View
216
Download
0
Category
Preview:
Citation preview
Our product is your competitiveness
www.nuovaray.it
Devices for
FITNESS, SPORT & WEALTH
3
5
6
9
10
ww
w.n
uo
va
ray.it
EM.T34T3.3M0
TITANIUM Head for facial treatement
Cylindrical body
Diameter: 34 mm.
Height: 100 mm.
Emitting part : TITANIUM
Body : black delrin.
Treatment frequency: 3 MHz
EM.T34A3.3M0
Head for facial treatement
Cylindrical body
Diameter: 34 mm.
Height: 100 mm.
Emitting part: anticorodal aluminium
Body : black delrin.
Treatment frequency: 3 MHz
EM.T55A0.XXX
Head for "massage therapy" and for fixed positioning
Cylindrical body
Diameter: 70mm(contact part 55mm)
Height: 20mm
Emitting part: anticorodal aluminium
Body: black delrin
Treatment frequency: 1; 1,5 MHz
EM.T55A1.XXX
Head for "massage therapy" and for fixed positioning
Cylindrical body
Diameter: 60mm(contact part 55mm)
Height: 30mm
Emitting part: anticorodal aluminium
Body: black delrin
Treatment frequency: 1; 1,5 MHz
3
ww
w.n
uo
va
ray.
it
4
EM.T55A2.1M0
Head for "massage therapy"
Cylindrical body
Diameter: 70mm(contact part 55mm)
Height: 20mm
Emitting part: anticorodal aluminium
Body: black delrin
Treatment frequency: 1 MHz
EM.T55A4.XXX
Head for "massage therapy"
Cylindrical body
Diameter: 33mm(contact part 55mm)
Height: 128mm
Emitting part: anticorodal aluminium
Body: black delrin
Treatment frequency: 1; 1,5 MHz
EM.T60A4.XXX
Head for "massage therapy"
Cylindrical body
Diameter: 33mm(contact part 55mm)
Height: 128mm
Emitting part: anticorodal aluminium
Body: black delrin
Treatment frequency: 1; 1,5; 2 MHz
Upon request it is possible to personalize emitting heads by customer design.
All our heads are marked with an identification code for the traceability of the product
Conform to uni 10681/2010 (standard for decorative and protective material)
ww
w.n
uo
va
ray.it
ww
w.n
uo
va
ray.
it
new
EM.T73R5.XXX
Red light head for "massage therapy"
Cylindrical body
Diameter: 33 mm
Height: 133 mm
Emitting part: anticorodal aluminium
Body: black delrin
Treatment frequency: 1; 1,5; 2 MHz
PHOTOSTIMULATION
(RED):direct to fibroblasts, strengthens and restructures the skin. Delivered in synergy
with ultrasound increases the tonicity and elasticity of the tissues.
EM.T73G5.XXX
Yellow light head for "massage therapy"
Cylindrical body
Diameter: 33 mm
Height: 133 mm
Emitting part: anticorodal aluminium
Body: black delrin
Treatment frequency: 1; 1,5; 2 MHz
PHOTODETOXIFICATION
(YELLOW):
detoxifying and draining action on the tissues; useful in the treatment of cellulite.
EM.T73B5.XXX
Blue light head for "massage therapy"
Cylindrical body
Diameter: 33 mm
Height: 133 mm
Emitting part: anticorodal aluminium
Body: black delrin
Treatment frequency: 1; 1,5; 2 MHz
PHOTORELAXATION
(blue):
normalizes the fabric, ideal in combination with wellness programs .
new
new
5
6
EM.MT02N.1M0
1 MHz new power module for
ultrasound devices with cavitational
effect for aesthetical use REV.2
EM.MT02N.1M5
1,5 MHz new power module for
ultrasound devices with cavitational
effect for aesthetical use REV.2
specific for aesthetical use
EM.MT02N.3M0
3 MHz new power module for
ultrasound devices
with cavitational effect
for aesthetical use REV.2
EM.MT02N.2M0
2 MHz new power module for
ultrasound devices with cavitational
effect for aesthetical use REV.2
All modules of the REV. 2 were built and assembled in accordance with the provisions of the current regulations regarding:
CEI EN 60601 -2-5: 2000; CEI classification 62-63 – Electromedical appliances-Part 2: Specific safety norms for ultrasound therapy appliances. Document n° TO 703280 A – Job J3419 of 09/04/2007 issued by CELAB Srl (accredited lab). The report is accessible on request at our office.
