A. ALL CONTRACTORS ARE RESPONSIBLE FOR PROVIDING COMPLETE INSTALLATION OF ALL COMPONENTS AND SHALL COORDINATE THEIR SCOPE OF WORK WITH ALL OTHER TRADES PRIOR TO SUBMITTING BIDS TO ENSURE THERE ARE NO MISSING OR DUPLICATE COMPONENTS WITH-IN THEIR SCOPE
B. DO NOT SCALE DRAWINGS. USE INDICATED DIMENSIONS ONLY.
C. SHOULD A CONTRACTOR FIND DISCREPANCIES OR AMBIGUITIES IN OR OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS, OR BE IN DOUBT ABOUT THEIR MEANING, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY.
D. CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON THE JOB DURING CONSTRUCTION LAYOUT AND ADVISE THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PERFORMING ANY WORK.
E. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXISTING CONDITIONS ON-SITE AND ADVISING ARCHITECT OF ANY DISCREPANCIES WITH DEMOLITION OR NEW WORK PLANS PRIOR TO PERFORMING ANY WORK.
F. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY IF ANY UNFORESEEN STRUCTURAL OR UTILITY RELATED ISSUES ARISE DURING DEMOLITION OR EXCAVATION.
G. ALL SPECIFIED ITEMS SHALL BE PROVIDED AND INSTALLED PER MANUFACTURERS WRITTEN REQUIREMENTS
ARCHITECTURAL / CIVIL / STRUCTURAL / INTERIOR DESIGNABONMARCHE CONSULTANTS, INC315 W Jefferson BlvdSouth Bend, IN 46601
ALTERNATE #01- NEW FLOORING, BASE, AND WALL PAINT IN OFFICE 120 & OFFICE 110A
ALTERNATE #02- REPLACE ACOUSTIC WALL PANELS ON WEST WALL OF BAND REHEARSAL 110
ALTERNATE #03- NEW QUIET BARRIER WALLS AROUND ENTIRE BAND REHEARSAL 110
ALTERNATE #04- REPLACE RECESSED LOCKERS IN BAND REHEARSAL 110
ALTERNATE #05- NEW LVT FLOORING, RISERS, AND NOSING MATERIALS IN BAND REHEARSAL 110
PR
OJEC
T:SH
EET
TITL
E:
MODELED BY:
DESIGNED BY:
PM REVIEW:
QA/QC REVIEW:
DATE:
SEAL:
SIGNATURE:
DATE:
SCALE:
UNLESS NOTED OTHERWISE
ACI JOB #
SHEET NO.
HARD COPY IS INTENDED TO BE24" x 36" WHEN PLOTTED
SCALE(S) INDICATED ANDGRAPHIC QUALITY MAY NOT
BE ACCURATE FOR ANY OTHERSIZES
T F
Fo
rt W
ayn
e
Be
nto
n H
arb
or
Ma
nis
tee
So
uth
Ha
ve
n
ABO
NM
ARC
HE
Eng
ine
erin
g, A
rch
itec
ture
, La
nd
Su
rve
yin
gC
OP
YR
IGH
T 2021 -
AB
ON
MA
RC
HE C
ON
SU
LTA
NTS
, IN
C.
ab
on
ma
rch
e.c
om
Go
she
n
Ho
ba
rt
Lafa
ye
tte
So
uth
Be
nd
Va
lpa
rais
o
31
5 W
JEFFER
SO
N B
LVD
So
uth
Be
nd
, IN
46
60
1
57
4.2
32
.87
00
57
4.2
51
.44
40
PROJECT ADDRESS
GENERAL NOTES
PROJECT INFORMATION THERMAL
SHEET INDEX
PERSPECTIVE VIEW
PROJECT TEAM VICINITY MAP
BUILDING CODE INFORMATION
LOCATION MAP ALTERNATES
C:\U
sers
\cm
ielc
are
k\D
ocum
ents
\21-1
403 -
MH
S A
coustics_C
EN
TR
AL_cm
ielc
are
k.r
vt
MIS
HA
WA
KA
HIG
HSC
HO
OL
AC
OU
STI
C R
EN
OV
ATI
ON
S120
2 L
INC
OLN
WA
Y E
AST
MIS
HA
WA
KA
, IN
46
544
TITL
E S
HEET
21-1403
T1.1
CMM
MDN
09/21/2021
ARD
ARD
ACOUSTIC RENOVATIONS
MISHAWAKA HIGH SCHOOL
MISHAWAKA, IN
1202 LINCOLNWAY EASTMISHAWAKA, IN 46544
TITLE SHEETS
T1.1 TITLE SHEET
DEMOLITION DRAWINGS
D1.1 FIRST FLOOR - DEMOLITION PLAN
ARCHITECTURAL DRAWINGS
A1.1 FIRST FLOOR - CONSTRUCTION PLAN
A1.2 SECOND FLOOR - CONSTRUCTION PLAN (FORCOORDINATION)
