Single Pole and 3-Way Wide View Motion Activated Light … Screw marked Red (RD) 2 Terminal Screw...

Preview:

Citation preview

WARNINGS AND CAUTIONS:• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!• Tobeinstalledand/orusedinaccordancewithelectricalcodesandregulations.• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,DO NOTinstalltocontrolareceptacle,amotor,oratransformer-operatedappliance

otherthanapplicablespecifiedlightingload:IncandescentandLED.• Whenusingina3-wayapplicationuseonesensorandonestandard3-wayswitch.Cannotbeusedwithanothersensor,orina4-wayapplication.

WARNINGS AND CAUTIONS:• Ifyouarenotsureaboutanypartoftheseinstructions,consultanelectrician.• Cleanoutersurfacegentlywithdampclothonly.DO NOT usesoapsorcleaningliquids.• Nouserserviceablecomponents.DO NOT attempttoserviceorrepair.• UsethisdeviceWITH COPPER OR COPPER CLAD WIRE ONLY.

RESETRESET

TESTTEST

1 2

0 3

Push down tabs per diagram, one at a time and rotate forward to release

1 2

0 3

1 2

0 3

Attach new face by inserting bottom hinge tabs, then pivot and snap the color kit to attach

TOOLS NEEDED TO INSTALL YOUR DEVICE

Slotted/PhillipsScrewdriver ElectricalTape PliersPencil Cutters Ruler

Changing the color of your device:Yourdevicemayincludecoloroptions.Tochangecolorofthefaceproceedasfollows:

BK

RD3-Way

TerminalScrew marked

Red (RD)

2

TerminalScrew marked

Black (BK)

BrassTerminal Screw

Marked 3-Way

Terminal Label:Use Terminal for 3-Way Applications Only.For Single Pole Applications, Do Not Remove This Label.

4

1

3

Ground(Green Screw)

Sensor

Single Pole and 3-Way Wide View Motion Activated Light ControlCat. No. IPS06, IPV06 - INDOOR USE ONLY

Ratings:120VAC,60Hz600WIncandescent&150WLED

INSTALLATION INSTRUCTIONS

PK-93978-10-00-2A

FEATURES• Cat.No.IPS06andIPV06haveasensingareaofcoverageof

30ft.x30ft.,andasensingangleof180O (see Sensing Area Coverage figure on page 2).

• Adjustablelightandtime-delaycontrolsarelocatedonthefrontofthedevice(See adjustment setting section on page 2 for details).

• LEDindicatorisusedtoalerttheuserofthestatusofthedevice.• AdjustableTimeDelaysettingfor30seconds,5min,15min

&30min.• Occupancysensorcanbeconvertedtoavacancysensor

(See adjustment settings on page 2).

LOCATION / MOUNTINGThedevicerespondstotemperaturechangesandcareshouldbetakenwhenmountingthedevice.DO NOTmountdirectlyaboveaheatsource,inalocationwherehotorcolddraftswillblowdirectlyonthesensor,orwhereunintendedmotion(e.g.,hallwaytraffic)willbewithinsensor’sfield-of-view.

Sensor is located in electrical box with LINE connection:C

Hot (Black)

Neutral (White)

BK

LOAD

Line120VAC60 Hz

Sensor

GreenGround

3-Way/Brass

3-Way Switch

Common Terminal(Black Screw)

Pigtail

PigtailGreenGround

RD

First Traveler

Second Traveler

Hot (Black)

Neutral (White)

BK

LOAD

Line120VAC60 Hz

Sensor

GreenGround

GreenGround

3-Way/Brass

3-Way Switch

Common Terminal(Black Screw)

Pigtail

Pigtail

First Traveler

Second TravelerRD

BK

RD3-Way

2

3-Way Switch

2

Sensor

1

3

5

CommonTerminal

(BlackScrew)

Ground(Green Screw)

1

4

43

5

CommonTerminal

(BlackScrew)

Ground(Green Screw)

BK

RD3-Way

2

Sensor

3

5

1

4

3-Way Switch

21

5

4

3

B Sensor is located in electrical box with LOAD connection:

WIRING SWITCH:Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• OnepigtailwiretotheBlackscrewterminalmarked"COM"and

onepigtailwiretotheBrassterminal(same side of switch).• Connectthefollowing4wiresusinganappropriatelysized

wirenut: 1. Common/Linewire(identified in step 2). 2. SecondTravelerwire(note color from step 2). 3. Twopigtailwiresfromthe3-wayswitch.• FirstTravelerwallboxwire(note color from step 2)to

Brassscrewterminalontheswitch(opposite side from the Black screw).