ww
w.n
uo
va
ray.it
New power module for ultrasound equipment particularly
effective when combined with heads of treatment
AISI 304 stainless steel or titanium
new
ww
w.n
uo
va
ray.
it
EM.MS04N.3M0
3 MHz new power module for
ultrasound devices with cavitational
effect for aesthetical use REV.4
supplied with interface card
EM.NI2C2.N00
7
EM.MS04N.1M0
1 MHz new power module for
ultrasound devices with cavitational
effect for aesthetical use REV.4
supplied with interface card
EM.NI2C2.N00
EM.MS04N.1M5
1,5 MHz new power module for
ultrasound devices with cavitational
effect for aesthetical use REV.4 spe-
cific for aesthetical use supplied with
interface card EM.NI2C2.N00
All modules of the REV. 4 were built and assembled in accordance with the provisions of the current regulations regarding:
CEI EN 60601 -2-5: 2000; CEI classification 62-63 – Electromedical appliances-Part 2: Specific safety norms for ultrasound therapy appliances.
Document n° TO 703280 A – Job J3419 of 09/04/2007 issued by CELAB Srl (accredited lab). The report is accessible on request at our office.
EM.MS04N.2M0
2 MHz new power module for
ultrasound devices with cavitational
effect for aesthetical use REV.4
supplied with interface card
EM.NI2C2.N00
New power module for ultrasound equipment particularly
effective when combined with heads of treatment
AISI 304 stainless steel or titanium
new
8
EM.MA01N.1M0
Self oscillating module for 1 MHz
treatment heads
ww
w.n
uo
va
ray.it
9
EM.S0308.A01
Digital sequencer to pilot 8 SQ8
outputs (from two to eight, in an even
number ,sequential mode)
EM.NI2C2.N00
I2C interface board for series REV 4
power modules
EM.DD02N.N00
Demo board for I2C interface display with a program for series REV 4 modules
The board can interface with all our series REV 4 modules and it can read/write on the module registries through the I2C protocol.
ww
w.n
uo
va
ray.
it
SPECIFICATIONS
Interface with 4-pin connector CONN 3 of the card with the connector CN2 module. Power to the Board through the connector CONN5 with an AC or DC voltage between 8V and 15V indifferent polarity. Showing all functions are alterable at will by rotating clockwise and counterclockwise encoder ENC 1. View through interaction with the interface card cod. EM.NI2C2.N00 the functions rela-ting to:
Operating frequency PWM from 0.033 Hz to 40 kHz. Frequency of start / stop mode SWEEP 100 Hz to 40 kHz. Duty cycle of PWM can be set from 0% to 100% End of panel carrier frequency with Encoder ENC1
through an analog dc from 0 mV to 4096 mV in steps of 1 mV.
SPECIFICATIONS
Power supply: 16/0/16 VAC, 250 mA, 0/24 Vac - 2,5 A - 70 VA Light alloy frame autoradiante of small size mm. 176 x 90 (dimensions including BNC) h = 89 mm Mode of operation:
1. FIXED FREQUENCY (MODE_0) fixed frequency PWM 2. SWEEP SAWTHOOT (MODE_1) frequency sweep with ramp "sawtooth" 3. SWEEP TRIANGLE (MODE_2) Sweep frequency ramp "triangular"
PWM operating frequency adjustable from 0.033Hz to 40Khz Frequencies of START and STOP mode can be set from 1Hz to 60kHz Sweep Duty cycle of the PWM can be set from 0% to 100% Analog output DC 0 mV - 4096 mV adjustable in steps of 1mV
10
MAGNETIC
Portable equipment for
MAGNETOTHERAPY
2004/108/CE (electromagnetic compatibilità )
2006/95/CE ( electric safety/ low power ).