A2.1 FIRST FLOOR - REFLECTED CEILING PLAN
A3.1 INTERIOR ELEVATIONS
A5.1 BUILDING SECTIONS & DETAILS
A9.1 FINISH PLAN
BUILDING CODE
ENERGY CODE
PLUMBING CODE
MECHANICAL CODE
ELECTRICAL CODE
ADA
2014 INDIANA BUILDING CODE
2010 INDIANA ENERGY CONSERVATION CODE
2012 INDIANA PLUMBING CODE
2014 INDIANA MECHANICAL CODE
2009 INDIANA ELECTRICAL CODE
2014 INDIANA BUILDING CODE
DESIGN CRITERIA
SEE STRUCTURAL DRAWINGS FOR STRUCTURAL DESIGN CRITERIA
OCCUPANCY E
TOTAL AREA OF CONSTRUCTION 5980
NUMBER OF STORIES 3 + BASEMENT
LINCOLN WAY E
N B
YR
KIT
AV
E
LINCOLN WAY E
N C
ED
AR
ST
E MISHAWAKA AVE
NO. REVISION DESCRIPTION BY DATE
UP
4
5
3
A5.1
1
A5.1
BANDREHEARSAL
110
OFFICE120
PRACTICE112A
MECH.112F
MUSIC LIBRARY112E
MECH.112D
INSTRUMENTSTORAGE
111D
OFFICE111C
MATERIALSTORAGE
111B
STORAGE111A
FACULTYLOUNGE
115
CLASSROOM126
CLASSROOM125
CLASSROOM124
CHORAL/ORCHESTRAREHEARSAL
111
PRACTICE112B
PRACTICE112C
STORAGE110C
PRACTICE113B
PRACTICE113A
PRACTICE113C
OFFICE110A
REPAIR113D
FACULTY DINING114
GIRLS124A
TLT115A
TLT114A
2.42.4
2.4
2.4
2.4
2.4
2.4
2.4
2.5
2.3
2.6
2.1
2.1
2.2
2.2
2.7
2.7
2.8
2.6
A3.1
1
3
A3.1
2.9
2.9
2.9
2.5
2.9
2.9
2.9
2.9
2.9
4
A3.1
A. DO NOT SCALE DRAWINGS - USE WRITTEN DIMENSIONS PROVIDED ONLY.
B. ALL SPECIFIED ITEMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR AS COMPLETE SYSTEMS WITH ALL ACCESSORY ITEMS REQUIRED FOR A COMPLETE INSTALLATION. GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH ALL TRADES, CONSTRUCTION TYPES, ETC…TO PREVENT EXCLUSION OR DUPLICATION. GENERAL CONTRACTORS BIDS SHALL BE ALL INCLUSIVE.
C. CONTRACTOR SHALL FIELD VERIFY ALL DOOR SIZES.
D. CONTRACTOR SHALL FIELD VERIFY ALL FACETED WALL DIMENSIONS.
E. ALL EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS TEMPORARILY REMOVED, SHALL BE CLEANED AND REINSTALLED.
F. ALL EXISTING WALL DEVICES (OUTLETS, SWITCHES, ETC) SHALL BE RELOCATED TO NEW WALL SURFACES.
GENERAL NOTES - DEMO
PR
OJEC
T:SH
EET
TITL
E:
MODELED BY:
DESIGNED BY:
PM REVIEW:
QA/QC REVIEW:
DATE:
SEAL:
SIGNATURE:
DATE:
SCALE:
UNLESS NOTED OTHERWISE
ACI JOB #
SHEET NO.
HARD COPY IS INTENDED TO BE24" x 36" WHEN PLOTTED
SCALE(S) INDICATED ANDGRAPHIC QUALITY MAY NOT
BE ACCURATE FOR ANY OTHERSIZES
T F
Fo
rt W
ayn
e
Be
nto
n H
arb
or
Ma
nis
tee
So
uth
Ha
ve
n
ABO
NM
ARC
HE
Eng
ine
erin
g, A
rch
itec
ture
, La
nd
Su
rve
yin
gC
OP
YR
IGH
T 2021 -
AB
ON
MA
RC
HE C
ON
SU
LTA
NTS
, IN
C.
ab
on
ma
rch
e.c
om
Go
she
n
Ho
ba
rt
Lafa
ye
tte
So
uth
Be
nd
Va
lpa
rais
o
31
5 W
JEFFER
SO
N B
LVD
So
uth
Be
nd
, IN
46
60
1
57
4.2
32
.87
00
57
4.2
51
.44
40
C:\U
sers
\cm
ielc
are
k\D
ocum
ents
\21-1
403 -
MH
S A
coustics_C
EN
TR
AL_cm
ielc
are
k.r
vt
MIS
HA
WA
KA
HIG
HSC
HO
OL
AC
OU
STI
C R
EN
OV
ATI
ON
S120
2 L
INC
OLN
WA
Y E
AST
MIS
HA
WA
KA
, IN
46
544
FIR
ST
FLO
OR
-D
EM
OLI
TIO
NPLA
N
21-1403
D1.1
CMM
MDN
09/21/2021
ARD
ARD
SCALE: 1/8" = 1'-0"A3.1
DEMOLITION PLAN - FIRST FLOOR1
KEYNOTES - DEMO D1.1KEYNOTE DESCRIPTION
2.1 * ALTERNATE 04 - REMOVE EXISTING LOCKERS.
2.2 REMOVE EXISTING FABRIC WALL PANELS.
2.3 * ALTERNATE 05 - REMOVE EXISTING VCT FLOORING, STAIR NOSINGS AND RISERMATERIAL.
2.4 REMOVE EXISTING DOOR. EXISTING DOOR FRAMES TO REMAIN.
2.5 REMOVE AND SALVAGE EXISTING SUSPENDED CEILING CLOUD, INCLUDINGCEILING TILES, LIGHT FIXTURES, ACOUSTIC INSULATION, FOR REINSTALLATION.REFER TO SHEET A2.1 FOR MORE INFORMATION.
2.6 * ALTERNATE 01 - REMOVE EXISTING CARPETING.