WIRING SENSOR:Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Common/Loadwallboxwireidentifiedwhenremovingold

switch(step 2)toterminalscrewmarked"BK".• FirstTravelerwallboxwire(note color from step 2)toterminal

screwmarked"3-way".• SecondTravelerwallboxwire(note color from step 2)to

terminalscrewmarked"RD".ThisTravelerfromtheswitchmustgototheterminalscrewonthesensormarked"RD".

WIRING SENSOR:Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Common/Linewallboxwireidentifiedwhenremovingoldswitch

(step 2)toterminalscrewmarked"BK".• FirstTravelerwallboxwire(note color from step 2)toterminal

screwmarked"RD".• SecondTravelerwallboxwire(note color from step 2)to

terminalscrewmarked"3-way".

WIRING SWITCH:Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• OnepigtailwiretotheBlackscrewterminalmarked"COM"and

aonepigtailwiretothebrassterminal(samesideofswitch)• Connectthefollowing4wiresusinganappropriatelysized

wirenut: 1. Common/Loadwire(identified in step 2). 2. FirstTravelerwire(note color from step 2). 3. Twopigtailwiresfromthe3-Wayswitch.• SecondTravelerwallboxwire(note color from step 2)to

Brassscrewterminalontheswitch(opposite side from the Black screw).

IMPORTANT:For3-wayapplications,notethatoneofthescrewterminalsfromtheoldswitchbeingremovedwillusuallybeadifferentcolor(Black)orlabeledCommon.Tagthatwirewithelectricaltapeandidentifyasthecommon(LineorLoad)inboththesensorwallboxandremotewallbox.

3-Way1. LineorLoad (See important

instruction below)2. Neutral3. Ground4. FirstTraveler–notecolor5. SecondTraveler–notecolor

2

4

3

1

Single-Pole1. Line(Hot)2. Neutral3. Ground4. Load

Step 2 Identifying your wiring application (most common):NOTE:Ifthewiringinthewallboxdoesnotresembleanyoftheseconfigurations,consultanelectrician.

Preparing and connecting wires:Thisdevicecanbewiredusingsidewireterminalscrews.Chooseappropriatewirestrippingspecificationsaccordingly.

• Makesurethattheendsofthewiresfromthewallboxarestraight (cut if necessary).

• Removeinsulationfromeachwireinthewallboxasshown.• For Single Pole Application, go to Step 4A.• For 3-Way Application with the sensor on the Load side, go to Step 4B.• For 3-Way Application with the sensor on the Line side, go to Step 4C.

Strip Gage (measure bare wire here or use gage on back of the sensor)

5/8”(1.6 cm)

Cut(if necessary)

Side Wire ConnectionSidewireterminalsaccept#14-12AWGsolid copper wire only.

Step 3

Back Wire Connection Backwireopeningsuse#14-12AWGsolid copper wire only.

BK

RDYL 3-Way

2

4

1

5

3

√INSTALLING YOUR DEVICE

NOTE: UsecheckboxeswhenStepsarecompleted.

ONOFF

ONOFF

ONOFF

ONOFF

ONOFF

ONOFF

ONOFFONOFF

ONOFF

ONOFF

ONOFF

ONOFF

Step 1 WARNING:TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWERatcircuitbreakerorfuseandtestthatpowerisoffbeforewiring!

WIRING SENSOR:Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHotwallboxwiretoterminalscrewmarked"BK".• Loadwallboxwiretoterminalscrewmarked"RD".• Terminalscrewmarked"3-way"shouldhaveRedinsulationlabel

affixed.NOTE: Ifinsulatinglabelisnotaffixedtoterminalscrewmarked"3-way",useelectricaltapetocover.

