Created by Ahmed Hassaan
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 2
› When we say “ Native Ethernet “ , we mean that source of traffic is
Packets like in data network and there is no conversion between PDH
and Ethernet
› Microwave links should be hybrid links to configure native Ethernet
› Hybrid Microwave handles packets and TDM natively (without mapping
onto another protocol), transporting multimedia traffic efficiently and
allowing operators to launch data services cost-effectively without
impacting traditional TDM services.
Native Ethernet
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 3
Requirements to interface with Ericsson nodes
› LCT software was installed on your laptop as user interface
( You should use latest release )
› Physical cable for connection
( LAN or Mini-USB cable )
› Authorized Account for Access
user name : control_user
password : ericsson
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 4
How to configure Native Ethernet on Ericsson AMM
Ethernet Configuration can be created using one of following
connections :
1- Layer 1 connection
• It connects WAN and LAN interfaces through Layer 1
• It don’t use Ethernet switch ports for connections
• There is no VLAN creation
• It transmits any packet regardless its VLAN ID
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 5
How to configure Native Ethernet on Ericsson AMM
2- Layer 2 connection
• It use Ethernet switch ports for connections of WAN and LAN interfaces
• There is a VLAN creation
• We connect WAN and LAN interfaces via VLANs
• We can control transmission of packets according to its VLAN
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 6
How to configure Native Ethernet on Ericsson AMM
› We will focus on Ethernet configuration using Layer 2 connection
› Layer 2 Connection procedures :
1. Check on packet link capacity in radio link configuration
2. Create new WAN interface for packet link
3. Configure switch mode for Ethernet switch
4. Assign switch port for each LAN or WAN port
5. Configure port role for all assigned switch ports
6. Finally , Create new VLAN then add assigned switch ports
7. Review your configurations using overview windows of Ethernet
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 7
How to configure Native Ethernet on Ericsson AMM Procedure # 1 :
› To start your configurations , you should check that there are a packet
link capacity ≥ 2Mb/s on MW link configuration
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 8
How to configure Native Ethernet on Ericsson AMM Procedure # 2 :
› Create WAN for available packet link capacity using one from RL-IMEs
existing in NPU slot
› Drag and drop packet link from available packet links box to assigned
packet links box
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 9
How to configure Native Ethernet on Ericsson AMM
› After saving last configuration , WAN is created and displayed in WAN
interfaces in drop menu of Ethernet in management tree
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 10
How to configure Native Ethernet on Ericsson AMM
› Following tables show Capacities of RL-IMEs for different types NPU
cards
Table 1 : Capacity of RL-IMEs for NPU3 B and NPU3 C
RL-IME Number Number of RL-IMEs
Number of Packet Links
per RL-IME
RL-IME Capacity
100 1 4 1.6 Gbps
101 1 2 830 Mbps
102 – 104 3 1 500 Mbps
Table 2 : Capacity of RL-IMEs for NPU1 C
RL-IME Number Number of RL-IMEs Number of Packet Links
per RL-IME
RL-IME Capacity
100 – 101 2 4 1.6 Gbps
102 – 103 2 4 830 Mbps
104 – 107 4 2 830 Mbps
108 – 119 12 1 500 Mbps
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 11
How to configure Native Ethernet on Ericsson AMM Procedure # 3 :
› Configure switch mode for Ethernet switch to be “ Customer mode
(802.1Q) “ .
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 12
How to configure Native Ethernet on Ericsson AMM Procedure # 4 :
› Assign switch port number to LAN and WAN ports which need to be
connected via VLAN then switch their Admin Status to be “ Up “
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 13
How to configure Native Ethernet on Ericsson AMM Procedure # 5 :
› Configure port role for each switch port was assigned to WAN or LAN
› For WAN interface , port role will be “ I-NNI “
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 14
How to configure Native Ethernet on Ericsson AMM
› For LAN interface , port role will be “ UNI “
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 15
How to configure Native Ethernet on Ericsson AMM Procedure # 6 :
› Create New VLAN which has planned VLAN ID number and VLAN
name
› Add switch ports which assigned and configured for LAN and WAN
ports to Ports/member field
› Configure Unregistered Multicast to be “ Filter “
› Don’t modify or add any port to Default VLAN
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 16
How to configure Native Ethernet on Ericsson AMM Tagged and Untagged LAN ports
› LAN port can be configured to be tagged or untagged port according to
customer request
› If LAN port will be untagged port
1. Check on configurations of switch port assigned to this LAN port
2. Add switch port to Ports / Untagged in VLAN configurations
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 17
How to configure Native Ethernet on Ericsson AMM Tagged and Untagged LAN ports
› If LAN port will be tagged port
– Simply don’t add its switch port to Ports/Untagged
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 18
How to configure Native Ethernet on Ericsson AMM Procedure # 7 :
› Review your configurations using overview windows of Ethernet and
VLAN
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 19
How to configure Native Ethernet on Ericsson CN210
› Ericsson CN210 supports only one MW link on its indoor equipment
› So it has only one WAN interface and it don’t need to be created as in
case of TN using RL-IME
› You can complete Ethernet configurations starting from configure
Ethernet switch ( Procedure # 3)
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 20
Expected problems appear after configuration
1- WAN operational status is down :