2.7 REMOVE EXISTING TRACK LIGHTING IN ITS ENTIRETY.
2.8 REMOVE EXISTING MICROPHONE IN ITS ENTIRETY.
2.9 REMOVE & SALVAGE EXISTING SUSPENDED LIGHT FIXTURES FOR REINSTALLATION.REFER TO SHEET A2.1 FOR MORE INFORMATION.
NO. REVISION DESCRIPTION BY DATE
UP
A. DO NOT SCALE DRAWINGS - USE WRITTEN DIMENSIONS PROVIDED ONLY
B. ALL SPECIFIED ITEMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR AS COMPLETE SYSTEMS WITH ALL ACCESSORY ITEMS REQUIRED FOR A COMPLETE INSTALLATION. GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH ALL TRADES, CONSTRUCTION TYPES, ETC…TO PREVENT EXCLUSION OR DUPLICATION. GENERAL CONTRACTORS BIDS SHALL BE ALL INCLUSIVE.
C. CONTRACTOR SHALL FIELD VERIFY ALL DOOR SIZES
D. CONTRACTOR SHALL FIELD VERIFY ALL FACETED WALL DIMENSIONS
E. ALL EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS TEMPORARILY REMOVED, SHALL BE CLEANED AND REINSTALLED.
F. UPON COMPLETION OF BASE BID WALL & CEILING ACOUSTIC ASSEMBLY INSTALLATIONS, GENERAL CONTRACTOR SHALL COORDINATE ACOUSTIC TESTING WITH OFFICE INTERIORS, DAVID LINCOLN, 1415 University Drive Court, Granger, IN 46530, cell 618-477-2082, www.oiplaces.com, Dlincoln@oivista.com
G. PROVIDE SEALANT (AND BACKER ROD AS REQUIRED) BETWEEN ALL DISSIMLAR MATERIALS.
GENERAL NOTES - FLOOR PLAN
4
5
CLASSROOM126
CLASSROOM125
CLASSROOM124
GIRLS124A
FACULTYLOUNGE
115
FACULTY DINING114
TLT114A
TLT115A
REPAIR113DOFFICE
110A
PRACTICE113C
BANDREHEARSAL
110
OFFICE120
PRACTICE112A
PRACTICE112B
PRACTICE112C
PRACTICE113B
PRACTICE113A
MECH.112F
MUSIC LIBRARY112E MECH.
112D
INSTRUMENTSTORAGE
111D
OFFICE111C
MATERIALSTORAGE
111B
STORAGE111A
CHORAL/ORCHESTRAREHEARSAL
111
STORAGE110C
3
A5.1
1
A5.1
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
11
2
110C-A 110C-B
110-B
110-A
111-B
111-A
11
3
8"
8.1
8.1
8.1
9.7
9.7
9.8
9.6
9.6
10.1
10.1
A3.1
1
3
A3.1
12.1
12.1
12.1
12.1
4
A3.1
A. BASE BID: AT CEILING AND UPPER 3FT OF PERIMETER WALLSa. PROVIDE "SOUNDPROOF COW - QUIET BARRIER HD SOUNDPROOFING COMPOSITE AT
EXISTING PERIMETER WALL LOCATIONS AND AT ENTIRE CEILING/STRUCTURE ABOVE.• STC 32
b. PROVIDE USG ENSEMBLE ACOUSTICAL DRYWALL CEILING - SUSPENDED SYSTEM AT ENTIRE CEILING.• CAC 40• NRC 0.80
c. PROVIDE USG SHAFT WALL ASSEMBLY (UL U415) AT UPPER 3FT OF PERIMETER WALLS. • STC 51
B. ALTERNATE #03: AT REMAINDER OF PERIMETER WALLSa. PROVIDE "SOUNDPROOF COW - QUIET BARRIER HD SOUNDPROOFING COMPOSITE AT
EXISTING PERIMETER WALL LOCATIONS FROM FLOOR UP TO 3FT BELOW CEILING/STRUCTURE ABOVE.• STC 32
b. PROVIDE USG SHAFT WALL ASSEMBLY (UL U415) FROM FLOOR UP TO 3FT BELOW CEILING/STRUCTURE ABOVE.• STC 51
GENERAL NOTES - WALL & CEILING TYPES
1 1/4" QUIET BARRIER HD
3" AIR GAP
5/8" TYPE "X" GYP WALL BOARD
2 1/2" MTL CH STUD
1 1/4" QUIET BARRIER HD
4" AIR GAP
1" USG ENSEMBLE HIGH-NRC BACKER PANELS
U415 + QUIET BARRIER
USG ENSEMBLE + QUIET BARRIER
5/8" USG ENSEMBLE FOUR-SIDED TAPER PANELS
USG ENSEMBLE SPRAY-APPLIED FINISH
1" GYPSUM LINER PANEL
1A
CEILING
PR
OJEC
T:SH
EET
TITL
E:
MODELED BY:
DESIGNED BY:
PM REVIEW:
QA/QC REVIEW:
DATE:
SEAL:
SIGNATURE:
DATE:
SCALE:
UNLESS NOTED OTHERWISE
ACI JOB #
SHEET NO.
