 304

Certification - EN, CE - EN, CE

Avg. inflow velocity 0.53 m/s (105fpm)

Avg. Downflow velocity 0.35 m/s (70fpm)

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Noise level (dB) < 64 < 65

Nominal exhaust volume 358 CMH 484 CMH 602 CMH 720 CMH

Power supply 220V, 50/60Hz

FL lamp 36W X 2EA

UV lamp 30W X 1EA

Power receptacle 220V X 2EA

Utility valve 1EA (Vacuum)

Drain valve Option

Differential pressure gauge O

Duct (Ø) X

Hard exhaust connection Option

Airthight damper X

Exhaust airflow sensor X

Model No.CHC-888B2

04 06

Dimension(mm)

Width 1385 1995

Depth 810

Height Leveling caster - 2540 / Fixed foot - 2503

Color Gray

Door 6.38mm Laminated glass

Control panel LCD Display panel

Sash level 203 mm (8inch)

External material SPCC / AL with epoxy powder coated

Chamber material STS 304

Certification NSF, UL

Avg. inflow velocity 0.53 m/s (105fpm)

Avg. Downflow velocity 0.30 m/s (60fpm)

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Noise level (dB) < 64 < 65

Nominal exhaust volume 1390 CMH 2092 CMH

Power supply 220V, 50/60Hz

FL lamp 36W X 2EA

UV lamp 30W X 1EA

Power receptacle 220V X 2EA

Utility valve 1EA (Vacuum)

Drain valve Option

Differential pressure gauge O

Duct (Ø) 200 or 250

Hard exhaust connection O

Airthight damper O

Exhaust airflow sensor O

Model No.CHC-777A2

03 04 05 06

Dimension(mm)

Width 1060 1385 1690 1995

Depth 810

Height 2305

Color Gray

Door 6.38mm Laminated glass

Control panel LCD Display panel

Sash level 203 mm (8inch)

External material SPCC / AL with epoxy powder coated

Chamber material STS 304

Certification NSF, UL, KS UL, KS NSF, UL, KS

Avg. inflow velocity 0.53 m/s (105fpm)

Avg. Downflow velocity 0.35 m/s (70fpm)

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Noise level (dB) < 64 < 65

Nominal exhaust volume 358 CMH 484 CMH 602 CMH 720 CMH

Power supply 220V, 50/60Hz

FL lamp 36W X 2EA

UV lamp 30W X 1EA

Power receptacle 220V X 2EA

Utility valve 1EA (Vacuum)

Drain valve Option

Differential pressure gauge O

Duct (Ø) X

Hard exhaust connection Option

Airthight damper X

Exhaust airflow sensor O

Biological Safety CabinetCHC LAB

● Room air● HEPA filtered air● Contaminated air under negative pressure● Contaminated air under positive pressure

● Room air● HEPA filtered air● Contaminated air under negative pressure● Contaminated air under positive pressure

● Room air● HEPA filtered air● Contaminated air under negative pressure● Contaminated air under positive pressure

● Room air● HEPA filtered air● Contaminated air under negative pressure

Airflow Airflow Airflow Airflow

09

www.chclab.com

08

Laminar flow cabinet provides only product protection for researcher. Biological safety cabinet provides personnel, product and environment.

Laminar flow cabinetClean air through HEPA filter flows inside chamber and protect product from contaminated air

Biological safety cabinet70% of the airflow at work space is re-circulated through the HEPA Filter, and 30% of it is exhausted to the outside through HEPA filter, and the polluted airflow is not leaked as perfectly surrounded by the negative pressure.

The product classified as BSL 1, harmless to human will be treated in laminar flow cabinet, and the product classified as BSL 2 or 3, high risk to human will be treated in biological safety cabinet.

Laminar flow cabinet provides primarily product protection from contamination. It is suitable when the specimen with comparatively less danger of contamination is treated, or suitable for the experiment of DNA, RNA, and PCR.

