6
Structure and material Pump housing Impeller Mouth ring Seal ring Spacer sleeve Bearing External magnet Fluoroplastic Alumina ceramic Fluorubber /1Cr18Ni9Ti Fill Fluoroplastics alloy/Permanent magnet Polyethylene / Permanent magnet Pump housing Impeller Mouth ring Bearing Main shaft Seal ring Media axis socket Spacer sleeve Rotor Stainless cap Bracket External magnet HT200 lined by Fluoroplastics alloy Alumina ceramic Fill Alumina ceramic Fluorubber / Fluoroplastic Fluoroplastic / FeB 1Cr18Ni9Ti Ht200 HT200 NdFeB Pump housing Impeller Impeller nut Mouth ring Seal ring Pump cover Spacer sleeve Rotor Main shaft External magnet Bracket HT200 lined by Fluoroplastic Fill Alumina ceramic Fluorubber HT200 F46/ NdFeB Silicon carbide HT200 NdFeB Ht200 F46/Reinforced carbon fibre 1 2 The products are widely applicable to: petrochemical industry, acid or base making, non- ferrous metal metallurgy, acid-cleaning technique in car-manufacturing, rare earth separation, pesticides, dyes, medicines, papermaking, galvanization, and radio industry, etc. Service temperature: -20 ~100 . Application Magnetic Pump Series Leak-proof design Operating principle Strong and sturdy pump housing No shaft seal. Utilize magnetic coupling indirect driving, which free you from the leak problem and will not contaminate the site. Because the pump's liquid carrying part is made of Fluoroplastic alloy it can continually carry acid, base, or strong oxidizer at any concentration without any damage. In the driving device the initiative magnet junction box is directly installed onto the motor shaft. The pump chamber is totally sealed, and is propelled to rotate by the magnetic impeller on the magnetic coupling indirect driving pump shaft, its structure tight, safe, and energy-saving. Though the liquid-touching part is made of fluoroplastics, the pump enclosure is made of metal, so the pump can sustain the pipe's weight and mechanical shock. Design feature Structure and material Pump housing Seal ring Bearing Impeller Main shaft Thrust plate Spacer sleeve External magnet Fluoroplastic Fluorubber / High-density carbon Fluoroplastic Alumina ceramic High-density carbon Fluoroplastics Permanent magnet Pump housing Auxiliary impeller Seal ring Impeller Main shaft Mouth ring Bearing Gasket Spacer sleeve External magnet Fluoroplastic Fluoroplastic Fluorubber / 45# Steel, Alumina ceramic Alumina ceramic Fluorubber / F46/1Cr18Ni9Ti Permanent magnet Fluoroplastics alloy/Permanent magnet Structure and material WOLONG WOLONG PTFE PTFE PTFE PTFE FEP PTFE FEP PTFE PTFE FEP cast iron FEP PTFE cast iron lining PTFE cast iron

Cqb & zmd

Embed Size (px)

Citation preview

Page 1: Cqb & zmd

Structure and material

Pump housing

Impeller

Mouth ring

Seal ring

Spacer sleeve

Bearing

External magnet

Fluoroplastic

Alumina ceramic

Fluorubber

/1Cr18Ni9Ti

Fill

Fluoroplastics alloy/Permanent magnet

Polyethylene / Permanent magnet

Pump housing

Impeller

Mouth ring

Bearing

Main shaft

Seal ring

Media axis socket

Spacer sleeve

Rotor

Stainless cap

Bracket

External magnet

HT200 lined by

Fluoroplastics alloy

Alumina ceramic

Fill

Alumina ceramic

Fluorubber /

Fluoroplastic

Fluoroplastic

/ FeB

1Cr18Ni9Ti

Ht200

HT200 NdFeB

Pump housing

Impeller

Impeller nut

Mouth ring

Seal ring

Pump cover

Spacer sleeve

Rotor

Main shaft

External magnet

Bracket

HT200 lined by

Fluoroplastic

Fill

Alumina ceramic

Fluorubber

HT200

F46/ NdFeB

Silicon carbide

HT200 NdFeB

Ht200

F46/Reinforced carbon fibre

1 2

The products are widely appl icable to:

petrochemical industry, acid or base making, non-

ferrous metal metallurgy, acid-cleaning technique in

car-manufacturing, rare earth separation, pesticides,

dyes, medicines, papermaking, galvanization, and

radio industry, etc.