• ProceedtoStep5.

Use Terminal for 3-WayApplications Only.For Single Pole Applications,Do Not Remove This Label.

Hot (Black)

Neutral (White)

RDBlack

BK

White

LOAD

Line120VAC, 60 Hz

Sensor

GreenGround

3-Way(BrassScrew)

Step 4 Single Pole Wiring Application:

A

3-Way Wiring with 3-Way Switch Application:

Whenconnectingthesensorfor3-waycontrol,firstchoosewhichwallswitchlocationthesensorwillbeinstalledin.Next,identifywhichelectricalboxhasthelineconnection.Ifthelineconnectionisintheboxwherethestandard3-wayswitchislocated,usewiringdiagram4B.Ifthelineconnectionisintheboxwherethesensorislocated,usewiringdiagram4C.NOTE: Apairofshortpigtailwireswillbeneededforconnectiontothe3-wayswitch.

LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLevitonwarrants to theoriginalconsumerpurchaserandnot for thebenefitofanyoneelse that thisproductat the timeof itssalebyLeviton is freeofdefects inmaterialsandworkmanshipundernormalandproperuse forfiveyears fromthepurchasedate.Leviton’sonlyobligation is tocorrectsuchdefectsby repairor replacement,at itsoption, ifwithinsuchfiveyearperiod theproduct is returnedprepaid,withproofofpurchasedate,andadescriptionof theproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747.Thiswarrantyexcludesand there isdisclaimed liability for labor for removalof thisproductor reinstallation.Thiswarranty isvoid if thisproduct is installed improperlyor inan improperenvironment,overloaded,misused,opened,abused,oraltered inanymanner,or isnotusedundernormaloperatingconditionsornot inaccordancewithany labelsor instructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any impliedwarranty is requiredby theapplicable jurisdiction, thedurationofanysuch impliedwarranty, includingmerchantabilityandfitness foraparticularpurpose, is limited tofiveyears.Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.The remediesprovidedhereinare theexclusive remediesunder thiswarranty,whetherbasedoncontract, tortorotherwise.

PK-93978-10-00-2A©2012LevitonMfg.Co.,Inc.

• Positionallwirestoprovideroominoutletwallboxfordevice.• Ensurethattheword"TOP"isfacingupondevicestrap.• Partiallyscrewinmountingscrewsinwallboxmountingholes.

• Restorepoweratcircuitbreakerorfuse.• ForIPS06lightswillautomaticallyturnON

afterpowerisapplied.• ForIPV06pressamdreleasepushpadto

turnthelightsON. See Locator Light Status chart to

confirm the operational state of the device.

If lights still do not turn ON, refer to the TROUBLESHOOTING section.

Testing your Device prior to mounting in wall box:

Step 5

Restore Power:Restorepoweratcircuitbreakerorfuse.

Installation is complete.

Step 7

Device Mounting:TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.

Step 6

Installationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate.

OPERATION

Locator Light LED:IPS06:LEDblinkswhenmotionisdetectedandiftheloadisONorOFF.

IPV06: LEDblinkswhenmotionisdetectedandwhenloadisON.LEDwillremainilluminatedwhenloadisOFF.

NOTE: Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice.

For additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at www.leviton.com

ThisproductiscoveredbyU.S.Pat.No.7,924,155andcorrespondingforeignpatents.

©2012LevitonManufacturingCo.,Inc.AllRightsIncludingTradeDressRightsReserved

TROUBLESHOOTING

Lights do not switch ON - IPS06:• Motionisbeyondsensingrange,moveclosertoswitch.• Adjustthelightleveladjustmenttowardlighterordarker,

dependingonroomconditions.Lights always stay ON:• Checktimedelaysettingsandcomparetohowlongthelights

stayON.• Besurethatnomotionoccursincoverageareafortime

selected.• Checkthatswitchisnotinstallednearaheatsource(e.g.,stove,

lights,heatvents)ordetectingmotionfromanadjacentarea(e.g.,hallwaytraffic).Ifso,switchmayhavetoberelocated.