Conform to the relevant legislation: :
Portable device for low frequency pulsed magnetic fields therapy.
This device is particularly suitable for home treatment, especially if it has to
be followed for several hours a day and for long periods.
Magnetic generates a variable square wave ( 6-12-25-50-100 Hz)
of adjustable average intensity ( 20-40-60-80-100 Gauss)
It has two outputs which can pilot a couple of solenoids.
MAIN THERAPEUTIC APPLICATIONS
Recent fractures - consolidation delays - pseudoarthrosis -
localized osteoporosis - degenerate arthropathies (coxartrosi - gonartrosi)
-localized dermatological shapes or surgical wounds.
Ulcere of the inferior limbs.)
TECHNICAL CHARACTERISTICS
Power supply: 230 Vac 50Hz
Absorbed power: 50 W
Top intensity of the magnetic field: 100 Gauss
Medium intensity of the magnetic field: 50 Gauss
Magnetic size: 148 x 190 x 67
Solenoid size: 105 x 90 x 28
Equipment:
A couple of solenoids
1 elastic band with Velcro strap
1 PVC suitcase
Instructions for use with therapy application scheme
ww
w.n
uo
va
ray.it
11
ICE LASER B
Portable equipment for
LASERTERAPY
APPLICATION FIELDS
The radiation Laser I.R. gives results in the treatments of the locomotore system
affections in acute phase (typical sports conditions), post-traumatic situations as
well as neuralgias and woven regeneration (skin and mucosa inflammatory
pathologies).
The more obvious result, from the clinical point ofview, is the reduction of the
painful symptomatology and the recovery of the articular movements as effect
of the strong specific property anti-inflammatory of this radiation Laser.
TECHNICAL DETAILS
Supply: 220Vac - 50Hz
Max power: 30 VA
Cooling system: heat pump “Peltier effect” and natural ventilation.
Effective average power: 20mW (optional: 45mW)
Detector I.R.: Fotodiodo a 904 nm supported by a LED visual control emissions.
Structure: anodized aluminium supported by an optical collimation system.
Size ICE B: 335 X 280 X 125 h mm
Weight: 6,3 kg
Equipment:
1 wired power cable
Transport bag
Protective goggles
Instructions and operating manual
ww
w.n
uo
va
ray.
it
2004/108/CE (electromagnetic compatibilità )
2006/95/CE ( electric safety/ low power ).
Conform to the relevant legislation: :
ICE B is the compact model of the most reliable and absolutely innovative series ICE LASER in the therapeutic field of the semiconductorlaser, thanks to the patented cooling system by means an electronic heat pump said "Peltier effect".
12
LIFE TENS
Portable equipment for
ELECTROTERAPY
The transcutaneous electrical stimulation (TENS) is a technique that
aims to produce an analgesic action by stimulating electrodes placed locally
hyperalgesia points (trigger points) and the areas of radiation of pain
(target areas). Such a method acts facilitating both the filter function exerted
by the spinal cord (gate control) is the liberation of substances morphine
(endorphins) high power analgesic.
TENS devices are widely used to treat the symptoms and treatment of the
additional care of acute pain post-operative and post-traumatic stress.
APPLICATION FIELDS
Bruises, sprains, disc problems, back pain acute or chronic, neuralgia,
neck pain, trigeminal neuralgia to, headaches of any kind, painful disease by
repetitive microtrauma (sports medicine), herpes zoster, muscle sprains,
rheumatoid arthritis
TECHNICAL DETAILS
Supply: 9VDC by disposable battery
Consumption: 150 m W (15mA IMAX)
Shape and type pulse: positive square-wave with negative spike
Dimension: 110 X 70 X 30 mm
Weight: 160 g
Pulse width: selectable (40-200)μs
Pulse width:40V (40mA /1KΩ)
Frequency (Rate): selectable 1-160Hz
Safety class: internal power source BF type (IEC 601-1/1967)
Equipment:
2 Cables patient connection
4 electrodes 35x45mm
Case for accessories
Instructions for use
ww
w.n
uo
va
ray.it
2004/108/CE (electromagnetic compatibilità )
2006/95/CE ( electric safety/ low power ).