Service temperature: -20 ~100 .℃ ℃

Application

Magnetic Pump Series

Leak-proof design

Operating principle

Strong and sturdy pump housing

No shaft seal. Utilize magnetic coupling indirect driving, which

free you from the leak problem and will not contaminate the

site.

Because the pump's liquid carrying part is made of

Fluoroplastic alloy it can continually carry acid, base, or

strong oxidizer at any concentration without any damage.

In the driving device the initiative magnet junction box is

directly installed onto the motor shaft. The pump chamber is

totally sealed, and is propelled to rotate by the magnetic

impeller on the magnetic coupling indirect driving pump shaft,

its structure tight, safe, and energy-saving.

Though the liquid-touching part is made of fluoroplastics, the

pump enclosure is made of metal, so the pump can sustain

the pipe's weight and mechanical shock.

Design feature

Structure and material

Pump housing

Seal ring

Bearing

Impeller

Main shaft

Thrust plate

Spacer sleeve

External magnet

Fluoroplastic

Fluorubber /

High-density carbon

Fluoroplastic

Alumina ceramic

High-density carbon

Fluoroplastics

Permanent magnet

Pump housing

Auxiliary impeller

Seal ring

Impeller

Main shaft

Mouth ring

Bearing

Gasket

Spacer sleeve

External magnet

Fluoroplastic

Fluoroplastic

Fluorubber /

45# Steel,

Alumina ceramic

Alumina ceramic

Fluorubber /

F46/1Cr18Ni9Ti

Permanent magnet

Fluoroplastics alloy/Permanent magnet

Structure and material

WOLONG WOLONG

PTFE

PTFE

PTFE

PTFE

FEP

PTFE

FEP

PTFE

PTFE

FEP

cast iron

FEP

PTFE

cast iron lining PTFE

cast iron

Page 2: Cqb & zmd

CQB16-12-50FCQB15-15-65FCQB20-15-75FCQB25-20-100F

CQB32-20-110F

CQB40-40-100F

CQB50-32-125F

CQB40-40-125F

Applicable model: Applicable model: Applicable model:

