46
DRILLING SEQUENCE G U I D E IS - II active

IS II active implant protocol(Neobiotech)

  • Upload
    kei-lim

  • View
    885

  • Download
    8

Embed Size (px)

DESCRIPTION

Neobiotech implant placement protocol www.neobiotech.co.kr www.neobiotechus.com

Citation preview

Page 1: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

Page 2: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeØ 4.5 10mm fixture will be placed

2

Page 3: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeIncision

3

Page 4: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

1,200 RPM, 30 ~ 45Ncm

Point Lindemann drilling withirrigation

4

Page 5: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

1,200 RPM, 30 ~ 45Ncm

Point Lindemann drilling withirrigation

5

Page 6: IS II active implant protocol(Neobiotech)

D1 D1 : Ø1.2D2 : Ø2.5D2

7

1.3mm0

33.5mm

8.5 10 11.5 13 16.5

D R I L L I N GS E Q U E N C EG U I D E

IS-II activePoint Lindemann drill

Diameter Product nameØ2.5 LDS25

LDSØ

25

6

Page 7: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activePositioning for the initial drilling

7

Page 8: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

1,200 RPM, 30~45Ncm,10mm stopper

Initial drilling(Ø2.2)with irrigation

8

Page 9: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

1,200 RPM, 30~45Ncm,10mm stopper

Initial drilling(Ø2.2)with irrigation

9

Page 10: IS II active implant protocol(Neobiotech)

0

33.5mm

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeInitial drill

Diameter Product nameØ2.2

Ø2.2

TSD22FTS

D22

F

7

1.3mm

8.5 10 11.5 13 16.5

10

Page 11: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeØ 2.2 depth 10mm hole has appeared

11

Page 12: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeChecking the depthwith depth gauge

12

Page 13: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeChecking the path with a parallel pin

13

Page 14: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeTaking radiography (X-ray)

14

Page 15: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeRemoval of the parallel pin

15

Page 16: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

1,200 RPM, 30~45Ncm,10mm stopper

Twist drilling(Ø2.9)with irrigation

16

Page 17: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeØ 2.9 depth 10mm hole has appeared

17

Page 18: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

1,200 RPM, 30~45Ncm,10mm stopper

Twist drilling(Ø3.4)with irrigation

18

Page 19: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeØ 3.4 depth 10mm hole has appeared

19

Page 20: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

1,200 RPM, 30~45Ncm,10mm stopper

Twist drilling(Ø3.9)with irrigation

20

Page 21: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeØ 3.9 depth 10mm hole has appeared

21

Page 22: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

50 RPM, 50Ncm

Profile tapping(Ø4.5) with irrigation

22

Page 23: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeØ 4.5 Tapping has appeared

23

Page 24: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

Ø 4.5 X 10mm, 25~30 RPM,35Ncm

Fixture placementwith contra angle

24

Page 25: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

25

Page 26: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

Initial fixation at the apex isexcellent to both immediate placement and immediateloading

Apex

26

Page 27: IS II active implant protocol(Neobiotech)

2525

Tighten slowly until it reaches 35Ncm

When Implant is being placed w i t h t o r q u e wrench, 35Ncm is suggested with irrigation

27

Page 28: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeConnecting a coverscrew with Ø1.2 hexdriver (by hand)

28

Page 29: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeSuture

29

Page 30: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

1

2

1. Bioseal2. Powerful thread

2 Main Factors for primary fixation duringosseointegration

30

Page 31: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

Bioseal increases marginal sealing of soft tissue therefore minimizes bone loss.

1.

Powerful thread also calledMagic thread, is specially designed to withstand occlusal and lateral forces.

2.

31

Page 32: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeAfter osseointegration,remove the cover screwwith Ø1.2 hex driver(by hand)

32

Page 33: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeConnectinga healing abutment

33

Page 34: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeAfter soft tissue healing,remove the healingabutment withØ1.2 hex driver(by hand)

34

Page 35: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeConnecting solidabutment withØ1.2 hex driver(by hand)

35

Page 36: IS II active implant protocol(Neobiotech)

Connectingtorque ratchet

36

Page 37: IS II active implant protocol(Neobiotech)

Tightening withtorque ratchet(Max. 35Ncm)

Tighten slowly until it reaches 35Ncm

37

Page 38: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeSeating impression cap over the abutment

38

Page 39: IS II active implant protocol(Neobiotech)

Taking impression

39

Page 40: IS II active implant protocol(Neobiotech)

Impression capcomes out withimpression

40

Page 41: IS II active implant protocol(Neobiotech)

Insert abutmentlevel lab analoginto impression

41

Page 42: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeSeating protectivecap over abutmentand fabricatingprovisional restoration

42

Page 43: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeWhen finalprosthesis is ready,remove theprotective cap

43

Page 44: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II activeCementing thefinal restoration

44

Page 45: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

1. Bioseal2. Coronal Macro Thread3. S.L.A. Surface treatment

Characteristics of IS-II active Implant that has long-term stability

1

2

3

45

Page 46: IS II active implant protocol(Neobiotech)

D R I L L I N GS E Q U E N C EG U I D E

IS-II active

IS-II active implant is optimized for maintenance of primary stability with its powerful thread.Soft tissue healing process is predictable due toS.L.A surface treatment composed of macro andmicro pores which allow excellent biosealing.

S.L.A. Surface treatmentBioSeal (0.5mm) Coronal Macro Thread

2.1. 3.