12
Copyright 2012 Bruker Corporation. All Rights Reserved. Chemical and Applied Markets Introducing the EVOQ LC-Triple Quadrupole The New Game Changing LC Triple Quad from Bruker Bradley Duruttya

05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Embed Size (px)

DESCRIPTION

5 minutes of fame

Citation preview

Page 1: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Introducing the EVOQ LC-Triple Quadrupole

The New Game Changing LC Triple Quad from

Bruker

Bradley Duruttya

Page 2: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Introducing the EVOQ LC-TQ

EVOQ QubeTM

EVOQ Elite

• Bruker Triple Quadrupole MS• VIP Heated-ESI• Active Exhaust• IQ Dual Ion Funnel• PACER Software• Mass Range: 10-1250 amu

• Bruker Analytical LC• Advance HPLC (8000 psi)• Advance UHPLC (15000 psi)• Advance UHPLC with OLE (15000 psi)

Page 3: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

One Mission

EVOQ was designed for a singular purpose – to reliably quantify thousands of real samples in the fastest ‘sample-to-report’ time possible.

Food Testing

Environmental Testing

Toxicology

Discovery PK

Page 4: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Keys to Achieving Mission

Sustained High-Sensitivity• Orifice interface, Active Exhaust, IQ Dual Ion Funnel and VIP-HESI

Increased Capacity through Higher Robustness• High-sensitivity, Flat-tuning IQ Dual Ion Funnel

Fastest ‘Sample-to-Report’ time• Pacer software with Exception Based Data Review

Page 5: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Active Exhaust vs Equine Plasma – NO DIVERT VALVE USED

• 500 equine plasma samples analyzed with four calibration curves, two bracketing, two spread between samples.

• No divergence between calibration curves run before and after samples were run.

Picture of ion source after running 500 equine plasma samples and 4 calibration

curves.

Page 6: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

A Picture is Worth a Thousand Words

Picture of the EVOQ LC-TQ ion source after running 500 equine plasma samples and 4 calibration

curves.

Game-Changing Performance

Stays cleaner maintains Sensitivity

Page 7: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Improved Dual Ion Funnel Design

Inter-laced Quadrupole Dual Ion Funnel• Linear, on-axis design of the IQ dual ion funnel virtually eliminates

instrument-to-instrument tune variability.• IQ dual ion funnel does not require DC; no impact on tuning

parameters after running hundreds of matrix rich samples.• Less tuning, Less cleaning, Less maintenance equals more

robustness and more samples

User benefit provided by Bruker• Effortlessly transfer methods between EVOQ instruments.• Save time by eliminating re-tuning.

Page 8: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Sustained Sensitivity: 5-1000fg Alprazolam in Rat Plasma On Column

5-50fg curve (n=3)

Full Calibration Range

Resp.Factor

EVOQ Elite with Advance HPLC500uL/min LC flow rate 5-90% Acetonitrile (0.1% Formic) in 1.8min C-18, 3u, 2.1x50, ACE column2uL injected

Page 9: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

PACER Software allows Faster Review

Page 10: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

See more on our Microsite

Page 11: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Game Changing Performance for the Business of Quantitation

Page 12: 05 the new game changing lc triple quad from bruker bradley duruttya - bruker daltonics

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Questions

Thank you