1 CQB16-12-50F*0.6 2 8

0.8 1.5 109.0 16×12 2900 0.025 5

2 CQB15-15-65F

3 CQB20-15-75F

4 CQB25-20-100F

5 CQB32-20-110F

*0.8 3.2 16

1 2.8 18

1 7 20

*1.6 7 22

1 10.5 25

*2.5 10.5 28

4 13.5 30

*5.5 13 35

6.0 15×15 2900 0.180 7

6.0 20×15 2900 0.180 8

6.0 25×20 2900 0.370 12

6.0 32×20 2900 0.550 18

6 CQB40-25-120F

7 CQB40-40-100F

8 CQB40-40-125F

9 CQB50-32-125F

10 CQB50-32-125FA

11 CQB50-32-160FA

12 CQB50-32-200FA

13 CQB65-50-150F

14 CQB65-50-160F

15 CQB65-50-180F

16 CQB65-50-160FL

17 CQB65-40-200FA

18 CQB80-65-160FA

19 CQB80-50-200FA

20 CQB100-80-160FL

4 15 36

5.0 40×25 2900 0.750 35*6.3 15 42

8 12 42

4 11 38

5.0 40×40 2900 0.550 20*6 11 43

8 9 45

4 19 35

3.7 40×40 2900 1.1 40*6.5 17.5 42

9 16 40

7 22 28

3.5 50×32 2900 1.5 45*12 20 42

15 19 46

7 22 28

3.5 50×32 2900 2.2 105*12.5 20 42

15 19 46

7 33 30

3.5 50×32 2900 4.0 140*12.5 32 39

15 29 417 52 20

3.5 50×32 2900 7.5 210*12.5 50 31

15 48 35

15 26 40

4.0 65×50 2900 4.0 100 *20 25 48

25 24 52

15 32 38

4.0 65×50 2900 4.0 100 *17.5 32 40

20 29 47

6 37 22

4.0 65×50 2900 5.5 120 *8 36 28

10 33 30

15 33 41

4.0 65×50 2900 7.5 210 *25 32 51

30 29 55

15 51 41

4.0 65×40 2900 11.0 250*25 50 48

30 49 54

35 34 45

4.0 80×65 2900 11.0 285*50 32 60

60 28 52

35 52 50

4.0 80×50 2900 18.5 320*50 50 60

60 45 60

70 34 53

5.0 100×80 2900 18.5 300*100 32 58

120 30 60

3 4

1 2 4 6 8 10

20

15

10

5

3

40-40-125

40-25-12032-20-110

40-40-10025-20-100

20-15-75

15-15-65

m3m /h

H

Q

16-12-50

8 10 15 20 30 50 80 100 120

m

3m /h Q

H

50

30

20

10

50-32-200

65-50-180

50-32-160

50-32-125(L)

65-40-200

65-50-160(L)

65-50-150

80-50-200

80-65-160100-80-160

3m /h m % m mm r/min kw kgNumber Model

Flow rate Pump lift EfficiencyNet positivesuction head Inlet×Outlet

Rotationalspeed Power of motor

Weight of complete machine

Model and parameter

Note: 1. * stands for standard specifications; please choose parameters the same as or similar to what are in the table as much as possible, and if

the parameters are not included in the table, our factory can realize them by improving the impeller.

2. If the status point flow rate is too small, the inlet should be connected to the return pipe, and for more specific information you can

consult the company's technical department.

Performance curve diagram

CQB Magnet Pump (Figure 1)CQB Magnet Pump (Figure 2)

The medium is clear water(20℃) The medium is clear water(20℃)

CQB65-50-160FL(A)

CQB

65

50

160

F

L

A

Model meaning

Centrifugal pump drived by CQB magnet

The pump's inlet diameter is 65mm

The inlet diameter is 50mm

The impeller's norminal diameter is 160mm

It means the long bracket with underplate

It means distinction code

The material of the liquid carrying part is fluoroplastic alloy

Pictures of some products

WOLONG WOLONG

Page 3: Cqb & zmd

5 6

L S P f W T H h a g x

CQB16-12-50F

CQB15-15-65F

CQB20-15-75F

CQB25-20-100F

200 56 80 30 90 71 100 45 24 17 22

290 71 115 40 112 90 125 2056 20 25

316 71 120 55 112 90 138 56 27 20 38

360 80 150 60 125 100 165 63 34 26 49

430

435

510

430

65

50

85

65

60

67

76

60

CQB32-20-110F

CQB40-25-120F

CQB50-32-125F

CQB40-40-100F

200

270

225

200

125

65

65

125

148

175

192

148

115

150

158

115

216

244

268

216

105

113

128

105

120

140

130

130

90 90

100 100

120 100

130 100

65

75

90

100

4-φ13

4- M12

4-φ13

4-φ13

4-φ11

4-φ11

4-φ11

4-φ13

4-φ12

4-φ12

4-φ13

4-φ12

n-φd n-φt n-φD

n-φd n-φt

CQB50-32-125FA

CQB50-32-160FA

CQB50-32-200FA

CQB65-50-160FL

CQB65-40-200FA

CQB80-65-160FA

CQB80-50-200FA

CQB100-80-160FL

950

1025

1040

1180

1305

1420

1035

1255

895

920

990

1130

1160

1160

990

1130

590

590

650

720

730

730

650

720

75

100

90

105

130

130

170

130

80

80

80

80

100

100

80

100

395

390

450

500

480

480

150

485

352

392

440

440

420

440

392

500

212

232

260

260

240

240

232

280

24

24

25

24

24

24

24

24

165

165

165

185

200

200

185

220

125

125

125

145

160

160

145

180

100

100

100

110

145

125

125

160

330

330

380

435

430

430

380

435

140

140

140

150

185

165

165

200

4-φ18

4-M16

4- M16

4- M16

4- M16

8- M16

4- M16

8- M16

4- M16

4-φ18

4-φ18

4-φ18

4- M16

8- M16

8-φ18

8- M16

IMD40-25-165FAIMD50-40-165F

IMD65-50-130FIMD80-65-140F

IMD80-65-140FIMD100-80-180F

Dimension diagram for installation

Table 1:

Model

Applicable model: (For dimension see table 1)

Applicable model: (For dimension see diagram)Applicable model: (For dimension see diagram)

(For dimension see table 2)Applicable model:

CQB50-32-125FA CQB65-40-200FA

CQB50-32-160FA CQB80-65-160FA

CQB50-32-200FA CQB80-50-200FA

CQB65-50-160FL CQB100-80-160FL

Applicable model: (For dimension see table 3)

Table 2:

Model

Table 3:

Model

The IMD series magnetic drive pump is without shaft seal and utilizes the magnetic coupling indirect driving, totally eliminating leakage. The IMD series magnetic drive pump employs separation sleeve made of the state-of-the-art materials and has high-strength mechanical property, eliminating the magnetic eddy current phenomenon of general magnetic pump. The IMD series magnetic drive pump employs the exclusive pull-back structure, and a single person can easily conduct inner inspection and component changing, with no need to disassemmble the pipes, wich greatly helps daily inspection and maintaining work.

Magnetic pump series

Application3 IMD series magnetic pump, flow rate: 1~160 m /h; pump lift:

17~62m, applicable to the carrying of caustic, inflammable, explosible, toxic, or volatile chemical mediums.

Service temperature: -20 ~100 . Idle running is forbidden.℃ ℃

Design feature

Structure and materials

Pump housing seal ring

Impeller

Pump housing mouth ring

Impeller nut

Main shaft

Shaft spacer seal ring

Pump housing

Pump cover

bearing

Rotary assembly

Spacer sleeve assembly

External manget

Bracket

Fluorubber

Fluoroplastic alloy

Silicon nitride

Fill F4

Silicon carbide

Fluorubber

HT200 lined with F46

HT200 lined with F46

Fill F4

F46 /NdFeB

HT200 /NdFeB

HT200

F46 / Reinforced carbon fibere

Pump housing seal ring

Impeller

Pump housing mouth ring

Impeller nut

Main shaft

Shaft spacer seal ring

Pump housing

Pump cover

bearing

Rotary assembly

Spacer sleeve assembly

External manget

Bracket

Pedestal

Fill F4

Fluoroplastic alloy

Silicon carbide

Fill F4

Silicon carbide

Fill F4

HT200 lined with F46

Fluoroplastic alloy

Fill F4

F46 /NdFeB

HT200 /NdFeB

HT200

F46 / Reinforced carbon fibere

HT200

WOLONG WOLONG

Page 4: Cqb & zmd

1 IMD40-25-130FA

2 IMD40-25-140FA

3 IMD40-25-150FA

4 IMD40-25-160FA

5 IMD40-25-165FA

6 IMD40-25-170FA

7 IMD40-25-185F

8 IMD40-25-230F

9 IMD50-40-140F

10 IMD50-40-150F

11 IMD50-40-160F

12 IMD50-40-165F

13 IMD50-32-200F

14 IMD50-32-195F

15 IMD65-50-120

16 IMD65-50-130F

17 IMD65-50-165F

18 IMD65-40-200F

20 21 40

4.0 65×50 2900 5.5 13530 15 50

35 12 50

20 20 45

4.0 65×50 2900 5.5 13530 19 55

35 17 56

20 35 40

4.0 65×50 2900 7.5 14530 33 54