Conform to the relevant legislation: :
TERMS OF WARRANTY
NUOVA RAY ELECTRONICS guarantees its products against any defect in manufacturing ,malfunctioning or breaking of components for 12 months from date of delivery to the customer’s premises .
Only the owner of the order contract will be entitled to the above said warranty ,directly issued by Nuova Ray.
Second or third parties are not entitled to any warranty and they should contact the company which sold them the product for substitution or free repairing of faulty parts.
The product must be returned undamaged,in its original packaging.
Any accessory provided is not included in the terms of warranty
The warranty does not cover parts which shall prove faulty due to :
1)Repair of damage caused by accidents ,improper use or neglicence in the use of the product
2) Repair of products which were damaged by technical repairs carried out by unauthorized or unqualified personnel .In any case, repairs under warranty will not be effected if the Supplier will detect modifications or assembling carried out by the customer without authorization .
3)Repair of damage caused by adverse weather conditions( rain, fires, lightning,etc..)
4)Repair of products which were damaged as a consequence of transportation , wrong installation ,tampering ,transformations due to circum-stances not directly attributable to the functioning of the product..
5)Repair of damages due to wear and tear of parts or components that are naturally subject to rapid wear or accidental breakdown .
This warranty does not cover any event of improper or unsuitable use of the product ;it does not include the cost of transportation, unauthorized check of the product and removal of faulty product ,which will be at the customer’s expense .
It is intended that the customer’s claim for damages may not exceed the value of the product supplied.
The manufacturer accepts no responsibility for any damage which may directly or indirectly derive to people or things , due to lack of complian-ce to all indications stated in the “terms of use “, if present , and particularly the ones concerning installation ,use and maintenance of the pro-duct.
COMPLAINTS
Should the customer detect any faults resulting from design work,manufacturing or employment of materials in the manufacturing of the product ,he must communicate this to the Supplier by registered mail within 8 days of fault detection .
A detailed description of the fault must be provided by the Customer and it must reach the supplier within the above stated terms , otherwise the Customer will not be entitled to the repair of the faulty product under warranty. The supplier commits to carrying out the appropriate inspections on the product in order to verify the groundings of the complaint .Should the complaint be considered well-founded , the supplier commits to carrying out the necessary modifications to solve the signalled problem . Should the complaint prove groundless or not requiring any interven-tion from the Supplier ,he will send the Customer written communication specifying the reasons for not accepting the complaint and it will be dismissed.
FINAL DISPOSITIONS
The entire text reported so far represents the only valid warranty : nobody is authorized to modify its contents and terms either verbally or in written form
GENERAL SALES CONDITIONS
DELIVERY
The goods always travels at the buyer’s own risk , even if sold free of carriage . The delivery terms are not binding : any delay in delivery , suspension and cancellation of order shall not entitle anyone to claim for compensation or interest.
RETURNED GOODS
Goods shall not be returned unless previously authorized by Nuova Ray. Under no circumstances shall goods be returned if delivered more than 6 months before. Articles returned prior authorization shall however reach Nuova Ray with a regular delivery note , carriage paid. The warranty only covers the substitution of parts manufactured by Nuova Ray whose faults we recognize to be dependent on improper manufacturing or bad qualità of materials.We accept no responsibility for any accident that may occur for using our products. In any case, in the occrrence of accidents resulting from manufacturing defects , the warranty will be limited to the substitution of the parts we recognize as faulty and any form of compensation will be excluded. Any complaint received after 8 days from receipt of goods will not be taken into account.
CONTROVERSIES
For any controversy the only competent Court will be that of Bologna.
ww
w.n
uo
va
ray.
it
NUOVA RAY S.r.l. - Via Battindarno, 147/a - 40133 Bologna - Italy Tel. +39 051 569393 +39 051 618 39 45 - Fax +39 051 6183647
e-mail: info@nuovaray.it - internet: www.nuovaray.it