HARD COPY IS INTENDED TO BE24" x 36" WHEN PLOTTED
SCALE(S) INDICATED ANDGRAPHIC QUALITY MAY NOT
BE ACCURATE FOR ANY OTHERSIZES
T F
Fo
rt W
ayn
e
Be
nto
n H
arb
or
Ma
nis
tee
So
uth
Ha
ve
n
ABO
NM
ARC
HE
Eng
ine
erin
g, A
rch
itec
ture
, La
nd
Su
rve
yin
gC
OP
YR
IGH
T 2021 -
AB
ON
MA
RC
HE C
ON
SU
LTA
NTS
, IN
C.
ab
on
ma
rch
e.c
om
Go
she
n
Ho
ba
rt
Lafa
ye
tte
So
uth
Be
nd
Va
lpa
rais
o
31
5 W
JEFFER
SO
N B
LVD
So
uth
Be
nd
, IN
46
60
1
57
4.2
32
.87
00
57
4.2
51
.44
40
C:\U
sers
\cm
ielc
are
k\D
ocum
ents
\21-1
403 -
MH
S A
coustics_C
EN
TR
AL_cm
ielc
are
k.r
vt
MIS
HA
WA
KA
HIG
HSC
HO
OL
AC
OU
STI
C R
EN
OV
ATI
ON
S120
2 L
INC
OLN
WA
Y E
AST
MIS
HA
WA
KA
, IN
46
544
FIR
ST
FLO
OR
-C
ON
STR
UC
TIO
NPLA
N
21-1403
A1.1
CMM
MDN
09/21/2021
ARD
ARD
SCALE: 1/8" = 1'-0"A3.1
CONSTRUCTION PLAN - FIRST FLOOR1
KEYNOTES - CONST. A1.1KEYNOTE DESCRIPTION
8.1 NEW WOOD DOOR - REFER TO SHEET A8.1 FOR MORE INFORMATION.
9.6 GYPSUM BOARD SHALL RETURN @ OPEN EDGES AND ALL OPENINGS OF PHASETWO WALLS FOR FINISHED LOOK. (TYP)
9.7 NEW CARPET TILES. REFER TO SHEET A9.1 FOR MORE INFORMATION.
9.8 * ALTERNATE 05 - NEW LUXURY VINYL TILE. SEE SHEET A9.1 FOR MOREINFORMATION.
10.1 * ALTERNATE 04 - NEW BAND LOCKERS. LOCKERS SHALL HAVE SOLID FLUSHDOORS WITH INTERIOR ADJUSTABLE SHELVES. COORDINATE KEY REQUIREMENTSWITH OWNER. SEE SHEET A3.1 FOR MORE INFORMATION.
NO. REVISION DESCRIPTION BY DATE
A. DO NOT SCALE DRAWINGS - USE WRITTEN DIMENSIONS PROVIDED ONLY
B. ALL SPECIFIED ITEMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR AS COMPLETE SYSTEMS WITH ALL ACCESSORY ITEMS REQUIRED FOR A COMPLETE INSTALLATION. GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH ALL TRADES, CONSTRUCTION TYPES, ETC…TO PREVENT EXCLUSION OR DUPLICATION. GENERAL CONTRACTORS BIDS SHALL BE ALL INCLUSIVE.
C. CONTRACTOR SHALL FIELD VERIFY ALL DOOR SIZES
D. CONTRACTOR SHALL FIELD VERIFY ALL FACETED WALL DIMENSIONS
E. ALL EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS TEMPORARILY REMOVED, SHALL BE CLEANED AND REINSTALLED.
F. UPON COMPLETION OF BASE BID WALL & CEILING ACOUSTIC ASSEMBLY INSTALLATIONS, GENERAL CONTRACTOR SHALL COORDINATE ACOUSTIC TESTING WITH OFFICE INTERIORS, DAVID LINCOLN, 1415 University Drive Court, Granger, IN 46530, cell 618-477-2082, www.oiplaces.com, Dlincoln@oivista.com
G. PROVIDE SEALANT (AND BACKER ROD AS REQUIRED) BETWEEN ALL DISSIMLAR MATERIALS.
GENERAL NOTES - FLOOR PLAN
4
5
CLASSROOM238
CLASSROOM247
CLASSROOM246
MECH.D202A
CLASSROOM224
OFFICE222
COMPUTERROOM
244
COMPUTERROOM
243EQUIP. STORAGE
239
STORAGE238A
STORAGE240A
CLASSROOM240
CORR.D200
STAIRS009CORR.
D204
JAN.D204A
CORR.D201
CORR.D203
CLASSROOM241
CLASSROOM242
LAB245
WOMENSD207
3
A5.1
1
A5.1
1.1
PR
OJEC
T:SH
EET
TITL
E:
MODELED BY:
DESIGNED BY:
PM REVIEW:
QA/QC REVIEW:
DATE:
SEAL:
SIGNATURE:
DATE:
SCALE:
UNLESS NOTED OTHERWISE
ACI JOB #
SHEET NO.
HARD COPY IS INTENDED TO BE24" x 36" WHEN PLOTTED
SCALE(S) INDICATED ANDGRAPHIC QUALITY MAY NOT
BE ACCURATE FOR ANY OTHERSIZES
T F
Fo
rt W
ayn
e
Be
nto
n H
arb
or
Ma
nis
tee
So
uth
Ha
ve
n
ABO
NM
ARC
HE
Eng
ine
erin
g, A
rch
itec
ture
, La
nd
Su
rve
yin
gC
OP
YR
IGH
T 2021 -
AB
ON
MA
RC
HE C
ON
SU
LTA
NTS
, IN
C.