35 30 52

15 52 25

4.0 65×40 2900 11 25 50 37

35 45 42

8 37 23

3.5 50×40 2900 5.5 14015 36 36

20 33 39

8 40 28

3.5 50×40 2900 5.5 14015 39 40

20 36 43

7 52 20

3.5 50×32 2900 7.5 12.5 50 31

15 47 38

5 51 25

3.5 50×32 2900 7.5 7 50 28

10 48 33

0.7 39 25

3.0 40×25 2900 3 851 39 28

2 38 28

4 62 15

3.0 40×25 2900 7.5 1706 60 20

10 57 32

8 28 27

3.5 50×40 2900 5.5 14015 26 40

20 23 41

8 32 25

3.5 50×40 2900 5.5 14015 30 38

20 27 39

4 21 25

3.0 40×25 2900 3 856 20 32

8 18 33

4 27 25

3.0 40×25 2900 3 856 26 32

8 24 33

4 31 25

3.0 40×25 2900 3 856 30 32

8 28 33

4 35 25

3.0 40×25 2900 3 856 34 31

8 32 32

4 37 25

3.0 40×25 2900 3 856 36 29

8 34 30

4 40 25

3.0 40×25 2900 4 906 39 28

8 36 29

7 8

19 IMD80-65-120F

20 IMD80-65-140F

21 IMD80-50-200F

22 IMD100-80-160F

23 IMD100-80-180F

24 IMD125-100-160F

25 IMD125-100-200F

35 19 35

4.0 80×65 2900 11 60 17 51

70 13 48

35 28 35

4.0 80×65 2900 11 60 25 46

70 22 46

35 52 50

4.0 80×50 2900 18.5 50 50 55

60 45 56

60 34 50

5.0 100×80 2900 30 100 32 60

120 27 62

60 42 50

5.0 100×80 2900 30 100 40 60

120 35 62

80 22 50

6.0 125×100 2900 30 120 20 56

140 15 56

100 40 50

6.0 125×100 2900 37 120 37 56

160 32 56

10

20

30

40

50

60

105 15 20 30 40 50 60 100 130 160 200

40-25-230

50-32-200 65-40-20080-50-200

50-40-165

50-40-160

40-25-165

40-25-150

65-50-165

80-65-140

65-50-130 80-65-120

100-80-180

100-80-160

125-100-200

125-100-160

m3m /h

5 15Q

H

Models and Parameters

3m /h m % m mm r/min kw kgModelNumber Flow rate Pump lift Efficiency

Net positivesuction head Inlet×Outlet

Rotationalspeed Power of motor

Weight of complete machine

Models and Parameters

3m /h m % m mm r/min kw kgModelNumber Flow rate Pump lift Efficiency

Net positivesuction head Inlet×Outlet

Rotationalspeed Power of motor

Weight of complete machine

Note: 1. * stands for standard specifications; please choose parameters the same as or similar to what are in the table as much as possible, and if

the parameters are not included in the table, our factory can realize them by improving the impeller.

2. If the status point flow rate is too small, the inlet should be connected to the return pipe, and for more specific information you can consult

the company's technical department.

IMD80-65-140F(A)

IMD

80

65

140

F

A

Model meaning

Centrifugal pump drived by IMD magnet

The pump's inlet diameter is 80mm

The pump's outlet diameter is 65mm

The impeller's norminal diameter is 140mm

The material of the liquid carrying part is fluoroplastic alloy

It means distinction code

The medium is clear water(20℃)

