//Data Center Checklist
Company profile 1 2 3publicly held or venture backed
multiple data centers
multiple service locations
reputable reference accounts
Core competency – designs, engineers and delivers data center products and servicesprovides a 100% uptime Slaoffers modular data center products and servicesoffers enterprise-grade “private cloud” infrastructure as a ServiceStandardized data center hardwareoffers software optimized data center infrastructuremeets ultra-high security requirementsTier III Design Certified by the Uptime Institute
environmental threatS & loCation earthquakestornadoeshurricanesTidal floodingRiver floodingtsunamiBlizzards/hail stormsLocated in flood plainLocated in flight pathadjacent to highway with hazardous shippingadjacent to railroad trackseasily accessible from airport/highwayDistance from street (# feet)major delivery services available
Core power 1 2 3total capacity available at data center (# mw)on-site substation
If yes, is substation dedicated to provider’s use?Diverse high voltage feeds from utility
If yes, what is capacity (in kV/KVA)?
CritiCal power# backup generators on-sitetotal backup capacity currently available (# mw)# gallons diesel fuel stored on-sitehow long at full load? (# minutes)Proximity to diesel fuel filling station (# miles)Battery backup capacity at load (# minutes)
UnInTeRRUPTIbLe ConDITIoneD PoweRConcurrently maintainable designUPS currently available (# Mw)Total UPS available at site (# Mw)Diverse UPS manufacturersDiverse PDU manufacturersPower density across entire data center (watts UPS/SF)Spot densities per square foot (# watts)Color-coded power cablinghand-sewn, wax string used
overhead cablingDaTa CenTeR STRUCTURe 1 2 3LeeD CertifiedSteel reinforced concreteSquare footage# storieson-site office space# freight elevators# truck/shipping baysBurn-in staging center availableSecure storagemanaged shipping and receiving
ComplianCe availaBle 1 2 3SaS 70 / SSae 16
pCi
hippa
list of providers1 ____________________________2 ____________________________3 ____________________________
proviDerS proviDerS
energy effiCienCyleD lightingmotion activated lightingUltrasonic humidificationvariable frequency drive chillersvariable frequency drive pumpsvariable frequency drive cooling towersvariable frequency drive air handlersSealed cabinetsinsulated roof
1225 W Burnside Street, Suite 310 Portland, OR 97209 // www.opusinteractive.com // 503.972.6677 // ©Opus Interactive 2012
//Data Center Checklist
aCCeSS ControlTraffic bollards/car trapsDigital video surveillanceCustomer defined access listsvisitor trackingBiometric screeningmantrapslocking cabinets, cages, suites and modulesprivate access control systems allowed24x7xforever customer access without delay
environmental ControlS 1 2 3Discreet plC system automationredundant controllers
hSSD smoke detectioninterlocked, multi-zone, pre-action dry pipe and clean agent gas fire suppressionrope-style leak detectionSingle point grounding systemUL approved perimeter lightning protection system
effiCienCy 1 2 3thermal energy Storage (teS) option available% of time free cooling can be used
network CarrierS 1 2 3at&tabovenetaCS alaskaCogentComcastglobal Crossinghe.netintegra telecomlevel 3lS networkspaetec (windstream)SilverStar telecomverizon Business Spectrum networkstata
tw telecom
Xo
Zayo (360 networks)
network ConneCtivityfree cross-connectsCarrier-neutralon-site meet-me-room# diverse fiber entry vaults# network providers on-site with gateway accessenterprise-grade internet bandwidth w/minimum10gB connections to each providerprivate data transport between data centersDark fiber availablewireless service available
SUPPoRT SeRvICeSComplimentary remote hands24x7 on call engineersmanaged Services options
proviDerS proviDerS
heat rejeCtion 1 2 3# of compressors/chillers# evaporation towersCapacity of chilled water plant (#tons)Bi-directional, welded, valved chilled water loop
waterDiverse water mains# gallons water stored on-siteDomestic well on-site
air hanDlingConcurrently maintainable design# modular Crah unitsCapacity of Crah units (kw or tons per unit)High-efficiency raised floorHigh-efficiency chilled water systemvariable speed plug fans