ab
on
ma
rch
e.c
om
Go
she
n
Ho
ba
rt
Lafa
ye
tte
So
uth
Be
nd
Va
lpa
rais
o
31
5 W
JEFFER
SO
N B
LVD
So
uth
Be
nd
, IN
46
60
1
57
4.2
32
.87
00
57
4.2
51
.44
40
C:\U
sers
\cm
ielc
are
k\D
ocum
ents
\21-1
403 -
MH
S A
coustics_C
EN
TR
AL_cm
ielc
are
k.r
vt
MIS
HA
WA
KA
HIG
HSC
HO
OL
AC
OU
STI
C R
EN
OV
ATI
ON
S120
2 L
INC
OLN
WA
Y E
AST
MIS
HA
WA
KA
, IN
46
544
SEC
ON
D F
LOO
R -
CO
NSTR
UC
TIO
N P
LAN
(FO
RC
OO
RD
INA
TIO
N)
21-1403
A1.2
CMM
MDN
09/21/2021
ARD
ARD
SCALE: 1/8" = 1'-0"A5.1
CONSTRUCTION PLAN - SECOND FLOOR (FOR COORDINATION)1
KEYNOTES - CONST. A1.2KEYNOTE DESCRIPTION
1.1 OUTLINE OF AREA OF CONSTRUCTION BELOW
NO. REVISION DESCRIPTION BY DATE
A. REFER TO ELECTRICAL DRAWINGS FOR ADDTIONAL INFORMATION.
GENERAL NOTES - REFLECTED CEILING PLAN
OFFICE120
PRACTICE112A
MECH.112F
MUSIC LIBRARY112E
MECH.112D
CHORAL/ORCHESTRAREHEARSAL
111
PRACTICE112C
PRACTICE112B
STORAGE110C
PRACTICE113A
PRACTICE113B
BANDREHEARSAL
110
OFFICE110A
PRACTICE113C
REPAIR113D
FACULTY DINING114
TLT114A
TLT115A
FACULTYLOUNGE
115
GIRLS124A
CLASSROOM124
CLASSROOM125
CLASSROOM126
INSTRUMENTSTORAGE
111D
OFFICE111C
MATERIALSTORAGE
111B
STORAGE111A
3
A5.1
1
A5.1
PERIMETER OF CLG CLOUD
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A 1A
1A
1A
9.5 26.1TYP
4
A3.1
PR
OJEC
T:SH
EET
TITL
E:
MODELED BY:
DESIGNED BY:
PM REVIEW:
QA/QC REVIEW:
DATE:
SEAL:
SIGNATURE:
DATE:
SCALE:
UNLESS NOTED OTHERWISE
ACI JOB #
SHEET NO.
HARD COPY IS INTENDED TO BE24" x 36" WHEN PLOTTED
SCALE(S) INDICATED ANDGRAPHIC QUALITY MAY NOT
BE ACCURATE FOR ANY OTHERSIZES
T F
Fo
rt W
ayn
e
Be
nto
n H
arb
or
Ma
nis
tee
So
uth
Ha
ve
n
ABO
NM
ARC
HE
Eng
ine
erin
g, A
rch
itec
ture
, La
nd
Su
rve
yin
gC
OP
YR
IGH
T 2021 -
AB
ON
MA
RC
HE C
ON
SU
LTA
NTS
, IN
C.
ab
on
ma
rch
e.c
om
Go
she
n
Ho
ba
rt
Lafa
ye
tte
So
uth
Be
nd
Va
lpa
rais
o
31
5 W
JEFFER
SO
N B
LVD
So
uth
Be
nd
, IN
46
60
1
57
4.2
32
.87
00
57
4.2
51
.44
40
C:\U
sers
\cm
ielc
are
k\D
ocum
ents
\21-1
403 -
MH
S A
coustics_C
EN
TR
AL_cm
ielc
are
k.r
vt
MIS
HA
WA
KA
HIG
HSC
HO
OL
AC
OU
STI
C R
EN
OV
ATI
ON
S120
2 L
INC
OLN
WA
Y E
AST
MIS
HA
WA
KA
, IN
46
544
FIR
ST
FLO
OR
-R
EFL
EC
TED
CEIL
ING
PLA
N
21-1403
A2.1
CMM
MDN
09/21/2021
ARD
ARD
SCALE: 1/8" = 1'-0"A3.1
REFLECTED CEILING PLAN - FIRST FLOOR1
KEYNOTES - CONST. A2.1KEYNOTE DESCRIPTION
9.5 REINSTALL EXISTING 2x4 LIG ACOUSTICAL GRID AND TILES.
26.1 REINSTALL EXISTING 2x4 TROFFER LIGHT FIXTURES IN EXISTING LOCATIONS.
NO. REVISION DESCRIPTION BY DATE
A. GENERAL CONTRACTOR SHALL COORDINATE ALL MEP COMPONENTS AND REQUIREMENTS WITH MEP DRAWINGS AND SPECS.
GENERAL NOTES - INTERIOR ELEVATIONS
FILLER 1' - 6" 1' - 6" 1' - 6" 1' - 6" 1' - 6" 1' - 6" 1' - 6" FILLER
11' - 0"
7' -
0"
FILL
ER
6' -
7"
4"
SOLID FLUSH DOORS
COORDINATE KEY REQUIREMENTS WITH OWNER
A3.1
2
6' -
8"
4"
FILL
ER
1"
2' -
0"
1"
2' -
2"
1"
2' -
1"
1"
ADJUSTABLE INTERIOR SHELVES
MATCHING TOE KICK
7' -
0"
1' - 6"
3' - 0"
6' -
8"
4"
7' -
0"
4"
MATCHING TOE KICK FINISH 1"
2' -
1"
1"
2' -
2"
1"
2' -
0"
1"
FILL
ER
ADJUSTABLE INTERIOR SHELVES
FIRST FLOOR
0' - 0"
6' -
0"
1 1
/2"
10
1/2
"
9.6
12.1
7' -
0"
EXIST. GLASS BLOCKS
PR
OJEC
T:SH
EET
TITL
E:
MODELED BY:
DESIGNED BY:
PM REVIEW:
QA/QC REVIEW:
DATE:
SEAL:
SIGNATURE:
DATE:
SCALE:
UNLESS NOTED OTHERWISE
ACI JOB #
SHEET NO.