Performance curve diagram

IMD Magnet Pump

WOLONG WOLONG

170Including base

170Including base

300Including base

300Including base

300Including base

335Including base

435Including base

435Including base

660Including base

680Including base

Page 5: Cqb & zmd

165 125 22 140 100 20 4-M16 4-M16

165 125 22 140 100 20 4-M16 4-M16

4- 20

4- 20

185 145 22 150 110 22 4-M16 4- 20

200 160 22 185 145 22 4-M16 4- 204- 18

200 160 22 185 145 22 4-M16 4- 204- 18

200 160 22 165 125 22 4-M16 4- 208- 18

220 180 24 200 160 24 8-M16 4- 258- 18

220 180 24 160 24 8-M16 4- 258- 18

250 210 24 225 180 24 8-M16 4- 258- 18

25

25

40

40

40

40

50

50

50

4- 18

150 110 20 115 85 18 4-M16 4-M12 4- 2025

250 210 24 225 180 24 8-M16 4- 258- 1850

610IMD40-25-130FA 250 70 80 210 160 310 150 150 110 20 115 85 18 4-M16 4-M12 4- 15

610IMD40-25-140FA 250 70 80 210 160 310 150 150 110 20 115 85 18 4-M16 4-M12 4- 15

610IMD40-25-150FA 250 70 80 210 160 310 150 150 110 20 115 85 18 4-M16 4-M12 4- 15

610IMD40-25-160FA 250 70 80 210 160 310 150 150 110 20 115 85 18 4-M16 4-M12 4- 15

610IMD40-25-165FA 250 70 80 210 160 310 150 150 110 20 115 85 18 4-M16 4-M12 4- 15

610IMD40-25-170FA 250 70 80 210 160 310 150 150 110 20 115 85 18 4-M16 4-M12 4- 15

610IMD40-25-185F 250 70 80 210 160 310 150 150 110 20 115 85 18 4-M16 4-M12 4- 15

730IMD50-40-140F 330 70 80 265 212 360 180 165 125 20 150 110 20 4-M16 4-M16 4- 15

730IMD50-40-150F 330 70 80 265 212 360 180 165 125 20 150 110 20 4-M16 4-M16 4- 15

730IMD50-40-160F 330 70 80 265 212 360

180

165 125 20 150 110 20 4-M16 4-M16 4- 15

730IMD50-40-165F 330 70 80 265 212 360

180

165 125 20 150 110 20 4-M16 4-M16 4- 15

730IMD50-32-195F 330 70 90 265 212 365 180 165 125 22 140 100 20 4-M16 4-M16 4- 15

730IMD50-32-200F 330 70 90 265 212 365 180 165 125 22 140 100 20 4-M16 4-M16 4- 15

725IMD65-50-130F 318 95 80 265 212 360 180 185 20 165 125 20 4-M16 4- 154- 18

730IMD65-50-165F 318 95 80 265 212 365 180 145 24 165 125 24 4-M16 4-M16 4- 15

928IMD65-40-200F 410 70 100 290 220 430 230

185

185 145

22

150 110 22 4-M16 4- 154- 18

935IMD80-65-120F 416 70 100 290 220 430 230

200

160

22

185 145 22 4-M16 4- 154- 18

935IMD80-65-140F 416 70 100 290 220 430 230

200

160 22 185 145 22 4-M16

4- 15

4- 18

970IMD80-50-200F 398 70 100 320 240 445 230 160 22 165 125 22 4-M16

4- 15

8- 18

1110IMD100-80-160F 485 95 125 345 280 500 250

200

220 180

24 160 24 8-M16 4- 158- 18

1110IMD100-80-180F 485 95 125 345 280 500 250

220 180

24

200

200 160 24 8-M16 4- 158- 18

1110IMD125-100-160F 490 95 125 345 280 500 250 250 210 24 225 180 24 8-M16 4- 158- 18

730IMD40-25-230F 336 70 100 275 212 370 180 150 110 20 115 85 18 4-M16 4-M12 4- 15

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

725IMD65-50-120F 318 95 80 265 212 360 180 185

145

145 20 165 125 20 4-M16 4- 154- 18

24

25 1110IMD125-100-200F 490 95 125 345 280 500 250 250 210 24 225 180 24 8-M16 4- 158- 18

L S P f W T H h a b e g i j n- t n- d n- q

710

710

950

950

950

950

1090

1090

1090

710

1090

340

340

490

490

490

490

525

525

525

340

525

310

310

440

440

440

440

475

475

475

310

475

425

425

510

510

510

525

595

595

595

425

595

240

240

310

310

310

310

345

345

345

240

345

90

90

100

100

100

100

125

125

125

90

125

745IMD50-32-195F 530

745IMD50-32-200F 530 36

1000IMD65-40-200F 740 5

1000IMD80-65-120F 740 5

1000IMD80-65-140F 740 5

1000IMD80-50-200F 740 5

1170IMD100-80-160F 870 30

IMD100-80-180F 870 30

IMD125-100-160F 870 30

36

745IMD40-25-230F 530 36

2

3

4

5

6

7

8

9

10

11 IMD125-100-200F 870 30

L S P f W T H h a b e g i j n- t n- d n- q

1

B r

200

9 10

4- q

1170

1170

1170

Installation dimension

Without pedestal (Table 1) With pedestal (Table 2)

Table 1

Table 2

ModelNumber

The ZMD series self-priming magnetic pump amply combines the excellent features of both the self-priming pump and the magnetic pump, and it has both the self-priming property and do away with shafting seal, and it utilizes the magnetic coupling indirect driving, totally eliminating leakage. The ZMD series magnetic drive pump employs separation sleeve made of the state-of-the-art materials and has high-strength mechanical property, eliminating the magnetic eddy current phenomenon of general magnetic pump. The ZMD series magnetic drive pump employs the exclusive pull-back structure, and a single person can easily conduct inner inspection and component changing, with no need to disassemmble the pipes, wich greatly helps daily inspection and maintaining work.