Laminar Flow CabinetCHC LAB

Laminar flow cabinet and Biological safety cabinet differences

Des

ign

Ergo

nom

ic

biolus®

LAMINAR FLOW CABINET

All the operations can be controlled with one controller.

■ Polluted air■ Clean air■ Particle

It can be easily moved to any desired places as the caster of stopper function is attached.

Electrical receptacle with safety cover is for the convenience of the experiment in work space. utility valves are available to be installed, gas, air, water and vacuum.

Differential pressure gaugeHEPA filter

Electrical receptacle &Utility valve LCD Display panelLeveling caster

Width

Depth

Height

Frame height

Leveling caster height

<Top View> <Front View> <Side View>

1040/ 1340/ 1650/ 1960mm

742mm

1231mm

633mm

82mm

Design

CLB-201 & CLB-201S By usage purose

By airflow

By product

It is available to check filter replacement time.

High efficiency particulate air filter

Particles of 0.3㎛ (dusts, bacteria, virus etc.) are removed by more than 99.99%

10

PRODUCT LIST

Model No.CLB-201

03 04 05 06

Dimension(mm)

Width 1040 1340 1650 1960

Depth 742

Height 1946

Color Gray

Door Tempered safety glass (5mm)

Control panel LCD Display panel

External material SPCC / AL with epoxy powder coated

Worktop STS 304

Support frame SPP

Certification CE

Avg. Downflow velocity 0.3~0.4 m/s (Variable set speed)

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Pre-filter Nylon filter

Noise level (dB) ≤ 65 dB(A)

Safety alarm UV timer

Power supply 220V, 50/60Hz

FL lamp 36W X 1EA 36W X 2EA

UV lamp 20W X 1EA 30W X 1EA

Power receptacle 220V X 1EA 220V X 2EA

Utility valve Option

Utility hole Option

Differential pressure gauge O

Model No.CLB-201S

03 04 05 06

Dimension(mm)

Width 1040 1340 1650 1960

Depth 742

Height 1946

Color Gray

Door Tempered safety glass (5mm)

Control panel LCD Display panel

External material SPCC / AL with epoxy powder coated

Worktop STS 304

Support frame SPP

Certification CE

Avg. Downflow velocity 0.3~0.4 m/s (Variable set speed)

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Pre-filter Nylon filter

Noise level (dB) ≤ 65 dB(A)

Safety alarm UV timer

Power supply 220V, 50/60Hz

FL lamp 36W X 1EA 36W X 2EA

UV lamp 20W X 1EA 30W X 1EA

Power receptacle 220V X 1EA 220V X 2EA

Utility valve Option

Utility hole Option

Differential pressure gauge O

Model No.CLB-202D

03 04 05 06

Dimension(mm)

Width 1040 1340 1650 1960

Depth 777

Height 2015

Color Gray

Door Basic - Tempered glass / Option - Acrylic panel door

Control panel LCD Display panel

External material SPCC / AL with epoxy powder coated

Worktop STS 304

Support frame SPP

Certification CE

Avg. Downflow velocity 0.3~0.4 m/s (Variable set speed)

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Pre-filter Nylon filter

Noise level (dB) ≤ 65 dB(A)

Safety alarm UV timer

Power supply 220V, 50/60Hz

FL lamp 36W X 1EA 36W X 2EA

UV lamp 20W X 1EA 30W X 1EA

Power receptacle 220V X 2EA

Utility valve Option

Utility hole Option

Differential pressure gauge O

Model No.CLB-060F

03 04

Dimension(mm)

Width 906 1206

Depth 660

Height 1876

Color Gray

Door Front folding sash, (Acrylic 8mm)

Control panel LCD Display panel

External material Steel plate with epoxy powder coated

Worktop STS 304

Support frame SPP

Certification CE

Avg. Downflow velocity 0.3~0.4 m/s (Variable set speed)

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Pre-filter Nylon filter

Noise level (dB) ≤ 65 dB(A)

