2
ReiGed Diagnostics ReiGed Diagnostics : www.ReiGed-Diagnostics.com [email protected] [email protected] Fully Automatic Biochemistry Analazer -True random acces and direct reading system -With intelligent multitasking soſtware -Perfect self-checking fungtion -Automatic washing and reusable cuvee -Desigh with environmental protection concept -With refrigenerade reagent positions -Option ISE model and bar code system -With most sophisticated and patent tecnology -Probe crash prevention and detection RD-240 DEPKES RI : AKL 10102901937

Rd 240

  • Upload
    gerobag

  • View
    414

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Rd 240

ReiGedDiagnostics

ReiGed Diagnostics :[email protected] [email protected]

lly A

utom

atic

Bio

chem

istr

y A

nala

zer

-True random acces and direct reading system-With intelligent multitasking software-Perfect self-checking fungtion-Automatic washing and reusable cuvette-Desigh with environmental protection concept-With refrigenerade reagent positions-Option ISE model and bar code system-With most sophisticated and patent tecnology-Probe crash prevention and detection

RD-240

DEPKES RI : AKL 10102901937

Page 2: Rd 240

ReiGedDiagnostics

ReiGed Diagnostics :[email protected] [email protected]

-Operation : Trully Random Access-Reading system : Direct reading system-Assay type : Endpoint, Kinetic, Fixed time, Differential, Blanking, Bichromatic, and Immunoturbidimetric, 1-2 reagent assays and all users programmable-Trough put : 240 test/hr (1reagent),440 test/hr 2 reagent-Sample Volume : 60 sample position including standard,control and stat, Eigther serum cup or primery tube available-Sample volume : 1-100uL, o,1uL/step-Reagent position : 40 refrigenerate reagent positions-Reagent volume : 1-400uL,1uL/step-Reagent needle : With liquid level sensor-Minimum reaction v0lume : 180uL-Reaction time :0-999second-Reaction temperature : 37⁰C+0.1⁰C-Cuvette :90 high-quality UV - tranmitted plastic cuvetts-Washing : 8 chanel automatic washing system for reading cuvetts and for each samp[le/ regent probe equipped with independent washing station-Calibration : Linearity and nonlinearity multipoint calibration-Sample dilution/retest: When the result out of range or the sample is insufficient, the sample may be diluted and retest automaticallly: Or program retes in advance-Wavelenggth range : 300-800nm-Wavelength : 8 measuring Wavelength,more wavelength on request-Width of band= + 2nm_Light source : Long life halogen lamp-Photometric measuring range : 0-3.000 O.D.-Start test : Allowed at any time-Mixing Function : Yes-Stiring probe: 1-Quality control: Q.C processing randomly, and Q.C data may be displayed and printer at any time and stored for years. 3-6 level of Q.C may be runned at the same time-Software : The color interface of soft ware friendly with different language vertions, Windows XP/200 make the equipment more effective and easier to operate-Data processing : more than 200 assay methods and one million patients data may be stored for along time-Option accesories : ISE unit: Floor standing cabinet: Bar code reader for reagent and sample : Quartz cuvvette-Report format : 4 formats-Power supply : 110-220 V/50-60 Hz-Dimention : 130 cm x 100 cm x 85 cm-Weight : 90Kg

SPECIFICATION OF RD-240