O.U.I.TM ULTRASOUND INVERTED OSMOSIS
A D V A N C E D M E D I C A L I N S T R U M E N T S
O.U.I.TM COLORS:Mod.01: WHITE and GOLD
Mod.02: WHITE and BLACK
ULTRASOUND INVERTED OSMOSISADVANCED AESTHETICS – ULTRASOUND INVERTED OSMOSISWITH MEDICAL CERTIFICATION
After years of applied research, AMI has developed O.U.I.™, a device which represents
the evolution of the “Cavitation” concept and introduces O.U.I. (Osmosi Ultrasonica
Inversa, i.e. Ultrasound Inverted Osmosis), a synthesis of AMI’s engineering and
university laboratories’ research for the treatment of localized adiposity.
O.U.I.™ is the result of an important research between private industry and university
laboratories in the field of not invasive technologies for the treatment of body beauty
challenges: the most effective and technologically advanced solution, available today
in aesthetic medicine.
O.U.I.TM
The research evolution in the ultrasound use on human body has allowed
to go over the “cavitation” concept, adding to this phenomenon the
contribution of O.U.I. ULTRASOUND INVERTED OSMOSIS , an innovative
system with ultrasound waves which permits a progressive increase of
cytoplasmic membrane permeability, determining the osmotic outpour of
triglyceride content, with consequent adipocyte loss.
The particular AMI design represents a perfect and harmonious union
between Hi-tech and Italian style, a prestigious and compact device which
contains the most sophisticated technology actually on the market in the
stable cavitation treatment.
Moderate dimensions, operator friendly, easy to transport, are the principal
characteristics that facilitate doctors’ work in medical office.
An easy consulting display, completely touch screen, synthesizes a very
sophisticated software and different and complete working programs in
an essential number of controls.
ULTRASOUND INVERTED OSMOSIS
By the term ULTRASOUND INVERTED OSMOSIS we define the biological and physical phenomenon due to the strength of the ultrasound beam once penetrated into the adipose tissue. This phenomenon, in fact, following the sinusoidal movement of the ultrasonic energy, and then the pressure and decompression components, gives the adipocyte membrane a gradual increase in its permeability and the consequent outpour of triglycerides content.
Beam generating cavitation and penetration into the adipose tissue
Adipometry
Optional bidimensional ecograph for a scientific and proper qualitative and quantitative evalutation of the layer of adipose pannicula.
Adipometer characteristics
- Emission frequency: 2,5 Mhz- Bidimensional ecography- USB connection- Memorization of data and images
O.U.I.TM
O.U.I.TM STATION:Trolley with techno-dynamic design for the device
support, useful, functional and ergonomic with rubber
coated wheels, it facilitates movements occupying a
very limited space.
TECHNICAL CHARACTERISTICS
Supply: 220-240V/100 50-60Hz
Absorbed power: 190VA
Frequency: 33KHz
Elastic working pressure: 6Kpa/cmq. 3W cmq 36.E3 cycles/sec
Output: continuous, swipped
Frequency sweep: 1.600 HZ- 500 HZ
Safety class: Class 1 type BF (IEC 601-1)
Dimensions: L 440mm, P 360mm, H 250mm
Weight: 9 Kg ca.
O.U.I.™ handprobe dimensions: 50mm
O.U.I.™ handprobe power: 3W cmq
Display: color touch screen 14’’ embedded CPU
Device: O.U.I.™ device
Conformity and norms: 89/336/CEE – 73/23/CEE- 93/68/CEE
Norms: CEI 62-39 – CEI 62-24 – EN 55011- EN-3-2 EN 61000-3-3 – EN 550082-1
Classification: Following norm CEI 62-39 Class I –Type BF
THE SOFTWARE
Operator friendly and powerful, it is the most important component of this device and it allows a safe and customizable use for the operator to obtain the best performances from its sophisticated hardware. It has different working levels (from extremely easy to highly articulated parameters).
THE MICROPROCESSORAMI’s research team has developed a very effective processor with an internal development system to coordinate, study and control the physiologicalparameters.
THE HANDPROBESThe particular ergonomics of the handprobe, result of the team work between engineers and orthopaedic operators, allows and effective and optimal grip. The handprobes are available with three different geometrical shapes: flat, concave and convex which allow to work at different depths. They are built in order to resist to solicitations induced by continuous frequency variations during the treatment.
O . U . I . TM
A D V A N C E D M E D I C A L I N S T R U M E N T S
THE CONTINUOUS RESEARCH IS THE REAL SOUL OF OUR COMPANY AND EVERYTHING WE CONCEIVE IN THIS
COMPANY IS THE RESULT OF A PATH THAT, STARTING FROM SURE AND ATTESTED SCIENTIFIC GROUND, IS BASED
ON A PROFESSIONAL AND EMPIRIC CONFIRMATION OF UNQUESTIONABLE INTEGRITY. THE RESEARCH, SEEKING
THE NEW, LOOKING BEYOND THE EDGE AND THE EVIDENCE IS OUR SPIRIT.
Via Collodi n° 4D
40012 Calderara di Reno, Bologna ITALY
T.: 051.726201
F.: 051.725238
www.ami-engineering.it - www.ami-beauty.it
CO
D. 0
07
01
Emed
-20
11