HARD COPY IS INTENDED TO BE24" x 36" WHEN PLOTTED
SCALE(S) INDICATED ANDGRAPHIC QUALITY MAY NOT
BE ACCURATE FOR ANY OTHERSIZES
T F
Fo
rt W
ayn
e
Be
nto
n H
arb
or
Ma
nis
tee
So
uth
Ha
ve
n
ABO
NM
ARC
HE
Eng
ine
erin
g, A
rch
itec
ture
, La
nd
Su
rve
yin
gC
OP
YR
IGH
T 2021 -
AB
ON
MA
RC
HE C
ON
SU
LTA
NTS
, IN
C.
ab
on
ma
rch
e.c
om
Go
she
n
Ho
ba
rt
Lafa
ye
tte
So
uth
Be
nd
Va
lpa
rais
o
31
5 W
JEFFER
SO
N B
LVD
So
uth
Be
nd
, IN
46
60
1
57
4.2
32
.87
00
57
4.2
51
.44
40
C:\U
sers
\cm
ielc
are
k\D
ocum
ents
\21-1
403 -
MH
S A
coustics_C
EN
TR
AL_cm
ielc
are
k.r
vt
MIS
HA
WA
KA
HIG
HSC
HO
OL
AC
OU
STI
C R
EN
OV
ATI
ON
S120
2 L
INC
OLN
WA
Y E
AST
MIS
HA
WA
KA
, IN
46
544
INTE
RIO
R E
LEV
ATI
ON
S
21-1403
A3.1
CMM
MDN
09/21/2021
ARD
ARD
SCALE: 1" = 1'-0"A1.1
INTERIOR ELEVATION - LOCKERS (TYP)1SCALE: 1" = 1'-0"A3.1
CASEWORK ELEVATION - LOCKERS (TYP)2SCALE: 1" = 1'-0"A1.1
CASEWORK SECTION - LOCKERS (TYP)3
SCALE: 1" = 1'-0"A1.1
SECTION DETAIL @ NEW WINDOW SILLS4
NO. REVISION DESCRIPTION BY DATE
FIRST FLOOR
0' - 0"
SECOND FLOOR
117' - 6"
1
A5.1
THIRD FLOOR
131' - 8"
4' - 0"
A5.1
2
13
' - 8
"
14
' - 2
" (F
.V.)
17
' - 6
" (F
.V.)
3' -
0"
16
' - 4
"
PT-2
PT-1
BA
SE B
IDA
LTER
NA
TE #
03
1A
1A
PT-2
PT-1
PT-2
PT-1
FIRST FLOOR
0' - 0"
SECOND FLOOR
117' - 6"
3
A5.1
THIRD FLOOR
131' - 8"
14
' - 2
" (F
.V.)
17
' - 6
" (F
.V.)
3' -
0"
13
' - 8
"
PT-2
PT-1
BA
SE B
IDA
LTER
NA
TE #
03 1
A
1A
PT-3(TYP)
PT-2
PT-1
PT-2
PT-1
SECOND FLOOR
117' - 6"
BA
SE B
IDA
LTER
NA
TE #
03
4' - 0" (F.V.)
3' -
0"
(F.V
.)
9.3
9.4
9.1
9.1
9.2
9.99.5
1A
1A
3"
4"
PT-1
PT-2
9.10
7.1
9.11 9.12
A. GENERAL CONTRACTOR SHALL COORDINATE ALL MEP COMPONENTS AND REQUIREMENTS WITH MEP DRAWINGS AND SPECS.
GENERAL NOTES - INTERIOR ELEVATIONS
PR
OJEC
T:SH
EET
TITL
E:
MODELED BY:
DESIGNED BY:
PM REVIEW:
QA/QC REVIEW:
DATE:
SEAL:
SIGNATURE:
DATE:
SCALE:
UNLESS NOTED OTHERWISE
ACI JOB #
SHEET NO.
HARD COPY IS INTENDED TO BE24" x 36" WHEN PLOTTED
SCALE(S) INDICATED ANDGRAPHIC QUALITY MAY NOT
BE ACCURATE FOR ANY OTHERSIZES
T F
Fo
rt W
ayn
e
Be
nto
n H
arb
or
Ma
nis
tee
So
uth
Ha
ve
n
ABO
NM
ARC
HE
Eng
ine
erin
g, A
rch
itec
ture
, La
nd
Su
rve
yin
gC
OP
YR
IGH
T 2021 -
AB
ON
MA
RC
HE C
ON
SU
LTA
NTS
, IN
C.
ab
on
ma
rch
e.c
om
Go
she
n
Ho
ba
rt
Lafa
ye
tte
So
uth
Be
nd
Va
lpa
rais
o
31
5 W
JEFFER
SO
N B
LVD
So
uth
Be
nd
, IN
46
60
1
57
4.2
32
.87
00
57
4.2
51
.44
40
C:\U
sers
\cm
ielc
are
k\D
ocum
ents
\21-1
403 -
MH
S A
coustics_C
EN
TR
AL_cm
ielc
are
k.r
vt
MIS
HA
WA
KA
HIG
HSC
HO
OL
AC
OU
STI
C R
EN
OV
ATI
ON
S120
2 L
INC
OLN
WA
Y E
AST
MIS
HA
WA
KA
, IN
46
544
BU
ILD
ING
SEC
TIO
NS &
DETA
ILS
21-1403
A5.1
CMM
MDN
09/21/2021
ARD
ARD
SCALE: 1/8" = 1'-0"A1.1
SECTION 2 @ BAND REHEARSAL ROOM3
SCALE: 1/8" = 1'-0"A1.1
SECTION 1 @ BAND REHEARSAL ROOM1SCALE: 1" = 1'-0"A5.1
SECTION @ BAND REHEARSAL ROOM - DETAIL2
KEYNOTES - CONST. A5.1KEYNOTE DESCRIPTION
7.1 BATT INSULATION SHALL BE PROVIDED FULL DEPTH AND FULL HEIGHT (TYP).PRODUCT SHALL BE INSTALLED PER MANUFACTURERS WRITTEN REQUIREMENTS