Self-priming magneticpump series

Design feature

Application

ZMD series magnetic pump is widely applicable to industries like petrochemicals, non-ferrous metal metallurgy, pesticide, acid and base making, papermaking, acid washing technics, rare earth seperation, galvanization, electronics, etc., and its structure is the most novel among the current magnetic pump varieties. It is highly-efficient, energy-conserving, safe, and practical.

Structure and materials

Pump housing

Pump cover

Impeller front mouth-ring

Pump cover mouth-ring

Impeller nut

Main shaft

Pump mouth-ring

Impeller rear mough-ring

Impeller

Front cover

Outlet flang

Front bearing

Spacer sleeve seal ring

Spacer sleeve assembly

Rotary assembly

Rear bearing

External magnet

Bracket

HT200 lined with

HT200 lined with

Fill

Silicon carbide

Fill

Silicon carbide

Silicon carbide

Fill

Fluoroplastic

HT200 lined with

HT200 lined with

Fill

Fluorubber

/ Reinforced carbon

/NdFeB

Fill

HT200 /NdFeB

HT200

WOLONG WOLONG

FEP

FEPPTFE

PTFE

PTFE

FEP

FEP

PTFE

FEP

FEP

PTFE

Page 6: Cqb & zmd

1 40ZMD-32F

2 50ZMD-32F

3 50ZMD-45F

4 65ZMD-32F

5 65ZMD-45F

6 80ZMD-32F

7 80ZMD-45F

3

6

10

8

15

20

8

12.5

15

20

30

35

20

25

35

35

60

65

35

50

60

34

32

28

34

32

28

49

48

47

34

32

28

45

45

40

34

32

28

46

45

40

16

24

20

25

44

44

21

35

40

40

52

48

40

44

53

50

55

50

38

50

48

3.0

3.0

3.0

3.5

4.5

3.5

4.5

40×25

50×50

50×50

65×50

65×40

80×65

80×50

3

3

3

3

3

3

3

150

180

180

200

200

200

200

2900

2900

2900

2900

2900

2900

2900

4

5.5

7.5

7.5

11

11

18.5

125

180

170

200

290

280

320

*

*

*

*

*

*

*

m3

m /h Q

H

65ZMD-32F

65ZMD-45F

40ZMD-32F 50ZMD-32F

50ZMD-45F80ZMD-45F

80ZMD-32F

50

40

30

20

6 10 15 20 25 30 40 50 60 70

11 12

2

3

4

5

6

7

1

L S P f W T H h a b c e i jn-φdk g n-φtq

40ZMD-32F

50ZMD-32F

50ZMD-45F

65ZMD-32F

65ZMD-45F

80ZMD-32F

80ZMD-45F

756

905

875

903

1110

1180

336

318

354

275

410

412

416

70

95

95

70

70

75

70

215

172

165

145

218

220

225

225

230

185

225

255

265

265

265

240

290

2 9 0

290

212

212

212

190

220

2 2 0

220

510

496

495

450

610

534

330

320

320

270

400

380

φ150

φ165

φ165

φ185

φ185

φ200

φ200

φ110

φ125

φ125

φ145

φ145

φ160

φ160

50

50

65

40

65

80

80

4-φ18

4-φ18

4-φ18

4-φ18

4-φ18

8-φ18

8-φ18

20

20

20

20

20

20

20

φ115

φ165

φ165

φ165

φ150

φ185

φ185

φ85

φ125

φ125

φ125

φ110

φ145

φ145

50

50

50

25

40

65

65

20

18

18

18

18

20

20

4-φ15

4-φ18

4-φ18

4-φ18

4-φ18

4-φ18

4-φ181150 244 245 618 450

3 4 0 2 8 0

4- 15

X

X

90

100

105

98

114

115

120

3m /h m % m mm r/min kw kgm s

Models and Parameters

ModelNumberFlowrate

Pumplift

Effici-ency

Net positivesuction head Inlet×Outlet

Rotationalspeed Power of motor Weight of

complete machine

Note: 1. * stands for standard specifications; please choose parameters the same as or similar to what are in the table as much as possible, and if

the parameters are not included in the table, our factory can realize them by improving the impeller.

