Upload
apartmentadda
View
5.075
Download
1
Embed Size (px)
Citation preview
I
»<:::'-.
co-.......
kRANTfWATER METER
productAqualllv fromtbebooseI.
AMAN ENGINEERINGWORJtSwhere productselcellD IIDIDIJ-
CI..AS&A & BCIM.HO.1-
An
Winning over the need. .'-
Over aperiodoftime,waterhasemergedasoneoftherarestcommoditiesinIndiaandinsensitiveconsumptioncontinuestoputmorestrainonitandconsequently,lessavailabilityofthispreciousresource.AtAEW,wehadrealizedthisissuethreedecadesbackandcameupwithwinningsolutionstoconserveeachandeverydropofwater,therebyconservingthislife-givingelixirofnature.
We believe in
Total CustomerSatisfactionthroughqualitymeters,serviceandmanagement.
Get in touch with us, now!
HOWWORLD-CLASSKRANTI WATERMETERSAREMADE
Casting excellence
Therawmaterialsusedincastingofbodiesofwatermetersandtheircomponentsaretestedfortheirphysicalandchemicalproperties,beforeusebyqualifiedpersonnel,inawell-equippedlaboratory.
Machining perfection
Themeterbodiesandtheirpartsaremachinedwithcontemporarylathes,capstanandautomaticmachinesviasuitableinstrumentsviz.threadgauges,templets,
micrometersandgaugesforthreaddimension.
Components unequalled
All plasticcomponentsusedinourwatermetersaremadeofsuperiorqualityplastic
granulesandareproducedonstate-of-the-artautomaticplasticinjectionmouldingmachines,whichenhancetheirlifeandquality.
Assembly focus
Assemblingofgears,rollerdrums,pinionandotherplasticcomponentsforinternalmechanismarecarriedoutbywell-trainedpersonnel.
Testing quality
Thereareseparatebenchesformeteringaccuracyofsizes15,20,25,40and50mmwatermeterswithrotameter,quickactionvalvesandpressuregauges.All metersaretestedindividuallyorinseriesasdesiredbythecustomer.
THE TECHNICAL FACTS
Thecoresupport
DesigningdivisionOurdesigningdivisioncomesupwithnewandinnovativedesignsandtechnologies,resultinginnewproducts.ToolRoomdivision
Thetoolroomcreatesnewtoolsanddiestoemergewithpathbreakingconceptsandproducts.
TestingdivisionTest LabsforChemical & PhysicalTesting
QuaUty Controldivision
Ourwatermetersgothroughabatteryoftestsatallstagesofproduction.
IaIm1WATER METER I-~ ('
-~t
KILOLITRES g $!><><
SupposeourreadingonthewaterMeterisgivenabove:
Then 1034 shows KILOLITRES
1034X1000LlTRES (i,e.1KILOLITRE=1000LlTRES=
= 1034000LITRES (1)
NowSecondRedDrumShows[gJ
It Gives2x100= 200litres (2)
And1stRedDrumshows [ID
It Gives5x10=50Litres (3)
AtLastRedNeedleCoincideswith[!J (4)NowAdd1,2,3 and4
1034000200504
1034254------------------
SoTotalReadingoftheMeteris1034254Litres
".~-- '.~~-Jim"5>'- .. C:J ..-., ,Inlet - Outlet
1.Themetershouldbehandledwithcaresoastoavoidjerk orfallwhich
candamageitsperformance.2.Themetershouldbeinstalledinhorizontalpipelineinuprightpositionwith
thehelpofspiritlevelkeepingproperdistanceasmentionedinthelengthofthemeter.
3.Toensurecontinuouspresenceofwater,thelevelofwatershouldbebelowthecommunicationpipelineofinletandoutletside.Thiswillhelpavoidthedamageandoverrunofthemeterincaseofintermittentwatersupplyandsuddenhammerofwater(referfigure).
4. Thelidshouldbekept closedforprotectionandistobeopenedonlywhiletakingreading
5.ExternalStrainermustbeprovidedtoextendthe lifeofthemeter.
SpecificationsofWaterMeterIS:779/94DryDialStraightReadingClass-A&MagneticDriveClass-B-- --
Multi
-,I
B
JetClass-A CutH21
H1
Section.forClass-A
A
I
Cut SectionforClass-B)
Meters areofDryInferentialStraightreadingsize15,20,25,40 &50confirmingtoClass-A&Class-Bof
IS:779/1994WaterMetersandtheirpartsaremadeofselectedmaterialsofhighaccuracy,longduration
andensuredbyperfectmachiningwithmodemandhighprecisionequipmentinourplant.
DimensIOnsThe dimensionsunitinmm
Length
Including NippleA
250290380430470
MeterSize width(Max)B
100
130
170
210
270
15
20
25
40
50
meter PerformanceDataMeterSize Maximum Flow
RateQmax KUHr.
Nominal Flow
RateonKUHr.
15202540
50
3572030
1.52.53.51015
HeadLoss
Notexceeding0.25Kg/Cm2atQn
Notexceeding1Kg/Cm2atQmax
Height (Max) maximumRecordin~in Ki1o-Litres
99999
99999
99999
999999
999999
HI.50-H2.180
H..60 -H2.240
H..65-H2.260
H1.75-H2.300
H..1l5
Min.
-H2.300
RegistrationinLts.Class-A C1ass-B
0.1 0.1
0.1 0.1
0.1 0.1
1 1
1 1
Maximum TestPressure20Kg/Cm2
Working Pressure16Kg/Cm2
TemperatureSuitability
Transitional
45°C
Flow Minimum Starting Flow Metering Acurary
RateQtUHr. RateQrnin InUHr. thelowerregionofnow Intheupperregionofflow
C!ass.A Class-8 Class-A Class-B Qminin (inclusive) toQt(inclusive) Qt(inclusive) toQmax(inclusive)
150 120 60 30 :t5% :t2%250 200 100 50 :t5% :t2%350 280 140 70 :t5% :t2%1000 800 400 200 :t5% :t2%1500 1200 600 300 :t5% :t2%
.
RAW
....
MATERIAL OR CASTING OUTWORD
Therawmaterialsusedincastingofbodiesofwatermetersandtheircomponentsaretestedfortheirphysicalandchemica'pr~lperties,beforeusebyqualified
personnel,inawell-equippedlaboratory. .. ~~,J ~ ~J.. '..~ ~
MACHINING
Themeterbodiesandtheirpartsaremachinedwithcontemporarylathes,capstanandautomaticmachinesviasuitableinstrumentsviz.threadgauges,templets,
micrometers ~andgaugesforthreaddimension. :.:n il
.l. ;.;
T' \" ,..
Ii, . ~,t)t8\
PLASTIC ...COMPONENTS
Allplasticcomponentsusedinourwatermeteraremadeofsuperiorqualityplasticgranulesandareproducedonstate-of-the-Artautomaticplasticinjectionmouldingmachines,whichenhancetheirlifeandquality.
,."- --
'r ._~-'
ASSEMBL Y ,,~..t/' #'- .
Assemblingofgears,rollerdrums,pinionandotherplasticcomponentsforinternalmechanismarecarriedoutbywell-trained
J
personnel.
TESTING
Thereareseparatebenchesformeteringaccuracyofsizes15,20,25,40and50mmwatermeterswithRotameter,quickactionvalvesandpressuregauges.Allmetersaretestedindividuallyorinseriesasdesiredbythecustomer.
~
I
j