Introducing GAC’s New Line of Intelligent Generator Set Controllers

Preview:

DESCRIPTION

Introducing GAC’s New Line of Intelligent Generator Set Controllers. The InteliGen. Stand-By, Prime Mover (single and multiple set), and Parralel to Utility (single and multiple set) Applications Features: 128 x 64 LCD 9 / 9 Discrete Inputs and Outputs (Configurable) Expandable - PowerPoint PPT Presentation

Citation preview

Introducing GAC’s New Line of Intelligent Generator Set Controllers

The InteliGen• Stand-By, Prime Mover (single and multiple set), and Parralel to Utility (single and multiple set) Applications• Features:

128 x 64 LCD9 / 9 Discrete Inputs and Outputs (Configurable) Expandable

to 21 / 213 Analog Inputs (Fuel Level, Coolant Temp., Oil Press.)

Expandable to 7 and 1 Analog OutputSpeed Measurement (Mag Pick-Up)3 Phase Generator / Utility Voltage Measurement3 Phase Generator Current Measurement1 CT Input for Utility Measurement or Earth Fault ProtectionRS232 for Direct CommunicationMeets NFPA110 (w/ Annunciator Module iGL-RA15)Remote Communication (Analog, Internet, and GSM)

InteliGen Connections3 Phase Generator Voltage 9 Configurable

Discrete Inputs

Direct PC or Modem Connection

12 or 24 V DC

3 Analog Inputs (Oil, Temp., Fuel.)

Mag. Pick-up

2 Relay Outputs (Starter, Fuel Solenoid) 7 Config. Outputs

Connection forIOM / COM

Module

3 Phase Utility Voltage

Connection for Power Modules

Utility Current

and Current

InteliGen’s Modules

• Power Control Modules: PCM and PCLSM (with Load Sharing)

• AVR control (needs 18 V AC power supply)• Communications• Expandable I / O• Modem Support (multiple set applications)

Power Control ModulesShielded Analog Load Sharing Line (PCLSM

only)

Governor Control Output

AVRi Output

4 Discrete Inputs 4 Discrete Outputs

12 or 24 V DC

Mounts Directly to Back of InteliGen

AVRi Module

Input from PCLSM

18 V AC Power Supply

Output for AVR Control

DIN Rail Mounting

Output Level Adjustment (turn pot)

Communication Module

• Used for Multiple Set Applications• Communications Between Sets• Mount: Back of InteliGen• Up to 32 Sets • Use one Modem (w/iG-MU)• RS232 port for IOM

IOM / PTM Module

PO WER

8-36V DC

BIN ARY OUTPUTS

BIN ARY INPU TS AN ALOG INPU TS AN ALOG OUT

BO

8B

I8

BI7

BI6

BI5

BI4

BI3

BI2

CO

M AI4

BI1

BO

1

BO

2

BO

3

BO

4

BO

5

BO

6

BO

7S eria l No.

IG-IO M

IG-C

U

RS

232

9 Discrete Inputs w/ Active LED

4 Analog Inputs* 1 Analog Output

12 or 24 V DC w/Power LED

9 Discrete Outputs w/ Active LED

RS232 Connection to InteliGen

RS232 for Direct PC Connection

DIN Rail Mounting

InteliMains: InteliGen With Special Software

• Mains (= Utility) Circuit Breaker Control–Reverse Synchronization–Vector surge protection (locally required)

• Power Management - Engine Usage Optimization–Number of running engines: Dependent on required load–Engine starting order: Dependent on running hours

• Import/Export Control

Parallel To Utility & Other Gen Set’s

G

G+ iG-COM +

iG-PCLSM

iG-PCLSM

iG-C

OM

+ iG-COM + iG-PCLSM

iG-PCLSM

iG-C

OM

InteliMains

InteliGen’s User Friendly Operating Software

• Free•User Friendly• PC Format

Controller Setpoints

ValuesHistory

Value Screen

All Metered Values in Real Time.

Screen Selection

Metering

History

• Every Action Logged• All Values Associated w/ that Action• Up to 177 events (FIFO)

Controller• Same as Keypad• Essential Metering• Alarm List

Setpoints• Change any Setpoint • Current Value• Range

Screen Selection

Value

Acceptable Rangefor Parameter

Customizable Software• Parameters

Nominal RPM 80 300• Multilingual Texts

Overspeed Überdrehzahl Sobrevelocidad• Units

°C F; kPa bar psi• Controller Operating Mode

SPM SSB SPtM MINT MEXT• Text

Water temp Coolant temp

Local connection to the Control System

Modem connection to remote monitoring*

SMS (Mobile phones) connection*

Internet connection*

Communications

Controller Screens

Water Temp 91°C

Oil Pressure 5.1bar

Fuel level 75%

Battery voltage 25.2V

• Analog Meters• Bar Graphs• Numeric Values• Controller Screens Allow for Similar Interface as WinEdit Software

MAINS:230 228 233V 50.0Hz GENERATOR: 1517RPM221 223 220V 50.6Hz872 896 932A 0.98L 183 194 208kW 118kVAr

Running in Island

Setpoint Adjustment

PARAMETERS MF-Start Delay 3sStart Attempts 5 Mains OK-Delay 10sCooling time 30s

• Adjustable via iG Keypad• Three Level Password Protection

History Screens

121 125 124A 62kVAr 27 29 29kW 72 73 71A 48kVAr 17 18 16kW 0 0 0A 0 0 0kW 0 0 0A 0 0 0kW

-15 FINISHED HOUR 07:00:00 16.10.-16 GCB CLOSED-ISLAND 06:23:53 16.10.-17 ENGINE START 06:23:49 16.10.-18 MF-MCB OPENED 06:23:44 16.10.

85kW 1503RPM 0.81L 88C 6.1bar 24.9V 84% 50kW 1495RPM 0.72L 25C 5.3bar 24.7V 87% 0kW 0RPM - 22C 0.0bar 25.8V 87% 0kW ORPM - 22C 0.0bar 25.8V 87%

M 0 0 0V 0.0HzG233 227 229V 50.1HzM 0 0 0V 0.0HzG230 228 223V 49.8HzM 0 0 0V 0.0HzG 0 0 0V 0.0HzM190 195 201V 48.7HzG 0 0 0V 0.0Hz

• History Events Can be Viewed From iG Screens as well as WinEdit• Viewed on Multiple Screens

• Adjustable Delay Settings• Five Protective Actions

– Warning– Slow stop – Shut-down – Unloading – History Record

• Reset Function (Horn + Flashing Light)

Protection Handling

Protections• Generator / Utility Over / Under Voltage and Frequency• Voltage and Current Asymmetry• OverCurrent• OverLoad• Excitation Failure• Earth Fault• Oil Pressure (two level: warning, shutdown)• Coolant Temp. (three level: low temp warning, high temp warning, and high temp shutdown) Fuel Level (two level: warning, shutdown)• …

Summary

The InteliGen Offers the Right Solution for the Application.Never Pay for Unneeded Features.

GAC Leaves it up to You to Make the Intelligent Choice!!

Recommended