9.1 QUIET BARRIER HD, MANUFACTURER: xxx, WEBSITE: xxx, PHONE NUMBER: xxx.
9.2 USG ENSEMBLE ACOUSTICAL SUSPENDED GYPSUM CEILING SYSTEM.
9.3 5/8" GYPSUM BOARD
9.4 2 1/2" METAL STUD. PROVIDE SLIP TYPE HEAD JOINT (TYP)
9.5 REINSTALL EXISTING 2x4 LIG ACOUSTICAL GRID AND TILES.
9.9 GYPSUM BOARD SHALL RETURN @ OPEN EDGE OF BASE BID WALLS FORFINISHED LOOK (IF ALTERNATE #03 IS NOT USED).
9.10 1" GYPSUM LINER PANEL
9.11 USG ENSEMBLE SPRAY-APPLIED FINISH
9.12 1" USG ENSEMBLE HIGH-NRC BACKER PANELS
NO. REVISION DESCRIPTION BY DATE
UP
CLASSROOM126
CLASSROOM125
CLASSROOM124
GIRLS124A
FACULTYLOUNGE
115
FACULTY DINING114
TLT114A
TLT115A
REPAIR113DOFFICE
110A
PRACTICE113C
BANDREHEARSAL
110
OFFICE120
PRACTICE112A
PRACTICE112B
PRACTICE112C
PRACTICE113B
PRACTICE113A
MECH.112F
MUSIC LIBRARY112E MECH.
112D
INSTRUMENTSTORAGE
111D
OFFICE111C
MATERIALSTORAGE
111B
STORAGE111A
CHORAL/ORCHESTRAREHEARSAL
111
STORAGE110C
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
11
2
110C-A 110C-B
110-B
110-A
111-B
111-A
11
3
*CPT-1
*CPT-1
LVT-1
3
A3.1
4
A3.1
A. PREP & PRIME ALL SURFACES TO RECEIVE FINISHES PER MFR. REQUIREMENTS
B. PROVIDE TEMPERED GLAZING IN ALL DOORS AS REQUIRED BY CODE
C. COORDINATE KEYING REQUIREMENTS WITH OWNER
D. PROVIDE ROOM IDENTIFICATION SIGNAGE INCLUDING ADA RESTROOM SIGN W/ BRAILLE - SEE REFERENCE SHEET T1.2 FOR MOUNTING REQUIREMENTS
E. NEW SIGNAGE - MATCH EXISTING
GENERAL NOTES - FINISHESDOOR ELEVATIONS
2" VARIES 2"
VARIES
VA
RIE
S(F
.V.)
4"
VA
RIE
S
EXIST.NL-1
DOOR FRAMES
6' - 0"
7' -
0"
SOLID WOODNARROW LITE DOUBLE DOOR
W/ SAFETY GLAZING
EXISTING HOLLOW METAL DOOR FRAME
FL-1
7' -
0"
3' - 0"
SOLID WOODFLUSH DOOR
EQ EQ
NL-2
4' - 6"
SOLID WOODNARROW LITE DOUBLE DOOR
W/ SAFETY GLAZING
EQ EQ
7' -
0"
A. CONTRACTOR SHALL REINSTALL EXISTING HARDWARE FROM EXISTING DOORS (TYP). IF HARDWARE IS DAMAGED, CONTRACTOR SHALL PROVIDE NEW HARDWARE TO MATCH EXISTING.
B. NEW DOORS SHALL BE SOUND PROOF DOORS
C. PROVIDE SOUND SEAL GASKETING, AND AUTOMATIC DOOR BOTTOMS AT ALL NEW DOORS
D. CONTRACTOR SHALL FIELD VERIFY THAT ALL EXISTING DOOR FRAMES TO REMAIN ARE GROUTED SOLID
GENERAL NOTES - DOORS
DOOR HARDWARESEE SPECIFICATIONS FOR COMPLETE GROUP INFORMATION
GROUP 01 REUSE EXISTING DOOR HARDWARE (CLEAN BEFORE REINSTALLATION)ADD AT ALL NEW DOORS:
- SOUND GASKETING- AUTOMATIC DOOR BOTTOM- SILENCERS
PR
OJEC
T:SH
EET
TITL
E:
MODELED BY:
DESIGNED BY:
PM REVIEW:
QA/QC REVIEW:
DATE:
SEAL:
SIGNATURE:
DATE:
SCALE:
UNLESS NOTED OTHERWISE
ACI JOB #
SHEET NO.