Lights do not turn ON - IPV06:• Checkthatswitchisinstalledcorrectly.• CheckthatpowerisON.• Checkthatlightbulbisfunctioning.

NOTE:Ifproblemscontinue,consultanelectrician.

ADJUSTMENT SETTINGS1. Withpowerrestoredandwallplateremoved,removefaceof

devicetoexposesettingcontrols,seecolorchangeinstructionsinpage1.Useasmallscrewdrivertoadjustthelightsensitivityandtimesettingsonthedeviceasfollows:

Light Level Adjustment: •Adjustthelightleveldialclockwise.LightswillturnONinlighter

conditions.•Adjustthelightleveldialcounterclockwise.LightswillturnON

inlesslightingconditions.

•Adjustinglightlevelfullycounterclockwisewillrequiremanualoperationofthesensor.

Time Selection:• Adjustthetimeselectordialtothedesiredlengthoftimethe

lightsaretoremainON.LightswillremainONfrom30secondsto30minutesaftertheroomisvacated.

• AdjustthetimeselectordialclockwisetoincreasethedurationoftheONtimeupto30minutes.

• AdjustthetimeselectordialcounterclockwisetodecreasethedurationoftheONtimedownto30sec.

2. Testthatthelightlevelandtimeselectionareasdesired.Ifnot,repeatadjustmentsuntilsatisfied.

3. Mountwallplate.INSTALLATION IS COMPLETE.

IPS06Auto On: LightswillautomaticallyturnONwhenroomisoccupiedormotionisdetected.TheIPS06willswitchlightsOFFwhennomotionisdetectedinun-occupiedroomaftersetperiodoftime.

Time delay adjustment:RefertosectiononAdjustmentSettings.

Light level adjustment:RefertosectiononAdjustmentsettings.

Manual ON: TheIPS06willmanuallyturnONlightsortheloadbydepressingthepushpadonthedevice.

IPV06Manual ON:TheIPV06requirestheusertomanuallyturnONlightsortheloadbydepressingthepushpadonthedevice.

ThelightsorloadwillautomaticallyturnOFFwhentheroomisleftun-occupiedforasetperiodoftime.

TheIPV06canalsobeturnedoffmanuallybydepressingthepushpad.

Time delay adjustment:refertosectiononAdjustmentsettings

Light Level Adjustment

Time Selection 1 2

0 3

1 2

0 3

Settings Time

0 30Sec

1 5Min

2 15Min

3 30Min

Push Pad

LOCATOR LIGHT STATUS

LOAD IPS06 IPV06

OFF Blinking Lit

ON Blinking Blinking

NOTE:Ina3-wayapplication,the3wayswitchprovidestheabilitytomanuallyswitchtheloadONfromasecondlocation.ThesensorwilltimeoutandswitchtheloadOFFoncemotionisnolongerdetectedandthetimedelayexpires.

SENSING AREA COVERAGE

Field-of-View (Horizontal)

Side (Vertical) Field-of-View

1.5m5ft

30ft9.1m

30ft9.1m

6ft1.7m

1.8m6ft

5ft1.5m

30ft9.1m

1.4m4ft

8.4m27ft

2.1m7ft

1.5m5ft

1.2m4ft

1.7m6ft

2.6m8ft

LocatorLight

Lens

FCC COMPLIANCE STATEMENTThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttofollowingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperationofthedevice.ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:•ReorientorrelocatethereceivingAntenna.•Increasetheseparationbetweentheequipmentandthereceiver.•Connecttheequipmentintoanoutletonacircuitdifferentfromthatto

whichthereceiverisconnected.•Consultthedealeroranexperiencedradio/tvtechnicianforhelp.

FCC CAUTIONAnychangesormodificationsnotexpresslyapprovedbyLevitonManufacturingCo.,Inc.,couldvoidtheuser'sauthoritytooperatetheequipment.

NOTE: TooperatetheIPS06asavacancysensor(manualON/AutoOFF)-rotatethelightleveladjustmentfullycounterclockwise.

FOR CANADA ONLY

Forwarrantyinformationand/orproductreturns,residentsofCanadashouldcontactLevitoninwritingatLeviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9orbytelephoneat1 800 405-5320.

Recommended