HABIT v1.2(Control Room Habitability)
Casper Sun, Ph.D., CHP, FHPS
Radiation Protection Branch,
Division of System Analysis
Kevin Lam, System Engineer
Lockheed Martin
February 25 , 2015
1Prepared for brown-bag presentation for HABIT project.
User-Need: NRO-2011-007
• HABIT Code Update and Evaluation RES COR – Casper Sun (RES/DSA/RPB) NRO TL – Syed Haider (NRO/DSRA/SBCV)
• On-going actions include: Phase 1: Re-hosting HABIT to Windows 7
- Lockheed Martin (30 W. Gude Drive, Rockville)
- HABIT V1.2 available and TRM in progress
Phase 2: Implementing ACRS recommendations
- Add DEGADIS and SLAB to HABIT code.
NUREG/CR-6210 (1996) Abstract • Mentioned HABIT (Computer Codes for
Evaluation of Control Room Habitability) is an integrated FORTRAN modules that are used for determining control room (CR) habitability as risk of CR personnel in the event of an accidental release of toxic chemicals or radioactive materials
• Discussed the theoretical basis and physical assumptions made by each of the modules in HABIT and gives detailed information about the data entry windows. Three sample runs are given for each of the modules. A brief section of programming notes is included, including input and output files for the sample runs.
4
What’s New in the HABIT v1.2
• FORTRAN Modules recompiled using latest 64-bit Intel Visual FORTRAN compiler for compatibility with Windows 7 (64-bit)– Computation code is functionally the same as old
FORTRAN modules
• New Graphical User Interface (GUI) developed using Microsoft .NET technology– Consistent module interface design (tabs)– Tighter integration amongst modules and interface– Deployable and Runnable on Windows 7 Environment– Section 508 Compliance (muted use of color, JAWS
accessibility)
5
Examples screens from HABIT v1.2 GUI
6
Examples screens from HABIT 1.2 GUI
Examples screens from HABIT v1.2 GUI
8
HABIT v1.2: Working with Designs
• Designs can be created from scratch or imported from HABIT v1.1 Design Packages
New Design From Scratch Imported Design
9
HABIT v1.2: Working with Designs
Selecting Modules included in the Design
– Modules are selected from the Main Window
– Main Window displays relationships amongst modules
– Main Window displays whether a module is included in the design and whether its been run
– Each included module has its own tab
HABIT v1.2: TOOLTIPS Entering Module Variables • Tooltips provide a convenient way to see the expected range
for fields and provide validations prevent entering bad data
Valid Range Tooltip
Validation Error
Range Validation Warning Required Field Warning
HABIT v1.2: Working with Designs
• Saving Designs– Designs can be saved through the Design Menu
– Saving a design saves the input for all modules within the design (no need to save input for individual modules)
– User is prompted to save design upon exiting system
– Previously saved design is automatically loaded the next time HABIT v1.2 is opened
12
HABIT v1.2: Working with Designs
• Running Modules– Entered variables are inputted into respective
FORTRAN code and generated output is stored in the Design Package’s respective directory
– Designs are automatically saved when running a module
– FORTRAN logging is displayed on the Output Log tab
– If a dependency exists between modules (i.e EXTRAN, CHEM), system alerts user.
HABIT v1.2: Demo A
• Import HABIT v1.1 Design• Hypothetical railroad chlorine tank
car rupture to demonstrate use of EXTRAN and CHEM
HABIT v1.2: Demo BEnter from Scratch• Sample Problem #1 : Simple Release from NUREG/CR-6210
Sup. 1 (TACT5 Example)
User-Need: NRO-2011-007Work-in-Progress
15
• Add SI units• Add ICRP 60/103 dose
coefficients • Add chemicals • Preform HABIT V&V• Add HABIT V1.2 User Manual• Apply TRM
Future Enhancements
• Use REAL*8 in FORTRAN codes to increase the internal precision of computation from current 7 to 15 digits
• Improve visualization of FORTRAN output files in GUI and can be easily importable into Excel©
• Improve FPFP_2 Node Graphs •
• Provide ability to create and modify Nuclide Databases (dose coefficients) directly in GUI
• Renew NUREG/CR-6210.
Questions?
Recommended