HARD COPY IS INTENDED TO BE24" x 36" WHEN PLOTTED
SCALE(S) INDICATED ANDGRAPHIC QUALITY MAY NOT
BE ACCURATE FOR ANY OTHERSIZES
T F
Fo
rt W
ayn
e
Be
nto
n H
arb
or
Ma
nis
tee
So
uth
Ha
ve
n
ABO
NM
ARC
HE
Eng
ine
erin
g, A
rch
itec
ture
, La
nd
Su
rve
yin
gC
OP
YR
IGH
T 2021 -
AB
ON
MA
RC
HE C
ON
SU
LTA
NTS
, IN
C.
ab
on
ma
rch
e.c
om
Go
she
n
Ho
ba
rt
Lafa
ye
tte
So
uth
Be
nd
Va
lpa
rais
o
31
5 W
JEFFER
SO
N B
LVD
So
uth
Be
nd
, IN
46
60
1
57
4.2
32
.87
00
57
4.2
51
.44
40
C:\U
sers
\cm
ielc
are
k\D
ocum
ents
\21-1
403 -
MH
S A
coustics_C
EN
TR
AL_cm
ielc
are
k.r
vt
MIS
HA
WA
KA
HIG
HSC
HO
OL
AC
OU
STI
C R
EN
OV
ATI
ON
S120
2 L
INC
OLN
WA
Y E
AST
MIS
HA
WA
KA
, IN
46
544
FIN
ISH
PLA
N
21-1403
A9.1
CMM
MDN
09/21/2021
ARD
ARD
SCALE: 1/8" = 1'-0"A9.1
FINISH PLAN - FIRST FLOOR1
2) CONTRACTOR SHALL PROVIDE FULL SCALE MOCK UP SHOWING ALL FINISHES IN PLACE FOR FINAL APPROVAL
1) CONTRACTOR SHALL SUBMIT ALL FINISH SAMPLES TO OWNER AND ARCHITECT FOR FINAL APPROVAL.
NOTES:
CEIL
ING
ACT-1 ACOUSTIC CEILINGTILE
TBD TBD TBD MATCH OWNER STANDARD
LVT-1 VINYL TILE TBD TBD TBD
FLO
OR
ING
CPT-1 CARPET TBD TBD TBD
S&V-1 WOOD VENEER STAIN SHERWIN WILLIAMS MATCH EXISTING WOOD DOOR FINISH
P-3 PAINT SHERWIN WILLIAMS PROMAR 200ACRYLIC LATEX
MATCH EXISTING STEEL DOOR AND FRAME COLOR
P-2 PAINT SHERWIN WILLIAMS PROMAR 200ACRYLIC LATEX
TBD WALLS FROM FLOOR UP TO 3FT BELOWCEILING
WA
LLS
& D
OO
RS
P-1 PAINT SHERWIN WILLIAMS PROMAR 200ACRYLIC LATEX
TBD CLGS/STRUCTURE ABOVE CLOUD, ANDGYP WALLS (AT UPPER 3FT ONLY) -SHOWN AS "BASE BID" ON DRAWINGS
TS-1 TRANSITION STRIP TBD TBD TBD
SN-1 STAIR NOSING TBD TBD TBD
BA
SE &
TR
IM
RB-1 RESILIENT BASE JOHNSONITE STANDARD 4" COVE TBD
TYPE MARK DESCRIPTION MANUFACTURER STYLE PATTERN/COLOR REMARKS
MATERIAL FINISH LEGENDDOOR SCHEDULE
No. ROOM
DOOR PANEL FRAME
HARDWARE SET REMARKSHANDING W x H TYPE CORE MATERIAL FINISH GLAZING TYPE MATERIAL FINISH
110-A 110 BAND REHEARSAL RHR-DBL 6' - 0" x 7' - 0" NL-1 SOLID WOOD STAIN NL EXIST. HM PT-3 GROUP 01 1" INSUL. GLAZING
110-B 110 BAND REHEARSAL RHR-DBL 6' - 0" x 7' - 0" NL-1 SOLID WOOD STAIN NL EXIST. HM PT-3 GROUP 01 1" INSUL. GLAZING
110C-A 110C STORAGE LH 3' - 0" x 7' - 0" FL-1 SOLID WOOD STAIN FL EXIST. HM PT-3 GROUP 01
110C-B 110C STORAGE RH 3' - 0" x 7' - 0" FL-1 SOLID WOOD STAIN FL EXIST. HM PT-3 GROUP 01
111-A 111 CHORAL/ORCHESTRA REHEARSAL RHR-DBL 4' - 6" x 7' - 0" NL-2 SOLID WOOD STAIN NL EXIST. HM PT-3 GROUP 01 1" INSUL. GLAZING
111-B 111 CHORAL/ORCHESTRA REHEARSAL RHR-DBL 4' - 6" x 7' - 0" NL-2 SOLID WOOD STAIN NL EXIST. HM PT-3 GROUP 01 1" INSUL. GLAZING
112 112 HALLWAY RHR-DBL 6' - 0" x 7' - 0" NL-1 SOLID WOOD STAIN NL EXIST. HM PT-3 GROUP 01 1" INSUL. GLAZING
113 113 HALLWAY RHR-DBL 6' - 0" x 7' - 0" NL-1 SOLID WOOD STAIN NL EXIST. HM PT-3 GROUP 01 1" INSUL. GLAZING
ROOM SCHEDULE
RM. NO. ROOM NAME
FLOORING
BASE
NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING BULKHEAD
FINISH REMARKSMATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH FINISH
110 BAND REHEARSAL CONC LVT-1 RB-1 GYP PT-1, PT-2 GYP PT-1, PT-2 GYP PT-1, PT-2 GYP PT-1, PT-2 PT-1 PT-1 *1., *2., *3.
110A OFFICE CONC *CPT-1 *RB-1 - *PT-2 - *PT-2 - *PT-2 - *PT-2 - - *ALTERNATE 01
120 OFFICE CONC *CPT-1 *RB-1 - *PT-2 - *PT-2 - *PT-2 - *PT-2 - - *ALTERNATE 01
* 1. PT-1 @ BASE BID CEILING & WALLS* 2. PT-2 @ ALTERNATE #03 WALLS* 3. PROVIDE STAIR NOSINGS & RISERS