• Check on Admin status of WAN , it should be up
• Check on packet link capacity , it should be ≥ 2Mbit/s
• MW link should be up (i.e. Near End site and Far End site are connected )
• WAN interface in other site was created
• Packet link capacities must be matched in both sites of MW link
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 21
Expected problems appear after configuration
2- LAN operational Status is down :
• Check on Admin status of LAN , it should be up
• Check on physical connection between two LAN ports ( LAN cable has 2 RJ-45
connectors) and two connectors should be installed as straight or crossover
standards
• If LAN still down you can change speed of this port from “ Auto “ to “ Full duplex 1000
Mbit/s “ and check again on status
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 22
Expected problems appear after configuration
3- WAN or LAN ports can’t transmit or receive packets :
• Check on status of all ports participate in connection from source ( RNC ) to
destination ( Node B ) . If there is disconnected port in path , other ports will have
this problem
• Review your configurations on all nodes participate in this connection VLAN ID and Name should be matched in all nodes for this VLAN
VLAN in each node should include all switch ports assigned to WAN and LAN planned for this connection
Each switch port configured with right port role according to its connectivity ( WAN or LAN )
Admin Status and operational status of all ports are “ UP “
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 23
MINI-LINK Craft Wizards
› You can use Mini-link craft wizards to perform a basic configurations
› It is used to create
1- Layer 1 connection
2- Layer 2 connection
› It helps user to avoid any missing step in his configurations
› It generates a summary in final window to review your work
› You can get it by press on Wizards tab in main tool bar of Mini-link
craft
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 24
MINI-LINK Craft Wizards
› After select Layer 2 Connection Wizard from Wizards menu ,
Welcome page will open to start Ethernet configuration
› It will inform you about available configurations
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 25
MINI-LINK Craft Wizards
› Press Next to open Task Selection page , Then read and follow
instructions of window
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 26
MINI-LINK Craft Wizards
› Step #1 help you to configure both LAN and WAN ports
› Select Native Ethernet WAN interface to configure radio link packet link
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 27
MINI-LINK Craft Wizards
› Press Next to open Configure Native Ethernet WAN interface page
› It displays existing WAN interfaces for any modifications
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 28
MINI-LINK Craft Wizards
› Select Create New WAN interface then press next
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 29
MINI-LINK Craft Wizards
› Next page Configure Traffic Capacity is used for select RL-IME for
packet link capacity
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 30
MINI-LINK Craft Wizards
› After Selecting RL-IME , Add radio link packet link capacity
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 31
MINI-LINK Craft Wizards
› Next page shows Dimension Ethernet Capacity
› You can change Ethernet capacity according to total link capacity
› Total link capacity = PDH capacity + Ethernet capacity
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 32
MINI-LINK Craft Wizards
› Next page is summary for previous configurations
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 33
MINI-LINK Craft Wizards
› Press Finish to execute your configurations on WAN interface
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 34
MINI-LINK Craft Wizards
› Press on “ Go To Task Selection Page “ icon to go back to this page
› Now Select LAN interface from Step 1
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 35
MINI-LINK Craft Wizards
› Press Next to display available LAN ports for selection
› Select assigned LAN port for Ethernet connection
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 36
MINI-LINK Craft Wizards
› Next Page shows drop menu of LAN port speed
› Leave its speed on default “ Auto “
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 37
MINI-LINK Craft Wizards
› Next page is summary of LAN port configuration
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 38
MINI-LINK Craft Wizards
› Press Finish to execute your configurations on LAN interface
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 39
MINI-LINK Craft Wizards
› Press on “ Go To Task Selection Page “ icon to go back to this page
› Go to step 2 : Configure Layer 2 Connection
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 40
MINI-LINK Craft Wizards
› Next page displays Switch mode of Ethernet switch
› Select Customer mode and press Next
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 41
MINI-LINK Craft Wizards
› Next page displays existing VLANs for any modifications
› Select Create new Layer 2 Connection
› Add VLAN ID , Name to new VLAN
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 42
MINI-LINK Craft Wizards
› Next page shows all WAN and LAN interfaces in node
› Add assigned WAN and LAN interfaces for this connection to new
VLAN
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 43
MINI-LINK Craft Wizards
› Assign switch port for each inserted interface
› Modify Port role for inserted interfaces
› “I-NNI” for WAN interface and “ UNI “ for LAN interface
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 44
MINI-LINK Craft Wizards
› Next three pages don’t need to be modified , leave it with default
configurations ( Bandwidth profiles , QOS and L2 control protocols )
› Summary page for review your configurations before finishing
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 45
MINI-LINK Craft Wizards
› Press Finish to execute your configurations for creating new VLAN
Ahmed Mohamed Hassaan | Ericsson Internal | Dec-2013 | Page 46
MINI-LINK Craft Wizards
› Now you can check for creation of New VLAN on node