Safety alarm UV timer

Power supply 220V, 50/60Hz

FL lamp 36W X 1EA 36W X 2EA

UV lamp 10W X 1EA 10W X 2EA

Power receptacle 220V X 1EA

Utility valve X

Utility hole X

Differential pressure gauge X

● Room air● HEPA filtered air

● Room air● HEPA filtered air

● Room air● HEPA filtered air

● Room air● HEPA filtered air

11

www.chclab.com

Vertical Laminar Flow Cabinet Vertical Laminar Flow Cabinet Horizontal Laminar Flow Cabinet Laminar Flow Cabinet

Airflow Airflow Airflow Airflow

Laminar Flow CabinetCHC LAB

WorkstationCHC LAB

A-STWS-900 A-STWS-1100

A-STWS-900F A-STWS-1100F

It is mainly used in animal laboratory to remove harmful gas or odor in order to protect the researcher.

Simple washing is available during the experiment as cupsink and water tap are installed.

Applying the three-sided acrylic observation, it is so easy to obtain the best possible view inside.

Cup Sink & Water Tap Three-sided Acrylic

Unit : mm

12

airos® Safrty Trimming

Workstation

Airflow

● Room Air● Fume (gas, vapor)● Clean Air

13

Lab Furniture CHC LAB

Finter Box (CLE-030)

Dimension500 X 500 X 865 (WxDxH)FilterCarbon / HEPA / Pre-filter

Safety Trimming Workstation

Width Depth Height

906 / 1106 560 1405

Safety Trimming Workstationwith Filter Box

Width Depth Height

906 / 1106 560 1405

Ergonomic

Lab ChairBimos, laboratory chair with European design provides comfort for a long time using ergonomic design.

Seat height adjustment

Auto-motion technology Seat height adjustment Backrest height adjustment

Seat swivel range of 20ㅇ

to the left and right

Functions

Lab Stool (Backrest)

Labster Fin

Lab Stool

Cleanroom Plus

Black

BlackBlack

BlackGrayWhiteGray

Order No.White : 9103-6907Gray : 9103-6911

Model No.Black : CLF-932

Order No.Black : 9144-2000Gray : 9144-2002

Model No.Black : CLF-925

Order No.Black : 9181-2571

Features

FRP (Clean Room Only)

White

Model No.White : Decois-8170

CHC LAB Co.,Ltd. Product List

Lab Furniture hulab® - LEVEL PRO® Lab table

- HARD PRO® Lab table

- COZY PRO® Lab table

Ventilation System airos® - Bypass air fume hood - Air curtain fume hood - Auxiliary air fume hood - Low work-in fume hood - Walk-in fume hood - Center tabletop fume hood - Side tabletop fume hood - Arm hood

Filtering System cleair® - Ductless fume hood - Chemical storage cabinet (2in1 filter type) - Chemical storage cabinet (Ion cluster type)

Bio Equipment biolus® - Biological safety cabinet Class I - Biological safety cabinet Class II Type A2 - Biological safety cabinet Class II Type B2 - Vertical laminar flow cabinet - Horizontal laminar flow cabinet - Laminar flow cabinet - PCR Workstation

Workstation airos® - Safety balance workstation - Safety trimming workstation

CHC LAB Co.,Ltd. Head office & factory139, Techno 2-ro, Yuseong-gu, Daejeon, KoreaTel.+82-42-933-0036 Fax.+82-42-933-0039

Chungwon factory336-8, Biryong-ri, Nami-myeon, Seowon-gu, Cheongju-si, Chungbu, KoreaTel.+82-43-277-8475 Fax.+82-43-277-8476

Seoul Branch office#207, 140, Beolmal-ro, Dongan-gu, Anyang-si, Gyeonggi-do, KoreaTel.+82-31-423-5530 Fax.+82-31-423-5542

Web Sitehttp://www.chclab.com

Social Networkhttp://www.facebook.com/chclab | http://www.twitter.com/chchulab

Bloghttp://blog.naver.com/chclabblog

[email protected]