2. If the status point flow rate is too small, the inlet should be connected to the return pipe, and for more specific information you can consult

The company's technical department.

Performance curve diagram

The medium is clear water(20℃)

ZMD self-priming magnetic pump

50ZMD-32F

ZMD

50 32

F

Model meaning

The pump's inlet diameter is 50mm

self-priming manetic drive pump

32m The pump lift is 32m.

The material of the liquid carrying part is fluoroplastic alloy

Installation dimension figure

Inlet flange

Outlet flange

Number Model

Notes on the use of ZMC self-priming magnetic pump, FZB self-priming pump

Installation instructions and connection requirementsMake the concrete foundation according to basic dimensions, and simultaneously bury in the foundation bolt. Put the machine assembly on the foundation and make sure the pump is level, then tighten the foundation bolt. The pump should be near the water tank as much as possible.The diameter of the pump's liquid inlet duct should not be larger than what is required, and the length of the liquid inlet duct should not be more than 5m, the smaller the better but also under the requirements. A filter net should be installed at the bottom of the liquid inlet duct, so as to prevent large pellets or litter from entering into the pump housing and damaging the impeller or affecting the pump's running, and the filtering area should be 3 to 4 times larger than the section area of the duct.A value must be installed in the pipeline of the pump's liquid outlet duct to adjust the flow rate, as that the pump works under the specified flow rate, avoiding the inoperation of the pump due to overflowing. The diameter of the liquid outlet duct should not be smaller than what is specified, the larger the better but also under the requirements. The length of the liquid outlet duct must be larger than 1.5 times of the length of the liquid inlet duct, the longer the better if possible.The weight of the liquid inlet and outlet duct should not be relied on the inlet and outlet flanges, and they should be fixed on their own brackets. The connection parts of the liquid inlet and outlet duct should be tight and air-proof, or else the self-priming function and the pump's normal running will be affected.

1.

2.

3.

4.

Directions for use and maintenance instructionsThe transporting of solid particles or easy-to-crystallize mediums by the self-priming magnetic pump is forbidden. It is not permitted to run continuously with the discharge outlet closed, and the lowest flow rate should be kept.While installing ducts, first install the inlet duct, after fill liquid fully install the outlet duct.After installation, plug in the the power and check whether the running of the pump is smooth by the point-action way, and check whether the rotation direction of the electric motor is the same as the change of direction label.Open about one-third of the outlet valve, then start the self-priming pump (by open the valve), after that slowly adjust the outlet valve until the pump reaches the specified flow range.5. When carrying the liquid, the flow rate, pump lift and the self-priming height should be within the specified range, and the margin should not be too large, or else there will be empty-sucking, which will cause the pump to be out of order.There should be no empty-sucking situation while the self-priming pump is running. Once empty-sucking situation occurs, liquid must be conducted before renew self-priming. Therefore, the user must have facilities to control the lowest liquid postion or employ someone to take care of it, so as to prevent the mediums in the water tank from being sucked empty.The self-priming pump cannot carry mediums which will produce many bubbles, and it cannot transport mediums which are mixture of air and liquid.While transporting easy-to-crystallize mediums, if the pump is not in use for some time, the pump chamber should be cleaned, and not crystallized mediums should ramain, so as to prevent damage on the pump when it is started again due to the drystallization; While restart the pump, liquid should be conducted in according to requirements before self-priming.9. When carrying generel no-crystal mediums, if the pump is restarted after a long period of no use, before restarting, it should be check that whether the liquid in the pump is enough. If not enough, fill it fully before self-priming.While the pump is placed liquid level in using or if it replaces the duct pump in using, the air valve or cushion valve should not be attached. If so, discharge the air valve or the cushion valve.The outlet duct of the pump should not be installed with check valve. If so, an air-bleed hole should be placed at the lower end of the check valve.The installation height for self-priming height is as follows: 3m for self-priming in clear water / density of the medium = actual self-priming height.

1.

2.3.

4.

5.

6.

7.8.

9.

10.

11.12.

WOLONG WOLONG

self-absorptiontime

Self-absorptionheight